Document o9bbqD2grL6VKKb3XejDMo2nE

international Heater Co. Boilers I m e r n/rri o n/i l jIzcojsfomy Reg. V. S. Pat. Off. SMOKELESS BOILERS Sirfact STEAM WATER of Length Feel Bed Of ' Member Biting Nomber Rating laches Boiler 62-26 71-26 72-26 81-26 82-26 71-31 80-31 81-31 90-31 91-31 100-31 101-31 110-31 80-38 81-38 90-38 91-38 100-38 101-38 110-38 111-38 120-38 71-47 72-47 81-47 82-47 91-47 100-47 101-47 110-47 111-47 112-47 121-47 130-47 131-47 140-47 141-47 142-47 151-47 2000 26-62 3300 2100 26-71 3475 2300 26-72 3800 2400 26-81 3975 2600 26-82 4300 2700 31-71 44S0 2850 31-80 4700 3100 31-81 5100 3250 31-90 5350 3500 31-91 5750 3650 31-100 6000 3900 31-101 6400 4050 31-110 6650 4150 - 38-80 68S0 4450 38-81 7350 4700 38-90 77S0 5000 38-91 8250 5250 38-100 8650 5550 38-101 9150 5800 38-110 9550 6100 38-111 9950 6350 38-120 10450 6900 47-71 11500 7500 47-72 12500 7900 47-81 13150 8500 47-82 14150 8900 47-91 14800 9300 47-100 15500 9900 47-101 16500 10300 47-110 17150 10900 47-111 18150 USOO 47-112 19150 11900 47-121 19800 12300 47-130 20450 12900 47-131 21450 13300 47-140 22100 13900 47-141 23100 14500 47-142 24100 14900 47-151 24750 26x28 26x32 26x36 26x40 26x44 31x28 31x32 31x36 31x40 31x44 31x48 31x52 31x56 38x32 38x36 38x40 38x44 38x48 38x52 38xS6 38x60 38x64 47x40 47x45 47x50 47x55 47x5S 47x60 47x60 47x60 47x65 47x65 47x65 47x70 47x70 47x70 47x75 47x75 47x75 53 57}* 61 65 }* 69 57}* 61 65}* 69 73}* 77 81}* 85 61 65}* 69 73}* 77 81}* 8S 89}* 93 69 75 79 85 89 94 99 104 109 114 119 124 129 134 139 144 149 TAPPIN6S STEAU WATER Snpply 2-3}* 3-3}* 3-3}* 3-3}* 3-3}* 2-4 2-4 2-4 3-4 3-4 3-4 3-4 3-4 2-5 2-5 3-5 3-5 3-5 3-5 3-5 3-5 3-5 2-6 3-6 3-6 3-6 3-6 3-6 3-6 3-6 4-6 4-6 4-6 4.-6 5-6 5-6 5-6 5-6 5-6 Retorn Sopply 2-3}* 2-3}* 2-3 J* 3-3}* 2-3}* 3-3}* 2-3}* 3-3}* 2-3}* 3-3}* 2-4 2-4 2-4 2-4 2-4 2-4 2-4 3-4 2-4 3-4 2-4 3-4 2-4 3-4 2-4 3-4 2-5 2-5 2-5 2-5 2-5 3-5 2-5 3-S 2-5 3-5 2-5 3-5 2-5 3-5 2-5 3-5 2-5 3-5 2-6 2-6 2-6 3-6 2-6 3-6 2-6 3-6 2-6 3-6 2-6 3-6 2-6 3-6 2-6 3-6 2-6 3-6 2-6 3-6 2-6 3-6 2-6 3-6 2-6 5-6 2-6 5-6 2-6 5-6 2-6 5-6 2-6 5-6 Retorn 2-3/, 4-3}* 4-3}* 4-3}* 4-3}* 2-4 2-4 2-4 4-4 4-4 4-4 4-4 4-4 2-5 2-5 4-5 4-5 4-5 4-5 4-5 4-5 4-5 2-6 4-6 4-6 4-6 4-6 4-6 4-6 4-6 4-6 4-6 4-6 4-6 6-6 6-6 6-6 6-6 6-6 Inside Cfaim. Chim. Dim. of Dim. Height Ashpit Inches Feet Inches 12x12 50 25*4x32 12x12 50 25}4x35}* 12x16 50 2S5*x40 12x16 55 2514x43}* 12x16 60 2S 14x48 12x16 55 30/<32 12x16 55 30)4x35 }* 16x16 90 30)4x40 16x16 50 30)4x43 J* 16x16 50 30)4x48 16x16 55 30)4x511* 16x16 55 30)4x56 16x16 60 30)4x591* 20x20 55 36}*x35}* 20x20 55 36}*x40 20x20 60 36}*x431* 20x20 65 36}*x48 20x20 70 36}*x511* 20x20 70 36}*xS6 24x24 60 36}*x59}* 24x24 60 36}*x64 24x24 65 3614x671* 24x24 65 48)*x44 24x24 65 48)4x50 24x24 65 48)4x54 24x28 65 48)4x60 24x28 65 48)4x60 24x28 65 48)4x64 28x28 65 48)6x64 28x28 65 48)4x64 28x28 65 48)4x70 28x28 65 48)4x70 30x30 6S 48)4x70 30x30 65 48)4x74 30x30 65 48/x74 30x30 70 48)4x74 30x30 70 48)4x80 30x30 75 48)4x80 30x30 75 48)4x80 SERIES 26 " Height of Water Line........... --......... 47 " Height to Supply Outlets................ 58}*" Add to height for Trimmings--------- 11 " Add to length of Boiler for Smoke Box .................................................... 7X~ Width of Boiler.................. ............. ..... Width of Boiler includ. Trimmings 40 " Height from floor to Center of Re- turn Tappings................................... 20 " Height of Fire Box to Crown____ 22 " Height, Grate to Middle of Feed 16 " Size of Smoke Flue............................... 10 " STEAM 31 " 50 " 62/" 11 " .38 " 54- " 67yt~ 11 " 7/" S'4" 45 " 53 " 20/" 21 " 24 " 26 " 18 " 20 " 12 " 16 " 47 " 59 " 73 " 12 " 61 " 21}*" 26 " 20 " 20 " Size of Feed Door_......................... 9x17 9xL7 11x21 10x17 00 * WATER .26 " "31 "' 38 " 47 " 55 " 59 " 66 " 73 " 7}*" 7)4" 8/" 8)4" 36 " 42 " 48 " 59 " 20 " 20}*" 21 " 21}*" 22 " 24 " 26 " 26 " 16 " 18 " 20 " 20 " 10 " 12 " 16 " 20 " 9x17 9x17 11x21 10x17 Trimmings as listed below are sent with each Steam Boiler without extra charge. One 8-incb Economy Deegan Regulator with lever, weight, chains and pulleys. One Water Gauge complete with glass and brass rods. Two Brass Compression Cocks. One Steam Gauge with Pigtail Syphon. One Safety' Valve. Outlets for Safety Valves are tapped in accordance with the A. S. M. E. Code. No Trimmings are sent with Water Boilers. Fire Tools. With every Steam and Water Boiler there is sent free a Brush, Poker and iper. _ SPECIAL CATALOG WILL BE SENT ON APPLICATION 230 international Heater Co. Boilers InTERH/ITIOn/IL ECONOMY SECTIONAL BOILERS STEAM Member 35-19 4-19 45-19 5-19 4-26 45-26 5-26 55-26 6-26 5-31 55-31 6-31 65-31 7-31 75-31 8-31 85-31 5-38 55-38 6-38 65-38 7-38 75-38 8-38 85-38 9-38 95-38 10-38 105-38 11-38 Bating 700 825 975 1100 1000 1200 1300 1500 1600 1650 1900 2050 2300 2450 2700 2850 3100 2500 2800 3050 3350 3600 3900 4150 4450 4700 5000 5250 5550 5800 Coal Capacity Poinds 195 225 265 295 290 340 375 42S 460 480 545 590 645 70S 770 825 890 685 770 835 920 985 1070 1135 1220 1285 1370 1435 1S20 1585 Evaporative Power 9.6 9.6 9.6 9.6 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.3 9.7S 9.75 9.75 9.75 9.75 9.75 9.75 9.75 9.75 9.75 9.7S 9.75 9.75 Surface of Fnel Bed Inebes 19x20 19x24 19x28 19x32 26x24 26x28 26x32 26x36 26x40 31x32 31x36 31x40 31x44 31x48 31x52 31x56 31x60 38x32 38x36 38x40 38x44 38x48 38x52 38x56 38x60 38x64 38x68 38x72 38x76 38x80 Lenitb of Boiler inches 25}* 29 33}* 37 29 .33}* 37 41}* 45 37 41}* 45 49}* 53 57}* 61 65}* 37 41}* 45 49}* 53 57}* 61 65}* 69 73}* 77 81}* 85 Inside Din. of Ashpit Inches 22x24 22x27}* 22x32 22x35}* 25/x27}* 25*4x32 2S/x35>* 25*4x40 25/x43}* 30}*x35}* 30)4x40 30)4x43 }* 30)4x48 30)4x51}* 30)4x56 30)4x59}* 30)4x64 36}*x3S}* 36}*x40 36*4x43}* 36}*x48 36}*x5l}* 36}*x56 36}*x59}* 36}*x64 36}*x67}* 36}*x72 36}*x75}5 36*4x80 36*4x83}* TAPPIH6S** Seppiy_______Betarn 2-3" 2-3" 2-3" 2-3" 2-3}*" 2-3}*" 2-3}*" 2-3}*" 2-3}** 2-4" 2-4" 2-4" 2-4" 3-4" 3-4" 3-4" 3-4" 2-5" 2-5" 2-5" 2-5" 2-5" 2-5" 3-5" 3-S" 3-S" 3-5" 3-S" 3-5" 3-5" 2-3" 2-3" 2-3" 2-3" 2-3}*" 2-3}*" 2-3}*" 2-3}*" 2-3}*" 2-4" 2-4" 2-4" 2-4" 2-4" 2-4" 2-4" 2-4" 2-5" 2-5" 2-5" 2-5" 2-5" 2-5" 2-5" 2-5" 2-5" 2-5" 2*5" 2-5" 2-5" timber 6-47 65-47 7-47 75-47 8-47 85-47 B9-47 9-47 B95-47 95-47 B10-47 10-47 B105-47 105-47 Ratios 5300 5900 6300 6900 7300 7900 8300 8300 8900 8900 9300 9300 9900 9900 Surface of Evaporative Enel Bed Power_______ inches . 9.7 9.7 9.7 - 9.7 9.7 9.7 9.7 9.7 9.7 '9.7 9.7 9.7 9.7 9.7 47x50 47x55 47x60 47x65 47x70 47x75 47x70 47x80 47x70 47x8S 47x70 47x90 47x70 47x95 Length of Boiler Inches 54 59 64 69 74 79 84 * 84 89 89 94 94 99 99 Inside Dim. of Ashpit Inches 48/xS4 48)|x60 48)*x64 48)6x70 48)6x74 48)6x80 48)6x74 48/x84 48)6x74 48)6x90 48)6x74 48)6x94 48)6x74 48)6x100 TAPPINGS Seppiy Retvrn 2-6" 2-6" 2-6" 2-6" 3-6" 3-6" 3-6" 3-6" 3-6" 3-6" 3-6" 3-6" 3-6" 3-6" 2-6" 2-6" 2-6" 2-6" 2-6" 2-6" 2-6" 2-6" 2-6" 2-6" 2-6" 2-6" 2-6" 2-6" SERIES 19" Height of Water Line.......................................................... 44" Height to Supply Outlets................................................. 53" Add to height tor Trimmings.......................................... 9" Width of Boiler, including Trimmings................... -- 32" Add to length of Boiler for Smoke Box......... .......... 6" Height from floor to Center of Return Tappings.. 18" Height of Fire Box to Crown....... ................................ 22" Height, Grate to Middle of Feed Door...................... 16" Size of Smoke Flue.--........................................................ 9" Size of Feed Door.............................................................. 9x14" 26" 47" 56/" 11" 40" 7}*" 19" 22" 16" 10" 9x17" 31" 38" 47" 50" - 54" 59" 62%" 67X' 72}*" 11" 11" 12" 45" 53" 61" 7H" 8 w 19J4" 19/" 21}*" 24" 26" 26" 18" 20" 20" 12" 16" 20" 9x17" 11x21" (2) 10x17' Trimmings as listed below are sent with each Steam Boiler without extra charge. One 8-inch Economy Deegan Regulator with lever, weight, chains and pulleys. One Water Gauge complete with glass and brass rods. Two Brass Compression Cocks. One Steam Gauge with Pigtail Syphon. Sutlets^fdr Safety Valves are tapped in accordance with the A. S. M. E. Code. Sizes marked with a star as regularly shipped have a bridgewall limiting the grate to con venient length for hand firing. Full length grates are shipped only when specified on the order. The Economy Line of Boilers does not require any headers. Plug and bush flow and return openings to suit size of flow arid return mains. SPECIAL CATALOG. WILL BE SENT ON APPLICATION In addition to Boilers listed in this book we also manufacture a complete line of Round Steam and Hot Water Boilers and Hot Water Supply Boilers. 231