Air System Equipment
Curtis Manufacturing Company
Refrigeration Division
1959 Kienlen Ave. St Louis 20, Missouri, U. S. A.
New Yobs Office
Chicago Office
SO Veset St.
0 S. Clinton St.
Established 1854
Products: Full line of Packaged Air Conditioners from 3 through 50 ton, Condensing Units from through 100 hp with Cooling Towers, Air Handling Units to match. Packaged Water Chillers through 100 hp. Waterless Air Cooled Packaged Con densing Units, 3 through 7}4 hp, Residential and Commercial.
COMMERCIAL REFRIGERATION
Air cooled condensing units from Y to 3 hp, inclusive, and water cooled units from ^ to 50 hp, inclusive. All models charged with "Freon 12" refrigerant. 2 hp and larger available with "F-22" refrigerant. Mechanical advantages in clude Timken Bearings, positive pressure lubrication.
PACKAGED LIQUID CHILLER 7^ through 100 ton. For air conditioning or industrial processing and other types of liquid application. "F-12" or "F-22" re frigerant. Uses same piping as heating system.
PACKAGED AIR CONDITIONERS 25 through 50 ton. Line assembled at fac tory. Eliminates expensive field labor. Tested before delivery to assure balanced system. Integral evaporative condensor optional.
PACKAGED AIR CONDITIONERS in 3 through 20 ton.
WATERLESS AIR COOLED PACKAGED CONDENSING UNIT for residen tial and commercial application, 3-5-7^ ton.
182
Air System Equipment SgKf8
Dole Refrigerating Company
5918 N. Pulaski Road, Chicago 30, 111. 103 Park Ave., New York 17, N. Y.
In Canada: Dole Refrigerating Products Limited, 44 Elgin St., Brantford, Ont.
Manufacturers of Air Conditioning and Refrigeration Equipment
ICE-CEL Interior X- Unit
ICE-CEL ACCUMULATOR UNITS
LATENT HEAT ICE STORAGE SYSTEMS FOR AIR CONDITIONING
APPLICATION: DOLE ICE-CELS are used wherever the air-conditioning load is high for a relatively short period of time, such as in churches, mortuaries, audito riums, lodge halls, cafeterias, offices, theaters, motels, retail stores.
OPERATION
The ICE-CEL consists of an assembly of DOLE Vacuum Plates submerged in a tank of water. A condensing unit is con nected to and refrigerates the plates, causing ice to build up on their surface. A control is available to stop the con densing unit when the ice has reached any desired thickness. When cooling is to begin, chilled water from the ICE-CEL is pumped through a water coil in the air stream. In passing over this coil, the air gives up its heat to the water which is then returned to the ICE-CEL for re chilling and re-circulation.
Since the compressor capacity can b< spread over the whole day, if necessary rather than just for the duration of th< actual cooling period, a much smalle condensing unit, together with a cor respondingly smaller cooling tower o: evaporative condenser, can be used. This eliminates the need for water econ omizers. Also a compressor used for othe: purposes and not needed full time cai have its idle periods devoted to building up ice on the ICE-CEL to be used whih the compressor is doing its regular job As a result, operating costs are kept at i minimum, especially in areas where de mand power rates are in effect. Th(
existing power service to the building is usually adequate.
HOLDOVER CAPACITIES AND BUILDUP TIME FOR STANDARD ICE-CEL UNITS
STANDARD LHS-12 LHS-21 LHS-31 LHS-51
ICE-CEL
or
or
or
UNITS LHS 12x LHS21x LHS31x LHS 51x
Hold-over 1 capacity |45 18 T.H.
at given [40 17 T.H. inlet water.340 13 T.H.
temp. I
32 T.H.
31 T.H. 24 T.H.
48 T.H. 47 T.H.
36 T.H.
81 T.H. 77 T.H.
60 T.H.
| U*8
Comp. HP
St H to H
w GO w GO w GO U
I HP 1 HP
14 HP 2 HP 3 HP
5 HP
74 HP 10 HP
15 HP 20 HP
26 Tfl 21 17 16 12 25 19 13 8 .20 16" 27 20 11 3" 15 11 20 16 29 21
11 4" 14 10" 20 16" 10 1 11 4 15 11
10 0" 13 7" 10 2
9 2"
NOTE: Add 10 percent if starting water over 50 deg.
Add 5 percent if starting water between 40 deg-50 deg. S.T. indicates approximate suction temperature
at end of ice buildup. Condensing units smaller or larger than shown not recommended.
ENGINEERING SERVICE
Complete Engineering Catalog BAE and further technical information available on request. A DOLE application en gineer is located near you to give you prompt service. Write, wire, or phone.