Document npaErb4K9p2ZJw891VoD836pX
j X.'o.'U.*0 v.--u.ij-'j LI.
A. f J-l'/^i v;',..^i,r
.-..'a.
f.VfA Gi .aaV AOS ?4o - A purified concentrate of scavenger In Aroclor
1. T;-:-JXD'JC;nOH
Following the release of details in the improvement in capacitor li
under severe ageing conditions that con be obtained by incorporating a
scavenger in tho uokarcl impregrant (see references 1,2,p,), v;o
roe-iVv-X
requests from several capacitor ,;>unufacturera to supply the aduiwive in a
purified and concentrated form. C-ur Organic Research Department in 3t. Laaia
hao perfected a method of producing a mixture of exceptionally high purity
containing 'j>Q,, of the scavenger, and v;e have been authorised by the General
Jloctric Company (U.S.A.) to distribute samples of this concentrate to
interested capacitor manufacturers so that they can try it out in their own
designs, ouch trials will enable capacitor manufacturers to make u technical
and economic acsessr.ient of the value of this development in relation to X.c.ir
particular commercial circumstances go that they will be better able to
or. informed decision on licencing arrangements.
.
2* PAOFLkTlfS
The Sumples consist of a mixture of Aroclor 1242- and vinylcyelokexe.se
dioxide (commercially known as
or Unox 206) in the proportion of >0: f
by weight. They have been subjected to careful purification so that the
addition of tho scavenger does not result in an unacceptable deterioration of
the electrical properties of the final improgn&nt. iieasurer.ients of the
oloctrical properties of diluted samples were made by our Organic Research
Dep<rtment and gave the following results:
HONS 034769
n
2.
oam.plo
Aroclor 1242 only Aroclor 1242 + 0.5/- scavenger
Aroclor 1242 + 6,0,. scavenger
Dissipation factor at 100 0, 60hzU)
0.056 0.83
Aesisti'/ity
',00"*.,
;
500V, 1 rain clectrifleabioa '
... c;" !
151 1
28 i
Z.Z !:
goto:
Dielectric test colls used to Measure the electrical pro^rtica of ca...ples containing the scavenger arc much wore difficult to clean than colls used to measure contaminated Aroclor having similar electrical properties caused by other impurities.
5. ;u?LICATIOK
The published information indicates that a scavenger content of 0.5/. V -' in Aroclor 1242 provides a satisfactory level of protection. This seayor.gor content cun be obtained by diluting one part by weight of the >C.. ccncc.itraco with 166 ports by weight of pure Aroclor 1242. Since eacn so...pie bottle contains about 0.5 kg. of 5$- concentrate, it is capable of providing about 65 kg. or 60 1 of Aroclor 1242 with a scavenger content of O.5.- w/w*
Since the scavenger has a higher vapour pressure than Aroclor 124-1 (aboi.c 200 times greater at 20) it con be depleted by vigourouo prolonged dejassi/.g treatment. Careful consideration should therefore be given tc tho ue^. suing conditions: ae low a temperature and as short a time as possible will favour the maximum retention of the scavenger in the Aroclor 1242.
Treatment with fullers' earth or activated alumina removes the scavenger from the Aroclor. It is therefore necessary to carry out ar.y such purification of the Aroclor 1242 before the addition of the scavenger. When flood impreg nation ie employed and the excess Aroclor 1242 whioh has been contaminated during the impregnation must be ro-purified for further use, this purification
HONS 034770
should bo us rj.'.ort i.r.d a; as low a to:..poruturj a.. conserve the scavenger content of the Arcelor 12-i 2. After .
ccavor.gor content should bo estimated by t.;o-:..ethed given in tier. of this publication, lvau the quantity of concentrate v.i.i od to restore the desired scavenger content: should be calcula
n-v--Jla..L . ..ji'iiCP FuK .1 General
-<hr.h .AI'iAi. a.*1*2l*i-4.t5SC AVa. .GbA Cb.f, ....i.
Since the scavenger can be depleted by vacuum or earth tre___one., is necessary to have a readily available .Method of estimating b.._ c..
present in the Aroclor 1242 at various stores of the impregnation _,rc Hie ...othod given hero is speedy and unlikely to be affected by the r
of the usual contaminants arising in capacitor impregnation plants. 4.2 rrli:ciplo
The method involves titrating the oxxrone oxygen in glacial acetic
vath a standard perchloric acid solution to a crystal violet cnc-point
The titration is carried out in an excess of quaternary ajciv.cnium bro...i
which, on contact with perchloric acid, produces hydrogen bro...ibe.
hydrogen bromide, in turn, reacts with the oxirane oxygen. (Reference
4.5 Reagents 1) Glacial acetic acid.
2) Chloroform.
5) Perchloric acid solution - 0.1N in glacial acetic acid. (Standardize against potassium hydrogen phthalate).
4) Crystal violet - solution in glacial acetic acid.
5) Tetraethyl ammonium bromide solution - dissolve 100 g ir.
400 ml of glacial acetic acid.
'
.
4.4 Apparatus . 1) 10 l.;l buret
2) Usual laboratory glassware
4.5 Procedure 1) Weigh 2.5 to 50 S of Aroclor 1242 to the nearest 0.05 b into
a 125 mi Srlexuseyer flask.
HONS 034771
/4
2) Add 10 ml of chloroform, 40 nil of glacial acetic acid and 10 ml of the totraothyl ammonium bromide solution arid swirl to diccolv-.
3) Ada 1 drop of crystal violet indicator and titrate with 0.1;; perchloric acid to the greatest colour change (violet to grcan-'oluo).
*1.6 Calculation S,, cavenger con.ten.t /(*',*)\ -7-.-0--1----x^--T----x---i-:
whore T * titre of perchloric acid (ml) N * normality of perchloric acid. W - weight of sample (g)
4.7 Additional note's
1) The titr&nt is very stable and does not require frequent restondard-
ization.
2) Ko blank correction should bo required if good quality reagents are
used.
?. T0XIO1TY AND HANDLING PRECAUTIONS
... ..
Prolonged and repeated contact with the concentrated product may cause delayed
and serious injury to the skin. When handling it protective gloves and eye shijld
should be worn to avoid the possibility of skin contact or splashes in the eyes.
Tho inhalation of vapours or mists should be avoided. In the event of it ju'iiing
on the skin, wash thoroughly with plenty of soap and water. If it gets on tii clothes or shooe.remove them and wash them thoroughly before wearing them again.
In the diluted state this product can be safely handled following the normal precautions listod on page 21 of our Technical Service Bulletin "Aroclor for Capacitors". However, the possibility of this scavenger becoming concentrated in certain parts of the impregnation plant such as filter beds or water cooled baffle chould not be overlooked.
6. RSFaRLiXEa
..
1) General Electric Company (USA).. BP No, 9^6 950 of 20.8.63. 2) Henry H. Stahr et al. USP No. 3 242 402 of 22,3.66. '
3) J. Coquillion. GIGRE Paper Ho. 1967-68-2. 4) R.R. Jay. Anal. Chem. 6, 667 (1964).
HONS 03<7 72
/5
5.
7 DISCi^AIMiSR
The information given in this publication is given in good faith but
without acceptance of liability. Freedom from patent rights must not be
assumed, Aroclor is a registered trade mark.
-
CSCjSKH 3rd Ootober, 1968.