Document oD7LX1e9VRGGmd86DZa4eE4g
Worksheet
HAZOP-PC 1.00
Company: DOW CHEMICAL CO. Process: HDPE - POLY B
Node: 3 Page: 1
H----------_____________________---------__________-----______--_____------_____--------
Node: 3 Discharge Line from DR-2007 to DR-2008
Parameter: Flow +---------------------
Intention: Transfer Powder
|GUIDEWORD DEVIATION! POSSIBLE causes
CONSEQUENCES
RECOMMENDATIONS
BY |
No
No Flow Rotary feeder
Overload DR-2007 Evaluate
GH
trips.
Plug E--2302
max.purge flow.
Too high purge. High press.in
Break rotary
DR-2007
Evaluate rotary KW
feeder.
valve tripping
Fused polymer.
the feed.
More
More Flow None
None
AsWellAs AsWellAs Reverse flow
Water in the dry
Flow
through RF-2008. recycle solvent.
Evaluate vent to GH flare with filter
Reverse Reverse Flow
+--------------- +--------------- +----------------------------- +------------------------------- +----------------------------- +---- +
00 A 120948 CONFIDENTIAL
Worksheet
HAZOP-PC 1.00
Company: DOW CHEMICAL CO. Process: HDPE - POLY B
Node: 3 Page: 2
^--------------------- ------------------------------------------------------------------------ ------------------------------------------------------------------------------------t-
Node: 3 Discharge Line from DR-2007 to DR-2008
Parameter: Temperature
Intention: Assure Dry Powder
+------------------ +------------------ +----------------------------------- +------------------------------------- +----------------------------- +---- +
GUIDEWORD DEVIATION POSSIBLE CAUSES
CONSEQUENCES
RECOMMENDATIONS BY |
More Less
Higher Temp
Lower Temp
Rotary feeder clearance. Upstream temperature failure.
Failure of temp.control. Build up on wall and loss of heat transfer. E-2302 plugged. Too much cold feed.
Fuse polymer. Plug line. See no flow.
HAZOP temperature control and DR-2007.
Solvent wet polymer. Overload continuator. Emission problems.
HAZOP DR-2007.
Evaluate location of temperature element in line.
*
* GH
DO A 120949 CONFIDENTIAL
Worksheet,
HAZOP-PC 1.00
Company: DOW CHEMICAL CO. Process: HDPE - POLY B
Node: 3 Page: 3
H _--___-------------------------------- ----______ --
_____ ____________ ___
----------------------- h
Node: 3 Discharge Line from DR-2007 to DR-2008
Parameter: Pressure
Intention: Less than 1 psig
-)------_____--i-------------------i--__________--------- --+--------____________--i----------______--
|GUIDEWORD|DEVIATION| POSSIBLE CAUSES I
CONSEQUENCES
| RECOMMENDATIONS |BY |
+--------------------+-------------------- +---------------------------------------+-----------------------------------------+--------------------------------------- +------+
More
Higher
DR-2007
Rotary valves leak Alarm high
KW
Pressure overpressure and Increase
pressure.
vent line plugs. isopentane load on
continuator.
Solvent wet
powder.
+--------------+-------------- +--------------------------- +---------------------------- +--------------------------- +---- +
120950 00 A qENTIMCONF"1
Worksheet
HAZOP-PC 1.00
Company: DOW CHEMICAL CO. Process: HDPE - POLY B
Node: 3 Page: 4
+---------------------------------------------------------- --------------___________-----------______-------------------------------- -------I-
Node: 3 Discharge Line from DR-2007 to DR-2008
Parameter: Composition
Intention: Normal Product Ml/Density
+------------
|GUIDEWORD DEVIATION POSSIBLE CAUSES
CONSEQUENCES
RECOMMENDATIONS
BY |
OtherThan OtherThan Emergency
Fused polymer.
Write proper
RF
Comp
shutdown.
operating
Loss of reactor
procedures.
control.
Determine MI and RF
density
limitations of
dryer.
+------------------ +------------------ +----------------------------------- +------------------------------------- +----------------------------------- +----- +
DO A 120951 CONFIDENTIAL