Document oDDz51nj8yxQx4Ev7ER7zvaw7

PLAINTIFF'S EXHIBIT * A CLEARING THE AIR .. * T* v-i' . <* V - - i' ' " sf. irw. -V % A- v;.:Af. , .... -H 4T- r,. -I f* -r- ~ ';*V t.. .v- - f- .r-.lfr* - . . ' . : i - $ ... * i, ' 4> . .. -4 . . 0. * f . *'; '- ' - ' *,*.- . .iv.. - -*..*.. --*a* a -^ * y* ' - * - c *.* ".`Ii.* .. * . r %,,: . -*. - f * ; . ' .- : ;- . . ,, * * m*'.' _ .r- 4L ' ' y ;J. y^^||ir|Roi!Mtiqni^5htro1 Division *-. v t*/^^aWheelqbrdfor-Frye Inc. 'W-> :: v '>.4! 1 . DMART 266 ~CONFIDENTIAL INA V. ASABnn L-6 ASNJ.EP 001097 i OPERATION AND SERVICE MANUAL for Air Pollution Control Unit TYPE OF UNIT: WHEELABRATOR-FRYE DUSTUBE DUST COLLECTOR SIZE NO. 1217, MODEL 171, SERIES 5S PROPRIETOR: ASARCO INCORPORATED 120 BROADWAY NEW YORK, N.Y. 10005 CONTRACT / SERIAL NO.: 2412 CUSTOMER ORDER NO.: 16H-0348 DATE OF ISSUE: MAY 1976 Designed and Manufactured by:- Air Pollution Controli Division Wheetabrator-Frye Inc. 600 Grant Street. Pittsburgh. Pennsylvania 15219 Tn/r Wheelabrator-Fiye Inc. is one of the world's foremost suppliers of standard and custommade pollution-control equipment, including "DUSTUBE" dust collectors for handling dry particulates; the "ULTRA-FILTRATION" process for removal of the most minute particulates suspended in gas or air; "ULTRA-JET" fabric filters with pulse-type bag cleaning: ULTRA-DYNE" units for removing liquid particulates; and Wheelabrator Lurgi Electrostatic Precipitators. UJhedabrotor-Frye environmentalSystems-- -- working to ro/ve environmentalproblems. Wheelabrator-Frye Inc. has built a complete systems capability to design, engineer, erect, operate, maintain, and finance large process pollution control facilities. It can draw on the experience of over 68 years in pollution control and 20,000 air pollution control systems throughout North America and 22 foreign countries. This organization is the result of a 1971 merger that brought together and concentrated the best elements of four operating companies. In 1972, a very important part of the team was added--the Rust Engineering Company, with a proven record of accomplish ment in the design, erection, and maintenance of many industrial processes including pollution control equipment, incinerators, and chimneys. Wheelabrator's new high-technology systems organization is further enhanced Iw working agreements with two other world leaders in specialized, proprietary pollu tion control equipment--Von Roll A. G. of Zurich, Switzerland, and Lurgi Apparate Technik GmbH of Frankfurt, West Germany. The agreement with Von Roll has made available new knowledge and technical appli cations in the design and operation of refuse incineration systems, including the re cycling of heat energy from refuse and the reclamation of materials from waste. Lurgi brings to this new combination an exclusive license to manufacture and market their electrostatic precipitators in North America, and a far-reaching agreement for the introduction of their proprietary water and waste water handling systems into the U. S. Wheelabrator-Frye has for a number of years accounted for 20-25% of the expanding U. S. fabric filter market, and 40% of the Canadian market. It is a multinational com pany with annual sales of over $218 million and its broad capabilities are demonstrated by the wide range of worldwide businesses and industries it serves, including steel mills, foundries, automotive plants, the' cement, asbestos, chemical, pulp and paper industries, municipal incinerators, and many other pollution-related installations. This success has been brought about by 'Wheelabrator's comprehensive high-technology systems approach that assesses the customer's total environmental problems, designs and engineers pollution control facilities, services the facilities, supplies replacement parts, and provides financing arrangements when desired. I CONTENTS CONTENTS PART XI. INTRODUCTION PART III. SYSTEM DESCRIPTION Equipment Description Bulletin APC-3 DUSTUBE Dust Collector PART IV. INSTALLATION AND OPERATION Erection Instructions for Pre-Engineered Dust Collector Installation Instructions for Strap Top Bags on Three Prong Tube Hook Installation Instructions for Nameplates Instructions for Inspection and Maintenance of DUSTUBE Dust Collector Shaker Type Instructions for Manometers Instructions for Cleaning or Rebagging Pollution Control Units Instructions for Applying Gasketing and Cements PART V. PARTS LISTS ' General Information Ordering Information Recommended Spare Parts List PART VI. DRAWING LIST AND VENDOR'S LITERATURE 2412-1-900 1217-614, Rev. 1217-615 1217-642, Rev. 1217-644 1200-107, Rev. 1200-110, Rev. 1200-123 1200-641 1200-642 51X3451-03 1200-596 1200-618 1 1 1 Bui. 10CAA25:215-1 60B1588 T4200-123, Rev. C *24-700087-00 *Bul. E-53 General Assembly Support Structure Support Structure Erection Arrangement Erection Support Structure Shaker Walkway Cell Plate Walkway Ladder Standards Sections - Shaker Mechanism and Tube Suspension Arrangement - Shaker Mechanism and Tube Suspension Allis-Chalmers Motor Instructions 12" Mader Slide Gate Installation of Manometers and Fittings for Pre-Engineered Dust Collectors Meriam Clean-Out U-Type Manometers Typical Wiring Drawing for Intermittent Dust Collector Single Cycle Timer (NCC) Dwyer Outline Dimension Dwyer Low Differential Pressure Switches *Revised 7/19/76 II INTRODUCTION II. INTRODUCTION This document contains information on the installation, operation and servicing of Wheelabrator-Frye air pollution control equipment purchased in February of 1976 by ASARCO Incorporated under Wheelabrator-Frye Contract No. 2412 and Customer Order No. 16H-0348. Thip unit will be installed at ASARCO Inc., El Paso, Texas. HI SYSTEM DESCRIPTION xaeumssaca K- m III. SYSTEM DESCRIPTION The air pollution control equipment ordered under this contract uses a Wheelabrator-Frye "DUSTUBE" Dust Collector for the filtration of solids sus pended in gas. In this process, large fans suck the dust-laden gas or air into cloth filter tubes (DUSTUBES) and force-filter it through the fabric to the outside. Intermittently the fans are shut down and the filtered dust is removed from the inside of bags by the shaker mechanism. The dust collecting unit ordered under this contract is designated as a single module. Size 1217F, Model 171, Series 5S with 3,916 sq. ft. of cloth area. This equipment is designed to filter 8,000 ACFM of coke breeze, lime, sodium sulphate, sodium bicarbonate, return salt, etc., dust laden air at an air-to-cloth ratio of 2.04:1. The specific items of equipment ordered under this contract are related as follows: Module Construction: #10 Gauge H.R.S. wleded, stiffened to withstand 20" w.g. Painted on outside surfaces with high temperature primer. Three section fabrication '(upper, lower, and hopper). One piece shop assembled for rail shipment. Upper housing with pre-installed tubular shaker mechanism. 24" flanged outlet stub, roof mounted. Lower housing with snap ring cell plate floor welded air tight. 20" x 48" hinged access door. Sidewall tube relief. 12" access walkway. Hopper with 60 side slope. 12" x 12" flanged discharge as noted above. 18" x 30" bolted access door. 24" flanged stub inlet. Internal air diffusion plate. Shaker Assembly: 2 H.P., 1800 RPM, TEFC 230/460 volt, 50 cycle, 3 phase shaker motors. V-belt drives and guards. Motor mounting brackets and eccentric shaft assemblies. Field Material: 10" individual compartment'U-tube manometer with 25' of tubing. Necessary nuts, bolts, and gasketing required for field assembly. swa 2- - Service Platforms: 30" wide walkways fabricated from 1" x 3/16" bar grating. Bar and rod handrails conform to OSHA regulations. One shaker level walkway. One access door level walkway. All walkways shipped for field assembly. Access Ladder: -' Caged access ladder provides access to shaker and door level walkways from grade to conform to OSHA regulations. Support Steel: Support structure designed to support module(s) with 8T-0" clearance under final discharge valve. Steel designed with cross bracing for 100 MPH wind load. Seismic Zone 3, and 40% hopper loaded with dust weighing 75 lbs. per cu. ft. See general arrangement drawing for column spacing. DUSTUBES: (204) Woven Cotton Sateen Style 101-02 Siliconized Surface 5-1/4" dia. x 171" long with strap top Maximum operating temperature - 180F 9.0 oz./sq.yd. 10-15 CFM permeability Snap ring bottom cuff Timer: One (1) polyflex timer in NEMA XII enclosure. Slide Gate: One (1) 12" sq. manually operated slide gate. The Purchaser will provide the following materials or services: Receiving, unloading and storing material at jobsite. All federal, state and local taxes. Building permits and clearances. All building permits, clearances, and FIA system approval license fees for state and local agencies. Erection and installation labor, including bags. Foundations, including anchor bolts. Means of conveying collected dust from final discharge valves. Electrical wiring. (If WFI control panel included, purchaser need only furnish electrical wiring between control panel terminal strips and remote electrical equipment.) Ventilation piping, hoods and ductwork. Control panel, including starters, pushbuttons, relays, operating lights transformer and a line disconnect switch. Air moving equipment. In sizing fan, allow 6" SPWG pressure drop across dust collector. Inlet ductwork. Outlet ductwork. 3 Weather protection for equipment where required. Means of preventing condensation, including insulation or auxiliary heat, if required. Temperature contorl instruments. All other items not specifically detailed and listed in our technical proposal. Efficient DUSTUBE Fabric Filter Collectors Wheelabrator-Frye Dustube series fabric filter dust collectors are the result of over 35 years' experience in designing and man ufacturing more than 6,000 units. Unit size has ranged from as small as 500 cfm up to 5,000,000 cfm ... the world's largest fabric filter dust collector. Dustube collectors are operating in vir tually every type of industry. This wide experience is not limited to design and manufacture. It in cludes in-house engineering and testing facilities, and in-house filter tube manufacturing. This total expertise permits the Air Pollution Control Division of Wheelabrator-Frye to offer Dustube collectors which will meet the most stringent air pollu tion control codes, and yield uniform collection efficiencies over 99% ... on any dry dust, regardless of particle size. 9 ways better 1. Maximum Efficiency Maintained High efficiency is uniformly con stant throughout wide variations in particle size, filtration velocity and dust loading. 2. Maximum Cloth Life No metal touches or abrades the filtering area of the cloth tubes. Because the tubes are adjust able, the cloth can be properly tensioned. The unique Dustube shaking action is highly effective without subjecting the cloth tubes to unnecessary strain. 5. No Bridging or Clogging Cloth tubes are of 5Va -inch diam eter with flexible walls. This feature, combined with the pat ented Dustube shaking mecha nism, prevents clogging or bridging in even the most severe applications. 6. Simplified Cleaning No auxiliary reversing fans or expensive compressed air is required because of the high efficiency of the Dustube shaking mechanism. 7. Lower Power Costs The Dustube design gives mini mum static pressure loss, result ing in lower H. P. requirement. This is due to ample expansion areas on both the clean and the dirty airsides, plus high efficiency of the shaking mechanism. 3. Simple Installation and Maintenance One man working alone on the clean air side can install or replace tubes. No special tools are required. Cloth tubes can be replaced in groups during off hours, causing no interruption in the use of the unit. Bag changeout time is minimized. COVER: Three-module, size 1224F, Model 171 Continuous Automatic Dustube Collector. 4. Easy Inspection A walkway is provided on the clean air side of each collector module. Inspection can be made during operation in many applications. i 8. Handles Hot and/or Corrosive Gases Dustube collectors are readily applicable in severe heat installa tions such as glass furnaces, cement kilns and coolers, and electric arc furnaces ... with temperatures up to 550F. 9. Research and Testing Tests can be run on dust and fume samples in the Wheelabrator-Frye laboratory to deter mine air-to-cloth ratios, back pressure, bag shaking cycles and general compatibility of the Dustube collector to the sample. 2 Economical Standard DUSTUBE Module The 5-inch Dustube collector is available as an all-welded module in three sizes, and two tube lengths. All units are supplied with cell plates and shaker mechanism factory assembled and inspected to ensure minimum field erection costs and proper alignment of all components. Modules can be shipped as either a completely-welded, onepiece unit; or as three separate sections for easy handling in tight erection areas. When shipped as three sections, the hopper, lower housing and upper housing are shipped with all internal compo nents mounted. Only two field joints are required to complete assembly. Factory assembly and inspection ensures trouble-free operation. Standard construction is 10gauge plate, stiffened for 20-inch WG. operating pressure (the strongest in the industry). Sup port steel is available as a stand ard option, with either four-foot or eight-foot clearance below the hopper discharge valve. External walkways and ladders are avail able to provide access at the housing door and shaker mecha nism levels. All walkways and ladders meet rigid OSHA requirements. Hinged access door dimen sions of 20- x 48-inch are stand ard on all Dustube modules. All modules are supplied with onepiece, die-drawn cell plates for use with snap-ring tubes. The shaker mechanism is a heavyduty, tubular type. For ease of inspection, all moving parts are located outside the module. A complete range of auxiliaries such as control panels, inlet and outlet valves, and hopper dis charge valves, is available. UNIT MODEL N* OF BAGS SO FT /CLOTH AREA APPROX WT /UNIT (SEE NOTE Nt 5) A B C D E F G H J K M N P 0 R S T U V w X Y Z 1224-F 126 288 4032 9.187 12-6%" 6-3J4," 15-9%' I9'-93/s 10-7%" 171 288 5530 10.422 12-6%" 6-3%" 15-9%" 19-9%" 10-7%" 5-3%' 7-5% 9-0%" 7-5%' l2'-9%" l6'-6%" 28-6%" 32-3%" 32-6%" 6-3" 12-6" 3`-6h 2'-5% 36-3%" 6-3" 12-6" 3-6" 2-5% 6-0" 7'-3" 6-0" 8'-3" 2'-9V 28 V 2'-S>V 28 j 2-9%' 28 'V 2'-9%' 28 X1 V 2-6" 1 2`-6" 1220-F 126 171 240 240 3360 4608 7,700 ICf-6%" 8.830 IO'-6%" 5'-3%" 5,-3%" l4'-0%" 14-0%" 18-0%" 18-0%" s'-io5/," 8'-l0%" 5-3%" 7-5%" 9'-0%" 7'-5%" 12'-9%" l6'-6%" 26'-9%" 30-6%' 30-9%' 34-6%' 5-3" 10-6" 3-4" r-n%" 5-3" 10-6" 3'-4" i'-iiW 5-0" 5-0" 7-3" a-3" 2'- 3%' 2'-3%" 20 V 2'-6%" 20 X 2-6%' 24 V 2'-3" 24 'V 2-3" I2I7-F 126 171 204 204 2856 3916 7.160 9-6V 4-9%" 8,196 9-6%' 4'-9%" l3'-2%" 13-2%" 17-2%'' 17-2 V 8'-0%'| 8'-0%" 5'-3%" 9'-0%" 7'-5%" 7'-5%" 12-9%' 1 16'-6%' 25'-ll%! 29-8%" 29-11%`| 33-8%'' 4-9" 4-9" 9'-6" 9'-6" 3-2" 3-2" 1-7%" f-7%" 4-6" 4-6" 7-3" 8-3" j 1-! 1V 20 [ Vl 2-3%' i 20 j 20 'V 2'-3%'' 20 Me'' i X 2-0" i 2-0" Note: Dimensions are subject to change without notice. 9" Slide Gate Assembly 9" Rotary Valve Assembly /t c e l l p l a t e . 4 Reliable Large-Volume Standard DUSTUBE Collectors For the big job, there are largevolume Dustube modules, with all of the features of the Standard Modules described on page 4. Designed for 20-inch WG. oper ating pressure, these modules are shipped in three sections, with all internal components factory-assembled. Only two field joints are required to complete the installation. Support steel, catwalks, lad ders and screw conveyors are all available forthese units, as is a complete range of auxiliaries. Front View 5 mmsmmm .ate & Walkway Plan {INSIDE HOUSING) r UNIT MOOEL N* OF BAGS SQ.FT./CLOTH AREA "APpftOx Wt/unii (SEE NOTE N* 4) A B C 0 E F G H J K M N P 0 R S T U V w X Y 2 AA BB CC DO EE 1244-F 126 528 7.392 171 528 10,138 15,673 23-7 17,512 23-7 -- 13-4'/, 17-414 -- 13-47, 17-4% 13-8?, <7-8% 13-8% 17-8% 6-3% 10- 3% 7-07, 6-3% 10-3% 7-0% 6-10% 10-10% 6-10% 5-5^ 6-97, 12-27, 25-6% 29-6% 6-lo7, 10-10% 6-10% 9-2% 6-97, 15-11% 29-3% 33-3% 25-11% 29-11% 5-7% 2-8 2-11% 18-0 29-8% 33-87, 9-4% 2-8 2-117, le'-o 3-6 8-0 5-0% 6-5% 23-0 3-6 6-0 5-0'/z 6-5% 23-0 1252-F 126 624 8.736 19,480 27-7 171 624 11,980 21,489 27-7 -- 13-47, -- 13-47, ir-47, 17-4^ 13-8% 13-8% 17-8% 17-8% 6-3% 6-37, 10-3% 10-3% 7-0% 7-0?, 6'-10% 6-10% I0'-I0% 10-10% 6-10% 6-10% 5-5% 9-27, 6-97, 6-97, 12-2% 15-11% 25-6% 29-3% 29-67, 33-37, 25-11% 29-8% 29-11% 33'-8% 5-b7, 2-8 9-57, 2-8 2-11% 22-0 2-11% 22-0 5'-6 8-0 5-6 8-0 7-3 7-3 6-3 27-0 6-3 27-0 1260-F 126 720 10,008 171 720 13,824 21,601 24,011 31-7 31-7 15-9% 15-97, 13-47, 13-4'/, 17-47, 17-47, 13-87, 13-87, 17^8% 17-8% 6-3% 10-37, 7-07, 6-10% 10-10% 6-107, 6-3?, 10-3% 7-0?, 6-10% ICt-10% 6-10 7, 5-5% 9-2% 6-9% 6-9% 12-27, 15-11% 25-6% 29-3% 29-6% 33-3% 25-11% 29-11% 29-8% 33-8% 5-8% 9-5 7, 2-8 j 2-8 2-11% j 2-11% 26'-0 j 26-0 5-6 j 5-6 10-0 j 10-0 5'-2 I 5-2 10-4 1 10-4 31-0 j 31-0 Note: Dimensions are subject to change without notice. Side View 6 Dependable Continuous Automatic DUSTUBE Collectors The Standard 5-inch modular Dustube collector (described on Cloth Area Model 126 pages 3 & 4) is designed for use in continuous automatic service. [ 1217 F I 1220 F | 1224 F i No i 204 Bags 240 Bags 1 288 Bags: Standard components offer an 1 2,856 3,360 4,032 ' automatic collector with net cloth 2 5,712 6,720 8,064 ' area from 5,712 sq.ft. (3 module, size 1217F, Model 126) to 49,770 sq.ft. (10 module, size 1224F, Model 171). These standard modules are available with pyramid or semi trough hoppers, and either screw conveyors or individual rotary 3 4 5 6 7 8 9 10 8,568 11,424 14,280 17,136 19,992 22,848 25.704 28,560 ' 10,080 13,440 ' 16,800 20,160 23,520 26,880 30,240 33.600 12,096 16,128 , 20,160 ; 24,192 28,224 ` 32,256 36,288 40,320 . discharge valves. Support steel is available to provide either four-foot or eight-foot clearance under the final discharge valve. Inlet and outlet valves with automatic actuators are available to isolate each module for cleaning. collector system. Standard control panels are available which will automatically guide the collector through its complete cleaning cycle. These control panels can also control exhaust fans and screw con Inlet and/or outlet manifolds veyors; as well as actuating the can be furnished to provide a damper valves and shaker single connecting point to the mechanism. A safety lock-out Cloth Area Model 171 [ T" 1217 F ; 1220 F ;no. ' 204 Bags ' 240 Bags 1: 2` 3,916 7,832 4,608 9,216 3 14 ' 11,748 15,664 13,824 18,432 5 19,580 23,040 , 6 23,469 27,648 7 27,412 32,256 ' 8 31,328 36,864 ! 9 35,244 41,472 10 39,160 46,080 1224 F 288 Bags 5,530 11,060 16,590 22.120 27,650 33,180 38,710 44,240 49,770 55,300 switch can be included to allow inspection of any module while the other modules continue through their cycles. Continuous catwalks are avail able for access to the door and shaker mechanism levels. De signed to meet OSHA require ments, they are available with caged access ladders. A typical Continuous Automatic Dustube Collector. mm Pre-Assembled DUSTUBE Collectors Model 70-AC&112-AC Pre-assembled Dustube collectors are compact, economical unit-type fabric filters. Units are shipped completely assembled. They offer the quickest and easiest field installation. Units combine the efficiencies of the basic Dustube design with the added advantage of requiring no field assembly. Several preassembled units may be installed together, rather than one large central collector, making further savings in installation costs and economizing in ductwork and power requirements. t | j: \ ( ; '( Specifications ; Size ' Sq. Ft. o! Cloth ` i i 70AC 112AC 3 ! 274 N.A. 1 4 . 365 N.A. Capacity C.F.M. @ 3:1 70AC ' 112AC 822 N.A. 1095 N.A. NoTubes 36 48 No. -- of Hop- Lgth. Width - pers "A" "B" 1 3'-6" 3'-6" 1 4-'-6" 3'-6" Refer To Lettering On Drawing -C" Inlet "D" Outlet 70AC 112AC 70AC 112AC 7" Dia. N.A. 9" X 12" N.A. 9" Dia. N.A. 9" X 12" N.A. '6 8 547 893 1641 2679 72 2 6'-6" 3'-6" 10" Dia. 13" Dia. 9" X 18" 730 1190 2190 ' 3570 96 2 8'-6" 3-6" 11" Dia. 14" Dia. 9" X 18" 9" x 18" 9" x 18" : 5D 912 1488 2736 4464 120 4 5'-6" 6'-6" 13" Dia. 2@11" 9" x 18" 2@9" x 18" ` 6D 1094 1786 Lij....80 _L 1460 2380 N.A. = Not Available. 3282 5358 144 4 6'-6" 6'-6" 438.0.. f 7140 192 4 8'-6" 6'-6" Add 150 lbs. to determine shipping weight. 14" Dia. 14" Dia. 2@12" 2@14" 9" x 18" 9" x 18" 2@9" x 18" 2@9" x 18" Note: Dimensions are subject to change without notice. Model 70-BC Nef Wt. Pounds : 70AC 112AC 1540 N.A. 1815 N.A. 2255 2711 2585 3165 2985 3660 1 3425 4100 3880 4710 . This is-the smallest and most economical unit-type collector in the line. It features a bin hopper and hand shaker. It is ideal for applications where relatively small volumes of air are to be handled and for light concentra tions of dust, such as small grinder stands and small sandblast cabinets. Model 70-BC collector incor porates the same basic principles and advantages of the larger Dustube collectors. It is ruggedly constructed, simple in design, highly efficient in operation, and is shipped completely pre assembled. Specifications 1----------'.------- i------------------- 1----------:----------j----------------------------------- 1 I , No.Capacity j Sq. I | of ! C.F.M. : No. of ; Ft. ; Dimensions . Size Hop------- | ; Tubes of >, | ; pers at 3:1; at 4:1 [ Cloth Length Width Height Exhaust Connections Inlet - Outlet : Nef Weight 7no. 1 i 1 ; 273 : 364- 12 1 91 ' 1'-10" ' 2'-4" 9'-2'' 4" Dia. 6" Dia. 37S lbs. . i: , No. 2 ; 1 546 ' 728 24 182 ;-2'-4" 3'-4" ! 9'-2" _6" Dia. 8" Dia. 550 Ibs^ 'Note: To determine shipping weight add 150 lbs. Note: Dimensions are subject to change without notice. KEY: A--Exhauster Motor and Fan (Extra); B--Cloth Tubes; C--Inlet; D--Baffle Plate; E--Clean Air Discharge; F--Inspection Door; G--Dust Hopper and Expansion Chamber; H--Clean-Out Door 8 mam Standard Accessories Damper Valves Compartments of continuous automatic-type Dustube collec tors are isolated for periodic cleaning, using one of the damper valve arrangements illustrated. Wheelabrator fabricated square valves are available with wipers of neoprene, asbestos, or other suitable material, depending upon operating conditions which would affect a good seal. These valves are available with either air cylinder operators or electricmotor drives. Plate-Type Damper Valve The Plate-Type Damper Valve has been used dependably on hot, dusty and corrosive gases as well as clean air, giving a tight metalto-metal seal without use of wiper seals. The shaft is constructed of carbon or stainless steel, operat ing in an inert, self-lubricating graphite bearing. Dust Hopper Discharge Valves Three types of dust-discharge valves are available as standard construction with pyramidal hoppers: 9" slide valve, 9" con tinuous dribble valve, and 9" rotary valve. While the 9" size is standard, the valves can be supplied in sizes from 6" to 30" for special collection problems, as in the handling of light, fluffy materials. Screw Conveyors Screw conveyors for discharging collected dusts are available. Rotary valves and dribble valves are often used in conjunction with screw conveyors to provide an air lock while the collector is in operation. Special Controls Various special controls are available for the operation of Dustube collectors, as part of systems designed for specific operations. Temperature Controllers--These thermocouple-type units operate by-pass or tempering air systems in the event of temperature surges on hot applications. Volume Controls--Controlled by pressure-sensitive equipment, they maintain constant volume as the cloth back-pressure in creases. Program Timers--On Continu ous Automatic units, a multiplecircuit program timer continu ously cycles the various compart ments. It can also operate the screw conveyor automatically on a programmed basis. Polyflex Reset Timer--For Dus tube collectors operating on intermittent service the Polyflex assures regular operation of the shaking device, keeping the filter tubes clean, preventing high back pressures, and assuring that the shaker will not be operated while the fan is running. 10 i . For other applications, the Air Pollution Control Division of Wheelabrator-Frye also offers: Ultra-JetFabric Filter Dust '-`Collectors--these are high- -* pressurepulse jet units . . which are available in both standard modules or custom -designed. " >' . Wheelabrator Lurgi Electro static Precipitators--de signed without compromise, these units feature rigid- - ' _ ^frame discharge electrode - systems, and are designed " foreither hot side or cold , a - side applications. Regional Sales Offices: ATLANTA 3456 Hardee Avenue, Chamblee, GA 30341 (404)458-3851 CHICAGO 4415 Harrison Street Hillside, IL 60162 (312)449-8950 - CLEVELAND * ' . 21010 Center Ridge Road, Rocky River, OH 44116 (216)331-1377 ? , , NEW YORK 2816 Morris Avenue, Union, NJ 07083 (201) 686-7223 SAN FRANCISCO 1881 Rollins Road. . Burlingame, CA 94010 (415) 692-5336 CANADA Wheelabrator-Frye Corp. -r of Canada, Ltd. 235 Speers Road, Oakville, Ontario (416) 844-1550 Air Pollution Control Division AL Wheelabrator-Frye Inc* V 930 Ft. Duquesne Boulevard 1 V Pittsburgh, PA 15222, ^ .. (412)288-7300 , ` " o MEMBER ' - a. iGcr . : i. IV INSTALLATION & OPERATION ERECTION INSTRUCTIONS FOR PRE-ENGINEERED DUSTUBE DUST COLLECTORS FOUNDATION The foundation ahould be prepared according to the anchor bolt layout, which Is usually found on the General Arrangement Drawing. Piers or slabs are to be designed by the customer to suit loadings of the collector as indicated on the above drawing and by soil conditions. ERECTION These models are prefabricated and shipped as either one-or three-piece modules with the support steel removed. First, bolt the support columns to the anchor bolts. Then erect the rest of the support Bteel, tightening the bolts only enough to hold the columns in an upright position until the bracing and main frame members are erected. Level and square the framework, with shims under the base plates if necessary, then tighten all bolts and grout under the base plates. If the collector is delivered in three modules, the upper housing, lower housing and hopper should be field connected on the ground by bolting and welding on the inside. Welds must be airtight and no gasketing or cement are used. Lift the Dust Collector module by the lugs provided on the top corners of the main housing, set it on the support steel with bolt holes aligned, fasten bolts loosely, level the module, then fasten bolts tightly. Assemble the walkway and handrail on the ground near the Dust Collector, then lift the walkway into position in front of the access door and bolt the walkway support channel to the side of the housing. Connect the preassembled safety cage ladder to the walkway as shown on the General Arrangement Drawing. The shaker mechanism is held in place for shipping with a hold-down angle that runs the length of the collector. The hold-down angle is to be removed after the collector is in an upright position. Install all DUSTUBES according to instructions. Mount the motor on the motor base and install motor sheaves, V-belt and drive guard. Mount screw conveyor (if any) to bottom of hopper by using cement and gasket. Place inlet and outlet damper valves (if any) in correct position and connect ductwork. By pulling on the V-Belt, manually operate the Bhaker mechanism through several turns to check for proper functioning of the unit. INSPECTION AND MAINTENANCE INSTRUCTIONS FOR DUSTUBE DUST COLLECTOR BEFORE OPERATION 1. Inspect all DUSTUBES from the hopper side for proper sealing against cell plates. 2. Hake sure that there is gasketing and cement (except when welded) between flanges, and that all bolts are tight. 3. Roll the shaker device over by hand to be sure that no parts are binding and that all bolts are tight. 4. See that all tubing and pipe connections are tightly fastened and that all entrances to the housing are sealed airtight. 5. Become familiar with the construction of the timer and its function in collector operation. Follow through the cycle of damper valve operation and 6haker motor operation to assure that they will operate properly. 6. Check the shaking cycle and make any necessary adjustment. STARTING OPERATION 1. Inspect the housing for air leaks and remedy by either tightening the bolts nearby or caulking. 2. After the first day's operation, inspect the cell plate floor for dust accumulation If dust is found recheck the DUSTUBES and cell plate joints in the area.- 3. Watch operation of shaker device for a final check on alignment and adjustment. DURING OPERATION Observe the manometer gauges. The manometers of properly operating compartment(s) should show a uniform difference in the level of liquid in each column. Often, one manometer will have both liquid columns equal (at zero) showing that the compartment to which it is connected is "out" for cleaning. A reading on this gauge indicates a leaky damper valve. The manometer reading of a compartment just before shakedown should be approximately 4 to 6 inches w.g. If manometer readings in excess of 6 inches w.g. are frequently noticed or if the manometer readings differ greatly, it may indicate the following: 1. The damper valve for this compartment has not been closing during the shaking cycle, preventing proper cleaning of the DUSTUBES. 2. Dust has bridged over the hopper outlet, or outlet is clogged with foreign matter, preventing discharge of collected dust. 3. Shaker device is inoperative. DUST COLLECTOR To insure maximum efficiency, the following portions of the collector require care: 1. Housing: The dust collector housing must be maintained in an air and water tight condition. At least once a year all flange bolts should be tightened and seams recaulked whereever leaks are detected. Protection against corrosion is required by periodic painting as needed. Mechanical damage to the housing or other protions of the system must be avoided. 2. Collector Supports: An annual inspection, tightening of all bolts and periodic repainting are required. 3. Doors: Access and inspection doors must be kept tightely closed, except when collector is shut down. Threaded members in clamps, etc., must be lubricated and protected from corrosion. Door seals and gaskets should be maintained in good conditions and replaced when they loose resiliency or become damaged. Door seals and gaskets are not to be painted at any time. A. Automatic damper valves: (In continuous automatic operation) Automatically operated damper valves are provided on each compartment to interrupt the flow of air and permit the DUSTUBES to be shaken. Any passage of air through the DUSTUBES during shaking will seriously interfere with the efficiency of the shaking process, and will result in unduly high back pressure. These valves should be maintained according to manufacturers instructions; and closely monitor the manometer gauges as a check on their proper operation. 5. Damper valve operators: Consult instructions in Section VI. 6. Damper valve linkage: The linkage between the operators and valve shafts must be precisely adjusted at start-up and properly secured to prevent slippage. Corrosion should be prevented and binding eliminated. 7. Shaker Mechanism Lubrication: The eccentric bearings and pillow block bearings of the eccentirc shaft assembly are WHEELABRATOR nevarlube bearings and require no further lubrication. However, grease should be applied to the grease fittings of the clevis and shaker bar pins on a monthly basis. Lost Motion: This requires a visual weekly inspection and a thorough monthly inspection. V-belt shaker drives should be checked for correct tension and wear, or replaced if necessary. Set screws in drive sheaves, bearing collars, etc., should be checked and tightened if needed. Pins and bushing in shaker bars, connecting rods, tie bars, and /or clevis halves should be checked for proper alignment and wear. Shaker bars exhibiting broken welds or other defects should be replaced. All nuts and bolts should be checked and tightened as required at monthly intervals. Wear on knife-edge assemblies or channel brackets and channel bearings should be checked monthly and parts replaced when knife-edge wear exceed 1/8 inch and V-block grooving exceeds 1/16 inch. Any tendency of the knife-edge protion of channel brackets to ride free of the channel bearings should be corrected by realignment of the shaker mechanism. PRESSURE SENSING MANOMETERS OPERATION The effectiveness of almost all Wheelabrator-Frye Dust Collectors is monitored by manometers that compare the air pressure on the dirty air side of the filter fabric with the pressure on the clean air side. When a unit is started up with clean DUSTUBES, the air pressure created by the main exhaust fan on the dirty air side is more than the pressure on the clean air side. This differenceis shown by the levels of colored liquid in the two branches of the U-tube manometer. The end of one of the branches is open to the dirty air atmosphere and the other branch is open to the clean air side. The differences in level are read in inches of water, since the specific gravity of the manometer fluid is the same as water (1.00). The manometer, therefore, is a visual check on the operation of the unit and will immediately detect any malfunction such as a stuck valve or damaged DUSTUBE. INSTALLATION To connect tubing between manometer and housing, see instruction drawing listed on contents sheet under Section VI. It may be necessary to purchase extra tubing so that the manometers can be placed in a more convenient location. The location we suggest is referred to on the instruction drawing. CLEANING ' To clean out the manometer, you remove the top wingnut, drop the Head, remove the two thumbscrews that hold the reading scale, and remove the scale. Then take a small screwdriver and remove the small screw and clip at the bototm, which allows the glass portion of the manometer tc come out. Being careful not to break the glass U-tube, dump out the old manometer fluid and scrub the inside with a small bore cleaning brush and water. All foreign material and stains must be removed and the cleaned tube must be dry before refilling. Then put the glass U-tube and scale back in place and tighten the finger screws almost all the way. The mano meter should now be filled with a funnel approximately up to the zero marks, final fine adjustment made to zero by moving the scale up or down, the scale screws tightened all the way, and the head and wing nut replaced. The tubing can also be disconnected at the head of the manometer and compressed air can be used to blow out the tubing. Small valves are sometimes installed to permit connection of a compressor directly to the line. When there is a bad break, the manometer fluid and dirt can be blown all through the tubing. When this happens, you should remove the manometer and blow out the line to make sure you get all of the dirt and fluid. Then the bags should be changed and the manometer hooked up before resuming operation. Manometers also detect malfunctioning because of improperly operated valves, and leaks in tubing connections. The integrity of the entire unit should be checked thoroughly when a leak is suspected. INSTRUCTIONS FOR CLEANING OR REBAGGING WHEELABRATOR-FRYE FABRIC FILTER AIR POLLUTION CONTROL UNIT Shut down the unit and make sure it cannot be turned on during the cleaning or rebagging process. Let the temperature inside the unit cool down to 1006F. Put on long tight-fitting thermal underwear next to the skin with constrictions at the wrists and ankles. Put on a turtleneck dickie or tie a scarf around the neck. Then put on coveralls and work shoes. Smear all exposed skin surfaces with a water-soluble face cream. Wear a good respirator designed specifically to handle the type of dust and fumes you will be exposed to. A safety supply house should be able to provide you with one suitable for your purpose. If you follow these instructions, you should be protected adequately; but if you have any questions don't hesitate to write or call: Mr. James F. Boyer Manager, Applications Engineering Fabric Filter Products Air Pollution Control Division Wheelabrator-Frye Inc. 600 Grant Street Pittsburgh, Pennsylvania 15219 Telephone: (412) 288-7472 INSTRUCTIONS FOR APPLYING GASKETING AND CFMENT Tohnetoptrhoepemr amtientghodflaonfgeapspulyrfiancgescewmeitnht aandpugttayskkentiinfeg; iscuttothaeposlvtritphse of gasknevSn**1,,17 to fit the flenges with . jUIm, of bte.ke; .tick the g..ketL?to th^Wr * flange surface, being careful to butt the breaks closely together- lLirJh! flenge until it feet, on the ge.ketlng; line-op the bolt JoUe?"i.i""0u' U!>PeC apply washers and nuts; and tighten up on the nuts gradually and evenly until L?,!! u 7 g t 8tld Create an airtiht al. The cement should be applied liberally enough so that it will squeeze out when the bolts are drawn tight. Excess cement must be scraped off immediately after tightening Do not apply cement when below 32 F. SD-7501 V PARTS LISTS oc s a ox u a v Vi .* n u cj a. xg *9 u e 41 t c (I ^ GX r. -- x- us uj v " CS -- p v* 5 V. c t p -a O j* y (X I G--X 9 y y3 < c *9 - o. y C ;i g e - * u --l--OCX G L* W y G VI X S3 ^Q w 1a3-4 xOO G> i-4 >s T> xx y G HH C 1- ICX - -H 6 ;& O *9 UX 1 to -4 I G <H >\ u A C ay n -* tn ' ae : G *rt ' > -4 O M 01 iyn 9 g g aH u H O (A i *e0 xO U Pa v< G P oO u C fl o <9 a u 3W U U Cl. l yo to> a CJ 3U h oy uos GGV o. a y 40 i C *r rt * *-* U *H < Ju* wo CO G J M fl ^ I A .* xw inoGGHyndxH--i XX to bO n *h y - aw oco *i U A 3<rt | A A A H l I Mh u X *9 O 3 AHA U<HH y fH a ah i ,a y G i-t V> 4J , zt 0) u CO y x9 xO . G <0 O i oX LOT) tx 9 c m 3 *o a u y A OHH G I *J CO O y X CL 0) X t4 y --4 r-4 C O >o Gw 9o * XG D G X CL V) yO9 CO a*9 C L* 9 U H G O X G *H 'O T) U A wg -a oe 99 G LPUH G *J O TJ W O G M y9O M O fl} X CL G ol *-* 3 & Li U H T) GC G G X O H G (9 X *- A0 U G 5G W *J HHH L i--4 G O0*-4 to 9 X C APH n ih *j A Ufl o. <M 'O U <H 4J CL OC *9 3 --t r- XG V BSs u uu i X G V. 00 C o C G COX ALL aj: T) a C CG COOK' G 4, *9 (0 I X X -4 S3 3 OH W L-t C/i 9 X C -K LI i --co Lx 1-4 G O X L. CL r > xx _J tc Ho a *9 C Si *> C W fj U o a to -a x 9X cc U. CC U> O G *9 a u lj c 9 &. X G o C 3 ^ L> X 2 i co a *c e li w g G XX lx U 4 3. X 9 cO U i OO G -t --i X G 1 9 -x A3 * -U SeDx to *j D M 5 CWG O A oh Z XX' - kl C 9 v4 -- C L> at l a 3 39 t > a -4 O G 32 CJ LGti--4I X J OO CD i A C LH i x *h o as 3 < Oo ,i eon X 3 9 GX W . i OM U i H 4lH^- J: r -cH^ QO : J X -r4 <N >W -H Q - E CO o UO I WXM s a l4 G o 9> x g uG 3 H r MEN I G H 4 -* xx tn c9 M H OOAbl G O LI H O 4M : h G 1-4 O H A 4i A V) 4 cox: go Ga EB TJHN 5A Q 0) H H H G L. i 9 *9 3 UG (J3 O C G li : XO X G *9 E Li 3 o n 4j G G W O* UH >>A HH<0 9 *9 W Li hv G : uG olx Xl a oo ih ux o ^ O G G xH rt X G LI (I) Lx 3 L H H G G *9 O U X C CL G G C *J 3 X I G fi T) W H > G L C -4 X : -4 -H G G C oCL Xoo xG 5 41 H U L yGG'oax-rs rH a 4J x LI u tn h <l g h >x W -4 LI 5 O-HUH A G U L-i Li 00 G A U 3 U 41 A L N H U X 4i L, G G G G 0) G x XU A00 T030 Ic H i G O *9 C 4*- u G O "9 H G L. C H H C A o. o e g O X to H HW i U) Q *j H 66 A L X C X -X* O *H *9 hI AII) TA3 O LC O H --I x a G 6 Li G G H X IU LI CG GX G *9 . 9G G H X i-4 ' y i-4 Li <n 1g0 oC X - a C N Li 9 10 O U X y ox -9 3G lGi LG> . LI 9 *9 W 00 G X Ca UCLV0 li (q 9 A (Cl *9 9 vH G G r-4 Li 3 G v4 O a V9. OcC aO. OcC CL 0P P Sc 2 LU CD E g 3 F CO o IO r- Q 03 i UJ ^ CD -j 3 F CO C9 Z "s p^ U. u co UrJ "X 1-- F O 3 X CO o < z CD 1 00 L> a -4 e- y o a a i-x I 9 Ll O X 9 <- - \a 2 J T4 9 < Lf G G y cn p. a GG O *9 6 GG 1 uUX xX y G f-l *9 l3i 9a a Li &0 h lh< a . tc o 9 J W) G Lt *9 9 X 4 C 00 i--< y g a H *H >*x rH 3 A 41 x li x a ygg X L AA Q X00 'Ll iG G G Li i--I JXX G G : w jc > 9 0. o Vi 'Ll >, Li i-4 O G rH 1 ^4 ^ X > 2 I -4 lx G CL -- 4l G> G X O ^wG G I GX e- u a a toc a *h Li X 9. X O w l. e C CH G xx 9 li ga x g x a. i 41 H A u xx a *9 Vi li Li rH L* G G Li l >x a i u ay lG G n S 6a co g yE a CL G E y O a y o -4 c y >Li ui co g y o xo oc g ux 6 C X 0-4 y X G y L< O F F O j u X O60 W *9 ^ X 1-4 yi L. L* V. X W X 9 WG a l. , , H O 4J H A o CO - *H O > x o X O X c AA I ** G E <H O Li Li yx' a g cx gyy -- --yG C Ll 9 G 6 ocx y g 9yo no x a. Vi y ax a g i o. a 9 O CD G. L O *9 C C *9 a g G *9 L. O G. L. X r-4 y X X G 1-1 y y G U o g o a lx > G G *9 9y J G co 3 - *9 *9 a li x a e <-x OgE --a-44-Gax --uG4 xG LU -rt rh-t a j C/1 g --c _Qa --oCL, a c li ix sul Las iaE aG*oLu/i was bGau c S *9 3 3 *9 ix g a a E -- *o c f-t aG s; o cCahh a *9 - c x x X C W -x a B. a O O *9 C L> . xo yg a o olin -h i- a u H-o!l u LIL BS CL d u c. o Ll a) x a ^N 9 C 9 a ac vX-w L- E G 5J X ^ x a 9> E AH 1 xx u y a X G C V. r-4 5 B G a ix o yx w n a 4i o. b e. >\i-4 a -4 h- u c CW 3 aa - E 0.3 c n 6 *a a 3 O 9 X r-l < n > a *- CD 3 F CO 3 Q -} Ld-j OCL 0 z JS^SSSSS^J UJ > T U. 1 CoC 5 CC 00 <_J UJ UJ X SNOIIDIIHISNI NOI1VTIV1SNI T punoj sdaqs aqa oxxJ `sSeq nau XXB3SUT ox "*? ayoq aaayd XX33 Eqj jo xsayo syxod ay XTJun gaq aqa gna AjjuoS uaqa `adaqs-^ e oauj guyx-dBUs aqa guxsdBXXOO sqtnnqj inoA qay uy qsnd pus spusq qjoq qayrt rnoaaoq aqa 3B aaniSfia sq3 dSEay) sSuoxd aqa qgnoxqa daxjs aqa guyoEpun Xq >}ooq aqnq aqa moaj dsaas agniSfld 3M3 sAoroax `asxya *z tiotjbxxe^sut ao yoAOUiaj 8uxxnp sgut-i-dEUs aqa saanxsna sqj guygEuiBp pxoab 03 xnJ9^B:> 3s *i TVA0W3H ^X9.3ETP3nimy paoEydax ao paxxadax aq pynoqs saAyeA xadarep Axynsj `JEaw 3aq ^yxBa ox guyxynsax ayoAo guxqaqs aqa guxxnp uoxsuaa gEq aAxssaoxa aq yyxrt 3-iaq^ pus ajByjap aou XXT saanxsna oqx `girpjBqs guxxnp auauijxBdmoo e jyo yaas Xyajaydinoo 30U P sxadwap aqa yy '/Cyaoaaxoo guxuoyaouny aou axa --------------------C-n ^TTHPt V. REPAIR PARTS INFORMATION SHEET The next page contains a list of repair parts that we recommend you keep on hand to guarantee uninterrupted operation of your Wheelabrator-Frye pollution control equipment. If possible, the repair parts should be included with your initial order, both for a better price, and to make sure you have them on hand when you begin operation. Another reason for ordering spare parts with your initial order is the fact that the parts can then be capitalized and written off as depreciation, rather than being counted as a budget expense. The recommended number of spare DUSTUBES and other spare parts is based on the type and size of your unit, the mode of operation, and the actual experience of our customers. We strongly recommend the use of original equipment Wheelabrator-Frye spare parts and our Criswell Division's DUSTUBES and other components because of our patent position and the fact that exact dimensions are critical to the close fitting and efficiency of your WFI Dust Collector. While we will gladly forward any DUSTUBE orders to our Criswell Division, it would help you and us to provide the best possible service if you would please address orders and inquiries for DUSTUBES to this address: Criswell Division, Wheelabrator-Frye Inc. 800 Industrial Highway, P.0. Drawer 32 Riverton, New Jersey 08077 Wheelabrator-Frye will continue to handle and supply all replacement parts other than DUSTUBES from our Mishawaka, Indiana address. Orders and inquiries for replacement parts should be sent to this address: Wheelabrator-Frye Inc., Parts Service Dept. , 600 Grant Street Pittsburgh, Pa. 15219 It will help us provide prompt and accurate service if you will give us the part number, the serial or contract number of the machine for which the part is needed, and the number of the drawing on which the part is shown. Spare parts for item6 manufactued by suppliers other than Wheelabrator-Frye should be ordered direcly from those suppliers. PART V PARTS LIST GENERAL INFORMATION In this section of the manual is a list of recommended spare parts with instructions for ordering these parts through Wheelabrator-Frye, Inc. This spare parts list includes items of W.F.I. manufacture, plus vendor supplied items which we feel you, the customer, should keep on hand to guarantee uninterrupted operation. Also in this section, if applicable, we have included parts lists for items of equipment designed or fabricated by W.F.I. and/or Vendors. These lists should be used in conjunction with reference drawing(s) listed on each parts list and located in Part VI of this manual. Specific details and other information relating to equipment or parts can be best understood by referring to the drawings and instructions included in Part IV of this manual. Quantity 50 50 6 6 6 6 2 6 6 6 6 12 2 3 1 2 A 2 50 50 1 1 1 RECOMMENDED SPARE PARTS LIST SHAKER Part No. 6A02A6 209818 19A206 186183 233061 186235 23306A 186236 2333A7 293555 _ 293529 700563 2935A7 293535 186269 2262AA 229855 1983A6 500059 500080 29A319 29A320 195686 Description DUSTUBES Tube Hooks V-Block Knife Edge Assembly Gasket (for Spacer Box Assembly) Spacer Spacer Box Assembly Felt Seal 1--1/A 1 Dia. Dodge SL--A Bolt Fig. Brg. Shaker Arm Assembly Pin Snap Ring Shaker Bar Assembly Nylon Bushing (Shaker Bar) Eccentric Shaft 1-3/A" Dia. Eccentric Bearing Clevis Half Assembly 1-3/16" Dia. Pillow Block 5/16" - 18 NSC Hex Nuts 5/16" - 18 NSC Self-Locking Hex Nuts End Shaft End Shaft Dyna-V-Belt VI DRAWINGS & VENDORS' LIT. . .............- a .:.v ,.iA -i-j--.v ..m A rtin a th -A a i[w v r< a fttrrn m f ' fr - - M r t r * j n'it j - ; t ^ f<.-...> .y , '- TriiD ^ r tn 'ttT - ir M itf iflu lV ^- " 11 - ' 'lM '-'*"*------- f *-T ifili - J - . ^ - -'t> .- t - - iy -- p 3 -Jnwfc riSuik ALLIS-CHALMERS INSTRUCTIONS L 51 X3451-03 aurtatfrg^g i - nil 'tririrrnrrtfrtrirr inffiMfriiiirf TYPE RGZ --------------, Ke> r,i`"l Width 143T Lentfhl r " 145T 3. 16 1-3/8 6-1 2 182T 184T 1/4 l-3'4 2I3T 21ST 5/16 2-3,8 10-1/2 B 5 12-3 8 6 13-3 B 6-1/2 14-3 8 7-1/2 15-3 8 7-1,2 17-1/2 9 19 2 2-3/4 2-1/2 11/32 4-1/2 3-3/4 i-i/. 2-1/4 2-3.4 2-3/4 3-1/2 13,32 5-7 8 6-3 8 6-5 8 7-1 8 7-7/8 8-5/8 M N-W PU BA KL AM 4-1/8 4-5/8 7-3 8 7-11 16 .8750 7-1/2 2-1/4 10-1/2 8-1/2 4-7/8 9-1/2 2-3/4 9-13/16 9-U 16 1.1250 1/8 2-3/4 12-3/4 5-3/8 10-1/2 6-1/8 3-3/8 11-1/4 6-7/8 n-1/4 1.37S0 3-1/2 15 11 12-1/2 AN 5 6 AO AR 3-3/4 4-1/2 5-1/4 3-3/8 3-7/8 4-1/4 4-3/4 4-3/4 5-1/2 BT 254T 3 8 2-7/8 12-1/4 10-1/4 21-3,8 6-1 '4 Is 256T 12 23-1/8 4-1/8 5 9 8-1/4 9-7/8 9-1/8 13-3/8 13-3/6 1.62$ 4-1/4 17-3/4 15-1/8 16-7/8 6-1/4 6-5/8 7-1/2 284T 286T 264TS 286TS 3/8 3-1 4 14 1-7 8 12 24-5/8 13-1 2 26-18 12 23-1*4 13-1 '2 24-3 4 4-3/4 10-1/2 9-3/8 16-7/8 7-1/2 17/32 4-5/8 5-1 '2 11-1/4 10-1/8 1.875 719-3/4 9 18-3/8 8-1/4 4-3/4 5-1/2 10-1/2 9-3/8 14-3/4 3-1/4 11-1/4 10-1/8 15-1/2 4-3/4 1.625 i/a -- -- 324T 326T 324TS 326TS 364T 365T 364TS 365TS n 12 58 12 3-7,'8 2 16 4-1.4 18 2 12-3/4 27-3/4 14-1/4 29-1*4 12-3 '4 26-1-4 14-1/4 27-3/4 13-1/2 30-7-8 14-1/2 31-7/8 13-1/2 28-3/4 14-1 '2 29-3/4 5-1 '4 12 10-3/8 6-1 '4 6 5-1/4 6 5-5/8 21/32 12-3/4 12 12-3/4 13-1/2 11-1/8 10-3/8 11-1/8 11-1/8 5-1/4 3-3/4 16-5/8 6-1/8 5-7/8 14 ll-S/8 5-5/8 13-1/2 11*1/8 18-1/4 6-1 '8 3-3/4 14 11-5/8 2.125 17-1/8 1.875 2.375 18-1/2 1.675 19-1/4 22-3/4 10-1/2 20-3/4 5-1/4 20-1/2 25-1/2 11-1/2 21-1/2 5-7/8 8-1/2 5-1/4 9-1/4 9-1/6 6 9-5/8 404T 40ST 404TS 405TS 3*4 12 5-5/8 20 2-3/4 15-1/4 36-3/8 16-3/4 37-7.8 10 15-1/4 33-3/8 16-3/4 34-7/8 6-1/8 6-7/8 6-1/8 6-7/8 16-2/8 17-1/8 16-3/8 17-1/8 12-3/8 13-1/8 12-3/8 13-1/8 7-1/4 4-1/4 20-3/8 2.875 20-3/4 2.125 6-5/8 3,8 22-3/8 9-7/8 13 10 7 23-7/8 10-5/8 444T 445T 7/8 6-7,6 17-1/2 42-1/4 19-1/2 44-1 '4 7-1/4 19 13/16 8-1/4 20 14-3/8 15-3/8 8-1/2 3.375 24-5/8 11 31-1/4 26-5/8 14 11 12 7-1/2 447T 444TS 23 47-3 4 22 11 17-1/2 38-1/2 10 7-1/4 21-3/4 17-1/8 19 14-3/8 22-3/4 30-1/8 3-3/4 445TS 5/8 3 19-1/2 40-1/2 8-1/4 20 15-3/8 4-3/4 2.375 447TS 23 44 10 21-3/4 17-1/8 o witftUWaadhMidHiM SECTION 1 STORAGE INDOORS 1. STORAGE PREPARATION Controlled Required: Even temperature, !0*For more above dew point; relative humidity 50'o or less: little dust, no harmful fumes. ATMOSPHERE Partially Controlled Desired: Clean and dry as possible. a. Bearings a. Nothing required, ball bearings grease-packed at factory. b. Shaft, flange surfaces. b. Coat with easily removable rust-preventive Tectyl No. 502-C mfd. by Ashland Oil & Refining Co.. Ashland, Kentucky, or equal. c. Rodents c. Prevent rodents, other small animals from nesting inside motor. d. Long Storage. . . (over 6 months' d. Nothing else required. d. tj Disassemble main parts and clean thoroughly. 2) For open motors (except Super Seal) coat rotor ma chined surfaces with removable aust-preventive film 'Tectyl No. 502-C). 2; Repamt previously painted surfaces before reas sembly. 4) Remove condensation drain plugs (if present), insert silica-gel (dessicant) plugs .in openings. 5) For drip-proof motors, install 1/2-pound bags of siiica-gel in air inlets and outlets. Bags must be visible to insure removal before operation. 6) Cover completely to exclude dirt, dust, moisture, and other foreign materials. If possible, insert motor in strong, transparent plastic bag. Attach moisture indicator to side of motor, place several bags of silica-gel inside, then seal plastic bag. 7) If motor cannot be moved from base, cover all open ings with adhesive plastic cloth and spray completely with peelable plastic. As a bare minimum, cover with heavy water-proof paper bag and tie securely around bottom. 81 If motor cannot be sealed in bag and relative humidity exceeds 50`c. use space heaters (installed inside motor when possible) to keep it at least 10'F above ambient air. 2. STORAGE MAINTENANCE a. Bearings...................... a. Route shaft several revolutions every month. Relubricate ball bearings after each year of storage. b. Shaft, flange surfaces. b. Check condition of rust preventive periodically, recoat as recommended by manufacturer. Tectyl No. 502-C may last 2 years. c. Long storage................ c. Nothing else required. c. 1) Check silica-gel bags and plugs monthly; check weekly if subject to wide temperature variations. 2) When moisture indicator changes color, open plastic bag, remove used silica-gel, and Install fresh bags. Reseal plastic bag. 3) Check operation and setting of space heaters. It is important they function properly. 3. SERVICE PREPARATION a. Cleaning................... a. Remove any spilled oil, water, dust, and dirt from interior and exterior. Wipe exterior. Blow out interior with low pressure air or hand bellows. Remove magnetic dust and par ticles with permanent magnet. b. Bearings. 1) Remove all covers, plugs and dessicant bags. Remove rust preventive with petroleum solvent (Stoddard sol vent). Replace pipe plugs. RELUBRICATE BEARINGS. Make sure bearings and lubricant cavities are free from dirt and dust. c. Insulation Resistance . . c. Measure insulation resistance of windings by meggering. Refer to Section 4. Maintenance. Figure 1. Motor Storage Procedures (Indoors) OUTDOORS STORAGE PREPARATION INLAND Dry Humid Usual (Conditions Dust, sand, sunheai. oc casional rain and snow Dust, sand, sunheat. rain, snow, organic (fungus) growth Salty or Industrial Atmosphere Salt (other chemical)-laden moisture and dust, sand, sunheat, rain, snow, fungus growth, fumes, coal chemical dust, soot a. Bearings........................... a. Nothing required: ball bearings grease-packed at factory. b. Shaft, flange surfaces. . b. Same as for indoor storage. c. Rodents............................. c. Same as for indoor storage. d. Long storage d. Over six months ` Over one month Consult Norwood Plant for specification of protective coating for internal parts. Other' wise, take following precautions: 1) Same as indoor storage, refer to 1, dll. 2). 3). 2 Spray all internal surfaces of open motors with one coat anti-fungus varnish (P. D. George No. 11137 protective sealer, or equal). 3) If motor can be moved, seal as for indoor storage, refer to 1. d 4) thru 8). 41 Provide roof or shed to protect from direct rain, snow, punheat, sand storms. 5) If space heaters are not used, install dessicant plugs and bags in all motors. 5. STORAGE MAINTENANCE a. Bearings........................ a Rotate shaft several revolutions at one month intervals. Relubncate ball bearings after each year of storage. Refer to Section 4, Maintenance. b. Shaft, flange surfaces. . b. Same as indoor storage, refer to 2. b Outdoor life of Tectyl No. 502-C is approximately one (1) year. 1) Life of rust-preventive de creases in salt, acid, or alkaline atmosphere. c. Long Storage Same as indoor storage, refer to 2. c, U thru 3j. Check dessicant weekly. 6. SERVICE PREPARATION Same as for indoor storage, refer to 3. a. b, c. Remove anti-fungus varnish in accordance with manufacturer's recommendations. i A motor is in storage when: A. It has been delivered to the job site and is awaiting installation. B. It has been installed, but regular operation is delayed pending completion of plant construction. C. There are long, idle periods between operating cycles. D. The plant (or department) is shut down. Figure 2. Motor Storage Procedures (Outdoors) NOTH: The information contained in this book is intended to assist operating personnel by providing information about the general characteristics of the purchasedequipment; if does not relieve the user of the responsibility of using accepted engineering practices during the installation, operation, or maintenance of this equipment. This book does not cover all design details. When information cannot be found herein, contact the nearest Allis-Chalmers office. (See Directory 25X8109.) "^*W9P)R|ipi rfin fiirvir'Maitnfcnnnniiirtrftiiri' --------L^--~.-a. r>'-Z' " SECTION 2 INSTALLATION LOCATION. Select a location for the motor and driven unit that will: a. Be clean, dry, well ventilated, properly drained, and provide accessibility for in spection, lubrication, and maintenance (see dimensions). Out-door installations may re quire protection from the elements. b. Provide adequate space for motor removal without shifting the driven unit. c. Permit the motor to safely deliver adequate power. Temperature rise of a standard motor is based on operation at an altitude not higher than 3,300 feet above sea level. FOUNDATION. Concrete (reinforced as nec essary or required) makes the best foundation, parti cularly for large motors and driven units. In suffi cient mass it provides rigid support that minimizes deflection and vibration. It may be located on soil, structural steel, or building floors, provided the total weight (motor, driven unit, foundation) does not ex ceed the allowable bearing load of the support. Allow able bearing loads of structural steel and floors can be obtained from Engineering Handbooks; building codes of local communities give the recommended allowable bearing loads for different types of soil. Before pouring, locate foundation bolts by use of a template frame and provide secure anchorage (not rigid). It is recommended that a fabricated steel base be used between motor feet and foundation. See certified drawings of motor, base, and driven unit, for exact location of foundation bolts. Allow for grouting base when pouring. Cast the base foot pads level and in the same plane. If vibration or noise will be objectionable (as in office buildings), it may be advisable to use vibration dampeners between the motor, driven unit, and foun dation. MOUNTING. Motors listed in these instruc tions may be floor-, wall-, or ceiling-mounted. When wall-mounted the shaft may be at any angle, provided external thrust is not transmitted to, nor absorbed by the motor bearings. Mount the motor base (if used) on foundation or other support. Shim as required to level (vertical if wall-mounted). Use spirit level (check two directions at 90) to insure motor feet will be in one plane (base not warped) when base bolts are tightened. Set motor on the base, install nuts and snug - DO NOT TIGHTEN. NOTE: Base mounted assemblies of motor and driven unit are aligned at the factory. However, experience has shown that bases, no matter how rugged or deep in section, will twist during shipment. Therefore, the alignment must be checked after mounting. ALIGNMENT. Reliable, trouble-free, and ef ficient operation of a motor-driven unit depends on the correct alignment of motor and driven shafts. Misalignment may be the cause of: a. Noisy operation b. Vibration c. Premature bearing failure d. Excessive coupling wear Factors that may change the alignment of the unit are: a. Settling of the foundation b. Distortion of the base c. Settling of the building d. Shift of motor or driven unit on the founda tion e. Temperature differences causing difference in shaft heights. The following checking procedure applies to a ball bearing unit, consisting of motor, flexible coup ling, and a driven component mounted on a common base. Although applicable to all types of flexible coup lings, it is primarily intended for the pin and rubber bushing type. For other types, where the procedures differ, refer to the coupling manufacturer' s Installation and Maintenance Instructions. Check alignment as follows: NOTE: This procedure IS for motors not requiring on off set height toallow for temperature rise of the driver. In such cases, see Extreme Service. a. Disconnect the coupling halves. b. Test for parallel and angular alignment one plane at a time (horizontal and vertical) with a dial indicator as shown in Figure 3. Proceed as follows: (1) Scribe index lines on the coupling halves (as shown) or mark where the indicator point rests. (2) Set indicator dial to zero at starting point. (3) Slowly turn BOTH coupling halves so that indicator point remains on the mark. (4) Observe dial reading 180 from start. (5) Acceptable parallel alignment occurs when the total indicator reading does not exceed 0. 004 in. Acceptable angular alignment occurs when the total indicator reading does not exceed 0. 004 in. /ft. (radius to dial indi cator = one foot). Correct excessive parallel and angular misa lignment by inserting shims under motor feet and/or driven unit feet. Retest alignment after each change. For additional alignment information, see factory in structions 51X1175. DRIVE SYSTEMS. Successful motor operation depends on proper selection of the drive. The accom panying NEMA Standard table lists the minimum re quirements for the various drives. This table assumes that the total belt pull does not exceed one and onehalf times the net belt pull. Further, the service 5 ..... ^^f.ifiifiTttiiiattriii waamam factor is taken as one. Finally, all calculations have been based on the use of standard, high-capacity belts. For long bearing life, the minimum pitch diameters should be avoided, particularly when the load is not smooth and steady. It is important that shaft axes be parallel, particularly for belt or gear drives. ___________________________________________________________________________________________________________________________________ 16985 Figure 3. Test Alignment, Dial Indicator From* Nwmbor U3T W5T 182T 182T 184T 184T U4T 213T 215T 21 ST 254T 254T 256T 256T 284T 284T 266T 324T 326T 364T 364T 36 5T 36ST 404T 404T 404T 40ST 405T 444T 444T 444T 444T 445T 445T 445T NEMA STANDARD MINIMUM DRIVES Hors*pow*r at Synchro now $p*d, Rpm 3600 1h 2-3 3 5 5 7b 7b-10 10 15 15 20 20-25 - 1800 1 lb-2 3 5 7b To 15 Vo 25 30 40 50 60 75 100 125 125 150 150 1200 i lb 2 3 5 7b 10 15 20 25 30 40 50 60 75 100 125 900 fbc i ib 2 3 5 7b 10 15 20 2$ 30 40 50 60 75 100 V*b*lt SH*ov* ntional Narrow A, 8, C, D and ($** Not* 1) 3V, 5V ond 8V ($* Not* II) Minimum Pitch Diamct*r, Inch** Moximum Width Minimum Outsid* Diam*tcr, Inch** Maximum Width 2.2 2.2 2.4 2.4 2.4 2.4 2.6 2.4 2.4 2.4 2.6 2.4 3.0 3.0 3.0 3.0 3.0 3.0 3.8 3.8 3.8 3.8 4.4 4.4 4.4 4.4 4.6 4.4 4.6 5.0 5.4 6.0 S** Not* III 6.8 6.8 7.4 8.2 9.0 4.4 4.4 5.2 6.0 6.8 6.8 7.4 8.2 8.6 Not* IV 9.0 9.0 10.0 10.0 11.5 8.0 8.4 8.6 10.0 10.5 11.0 10.5 11.0 12.5 12.5 10.0 9.5 9.5 10.5 12.0 12.0 10.5 NOTE I NOTE II - As covered by Engineering Standards - Specifi cations for Drives Using Multiple V-Belts (A, B, C, D and E Cross-sections)*, dated January 1964. As covered by Standard Specifications for Drives Using Narrow V-Belts (3V, 5V and 8V CrossSections)*, dated July 1964. NOTE III - The width of the sheave shall be not greater than that required to transmit the indicated horsepower but in no case shall it be wider than 2 (N-W) - 1/4. NOTE IV - The width of the sheave shall be not greater than that required to transmit the indicated horsepower but in no case shall it be wider than 2 (N-W). NOTE V - For the assignment of horsepower and speed ratings to frames, see MG 1-13.02.a andMG 1-13.06.a. Flexible Coupling. Separate the coupling and mount a dial indicator as shown in Figure 3. (Check alignment as previously discussed.) Chain. Avoid use with vertical shafts. In stall so that top (upper side) of chain is driving side. Make certain that sprockets or gears' are in same plane. Use straight edge of sufficient length and check across side faces, both sides of shafts. Observe that chain leaves and enters sprockets straight; there must be no twist or wrack. Observe NEMA limits on pitch diameter and follow recommendations of chain manu facturer. Gear. Accurate alignment and rigid mount ing are essential for a satisfactory gear drive. Pitch diameter and width should not be outside recommended NEMA limits. Check the factory for bearing thrust capacity before installing helical gears. In all cases, gear teeth must be centered with each other, correct ... ------ shaft center distance must be obtained, and gear faces must be parallel (check with straight edge and feeler gage on both sides of shafts). Gear teeth must fully engage, to a depth giving approximately 0.002 inch minimum back lash; avoid engagement so deep that gears will deflect or bind. Test for proper alignment by -rotating motor shaft by hand, checking driven gear for back lash through one complete revolution. Test back lash and face parallelism again after tightening mounting bolts. Flat Belt. Avoid use with vertical shafts. Position pulleys so that crowns are in same plane (if not, belt will be unevenly loaded and may run off pul leys). Install smooth side of belt against pulley sur faces and just tight enough to carry rated load without slipping. Ample width avoids the need for excessive tension. Observe NEMAor belt manufacturer's limits for pulley sizes. V-Bell, V-belt drives are not recommended for belt speeds above 6,500 feet per minute. Use only matched-belt sets. Follow the V-belt manufacturer's recommendations for sheave pitch diameter, or follow NEMA standards. V-grooves must be in line; belts must enter and leave sheaves with no side bending. Tighten just enough to prevent slippage under rated load. Some slipping may be allowed in starting high inertia loads to avoid excessive belt tension. Protect belts from grease and oil. Do not use belt dressing at any time. VIBRATION. After alignment has been com pleted, but before drive is engaged, tighten motor mounting bolts, run motor at no load, and check for vibration. If present and excessive (3500 rpm and above, .001 inch; 1700-3499 rpm inclusive, .0015 inch; less than 1700 rpm, .002 inch), loosen one mounting bolt. If vibration decreases, add shims un til retightening of bolt reduces or eliminates vibra tion. a. When alignment and vibration of motor are within limits, engage drive, run at as low load as possible, and check again for vibra tion. If present and excessive, add shims under driven unit mounts in same manner as for motor. b. Recheck alignment after any change in shims to control vibration. GROUTING. Grout compensates for uneven ness in the foundation and base and distributes the weight of the unit uniformly over the foundation. It also prevents the unit from shifting after mounting and alignment. It is essential that the unit be expertly grouted by use of non-shrinking grout. The mix re quired varies with the type of unit to be grouted, lo cation and amount of grout. The instructions included with the non-shrinking grout package will provide the required information for the proper mix for individual applications. Grout the unit as follows: a. Build a form of plywood or thin planking around the foundation to contain the grout. Support adequately to prevent deformation. b. Soak the top of the concrete pad thoroughly with water before grouting. Remove all sur face water before pouring. c. A recommended mix of grout that is satis factory for most applications is as follows: Dry Mix. One sack Portland Cement. Two parts well graded, clean, dry sand. One-pound bag grout additive. This additive is one way to counteract the plastic shrinkage and settlement of a cementsand mix. To make grout additive, add2grams of unpol ished aluminum powder (Merck Co. #0770. or equivalent, available at local pharmacists) to 1 lb. of clean dry flint sand (50 mesh screen passing 25% preferred). Mix thoroughly and seal in a plastic bag. Keep additive dry until ready for use. NOTE: The effect of the aluminum powder is lost if the min is allowed to stand, uncost, for 45 minutes after adding woter to the dry mix, d. Pour the grout through the openings in the base. While pouring, tamp liberally to fill all cavities and prevent air pockets. The grout thickness under the base must be a minimum of 1 inch. To prevent the base from shifting, fill under the base-plate at least 4 inches under all four edges. Prevent grout from interfering with motor or driven unit mounting bolts to allow shifting of bolts as necessary. NOTE: If pouring and tomping the grout will trap air in some places, temporarily place small diameter tubes (thiclc-walled rubber hose) to provide venting. Remove the tubes after grout has filled the cavity; then pour the remainder. e. After the grout has thoroughly hardened, re tighten the foundation bolts, check the align ment, and connect the coupling halves. Approximately fourteen days after pouring or when the grout has thoroughly dried, apply an oil base paint to the exposed edges of the grout to protect it from air and moisture. DOWELING. Doweling the motor (and driven unit) accomplishes the following: a. Prevents movement. b. Eases realignment if motor is removed from base. c. Temporarily holds the motor, should mounting bolts loosen. Insert the dowels as follows: (1) Check the alignment after the unit has been in operation approximately one week. Correct if necessary. 7 WTBWii W Minn (2} Through opposite motor feet drill through and into the base, holes of a diameter 1/64 inch less than dowel pin. Clean out the chips. (3) Ream the holes in the feet and base to the proper diameter for the pins (light push fit). Clean out the chips. (4) Insert pins to be approximately flush with motor feet. NOTE: It is recommended that driven unit be doweled. Refer to the manufac turer's installation instructions for the procedure to follow. EXTERNAL WIRING. Starting and over-load control devices must be matched to motor rating. For safety or convenience they may need to be in stalled some distance from the motor. Follow the control manufacturer's instructions to make proper installation and connections. Observe the following: a. Connect electrical power supply to conform with National Electrical Code and any local regulations. Line voltage and wire capacity must match motor rating stamped on the nameplate. b. Only when the drive is disconnected, momen tarily energize the motor to check that rota tion is in the proper direction. c. If motor is three-phase type, reverse rotation (if required) by inter-changing any two of the three power leads. If two-phase, inter-change stator leads of either phase, being careful not to inter change leads from one phase to the other. EXTREME SERVICE. If motor application is abnormal (high temperature, extreme vibration, etc.), consult Norwood Plant for special instructions for installation. In all cases where a foot-mounted motor is direct coupled, check vertical alignment (par allelism) of coupled drive as follows: a. Operate unit until normal temperature is reached (may require lto2 hours). b. Shut down motor and lock out switch. c. Mount dial indicator as in Figure 4. d. Rotate shafts, noting readings at 0C and 180' (top and bottom). If within 0. 004 inch total indicator reading, or other limit specified by Norwood Plant, unit is satisfactory for operation. e. If not within limits, add or remove shims as required to raise or lower motor. f. If shims are changed for high temperature operation, repeat parallel and angular align ment procedures. < Figure 4. Check of Vertical Alignment 16986 8 mm msmmm --. - 4 . v.>r^.eAS/3^.*jl ^w^^^aP^ggg J-:>' SECTION 3 OPERATION INITIAL START. After installation is com pleted, but before motor is put in regular service, make an initial start as follows: 1. Motor starting, and control device connections must agree with wiring diagrams. 2. Voltage, phase, and frequency of line circuit (power supply) must agree with motor nameplate. 3. If motor has been in storage, either before or after installation, refer to Section I for instruc tions to prepare for service. 4. Check motor service record and tags accompa nying motor to be certain bearings have been properly lubricated. When shipped from the factory, ball bearings have been lubricated to give six months satisfactory service. 5. If possible, remove external load (disconnect drive) and turn shaft by hand to insure free ro tation. This may have been done during installation procedure: if so, and conditions have not changed since, this check may not be necessary. a. If drive is disconnected, run motor at no load long enough to be certain that no unusual con dition develops. Listen and feel for exces sive noise, vibration, clicking, or pounding. If present, stop motor immediately. Inves tigate the cause and correct before putting motor in service. b. If drive is not disconnected, interrupt the starting cycle after motor has accelerated to low speed. Carefully observe for unusual conditions as motor coasts to a stop. Repeat several times if necessary. CAUTION Repeated trial starts can overheat the motor (particularly for across-the-line starting). If repeated trial startsore made, allow sufficient time between trials to permit heat todissipate from windings or rotor to prevent overheating. Starting currents are several times running currents, and heating varies as the SQUARE of the current. 6. When checks are satisfactory, operate at minimum load and look for any unusual condition. Increase load slowly to maximum: check unit for satisfac tory operation. NORMAL OPERATION. Start the motor in ac cordance with standard instructions for the starting equipment used. Some loads should be reduced to the minimum, particularly reduced voltage starts, and or high inertia connected loads. a. Run high temperature motors (Class H insu lation) at reduced load until bearings reach operating temperature. VOLTAGE REGULATION. Motors will oper ate successfully under the following conditions of volt age and frequency variation, but not necessarily in accordance with the standards established for opera ting under rated conditions: a. When the variation in voltage does not exceed 10% above or below normal, with all phases balanced. b. When the variation in frequency does not ex ceed 5^ above or below normal. c. When the sum of the voltage and frequencyvariations does not exceed lO1^ above or below normal (provided the frequency variation does not exceed 5%). NOTE: If motor has more than three leads, the connection diagrams ore usually stamped on the name plate "CM or on a separate connec tion plate \MANUFACTURING INFORMATION MECHANICAL CHARACTERISTICS | Cor - " 1( --- 33PE lift m cy ! : ...J t NAORWOIAONDLDnLOUHIsCISOTn-ICONHAMMLOAOMTCOEINRURSS--AHmfmMIlItfI\rjlmfItlnlZll--1,"9-------".J)iit o\ .mELECTRICAL f MMs.rCHARACTERISTICS | BEARINGS j u1 hItfl"SJJ nil1111 1 f | T --i rmmusi--t i mwm | I OESIGN CHARACTERISTICS INSULATION SYSTEM Figure 5. Hating Plate. 17101 ee: im liiiwji TROUBLE SHOOTING. Between regular maintenance inspections, be alert for signs of motor trouble. Common symptoms are listed in the follow- ing table. Correct any trouble immediately and AVOID COSTLY REPAIR AND SHUT DOWN, SYMPTOM 1. Fine, dust under coupling em ploying rubber buffers or pins. 2. Motor won't start. 3. Excessive hum. POSSIBLE CAUSES Misalignment. CURE Realign set. Usually line trouble - single-phas ing at starter. Improper connection. Load too heavy. Disconnect motor to see if it starts without load. High voltage. Unbalanced rotor. Correct. Check source of power supply. DON'T check with motor energized.' Check overloads, con trols and fuses. Check voltage, compare with rating plate data. Check connections with diagram. Reduce load - or replace motor with unit of greater capacity. Check input voltage and for proper connections. Balance with washers on die cast balance lugs. 4. Regular clicking. Foreign matter in air gap. Take out rotor; remove matter. 5. Rapid knocking. Bad bearing; dirt in grease. Replace bearing; renew grease. 6. Vibration. Misalignment. Realign set. Vibration in driven machine. Run Eliminate source in machine, if motor disconnected for check. possible. Or change to a- flexible belt drive may be in order. 7. Vibration - following motor Rotor out of balance, due to holes Balance rotor. repair. drilled or weights shifted . . . new rotor. 8. Motor over-heating. (Check with thermometer - don't de pend on hand). Overload. Measure load; compare with nameplate rating. Check for excessive friction in motor, drive or machine. Reduce load, or replace motor with unit of greater capacity. Single phase. Check current, all phases. Dirt in motor. Check flow of venti Blow out motor. Use solvent on V lating air. wound section if necessary. Unbalanced voltage. Check voltage, all phases. Rotor rubbing on stator. Replace bearings. Open stator windings. Disconnect motor from load to see idle amps balance in all three phases. Check stator resistance in all three phases for balance. Over voltage. Check voltage. Ground. Locate with test lamp or megger and repair. Improper connections. Recheck connections. 9. Bearing over-heating. Misalignment. Realign set. Too much tension in chain or belt Reduce tension to point of adequacy. drive. Excessive end thrust. Reduce thrust from drive or ma chine. Too much grease (ball or roller Relieve supply to point set by manu bearing). facturer. Insufficient lubricant. Add - up to point set by manufacturer. 10 SECTION 4 MAINTENANCE GENERAL. Routine, regular maintenance is the best assurance of trouble-free, long-life motor operation. It prevents costly shutdown and repairs. Major elements of a controlled maintenance program are: a. Trained personnel who KNOW the work. b. Systematic records, which contain at least the following: (1) Complete nameplate data (Motor Ser vice Record). (2) Prints (Wiring diagrams, certified out line, sectional view). (3) Parts list (see rear of this section). (4) Stock of essential parts. (5) List of spare motors in storage. (6) Alignment data (departures from perfect alignment, allowance for high tempera ture). (7) Results of regular inspection (Motor Service Record). (8) Repairs (Motor Service Record). (9) Lubrication data: a) Method of application. b) Types of grease for wet, dry, hot, or adverse locations. c) Stock of lubricants. d) Maintenance cycle by locations (Some require more frequent lubri cation). e) Record for each motor (Motor Ser vice Record). REGULAR MAINTENANCE. Several of the more important items of good maintenance are dis cussed in the following paragraphs. Others should be added when adverse or unusual conditions exist. Inspection. Each motor should be inspected at regular intervals. The frequency and thoroughness will depend on the amount of operation, nature of ser vice, and the environment. Cleanliness. The motor exterior should be kept free of oil, dust, dirt, water, and chemicals. For fan-cooled motors, it is particularly important to keep the air intake opening free of foreign material. Do not block air outlet. Moisture. On non-explosion proof TEFC motors, a removable plug in the bottom center of the motor, yoke or housing, permits removal of any ac cumulated moisture. Drain regularly. Protection Motors operating intermittently in very damp locations should be protected by space heaters. To retard corrosion, grease all machined fits when the motor is reassembled after a mainten ance check. Refer to Section I, Storage. Loading. Guard against overloading. Over loading causes overheating and overheating means shortened insulation life. A motor subjected to a 10c temperature rise above the maximum limit for the insulation will have its insulation life reduced. While somewhat less serious, underloading a motor is improper. It does lower the power factor, which results in higher power cost. Any motor con sistently underloaded should be replaced by one of lower power rating. The amount of work a motor can safely produce is not easy to measure. A rule of thumb for most cases would be: If the input terminal volt age agrees with the rating plate, the amps are equal to, or less than, the rating plate value; and the speed (R. P. M.) is equal to, or more than rating plate spec ification, then themotor is not overloaded and is prob ably developing its rated horsepower. Duty is also part of the H.P. relationship. Motors have a time requirement, which is specified as duty at a given ambient temperature and, horsepower be ing work, produces heat. This "work-heat" added to the ambient heat, then becomes the environment tem perature of the motor. Duty is therefore expressed in time at a given starting temperature. Note: Duty and the ambient temperature cannot be exceeded without exposing the motor to the hazards of overheating. If the starting temperature (ambient) is greater than the rating plate specification the motor out put H.P. should be reduced to compensate; refer to the factory for instructions if this problem occurs. Temperature. An induction motor operating under normal conditions becomes quite warm. Al though some places may feel hot to the touch, the unit will be within guaranteed limits if the unit is operated within the rating plate limits and ventilation is not restricted. The Total Temperature, not the temperature rise, is the measure of safe operation.Operating conditions should be investigated if the total temperature mea sured `exceeds: Class B - insulation - 110C (230CF): Class F - 135CC (275F); Class H - 150C (302CF). *(See "Temperature Measurement Devices" IEEE No. 119) Insulation. Check insulation resistance peri odically. Any approved method of measuring insula tion resistance may be used, provided the voltage across the insulation is at a safe value for the type and condition of the insulation. A hand cranked meg ger of not over 500 volts is the most convenient and safest method. Standards of the Institute of Electri cal and Electronics Engineers, Inc., recommend that the insulation resistance of stator windings at 75 C, measured at 500 volts dc, after one minute should not be less than: Rated Voltage of Machine + 1000 _ Insulation Resistance 1000 ~ in Megohms This formula is satisfactory for most checks. For more information, see IEEE Standard No. 43, "Reccommended Practice for Insulation Resistance Testing of AC Rotating Machinery. " 11 If the insulation fails to meet this standard, the motor may be dried out by heat from a warm air oven, electric strip heaters, heat lamps, or by passing cur rent through the windings. The temperature should not exceed 167F (75C). Remove the bearing hous ings and direct a fan on the motor to carry the mois ture away. For oven drying, a forced circulation type oven rather than a radiant type is recommended. In ra diant type ovens, some motor parts would be scorched or oven burned before the more remote parts reach a desirable drying temperature. When the motor is dried by passing alternating current through the windings with the bearing housings removed, the rotor must be centered in the stator core. Make certain that the air gap is uniform by wedging fiber strips in the lower portion of the gap. A controlled current of the same number of phases and the same or lower frequency is applied to the ter minals. Voltage should not exceed 10% of normal, and it should not cause more than 60% of normal full load current to pass through the windings. A voltage 15% of normal may be applied after the insulation re sistance has reached one-half of the minimum value determined by the formula. The recommended drying out temperature of 167 F (75C) should not be ex ceeded. CLEANING. Clean the motor, inside and outside, regularly. Frequency depends upon actual conditions existing around the motor. Use the follow ing procedures, as they apply: a. Wipe off dirt, dust, oil, water, other liquids from external surfaces of motor. These ma terials can work into, or be carried into, the motor windings and may cause overheating or insulation breakdown. b. Remove dirt, dust, other debris from venti lating air inlet. Do not permit such matter to accumulate near the inlet. Do not operate motor with air outlet blocked. c. Clean open motors internally by blowingwith clean, dry compressed air at 40 to 60 psi. If the conditions warrant, use a vacuum cleaner. d. When dirt and dust are solidly packed, or windings are coated with oil or greasy grime, disassemble the motor and clean with sol vent. Use only high-flash naphtha, mineral spirits, or Stoddard solvent. Wipe with sol vent dampened cloth, or use suitable soft bristle brush. DO NOT SOAK. Oven dry (150 F) solvent-cleaned windings thoroughly before reassembly. e. Windings of SUPER-SEAL (encapsulated sta tor) motors may be rinsed or sprayed with solvent, and immediately wiped dry with a cloth. These windings may be'cleaned with water and a fugitive detergent (ammonium oleate), or common household detergents. Rinse with clean, clear water to remove all 12 detergent. Hot water or low-pressure steam may be used. Wipe excess water from metal surfaces and oven dry at 200 F. f. After cleaning and drying windings, check the insulation resistance. BEARINGS. Long life of bearings is assured only by maintaining proper alignment, proper belt or chain tension, and good lubrication at all times. In correct alignment of solid couplings can cause exces sive load on bearings, and excessive vibration. In correct alignment of flexible couplings can produce vibration and thrust. Misalignment of belt or chain drives can cause thrust or harmful shaft oscillation. Improper alignment of gear drives will produce shock loads and probably bend the shaft. Too much belt or chain tension often causes overheating of bearings. Also, bearings tend to over heat when pulley centers are too close, pulley diame ters are too small, or belt speed is too high. A serious mistake is daily lubrication of bear ings. It is a dangerous practice, particularly when grease is added without removing the drain plug. The excess grease can cause hot bearings and is usually forced into and through the inner bearing cap, to be thrown into the windings. Proper lubrication is de sired, but some under-lubrication is less dangerous than over-lubrication. Lubrication. Prior to shipment, motor bear ings are lubricated with the proper amount and grade of grease to provide six months of satisfactory ser vice under normal operation and conditions. It is good practice, however, to visually check bearing grease of newly installed motors for proper lubrica tion after approximately three months operation. Grease For best results, grease should be compounded from a lithium soap base and a good grade of petroleum oil. It should be of No. 2 consis tency and stabilized against oxidation. Operating tern - perature range should be from -15 F to +250 F for Class B insulation, and to +300 F for Class "F" and "H". Most leading oil companies have special bearing greases that are satisfactory. Relubricate bearings each six months (oftener if conditions require), as follows: MOTOR SPEED (R.P.M.) RELUBRICATING FREQUENCY 3600 1800 OR LESS 6 MONTHS (4, 000 HOURS) 12 MONTHS (8,000 HOURS) Operating environment may dictate more frequent lubrication. 1. Stop the motor. Lock out the switch, particu larly if end shield is to be withdrawn. 2. Thoroughly clean off and remove pipe plugs from bearing housing. 3. Remove hardened grease from drains with stiff wire or rod. 4. Add grease to inlet with hand gun until small amount of new grease is forced out drain. Catch used grease in suitable container. Note: For vertical shaft motors, it is wise to check the inner cap of the top bearing for grease slumping through the bearing and filling the inner cap grease res ervoir. Sinceit isnecessary toremove the housing, this check is best done during periodic shut down inspec tions. (Bottom bearing inner cap should be 2/3 full.) 5. Remove excess grease from ports, replace inlet plugs, and run motor 1/2 hour before replacing drain plug. 6. Put motor back in operation. Replacement. Replacement bearings may be of a manufacture different from that used in the motor. When ordering, specify: a. Identifying numerals stamped on bearing (also manufacturer, if different), b. Tolerance Class ABEC-1, c. Electric motor quality, d. Internal radial clearance AFBMA-3 is stan dard, for all Norwood motors. CAUTION Never use A.F.B.M.A.-O Bearings on en closed motors with Class "F" or "H" insulation. Replace bearings as follows: 1. Remove end shields (bearing housings). Be sure to take out bolts holding inner caps before pulling shields from shaft. 2. Use bearing puller and exert force only on inner race to remove bearing from shaft. 3. Heat new bearing in an oven to 200 F. While hot, slide bearing on shaft, make certain inner race makes firm, even con tact with shaft shoulder. CAUTION Do not subject bearing to impact. 4. Letbearing cool. Pack bearing caps and assemble end shields. Be sure inner caps are clean and secured. Operating Position (Shaft) Grease Quantity Front or Top Rear or Bottom Outer Inner Inner Outer Horizontal Full None None Full Vertical Full None 2/3 Full Full * Except for a thin cylinder (line) of grease around shaft at cap clearance. Parts Identification The drawings in this book are of the standard design. Most of the parts should be easy to identify, if however, there is some deviation from your machine, consult the factory or the drawings supplied with your unit. Order these and other parts, as required, fromAllisChalmers Manufacturing Company, 4620 Forest Ave., Norwood, Ohio 45212, or through the nearest sales office. Give the following information: a. Motor serial number, b. Other data stamped on nameplate, c. Name and number of part (see cross section and parts list), d. Quantity required. RECOMMENDED SQUIRREL-CAGE INDUCTION AND SYNDUCTIONMOTOR PARTS ITEM 1 2 3 DESCRIPTION OF PART Motor Complete............................................................................. Stator Coils with Winding Supplies 3......................................... Bearings....................................................................................... RECOMMENDED MINIMUM STOCK NUMBER OF UNITS IN OPERATION 1 to 4 5 to 9 10 to 20* 10 to 20 0 1 Set 1 Set 0 1 Set 2 Sets 0 2 Sets 2 Sets 1 I Set 1 Set SYNDUCTION, SUPER-SEAL and POXEAL are Allis-Chalmers trademarks. i This column to be used when complete machine is not stocked, a This does not apply for motors with Poxeal encapsulated-stator, in which case one complete stator is recommended. PARTS LIST KEY NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 CATALOG NO. 71000 70520 70510 70660 72014 72320 72014 72054 72004 72330 72220 72220 72270 72040 72090 72080 72003 72053 72013 72013 72220 71010 72210 72340 72220 72220 70930 70900 70960 72270 70910 72220 72220 72220 72220 72220 72260 72250 70930 PART NAME Stator Assembly Rotor Core Shaft, Rotor Key, Square Cap, End - Rear (Stationary) Deflector, Air* Cap, End - Rear (Rotating) Bearing - Rear Housing, Bearing - Rear Seal, Shaft Bolt, Hex Head (Rear Bearing Housing) Bolt, Hex Head (Rear Bearing Cap) Plug, Pipe Plug, End Cap* Bowl, Fan and Grid Fan Housing, Bearing - Front Bearing - Front Cap, End - Front (Rotating) Cap, End - Front (Stationary) Bolt, Hex Head (Front Air Deflector)* Yoke Stator Eyebolt, Lifting Plate, Rating Pin, Escutcheon Bolt, Hex Head (Air Deflector - Rear)* Gasket (Conduit Box to Yoke) Box Conduit Plug - Conduit Box* Plug, Pipe Conduit Box Cover, Conduit Box Bolt, Hex Head (Conduit Box Cover) Bolt, Hex Head (Conduit Box) Bolt, Hex Head (Front Bearing Housing) Bolt, Hex Head (Front Bearing Cap) Bolt, Hex Head (Fan Bowl) Coupling Pipe Nipple Pipe Gasket, Cond. Box Parting * Parts Not Required 1A TYPE RGZ 1R Serial Mo MOTOR SERVICE RECORD Horsepower-----------------------------------------------Type--------- Speed.VoltsAmperesPhaseCycles _ Insulation C!ass_Temperoture Rise*C Frame Size Connection Diagram - Rotor--------------------------------------------------------------------- Stator Owner Order No. MACHINE TYPE Horixontal Vertical ( Moisture-Resistant Open Drip-Proof Q Super-Seal O Totally-Enclosed Explosion Proof Date Installed .Item Mo.. BEARINGS .Date Purchased. SHAFT EXTENSION Ball Roller Size: Front Rear Lubrication Sleeve Length Diameter Internal Thread External Thread Keyway Location Application Date Repaired or Replaced Repairs or Ports Replaced Fault Repaired Total Cost ^*Nome of Part No. Per Manufacturer's Machine No. Rotor..................................... Stator Coils.......................... Bearing, Front ................... Rear...................... Other..................................... Quan. Date Repl. Cost Quan. Quan. Date Repl. Cost Date Repl. Cost Date Checked Bearings Lubrication Excess Heat Excess Noise Speed Voltage Amps Insulation Clean Alignment Vibration Temperature Litho in U.S.A. INSPECTION j 1 i! _______ ,_______ i_______ A ALLIS-CHALMERS NORWOOD, OHIO 45212 IW I4 I k'mr com m a m rt t V r m tii tm nnae m ri MERIAM Clean-out U-Type Manometer MERIAM INSTRUMENT DIVISION THE SCOTT & FETZER COMPANY 10920 MADISON AVENUC CLEVELAND OHIO 44102 USA PHONE (216)281 1100 FILE NO. 100AA25-215-1 Supercedes 100AA25WM:2131 MODEL 10AA25 r r\ DESCRIPTION The Meriam 10AA25 manometer is a versatile, economical instrument for the measurement of pressures, vacuums or differential pressures. The U-tube type manometer is a primary basic standard of pressure measurement. Pressure measurements are accomplished by balancing a vertical head of indicating fluid with the pressure to be measured. As there are no cams, gears or levers to operate in the manometer, the readings obtained are always accurate. VJ r CONSTRUCTION The manometer has a rigid cast aluminum body frame protecting the glass U-tube on three sides. Mounting holes are provided in the frame for mounting to a wall, column or other suitable structure. The clean-out head at the top of the instrument seals the indicating tube legs and also provides for the external pressure connections to the manometer. The manometer head fastens to the body by a single nut and is quickly and easily removed when necessary. This exclusive Meriam clean-out head feature permits cleaning and filling of the U-tube without disconnecting the piping to the manometer head. A 1/4" female pipe connection is provided out the left and right sides of the clean-out head as standard. Pressure connections at rear or top of head can be furnished when specified. Manometer clean-out heads of semi-steel, hard rubber, stainless steel or PVC are available for special corrosive applications. The manometer scale is located between the tube legs and is so formed as to overlap the indicating tubes to provide greatest ease in reading at the meniscus position. The scale is readily adjustable for zero indicating fluid level. Scale is furnished with satin aluminum background with black graduations and figures. The simple engineered method of supporting and sealing the U-tube in this manometer permits easy tube replacement in the field. VJ V. i =J_ = Ao - 3 '= J ~ 111 ^ ft 'i MERIAM Model 10AA25WM J SPECIFICATIONS: Model: 10AA25 Type: U-tube Range: 6,10,15, 20, 24,30, 36, 50 inches Pressure Rating: 250 PSIG Mounting: Flush front, wall Indicating Tube & Packing: Glass, Neoprene Body Construction: Aluminum Wetted parts material: Semi-steel. 303 S.S., 316 S.S., rubber, PVC Scale Finish: Satin aluminum, black graduations Finish: Aluminum body, black crackle enamel head Scale Graduations: A --Linear inches and tenths B --Inches water pressure using mercury calibrated dry C --Pounds and tenths using mercury (PSI) F --Linear centimeters and millimeters G -- Inches and tenths of water pressure using Meriam 827 Red Oil H--Inches and tenths water pressure using Meriam 175 Blue Fluid I --Inches and fifths water pressure using Meriam 295 No. 3 Fluid Accessories: Return Well Model: 934G50 Electric Contact Rod Model: 990AD Bubbler Model: 931Ror931S Line Trap Model: 932Ror932S Micrometering Valve Model: 941A35 Valve & Piping Manifold: 943F100 Pressure vacuum Variator Model: 971A3 Table Mounting Stand Model: 912A Slip On Cover Model: 915C Gooseneck Model: 91 ID Net weight Range inches Weight lbs. ! 6 10 1 15 20 24 1 30 36 50 ! ! 2 3! 3 4 41 5 5 6! Fluids Available: Description Meriam Instrument Mercury Meriam 1000 Green concentrate Meriam 827 Red Oil Nominal Sp Gr 13.54 1.000 0.827 Fluid Requirements: Range Mercury.lbs. 43 Fluid, lbs. FI. Oz, ! 6 1 10 ! .3 i .4 1 -1 ! .1 ! .4 .5 Description Meriam 100 Unity Oil Meriam 295 Red Fluid Meriam 175 Blue Fluid Nominal Sp Gr 1.00 2.95 1.75 15 20 24 30 36 50 .6 .7 .8 1.0 1.2 1.6 ! .2 .2 1... ___ 25 .25 .40 1 .6 .75 ! .9 1Q_1 1.3 1.75 1 r TO ORDER, SPECIFY: 1. Quantity 2. Model & Mounting 3. Range 4. Wetted Parts Material V 5. Scale Graduations 6. Indicating Fluid 7. Accessories 8. Spare Parts -2- 'N i N>/ CONNECTION REMOVABLE MANC IRNACNHGEES A 6 I0%" 1 0 >SV,' 1 5 j l9'/6' 2: !2A3/," Z`i ! zs'/l 2 C *' 35" 36 I41 50 j 55 y.g BcD 2'5 2'/.' 2% '4' a% 25/; 7'A' . 7" --J i- 3/-l 'eV/! -'/I 3v; 2.V,- 2 295/.* 2 4 h 3 Vfe! 'A(. CD ZSC 0 * G;.A'S "wBE - ' RANGES 20 TO SC INCHES INCLUSIVE ARE SULIE0 WlTr- R'BS ON REAR MANOMETER B00>* RANGES e TO IS INCHES INCLUSIVE HAVE DIE CAST BODIES RANGES 2C TO 50 'NCmCS INCLUSIVE HAVE ALUMINUM SAND * > er onmr c FIN SN ' ~ REMOVABLE HEAD BAHEO ^BLACK^RACAuE Ma'nomETCP BOoV- AlUMiNum laCCuE.R M_ERIAL MODEL I0AA25 WM u-type clean-out manometer WALL MC'JNTINC BULLETIN E-53 SERIES 1800* Low DMal Pressure switches lor eeoerel inMsl service compact economically priced switches in 8 standard ranges, set points from 0.15" to 80" w.c. Repetitive accuracy within l% U.L. and c.S.a. listed.F.M.approved. Model 1823 pressure switch. U.L. and C.S.A. listed, F.M. approved. Series 1823 pressure switch. Conduit enclosure removed to show electric switch. W MOUNTING SPUD AND NUT SET POINT ADJUSTMENT SCREW DIAPHRAGM ADJUSTABLE RANGE SPRING SPOT SNAP SWITCH SCREW TTPE ELECTRICAL TERMINALS lONDUIT ENCLOSURE LOW PRESSURE CONNECTION--'A' NPT HIGH PRESSURE CONNECTION--*A'NPT W CONDUIT CONNECTION CRIMPED RiNG Construction and dimensions. Series 1823 pressure switches. Still our most popular pressure switches. Combine small size and low price with 2% repeatability for enough accu racy for all but the most demanding applications. Set point adjustment inside the mounting spud permits mounting switch on one side of a wall or panel with adjustment easily accessible on the opposite side. U.L. and C.S.A. listed, F.M. approved. *Model 1823 shown; (1823 replaces 1820, 1821 and 1822 which are similar). Environmental (MIL) Switch Unlisted Model 1820 can be furnished with special snap switch sealed against the environment for temperatures down to --65 F., high humidity and/or for government applications. Similar to standard Model 1823 except dead band is slightly greater. Specify Model 1820 (Range No.) "MIL" in ordering. Weatherproof Enclosure 16 ga. steel enclosure for unusually wet or oily conditions. Withstands 200 hour salt spray test. Gasketed cover. Weight S`/2 lbs. Switch must be installed at factory. Specify "WP" in addi tion to switch catalog number. Explosion-Proof Housing Cast iron base and aluminum dome cover. Approximate weight 7% lbs. Specify "EXPL" in addition to switch catalog number. How to Order: See price list, Bulletin S-26. PHYSICAL DATA Temperature limits: 32 F. (-30 for dry air, --65 with "MIL" option) to 110 F. (130 with re duced electrical rating). Rated pressure: 10 psig one or both sides of diaphragm. Pressure connections: Vs" NPT. Electrical rating: 15 amps, 120480 volts, 60 Hz. A.C. Resistive Vb H.P. @ 125 volts, 1/4 H.P. @ 250 volts, 60 Hz. A.C. Wiring connections: 3 screw type, common, normally open and normally closed. Set point adjustment: Screw type inside mounting spud. Housing: Aluminum die cast ing. Steel fittings zinc plated, dichromate dipped for 200 hour salt spray test. Diaphragm: Silicone rubber on dacron with aluminum support plate. Calibration spring: Stainless steel. Mounting spud: W pipe thread. Weight: 1 lb., 5 oz. SERIES 1823 SWITCHES: OPERATING RANGES AND DEAD BANDS. U.L. and C.S.A. Listed, F.M. Approved. Model Number 1823-0 1823-1 1823-2 1823-5 1823-10 1823-20 1823-40 1823-80 Operating Range Inches, W.C. 0.15 to 0.5 0.3 to 1.0 0.5 to 2.0 1.5 to 5.0 2.0 to 10 3 to 22 5 to 44 9 to 85 Approximate Dead Band At Min. Set Point At Max. Set Point 0.06 0.06 0.08 0.08 0.10 0.12 0.14 0.28 0.18 0.45 0.35 0.70 0.56 11 1.3 3.0 Suggested Specification Differential pressure switches shall be diaphragm operated with 4" diaphragm to actuate a single pole double throw snap switch. Motion of the diaphragm shall be restrained by a calibrated spring that can be adjusted to set the exact pressure differential at which the electrical switch will be actuated. Motion of the diaphragm shall be transmitted to the switch button by means of a direct mechanical linkage. Switches shall be Dwyer Instruments, Inc. Catalog No. 1823-for the required operating ranges. Patent No. 3.007.017