Document oDb3pxB4BqOmOMrBaZwQpG297

86 CHAPTER 4 1958 Guide formed between the float and inside wall of the tube. At any particular^ rate of flow, the float assumes a definite position in the tube, its location'^ being indicated by means of a calibrated scale on the tube. ff va The position of the float is established by a balance between the fluids pressure forces across the annulus and the weight of the float itself. The'a buoyant force which must support the float, vt(pt -- p), is balanced by thej pressure difference acting on the cross-section area of the float, AsAp}i where pt, At, Vi, are, respectively, the float density, float cross-section area^l and float volume. Accordingly, the difference in head across the ahnulus|| is-given by- -la f,t, = A--p = --ft(p-i ------p-) p Alp , l if CAPACITY SCALE `OR REFERENCE SCALE TAPERED TRANSPARENT METERING TUBE II Fig. 18. Schematic Diagram of Variable Area Flow Meter The volume flow follows from equation (53) as Q = KAiV2yt>,(p, -- p)/pA, and the mass flow as : pQ = KA,\Z2gv,(pi - p)-p/A, =(68)1 The flow for any selected fluid is, accordingly, very nearly proportionals to the area, so that a convenient calibration of the tube may be obtained! The behavior of the flow coefficient, K, has been investigated6 and the ac| tion of the flow meter as just outlined, experimentally confirmed. Tliej flow coefficient variation for any float must be known in order to use th| meter for different fluids. Some developments have been carried on i&' the design of the float to reduce the variation of the flow coefficient with' Reynolds number, and also with regard to float materials, to reduce tb; dependence of mass flow calibration on fluid density. 1 This type of flow meter is usually furnished in standard sizes calibrate^ Fluid Flow 87 for specific fluids by the manufacturer. The compactness, reliability, and ease , of installation are particularly advantageous when many measure ments of essentially the same type are to be made. LETTER SYMBOLS USED IN CHAPTER 4 p = ratio, throat or. orifice diameter to pipe diameter. n * absolute viscosity, pounds per foot second. n/p = kinematic viscosity, square feet per second. p -- density of flowing fluid, pounds per cubic foot. pm = proper mean density. pw = density of water at 60 F (62.37 lb per cubic foot). pt = density of float in variable area meters. <t> = expansion factor for nozzles. 0 = velocity of sound, feet per second. A =* cross-sectional area of flow, square feet. C = correction factor (coefficient of discharge) for flow through orifice, nozzle or Venturi. \ cP = specific heat of gas at constant pressure. Cv = specific heat of gas at constant volume. D ~ diameter of fluid stream, feet. d = internal diameter of pipe, feet. - dH -- hydraulic diameter, feet, e = absolute roughness of pipe surface, feet. Fe -- correction factor for differential head in compressible flow. / = dimensionless friction coefficient. g -- gravitational acceleration, feet per (second) (second). gc " gravitational conversion factor = 32.174 (pounds mass per pound force) X feet per (second) (second). h enthalpy, Btu per pound of fluid. hi = loss of head, feet of fluid. hi = total head, feet of fluid. J ~ mechanical equivalent of heat = 778 foot pounds per Btu. K = flow coefficient (correction factor), including velocity of approach correc tion factor, for flow through orifice, nozzle or Venturi. k = ratio of specific heat at constant pressure to specific heat at constant vol ume. L ~ perpendicular distance from axis of pipe, feet. 1 = length of pipe, feet. M = Mach number. -VRe = Reynolds number. P = pressure, pounds per square foot. p = stagnation pressure. pc = critical pressure. Q = discharge rate, cubic feet per second. q = heat transferred to the fluid per pound of fluid flowing. R = gas constant, r = radius of pipe in feet. * -- entropy of fluid in Btu per (pound) (Fahrenheit degree). a -- temperature, Fahrenheit degrees, absolute. u *= internal energy, Btu per pound of fluid. V ** velocity, feet per second. Vc = critical velocity, feet per second. v = specific volume, cubic feet per pound. w ^ mechanical work, foot pounds per pound of fluid flowing. y ~ mass flow of gas, pounds per second. ` -- expansion factor--correcting for expansion of gas under reduced down stream pressure. 2 ~ elevation above some arbitrary datum, feet. REFERENCES 1044^fl7iticSo^'ac?ors *or Pipe Flow, by Lewis F. Moody (ASME Transactions, 66, frt_ a* Discussion, idem. 66, 1944, 678-684); also, An Approximate Formula r riPe friction Factors {Mechanical Engineering, 69,1947,1005-1006).