Document o9p35pZpNaaqEqGr3BQz50J77

Monsanto CALL REPORT - ORGANIC DIVISION '* DICTATE IN SEQUENCE: 1. HEADING INFORMATION 2. NAMES OF ADDRESSEES 3. NAMES OF CARBONEES 4. IMMEDIATE ACTION NEEDED 5. REPORT ON CALL CUSTOMER NAME DATE OF CALL CITY AND STATE Jiffy Fry Foods DATE RECEIVED 1DA0TE/T1YP3ElT/69^- Crooks ton. Minn. ___10/21 - 10/21___ CUSTOMER MAILING LIST CHANGES - SERVICE CENTER USE ONLY NAME AND TITLE tor TAKE ON OFF MP MAG. CATEGORY CODES REPORT CAPTIONS: 1. OBJECTIVE 2. PERSONS CONTACTED 3. RESULTS 4. ACTION REQUIRED ................... REGION , St. Louis \ ... SERVICE CENTER Chicago g SALESMAN J.J. Roder/sgb_____: J.R. Fallon JFAU, TO rr 9.8. Roush - DBOUS ^ J*S Fullman - B.Y. Soger Irwin - Houston PSRSOHHEL COHTACTEDl Walt Davis - Bey Equipment Company John Dow - Foremost Foods Co. Berman Gregg - Jiffy Fry. OBJECTIVE: Review TT 01 installation. RESULTS: On the surfact Key Equipment appears to have done a good Job of laying out the system and piping It up correctly. A couple areas of question and they may not be serious are: 1. Expansion tank slightly lower than some of the process piping. 2. Y type Strainer located In a bypass portion of the process piping instead of at the suction of the pump. 3. Beater pumps are Gould 3x4x11 (10$ impeller) - Davis was not sure who actually sized the and if any effort was made to actually size the according to system requirements. The process piping and heaters were filled with THERMIKOL after a partial vacuum had been pulled on the system. The fryer coils were blocked off prior to filling because leaks were found to each of the foulr colls during a routine air pressure test. The fryer mfgr. was called to to eorrect the situation. Walt Davis asked If we had any recausendations regarding a continuous THEBMITfOL detector lttlch could be used to monitor the cooking oil or a siople lab tost that the operators could perform periodically to totoct YBERMXS0& contamination. In view of the four leaky colls It would relieve a number of people to know that ssoe check other than odor was being used. (Attention Jack and Don: Any recommendations!) 5-331A (REV. 12/M) The plant heating loop was also blocked off because all of the piping had not been completed. The only area of concern here appears to be the Kodine units which I believe are their standard coll units. THERMIKOL temperature in this zone would be 200 F or less. ...continued............... ' "" 1 0S\N 3*3408 EXTRA COPY STLCOPCB4096607 Monsanto CALL REPORT - ORGANIC DIVISION DICTATE IN SEQUENCE: 1. HEADING INFORMATION 2* NAMES OF ADDRESSEES 3. NAMES OF CARBONEES 5. REPORT ON CALL REPORT CAPTIONS: 1. OBJECTIVE 2. PERSONS CONTACTED 3. RESULTS 4. ACTION REQUIRED CUSTOMER NAME CITY AND STATE XXp . Jiffy Pry DATE OF CALL 10A3/69 ' DATE RECEIVED DATE TYPED CUSTOMER MAILING LIST CHANGES - SERVICE CENTER USE ONLY NAME AND TITLE PUT TAKE ON OFF MP MAG. CATEGORY CODES REGION SERVICE CENTER . SALESMAN TO Page # 2 cc Tho design of equipment appears to he pretty conservative frm the standpoint of heat exchange earface. Each fryer is equipped with wo - 150 foot sections of 3 inch coll which Is about twice the calculated figure. Davis Is not too concerned about heat transfer surface but he would like to get a hotter idea for future plants which the actus! re* quiresents should he* In line with this he asked if we could provide e flow recorder and temperature recorder (inlet end Outlet) which could he tsoved about to check actual S13? requirements at various users* I*n not sure how we can handle this budget wise but it sigh give us some valuable design information for future application** (Jack --dpy cosesats?) Original order was 4t5oo gallons. Actual shiptsent was only about 35^0 gallons FS-1 because of x&xl&um T/T shipping weights* As they need more fluid can they receive the remainder at the $.23Ah price (Jack)T ACTIOS REQUIRS)* Jack ft Don --tfberalnol detector or test* Jack *** Plow ft tessper&ture recorders* Jack *-- Therrsinol price of future requirements. ROTE* Jack Scaae photos attached* 5-331A (REV. 12/68) EXTRA COPY DSW 343409 STLCOPCB4096608