Document npJw8pjvqEmq5jgmQBqLZ6pkX

Boilers HEGGIE-SIMPLEX BOILER COMPANY JOILET, ILLINOIS General Sales Office, 1909 Conway Bldg., CHICAGO Cleveland Denver St. Louis Toledo Cincinnati Oklahoma City Charlotte, N. C. Columbus Detroit Milwaukee Memphis New York Minneapolis These Boilers Will Heat All Radiation Shown by Their Capacity Simplex combines both firebox and double return tubular types of boilers into one. Providing: An unusually large direct firebox heating surface. Double return tubular flues which force tong gas travel and insure thorough utilization of heat. A smoke-burning arch which forces soot and gases to ignite through contact with the burning fuel. A large combustion chamber in the rear of the firebox which insures thorough combustion before gases are allowed to pass into the flues. A single body of water, in direct contact with every heated surface, that circulates freely around the tubes and firebox, unimpeded by pipe connections. Simplex Boilers bum any fuel--Coal. Oil, Gas or Wood. They burn smokelessly and save 25% to 40% in consumption. Occupy only 2/3 the floor space ordinarily needed. Come in one piece (except base) ready for setting--without rivets, pipe con necting or bricking. There are no laps to break and leak, no ordinary iron castings to crack and no brick work to leak air and spoil draft control. Simplex Boilers are electric arc welded, built according to A. S. M. E. Code--of flange steel plate.Working pressure 15 lb. Tested to 1001b. Hydro static pressure. Fully guaranteed. SIMPLEX WATER HEATING GARBAGE BURNERS The back and forth flue travel, together with the complete manner in which the water surrounds every heated surface in Simplex Heaters produce savings of- 30% to 60% in fuel. Catalog Number........................... 35 36 37 38 39 40 41 42 Capacity, Gallons per Hour........ Height Over-all............................ Dimensions of Floor Space Re quired.................................... Dimensions Over-all.................... dimensions ot Lower L*rates___ .In. Size P low and Return................. diameter ot Smoke Pipe............. Approximate Shipping Weight... 600 800 1000 1200 1500 1800 2200 2600 60 60 60 66 66 68 68 68 79x76 29x32 29x39 36x39 36x46 41x41 41x47 41x53 28x31 28x37 28x44 36x44 36x5(1 41x44 41x51 41x58 22x2<J 22x2b 22x3J 28x33 28x38 33x32 33x38 38x44 2'/7 2Vt 2'/2 2V? 3 3 4 4 10 10 10 11 11 12 12 12 1750 2000 2250 2450 3000 3300 3700 4000 262 Note how water circulates through tubes forming garbage grate; ample grate area; simplicity of construction. Heggie-Simplex Boiler Company Boilers SPECIFICATIONS, SIMPLEX STEEL HEATING BOILERS No. of Boiler...... 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 850 100(1 M5( 1300 160(1 90C 2200 2600 300C 3500 4000 4500 5000 5500 6000 6500 7000 7500 Water.. 1400 1650 I90C 2100 2650 IOC 3600 4300 49(XJ 5750 6550 7400 8200 9000 9850 10700 11500 12300 1613 1791 1877 2042 7377 7V 2939 3448 373C 4557 4832 5323 5501 5785 6094 6828 7103 7479 259 276 290 277 319 370 361 402 444 436 457 478 518 338 550 559 580 601 401 401 401 470 470 470 649 649 649 998 998 998 164 1164 1164 1537 1537 1537 33 .33 33 33 33 33 34 34 34 37 37 37 37 37 37 45 45 45 * Firing Tools... 24 24 24 24 24 24 26 26 26 29 29 29 29 29 29 36 36 36 " Total........... 2320 2525 2625 2872 3216 1621 4009 4559 4883 6057 6351 6665 7249 7553 7874 9005 9301 9698 Width............... Width rUSox............... Grate Area..................... B 5 10 11 5 13 16 19 22 26 30 35 40 45 27 27 27 30 30 30 34 34 34 40 40 40 52 58 64 56 70 87. 79 91 103 92 98 104 22 7? 22 75 75 25 29 29 29 34 34 34 31 37 43 37 49 61 55 67 79 66 72 78 4.4 4.< 4.4 5.67^ 5.67 5.67 7.88 7.88 7.8t 10.66 10.66 10.66 50 55 60 65 70 75 47 47 47 52 52 52 101 107 113 109 115 121 41 41 41 46 46 46 72 78 84 78 84 90 2.87 12.87 12.87 16.52 16.52 16.52 14 14 14 18 18 18 20 20 20 22 22 22 24 24 24 26 26 26 12 12 17 16 16 16 18 18 18 20 20 20 22 22 22 24 24 . 24 Height " ................... 40 40 40 50 50 50 55 55 55 60 60 60 65 63 65 70 70 70 20 20 20 26 26 76 28 28 28 30 30 30 34 34 34 38 38 38 * Stack 2 Boilers... 18 18 18 24 24 24 76 26 26 28 28 28 32 32 32 34 34 Height a 2 ` ... 50 50 50 60 60 60 65 65 65 70 70 70 73 73 75 60 80 80 4 44 14 46 6 6 6 6 6 8 8 6 8 8 8 2 22 :2 73 * Safety Valve.......... IV? IV? Wz VA IV? Wz 2 Diam. Rues................... 33 33 i3 3: 3 3 3 4 4 * 2 ; IV, 2/2 2/2 T>h 2Vi 2 33 3 3 3 3 3 333 y/t V/z y/z Required................... 45 50 55 55 65 75 80 90 100 100 104 110 116 126 132 140 147 Height Water Line........ 55 55 55 58 58 58 62 62 62 69 69 69 72 72 72 77 77 77 No. of Boiler............ 119 6500 ` Water.. 13950 8426 626 1770 45 * Firing Tools . 36 " Total.......... 10903 " Width............. Width Firebox.............. Grate Area................... 85 57 121 51 90 20.61 Height * ................. 28 26 75 Height "2 * 40 36 85 Dia. Rues..................... 8 : 120. 10000 16400 8733 66i 1770 45 36 11251 100 57 133 51 io; 20.61 28 26 75 40 36 65 8 4 3 3Vi 121 11000 18050 11115 1019 1859 51 - 36 14080 110 63 173 57 90 22.95 30 28 75 44 40 85 10 5 W? 3</i 122 12000 19700 11549 1047 1859 51 36 14542 120 63 129 57 96 22.95 30 28 75 44 40 65 0 5 V/z 3Vj 123 13000 21300 12021 1087 1859 51 36 15054 130 6; 135 51 102 22.95 30 28 75 44 40 85 10 5 3'/ 3/ 124 125 126 127 128 129 130 131 14500 15500 I650C 18500 2000C 22000 2500C 28000 23800 25400 27100 30350 328IA 36100 41000 45900 13556 1092 2269 55 39 14120 1126 2269 55 39 14656 II6C 2269 55 39 16492 1188 2573 64 45 17771 1236 25/3 64 45 22041 1276 2933 U 45 23619 1344 2933 45 25197 1412 2933 45 17011 17609 18175 20362 21709 26367 28013 29659 145 70 129 63 % 28.21 155 70 135 63 102 28.21 165 70 141 63 108 28.2 185 200 220 250 280 78 78 141 153 153 165 177 72 72 77 77 77 102 114 114 126 1 35.51 35.31 37.68 37.68 3/.68 34 34 34 38 38 42 42 42 37 80 32 80 32 80 36 90 36 40 90 too 100 100 50 50 50 54 56 56 56 46 46 46 50 50 54 54 54 90 90 90 100 100 110 110 110 .10 10 10 12 2 12 12 12 5 5 5( 56 4 4 4 2-3/2 2-3/2 2-4 2-4 2-4 M 3/2 3/2 4 4 Sq. Ft. Boiler Covering Required................... 165 180 . 180 190 197 205 215 222 240 260 280 310 340 Height Water Line. .. . 80 80 92 92 92 95 95 95 104 104 111 111 111 263