Document oD7rypbzr9pK9ne55bgQ5aELg
Monsanto %
PaulFROM I NAME * LOCATION* B. Hodges - E1SF General Offices
April 28, 1972
--ct
RLFERENCE
PCB's - ALLOWABLE DISCHARGE ^ROM PRODUCING/PSINQ PLAMTS
TO J. R. Savage W. R. Corey
F. J. Holzapfel
W. R. Richard
E. S. Tucker
D. B. Hosmer
R. J. ICozacka
W. B. Papageorge
P. S. Park
K. W. Easley - Washington D.C.
G. L. Bratsch - WGK
A. E. Leisy/R. M. McCutchan
R. M. Blowers - WOK
P. E. Heisler/C. F. Buckley
0. A. Hippe - WOK
*W. C. Engman/E. E. Stewart - WOK
STLCOPCB4070821
-1-
PCB's - ALLOWABLE DISCHARGE PROM PRODUC INQ/USING PLANTS
4/28/72
MINUTES OF MEETING - 4/13/T2 IN EPA OFFICES, WASHINGTON, D. C.
A, Present
For Monsanto
K. Warren Easley - Washington Office
W. B.Papageorge - G.O.
A. E.Leisy -
WOK
R. M. Blowers - WOK
W. C.Engman - WOK
E. Scott Tucker - MIC - Research S. 2nd.
P. B. Hodges -
Q.O.
For EPA
John L. Buckley - Deputy Director - Ofc. of Research
Alphonse F. Forziati-Chief, Measurements & Instrumentation
Branch
Paul E. Des Rosiers-Staff Engineer, Industrial Pollution
Control
Elizabeth Anderson-Staff Chemist - Ofc. of Tech. Analysis
Gordon Everett - Director - Ofc. of Tech. Analysis
Marilee Miller - No title
Olenn Pratt -
Chicago Region Enforcement
Kathleen Schirmer- Staff Ass't. (New Toxic Dlv. not established)
B. Background of Meeting
The Task Force for PCB's, with representatives from various
Federal agencies Including FDA, EPA, USDA and coordinated through
the Office of Science and Technology, will soon release its
voluminous report on the PCB's problem. Monsanto has cooperated '
with the involved agencies and had some insight into what would
appear in the report. We agreed generally with nearly all of
the report recommendations, but could not concur with two recom
mendations (as we understood them):
0S\N 310836
STLCOPCB4070822
-2-
(1) Water quality standard for PCB's to be set at 0.01 ppb for rivers and lakes.
(2) Zero detectable level In discharges from plants producing or using PCB's. An Inconsistency existed In that we understood that the 0.01 ppb water quality standard was derived from a calculation involving 10-year low flows In the Mississippi River and a 3 lbs/day discharge from our WOK Plant (their understanding of what we were discharging to the river - the 3 lbs/day is equivalent to about 0.01 ppb in the river with no allowance for background).
A meeting was requested to discuss these recommendations with Dr. Buckley, with intent to prepare a formal presentation for them. However, due to time pressures in EPA, the meeting was set up on 1 day's notice. Our information and comments had, therefore, to be presented informally, with little time for preparation. The Monsanto group met to plan for the meeting on Wednesday afternoon, the various assignments/presentations were prepared that night and were reviewed on the plane to Washington, followed by another quick review in Warren Easley's office.
Our objectives for the meeting were: (1) To induce EPA to recommend a more realistic water
quality standard than the 0.01 ppb - say, 0.1 ppb. The higher level would be more in the range of reasonable precision by the average laboratory and would recognize a small PCB background.
DSW 3^
STLCOPCB4070823
-3-
(2) To Induce EPA to drop the "zero discharge" concept and to allow a reasonable discharge (5 lbs/d ay) In terms of lbs per day - not concentration. 5 lbs/day Is conslstent with requests of the electrical Industry using PCB's.
(3) To Induce EPA to allow a reasonable time to attain the discharge limit.
C. Minutes of Meeting (1) Following "round-robIn" Introductions, W, Papageorge stated our appreciation of this first opportunity to discuss with them the problems Involved with plant discharges. He stated our desired format, which was to have various plant people discuss what we had done and were doing to control FOB discharges and to explain the problems Involved. Buckley concurred. (2) Art Leisy spoke briefly of the complex nature of the WOK Plant, the relationship to Sauget Village and the concern within manufacturing of the environmental Impact of wastes from the manufacturing processes. (3) Dick Blowers discussed physical growth of the plant, complexity of the sewer system, size and extent of our current program for ln-plant waste reduction and control. He pointed out that PCB's were a major one of numerous concerns where we were actively planning recycling or otherwise reducing wastes. He did not discuss the type of waste treatment Sauget Village Is contemplating. Some remarks from Glenn Pratt and others about secondary biological treatment were Ignored.
DSW 310838
STLCOPCB4070824
-4-
(4)
Bill
/
Eng. man described
the
PCB
containment
and
in-plant reduction program (full text is attached).
.
At the close of his talk, he stated the present level
of discharge as follows:
(a) From PCB manufacturing facilities - 2 to
4 lbs/day.
(b) From the Village waste treatment plant,
5-10 lbs/day.
(5) Dr. Buckley went through his rationale for the
proposed limits:
(a) PCB in water is toxic to fish at very low levels -
under 1 ppb for some species.
(b) They know from experience that PCB levels magnify
greatly from water to fish - he said 75000X.
With that factor and a FDA allowable limit of
5 ppm, allowable PCB concentration in water
would be:
.
5 ppm 75OOO
- 0.07 ppb (approx.)
With using a safety factor (7), this brought
the allowable water level to 0.01 ppb. Buckley
stated his Intent that the 0.01 ppb level not
be imposed as a legal standard but be used aB
a working limit.
(c) As a check on the reasonableness of that level,
he had calculated the effects of our discharge
of 3#/day (their figure) on the Mississippi
River at 10 year low flow of 50,000 cu ft/see.
DSW 310839
STLCOPCB4070825
-5-
That also equals 0.01 ppb at the low flow (or about 1/3 of that at average flow of 175*000 cu ft/sec which would allow an additional safety factor). (d) They (EPA) have no actual measurements of PCB levels In the Mississippi south of LaCrosse, Vis. and don't plan to do any water measurement work. Buckley appeared disappointed that we have no actual background level measurements in the Miss issippi River. They will plan to do monitoring by fish concentration studies - If fish PCB con centrat ions are under 0.75 ppm, the ambient water Is likely to be under 0.01 ppb. (6) As to allowable discharge, Buckley said they were con sidering a policy of zero "knowing discharge" (a term new to us and meaning any discharge above the absolute back ground level). This would appear to allow continuation of our background discharge plus a minimum amount from production facilities. He said that, where we were presently down to 2-4 lbs/day from our production unit, we could probably do more work and get to 1-2 lbs/day and that (plus our background) would be our "zero knowing ~ discharge". (Note, In a later telephone conversation with Bill Papageorge, Buckley confirmed the above and said he planned to circulate a private memo within EPA explaining what "knowing" and "non-knowing" discharges meant and that our present discharge from production facilities of 2-4 lbs/day appeared reasonable).
DSW 310840
STLCOPCB4070826
-6-
(7) Scott Tucker questioned ability to measure at the 0.01 ppb level. Dr. Forzlati stated that their Athens, 0a. and Cincinnati, Ohio Analytical Labs are capable of easily detecting 0.01 ppb of FCB's In environmental samples, but they would not feel confident enough In their numbers to attempt enforcement at this low of a level. Re went on to state that, "they would be confident enough at the 0.1 ppb level to go to court." When presented with the results of our Internal round robin study (PCB method accuracy and precision) at a level approximately 50 thousand times higher than the proposed 0.01 ppb number, he again stated their labs were achieving better results. He also Indicated that they were making quantitative PCB measurements via mass spectography at the nanogram level.
(Notes from Scott Tucker - "Based upon our lab experience, I would say that Dr. Forzlati Is a little overly opti mistic with regard to the accuracy and precision of current PCB methodology. Dr. Forzlati extended an invi tation to Monsanto to.visit their facilities and It Is currently planned to contact him and arrange a visit. The objective of the visit will be to get a better feeling for their PCB analytical capabilities and to " establish direct contacts with their analytical people"). (8) Paul Hodges raised the question of mixing zones. Dr. Buckley had stated that full flow In the river was used in calculating dilutions In the river because there was no acute toxicity problem with fish around the outfall.
DSW 310841
STLCOPCB4070827
-7-
Hodges pointed out that, when the Federal report is re leased, the states will move to enact PCB water quality standards and discharge regulations. Some of them, specifically Illinois, use limited mixing zones to determine compliance with water quality standards (in Illinois the sample is taken 600 feet downstream from the outfall). Hodges requested that the Federal report spell out the principle of using full dilution in the river. Buckley agreed. (9) As an aside after the meeting, Glenn Pratt (Surveillance, Chicago Regional EPA office) said that they were concerned about the levels of mercury being reported to Illinois since they were over 0.25#/day. He said he had written a letter saying they wanted to come to see us about mercury and about PCB's but had not sent the letter when the sub ject meeting was arranged. He would be contacting us in 2-3 weeks. Art Lelsy had, earlier in the meeting, in vited Pratt to inspect our PCB production unit and con trol facilities. D. Summary and Conclusions (1) We feel that Dr. Buckley is taking a reasonably realistic approach to control with his "knowing" and "non-knowing" - discharge concept. However, we are dubious that:
(a) It will hold up as the document is reviewed within higher levels and other branches of EPA.
(b) The Illinois Pollution Control Board will be as understanding as is Buckley when they move to formulate water quality standards and discharge
DSW 310842
STLCOPCB4070828
-8-
regulations for FCB's. We would expect the Board to wove shortly after publication of the Federal Task Force document and announcement of standards and regulations by the Federal EPA (2) The 0.01 ppb water quality limitation is likely to hold up even though measurements at this level are not accurate and the Federal people have very limited data on PCB concentrations In rivers and lakes. It Is also likely to become or to be used as a legal standard. (3) Apparently, Buckley moved quickly in his calculations establishing the 0.01 ppb limitation from the FDA level of 5 ppm In edible portions of fish to magnification of 75000X from water to lipid portions of fish (see C-5 above). This provides an additional safety factor to the 7X In his calculations. This was not really challenged at the meeting. (4) We don't know whether or not 0.01 ppb Is exceeded either above or below our outfall In the Mississippi River. We have analyzed two large adult Mississippi River carp for PCB's. They contained apparent PCB concentrations of 1.4 ppm and 5.1 calculated on the whole fish basis. Using Dr. Buckley's concentration factor of 75*000 Indicates that the river could contain 0.02 - 0.07 ppb ' at the point where these fish were collected (this assumes that the 75,000 factor could apply to whole fish - we are uncertain about this). Further flsh/Water monitoring Is needed.
Paul B. Hodges
/ms
DSW 310843
STLCOPCB4070829