Document npgL3ma19y8K44zL4M4wXR98z

FES $ 545.00 EXPENSES 13*50 TOTAL i 558.50 Billed - _FIR_ST VISIT June 157, 19* 64 LAST VISIT June 30, 1964 NO. OP VISITS CHARGEABLE_____ -!_________ ^ njjb $r%r,, Charles H. Hudson Anmfa* \ ., rvtaM la Q4.A. Surreyor EXX-MOR-005803 American Surratt nf Shipping 45 BROAD STREET, NEW YORK, N. Y. -10004 Report Ho. NH5539 Newport Hews, Va., June 30, 1964 g/s "B330 BOSTON" ISIS IS TO CEETIFI that the undersigned Surveyor to this Bureau did, at the request of the Owner's Representative, attend the steel screw s/s "ESSO BOSTON", Official NUnber 283,784 of Wilmington, Delaware on Jtuie 19, 19ok and subsequent dates as vessel lay afloat and on drydock at Newport Revs Shipbuilding and Dry Dock Company, Newport News, Virginia In order to examine and report upon the vessel relative to Drydocking, Installation of Bulbous Bow, Annual Boiler Survey, Coanencemesb of Special Survey Nb. 1 on Bull and Commencement of Special Survey on Machinery and has to report as follows: SHTDOCKIBG 1* 3Sm vessel was placed on dxydock and the sterafme, keel and shell plating cleaned, examined and placed In satisfactory condition* (a) Scattered slightly leaking shall rivets and caulking edges of riveted seams were caulked and mads tight. Bilge keel rivets caulked sad made tight -as necessary and where fractured In way of welded increments, chipped out and revelded. (b) Shall piling from light load Una to rail was sandblasted and entire outside surfaces recoated* 2* Outstanding racamnendatlon of Boston report number B25L96 dated November 17, 1963 was not dealt with at this time and remains outstanding. 3* The rudder was examined and found satisfactory* 4* Overboard discharge and suction openings In shall plating were examined and found satisfactory. 9* Strainers were removed from sea cheats and cleaned and recoated together with chests. Sea valves opened, cleaned, overhauled, ground In or machined and reseated aa required, examined, repacked and placed In satisfactory condition by minor repairs. 6. Bow and stern anchors and sables were ranged, cleaned, examined and found satisfactory. 7. Tbe propeller, 4 blade solid bronze, was examined and found satisfactory. 8. Clearance in oil lubricated stem bearing was checked and found to be .030". TieaffATJATTON eg NSW BUIB0Q5 BCW 9* The awtating bow pi rig and framing was cut away in an arc extending from the ffWlrfliP*1 m Tbit Report 1a limed subject to the condition that it la understood end ecreod that neither the Boren* nor any of lta Committees is under any elreumstenees whatever to be held responsible for any Inaccuracy tn any report or certificate Issued by this Bureau or its Surveyors or in any entry m the Record or other pnMIimti"1 of the Bureau or for any error of Judement. default or nccUrenee of its Officers. Surveyors or Asents. Printed In O.SJL EXX-MOR-005804 BAGS 2 Report go. HH5539 afa "wbcq yypQB* Item number 9 continued - 37*-8" water lino at stem. to frame $ 136 1/2 at keel and removed in its entirety. A new previously prefabricated bulbous bow of all welded const ruction was fitted and welded in place as a unit. Bow consisting of plating, fawning, floors, stringers, breasthoaka, swash bulkhead and all other internal members was built in accordance with approved drawings as fallows: Newport Sews Shipbuilding and Dry Dock Co. drawings - Bo. 226413, Shell Elating in way of Bulbous Bow and Bo. 226411, Bow Framing in way of Bulbous Bow, approved April 15* 1964. Bow examined daring construction and after installation and found satisfactory. Upon completion of work, fore peak tank tested hydrostatically, and found tight. CttigBCBaKg eg SPBCTAL SCOTS! BO. 1 - HOLE, 10. Boo fore peak tank was examined Internally, tested hydrostatically and found satisfactory. 11. Machinery spaces and forecastle spaces were examined internally and found satisfactory. 12. Backs were examined Including deck composition where fitted and found satisfactory. 13V Masts, rigging, hawse pipes and equipment were examined and found satisfactory. 14. Special Survey Bo. 1 on Bull is not complete. CCMflBKgMHB? CP SPECIAL SOBBT - MACHCTgBT 15V The main 3.P. turbine was opened, all parts examined, clearances checked and all found satisfactory. The 3.P. rotor was removed to shop, fly ashed, dynamically balanced and journals polished. Botor reinstalled satisfactorily in vessel. The flexible coupling was opened, cleaned, examined, and found satisfactory. 16. The main L.P. turbine flexible coup! ing was opened, cleaned, examined, found satisfactory >--< ngfatii a . 1J. The main turbine ahead throttle valve was opened, examined and placed in satisfactory condition. A new valve seat with stellite face was fabricated, seal welded la position and disc lapped in. Valve closed tqp with new gaskets. lB. The Bo. 1 main feed pump was opened, steam and liquid ends examined, overhauled under the avqyervialaa of the manufacturers' representative and found in satis factory condition. 19. The deaerating feed water tank was opened, cleaned, einmriimd and found satisfactory. 20. Item # 5 of this report may be credited to this survey. 2L. Special Survey on Machinery is not complete. ahhual Bonaa auKvig 22. The two "i" watertube boilers together with their superheaters were opened, 0CBTlHUg> - EXX-MOR-005805 BAGS 3 Report Ho. HM5539 S/3 "RSSO B08I0H" Item number 22 continued - cleaned, examined externally and internally, including water sides, tested bydrostatically including main steam lines and found in satisfactory condition* Brickwork and refractory part renewed and pointed up as necessary* 23* Main mountings of both boilers vere opened, overhauled, ground in or machined and reseated as required, examined, repacked and found satisfactory. 24. On completion of repairs, drum safety valves and superheater relief valves vere set and floated under steam to allowed working pressure. 25* In the opinion of the undersigned, the vessel is considered year of grace in which to complete the Special Survey. for the 26* Vessel undocked June 26, 1964* Sgfflftlg 27* Orydocked 6-64 Annual Boiler Survey complete 6-64 Specie! Survey JL on Hull ccnmenced 6-64 Special Survey on Machinery commended 6-64 It is recommended that vessel be retained in present class with this Bureau. 0OT3BLHPIH0: Item #2 EXX-MOR-005806 Ammran ur?au of pipping 45 BROAD STREET. NEW YORK, N. Y.-10004 Report 3b, 355539 a/s "TM-qn nnsrow" Newport Seva, Va, June 3D, 1964. THIS IS TO CERTIFY that the undersigned. Surveyor to this Bureau did, at the request of the Owner's Representative, attend, the steel screw s/s "ESSO BOSTON", Official NUnber 283,73b Wilmington, Delaware an June 19, 196* and subsequent dates as vessel lay afloat azxd on drydodc at Newport Sews Shipbuilding and Dry Dock Coqpaxy, Newport News, Virginia In order to examine and report upon the vessel relative to Diydocklng, Installation of Bulbous Bow, Annual Boiler Survey, Caoeencemeot of .qpAM*iL Survey So* 1 on Hull and Comaenceaent of Special Survey on Machinery and has to report as follows] DHTDOCgDB 1* The vessel was placed on dxydock and the stersfraae, heel and shall plating cleaned, examined and placed in satisfactory condition* (a) Scattered slightly leaking shell rivets and caulking adgaa of riveted seams were caulked and made tight. Bilge keel rivets caulked and made tight as necessary and where fractured la way of welded increments, chipped out and revelded. (b) Shall plating from light load line to rail wan sandblasted and entire outside surfaces recoated. 2. Outstanding zeccnnendatlan of Boston report amber B25L96 dated November 17, 1963 was not dealt with at this time and remains outstanding. 3* The rudder was examined and found satisfactory. k Overboard discharge and auction openings in shell plating were examined and found satisfactory. 5* Strainers were mowed from eea chests and cleaned and recosted together with chests. Sea valves opened, cleaned, overhauled, ground in or machined and reseated as required, examined, repacked and placed In satisfactory condition by minor repairs. 6* Bow and stern anchors and cables were ranged, cleaned, examined and found satisfactory. 7* Tha propeller, 4 blade solid bronze, was examined and found satisfactory. 8* GLearance In oil lubricated stern bearing was checked and found to be .030"* TTgwmr.TATTQH OP BBf BUIB0CJ3 BOW 9* The existing bow and framing was cut sway in an arc extending from the UOId'JjSVMiV TUi Report is lssood mtlset to tht condition tost it is understood and screed tint noitlnr tin Bnmu nor aay of Its Committees Is under any circumstances whatever to be held responsible for any inaccuracy In any report or certificate issued by this Bureau or its Surveyors or in any entry la the Record or other publication of the Bureau or for any error of Judgment. default or negligence of its Officers, Surveyors or Agents. Printed is TJ.BJL - EXX-MOR-005807 PAGE 2 Report Bo. HH5539 s/s "esso Itsm number 9 continued - 37*-3" water Use at stem to frazae # 136 l/S at keel and teamed In Its entirety. A new previously prefabricated bulbous bow of all welded const ruction was fitted and welded in place as a unit. Bear consisting of plating, framing, floors, stringers, breastbooics, swash bulkhead and all other Internal aombers was built in accordance with approved drawings as follows: Seaport Sews Shipbuilding and Dry Dock Co. drawings - So. 22&L3, Shell Plating In way of Bulbous Bow and Do. 226fcU, Bow Framing In way of '^Hxtub Bow, approved April 15, 19&. Bow examined during construction and after Installation and found satisfactory. Upon completion of work, fore peak tank tested hydrostatically, THnrtw^ and found tight. (XMasmuaHgHg CP SPBCIAL SUBVar no. 1 - SOU. 10. She fore peek tank was examined internally, tested hydrostatically and found satisfactory. 11. Machinery spaces and forecastle spaces were examined Internally and found satisfactory. 12. Decks were examined including deck composition where fitted and found satisfactory. 13. Meats, rigging, hawse pipes and equipment were ** end found satisfactory. lfr* Special Survey 50. 1 an Hull is not complete. cnwcsacaffigg eg spbcial sparer - Mugnatg 15* 9m main H.P. turbine was openad, all parts examined, clearances checked and all found satisfactory. 9ui H.P. rotor was removed to shop, fly ashed, dynamically balanced and journals polished. Rotor reinstalled satisfactorily la vessel. 9*e flexible coupling was opened, cleaned, examined, and found satisfactory. 16. 9ze main L.F. turbine flexible coupling was opened, cleaned, examined, found astiisfm^tory ***** minatan^. 17* 9 main turbine ahead throttle valve was opened, examined and placed in satisfactory condition. A new valve seat with stellite face was fabricated, seal welded In poaitlon and disc lapped in. Valve doeed up with new gaskets. lB. The lb. 1 main feed pump was opened, steam and ilqpid ends examined, overhauled under the supervision of the aanufseturers* representative and found In satis factory condition. 19. 9ie deaerating feed water tank waa opened, cleaned, examined and found satisfactory. 2D. Item # 5 of this report may be credited to this survey. 2L. Special Survey on Machinery is not complete. AHHOAL BOUgR SUHVBf 22. Die two watertube boilers together with their superheaters were opened, cxariaujro - EXX-MOR-005808 BAGS 3 Report So. KS5539 Item number 22 continued - s/s "bsso Boarcs" cleaned, examined externally and internally, including water sides, tested hydrostatically "*; main steam lines and found in satisfactory cozriition. Brickwork and refractory part renewed and pointed up aa necessary. 23. Main mountings of 'both, boilers vara opened, overhauled, ground in or machined and reseated aa required, examined, repacked and found satisfactory. 2k. On completion at repairs, draa safety valves and superiieater relief valves vere set and floated under steam to allowed working pressure* 25* Id the opinion of the undersigned, the vessel is considered eligible for the year of grace in which to conplste the Special Survey. 26. Teasel undocked JUne 26, 1964. SOOftHg 27* Srydocked 6-64 Annual Boiler Survey complete 6-64 Special Survey on Bull coswenced 6-64 Special Survey on Machinery commanded 6-64 It is reccmnended that vessel he retained in present class with this Bureau. OOEBUBHHGs Item #2 EXX-MOR-005809 Mivit bURtAU OF 5 UPPlTsIG ' REPORT NO. NN5253 NO. IN RECORD 3936 OFFICIAL NO. ____ 283784 SURVEY REPORT// NAME OF VESSEL S/S "ESSO BOSTON" OWNERS Humble Oil & Refinincr Co PORT OF SURVEY Newport News PORT OF REGISTRY Wilmington, pe GROSS TONNAGE 30680 HULL BUILT BY Newport News S. B . & D. D. Co ~ HULL NO. 541 DATE 11 , Tqfin CLASS IN FULL SU fAMS DESCRIPTION OF SURVEY /J > - GROUNDING DAMAGE SURVEY AND REPAIRS - \ invoice no. NN7 2 5 0 DATE 12-3-63 TOi Humble Oil & Refining Co Marine Department P. 0. Box 1512 Houston 1, Texas ATTENDING: Mr. F. Newton - Rep. Owners Mr. T. Hushion - rt U.S.C.G. Mr. P. Bannister rt -U.S.C.S. FEES CHARGED SS (HJ DD AS SE ALL SS (RMO CONT. (RMO SS (M) TS CONVERSION SR RLL INT (RMO WT APPROXIMATE COST OF REPAIRS $26,000. FOR ENTRIES BY REPORT DEPT. ONLY SS BS ACG OCG DAMAGE $200. SEMI-AN (RMO OTHER TANK VESSEL CARGO: REPORT DtSTRIBUnONi OWNERS/AGENTS 6 ABS NEW YORK 2 COPY (IF ANY) /f w EXX-MOR-005810 Ammratt lureau nf pipping 45 BROAD STREET. NEW YORK 4, N. Y. Report No. NN5253 Newport News, Va. Nov. 26, 1963 S/S "ESSO BOSTON" THIS IS TO CERTIFY that the undersigned Surveyor to this Bureau did, at the request of the Owner's Representative, attend the steel screw S/S "ESSO BOSTON", Official Number 283,784 of Wilmington, Del. on November 25, 1963 and subsequent date as vessel lay on dry dock at Newport News Shipbuilding and Dry Deck Co., Newport News, Ya. In order to examine and report upon damage alleged to have been sustained when vessel grounded In the Southwest Pass, Mississippi River, November 10, 1963 while enroute from Baton Rouge, La* to Everett, Mass. In laden condition. For further particulars see log book and r eport as follows - UPON EXAMINATION FOOND; BOTTOM SHELL PLATING - PORT 1. Approximately 460 rivets and 325 linear feet of seam and riveted bilge keel started and leaking. RECOMMENDED: Rivets and seam to be caulked and/or welded as necessary to make tight. 2. Bilge keel distorted and approximately 60 linear feet of welded attachment fractured. Damaged bilge keel to be faired or cropped off. Fractured weld ing to be chipped out and rewelded. BOTTOM SHELL PLATING- STARBOARD 17 Approximately 175 rivets and 333 linear feet of seam and riveted bilge keel started and leaking. Rivets and seam to be caulked and/or welded as necessary to make tight. 4. Bilge keel distorted and approximately 57 linear feet of welded attachment fractured. Damaged bilge keel to be faired or cropped off. Fractured welding to be chipped out and rewelded. RODDER 5. Pintle Inspection plate, port side of rudder, missing. To be renewed. PROPELLER 6. Tips of 4 blades of solid bronze propeller slightly bent and nicked. Blade tips to be heated, faired, and dressed smooth. IAILSHAFT AND STERN BEARING 7. Oil lubricated stem bearing reported to be leaking and losing oil. Stem bearing to be tested with head of oil to determine source of leakage if possible. CONTINUED^* * li Issued rabjeet to Uw condition tht It la ondentood ond wood that neither tht Bureau nor any of lti Commlttooc Is trader any elretxmataneoa whatever to ba bald raaoonsttte (or any Inaccuracy tn any ronort or oartlfleato loaned by thla Bureau or Its Surveyors or in any entry to the Record or other nobUeatton of the Bnraan or (or any error of Indsment. default or nscllmnea ot Its OWesrs. Surveyors or Asvnta. Printed to U.BJL EXX-MOR-005811 Report No. NN5253 -2- S/S "ESSO BOSTONw 8. Bearing tight under head test. Tailshaft to be disconnected and drawn in for examination includ ing magnetic particle test. Inner and outer bearing seals to be removed for examination and bear ings examined. 9. Tailshaft satisfactory. Outer bearing seal found fractured in several locations with evidence of some overheating in way of inner lip. Some foreign matter present in seal and bearing. Condition of inner seal suspect. Inner and outer bearing seals to be renewed. Bearings to be cleaned* Tailshaft to be rein stalled and all connected as before. Assembly to be tested and proven tight. Propeller to be wedged on, nut driven up and void spaces filled with rust inhibitor. MAIN CONDENSER 10. Condenser subjected to fouling by mud and foreign matter during ground ing. .11 .12 To be opened, examined, cleaned and tested as necessary to prove satisfactory. Necessary removals and replace ments to effect repairs. Necessary staging. 13. New and disturbed work to be coated as before. 14 Necessary dry docking. The foregoing recommendations were satisfactorily carried out at this time and it is further recommended that vessel be retained in present class with this Bureau, being on November 26, 1963 in the opinion of the undersigned in seaworthy condition. Charles R. Hudson - Surveyor. EXX-MOR-005812 Atnmran lureau of pipping 45 BROAD STREET. NEW YORK 4, N. Y. Report No. NN5253 Newport News, Va. Nov. 26, 1963 3/S "ESSO BOSTON" THIS IS TO CERTIFY that the undersigned Surveyor to this Bureau did, at the request of the Owner's Representative, attend the steel screw S/S "ESSO BOSTON", Official Number 283,784 of Wilmington, Del. on November 25, 1963 and subsequent date as vessel lay an dry dock at Newport News Shipbuilding and Dry Dock Co., Newport News, Va. in order to examine and report upon damage alleged to have been sustained when vessel grounded in the Southwest Pass, Mississippi River, November 10, 1963 while enroute frost Baton Rouge, La. to Everett, Mass, in laden condition. For further particulars see log book and report as follows - UPON EXAMINATION FOUND: BOTTOM SHELL PLATING - PORT 1. Approximately 460 rivets and 325 linear feet of seam and riveted bilge keel started and leaking. RECOMMENDED: Rivets and seam to be caulked and/or welded as necessary to make tight. 2. Bilge keel distorted and approximately 60 linear feet of welded attachment fractured. Damaged bilge keel to be faired or cropped off. Fractured weld ing to be chipped out and rewelded. BOTTOM SHELL PLATING- STARBOARD Tl Approximately 175 rivets and 333 linear feet of seam and riveted bilge keel started and leaking. Rivets and seam to be caulked and/or welded as necessary to make tight. 4. Bilge keel distorted and approximately 57 linear feet of welded attachment fractured. Damaged bilge keel to be faired or cropped off. Fractured welding to be chipped out and rewelded. RUDDER 5. Pintle inspection plate, port side of rudder, missing. To be renewed. PROPELLER 6. Tips of 4 blades of solid bronze propeller slightly bent and nicked. Blade tips to be heated, faired, and dressed smooth. IAILSHAFT AND STERN BEARING 7. Oil lubricated stem bearing reported to be leaking and losing oil. Stem bearing to be tested with head of oil to determine source of leakage if possible. CONTINUEDnu. Baport la laaoad mbjeet to th condition that It li uadantood aad umd that nrttbar tha Sanaa nor . aw of lta Committee. la uadar any clreumitanees wnatanr to ha i--1 --p--far any tnaccnraey la cay raport or eartldeata lamed by thia Bureau or lta Surrayon or In any entry in tha Baeord or other TinWIretlon of tha Sanaa or for any error of ludcmeat. defaalt or nwllceaoa of lta Offlean. Sorrayon or Aaaata. Htttad In OJSJL EXX-MOR-005813 Report No. NN5253 -2- S/S "ESSO BOSTON" 8. Bearing tight: under head test. Tailshaft to be disconnected and drawn in for examination includ ing magnetic particle test. Inne and outer bearing seals to be removed for examination and bear ings examined. 9. Tailshaft satisfactory. Outer bearing seal found fractured in several locations with evidence of some overheating in way of inner lip. Some foreign matter present in seal and bearing. Condition of inner seal suspect. Inner and outer bearing seals to be renewed. Bearings to be cleaned. Tailshaft to be rein stalled and all connected as before. Assembly to be tested and proven tight. Propeller to b wedged cm, nut driven up and void spaces filled with rust inhibitor MAIN CONDENSER IQ. Condenser subjected to fouling by mud and foreign matter during ground ing. .11 .12 To be opened, examined, cleaned and tested as necessary to prove satisfactory. Necessary removals and replace ments to effect repairs. Necessary staging. 13. New and disturbed work to be coated as before. 14. Necessary dry docking. The foregoing reconmendations were satisfactorily carried out at this time and it is further recommended that vessel be retained in present class with this Bureau, being on November 26, 1963 in the opinion of the undersigned in seaworthy condition. Charles R. on - Surveyor. EXX-MOR-005814 FORM A.B. 1 0-7A AME^CAN BUREAU OF S :PP|NG /y / report NONN5252 NO. U^^|CpRD SURVEY REPORT/// NAME OF VESSEL O* j , S/S "ESSO BOSTON" // OWNERS Humble Oil & Refining Co /'. ' HULL BUILT BY Newport News S. B . & D. D. Co HULL NO..54^ CLASS IN FULL 4AMS 5/fft /?OQ /' DESCRIPTION OF SUHVEY /PORT OF SURVEY Newport News PORT OF REGISTRY Wilmington. De. GROSS TONNAGE 30680 date n - I96q DRY DOCKING AND REPAIRS - ANNUAL SURVEY - ANNUAL LOAD LINE SURVEY - COASTWISE LOAD LINE CERTIFICATE - TAILSHAFT SURVEY $ invoice no. NN7249 DATE 12-3-63 TOs Humble Oil & Refining Co Marine Department P. 0. Box 1512 \f Houston 1, Texas ATTENDING: Mr, F. Newton - Ren. Owners Mr, T, Hu3hion - " U.s.C.fi. Mr, P, Bannister U.S.C.G. pgpp CHARGED SS (H) DD $ 90. AS 90. SE ALL 35. SS (RMC) CONT. (RMC) SS (M) ts $65. CQgJ/ERSION SR RLL INT (RMC) WT APPROXIMATE COST OF REPAIRS FOR ENTRIES BY REPORT DEPT. ONLY SS (E) BS ACG QCG DAMAGE SEMI-AN (RMQ OTHER $100. TANK VESSEL CARGO: REPORT DISTRIBUTION: OWNERS/AGENTS 6 ABS NEW YORK 2 COPY (IF ANY) - 4s. r /hM- '7/o //<} FEES $330.00 EXPENSES 3.50 ?383.d u TOTAL Billed - FTPST VISIT 11-25-63 NO OF VISITS rwapfSFAmF c2 . _ .* - ---------------- . \'4 ' \ ' - VISIT 11-26-63 Surreyor FrlMi I, U.3.A. G/K &&&*IslSTU Charles R. Hudsoil^^ EXX-MOR-005815 Ammran iBureau nf Shipping 45 BROAD STREET, NEW YORK 4, N. Y. Report No. NN5252 Newport News, Va. Nov. 26, 1963 S/S "ESSO BOSTON" THIS IS TO CERTIFY that the undersigned Surveyor to this Bureau did, at the request of the Owner's Representative, attend the steel screw S/S "ESSO BOSTON", Official Number 283,784- of Wilmington, Del., on November 25, 1963 and subsequent date as vessel lay on dry dock at Newport News Shipbuilding and Dry Dock Company, Newport News, Ya. In order to examine and report upon the condi tion of the vessel relative to Dry Docking, Hull Repairs, Annual Classification Survey and Tailshaft Survey and has to report as follows - DBY DOCKING: 1. The vessel was placed on dry dock and the keel, stem, stem frame and shell plating cleaned, examined and placed in satisfactory condition as follows - (a) Scattered leaking rivets and riveted seam on flat of bottom, port and starboard sides were caulked and made tight. (b) Fractured shell attachments of port and starboard bilge keels were chipped out and rewelded. (c) For further particulars of above repairs see report of Newport News, Ya. NN5253 dated November 26th, 1963. 2. The rudder was examined including pintle clearance and found satisfactory. Missing pintle inspection plate, port side, was renewed. 3. The propeller, 4 blade solid bronze, was examined and placed in satisfactory condition. Tips of all blades were heated, faired, and dressed smooth. 4. Overboard discharge and suction openings In shell plating were examined and found satisfactory. 5. Strainers were removed from sea chests and cleaned and recoated together with chests. Sea valves opened, cleaned, overhauled, ground in or machined and reseated as required, examined, repacked and placed in satisfactory con dition by minor repairs. The following valves were dealt with: Main low injection Sanitary pump sea suction and overboard discharge Brine pump sea suction and overboard discharge Aux. fire pump sea suction and overboard discharge One sea suction, after pump roam One sea suction, forward pump room Feed pump cooling water overboard discharge Generator cooling water overboard discharge mUfTVnra IWUllim ThU Itipm le 1--r* sRhleet to the condition that it la understood and aarood that neither tha Bureau nor * |gy jgg Cemmltteee la under anj etreumstanees whatever to he held reeponatbfle for ear Ibiwbtwt ta ear report or certificate lined by this Bureau or lte Surveyors or la any entry ta the Record or ether publication at the Bureau or tor say error of 1tidemeat, default or neelicence of lte Officer*, ffitrveyors or Acenta mated t& T7J3JL EXX-MOR-005816 Report No. NN5252 -2- S/S "ESSO BOSTON 6. Anchor cables were ranged, cleaned, examined, found satisfactory, and restowed* TAILSHAFT SURVEY; 7. Tailshaft clearance in oil seal type stem bearing taken by gauge and found to be same as originally, approximately .032". In connection with grounding and reported oil leakage, tailshaft was disconnected, drawn in, examined including magnetic particle inspection and tailshaft found satisfactory* Prior to drawing shaft, the stem bearing was tested hydrostatically with head of oil and no apparent leakage found* Subsequent to drawing shaft and after removal of oil seals, the outboard seal was found fractured in several locations in way of inner lip with evidence of some overheating and presence of foreign matter apparently due to grounding and subsequent refloating efforts. The inner and outer seals were renewed after installation of tailshaft, tailshaft reconnected, propeller wedged on, void spaces filled with rust inhibitor and all left ready for sea. Tailshaft drawn 11-63* For further particulars see report of Newport News, Va. NN5253 dated Nov. 26, 1963. ANNUAL CLASSIFICATION SURVEY: 8. Steering gear arrangements, crosshead, hydraulic pumps, motors and connections examined, telemotor rams and visible piping examined and found in order. 9. Watertight doors in bulkheads and vesselTs sides, closing appliances in the superstructure bulkheads and for air and sounding pipes examined and found satisfactory* 10. Coamings of ventilators to spaces below the freeboard deck and below decks of superstructure examined and found satisfactory. 11* Hatchway coamings, covers, expansion trunks, and all their supports and means for closing examined and found satisfactory. 12* Machinery casings, guard rails, and all other means of protection provided for openings and for access to crew's quarters were examined and found satis factory. 13. No material alteration has been made in the hull, superstructures, or means of closing openings in the superstructures which affect the position of the load line. 14. A general examination of engines, boilers, windlass and fire extinguishing apparatus was made and all found satisfactory so far as seen. 15. The Annual Load Line Inspection was carried out at this time. In accordance with instructions from New York Office, new load line marks for International and Coastwise certificates were cut in and verified and Provisional Load Line Certificates valid until May 25, 1964 were issued to the vessel. 16. Vessel undocked November 26, 1963. EXX-MOR-005817 Report No. HH5252 -3- S/S "ESSO BOSTON" 17. SIMftBT Dry docked 11-63 Annual Class Survey complete 11-63 Annual Load Line Inspection complete 11-63 Tailshaft Survey 11-63* It is recomnended that the vessel be retained in present class with this Bureau. Charles R* Hud! Surveyor. EXX-MOR-005818 rOAH A. I. fAt Afltmran iBursau nf dipping 45 BROAD STREET, NEW YORK 4, N. Y. Report No. NN5252 Newport News, Va. Nov. 26, 1963 S/S "ESSO BOSTON" THIS IS TO CERTIFY that the undersigned Surveyor to this Bureau did, at the request of the Owner's Representative, attend the steel screw S/S "ESSO BOSTON", Official Number 233,784 of Wilmington, Del., on November 25, 1963 and subsequent date as vessel lay on dry dock at Newport News Shipbuilding and Dry Dock Company, Newport News, Va. in order to examine and report upon the condi tion of the vessel relative to Dry Docking, thill Repairs, Annual Classification Survey and Tail-shaft Survey and has to report as follows - DRY DOCKING: 1. The vessel was placed on dry dock and the keel, stem, stem frame and shell plating cleaned, examined and placed in satisfactory condition as follows - (a) Scattered leaking rivets and riveted seam an flat of bottom, port and starboard sides were caulked and made tight. (b) Fractured shell attachments of port and starboard bilge keels were chipped out and rewelded. (c) For further particulars of above repairs see report of Newport News, Va. NNS2S3 dated November 26th, 1963. 2. The rudder was examined including pintle clearance and found satisfactory. Missing pintle inspection plate, port side, was renewed. 3. The propeller, 4 blade solid bronze, was examined and placed in satisfactory condition. Tips of all blades were heated, faired, and dressed smooth. 4. Overboard discharge and suction openings in shell plating were examined and found satisfactory. 5. Strainers were removed from sea chests and cleaned and recoated together with chests. Sea valves opened, cleaned, overhauled, ground in or machined and reseated as required, examined, repacked and placed in satisfactory con dition by minor repairs. The following valves were dealt with: Main low injection Sanitary pump sea suction and overboard discharge Brine pump sea suction and overboard discharge Aux. fire pump sea suction and overboard discharge One sea suction, after pump room One sea suction, forward pump room Feed punqj cooling water overboard discharge Generator cooling water overboard discharge ,,. . CONTINUED TWa Bator* la laaoad cabinet to the condition that it la nndaratood and acreod that neither the Boraaa nor *%nr of lta Committee la under any circumstances vbaterer to bo bold moonalblo for any Inaccuracy tn any rooort or eertihoau issued by this Bureau or lta surrerora or tn any entry in the Record or other nublleatlon ef the Bureau or for any error of Judgment* default or neoUaenee of Its Officers* ffiuveyora or Aeenta. rrtntad In TJAA. EXX-MOR-005819 Report Ho. NH5252 -2- S/S "ESSO BOSTON 6. Anchor cables were ranged, cleaned, examined, found satisfactory, and restowed. TAILSHAFT SURVEY: 7. Tailshaft clearance in oil seal type stem bearing taken by gauge and found to be same as originally, approximately .032*. In connection with grounding and reported oil leakage, tailshaft was disconnected, drawn in, examined including magnetic particle inspection and tailshaft found satisfactory. Prior to drawing shaft, the stem bearing was tested hydrostatically with head of oil and no apparent leakage found. Subsequent to drawing shaft and after removal of oil seals, the outboard seal was found fractured in several locations in way of inner lip with evidence of some overheating and presence of foreign matter apparently due to grounding and subsequent refloating efforts. The inner and outer seals were renewed after installation of tailshaft, tailshaft reconnected, propeller wedged on, void spaces filled with rust inhibitor and all left ready for sea. Tailshaft drawn 11-63. For further particulars see report of Newport News, Va. NH5253 dated Nov. 26, 1963, ANNUAL CLASSIFICATION SURVEY: 8. Steering gear arrangements, crosshead, hydraulic pumps, motors and connections examined, telemotor rams and visible piping examined and found in order. i 9. Watertight doors in bulkheads and vessel*s sides, closing appliances in the superstructure bulkheads and for air and sounding pipes examined and found satisfactory. 10. Coamings of ventilators to spaces below the freeboard deck and below decks of superstructure examined and found satisfactory. 11. Hatchway coamings, covers, expansion trunks, and all their supports and means for closing examined and found satisfactory. 12. Machinery casings, guard rails, and all other means of protection provided for openings and for access to crew's quarters were examined and found satis factory. 13. No material alteration has been made in the hull, superstructures, or means of closing openings in the superstructures which affect the position of the load line. 14. A general examination of engines, boilers, windlass and fire extinguishing apparatus was made and all found satisfactory so far as seen. 15. The Annual Load Line Inspection was carried out at this time. In accordance with instructions from Mew York Office, new load line marks for International and Coastwise certificates were cut in and verified and Provisional Load Line Certificates valid until May 25, 1964 were issued to the vessel. 16. Vessel undocked November 26, 1963. EXX-MOR-005820 Report Mo. NN5252 -3- S/3 "ESSO BOSTON" 17. SUMMARY Dry docked 11-63 Annual Class Survey complete 11-63 Annual Load Line Inspection complete 11-63 Tail-shaft Survey 11-63. It is reconmended that the vessel be retained in present class with this Bureau. Charles R. ion - Surveyor. EXX-MOR-005821 FOM LL 80 AMERICAN APPOINTED BT TBS COMMANDANT. U. X CO OP MABCH 2. 1929. AND REPORT OF AimnOAD UNDER THE r. AMENDED JOKE LINE INSPEOtlOH REPORT NO. NAME OF SHIP '/ DATE LL 3526 GROSS TONNAGE 30680 S/S "ESSO BOSTON" OFFICIAL NUMBER PORT OF REC25TRY 283,784 Wilmington, Bel. OWNERS November 26, 1963^* ^ / PORT OF SURVEY / Newport News, Va. j ITEM EXAMINED l. HATCHWAYS Coamings. ittHnwn. itais. beams. Ion and often, carriers, carers, tarpanHns. cleats, battens, wedges ithH IpwIiIh^n Htmble Oil & Refining Company / CONDITION .i RECOMMENDATIONS -- REPAIRS HFECIQ) l Satisfactory L 2. MACHINERY CASINGS Fiddler openings, casings, doors, sills, skylights Satisfactory - -- X FLUSH BUNKER SCUTTLES Attachments 4. COMPANIONWAYS Doors, sills, fastenings 5. VENTILATORS Coamings, supports, deck connections, dosing arrangements -- Satisfactory Satisfactory B. AIRPIPI3 Closing arrangements 7. GANGWAY. CARGO AND COALING PORTS In ship's sides and X SCUPPERS AND SANITARY DISCHARGES Valves Satisfactory Satisfactory Satisfactory r/'-i'Ay - - ' EXX-MOR-005822 ITEM EXAMINED 9. A1BPOSTS 10. GUARD HAILS OB BULWARKS 11. FREEING PORTS Shnttnts. ban CONDITION ` Satisfactory Satisfactory .--------- --- RECOMMENDATIONS -- REPAIRS EFFECTED 12. PROTECTION AND ACCESS TO CHEW'S QUARTERS Gangways 13. LIFE LINES Satisfactory 14. END BULKHEADS OF SUPERSTRUCTURES Closing frppTL'nu u. rmA fastenings 19. TIMBER, TANKER AND SPECIAL TYPE Supplementary fittings 18. LOAD LINE MASKS Satisfactory -- Satisfactory New International and Coast wise marks cut in snd verified I have surveyed the above mentioned ship and am satisfied:-- (i) that the fittings and appliances for the protection of openings, the guard rafls, the freeing ports, and the means of access to the crew's quarters have been maintained in an effective condition, and (ii) that no alterations have been made to the hull or superstructures which would affect the calculation determining the position of the load lines. 1 ANNUAL;-- I have endorsed the load line certificate number.------ -------------------------------------as follows^ Signature RENEWAL:-- Flam Date 1 have renewed the load fine certificate numberas follows:- New InternalSBfiSl and Coastwise marks cut In and verified and Frovidional Load Line Certificates valid until May 25, 1964 issued to the vessel on Nova*.? 25, 1363. plac* 0al* _ ___ _ Benewed unfil___^_------------------------------ (JbLriLl7r /// Sui,,yqf,Amrir>in Bamcm of Shipping Charles R. Hudson This Report is issued subject to the condition dint it is understood snd agreed that neither the Bureau nor say of its Commutes is under say circumstances whatever to be held responsible for any inaccuracy in say report or certificate iaeaed by this Bureau or its Surveyors or in any entry in the Record or other publication of the Bureau or for any error of lodgment, default or negligence of its Officers, Surveyor! or Agents. Fm Exponses Thin ssml t. flnwmt Bureau im. . Has fids survay boon carzfod out at the same time as a corresponding survey re quired for maintenance of dms^md far which a fee has been charged? *?,,.___ Total .................... PlIKTID 1H . S. A. EXX-MOR-005823