Document oDEXpvrjwZzgXoDjZQaGYEn9w
400
CHAPTER 19
1949 Guide
where
H =. height of chimney, feet. Bo = existing barometric pressure, inches of murcury. Wo = density of air at 0 F and 1 atmosphere pressure, pounds per cubic foot. W' = density of flue gas at 0 F and 1 atmosphere pressure, pounds per cubic foot. To = temperature of air surrounding the chimney, Fahrenheit degrees absolute. To = average or effective temperature of the gases in the chimney,Fahrenheit
degrees absolute.
The quantity Dt, yielded by, the formula, is the pressure difference be
tween. the gas inside and air outside of the chimney, in inches of water,
when no flow occurs in the chimney. The quantity is variously known as
the theoretical draft, the static draft or the computed draft. It is very,
useful in predicting and analyzing chimney performance, but it is seldom
if ever attained in an actual chimney because of the friction incident to
gas flow, wind effects, etc.
-
AVAILABLE DRAFT
. The available draft, Z>, for large chimneys and.stacks has been.estimated, with apparent satisfaction in the past by means of formulas which in effect deduct an estimated friction loss from a theoretical draft determuied as; in Equation 1. The friction loss can be estimated by means of one of the formulas available for ducts, such as the Fanning equation. This pro cedure results in formulas for the available draft as follows: .
For a cylindrical stack:
Do =
2.96 HB,
(Wo _ V^O
To)
_ 0J00126W'TofL b*BoWo
(2)
and for a rectangular stack:
Do
--
2.96 HBo |
Wo ^ To~
HV\ To)
^ 0.000338W*TofL(x Hy>BoWo
+
y)
where
Do = available draft, inches water gage.
`
H = height of chimney above grate, feet.
Bo = existing barometric pressure, inches of mercury. .
= density of air at OF, 1 atmosphere pressure.
,
Wo "density of flue gas at OF, 1 atmosphere pressure.
To -- temperature of atmosphere, Fahrenheit degrees absolute.
To = temperature of flue gas, Fahrenheit degrees absolute.
W = flue gas flow rate, pounds per second.
/= coefficient of friction.
L = length of friction duct (approximately equal to H), feet. minimum diameter of round chimney, feet.
' .j
x and y -- length and width of cross-section of rectangular chimney, feet.' .
The following notes facilitate the;use of Equations 2 and 3.
1 The barometric -pressure, represented by Bo, is the actual pressure at the site of the chimney and not the pressure reduced to sea level datum.
Chimneys and Draft Calculations
401
In general, the barometric pressure decreases approximately 0.1 in'. Hg per 100 ft increase-in elevation.
2. The unit weight of a cubic foot of chimney gases at 0 F and sea level barometric pressure is given by the equation:
W. = 0.131CO, + 0.0950, + 0.083AT,
(4)
In this equation CO,, O, and A7, represent the percentages of the parts by volume of the carbon dioxide, oxygen and nitrogen content, respectively, of the gas analysis. For ordinary operating conditions, the value of Wc may be assumed at 0.09.
The density effect on the chimney gases due to superheated water vapor resulting from moisture and hydrogen in the fuel, or due to any air infiltration in the chimney proper is disregarded. Though water vapor content is not disclosed by Orsat analy sis, its presence tends to reduce the actual weight per cubic foot of chimney gases.
3. The atmospheric temperature is the actual observed temperature of the. outside air at the time the analysis of the operating chimney is made. The mean atmospheric temperature in the temperate zone is approximately 62 F.
4. The chimney gas temperature decreases from the breeching connection to the top of the stack. ^ This drop in temperature depends upon the material and construction of the stack, its tightness or freedom from leaks, its area, its height, and the velocity of the gases through it. The same chimney will suffer different temperature losses depending upon the capacity under which it is working and the variable atmospheric conditions. No general equation covering all these variables has been suggested, but from observations on chimneys varying in diameter from 3 to 16 ft and in height from 100 to 250 ft Equation 5 was deduced1:
where
Z.13T,Rff-I
..To = H\> -- 3
(5)
T-% -- temperature at the center of the connection from the breeching, Fahrenheit degrees absolute.
Hb = the height of the stack above center line connection to breeching, feet.
5. The coefficient of friction between the chimney gases and a sooted surface has been taken by many workers in this field as a constant value of 0.016 for the condi tions involved.. .This value, of course, would be less for a new unlined steel stack than for a brick or brick-lined chimney, but in time the inside surface of all chimneys re gardless of the materials.of construction becomes covered with a layer of soot, and thus the coefficient of friction has been taken the same for all types.of chimneys and in general constant for all conditions of operation. For reasons of simplicity and convenience to the reader, this constant value of 0.016 has been employed in the de velopment of the"various special equations and charts shown in this chapter.
In important chimney design, especially when the construction or the materials are unusual, it is recommended that use be'made of the Reynolds number* iri deter mining the friction factor,/.
The following problem illustrates the use of Equation 2:
Example 1. Determine the available draft of a natural draft chimney 200 ft in
height and 10 ft in diameter operating under the following conditions: .atmospheric
temperature, 62 F; chimney gas temperature, 500 F; sea level atmospheric pressure, B0 = 29.92 in. Hg; atmospheric and chimney gas density, 0.0863 and 0.09, respectively; coefficient of friction, 0.016; length of friction duct, 200 ft. The chimney discharges 100 lb of gases per second;
Substituting.these values in Equation 2 and reducing:. .
.
0.0863 0.09\ Do = 2.96 X 200 X 29.92 X |
522 960/
0.00126 X 100* X 960 X 0.016 X 200 10s X 29.92 X 0.09
= 1.27-0.14= 1.13 in.
Fig. 1 shows the variation in the available draft of a typical 200 ft by 10 ft chimney operating under the general conditions noted in Example 1.