Document oMbMpExoV3nXxwXOQmq5GBxjw

precast gypsum roof decks Sold through BESTWALL CERTAIN-TEED SALES CORPORATION a modern product gvpsteel plank is a structural, precast roof deck unit. All four sides are bound with a steel framework that is tongued and grooved so that adjacent units lock to form a series of strong, rigid 'T' beams. The gypsum core of each plank contains a steel wire mat. The wide-spread acceptance of Bestwall Gypsteel Plank by architects, engineers and builders is estab lished by the many millions of square feet of Gypsteel now in service all over the Country. Gypsteel Plank is used as a roof decking in industrial, commercial and institutional buildings. IMPORTANT ADVANTAGES 1. quality -- Gypsteel Plank is unsurpassed in quality and uniformity because it is precast under factoryquality control. This feature permits an architect to ex ercise the maximum control over the quality of the fin ished roof deck. 2. ECONOMICS -- (a) Gypsteel Plank is ready to apply when it arrives at the job; no special experience or equipment is necessary for erection. Gypsteel Plank is applied without grout and, therefore, winter time delays are avoided. It may be erected in any weather that men can work. (b> Unlike many roof deck systems Gypsteel Plank does not require a special vapor barrier beneath roof in sulation nor a sprinkler system to obtain a favorable fire insurance rating. (cl Gypsteel Plank is light in weight and structurally well designed. Tills permits the selection of light framing members and allows maximum spacing. Gypsteel has the ability to follow warped surfaces, if not too extreme. I.d) Gypsteel Plank may be laid directly over wood, concrete, or steel supports of any type and of either uniform or variable spacing (not exceeding 1' on centers). End joints must be staggered, but need not come over the supports. This reduces cutting to a minimum and practically eliminates waste, for a small piece left over from the last Plank in any row may be used to start the next row. 3. VERSATILITY -- Gypsteel Plank is adaptable to flat roofs, pitched roofs and curved roofs having a radius of 150 ft. or more. So that Gypsteel Plank may be attached to any steel structural supporting member in ue. there are .special clip; available. The type, including manufacturer and size, of the structural supports to be used should lie given at the time the order for Blank is placed so that proper clips may be furnished. a. stability and durability -- Gypsteel Plank represents an extremely durable and stable product. It is not effected by changes in temperature or atmospheric conditions. It will not rot, decay or deteriorate, it is vermin proof, termite proof, and is as permanent as any structure. In addition, the product will not lose its dimensional stability, appearance, or permanent struc tural strength due to leaks which may occur in the roofing material, providing repairs to the roofing mem brane are made within a reasonable length of time. S. APPEARANCE AND MAINTENANCE -- The roof deck presents a smooth, attractive, light-reflective ceiling area which requires no maintenance. It may be painted if desired. s. thermal value -- The insulation value afforded by Gypsteel Plank is sufficiently high to meet the require ments of most industrial and commercial buildings in cluding factory areas, warehouses, and loading sheds. By comparison, the "U" value, including a built-up roof covering, of Gypsteel Plank is .52; steel decks--.94; 2" concrete plank -- .58; and 6" poured concrete --.65. y. fireproof--Gypsteel Plank is non-combustible. Be cause of the unusual properties of gypsum when subjected to heat. Gypsteel Plank affords greater fire protection to a building and its contents than any comparable system. Wood will burn when exposed to heat of 300 F., steel will begin to soften at 900 F., 1" of gypsum will con tain a fire of 1700 F. for one hour. This phenomenon allows gypsum to act as a fire insulator for areas to be protected. In case of fire, Gypsteel Plank will protect a building from fuel contribution from roofing materials a long as the structural support remains intact. USHO 002886 Inn technical THICKNESS 2" WIDTH 15" LENGTH 10' WEIGHT PER SQ* FT. 12# INSULATION COEFFICIENTS U-Factor (Air to Air) including roofing cover ing, V4" Gypsum Backer Board and Va" Acous tical Tile on bar joist or suspended ceiling. U-Factor (Air to Air) including a built-up roof covering. Thermal conductivity -- Btu per sq. ft. per hour per degree F. difference in tem perature. No Insulation .16 V4" Insulation .13 1" Insulation 12 No Insulation .52 Vi" Insulation .28 1" 1 Insulation .19 SPAN 4' 5' 6' T UNIFORM LOAD CARRYING CAPACITY CHART CARRYING CAPACITY 230 lbs. per sq. ft. 146 lbs. per sq. ft. 105 lbs. per sq. ft. 75 lbs. per sq. ft. SAFETY FACTOR 4 4 4 4 8 DESCRIPTION OF NAIL i va" square cut nail 11%" galvanized roofing nail NAIL HOLDING CHART HOLDING POWER OF DRY GYPSUMDIRECT PULL ON NAIL Penetration Va less than nail's length. 175.1 pounds 69.4 pounds 1 | I I | | j Carefully designed tongue provides for easy meshing, yet tight fitting joint, transmitting load from one plank to the adjacent one without causing separation of the plank. UPLIFT RESISTANCE: Standard clips have a holding power of 229 lbs. each. Based on an average of 2l/z clips per plank, this means a resistance to uplift of 46 lbs. per square foot which with the 12# deadload of the deck is more than ample to meet building code requirements. CANTILEVERING: Gypsum Plank may be cantilevered in the lengthwise direction up to 30 inches providing each plank is at tached to the exterior wall, that every other row of plank is started with a full plank and alternate rows are started with not less than a 4 ft. section. Gypsum Plank may be cantilevered up to 6 inches in a crosswise direction. FEDERAL SPECIFICATIONS: Gypsteel Plank meets Federal Specification SS-S-439, Type I, including the limitation on the deflection of 1/120 of the span with a 75# per sq. ft. live load over a clear span of 6' - 8". The plank will also pass the over load test requirements of this Federal Specification. USHO 002887 For school and institutional type buildings FLAT ROOF C*NTlLtVLRLD 5 TILL CONSTRUCTION Cypsteel Plank is widely used in the construction of schools and institutional buildings because of the su perior fire ratings and protection afforded by the product. The design, (as illustrated), is very adaptable for schools because it lends itself to the construction of a suspended ceiling to which a finished ceiling material may be applied. Consult technical data on page 3 for insulation co efficients requirements. Local' Building Codes should be consulted. Drawings are for purpose of illustration only and are not warranted by Bestwall Gypsum Company. V/O O O N AW-tR | 6*' | MAX. IF UNSUPPORTED \ iteel Ancle Tf y///1' Supporting Beam y/Z'J HI EAVE DETAIL TO NAILER SUPPORTING BEAM USHO 002888 SUPPORTING BEAM I F WALL SIDE OF FIRST ROW OF PLANK IS NOT SUPPORTED, CUT, SO END JOINTS ARE OVER BEARINGS. PARAPET WALL DETAIL flat roofs for industrial and commercial type buildings Gypsteel Plank has been designed to present a smooth, pleasant, light reflective surface. This finished appearance, coupled with a contemporary steel design a> illustrated, will create a modern appearance for any waiehouse, factory or manufacturing area. Gypsteel Plank affords protection against the rapid spread of fire in factory areas wheie the -iructurul ~teel is left exposed. The Plank, insulating the rmif covering materials from interior fire for a considerable period of time, prevents these materials from becoming contribu tory fuel. FLAT ROOF CANTlttVlftLD STttL CJUSTRUCTlOW NO CUE NG OCSlGWEO to* TOTAL LIVE AND DEAD LOAD 01 48 0*HR 544f T bAYS -ZO 0 * 2 OF i T(.(,, IUMS fta $Q I ' 01 R05F 0 C* BJfl x 10* l) i fcjenoii COL n 1 Local 8uilding Codes should be consulted. Drawings are for purpose of illustration only and are not warranted by Bestwall Gypsum Company. gypsteel pus*. i > no o<z . M.M4 Provide supporting frame for Rut. skylights AMD VENTILATORS. ALSO, FOR All OTHER OPENINGS, UHLLSS THEY COME VJlTWtH GYPSTEEL PLAMR FRAME. TYPICAL ME7HO0 Of FASTENING GYPSTEEL PLANK TO SUPPORTS. USHO 0 0 2 8 8 9 f. CURB DETAILS FOR OPENINGS (V-IONITORS SIMILAR.) HEAVY DUTY CLIPS ARE AVAllUU FOR PITCHED ROOTS; ALSO SPECIAL SIZES FOR MOST OfLM WEE JOIST?. USE 4dVI/i GALVANIZED SMOOTH SWAHX "WIRE HAILS FOR FASTENING CUPS TO GYPSTEEL FLANK. FASTENING DETAIL SAWTOOTH roof detail (.MONITORS SIMILAR.) pitched roofs for church and traditional type buildings Gypsteel Plank is a material similar to wood planking in handling, erection and nailability; however, it provides the added advantage of incombusti bility. A study of the fire insurance rates of any proposed structure will show that Gypsteel Plank supported on steel framework could provide considerable saving on fire insurance premiums. The illustrated designs have been used for churches, libraries, and other buildings where an incom bustible rating is desired. PITCHED ROOF TRUSS AND PURLIN SDNS t r oCTION 6AY5 - 20-0' H SO-O' OlSiCNlD FOR A. TOTAL UYl KN& LOAD OS S5 PLR SQH, HOS Wlllft I TRUSS Local Building Codes should be, consulted. Drawings are for purpose of illustration only and are not warranted by Bestwal! Gypsum Company. SvPPORTiMC, STLLL-- tr PITCH IS S IX OXMOU BOLT PLANK EVt*r lO-O' UP TMt st-ort, use yicAtRIAOE BOLTS UP TO 10:12., AND &'F PITCH IS 6RCATLR. recommendations and construction details Dm .sa, job storage St protection: Gypsteel Plank -hould l>e shipped, stored, hoisted and handled on edge with tongue edge up. never flat until laid in plate on the deck. The Plank should he protected from the ground by being placed on three -1- x 4`- equally spaced under the Plank. Gypsteel should then be covered by a tarpaulin or a polyethylene sheet to protect it from rain or snow. MOISTING: Plank should he placed on edge and hoi-ted to the roof with care to prevent damage of the tongued edge. cutting OF PLANK: Gyp-teel Plank 'houltl lie cut to (it hips, ridges, valleys and monitors in workman-like manner. This can he accomplished h> the use ofa wide set hack saw to cut the steel binding, the gypsum core scored and 'trapped and finally the wire mat rut. Where power equipment is available, the Plank mav he cut with an electric hand saw. ( ^' When using an electric hand -aw the tollou- ing resinoid blades are recommended lu their manufacturers: Bag State Abrasive Company \o. BGR Carborundum Company No. TC 1107-T-15.4 Eveready Briksaw Co.. Inc. No. .ii.'i Norton Company .No. ;>7C211-01IBN Skilsaw. Inc. Abra-iie Di-c- Table saws can be used with a center resinoid blade manufactured by the Carborundum Company -- No. RC-16-Q-B7N. V J painting: Where painting of the underside of the deck is specified, the Plank should he dry before proceeding. In the event the Plank becomes wet due to rain or other weather conditions before the roof covering is applied or if the interior construction contributes moisture through condensation on the underside, the roof deck should be completely dried from the underside, by heat and ventilation if necessary, before proceeding with painting. The steel binding should he primed with a product designed for use oier new galvanizing. For be-l results the entire underside of the deck should be primed before painting. Painting specifications of re liable paint manufacturers may be used. roof covering: Any type of standard roofing may be applied over Gypsteel Plank. Asphalt and asbestos shingles, and other lightweight roofings may he nailed directly to Gypsteel Plank using I-G. 10 gauge LARGE HEAD. GALVANIZED ROOFING NAILS. Slate roofing may also he nailed directly to Gypsteel Plank using square cut galvanized or hard copper nails. Nails should penetrate IV2" into Plank. For built-up roof'. nail the first two ply# directly to the deck. This layer then acts as a dry or slip sheet to which additional plys may be mopped. Consult the specifications of reputable roofing manufacturers for detailed requirements. REPAIRS: Repairs may be made by simply knocking out the damaged core (leaving the reinforcing mat in placet, then placing a plywood form on the underside and pouring a new core with Bestwall Metro Mix gyp sum concrete. If roof covering is in place. Plank may he repaired by plastering with Bestwall Wood Fiber Plaster from the underside. excessive humidity or heat: Under certain conditions of excessive heat and humidity, special en gineering and design treatment may he required. Submit details to our nearest sales office for recommendations. USHO 002891 gypsteel plank a modern product for modern buildings SPECIFICATIONS scope: Unless otherwise designated in plans, all root' areas shall he covered with BESTWALL GYPSTEEL PLANK and all cants and saddles shall be constructed as shown or specified herein. materials: All roof deck areas shall be covered bv GYPSTEEL PLANK 2" x 15" x 10' as manufactured bv the BESTWALL GYPSUM COMPANY. Clips to secure Gypsteel Plank to the structural members .'hall be furnished by the Plank manufacturer. (Unless otherwise determined, the clips should be ordered at the rate of 2 (A per individual plank. | Nails. 2 per clip, shall be -Id galvanized slater nails or 1(4" smooth shank, gal vanized roofers nails. All cants and saddles shall be constructed of BESTWALL METRO MIX gypsum concrete as manufactured by the BESTWALL GYPSUM COMPANY. erection: Start laying Gypsteel Plank at a corner of each independent area with the long dimension at right angles to the supports. laying the tongued side toward the exterior wall. Be certain the trademark face is up. Start with a full Plank in the first row. a half or cut Plank in the second row, a full Plank for the third row. and on for each succeeding row. Side and end joints shall be meshed as tightly as possible to form a smooth continuous surface. End joints must be staggered whether they come over the ~upports or not. To accomplish this, the Planks which are left after cutting to fill out one row may be used to start another row, since it is not necessary to have a Plank receive support from two purlins to start a row. In staggering end joints, leave a minimum of thirty inches between them. Cut Plank to fit all hips, ridges and valleys as required by plans. Fill any voids with Best wall Metro Mix gypsum concrete to present a finished area. Attach the Plank to the top cord of steel purlin or joist at every point of support with galvanized steel clips fur nished by the manufacturer. Where possible, clips should be placed on alternate sides of steel purlins on succeed ing rows. When Plank is laid over wood roof joints, the same erection details shall be followed except that the Plank shall be nailed with two I6d spikes at every point of support. In lieu of nailing plank to joists they may be wire tied by nailing into the edge of the Plank and using 1-f gauge galvanized or Monel wire tied to nail in side of joi't's. Special nailing or a wire tie detail may be used in applying Gypsteel Plank to concrete joists. On all Gypsteel Plank roofs with more than 4" pitch per foot, the thrust shall be taken up at the eaves by a slop angle or other member of appropriate size and strength. If pitch is more than 5" but less than 10" to the foot, bolt Plank every 10' up the slope using y>" carriage bolts. When pitch exceeds 10" to the foot use :M" carriage bolts in similar manner. On all sloping roofs, proper type clip for structural support made of heavy gauge metal shall be used. See details. Cants and saddles shall be installed as indicated on plans using Bestwall Metro Mix gypsum concrete at a water ratio of 7 to 8 gallons per 80 lb. bag. On all overhanging deck areas a wood nailer shall be attached to the edge of the Plank flush with the deck 'urface to provide for attaching gravel stop and roof covering. &ESTWALL USHO 002892