two most important peaks in the chromatograms. The ratio of amts, of these pyrolysis prods, obtained under standardized conditions should be a good basis for estimating the branching degree in alkylbenzenes.
Instrument: Varian HyFi III Col. L/d: 300cm x 3mm, i.d., glass Support/mesh size: Gas Chrom P, 80-100 mesh Carrier gas/flow rate: N2 25 ml/min Oper. Temp.: Prog. 50" to 250C at 20/min P.etention Data: Pyrograms, p. 679 Compds. Sepd.: Alkylbenzenes
Detector: FID Stat. ph./concn.: SE-30, 15%
.
2231
12-27-69
No. 69-2231
SOME STUDIES ON GLC COLUMN PERFORMANCE WITH RESPECT TO SAMPLE SIZE
W. J. A. VandenHeuvel and G. W. Kuron (Merck Inst, for Therapeutic Research,
Rahway, N. J. 07065)
J. Chromatog. Sci. 7.* No. 11: 651-55 (Nov. 1969) . Presented at 5th Intern.
Symp. on Advances in Chromatog., Las Vegas, Nevada, Jan. 20-23, 1969
A study of the relationship between col. performance (efficiency, overload and sepn.) and diam. and sample size in the GC of steroids showed that smaller diam. cols, were more efficient with small samples (less than 30 yg/component), whereas at higher levels (60-500 yg) performance of the larger col. was superior.
Instrument: Barber-Coleman Model 5000
Detector: FID
Col. L/d: (I) 8 ft x 4 mm, i.d.: (II) 8 ft x 11 mm, i.d., glass U-tubes
Stat. ph./concn.: (I) 0V-17 (1.8%); (II) SE-30 (2%) Both used with both cols.
Support/mesh size: Gas Chrom P (60-80 mesh), a.w. and silanized
Carrier gas/flpw rate: Gas not stated Rates (I) 35 ml/min; (II) 250 ml/min
Oper. Temp. (I) 240C; (II) 250C
Retention Data: Chromatograms, pp. 652-55
.
Compds. Sepd.: Coprostane, 5-cholestene, coprostanol, cholestanol and some
derivs. of the sterols
2232
12-27-69
No. 69-2232
~ AJMETHOD FOR THE COLLECTION OF AIR SAMPLES FOR ANALYSIS BY GAS CHROMATOGRAPHY
R. Van Heuten and George Lee (Liberty Mutual Research Center, 71 Frankland Rd.,
Hopkinton, Mass. 01748)
Am. Ind. Hyg. Assoc. J. 30, No. 5: 465-69 (Sept.-Oct. 1969)
A method is descr. for collecting and transporting air samples that are to be i: anal, for solvent vapors by GC. Samples are collected in standard 4 oz. French ! ; square sample bottles which are filled by means of an aspirator bulb. The
bottle caps are fitted with a seal made from 3 thicknesses of 2.0 mil, type 18 Saran, backed with 1 thickness of 8.0 mil latex rubber (Fig. I, p. 466). Before inserting the gasket, a 1/16 in hole is drilled in the bottle cap, so that samples can be withdrawn for anal, by inserting a syringe needle and puncturing the gasket. In addn. to the gasket, the bottles contain a mercury seal so that after removal of a sample, the hole in the cap can be covered with adhesive and resealed by inversion for indefinite holding. Sampling kits contg. 17 bottles packaged for protection during shipment and weighing approx. 10 lbs. have been tested after air and rail transport from remote locations and shown to give satisfactory performance. GC sepns. of solvent-air samples collected and held in the descr. sampling bottles are illustrated.