Document oD1aeZmgvGxXodpOqrmDnL2MD
U.S. ENVIRONMENTAL PROTECTION AGENCY Office of Pesticides & Toxic Substances Washir.coon, D.C.
Submitted in Partial Fulfillment of Contract No. 68-02-3168 Technical Service Area 3 Work Assignment No. 2
EPA Project Officer Richard Guimond
ASBESTOS PRODUCT TEST RESULTS
Prepared by: Nancy Roy Paul LaShot^. David Cogley
February 1980
PLAINTIFF'S
EXHIBIT
CUR-***
GCA CORPORATION GCA/TECHNOLOGY DIVISION Bedford. Massachusetts
SAMPLING OF 3RAKE REPAIR WORK
On September 21, 1979 samples of ambient particulate were collected in a garage while brake work was being performed. A representative of Nilfisk of America was present to demonstrate the value of Nilfisk control equipment in brake lining repair work. Sampling was permitted on the condition that the facility and its location remain anonymous.
Three types of ambient samples were collected:
In the garage away from the workspace (background levels).
Near the workspace while Nilfisk devices were in use. Near the workspace without any controls.
Table 1 shows the resuit of analysis of such samples by Scanning Electron Microscope (SEM).
TABLE 1
BACKGROUND LEVELS OF ASBESTOS
SAMPLING LOCATION
About 25' from workspace
About 55' from workspace
DURATION (Min.)
6
60
SAMPLING FLOW (1pm)
2.2
2.2
FIBERS 4 4
FIELDS 130 450
SEM CONCENTRATI
(f/cc)
0.21
0.06
Samples away from the workspace were collected during brake work taking place inside Nilfisk control equipment. They would typify fiber levels in the garage from day to day since* as Table 2 shows, fiber re* lease when the Nilfisk devices were used. Release may be seen to be minimal.
Clearly, the one fiber collected during the Nilfisk controlled work could have come from background contamination.
Two sets of samples were collected near the workspace when brake work was being done in the usual manner; without Nilfisk controls, first, a brake housing was removed and cleaned by being struck repeatedly with a hammer. Second, the worker opened a brake housing, cleaned it with a jet of compressed air, then swept up all the debris which had accumulated on the garage floor. Employees and supervisors gave assurance that these procedures were routine.
71
Zo
5
f" `\ Z M
uz
8
O .O
1mo/>
Jov
m
lloAA
MO rc- oo
8
a
a
w< Cu
O
Sa>3 xtoi
8-
3g L
t^1
71
ae
<j* <N (N <N <N
5
u
Si zo
t-
*
O' 00
tA
<N
8.5
(N
85
M j
Me-
*j x
su
s8
ij 4_1
U) x
3fl <H8
**
o>
Mw
*0wc
* <44
<44
S'zw H
kl
OS *30
-e Xu
>S
44 V
731 X<0
V kl A 43 X
D 4s7
X0 VI kl
44
3 S'
Z *
c u3
O *0
I
0) M <0 u S' iO
u W (Q 3 0)
H
Q>
8*1
M <0
S | x. 2OC <44 o5
4c4 D>
44 44 (A C 30 IQ U & 44 X VX
i> ,,k03l XW,,
3*^44
*mC
S 0)
X W* *(X0
C 9 ki
O *0 Q
X 0
49144
Is
T) V X
XVkl 4b3
C) 44 0
oC 4k4i
44
s
2
44
X o
3 ki X
44 kl
5
<M
2
M
<0 ki
00 JQ
oC
N ilf is k exhaust 10 2.2 0 330
I
oz
x
Jl 71
S
VUy
y u-
^ ^n as
^ O OO
ion r<-r 7oi ~o o o o' o'
a aV0 4U>
XSVut'
XUU)
S
Vo !/)
X
8 8<9y44
m
wy o
y i<AN
4) U4> 4y)
a* w
ff2
1
u
X
AaUyt)
1 iS'S 14
8 8
c
80u)
431>
OU
4>
Xki Os
ugk-ti m
y o
<yu MlA
Oust dispersed more rapidly and extensively with compressed air cleaning as the results 25 fuet from the workspace indicate.
Three samples of dust were also collected during garage visit:
3rake dust - rear brakes. 3rake dust - truck front brakes Overhead dust on rafters
~-
- ----
Optical microscopy did.not reveal- any asbestos in these-samples. ~ 3rake dusts were primarily quartz and carbon, while overhead dust was almost entirely cellulose. SEM analysis revealed a small number of very short asbestos fibers among these more visible substances.