Document o9b3ZE7jmp7jpqgB2aJeqV6E7
592
CHAPTER 33
1946 Guide
Pointers on Selecting Equipment for Industrial Gas.Cleaning, by C. E. Miller (Chemi
cal and Metallurgical Engineering, 45, .March, 1938, p. 132-5)..
'
Electrical Precipitation, by W: A. Schmidt and E. Anderson (Electrical Engineering,
57, August, 1938, p. 332-338).
v
Electrostatic Precipitation for Cleaning Industrial Gases, by H. W. Wagner {Fuel Economist, 10, 1935, p. .895-9, 942-5, 971r3).
Dust Precipitation, by M. Pauthenier and Mme. Moreau-Hanot (Electrician, 113, August 10, 1934, p. 187-9).
Alternating Current Precipitators for Sanitary Air Analysis: II. Acid Formation in Electric-Precipitators, by W. G. Hazard and Tomoyoshi Ishikawa {Journal of Industrial } Hygiene, October, 1932, p. 367-70).
Electrical Precipitation, by A. W. Simon.'and L. C. Kron {Electrical Engineering, 51,
February, 1932, p. 93-5).
The Mathematical Theory of the Cottrell Electric Precipitator, by A. W. Simon {Iron and Steel Engineering, 6, 1929, p. l'43-6).
Progress in the Art of Electrical Precipitation Since 1900; by P. E. Landolt {Trans actions American Electrockem.rSociety, 51, 1927).
. Some Factors and Principles Involved in the Separation and. Collection of Dust, Mist and Fume from Gases, by Evald Anderson {Transactions American Institute of
Chemical Engineers, 16, 1924, Pt. 1, p. 69-86).
Electrical Precipitation of Solids from Smelter.Gases, by Ross B. Rathbun {Trans
actions American Institute of Electrical Engineers, 4l, 1922, p. 815).
Electrical Engineering Features of the Electrical Precipitation, Process, by G., H. Horne {Transactions American Institute of Electrical Engineers, 41\ 1922, p. 808). ;
CHAPTER 34 -AAutomatic (Control
Basic Types of Control, Types and Functions of Controllers, Designation of Temperature Control, Automatic Control Terminology, Residential Control Systems,. Control of Auto matic Fuel Burning Appliances, Zone Control, Control of Unit Systems, Control of Refrigeration Equipment, Application of
Control Devices to a Typical System
THE function of automatic control, as applied to the heating, venti lating and air conditioning industry, may be broadly subdivided into the maintenance of temperature, humidity, pressure, and liquid levels within predetermined ranges. It automatically coordinates the operation of the various controlled mechanisms in proper sequence to produce the desired result. A thermostat, for instance, is a controller responsive to temperature which initiates a force that repositions valves, dampers, etc., as required to maintain selected temperatures. Similarly, a hygrostat or humidistat is a controller responsive to relative humidity which initiates,
a force that repositions the controlled sources as required to maintain a selected relative humidity.
BASIC TYPES OF CONTROL
There are two basic types of controllers, (1) the two-position, on-off, or positive acting controller, which functions to move a valve, damper or electric switch through its full travel' (not necessarily 100 per cent) from' open to closed position and vice versa, and (2) the throttling, proportioning, or intermediate acting controller which functions to reposition the valve, damper, or other controlled device by small increments of its total travel as the controller senses a slight change in the controlled condition. The available equipment may be broadly sub-divided into three main groups,. (a) self-contained equipment, (b) electrically operated equipment, and (c) pneumatically operated equipment.
Seli-Contained Equipment
In self-contained controllers the primary source of power is the vapor pressure of an enclosed volatile liquid which varies with the temperature changes of the controller bulb. Such pressure changes are transmitted, directly into the bellows or diaphragm mechanism of the controlled . valve. Devices of this type produce gradual operation and are used to regulate the flow of heating and cooling media to coils, radiators, and liquid tanks. Each instrument is designed to operate within a pre determined selected temperature range and for a given condition. Care must be exercised to select a type which has the ability to withstand any. possible over-run, of temperature at the control bulb without damage to the instrument. Instruments of this type are available either with a rigid bulb or with a flexible tubing which connects the control bulb to the head of the instrument. This tubing is usually protected by a flexible metal, covering or armor and is available in varying lengths.
Electrically Operated Equipment
; Electrically operated equipment for either two position control or throt tling control is available in either low voltage or high voltage type. Low voltage equipment usually is designed to operate on 20 to 24 volt current. High voltage equipment may be used in connection with any of the
593
-