! V NONPOLLUTING TRANSFORMER FLUID . .V I ' dow-corn:ng is asking industry help , IN OBTAINING SILICONE CERTIFICATION . \ V. effects have the pressures to reduce energy bed on ipeelficition? A New Jersey design firm says, `Transformer vendors are required to submit loss figures with their quote so that we can make an economic study based on client payout period. A 5% to Cft Initial cost saving for a less efficient transformer can rapidly be offset by a more efficient one." _ --- Another engineer wrote: "We require contractors to reimburse the owner for substitutions of equipment widt ilgher operating costs." Further comments noted specs for better power fector :orreetion. emphasis on life cycle costing and demand limiters `or industrial plants, lower lighting levels, higher efficiency ight sources and flexible twitching of lighting were also nentloned. ' . -. A cloar silieono dielectric coolant liquid Is being offered by Dow-Coming, Midland, Mich., for use- in small and medium- ( sited power transformers at a safe alternate to the chemical ___.Fsk^fjl coqipinjqg pCB, a substance that'is.nQw^being^vidfly.. . t condemmed as dangerous when discharged into tho environ* T jment. . . * . 1 h. r',.Extensive date from a series of tests by both Dow end soma transformer manufacturers indicate that silicone liquids ' provide a high degree of safety when used as o subsltuta for i askorols in both indoor and outdoor transformers. It is with 1 the Indoor applicotions that the problem arises sinco theta * transformers cannot (according to electrical codos) be )nsu(otcd with oil, an environmentally sofa subsUnco, but with glow flesh point. . .. ` There is o problem however in thot the silicone materlaf does not hevo Notional Electrics! Code or OSHA recognition, and it docs not have third party certification by an orgsnitatlon Vuch as Underwriters Laboratories. " . .v pow says that so far, three North American manufacturers ' ire using the silicone dielectric fill in some of the transformers they ship on request. These are IVestinghoura, PTE Corp., end Fcrrend-Peckard, ltd., of Canada.. In these cases, ' acsponsibility for proper clearance with insurance underwriters, government regulating agencies and local coda authorities ram with the user or purchaser of the liquid In new or refilled transformers. Tho silicone fluid also costs about twice as fnuch as eskorcl at present. - - - *ln the next few years, all existing eskercl trensformers it Dow Coming will bo retrofitted to eliminate tny chance of major PCD environmental contamination end to create o best for e service life data collection program. This test is hoped )o Include up to 1,000 transformers. 1 ffv While not quite as resistant to Ignition as askerels, end differing in certain other performance characteristics, the silicone fluid produced by Dow will not ignite before reaching *e temperature of 760 F., but it is not classed as fire-resistant. ^ If the heat source is removed or fluid temperature drops below 750 F., burning will stop and die fluid is therefore self* 'extinguishing. This is much better than bil but not as good as the askercls with PCBs* which arc considered dangerous to fish and wild life and capable of causing sickness in humans. ' ' Dow-Corning is presently asking both manufacturers and transformer users to porticipato in its testing program. Users would participate under an agreement with Dow and their . local code authorities whereby-transformers would be . refilled with silicone fluid. - ,. . V# KONS 32^