St* Lonis Mr. T. H. Wheeloofc New York Yow Nmo, February 26# 1953 C. H. McKechnle Boston# Massachusetts Thank you very mob for the nfermetd memorandum and to*i attached drawing of tha heating unit given to yon by Messrs. McKechnle when they called on your recently. Tha 500,000 up to 3,500,000 OTU per hour units described appear very similar to our own design. You Indicated that these people have our Bulletin P-130 on design and while the drawing does not show all detail desired# no doubt# these engineers have worked out a satisfactory design. We would gather this to be the case from the information at hand. Also, since the units currently are using Socony Vacuus1 s heat transfer oil# this would indicate that a direct change over to Aroclor could be made without any major changes. About the screening (described as relatively coaratmesh strainer) filter in the systeg we would suggest leaving tills as is. In addition# however, it would be desirable for the people using the equipment to filter the heatlranefer medius periodically using a convenient external# portable# or if desired# permanently set filter employing Fuller's earth or Attapulgus clay. This filter, of course, should not be an integral part of the heat exchanger Systran as it would restrict flow. I am mentioning this because in your memorandum you indicated to Mr. McKechnle the desirability of having a filter in the system rather thaa a coarse mesh strainer. I don't know exactly what you meant by this that the earthen filter should be in the system. To answer the two spec Ifla questions raised, we comment am follows* 1* You asked for the specific heat expressed in terms of BTB's per pound, per degree ? of Aroclor 1243 at 1QGF, 300?, and 500F. Attached is a copy of Bulletin P-130 sad we wish to refer to Table 1# sad also a copy of Bui lotto P-U5 sad we wish to refer to Figure 3# Page 10. Hare the specific heat of the Aroclors is glvem in tarns of calories (l5C)_per gram per degree C over toe tempera ture range of o - to 300C in too caso of Figure 3* sad la the case of Tablo I. Bulletin F-130# over toe tsaporsturo range of 50C (122F) to 300*8 (572*7)* DSW 550951 STLCOPCB4089368 Pag* 2 Reading these values directly la the Fahrenheit scale will give the desired date elnee the conversion rector of calories per gran per degree ceatrlgrade to SSS's per pound per degree Fahrenheit Is 1. This relation holds# of course# by definition since one calory la required to host one gran of water one degree eentrigrede end one BS0 la required te heat one pound of water one degree Fahrenheit. Accordingly# speciflo heat la defined as a ratio of comparison of the given substance with water. If the specific heat la# say--2, it requires two calories to heat one gran of the material lC or two&fO's to heat one pound 1F. For Mr. McKechnie to get the values at 1QGF, 3QOF, and 500P all he has to do is to plot the data given In Table I# Bulletin P-130. In fact, it can be estimated very closely without even going to the trouble to plot it. It -ill be in order If you will mention that these specific heat values are certainly on the conservative side. You will recall our having run into systematic errors in different methods of determining this data and that we are still using the lowest values. You may also want to point out that when comparing the specific values of the Aroclor with similar values# say--for Sooony Vacuum's heat transfer oil# that much higher density or specific gravity of the Aroclor vs. the petroleum oil should not be overlooked. 2. In answering the second question about probable Aroclor loss# the best thing to say la that the system will have to be tight. In other words, it is simply Impractical to operate these systems unless they are relatively free of leakage. Accordingly# your own estimation of lo make-zap may appear somewhat on the high side for a properly operating unit but 1 would guess it is about as good a figure as ws can give on this point. In your memorandum you indicated that yon will pass along to Mr. McKechnie this information via the gverett offlea* This struck me as a rather round-about way of getting the informa tion to Mr. McKechnie and# therefore# I an passing along ay comments both to you and to the Everett office as a 3 convenience to you so that you will not have to transcribe at least ay comments. You aey have aertala things that you win went to add# however. You asked that Mr. McKechnie's drawing be returned and# therefore# I am attaching it. rpts fern P 0* DSW 550952 STLCOPCB4089369