Document o3QmE9VoV96EaEddv9ommqjR
nimm US BOILERS
EMPIRE AND STANDARD
TYPES 1-C-E AND 1-G
FOR STEAM AND HOT WATER
PLAINTIFF'S EXHIBIT ASI-II72
American q <taitdaffd Radiator ^ Maintain}
CORPORATION
12860
EMPIRE ini milUl m (OILERS
FOR EFFICIENCY AND BEAUTY
If you seek both beauty and efficiency, the Empire Gas Boiler (see front cover) is perfect. Its rich, colorful Jacket is finished in Canyon Two-Tone Red, suede texture. It is so handsome and beautiful it blends with the finest modern basement and appointments. All controls are concealed beneath the smart exterior, out of sight, out of the way, but available in an instant when necessary.
STANDARD BOILER TYRE 1-0
WHERE APPEARANCE IS SECONDARY
If you have a separate boiler room, or if appearances are unimportant the Standard Gas Boiler (see illustration above) will fill all requirements. For it is identical with the Empire except it does not include the all-over Canyon Two-Tone Red Jacket, and the controls are on the outside of the boiler.
Look (or this Distinctive Name Plata
SCIENTIFIC DESIGN
American Gas Boilers have been designed by Gas heating experts. They embody the latest developments in the field. Specially designed for Gas operation only they get all the good out of every cubic foot of gas. Safe, sure and silent in operation they are designed for a lifetime of trouble-free, economical service.
THERMOTOR THROTTLING VALVE
This special Valve is controlled by the thermostat. It gradually reduces or increases gas flow to the burner to keep room temperature just right. It keeps gas consump tion to a minimum, and combined with the thermostat eliminates the need for manual work to keep constant comfort in the house.
CAREFREE COMFORT
Both the Empire and Standard Gas Boilers offer you heating that's so automatic you don't even have to order fuel! Tlie thermostat, the special Thermotor Throttling Valve and other quality controls guard the temperature you want with precision accuracy. Clean, quiet and odorless in operation, these Boilers have brought the blessin'- of automatic heating comfort to thousands of homes - e won the lasting approval of homeowners.
HEAVY INSULATION
A thick layer of Air-Cell Asbestos Insulation prevents excess'heat loss into the basement. This also aids in re ducing operating costs and keeps the jacket cooler.
EASY TIME PAYMENTS
If you are modernizing, it is not necessary to pay for a new Empire or Standard Gas Boiler all at once. Easy time pay ments can be quickly and simply arranged. They can be planned so that monthly payments will be fully in accord with your budget -- no matter how big or small.
SHORT FORM SPECIFICATIONS
(Far All Boilers)
In general the following form will be found adequate: "Furnish and install according to manufacturer's instruc tions, where shown on the plans a Type 1-G-? American Standard (or Empire) Steam (or Water) Gas Boiler with an A.G.A. output rating of......... sq. ft. of radiation. The boiler shall be manufactured by the American Radiator & Standard Sanitary Corporation and shall be completely equipped with Type 10-MT Equipment consisting of . .. (list items of equipment as indicated on opposite page)
This may be supplemented with paragraphs governing installation of gas supply, piping, connections, tests, etc., as required.
12861
EMPIRE BOILER CONSTRUCTION FEATURES
1. Jacket--handsomely finished in new Canyoo Two-Tone Red -- suede finish.
2. Steam Flow -- a correctly and specially designed steam supply line pipe fitting.
3. Trick Asbestos Air-Cell Insulation effectively prevents excess heal loss from boiler.
A. Low Water Cut-Oft-- on steam boiler ooly. Completely shuts off gas supply to mnin burners if water line reaches a low point.
5. Thermotor Throttling Valve -- operated from the room thermostat. Completely shuts off supply of gas to main burners when desired room temperature has been obtained. All con trol functions centered ioooe valve. A throttling valve cmbodyiog mechanical limit control.
6. Steam Pressure or Water Temperature Regulation--controls supply of gas In burners according to predetermined steam pressure or water temperature.
7. Gas Supply Line -- ample size, (termite unrestricted supply of gas. Gas Pressure Gov ernor included, mounted outside jacket at rear.
8. Burner Cock -- specially designed to permit smooth flow of gas with minimum friction.
9. Thermostatic Pilot -- protected from moisture or dirt. Keeps gas supply vnl\c closed unless pilot is burning.
18 17
Cuiatvay View
10. Quiet Burners -- raised drilled ports. Rliie flame burner. Quiet in operation.
11. Clean-Out Opening -- provides easy ac cess for cleaning flue surfaces of sections.
16 12. Water Column -- on steam boilers only
Artistically framed within jacket giving pro-
15 loclion against breakage and adding to the
tveauty of the gas boiler.
14 13. Metal-to-Metal Joint -- ground, gas
light. No cement or putty used. Patented pio
13 typ cast iron section. The most effective type
of cast iron heat-absorbing surface. Rapidly aod efficiently absorbs the heat from the rising 12 columns of hot gases, transferring hcnl ( water within boiler.
I I. Compound Pressure ano Vai i tm (Jm i.t -- mi steam boiler On water hoiler. combi nalimi Hltitudc gauge and ihcrmomcler loco led here
K) 15. Distinctive Name Plate--"AMER
ICAN'*, the best known name in heating.
0 16. Pop Safety Val'f.-- A. S. M. L. stand ard. Fully enclosed io jacket.
Q 17. Draft lloon -- fully enclosed. Acid-proof vitreous enamel on ARMCO iron. Prevents either excessive drafts or down-drafts from affecting proper combustion.
18. Canopy -- acid-proof vitreous enamel on A R MCO iron set in putty-filled groove forming gas-light joiot.
STANDARD BOILER CONSTRUCTION FEATURES
t. Canopy--acid-proof vitreous enamel on ARMCO iron, set io putty-filled groove. form ing perfect gas-tight joiot.
2. Compound Pressure and Vacuum Gauge -- Steam: On water boiler, combination alti tude gauge and thermometer located here.
3 Steam Connection -- leads from steam domo of boiler to diaphragm of main throttling valve
.4 Resetting Low Water Cut-Off -- com
pletely shuts off supply of gas to main burners if the water lioe on steam boiler reaches a low point.
5. Gas Valve -- electrically operated from room thermostat. Steam Pressure or Water Temperature throttles gaa flow to maintain required conditions. Upper limit and manual control also embodied io same valve.
6. Gas Pressure Governor -- maintains gas pressure at a fixed maximum.
7. Gas Supply Line -- ample size, provides unrestricted supply of gas.
8. Steam Diaphragm--steam from dome actuates diaphragm, throtllins gas when de sired steam pressure is reached. On water boilers, we furnish at this point an accurate water temperature coolrol device which is readily adjustable aod similarly throttles the gas flow when the water in the boiler reaches the desired temperature.
9. Quiet Burners -- raised drilled ports. Blue flame, atmospheric type, quiet in o|*rrstion.
Cutaway View
lt>. Thermostatic Pilot - Oiieraie*thermotor valve mechanically, keepiog this valve rinsed iiiilena pilot is burniog properly.
Jl Venturi Mixer Tube - induces proper velocity to gas and primary air. and obtains l he correct mixture nt gas and air.
12. Rurner Cock socially designed to permit smooth flow of gas with minimum friction.
13. Jacket Insulation - heavy asbestos sircell effectively prevents excess heat loss from boiler.
14. Jacket- baked enamel on |x>th side* Black enamel trimmings.
15. CleanoutOpeninc -- provides easy seres* for cleaniag flue surfaces of sections.
16. Patented Pintypk Cast Iron Section - the most effective type of cast iron heal-ahsorhing surface. Rapidly and efficiently absorbs the. heat from the rising columns of not gases, and transfers this heat to the water within
17. Metal-to-Metal Joint -- ground, gastight. No cement or putty used.
18. Pop Safety Valve -- A.S M R. standard
19. Draft IIooo -- uciil-proof vitreous enamel on ARMCO iron. Prevents either excessive drafts or down-drafts from affecting pro|er combustion.
"10-MT" EQUIPMENT INCLUDES THE FOLLOWING. STEAM. rhermotor 1 hrotlling Valve with Thermo-Pilot (566-VS). Steam Pressure Regulator . Resetting Low Wntcr f .ul-Off (62U). Gas PrcHSurcIGoverimr. ('.oni pound
Steam Gauge; Pop Safely Valve; Boiler Drain and Pilot Cock: Insulated Enameled jacket. Vitreous Enameled Draft Diverter.
WATER: thermotor throttling Valve with Thermo-Pilot (S66-VW); Water Temperature Kegululor, Gas Pressure Governor, Cnmhiiiahnn Altitude Gauge and Ther mometer; Boiler Drain and Pitot Cock9. Insulated Enameled Jacket; Vitreous Enameled Draft Diverter
Note I he 566-V Thermotor Valve wi th l nmiforiner is electrically o[>cruted by room tliermionUiI. Fur use w il li uuy 2-wire Thermostat or any .t-wire. Series Ml. I herne'slal t with or without clock) for automatic room tc/nperulurc regulation The 556-V also includes Thermo-Pilot, throttling and mechanical upjvcr limit control.
12862
RATINGS AND DIMENSIONS - STEAM AND WATER
EMPIRE BOILER TYPE 1-G-E
GAS INLET
" 3J4iJ
! 4,,4 :
Holler No
Steam
| Hating 1
1 S<1 Ki.
-
I-G- 4-E l-G- 5-E l-G- 6-E I-G- 7-F. 1
610
77
940 1105
l-G- 8-E l-G- 9-E 1-G-10-E
1270
1435 ! looo
1
Supplies Installed Mediation Sq H
400 513 627 743
859 978 1097
'!
Hating i Sq Ft
OHO
1240 . 1500 i 1770
j; 2030 l: 2300 ;! 2560
:
Suppli s Installed
Sq. Fl. i Sq. Fl
130 200
Hlu
Hlu
6 43
H20 looo lion
j
!
482 015 750
893
1373 | 1030
1567
1175
1733 1 1316
1 Ham. Rue
1 a* Conn.
Number A' Sijtr Tapping
-------- ----
Finn
Return
:12 18 36
20 40
22 44
ft
a 8
X : 2-4 ix 1 ix ! 2-4 1 J^2 ! 2-4
2-4 2-4 2-4 2-4
24 48
8
14 2-4
2-4
26 52
0
2 ' 2-4
2-4
28 56 0 2 2-4 2-4
STANDARD BOILER TYPE I-G
Hoilcr No
| ij
Steam Ruling Sq. ft.
1 !
Supplies Installed Radiation S<|. Ft.
A l A.
j \\ nler j| Hating J Si,. Ft
-Supplies Installed .. . -- ----- -----
Sq Ft
t:o
Hlu
Sq. Ft. Hlu.
II <! '
| 1) I Ga*
I
'
Number A Size Tapping
l-G- 4 l-G- 5 l-G- 6 l-G- 7
610 775 940 1105
400 513 627 743
i 980
|! 1210
\ 1500
i 1770
613
820 1000 MOO
482
10 35 >o'A ! 6
IX 2-4
615 23 39 53
7 IX 2-4
750 27 43 53 H 1 8 IX 2-4
803 31 47 51
8 ix 2-4
2-4 2-4 2-4 2-4
l-G- 8 l-G- 9 l-G-10 I-G-II
1270 1435 1600
1765
839 978 1097 1217
j 2030 |. 2300 li 2560 1 2820
1373
1567
1755
1013
1030 1175 1316 1 459
35 51 55
8
39 35 56
0
43 59 58 J4
9
47 63 50
10
14 2-4 ey 2-4
2-4 2 2-4
2-4
2-4
2-4
2-1
* Hillings listed under "Supplies IiihIqIIimI" include h stiilidde nllmvnnee for normal piping and pickup. This rating is timwn computed on Ihn hast* nf ISO litii. Mini 200 Hlu ix*r square foot per linur cuiixmihi for w a ter I Killers ;nni J HI lllu jkt square fool ,mt hour for steam boilers Noln: All diniciiainns arc in inches.
* For Hlniin Imiler Water boiler is \" shorter.
Form \ 7020 *SM H Graphir
American ^ ^taudavd Radiator ^^aititai^
c)7ewcy<k CORPORATION ^PiUiiwujh
12863
printed mi H S A.