Document oD4V090x7wXkJvDd3DeBYZXME
ETHYL CORPORATION
INTEROFFICE
To T. R. Robinson, M. D.
Address BR Plant
From H. M. Taylor
Subject Welding Fume in Maintenance Shops Baton Rouge Plant Preliminary Industrial Hygiene Report
Address BR Tower Date September 21, 1973
While conducting the recent asbestos survey within the Baton Rouge plant, I was also requested to perform a preliminary industrial hygiene evaluation of ventilation in several maintenance shops. Plant super vision indicated there had been some employee concern about ventilation control of welding fume.
Please keep in mind that this was intended to be a preliminary survey, as such it is not necessarily complete. I'll be glad to discuss any questions concerning the evaluation. If a detailed industrial hygiene ventilation evaluation is desired or assistance to evaluate fan performance or noise from these systems, please let me know.
HT :ws
cc: W. C. Strader S. D`Amend H. G. Borque R. Conrad J. Klock W. E. Rinehart, Sc. D.
H. Taylor
F-06909 ETC 00120
-4
F-06910
PRELIMINARY PrPORT OF INDUSTRIAL HYGIENE SURVEY OF MAINTENANCE SHOP WELDING FUME VENTILATION BATON ROUGE PLANT
Survey Conducted July 27, 1973 by
Henry M. Taylor, Jr., MPH Certified in Comprehensive Industrial Hygiene Practice
Ethyl Corporation Medical Department
451 Florida St. Baton Rouge, Louisiana 70801
c
REPORT FORMAT
Summary 1
Method and Rationale 1
Maintenance Shops; Impressions Sodium 2 Central Shop and R&D Shop 3
Maintenance Shops, Recommendations
Sodium______
3
C
Page
(
ETC 00123
^-069]?
SUMMARY
1
1. When an industrial hygiene survey looking for potential health problems
is made of a production facility, the initial approach is to look for
adverse effects generally attributed to the chemical and physical agents
used in the process observed. However, there has been a changing view
of what constitutes an adverse effect and now concern has been directed
to characterizing an irritating, stressful or otherwise uncomfortable
work environment.
2. Although a complete indepth study was not made of environmental contami
nants, there was no indication that a significant acute environmental
health hazard was present at any of the locations visited.
3. There was no evidence of chronic environmental health hazard conditions.
However, there was indication welding fume can accumulate in excess of
. t . .. _ .. j, ujn ^cdiiuciruS
ill
the liurth end of
the sodium maintance
shop on
an
inler-
mittant basis.
Method and Rationale
Visible "smoke" was produced by forcing aspirated environmental air
through a tube of stannic tetra-chloride. The artificial smoke was
released in the shop areas of concern to stimulate welding fume. The
observed effect of air movement upon this smoke was used as a guideline
to form impressions regarding particular welding fume control situations.
After some experience, this method of ventilation evaluation provides
a quick assessment of ventilation system performance. Often one can
quickly determine where more exact data is required. In addition, such
a demonstration provides a visable show for the doubtful that an effective
system is effective, in spite of an occasional odor. In other situations,
where fume control is obviously needed, further in depth evaluation often
ETC 00124
F-06913
2
does not provide information not already general knowledge. Maintenance Shops
Sodium This welding shop occupies the .arge open bay-type area on the
second floor of the sodium maintenance shop. There are three, six bladed, window fan type air exhausters located in the wall at one end of the welding shop area. The main outside air supply to the building was found to enter the building by a large door way located on the first floor below the three exhausters. Impressions 1. During the time of the industrial hygiene contact it was demonstrated the fume contaminated air from the second floor wall welding fume ex hausters was returned into the building through the large first floor doorway mentioned previously. After entering the doorway, approximately
the contaminated welding fume air passed to the second rioor through a large opening located immediately inside the doorway. It then passed above one of the welders to again cycle through the wall exhausters. One consequence of using this ventilation system with continous welding production is that the "short cycled" fan air becomes more and more concentrated with welding fume while at the same time it becomes less fresh. 2. Most of the remaining 2/3 of the incoming air which entered the first floor doorway moved across the lower floor and up a stairway opening located at the end of the welding bay opposite and away from the second floor air exhausters. Most of this air, at the end away from the wall exhausters, moved further away because it was demonstrated this air leaves the area through a communicating passage or tunnel also located near the stairway. 3. The net effect produced by propelling air from one end of a work area and exhausting air from the opposite end of the same area is to create
ETC 00125
C~069 [ 4
3 a place somewhere in between where there is little or no air movement. This area was located approximately 20 feet from the wall fan exhausters. Incidentally, this is just the area where most of the heavy welding fume is produced in the shop. 4. To summarize: 1. Welding fume is being recycled, this is not acceptable to OSHA* 2. Welding fume is often not effectively exhausted, this is not
acceptable to OSHA.** Central Shop and R&D Shop, Impression 1. Preliminary industrial hygiene ventilation evaluations did not reveal
welding fume accumulations which would constitute OSHA type deficiencies. Maintenance Shops
Recommendations*** - Sodium 1. Welding fume in those areas of routine heavy fume production can be
effectively controlled by using ducting systems and air movers of sufficient size to provide a capture velocity of greater than 100 feet a minute at the fume source. The captured fume should be transferred to an exhaust point where the fume will not return to the area. A manufacturers description of one such system is attached. It would be best if one of these .POINT OF SOURCE exhausting systems is installed for each teavy production routine welding station in the area, (about three or four)
*"A11 air replacing that withdrawn shall be clean and respirable" 1910.252; >4. ** This has the net effect of reclassifying the process area as a confined
space and to require OSHA controls for confined space welding. *** No recommendations are presented for central shops or R&D shop areas.
ETC 00126
F-0691S
4 If you decide to persue this method of control, it is recommended someone also specify a maximum allowable noise exposure for fans and motors, since in the past, some of these systems haven't been used because of noise irritation. 2. It is also recommended that a motor be purchased with sufficient static pressure capability to move the exhausted air through a duct to a riser stack of some sort. The riser stack should be sufficiently high and out in the open to avert the present recycling problem.
C
C
F-06916
ETC 00127
I
\
Solve uoun felattt vetvTM*.,^rU^;feo{tteMt4, cvitka
HI-L9 OEIBIM OTE-OElflBSTEi
C\\
New^5tate Regulations now ^mak._e_rjt__ mandatory- th/ at ail welding fumes be ex-
hausted from the working area' during--the^welding .operation regordless of the
size of^tlTe'-operotion. Blower'sj.modern. method of fume'disposal collects end pulls
the fumes oncTfieat away AT ITS SOURCEN^^. using high velocity exhaust hoods
with fan exhausting^outdoors. ,ln this/way all fumes'and'smoke ore pulled away
/ / *I
\^
-before they have a chance to rise and spreod a|l .over the shop area.
(` '
Here you need only a small volume of ventilating oir for each Hood. This reduces
fan power consumption to a low minimujTt.
Truly . . . "IT'S THE POSITION YOU ARE IN THAT COUNTS."
BLUE ISLAND/ ILLINOIS
P-0691 8
ETC 00129
t
c:
I !
f W--
.rt ^`-T,">' Mr .-+T ***'* i i
i II&MlL^vIlI
' & cjzzy ,:/r..-.-2
...___
Model 813-E (left) Exhauster F<_--e Collector. (Shown with blower to-.' Note extreme range of Hood for we ping position use. The full circle rc*ction of hood ond flex hose or* rp-plable elbows . . . the finger-tip co-trol counter balance of the cdius* -g balance structure crms that hole or any desired position for efficient op eration.
Elesrs votyjr
c ''yihori.-arT/nv <y :^**e*^
w u^
u ve^ u
U U Jw U Vsy
Gii *?vj^iT3 O
jiff
L ki
mmU
7&
u A.
vi/ w
U VLy U b id
p -n f? /'Tv
,,
GE33 yGOT VJ?l A. ki kd W tjJ-iivi) qasi!iiiy g*js
tj
cl
^
P'd w
i
1* Vi
e.
e!;
Fumes Collected at Source: Because this collector has almost universal flexibility the rotatable exhaust Hood can be placed in the best position to effectively collect welding fumes. Hood (made of insulating material) may be placed 18 inches diagonally above the arc and so ventilate many welding operations without Hood movement. No Fumes escape into general `shop area.
Unlimited Working Range: Model 813-E moves on a 9 foot horizontal radius. Vertical range extends to about 11 feet above floor. (Note diogramatic sheet for details.)
Workmanlike Construction: All exhausters are designed and manufactured under careful specifications to meet rigid industrial as well as government requirements. Rotatable elbows are made of heavy cast material mounted on steel brackets. These support the counter balance arms made of structural steel and connect to the 6 inch flame proofed retractable Hose and Ball Jointed exhausting Hood.
Low Maintenance Costs: Use of a minimum of working parts insures (aw maintenance cost and longer product life.
Simple Installation: Wall bracket support accompanies
C'h unit. Simple installation data and instructions are uded. Each unit fully assembled. Fan and Motor platform furnished at extra cost when desired.
Collects Fumes at Source - - Wide Positions - - Minimum Heat Loss -
Exhaust Fan and Motor
Blower's general ex hauster or blower -p-s are available in all s ees to produce most nee pep oir volumes ond p-essures. In either be c'r direct drive all rr.c'crs are ball bearing U. S. Electric types. With p*oper selection multiple :nstallations of exhaus'ers to one blower fan con be mode. Enginee'log advice is availcble cs c Blower service wherever needed.
F-06919
ETC 00130
Model 913-E Long Arm extention Exhauster Fume Col lector. Extra sturdy industrial construction of this special unit assures eose of operation at 15 feet distance of hood at the maximum height of operation. Extra heavy support of wall bracket assures effective needed sup
port for heavy volume exhausting of fumes at full range. Fire proofed 6 inch flex hose and adjusting rotating hood make possible the same low power consumption qs Model 813-E.
-f"
ange of Hood Low Maintenance
Light weight/ portabie rr.cdc! of sturdy aluminum construction with self-locking wheels, ideal for inac cessible ventilating.
Model 850-E . . Portable Exhauster Blower accom modates multiple lengths of flex-hose--10 ft. each with quick coupling attachments. Basic for mine exhousting or where exhausting problems in deep well or hole is essential. 220 Volt A. C., 60 Cycle, 1 H.P., 3600 PRM.
--
:
Motors and blowers available for any exhausting requirement: fumes - grinders - dust - smoke. Write for additional information or for specifications to fit your plant's needs.
!&
..... .'
F-069?0
ETC 00131