Document oMyaq8Qvw9D8qmb2v4oOq3KRR

\ UNION BUSINESS CONFIDENTIAL INDUSTRIAL HYGIENE MONITORING FOR TO: w. T. Shelton, 704 Shop ASBESTOS Computer Ref. W-1373 Date Sept. 2. 1982 cc: R. E. Peele, 701-334 R. G. Rowe, M.D., 791 PERSON MONITORED ____________________________J. W. Greenlee________________________ Location Bldg. 707, Room 101 Date 07/23/82 PLAINTIFF'S EXHIBIT UC-2507 EXPOSURE RESULTS Sample No. 1 2 3 4 Cone, 2 fibers/cc fibers/ 0.56 cc fibers/ 1.6 cc fibers/ 0.71 cc Sampling Time 2 Hrs. 12 Mins (0904-1114) 2 Hrs. iz Mins" /'non4-m4' 2 Hrs. 21 Mins (1250-1511) 2 Hrs. 21 Mins (1250-1511) Comments Personal sample Area sample - middle of Room 101 Personal sample Area sample - middle of Room 101 5 6 Time-Weighted Average Concentration (TWA) Celling Concentration ALLOWABLE EXPOSURE (8 Hrs . ) TWA 2 fibers/cc Ceiling _______________ X OSHA OSHA JJCC UCC Other ____Other COMMENTS J. W. Greenlee was monitored while stripping old insulation from approximately two hundred feet of steam line in Building 707, Room 101. Mr. Greenlee wore gloves, coveralls and a respirator throughout the duration of the work period. A water spray cannister was used to wet the insulation, however, the exterior of the insulation was so hard that the water did not soak through well. Both entrance ways to Room 101 were barricaded and marked with signs indicating a potential asbestos hazard. Please notify employee of results. WORK BY ________: : ^ -C - ' _________ Mario F. Stowers APPROVED BY Manhar A. Patel UCC 024346 l CONFIDENTIAL INDUSTRIAL HYGIENE MONITORING FOR TO: W. T. Shelton, 704 Shop ASBESTOS HULCOPY Computer Ref. W-1212 Date August 6, 1981 cc: R. E. Peele, 701-334 H. L. Robinson, 701-401 PERSONSMONITORED J. W, Greenlee and D. E. Lawrentz Location Bldg- 707 Cell 11, 2nd Level Date 08/05/81 EXPOSURE RESULTS Sample No. Cone . Fibers 1 0.074 cc Fibers 2 0.04o cc 3 Sampling Time 16 Mins. 15 Mins. Comments Personal sample -J.W. Greenlee Personal sample - D. E. Lawrentz 4 5 6 J.W. Greenlee; <0.074 Fibers Time-Weighted Average Concentration (TWA) D.E. Lawrentz: <0.045 cc Ceiling Concentration - ALLOWABLE EXPOSURE TWA 2 Fibers/cc Ceiling _________________________ X QSHA ____OSHA _____UCC UCC _____Other Other COMMENTS Insulators were monitored while stripping old insulation from about 20 feet of steam line on the second level of Cell 11 in Building 707. Both insulators wore gloves and respirators. Water spray was used to wet the insulation in order to keep the dust down. The fiber concentra tions in the samples taken on both men were found to be considerably less than the allowable exposure of 2 fibers/cc. WORK BY pw- <r. Mario F. Stowers APPROVED BY UCC 024347 Manhar A. Patel .. 4 INDUSTRIAL HYGIENE MONITORING FOR - TO: w. t. Shelton, 704 Shop ASBESTOS RLP "OPY Computer Ref. W1121 CC: G. F. Hurley H. L. Robinson PERSON MONITORED John Hackney, Ralph Hess Location Bldg. 707, Cell 3 Date 10/29/80 EXPOSURE RESULTS Sample 1 2 3 4 5 6 Cone. 3.1 fibers/ zc Sampling Time 56 minutes Comments Sample taken on John Hackney 11.9 56 minutes Sample taken on Ralph Hess 14.9 30 minutes Sample taken on John Hackney Too dense to count. 30 minutes Sample taken on Ralph Hess Time-Weighted Average Concentration (TWA) Ceiling Concentration ALLOWABLE EXPOSURE - TWA Ceiling OSHA OSHA UCC UCC Other Other COMMENTS Samples taken during stripping of Dowtherm lines in Cell 3 of Building 707. The lines were wetted down with water, however the insulation material was very hard on the outside and the water did not soak through very well. Respirators and gloves were used by the persons monitored. Analysis of the insulation material being stripped showed that it was not asbestos. WORK BY VW*, J? APPROVED BY UCC 024348 INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS FILE COPY TO: w. T. Shelton, 704 Computer Ref. 1070 CC: G. F. Hurley H. L. Robinson R. G. Rowe, M.D. PERSON MONITORED Greenlee, J. W Location Bldg. 707, Fourth Level, Date 8/5/80 --B--------- ceil n--------- -------------- EXPOSURE RESULTS Sample 1 2 3 4 5 6 Cone. fibers > .92 5 (im/crn^ Sampling Time 78 mins. Comments Stripping and bagging suspected asbestos containing insulation from approximately 50 feet of i/2-2" steam line. Time-Weighted Average Concentration (TWA) Ceiling Concentration ALLOWABLE EXPOSURE TWA 2 fibers >5 pm/c m Ceiling UCC UCC COMMENTS Other Other UCC 024349 INDUSTRIAL HYGIENE MONITORING FOR ASBESTOS TO: W. T. Shelton, 704 Computer Ref. 1070 CC: G. F. Hurley H. L. Robinson R. G. Rowe, M.D. PERSON MONITORED Raines, R. E. Location Bldg. 707, Fourth Level, Cell 11 EXPOSURE RESULTS Date 8/5/80 Sample 1 2 3 4 5 6 Cone. fibers 1.85 >5 pm/c m*^ Sampling Time 79 mins. Comments Stripping and bagging suspected asbestos contain ing insulation from approximately 50 feet of 1/2 - 2 inch steam line. Time-Weighted Average Concentration (TWA) Ceiling Concentration ALLOWABLE EXPOSURE TWA 2 fibers >5 gm/cm3^OSHA"; Ceiling _______________________ OSHA UCC UCC Other Other COMMENTS Even though the exposure concentration is near the allowable exposure, Mr. Raines wore a disposable 3M dust respirator which would give him further protection. UCC 024350