Document o9bbqD2grL6VKKb3XejDMo2nE
international Heater Co.
Boilers
I m e r n/rri o n/i l jIzcojsfomy
Reg. V. S. Pat. Off.
SMOKELESS BOILERS
Sirfact
STEAM
WATER
of Length
Feel Bed Of '
Member Biting Nomber Rating laches Boiler
62-26 71-26 72-26 81-26 82-26 71-31 80-31 81-31 90-31 91-31 100-31 101-31 110-31 80-38 81-38 90-38 91-38 100-38 101-38 110-38 111-38 120-38 71-47 72-47
81-47 82-47 91-47 100-47 101-47 110-47 111-47 112-47 121-47 130-47
131-47 140-47 141-47 142-47 151-47
2000 26-62
3300
2100 26-71
3475
2300 26-72
3800
2400 26-81 3975
2600 26-82 4300
2700 31-71
44S0
2850 31-80 4700
3100 31-81
5100
3250 31-90 5350
3500 31-91
5750
3650 31-100 6000
3900 31-101 6400
4050 31-110 6650
4150 - 38-80 68S0
4450 38-81
7350
4700 38-90
77S0
5000 38-91
8250
5250 38-100 8650
5550 38-101 9150
5800 38-110 9550
6100 38-111 9950
6350 38-120 10450
6900 47-71 11500
7500 47-72 12500
7900 47-81 13150
8500 47-82 14150
8900 47-91 14800
9300 47-100 15500
9900 47-101 16500
10300 47-110 17150
10900 47-111 18150
USOO 47-112 19150
11900 47-121 19800
12300 47-130 20450
12900 47-131 21450
13300 47-140 22100
13900 47-141 23100
14500 47-142 24100
14900 47-151 24750
26x28 26x32
26x36 26x40 26x44 31x28 31x32 31x36 31x40 31x44 31x48 31x52
31x56 38x32 38x36 38x40 38x44
38x48 38x52 38xS6 38x60 38x64 47x40 47x45
47x50 47x55 47x5S 47x60 47x60 47x60 47x65 47x65 47x65 47x70 47x70 47x70 47x75 47x75 47x75
53 57}* 61
65 }* 69 57}*
61 65}* 69 73}* 77
81}* 85 61 65}* 69 73}* 77
81}* 8S 89}* 93 69 75 79 85 89 94 99 104 109 114 119 124 129 134 139 144 149
TAPPIN6S
STEAU
WATER
Snpply
2-3}* 3-3}* 3-3}* 3-3}* 3-3}*
2-4 2-4 2-4 3-4
3-4 3-4 3-4 3-4
2-5 2-5 3-5 3-5 3-5 3-5 3-5 3-5 3-5 2-6 3-6 3-6
3-6 3-6 3-6 3-6 3-6 4-6 4-6 4-6 4.-6 5-6 5-6
5-6 5-6 5-6
Retorn Sopply
2-3}* 2-3}* 2-3 J* 3-3}* 2-3}* 3-3}* 2-3}* 3-3}* 2-3}* 3-3}* 2-4 2-4 2-4 2-4 2-4 2-4 2-4 3-4 2-4 3-4 2-4 3-4 2-4 3-4 2-4 3-4 2-5 2-5 2-5 2-5 2-5 3-5 2-5 3-S 2-5 3-5 2-5 3-5 2-5 3-5 2-5 3-5 2-5 3-5 2-6 2-6 2-6 3-6 2-6 3-6 2-6 3-6 2-6 3-6 2-6 3-6 2-6 3-6 2-6 3-6 2-6 3-6 2-6 3-6 2-6 3-6 2-6 3-6 2-6 5-6 2-6 5-6 2-6 5-6 2-6 5-6 2-6 5-6
Retorn
2-3/,
4-3}* 4-3}*
4-3}* 4-3}* 2-4 2-4 2-4 4-4 4-4 4-4 4-4 4-4 2-5 2-5 4-5 4-5 4-5 4-5 4-5 4-5
4-5 2-6 4-6 4-6 4-6 4-6 4-6 4-6 4-6 4-6 4-6 4-6 4-6 6-6 6-6 6-6 6-6 6-6
Inside Cfaim. Chim. Dim. of
Dim. Height Ashpit Inches Feet Inches
12x12 50 25*4x32 12x12 50 25}4x35}* 12x16 50 2S5*x40 12x16 55 2514x43}* 12x16 60 2S 14x48 12x16 55 30/<32 12x16 55 30)4x35 }* 16x16 90 30)4x40 16x16 50 30)4x43 J* 16x16 50 30)4x48 16x16 55 30)4x511* 16x16 55 30)4x56 16x16 60 30)4x591* 20x20 55 36}*x35}* 20x20 55 36}*x40 20x20 60 36}*x431* 20x20 65 36}*x48 20x20 70 36}*x511* 20x20 70 36}*xS6 24x24 60 36}*x59}* 24x24 60 36}*x64 24x24 65 3614x671*
24x24 65 48)*x44
24x24 65 48)4x50 24x24 65 48)4x54
24x28 65 48)4x60 24x28 65 48)4x60 24x28 65 48)4x64 28x28 65 48)6x64 28x28 65 48)4x64 28x28 65 48)4x70 28x28 65 48)4x70 30x30 6S 48)4x70 30x30 65 48)4x74 30x30 65 48/x74
30x30 70 48)4x74
30x30 70 48)4x80 30x30 75 48)4x80 30x30 75 48)4x80
SERIES
26 "
Height of Water Line........... --......... 47 " Height to Supply Outlets................ 58}*" Add to height for Trimmings--------- 11 " Add to length of Boiler for Smoke
Box .................................................... 7X~ Width of Boiler.................. ............. ..... Width of Boiler includ. Trimmings 40 " Height from floor to Center of Re-
turn Tappings................................... 20 " Height of Fire Box to Crown____ 22 " Height, Grate to Middle of Feed
16 " Size of Smoke Flue............................... 10 "
STEAM
31 "
50 " 62/" 11 "
.38 "
54- " 67yt~ 11 "
7/" S'4"
45 " 53 "
20/" 21 " 24 " 26 "
18 " 20 " 12 " 16 "
47 " 59 " 73 " 12 "
61 "
21}*" 26 "
20 " 20 "
Size of Feed Door_......................... 9x17 9xL7 11x21 10x17
00 *
WATER .26 " "31 "' 38 " 47 "
55 " 59 " 66 " 73 "
7}*" 7)4" 8/" 8)4" 36 " 42 " 48 " 59 "
20 " 20}*" 21 " 21}*" 22 " 24 " 26 " 26 " 16 " 18 " 20 " 20 " 10 " 12 " 16 " 20 " 9x17 9x17 11x21 10x17
Trimmings as listed below are sent with each Steam Boiler without extra charge.
One 8-incb Economy Deegan Regulator with lever, weight, chains and pulleys.
One Water Gauge complete with glass and brass rods.
Two Brass Compression Cocks.
One Steam Gauge with Pigtail Syphon.
One Safety' Valve.
Outlets for Safety Valves are tapped in accordance with the A. S. M. E. Code.
No Trimmings are sent with Water Boilers.
Fire Tools. With every Steam and Water Boiler there is sent free a Brush, Poker and
iper.
_ SPECIAL CATALOG WILL BE SENT ON APPLICATION
230
international Heater Co.
Boilers
InTERH/ITIOn/IL ECONOMY SECTIONAL BOILERS
STEAM
Member
35-19 4-19
45-19 5-19 4-26
45-26
5-26 55-26
6-26 5-31 55-31 6-31 65-31 7-31 75-31 8-31 85-31 5-38 55-38 6-38 65-38 7-38 75-38 8-38 85-38 9-38 95-38 10-38
105-38 11-38
Bating
700 825
975 1100 1000 1200 1300 1500 1600 1650 1900 2050 2300 2450 2700 2850 3100 2500 2800 3050 3350 3600
3900 4150 4450 4700 5000 5250 5550 5800
Coal
Capacity Poinds
195 225 265 295 290 340 375 42S 460 480 545
590 645 70S 770 825 890 685 770 835 920 985
1070 1135
1220 1285
1370 1435 1S20 1585
Evaporative Power
9.6 9.6
9.6 9.6 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3
9.3 9.3 9.3 9.3 9.3
9.7S 9.75 9.75 9.75 9.75 9.75 9.75 9.75 9.75 9.75 9.7S
9.75 9.75
Surface of
Fnel Bed Inebes
19x20 19x24 19x28 19x32 26x24 26x28 26x32 26x36 26x40 31x32 31x36 31x40 31x44
31x48 31x52
31x56 31x60 38x32 38x36
38x40 38x44 38x48 38x52 38x56 38x60 38x64
38x68 38x72 38x76
38x80
Lenitb
of Boiler inches
25}*
29 33}* 37 29 .33}* 37 41}* 45 37 41}* 45 49}* 53 57}*
61 65}* 37 41}* 45 49}* 53 57}* 61 65}* 69 73}* 77
81}* 85
Inside Din.
of Ashpit Inches
22x24 22x27}*
22x32 22x35}* 25/x27}* 25*4x32
2S/x35>*
25*4x40 25/x43}* 30}*x35}*
30)4x40 30)4x43 }* 30)4x48
30)4x51}* 30)4x56 30)4x59}* 30)4x64 36}*x3S}* 36}*x40 36*4x43}*
36}*x48 36}*x5l}* 36}*x56 36}*x59}* 36}*x64 36}*x67}* 36}*x72 36}*x75}5 36*4x80 36*4x83}*
TAPPIH6S** Seppiy_______Betarn
2-3" 2-3" 2-3"
2-3" 2-3}*" 2-3}*" 2-3}*" 2-3}*" 2-3}** 2-4" 2-4" 2-4" 2-4" 3-4" 3-4" 3-4"
3-4" 2-5"
2-5" 2-5" 2-5" 2-5" 2-5" 3-5" 3-S" 3-S" 3-5" 3-S" 3-5" 3-5"
2-3" 2-3" 2-3" 2-3" 2-3}*" 2-3}*" 2-3}*" 2-3}*" 2-3}*" 2-4" 2-4" 2-4" 2-4" 2-4" 2-4" 2-4" 2-4"
2-5" 2-5" 2-5" 2-5" 2-5" 2-5" 2-5" 2-5" 2-5" 2-5" 2*5"
2-5" 2-5"
timber
6-47 65-47
7-47 75-47
8-47 85-47 B9-47
9-47 B95-47
95-47 B10-47
10-47 B105-47
105-47
Ratios
5300 5900 6300 6900 7300 7900 8300 8300 8900 8900 9300 9300 9900 9900
Surface of Evaporative Enel Bed
Power_______ inches
. 9.7 9.7 9.7
- 9.7 9.7 9.7 9.7 9.7 9.7 '9.7 9.7 9.7 9.7 9.7
47x50 47x55 47x60 47x65 47x70 47x75 47x70 47x80 47x70 47x8S 47x70 47x90 47x70 47x95
Length of Boiler Inches
54 59 64 69 74 79 84 * 84 89 89 94 94 99 99
Inside Dim. of Ashpit Inches
48/xS4 48)|x60 48)*x64 48)6x70 48)6x74 48)6x80 48)6x74 48/x84 48)6x74 48)6x90 48)6x74 48)6x94 48)6x74 48)6x100
TAPPINGS
Seppiy
Retvrn
2-6" 2-6" 2-6" 2-6" 3-6" 3-6" 3-6" 3-6" 3-6" 3-6" 3-6" 3-6" 3-6" 3-6"
2-6" 2-6" 2-6" 2-6" 2-6" 2-6" 2-6" 2-6" 2-6" 2-6" 2-6" 2-6"
2-6" 2-6"
SERIES
19"
Height of Water Line.......................................................... 44" Height to Supply Outlets................................................. 53" Add to height tor Trimmings.......................................... 9" Width of Boiler, including Trimmings................... -- 32" Add to length of Boiler for Smoke Box......... .......... 6" Height from floor to Center of Return Tappings.. 18" Height of Fire Box to Crown....... ................................ 22" Height, Grate to Middle of Feed Door...................... 16" Size of Smoke Flue.--........................................................ 9" Size of Feed Door.............................................................. 9x14"
26"
47" 56/" 11" 40"
7}*" 19" 22" 16" 10" 9x17"
31" 38" 47"
50" - 54"
59"
62%"
67X'
72}*"
11" 11" 12"
45" 53" 61"
7H"
8
w
19J4"
19/"
21}*"
24" 26" 26"
18" 20" 20"
12" 16" 20"
9x17" 11x21" (2) 10x17'
Trimmings as listed below are sent with each Steam Boiler without extra charge. One 8-inch Economy Deegan Regulator with lever, weight, chains and pulleys.
One Water Gauge complete with glass and brass rods. Two Brass Compression Cocks. One Steam Gauge with Pigtail Syphon.
Sutlets^fdr Safety Valves are tapped in accordance with the A. S. M. E. Code.
Sizes marked with a star as regularly shipped have a bridgewall limiting the grate to con venient length for hand firing. Full length grates are shipped only when specified on the order.
The Economy Line of Boilers does not require any headers. Plug and bush flow and
return openings to suit size of flow arid return mains. SPECIAL CATALOG. WILL BE SENT ON APPLICATION
In addition to Boilers listed in this book we also manufacture a complete line of Round Steam and Hot Water Boilers and Hot Water Supply Boilers.
231