Document oMDJ85mEQrJozzNEjnn1LVZrX
THORPE PRODUCTS COMPANY
DIV ISION OF
JT
TH ORPE
COMPANY
DISTRIBUTORS
P.O. BOX 33399
July 28, 1972
OF
NDUSTRIAL
NSU LAT I O N
6 4 4 - 2 3 91
HOUSTON, TEXAS 77033
Mr. Pat Griffin MONSANTO COMPANY P. 0. Box 711 Alvin, Texas 77511
Subject:
OSHA Asbestos Dust Standard Effective July 7th, 1972
Thorpe has had many requests for information regarding compliance with these new standards and in regard to asbestos containing insulating materials which we are furnishing to industry.
This letter is to make available to you our latest information and to offer.any assistance possible where and when needed to assist you in compliance.
Attached is a copy of a news release from the U. S. Department of Labor which summarizes this new standard.
Also attached is a listing by type of material stocked or fabricated byThorpe. Those having dry. asbestos as a component are marked with an asterisk. Those most commonly used by industry are those included under Class I - Calcium Silicate and High Temperature Insulation.
We have tak;eq ^fgpc: pp pj.iTrn'nate asbestos from all products wh ichwe "stock and fabricate. 3v Januarv^ls t, 1AZ3,_we._expecxI^IKiye^a^new pipe ""covering produced by Johns'-JdLanvi1 ie jwhich. wil_l_have the same or_better
"properties as Thermobesros. but..will contain no Asbestos^oF'free Silica.
^
Until we have this new product we offer the following suggestions for compliance:
Eliminate all field fabrication of Asbestos products. When frequent removal of insulation is required, Thorpe can furnish prefabricated Thermobestos covers or completely incapsulated removable metal covers.
t continued ......
*
*
c 000283
LAM022193
OSHA Asbestos Dust Standard Effective July 7th, 1972 Page 2 of 2 pages
Elbows can be insulated by the use of: A. Prefabricated or factory molded covers B. Aluminum covers' filled with asbestos free insulating
^ cement C. Zeston PVC covers with 1000 Fiberglas filler D. Zeston PVC covers with asbestos free insulating cement
II. Where cutting is required, the use of a respirator such as Safe line Products No. 5441 Mask with No. 5905 Filter or any respirator carrying the U. S. Bureau of Mines Approval No. 21B-81.
III. Use substitute materials containing no asbestos as follows: A. Microlok Fiberglass Pipe Covering to 500 F B. Mineral Fiber Pipe Covering to 1200 F C. Ceramic Fiber to 2300 F
Thorpe is currently monitoring its operation with the use of Micronair Personnel Air Samplers Catalog No. 3900-10 as produced by the Bendix Corporation and carrying OSHA Approval No. 1A-102. Dust analysis can be made by Shilstone Testing Laboratories, Houston, Texas.
We have made extensive provisions for dust collection in our warehouses and fabrication facilities. Our cutting equipment have the most effective collection attachments that we can obtain. You- are welcome to visit our Houston facility at any time. Arrangements can be made through the writer.
CAUTION: When considering Asbestos Free products, be sure also that they contain no Free Silica. Manufacturers will generally offer this information in writing.
The enclosed information is fragmentary. Please call us for additional information or assistance. Copies are available for your Safety Department or person responsible for OSHA compliance.
We appreciate your business and hope that the enclosed information will be beneficial to you and will help us earn your continued trust and confidence in our services.
THORPE PRODUCTS COMPANY
M. P. Proctor
MPP:pb
Enclosure
c 000284
U/VI022194
FORTY-EIGHT INSULATIONS INC.
AURORA. ILLINOIS
3802 January 1972
FORTY-B EIGHT SUPER "48" CEMENT
SUPER "48" CEMENT is an all purpose, high temperature insulating and bonding cement for the full range of temperatures to 1800F. It is manufactured frem a controlled blend of resilient, 1600F refractory fibers and special high temperature binders. SUPER "48" CEMENT contains no asbestos, is actively rust-inhibitive and will not cause or accelerate corrosion when properly applied to iron or steel surfaces. SUPER "48" has exceptional bonding adhesion, trowels smooth, has minimum shrinkage, and maximum thermal efficiency. Not hydraulic-setting, it is reclaimable at temperatures up to 1200F. Simply re-mix with clean water and use again.
SUPER "48" is recommended for use on irregular surfaces, general insulating and maintenance work, ducts, breeching, turbines, valves, fittings, or as a leveling material over other insulations. Application subjected to outside weathering must be protected.
-- ki1
n.n.,,.
ufttuu. H'WHTOi'
"ctwampum,u muwj.T-.wmi
THERMAL CONDUCTIVITY
MEAN TEMPERATURE 200F 400F 600F 800F
K-FACTOR .585 .64 .73 .85
Hot Face 200 F 350F 550F
RECOMMENDED THICKNESSES:
Thickness
Hot Face
1" 750F
IV 950F 2" 1200F
Thickness 2V 3" 4"
SERVICE TEMPERATURE: Up to 1800F.
DRY COVERAGE: 45-50 sq. ft. 1" thick per 100 lbs.
INSTALLED DENSITY: Approx. 28 lbs. per cubic foot.
VOLUMETRIC SHRINKAGE: (Wet to dry) Approx. 15%.
CORROSION TO STEEL: Non-corrosive.
LEACHABLE CHLORIDES: Less than 25 ppm.
SPECIFICATIONS: Federal: A.S.T.M.
HH-C-168 SS-C-160, Type III, Grade U MIL-C-2861D; MIL-I-24244(SHIPS) C-195
PACKAGING: Strong, multiwall bags of 50 pounds. it
Values shown are subject to our normal manufacturing and testing methods and tolerances.
c 000285
LAM022195
THORPE PRODUCTS COMPANY
HOUSTON
DALLAS
BEAUMONT
<1 * THE FOLLOWING IS A LISTING BY TYPE OF INSULATING MATERIALS STOCKED OR
FABRICATED BY THORPE
I. CALCIUM SILICATE AND HIGH TEMPERATURE INSULATIONS
A. Thermobestos - Pipe Covering and Block *
B. Metal-On Pipe Insulation
*
C. Superex' Block
II. FIBERGLASS INSULATIONS A. Micro-Lok Pipe Insulation (snap-on) B. Microlite Blanket C. Duct Liner - Lina Coustic
III.
MINERAL WOOL A. Spinglas 1000 Blanket B. #10 Blanket C. Griptex Block D. MF Pipe Covering E. Minibond - Stress Relieving Blanket F. Cerafelt G. ' C-erafiber
IV. FOAM INSULATIONS A. Urethane - Pipe Covering and Block B. T-Foara - Two Component Pour Urethane C. Styrofoam D. Ceramic Foam
V. UNDERGROUND INSULATION A. Witcolite B. Trisulite
VI. CELLULAR GLASS INSULATION A. Foamglas - Pipe Covering and Block
VII.
INSULATION ACCESSORIES
A. Cements
1. 48 Insulation, Inc. a. Quik Set (One Coat)
b. Super 48 2. Johns Manville
a* 352 Cement
1000 Temp. 1800 Temp.
*
Continued
7/1/72 - Page 1 of 3
C 000286 LAM022196
.\ \
FORTY-EIGHT INSULATIONS INC.
AURORA. ILLINOIS
"
FORTY^ EIGHT QUIK-SET CEMENT
3804 January 1972
QU1K-SET CEMENT is a one coat, hydraulic-setting, high temperature bonding cement that insulates and trowels or palms to a smooth, hard, white finish. QUIK-SET CEMENT is a dry mixture of fcigh temperature fibers and a combination of adhesive bonding and hydraulic-setting binders and contains no asbestos. QUIK-SET CEMENT combines the high temperature resistance and excellent insulating qualities of uniformly nodulated mineral fibers with the high strength, low shrinkage and smooth finish of hydraulic-setting cement. After mixing with water, it will remain workable for up to two hours. QUIK-SET CEMENT takes a green set in two to four hours and will then withstand effects of rain or moisture without softening. Initial troweling produces a satisfactorily White surface. Subsequent steel troweling within 30 minutes after application will give a superior surface with a bright, attractive glaze.
QUIK-SET CEMENT is designed for use on valves, fittings and heated equipment, or as
an insulating finish over other insulations. Outside applications must be protected
with an appropriate weatherproofing.
wn
iliumjry...'Urnunwsun.jwm..jii
THERMAL CONDUCTIVITY
MEAN TEMPERATURE 200 F 400 F 600 F 800 F
K-FACT0R .60 .70 .80 .96
SERVICE TEMPERATURE: Up to 1200F.
DENSITY: 40 lbs. per cubic foot.
COVERAGE: 30 sq. ft., 1" thick per 100 lbs. ADHESION: Good. SHRINKAGE: Negligible.
INITIAL SET: Approximately 2 hrs. after application.
WEATHER RESISTANCE: Will not soften after initial set.
LEACHABLE CHLORIDES: Less than 25 ppm.
SPECIFICATIONS:
Federal: A.S.T.M.:
MIL-C-2908A, Type II MIL-I-24244(SHIPS) SS-C-160, Type III Crade F C-449
PACKAGING: Packaged in moistureproof raultiwall bags of 50 lbs. for longer warehouse storage life and additional on-site quality protection.
Values shown are subject to our normal manufacturing and testing methods and tolerances. it
C 000287
LAM022197