Document o9B3xDj3XrvKde1dpe3NepXz3

ETHYL CORPORATION RESEARCH LABORATORIES 1600 WEST EIGHT MILE ROAD FERNDALE 20 DETROIT, MICHIGAN J. B. Macauley R. K.Scales J. S. Wintringham Dr. Robert A. Xehoe College of Medicine University of Cincinnati Eden Avenue Cincinnati 19, Ohio September 2, 1948 Dear Dr. Xehoe; 1, Air Evaporation of Vitol Tie have completed an investigation of the air-evaporation character istics of Vitol fluid, as suggested at the meeting with the Thompson people in Cleveland on April 20, Our findings are sufficiently different from what we ex pected that I am transmitting our data to you no?/ in the form of this memorandum, rather than wait until the formal LTD report is issued. Furthermore, we were notified by Ivlr. Van iiartesveldt that you had given provisional approval to pro ceed with the Columbus program, and our information may have a bearing on that decision. You will recall that Dr. Roush of the Thompson Products reported pre liminary results indicating that the volatility of TEL in Vital was about onefourth that of TEL in gasoline. Our results indicate that a very different situa tion exists. Ae have evaporated samples of Vitol by introducing nitrogen through a sintered disc, so that near-equilibrium conditions exist. The effluent vapors, consisting of nitrogen, methanol, water and the components of the Antiknock Com pound were scrubbed through an iodine solution, and the scrubber solutions analyzed for lead. This procedure duplicates that used for TEL-heptane solutions as describ ed in our report LTD 46-47, a copy of v/hich you received at the time it was issued. T;ith gasoline, vie found that very little of the TEL evaporated until about 90^S of the fuel was evaporated. Consequently dangerous TEL concentrations in the air do not exist during most of the evaporative process, nor would the vapor space in a partly filled container contain high concentrations. On the other hand the re sidual liquid gasoline becomes, higher in TSL content. The data which we have obtained are presented in the following table and in the attached graphs. Under these conditions of evaporation, vapors from Vitol fluid will contain between 9000 and 12,500^stg. Pb/cu. ft. of air until essentially all the TEL has evaporated. An almost straight--line relationship exists between the amount of lead and Vitol evaporated--2% of the TEL for every 1% of the liquid. Calculations show that evaporation of pure TEL under similar conditions would pro duce a concentration of 130,000yUg. Pb/cu. ft. of air. The evaporation character istics of Vitol are, therefore, equivalent to those of^lO^o TEL solution. 0020661 Dr. Xehoe Sept. 2, 1948 2 AIR EVAPORATION OF VITOL FLUID MD "ETHYL" AVIATION GASOLINE Run .x Vitol Fraction, wt. % of samnle 53 30 10 7 Wt. % Evaporated, cumulative Fuel Lead 53 83 93 Res . 97.2 98.2 98.8 -- Concentration of lead in air, jig,/on, ft. 9500 ''' 200 30 - Concentration of TEL in residue ml.TEL/gal. 0.19 .26 .54 - 2 Vitol 5 5 5 11 74 5 10 15 26 Res. 11.8 21.4 35.2 61.2 - 12,500 12,400 13,000 12,100 - 2.82 ' 2.64 2.33 1.62 - CO CO 3 Vitol 4 Gasoline 6 11 10 73 0 40 40 10 5 3 6 17 27 Res . 0 40 80 90 95 93 10.7 32.0 49.8 - 0 (0.5) 2.1 5.4 13.0 35.5 9200 9200 9100 - 130 160 480 1250 3130 8540 2.58 2.25 - 4.5 7.45 22.0 42.5 78.5 145.0 Run 1. Vitol fluid, laboratory prepar:ation, no corrosion inhibitor. 3.03 ml. TSL/gal. Run 2. Vitol fluid, laboratory preparation, no corrosion inhibitor, 5.03 ml. TEL/gal. Run 3. Vitol fluid, commercial grade, 2.72 ml. TEL/gal. Run 4. Aviation gasoline, CRC-23R, 4.5 ml. TEL/gal., data from LTD 44-57. These results, striking as they may seem, are in qualitative agreement with the laws of physical chemistry: as systems approach immiscibilifcy the partial pressures of their components increase considerably and approach the vapor pressures of the pure compounds, a state which is reached when the components become immiscible The experiments which we conducted were not designed to duplicate the surface evaporation experienced in a liquid spill, but with this reservation in mind, the following picture of the relative effects of Vitol and leaded gasoline spills can be drawn. In the first place, the evaporation of Vitol will, from the start, introduce considerably greater quantities of TEL into the atmosphere, build ing up the TEL concentration much faster than is the case with gasoline. In a confined space a real hazard will exist. For example, (1) if one gallon of Vitol is allowed to evaporate to the 50/ polnu, either as the result of a spill or from storage in an open container, into a room of 1000 ou. ft., 2.9 g. ,of Pb will be introduced into the atmosphere, or 2,900yg.Pb/cu.ft. On the other hand, under the same circumstances, there would be only 0.048 g. Pb, or 48//H,g.Pb/cu. ft. re sulting from evaporationof a similar quantity.of aviation gasoline. These figures KE 0020662 ,r- - t - 1 : k, t r ; Dr. a shoe Sspt. 2, 1S48 3. are 31 and 0.5 times, respectively, the maximum allowable concentration for 20minute exposure. (2) The heel remaining in a storage tank containing Vitol or gasoline furnishes another interesting comparison. With,Vitol we can expect about 10,000 /Ug.Pb/cu. ft. of vapor space in the tank, no matter what the size of the heel in relation to the tank. With gasoline even if 80% of the heel evaporat ed into the vapor space, there would be less than 500 /ag.Fb/cu. ft. in the tank atmosphere, and to bring about this condition the liquid hold-up in the tank would have to be on the order of 0,2% of the tank volume, or sai' 20 gal. in a 10,000-gal. tank which would be unusually low. (3) Still another condition, which may exist in practice, is the build-up of a high lead (TEL) concentration under the semienclosed hood of an automobile from the, evaporation of Vitol from the storage cannister. A mechanic might be subjected to a high concentration very readily from this source. On the other side of the picture, our experiments shov? that evaporation of Vitol is a very efficient means of eliminating TSL from the residue, the opposite picture from what occurs in the case of gasoline. Incidentally, we have satisfied ourselves that although the water content of the residual fluid increases, the T3L is removed sufficiently rapidly that no separation occurs due to evaporation. If water Is added, however, such as in washing for Instance, TEL will, of course, separate immediately. Thus, from certain standpoints Vitol presents more of a hazard than gaso line, and from others less. Certainly idle situation is different, be will be very Interested in learning your reaction to these results, and what recommendations you will make concerning the storage, handling and use of this product based on these observations. 2. Further Work The results recorded above have seemed sufficiently provocative to warrant further work. We plan to carry out the following program, to be completed in about two months : 1) Determine evaporation characteristics of Vitol fluid contain/: 0% and 5% water. If we are at present dealing with borderline immiscibility, these experi ments should point it out, 2) Determine accurately the partition function of TSL between the alcoholwater and dispersed inhibitor phases. Preliminary experiments indicate the inhibitor contains appreciable, perhaps dangerous, concentrations of TEL. 3) Determine the separability of the inhibitor phase. Although Thomson Insists the emulsion is permanent, we are still skeptical. We have observed ag glomeration of inhibitor droplets, separation on centrifuging and a concentration gradient in commercial Vitol. In view of (2) above, this point needs clarification. We shall keep you advised of our progress, and send you a copy of our finished report on the work to date. We would be interested in the results of your toxicity' studies and in learning the details of your recommendation to Thompson. KE 0020G63 i ;o i" liii.o ; vA' .i:' - Rg 0020664 if: 2 - Concentration of 1'SL in ino'v^pornfod Portion of vivo! fluid. ; i O lyia 1 Laboratory Vifcol O Fun 2 - Laboratory Vitol ,1 f:'.m 3 I've: r ;; >'; Prof,. Titol \t \ v \A ' xftorrpson r'.vod,. Vi'rol 0\ \ \\ X \ \ \*, \ \ \ l \ t ) ! | Y ~i /\ \ Laboratory fitoi / SO LG SO 00 Height of Vitoi. ovarioratett K 0020665 1O0 ^OC.COO 1C, OCX) Sin i Laboratory Vito'l Sura 3 - Thompson Vitol 1,COO - 00 - .Loaded gasoline LID 14-67 fi 1 M icrograas le a d p e r ou,, rs * o f 10 Toxic limit 4 mcrogrurns/cu, ft. 1 20 40 60 80 Weight por cent evaporated " Comparison of Load in Air for Evaporation of Vital Fluid and Leaded Gasoline. IOC yC 0020666 ; - - ____ _ * - `