INSTRUCTIONS FOR THE LEADER AROCLOR UNIT
939?
INSTRUCTIONS FOR THE LEADER AROCLOR UNIT
I. SAFETY 1. Aroolor is not flammable. Indeed it will not burn. However, because of the possibility of foreign gases being present, an air or nitrogen sweep should be used in an Aroclor line when welding on it. 2. Aroclor vapors are very unpleasant and the health hazard is slight. However, the vapors are somewhat irritating to the nose and throat and should be avoided. 3. The chief hazard of Aroclor is the high temperatures that are likely to be employed. 4 . It is possible for the main burner to belch flame back out bottom of the heater, particularly on start-up. For this reason, make visual observation for pilot flame from Freon Building steps and for main burner through the observation window on East side (a lever on side of window opens it for viewing).
II. EQUIPMENT NUMBERS OF THE PRIME UNITS Reservoir C.T. 4644 800 gal. steel tank rated at 50 lbs. allowable pressure. It contains a hair pin steam coil. Heater Mlsc. 790 A radiant-convection, three million BTU/hr. heater. Radiant colls are 4" vertical hair pins and the convection coils are 4" horizontal. MONS 092398
Inst, for the Leader Aroclor Unit (con'd.)
page 2
Tump 3298
A Dean Brothers type SMR-10, water cooled mechanical seal,
,00 gpm. at 160 ft. head. SO.**'
*7 / ?7O HP.M.
Cooler H.E. 242 A 229 sq. ft. steel heat exchanger using U tubes. It Is 12" x 12 ft.
HI. ABPCWP 1. Aroclor comes In several grades. The grade used In this
system Is No. l&tft. / -* "V-~
2. The pour point Is -7*C. (19-J+0F-) Tracers, therefore,
will have to be used on the vent system and the circulating
lines in cold weather.
,. Aroclor 12*t8 begins to decompose, or coke, at temperatures
above ,20C. The over temperature control must be set to
limit the temperature to ,20oC. maximum.
^. Water In Aroclor generates hydrochloric acid which attacks the Iron. Therefore, water must be kept out of the system
by blanking at service headers, blowing (when necessary
to blow out Aroclor lines) with nitrogen and not air, and
by venting the system thru a heated vent on the surge tank.
5- Analysis of fresh Aroclor: Water - less than 100 PPM, or .01#
MONS 092399
Acidity - less than .05#
Viscosity - 75 to 80 Saybolts per seconds at l,oP.
(^ Kn.ri uummminir'jl.c'-hj i lxaexbu9st wiinll ri-uunu tthnee3se..)/
-
(U\&>nipz -
J
'7', A AAA-S^'A' As
AS~/S*<S/
Inat. for the Leader Aroolor Unit (conH.)
^ Jnclru^^- Mb*'
tf'Htjbc&ktf/
IV. AROCLOHDISmiBUTION SYSTEM
/, ,,
page j
" &*.2***y
.
'
The Leader Unit Is originally and primarily for the high
vacuum still and the multitube still, however, by removing
blanks it can be connected to the yard unit distribution
system.
V. Q.BHBAl HSlfiS 1. With the Aroclor circulating, the reservoir should be lA to 1/2 full. 2- When Aroclor temperature is below 200C., operate burner by manual control (starting at lowest heat) until 200C. is reached, then go to full and automatic heat. 5- when shutting down, leave Aroclor circulate for 1/2 hour after shutting off flame in order to dissipate heat In the combustion chamber. Also turn toggle switch on panel to off and close manual valves in both gas lines . 4. Following an interruption of Aroclor circulation for any reason (such as a power failure) when temperature 13 above 200C. circulate for a few minutes to get rid of any vapor pockets that may have formed in the heater tubes before turning on main burner.
VI. COMPONENT UNITS 1. Vent A 1-1/2" vent to the raw atmosphere is provided atop the reservoir. This vent is steam traced so as to heat and dry the breathing air. HONS 092400
Inst, for the Leader Aroelor Unit (con'd.)
page 4
Rupture Disc A 4" x 20 lb. Karbate rupture disc Is provided on the reservoir. The 4" discharge line is against the building and 18" off of the ground. Pop Valve A 1" pop valve is provided on the outlet from the heater. It is set at 85 lbs. and discharges to the reservoir. Masonellan Automatic By-pass Valve To insure an adequate flow (about 300 gpm) thru the heater coils at all times and yet maintain a satisfactory flow to the user, a Masonellan valve is provided as a by-pass. It is controlled by the Plow Recorder. Pressure at pump discharge 3hould be about 80 lbs. and on the line leading to user, about 55 lbs. Low Flow Gas Shut-Off The Aroelor must be circulating in order for either the pilot flame or the main gas flame to burn. When the Aroelor is circulating at at least 170 gpm, a differential across the orifice reacts on a transmitter which in turn reacts on a Mercoid switch. When^the pressure drops off, the Mercoid switch nc^jaiescloses the solenoid valves in
both gas lines . A low flow shutdown is indicated by a red light on the right of the panel board. After the low flow situation has been remedied, the low flow reset button will douse the signal light.
HONS 092401
Inst, for the Leader Aroclor Unit (con'd.)
page 5
6. Pump Motor Failure Gas Shut-Off
To serve as a back-up for the "No Flow Gas Shut-Off" and
to act as a double guard against having a flame on when
there Is no Aroclor circulation, an auxiliary contact
point is provided on the pump motor.
7. Flow Recorder-Controller
The Flow Recorder controls the Masonellan by-pass valve.
The flow recorder-controller gets lt3 3lgnal from the
flow transmitter which detects pressure drop across an
orifice In the Aroclor line. It has three operating
positions} Manual, Seal and Automatic. Normally It will
be set on automatic. Seal can be used In start-ups to
avoid a surge of Aroclor In the lines . Manual may be
used at times when some of the automatic controls fail.
The black pointer Indicates the ratio of by-pass (the %
the Ma3oneilan Is open). The top red pointer is the set
point and the bottom red pointer indicates the flow through
the heater on all of the three positions.
8. Over Temperature Gas Shut-Off
A Protect-O-Vane located at West side of heater shuts off
both flames when the temperature of Aroclor gets up to set
point on the Protect-O-Vane. This must never be set higher
than 320C. A red light on the Protect-O-Vane case comes
on when it has shut off the flames. A reset button near
the light has to be pressed and held in for about 30 seconds
before flames can be re-established.
MONS 092402
Inst, for the Leader Aroclor Unit (Con'd.)
page 6
9 Purge Blower and Timer A blower mounted half way up on North side of heater purges the combustion chamber for 2-1/2 minutes before start-up. The blower is controlled by a timer inside the panel case.
10. High-Low Gas Pressure Shut-Off Mounted on both sides of the Fisher gas pressure regulators are Mercoid pressure switches. The high pressure on down stream side of regulator is set at 15 lbs. and the low pressure on up side of regulator is set at 10 lbs. If the regulated gas pressure gets above 15 lbs or if the main gas pressure gets below 10 lbs, both flame3 are shut off.
11. Maxon Safety Shut-Off Valve The Maxon valve ha3 to be manually opened. It is in the main burner gas line and closes when either flame goes out.
12. Auxiliary Safety Shut-Off Solenoid Valve Down stream of the Maxon valve is a Solenoid valve which closes at the same time as the Maxon. Its purpose is to insure no gas leak through. Between the Maxon and the Solenoid valves is a branch line with a small Solenoid valve which is opened at the same time the other two valves close. This serves as a bleed-off of any gas between the two safety shut-off valves.
MQNS 092403
Inat. for the Leader Aroclor Unit (Cortd.)
Page 7
13. Main Burner Control Valve Down stream of the two safety shut-off valves Is the air actuated modulating valve for the main burner ga3 feed. It Is controlled by the Brown recorder-controller.
14. Protectoglo Relay The Maxon valve, the auxiliary Solenoid valve, the bleedoff Solenoid valve (see paragraphs 11 and 12) and a safety shut-off Solenoid valve in the pilot gas line receive their signal from a Honeywell Protectoglo relay (the large box inside the panel ease). The Protectoglo relay receives Its signals from any of the following: Low flow switch. High-low air pressure switches. High-low gas pressure switches. Over temperature switch. Toggle switch on panel board. Flue damper switch. Pump Motor contact The horns at both the panel and the annunciator will sound and both flames shut off when the Protectoglo actuates. Failure of the Protectoglo relay (as well as the Purple Peeper) will also shut off the flames and sound the horn.
HONS 092404
Inst, for the Leader Aroclor Unit (Con'd.)
page 8
15* Purple Peeper and Marlon Meter The Purple Peeper monitors both the main burner flame and the pilot flame. Mounted in the wiring line between the Peeper and the Protectoglo Relay is a Minneapolis-Honeywell ammeter. Output of the Peeper Is about 4 microampere, if above two mlcroampers the Peeper Is getting a good look at the flame. If below two, something is obstructing the Peeperte view of the flame.
16. Flue Damper The Flue Damper is set for the proper draft and should not be changed. However, there is a safety switch connected to the damper and this shuts off the flames if the damper Is closed.
17- Air Supply The air supply is off of the H.P. air system. It Is fed In thru a Fulflo filter, a pressure regulator (set at 55 lbs) and a Deltech filter (cartridge turns red when it needs changing). The air is used to activate the main burner control valve, the Masoneilan by-pass valve, the Brown temperature recorder-controller and the flow trans mitter and flow recorder-controller. Inside the panel case are two air pressure switches; low pressure set at 5 lbs and high pressure at 25 lbs. On either side of these pressure settings, the flames are shut off.
MQNS 092^05
Inst, for the Leader Aroclor Unit (Con'd.)
page 8a
18. Secondary Damper The secondary air damper on the furnace Is located at the bottom of the combustion chamber. The damper Is positioned by a pneumatic operator, which receives the same air signal as received by the main burner gas control valve. As the tempera ture controller opens the gas valve. It also opens the air damper, allowing more air flow for combustion.
The secondary damper was set on 9-10-65 to provide the follow ing excess air levels for combustion:
Fuel Qas Valve
100# Open 80#
6o#
40#
Approximate Excess Air
25# 50# 100# Greater than 100#
The high excess air figures at low fuel gas flows is caused by air leakage around the moveable parts of the damper.
MONS 09^406
Inst, for the Leader Aroolor Unit (Can'd.)
page 9
VII. TO START-UP WHEN UNIT HAS COOLED (BELOW gQOC.) 1. Have valves In Aroclor lines set to pump thru the heater and to the user. 2. Have pilot gas manual valve and the main burner gas cock both open. 3. Have cooling water on Aroclor pump seal and bearing. The water to the lantern ring should be regulated to 5 pslg4. Have Aroclor pump on with Aroclor circulating through the heater at 200 gpm, as indicated on the flow recorder. 5- Turn temperature control selector switch to "Manual" and set "Manual Control" air pressure gauge to 10 lbs. 6. Throw toggle switch on panel to "On". The horn will then sound, push "Silence Horn" button, then push "Low Flow" reset button to turn off the low flow signal light (if on). Then push "Purge Start" button. 7- When the "Safe Start" light comes on after a 2-1/2 min. purge delay, push "Flame Start" and HOLD IN for about 5 seconds, repeating until "Pilot On" light comes on. (Several pushes on the "Flame Start" button may be necessary before Ignition Is achieved.)
MONS 092407
Inst, for the Leader Aroclor Unit (Con'd.)
page 10
8. If pilot light does not come on, wait 2-1/2 min. and try again. Check for pilot flame by looking thru aperture where pilot gas line goes thru burner (squatting on Freon Building steps). Do not go in under heater.
9- Throw lever of Maxon safety shut-off valve in main gas line to open. The main flame should come on right away but will automatically stay on low flame for 1 minute.
10- When temperature reaches 200C., a) set Aroclor flow up to 300 gpm or normal b) switch temperature controller to "Automatic" and set the Brown recorder-controller pointer at the desired temperature.
vm. TO RE-START THE UNIT WHEN IT IS HOT (ABOVE 200C.) When there has been a temporary interruption of flame and the Aroclor is still above 200<'C., it is not necessary to re-start on "Manual Control". Set the pointer on the Brown recorder-controller to the desired temperature of the Aroclor before pressing "Purge Start" button. After "Safe Start" light comes on (after 2-l/2 minutes), push "Flame Start" button and hold in until "Pilot On" light comes on.
Notts 09240a
Inst, for the Leader Aroclor Unit (Con'd.)
page 11
IX. TO COOL THE AROCLOR First turn water on full to the cooler. Next open the high valve in cooler outlet, then close the valve (above pump) in inlet to the heater and open the adjacent one which leads to the cooler. The Aroclor flow will include the user if valves at the user are open. If they are not open, the circulation will be at the Aroclor unit only, circulating thru the Masoneilan by-pass valve. NOTE: Do not let Aroclor flow exceed 320 gpm, or the pump motor will overload. When Aroclor temperature is below 200C., do not allow flow to exceed 250 gpm.
J. A. Stepp D. B. Redlngton cs