Document oD8ygkkBBRqKVvLMNNbwQ6Jjo
FILE NAME: Reddaway (REDD) DATE: 1975-7978 DOC#: REDD006 DOCUMENT DESCRIPTION: Unpublished Consultant's Testing Reports
RALPH L. L A N Z
C o n su lta n t
o
5001 Grant Avenue Philadelphia, PA 19114 i Tel. (215) 637-7432 i
November 11 1975
Mr. Vincent LaCarrubba Reddaway Manufacturing Co. 32 Euclid Ave. Newark N. J.
Dear Vincent:
This report covers my visit to your factory on Tuesday November 4 1975. Six samples of airborne asbestos fibers were collected* at that time and all data as well as the results of the analyses are shown on the original data sheets which are enclosed.
Sample R-l. There were a number of places where abrasion of the dry yarn oc
1 curred in this operation and `the result was lower than I expected. While there is
little doubt that the concentration of asbestos fibers in the air was low at the
f
time of test, the true value may have been significantly different than the 0.29
* 5
fibers/cc which was found. This is because the sampling time was not long enough
to give the desired concentration of fibers on the filter. For the best accuracy,
the sampling time should be just long enough to give a count of 100 fibers in 100
fields, or a value of average fibers/field of 1.00.
In practice, good accuracy can be obtained if the value forav. fibers/field is between 0.59 and 2.00; however sample R-l had only an average of 0.11 fibers/field. The accuracy of the result could have been improved by counting more fields, say 500, but this would have been expensive and, in sy opinion, unnecessary since even if the true 'Value were twice as high as the value found (hot likely), the fibers/cc would have been well below OSKA limits.
The desired sampling time can be estimated by dividing 170 by the expected
result for fibers/cc. Thus, the next time this operation is to be sampled, you
would divide 170 by 0.29 and find that sampling should be for 586 minutes. Long
l i
sampling times such as this are generally impractical; about the bast you can do
l
is to sample as long as you reasonably can, about 3 or 4 hours.
Sample R-2. There is an error in "Time Finished" which should read 11:45; however, the elapsed time is recorded correctly. The result of 1.8* fibers/cc is less than the OSHA maximum. This was a wet-weaving operation and the-dust pro bably came as much from the nearby creels as from the weaving itself. ' To check this, you may wish to take environmental samples at different places in this room. The recommended sampling time for a retest is 90 minutes.
Sample R-3. This sampling covered two operations: the drill press and the vertical sander. An oscillatind fan was blowing across the drill press towards the operator. This probably increased the test result measured on the operator. . An average of 3.7 fibers/cc was found for the combined operations. While meeting the present OSHA standard of 5 fibers/cc, some improvement is necessary to meet the 2 fibers/cc limit which is effective July i, 1976. The recommended sampling
SpecializingIn measuring airborne asbestos fibers by ike fitter method
Reddaw ay 00075
Mr. Vincent LaCarrubba
- 3 -
November 11, 1975
proper filters, are sealed with cellulose bands, and have been tested for
i
leaks. In another padcage I'm sending a rubber hose equipped with damps .
i
but without the adapter fitting. The fitting is not really essential since
the rubber tubing can be attached directly' to the monitor after the, red plug
l
is removed. If you want to use a fitting it can be purchasedfrom:
i
l
1 Aerosol Adapter XX62 000 0<l @ approximately $10
Millipore Corporation
I
Bedford, Massachusetts 01730
i
My invoice covering my services is endosed.
If you have any questions Vince, please call me and 1911 try to answer them for you.
Sincerely,
Ralph L. Lanz v
f'i 5 ;l I s I
j
Reddaw ay 00076
w
V
measurement of airborne asbestos fiber
Ralph L. Lanz SOCI Grant Avenue Philadelphia, PA 1911* Tel. <215) 637-7*32
Sample Mo..f i - J Date Sampled: / / /d A z S T
Ccwpanv/Plant/^^n/wV l 'r . f n . Department;t J e -- Equipment 0
LUJjL
Material Usedt/zr^-r-y
1 ^ 2-1*Z t.it Z .
Operator: d l ^ D y * P lA
____Jobs____ m / A -
Describe what operator did during sampling period:__
1 ^Respirator Used? A /
M2Eade: /> /`>hur& __
Type Sample: Personal: y/'
_Epviropnent4l: M /j --- S m p M by: f . f t C a t e t e A
Time Finished:
H .`J ?#L
Time Started:
/r> I/O
Elapsed Time, Min.
&
Pimp No * -
Rate, Liters/Min.
JL
Volume Sampled, Liters: / tL * i________
Remarks:
U lA k .u iL f j U U & Z L U jU L S.C
Total Fibers // Total Fields / d f t
Av. Fibers/Field
Fibers/oc ,9
Reddaw ay 00077
m e a s u r e m e n t or AIRBORNE a s b e s t o s f i b e r
Ralph L. Lans SOOl Grant Avenue
Philadelphia, PA 1911H Tel. (215) 637-7H32
Sample Ho. J. Date Sawpled:
jJsiZ
CoMDanv/Plnt:/Vn/^<.^
Lb&JkU"Department:
Equipment Used; / a
tTTz
.
. .,,
Material Used:4j^r/V ggflL-- , ________ Product Hade;
_________
Operator:
U JL L E lL>7~T Jobi
u /jt.
^Respirator Used?
Describe hat operator did during sampling period:^
Type Sample: Personal: J . _____ Environmental: d/// Saapled by:
Time Finished:
U L& .
Time Started: /o?jt.a_________
Elapsed Tine, Min. ft%__________
Pump Ho. -
3-
Rate, Liters/Min.
__________
Volume Sailed, Liters: /4
Remarks
a CleH PlMa.*iM<f.ir /ftP*_______________________
Slide Prepared: Date: ///f/nTBy:*
Fibers 5 Microns
t / A...
A
o0
/ 0
7 0
2 a
L i
J 1
0f Xo
2A. J
--
i / 2 /.
0 1
l6 2, o
2 7
A_.
a / i A2
I o - d % . A ..
c 0
o 2
Io , 7
t i
f 1
/
0v
- #
a, i A A I
/ / O| i
a o
j
/
/
AA 1
oi
1A
/ Jl
-JL- A
Total Fibers 26 Total Fields JQ
* Av. Fibers/Field e S k Flbere/cc 7. g
Reddaway 00078
HEASUW5MBNT QF AXRBORNE ASBESTO FIBER
Ralph L. Lanz 5001 Graat Avcnue
Philadelphia, PA ltllt Tel. (215) 637-7M2
^ '/ * rtc*
Sanple Ho./?-?_____ ______
"" -------Date Sanpled; // /<//?r
Coopaay/Flant :
>w f i r t . C a Pepartnent;^ ^ / ^ --- Equipweot Oaed
J
Material Used;
Product Hade:
Operatori
C Z Ai// a a, n_______ Job: /A ________ Reapirator Used?
______ !
Deacaribe what operator did duricg sampling periodi f i / S T
-fliP/LL rfp&SS * /_______
--- Sece>*Q U T M *>).-V /r/c*L S a ,, dc- - o cjn M Jtu L
l sJL
ad,
;
Ih J lJ ^ L J L tJ S iL L ^ Type Sanple: Personal; y/
Environoental:
Sanpled
Tia Finished; Tine Started:
/JVo /j_
.2___ ________ Rate, LIters/Min.
PunP * *
Reddaway 00079
v -
MEASUREHEHT OF AIRBORNE ASBESTOS FIBER
Ralph L. Lanz 5001 Grant Avenue Philadelphia, PA 191m Tel* (215) 637-7432
Sample Ho. .<?.t/ Pate gampled: / / /* //7 3 T
Company/Plant:/ ^ i M V / / ? y M fc . C g .`Department: ^/^//^ ^ J q u l p o e n t Uacd;^ , ^
Material Used:
L&A______ 1____________ ^Product Hade:
a / / ___________ 1
Operator:
$ oM tftJ
Job:
A j/r t
Respirator Used? A/<y
Describe what operator did during sampling period: ^ [Z u o
jvmnrkl
g m i>li ........ ...................................................................
Type Sample: Personal Time Finished:
Tine Started:
tl'A -%
Elapsed Time, Hin. .`foO'lv
Rcnarics:-f</<</<V^tittM/fitTy
Environmental:
Sampled b y : / A & / ! * u f i
Puny Ho. . Rate Liters/Hin
A ___________
Volume Sampled, Liters: /Jt /
V/t/Oatu^i.pP* i.rftaitnP*'!/,trrytiAU.iT06L& L
rantm
.. Slide Prepared: Date: / / / < ~ _ Slide Counted: Date: ////7<)ly Remarks:
Fibers 5 Microns
/
o
/
W
/ A * ...
o
o
o
/
o _c
..o
s
(> - / ' o t
\ f) /
0
.
r^v`v'r:*:^S3&:
0
2
e
J[
OO
o0
e
O
/
oa
0 07
/
o
o *
--0 _ o
o
t
A
0
00
/
o/0
O
Q .0
t
r ..
7
4-
O
/6
t
o' A
*
o
fO
7
0
o
,,ft. ,.g._ _j L _
o'
Fibers 5 Microns
Total Fibers V / Total Fields / a *
Av . Fibera/Field , V / Fibers/co /.'i,
Reddaw ay 00080
measurement of airborne asbestos fiber
lalph L. Lanz `>001 Grant Avenue hiladelphia, PA 1911* *el. (215) 637-7U32
Swple
Date Sampled: / / / y/ tJT
Company/?lant:fft) b tWAV* H tfr.C o ,pepart^nt:^ ^ t / z ^ ^ E qulpineDt Used
iaterial Usedy ^ <raty**_______________ Product Made: a//A ____________
IperaWs / V / z c w r / E
ixkJLkjUL & L f l ^ V A S , Respirator Used? V d
Oescribe what operator did during sampling period: a/ o j l M A L - /-/a/ .T '*> a s O
QFi:AArr>*ij L kL i*L ltiJL jA
QJZ3 u m 8 o
I qq/a .
type Sample: Personal:__ Z _______ Environmental:-------- Sampled by;V
rime Finished:
Pump No. .
____ _
\ time Started:
Rate, Liters/Min.
jz
Elapsed Time Min. S o '/z i.
Volume Saapled, Liters: / b )
R*aric3:fa r * MjU X JL U ^Ju^
^ _ Slide Prepared: Bate: J t l s 'h t~By
Remarks:
///7/7r Slide Counted: Pate: //A/ta'Bv :
Fibers 5 Microns
Fibers S Microns
2 2 2 J o,,
_/_ Y /
(
./
2
o
/ a o . -1
i t / - . X _
i
2 ,1 .2 - 3
1
/ 1r / / t
2 t _o 1 A
JY
l X.
.. 1 o 2. 1 &
AD1f a
./ i / *
_7 % 1 . 0 o
a. j 4 A A
./ A A 7
_7 o 2 1 X
_3 / 2 /
& dT 2 A .A
o
& A A a.
-1_
-ft- A a-
Total Fibers // Total Fields / c o
Av. Fibers/Field A V/ Fibers/oc V, ?
Reddaway 00081
MEASUREMENT OF AIRBORNE ASBESTOS FIBER
alph L. Lanz 001 Grant Avenue hiladelphia, PA 19114 el. (215) 637-7432
oinpany/Plant:S et}/) nu.aV
Sample Ho.
>7
Date Sampled:
_ _ ^ ^ t a e n t : --- Equipment Oaedz/^^^
taterial Used:yO</argx
3o
2-
Jfcoduct Hade:
Operator: f j . c m e~a jC A~ # o i ~ A U ----
iC jk .
tescribe what operator did during sailing period:
/ J U it S z Used 0 & /LaoM
Q M M jlUJL_. _______________
Reddaway 00082
L LANZ
! 1
on Cfshaloi
S001 Grant Avenue
Philadelphia, PA 1911h
Tel. (215) 637-7432
I
May 3, 1976
Mr. Vincent LaCarrubba Reddaway Manufacturing Co. 32 Euclid Avenue Newark, N. J.
Dear Vince,
This report covers tests carried out on the four samples of airborne
asbestos dust which you sent to me recently.
I
The analyses were carried out using the procedures of the U. S. Public
;
Health Service. The fibers over 5 microns per field were determined and the
j
fibers over 5 microns per cc were calculated from this value and the data you ?
submitted for sampling time and rate.
You also asked for an analysis of particles less than 5 microns. On examination of the samples, it proved to be impractical to count all particles under 5 microns; -instead, all particles which could be classified as fibers ( i. e.* having a length/diameter ratio of 3 or more) were counted.
The results are. shewn in the following table:
Sample No.
RE-7
RE-8
RE-9
RE-10
i
Sampling time, min.
V iT
120
105
480
Rate, liters/min.
2
2
2
2
Volume sampled, liters
290
240
210
960
Fibers over 5 microns:
Fibers/field
0.48
0.67
1.20
0.13
Fibers/cc
0.57
0.95
2.0
0.046
Total fibers :
Fibers/field
1.6%
2.12
3.66
0.42
Fibers/cc
1.9
3.0
6.0
0.20
% of total fibers over
5 microns
29 .
32
33
23
None of the samples gave results which exceeded the new OSHA limit of 2 fibers over 5 microns per cc which is effective July 1, 1976. However, sample RE-9 was right on the limit.
I*ve shown the per cent of total fibers which are longer than 5 microns
I
and this value seems to be about 30%. There were insufficient fibers counted for
sanple RE-10 for the percentage figure to be representative. The value for per
j
cent of total fibers over 5 microns may be important in future tests to indicate
if your new equipment is more effective in removing longer or shorter fibers.
Specializingin measuring abrame asiesiosfliers ig thementirme fillermelho} Reddaway 00083
- Z -
n ay a, 1376
Enclosed are the completed data sheets which you sent with the samples* Also enclosed is my invoice covering these tests*
If you have any questions Vince, please give me a call*
enc*
Reddaway 00084
if
id?.
i-.V'\ f`:V
MEASUREKENT OP AIRBORNE ASBESTOS FIBER
Ralph L. Lane. S001 Grant Avenue
Philadelphia, PA 19114 Tel. (215) 637-7432
Sample No Date Sampled:
Cowaanv/Plant:/ V AL/A \ f H f6 ,C o . Dpartant^ / j y / ^ ^ ^ Equip^ent Used
A *eruT M*t*rlal UMdi^^Sui
Product
'J&
J S Tf kU t
tU
OperatoriC Jt^Jk d it____ Job. A //k _____
Respirator Used?
Describe what operator did during saaplisg period:a/ oLM AL J w jucTS***-!
type Sample: Personal: Tim Finished:AAl. Afe JH LTim Started: .. Elapsed. Tim, Hin. Bcearks:)Ue%TUeiu\
Environnental: y/' Saapled b y ; J CJLa Ca A
Pump Mo. Rate, Liters/Min.
J L _____________ j
Volume Sanpled, Liters: d 9 A
4 * 7 t~*** eiDS> . */*
- JktA E Z L
Slide Prepared: Date: V Al fer Re>iarkB;M friu a Y -.i9io,x-n/
fti.sr /feAtt fcgAa,
Fibers 5 Microns
0 / 4SI A 1 /
fi 1 45 fi
A. f _ fi c
gfi
fi %
1 fi
fi fi - fi , I SU
fi fi fi . f
fi. 0 f fi t
// fi _o
0 fi
6 fi
f i
- 1
.
(0
fi ai.-
fi. o fi / _ A .
fi f fi fi o
A
1/ f
o _fi fi _ f i t 1 i" o
#?
a. I fi- 1 fi
. fi - 1 fi- fi
fi 0 fi / fi
3L fi fi
-J_ -JL. fi / fi
e*0 TotalMFiAbers^ - Total Fields /flfl, lit-
Fibers s Microns
/ z fi 2 X i fi X fi 1 .O- .--fi i
fi a 1 7 fi .fi_ 1 3 a t fi A
\ A- ' 1 A a
2. fi / / 4 fi fi i
2 /-
fi A.
fi /
0
3 y
2y
a
JU fi
h? L ? - A , -JL-
fi I 1a 1
A . fi
A fi 2
f - JL-
fi fi 1
J-- 9 1
A H " j--
1*
fi, 2
V
y
1
_ts--
z
i t
z
At. Fibers/Field y > n bers/oo
: ;a
1
1 ! -
Reddaway 00085
MEASUREMENT OF AIRBORNE ASBESTOS FIBER
Ralph L. Lanx
SObl Grant Avenue.
Philadelphia, FA 1911! Tel* (2IS) 637-7432
Sam ple Vo.
-R
Date Sampled:
Coepany/Plant;SfMi u r f ttf<r ^Department'.(JfAviA/C. Equipment Vaed:A mJA,L&i
Material Used
-_UL^l_________________ Pmdtiet Hades
Operator: 6 />60/j Vt/hC/cs/_____ A/J&--------------- Respirator Used
Pescribe What operator did during sampling periods a/oL*iaL /*&A/C7 /**/*&
type Sample: Pereonal:
Environmental:
Sanpled by:) ^ L a (?a A4A .
time Finished: P.M- J '-hO Time Started:ff /J:3d________ _
Pump Ho. Rate. Liters/Hin.
J _____________ 2_____________
Elapsed Tine, Mia, / i d ________
Volume Sampled, Liters:
___________
Jd/ffzt4.A f z.7t------------- ----------------------------
Total Fibers L 1? Total Fields^ > / d d
dead
u m m /ifS
/Field 2 Fibers/ce
/.V^
.9 5 *
w
Reddaway 00086
MEASUREMENT OT AIRBORNE ASBESTOS FIBER
Ralph L. Lana S001 Grant Avenue Philadelphia, PA 1911 Tel. (21S) 637-7*432
Sstaple No ^ 9 Date Sanpled:_ liA s A i
Company/Plant; ^ ^ o a n t u ^ y
AHHrex 7" Material U s e d : ^ ^ ^
C l ttC tu PcP*tt*c"t:
_ .
, ..
^
Produet Hade? AA,+}
Operator:
itd/^okJ-Jobl-- < 4 ^
Respirator Used?
Describe what operator did during sampling period: /|^ ^
EiM^ l>c>>t
type Sample: Personal: Time Finished4 ^. //.V.T tTime Started:4</f. /a; Elapsed Time, Kin, tQ tC Rgmax*g:l6 jj! L j& L - J L z I L
1Slide Prepared: Date: 1Remarks: A ir-D i u +i
Sailed to r-J & jA & J tM /S a
Fuap Mo.
__1___
Rate, Liters/Kin.
Volume Sampled, Liters: J / i
Slide <**** Date:1
BMOMjiXL-CUL.
f/*'L L f.< L .t .
I..-...VVnKW
a-V: 5
** HS*`I
i9G~s pc..
v
/d'd
*V4>
v*/
3
Reddaw ay 00087
, MEASUREMENT OFj a i r b o r n e a s b e s t o s FIBER
RSa0l0p1hGrL.antLaAnvaenue H
Philadelphia, PA 19114 Tel', (215) 637-7432
Sample No. Date Sampled:
c o ^ v /tu -a i-.jB e e e a ii jL
&
Equipment Used: a/ A
Material Used: -M .-- ------------
Product Made: A /f / 4
_\ ______
v / .
Job: * //& .
.Respirator Used? a/ / A
Describe what operator did during sampling period:,.
Type Sample: Personal:.
Tine Finished:P*H
ito
>! Tine Started:
tf
Elapsed Tine, Min,
Environmental:
Sampled by:
Mo.
A
Rate Liters/Min
Volume Saapled, Liter: f Z o
L
/
A a
jn
A 0
O 0
-00 --0 0
-X-
'ibers> 5 Microns
a
0 .
do06
0
0
o
/
1 ft 0 0
1
0
Q
o
0
0
J
0
o
0
p0
- 0
0
O
*>'
0
0
> o
P
e>
ft f
Of
0
o
O
0
l 0
-4 >
0
0 6
JL1
0 o
p 0 0 CL P
-L-
P0
_0_ 0
o
\
00
o0
o0
0
.0._ 0
0 -J2L.
Total Fibers A3 Total Fields^
fct-3 tSIp!
%JL VX
/C
Mic.ie 4
Av. Flbera/Flsld AS Flbera/oc ^ S ^ . e
w Reddaway 00088
A
James F. McVeigh Industrial Hygiene Laboratory Services Manager
American C an Com pany
Safety & Industrial Hygiene Laboratory A IH A Accreditation No. 29 H EW /CO C License No. 29 1052 U.S. Highway 22 Union. N J. 07083 201-686-4500
August 1, 1978
Mr. V. LaCarrubba Reddway Manufacturing Co., 32 Euclid Avenue Newark, New Jersey 07105
Inc.
Pear Mr. LaCarrubba:
Fiber counts for eight asbestos filter samples are as follows:
TABLE 1
W
Sample No.
Fibers/Cubic Centimeter
R-18 R-19
M /A te)N
R~20 C A & L f/u z/t Q k 'ifo ffe o R--21 eH B o >H R-22
* y
R-23 R-25 R--26
, L M M * *4
ftfijE H W
1.46 0.77
2.6 0.54 0.67 0.44 0.87 0.87
TH C ST Z t/L T M O > tC A T 2 > t
T ite l/
Note:
ir
>f!
Fibers were counted in accordance with 0SHA standard for asbestos using a B/L Phase Contrast Microscope.
Very truly yours
JFM:clc Attachments
Manager Lene Laboratory Services Ifety & Industrial Hygiene /i.H. No. 776
Reddaw ay 00094
James
F.M c V e ig h
Industrial Hygiene Laboratory Services Manager
American Can Company
Safety & Industrial Hygiene Laboratory A IH A Accreditation No. 29 H E W /C D C License No. 29 1052 U.S. Highway 22 Union, N J . 07083 201 -6 8 6 -4 5 0 0
September 5, 1978
Mr. V. LaCarrubba, Technical Director Reddaway Manufacturing Co. i Inc. 32 Euclid Avenue Newark, New Jersey 07105
Dear Mr. Carrubba:
Samples picked up by the writer August 31, 1978 were analyzed in accordance with NIOSH's counting method for asbestos type fibers. Results are indicated in the following Table I.
TABLE I Reddaway Manufacturing Co., Inc. - Sept. 1, 1978
Sample No.
R-30 #1 R-30 #2 R-30 #3 R-30 #4 R-30 #5 R-30 #6
Volume of Air Sampled Liters 120 120 200 120 150 100
Fibers Counted Per Cubic Centimeter
3.79 2.68 2.1 2.37 1.89 2.19
Please advise if you have any questions. Very truly yours;
JFM:dc Attachments (6)
McVeigh, Manager iustrial Hygiene Lab Services
& Industrial Hygiene >X.H. No. 776
Reddaway 00096
. i
A
$* l
*
I
-i
I
1
i
American C an Company
i
James F. M cVeigh Industrial Hygiene Laboratory Services Manager
Safety & Industrial Hygiene Laboratory A IH A Accreditation No. 29 H E W /C O C License No. 29 1052 U.S. Highway 22 Union, N.J. 07083 201-686-4500
September 19, 1978
Mr. V. LaCarrubba
Reddway Manufacturing Co., Inc. 32 Euclid Avenue
Newark, New Jersey 07105
i
Dear Mr. LaCarrubba:
I
Fiber counts for the eight (8) asbestos samples submitted to our laboratory on September 18, 1978 are as follows:
Sample No.
Fibers/Cubic Centimeter
R-33 blank
--
|
R-33 #1
1.82
R-33 #2
2.13
]
R-33 #3
2.7
5
R-33 #4
1.96
R-33 #5
-
1.71
R-33 #6
1.03
R-33 #7
0.99
These samples were analyzed on September IS, 1978 following the NIOSH recommended procedure. Fibers were counted In accordance with the OSHA asbestos standard using a B/L phase contrast microscope.
Very truly
JFM:dc Attachments
(m p f l
James F. McVeigh, Manager Industrial Hygiene Lab Services Safety & Industrial Hygiene C.I.H. No. 776
Reddaway 00095
A
American Can Company
James F. McVeigh Industrial Hygiene Laboratory Services Manager
Safety & industrial Hygiene Laboratory A lH A Accreditation No. 29 H E W /C D C License No. 29 1052 U.S. Highway 22 Union N J . 07083 201-686-4600
September 12, 1978
Mr. V. LaCarrubba, Technical Director Reddavay Manufacturing Company, Inc. 32 Euclid Avenue Newark, New Jersey 07105
Dear Mr. LaCarrubba:
Analytical findings of seven (7) filter samples are listed In the
?
following Table I, for asbestos fibers* Please advise if you have any
j
I
questions.
A '3 /
Sample Number
TABLE I
Volume of Air Sampled/Llters
Fibers Counted Per Cubic Centimeter
of Air Sampled
6A & X
F fU S /L M
M /f
l
j
JttZ tJLT S M & > & r7 % >
*3/
1
A -it 2 A-31 3 A~st 4 A 'H 5 A-it 6
4-*/ 7
120
120
90
120
120
'
150
120
i.o 0.48 1.82 0.83 2.39' 0.82 2.76
Note: Samples were analyzed in accordance with NIOSH METHOD No. P & CAM 239.
A ! FCJL
J A tO
'jitftH
i
Very truly yours,
JFM:rm
P. McVeigh, Manager tdustrial Hygiene Lab Services Safety & Industrial Hygiene rC.I.H. No. 776
Reddaw ay 00097
American Can Company
James F. McVeigh Industrial Hygiene Laboratory Services Manager
Safety & Industrial Hygiene Laboratory A IH A Accreditation No. 29 HEW /CDC License No. 29 1052 U.S. Highway 22 Union, N J . 07083 201-686-4S00
Mr. V. LaCarrubba Technical Director Reddaway Manufacturing Company 32 Euclid Avenue Newark New Jersey 07105
Inc.
August 8, 1978
Dear Sir:
*
Seven filter samples were analyzed on 8/8/78 by the writer for asbestos fiber in accordance with the OSEA code and the following results were noted:
V
Sample No.
Fibers/100 Fields
Fibrs/cc
R-27-1
52
1.48
R-27-2 R-27-3
77
2.31
60
2.28
R-27-4 R-27-5 R-27-6 R-27-7
42
1.31
// 2
39
1.11
61
1.74
53
1.21
T H 7'
Very truly yours,
x/
J F M :rm
iger idustrial Hygidbe Lab Services Safety & Industrial Hygiene P C.I.H. No. 776
I
Reddaway 00098
4k
i I:
American Can Company
James F. McVeigh Industrial Hygiene Laboratory Services Manager
Safety & Industrial Hygiene Laboratory A 1H A Accreditation No. 29 H E W /C D C License No. 29 1052 U.S. Highway 22 Union, N J . 07083 201-686-4500
November 27, 1978 : V'
Hr. V. LaCarrubba, Project Chemist Reddaway Manufacturing Company, Inc. 32 Euclid Avenue Newark, New Jersey 07105
Dear Mr. LaCarrubba:
Please note our laboratory findings for asbestos fibers in the attached Table I.
Your twelve (12) filter samples were processed in accord
1 1
ance with the NI0SH Analytical Method No. P & CAM 239. If you
have any questions, please advise.
l
Very truly yours,
W
i)
Jambs F. McVeigh, Manager
Safety & Industrial Hygiene
C.I.H. No. 776
JFMrrm
Attach.
Reddaw ay 00099
t: f. %
* ** *t
*
*
r
TABLE I Asbestos Fiber Count - Fibers/Cubic Centimeter
Reddaway Manufacturing Company. Inc:_____
Sample No. R-34-1 R-34-2 R-34-3 R-34-4 R-34-5 R-34-6
Volume of Air Sampled/Liters
170 118 174 116 118 182
Fibers/cc (1) 2.91 ^ 2.34 2.73 1.94 1.54 " 1.84 ^
R-35-1
158
1.36
V R-35-2 90 0.95
R-35-3
174
1.42
R-35-4
116
1.0
R-35-5
118
1.25
R-35-6
182
1.71
(1) Fibers per cubic centimeters of air sampled.
h. ' ,
" jf ` . * \*
Reddaway 00100