Document oDb3pxB4BqOmOMrBaZwQpG297
86
CHAPTER 4
1958 Guide
formed between the float and inside wall of the tube. At any particular^
rate of flow, the float assumes a definite position in the tube, its location'^
being indicated by means of a calibrated scale on the tube.
ff
va
The position of the float is established by a balance between the fluids pressure forces across the annulus and the weight of the float itself. The'a
buoyant force which must support the float, vt(pt -- p), is balanced by thej
pressure difference acting on the cross-section area of the float, AsAp}i where pt, At, Vi, are, respectively, the float density, float cross-section area^l and float volume. Accordingly, the difference in head across the ahnulus||
is-given by-
-la
f,t, = A--p = --ft(p-i ------p-)
p Alp
, l
if
CAPACITY SCALE
`OR REFERENCE SCALE
TAPERED TRANSPARENT METERING TUBE
II
Fig. 18. Schematic Diagram of Variable Area Flow Meter
The volume flow follows from equation (53) as
Q = KAiV2yt>,(p, -- p)/pA,
and the mass flow as
: pQ = KA,\Z2gv,(pi - p)-p/A,
=(68)1
The flow for any selected fluid is, accordingly, very nearly proportionals to the area, so that a convenient calibration of the tube may be obtained! The behavior of the flow coefficient, K, has been investigated6 and the ac|
tion of the flow meter as just outlined, experimentally confirmed. Tliej flow coefficient variation for any float must be known in order to use th|
meter for different fluids. Some developments have been carried on i&' the design of the float to reduce the variation of the flow coefficient with'
Reynolds number, and also with regard to float materials, to reduce tb;
dependence of mass flow calibration on fluid density.
1
This type of flow meter is usually furnished in standard sizes calibrate^
Fluid Flow
87
for specific fluids by the manufacturer. The compactness, reliability, and ease , of installation are particularly advantageous when many measure ments of essentially the same type are to be made.
LETTER SYMBOLS USED IN CHAPTER 4
p = ratio, throat or. orifice diameter to pipe diameter. n * absolute viscosity, pounds per foot second.
n/p = kinematic viscosity, square feet per second.
p -- density of flowing fluid, pounds per cubic foot. pm = proper mean density.
pw = density of water at 60 F (62.37 lb per cubic foot). pt = density of float in variable area meters. <t> = expansion factor for nozzles.
0 = velocity of sound, feet per second.
A =* cross-sectional area of flow, square feet.
C = correction factor (coefficient of discharge) for flow through orifice, nozzle
or Venturi.
\
cP = specific heat of gas at constant pressure.
Cv = specific heat of gas at constant volume. D ~ diameter of fluid stream, feet. d = internal diameter of pipe, feet.
-
dH -- hydraulic diameter, feet,
e = absolute roughness of pipe surface, feet.
Fe -- correction factor for differential head in compressible flow. / = dimensionless friction coefficient.
g -- gravitational acceleration, feet per (second) (second).
gc " gravitational conversion factor = 32.174 (pounds mass per pound force) X feet per (second) (second).
h enthalpy, Btu per pound of fluid.
hi = loss of head, feet of fluid. hi = total head, feet of fluid.
J ~ mechanical equivalent of heat = 778 foot pounds per Btu.
K = flow coefficient (correction factor), including velocity of approach correc
tion factor, for flow through orifice, nozzle or Venturi. k = ratio of specific heat at constant pressure to specific heat at constant vol
ume.
L ~ perpendicular distance from axis of pipe, feet.
1 = length of pipe, feet. M = Mach number. -VRe = Reynolds number.
P = pressure, pounds per square foot. p = stagnation pressure.
pc = critical pressure.
Q = discharge rate, cubic feet per second.
q = heat transferred to the fluid per pound of fluid flowing. R = gas constant,
r = radius of pipe in feet.
* -- entropy of fluid in Btu per (pound) (Fahrenheit degree). a -- temperature, Fahrenheit degrees, absolute. u *= internal energy, Btu per pound of fluid. V ** velocity, feet per second.
Vc = critical velocity, feet per second.
v = specific volume, cubic feet per pound. w ^ mechanical work, foot pounds per pound of fluid flowing.
y ~ mass flow of gas, pounds per second.
` -- expansion factor--correcting for expansion of gas under reduced down stream pressure.
2 ~ elevation above some arbitrary datum, feet.
REFERENCES
1044^fl7iticSo^'ac?ors *or Pipe Flow, by Lewis F. Moody (ASME Transactions, 66,
frt_ a*
Discussion, idem. 66, 1944, 678-684); also, An Approximate Formula
r riPe friction Factors {Mechanical Engineering, 69,1947,1005-1006).