Document npJLEZ90DrZnRryJO4YKJXgom

0310398 O bio iw TOWOLDMONOQ35582 | OOVOTSO IT 1 ;1 PYDRAUL AC saves maintenance costs A serious problem facing air compressor operators has been the high maintenance costs of cleaning valve deposits caused by petroleum lubricants. Further difficulties are high exhaust temperatures resulting from mal-function of valves and high cylinder temperatures that cause varnish deposits on cylinder rings and walls. With years of experience in the synthetic lubricant field behind them, Monsanto researchers sought the answer to this plaguing problem. After testing many types of fluids, they found a fire-resistant lubricant that proved to be ideally suited for air compressors. They called it Pydraul AC. Pydraul AC reduces exhaust valve and air compressor piping deposits to a minimum in all types of air compressors. Fewer carbon deposits on exhaust valves and in interstage equipment means a substantial savings for the operator who must pay the cost of cleaning as well as the cost of down time on the equipment. Lower maintenance cost alone usually justifies the use of Pydraul AC in air compressors. removes explosion threat There are nearly as many theories as there are men voicing opinions as to why fires and explosions happen in air compressor systems, but one point is generally agreed upon: petroleum oil lubricants are directly involved. Apparently, oil mist and films gradually accumulate throughout the air system. These break down into combustible gases and carbonaceous residues that can ignite to produce an explosion or receiver fire, or both. Pydraul AC has proven its ability to reduce these hazardous residues to an absolute minimum or eliminate them completely! By minimizing residues, Pydraul AC effectively reduces the threat of compressor fires and explosions. And Pydraul AC is fire-resistant. It provides safe operation, protecting not only the equipment, but the lives of workers as well. TOWOLDMON0035583 COMPRESSOR EXPLOSIONS.... UNPREDICTABLE The history of compressor explosions shows an unfortunate fact--they are entirely unpredictable. They can occur in small compressors operating at 50 psig. and in large installations operating at very high pressures. There is no pattern, no way to predict the safety of a particular compressor operation. Such explosions and fires are considered infrequent by some people. In fact, an air compressor operator might go along for years without an accident. However, when they happen, these explosions and fires can blow entire compressor systems apart and even rip yard piping out of the ground. The cost for equipment loss and down time from these accidents can be staggering. Fire-resistant Pydraul AC essentially eliminates the basic cause for most fires and explosions by minimizing the carbon deposits. Its superior oxidation resistance adds to its ability to reduce explosions: by resisting burning in air, Pydraul AC holds the explosion threat to a minimum. TOWOLDMON0035584 PYDRAUL AC GIVES YOU SAFETY AND EFFICIENCY, TOO Compressor operators have kept a close watch on the development of Pydraul AC, seeking the answer to one paramount question: "How well does Pydraul AC lubricate?" With lubricating qualities proven equivalent to those of the highest grade petroleum oil, Pydraul AC has demonstrated its operating efficiency in air compressors of almost every conceivable type. The statement of a lubricating engineer quoted below typifies its reception as a lubricant. The compressor was a Cooper-Bessemer JM-5 located in a large Midwestern plant. "Lubricating properties of Pydraul AC have been very satisfactory. Wear measurements on Molypak rings taken approximately five months later indicate 0.003" wear. This is normal and considered very good. No corrosion of cylinder liners, valves and piping has been experienced, and service is very satisfactory." .........Lubricating Engineer TOWOLDMONOQ35585 COMPARISON PF INDUSTRIAL AIR .COMPRESSOR VALVE DEPOSITS FROM TWO LUBRICANTS Compressor Data: 142 CFM, 6'* LP Sore, 5" HP Bora. S" Stroks, 870 RPM, lOO PSI Air. o TOWOLDMONOQ35586 PYDRAUL AC REDUCES CARBON DEPOSITS The photos on the opposite page compare exhaust valve deposits formed during the 500-hour operation on two lubricants: one, a premium grade petroleum oil, and the other, Pydraul AC. Deposits formed from the 500-hour operation on petroleum oil were removed before the valve began operating on Pydraul AC so the valve was perfectly clean before each operation. A glance at the photo on the left shows that a considerable amount of carbon formed in the normal 500-hour take-down period for petroleum oil. The photo on the right shows the great improvement when the valve operated 500 hours on Pydraul AC. In this particular case, the compressor operator expects to get 7500 to 10,000 hours of service from Pydraul AC without shutting down--a 15- to 20-fold increase of operating time without a shut-down. That's a substantial saving of time and money due to Pydraul AC. TOWOLDMONOQ35587 PYDRAUL AC js CURRENTLY IN USE AS A LUBRICANT IN AIR COMPRESSORS MADE BY t t > '- . :- . ' : ' ' Xtv*ii>1 f:j8' "*S TA/55 MANUFACTURERS, ilti American Messer Corporation r :j Bury Compressor Company ;^ Chicago Pneumatic Tool Company' Clark Brothers Company 1 Cooper-Bessemer Corporation ' De Laval Steam Turbine Company Fuller Company Gardner-Denver Company . V; Ingersoll-Rand Company Joy Manufacturing Company Norwalk Company, Inc. Schramm, Inc. - Worthington Corporation Pydraul AC has been used as an air compressor lubricant for periods up to five years and is now successfully lubricating hundreds of compressors of all types and sizes produced by all of the major compressor manufacturers. Dependable performance is the reason for its wide acceptance. Pydraul AC is being used to lubricate air cylinders in a number of compressors at pressures over 4500 psig. Many compressors have operated continually with exhaust air temperatures of 340J F. Mi TOWOLDMONOQ35588 Extensive field experience has proven that the required lubrication rate with Pydraul AC closely approximates that of petroleum oils. When installing new equipment, it is well to start with an increased lubricant feed rate and reduce by successive increments. Inspection of cylinder walls and valves indicates the proper degree of wetting. On installations converted from petroleum oil to Pydraul AC, the same feed rate as for the petroleum fluid should beadequate. , ^ . \ \ . .'j ; . j; f .; ~ / / \ * V PYDRAUL AC HAS NORMAL USE RATE 03lO^Ob TOWOLDMONOQ35589 CONVERTING TO PYDRAUL AC AS EASY < o The conversion of air compressor systems from petroleum lubricants to fire- and explosion-resistant Pydraul AC is simple, but one procedure is vitally important to insure smooth, efficient operation with Pydraul AC. Exhaust valves and interstage equipment should be thoroughly cleaned before installation, because Pydraul AC will loosen carbonaceous deposits, which may cause unnecessary maintenance down-time and production loss. Once the valves have been thoroughly cleaned of harmful carbon deposits, Pydraul AC keeps them clean--lets you run longer between maintenance shutdowns. standard check for compressors plastic separator bowls Not all plastic separator bowls are suitable for Pydraul AC service because certain plastics are "crazed" or softened when exposed to it. Though separator bowls can be molded of plastics that are totally resistant, for the present it is safest to use glass, brass or steel bowls. If there is a question as to the resistance of a particular plastic, Monsanto will be happy to advise if the material is suitable. diaphragm valves Pydraul AC has a softening effect on the "Neoprene" or Buna N rubber diaphragms that are normally used for petroleum oil service. These rubbers should be replaced with butyl rubber material which is resistant to Pydraul AC. Butyl diaphragm sheeting is available from normal sources of supply. All diaphragms in unloading valves or downstream control valves should be replaced at the time of changeover. Diaphragms in valving downstream from separator systems or drying systems need not be replaced at changeover time, but should be changed on a preventive maintenance schedule as soon as practicable after operation on Pydraul AC is begun. TOWOLDMONOQ35590 special check for splash-lubricated compressors crankcase paint Since the paint used on crankcase interiors of some compressors will in most cases bo softened and eventually removed by Pydraul AC, the paint should bo removed. While the paint particles might pass through the lubricant pump, they could conceivably block the lubricant passages. Therefore, removing this paint is good practice. Standard paint solvents are adequate for removing the paint special check for force-feed lubricators sight-glass fluid If a separate force-feed lubricator of the type normally filled with water and glycerine is used, one of two changes is necessary: either replace the sight-glass fluid with one heavier than Pydraul AC or insert a metal bobber in the sight-glass. Pydraul AC is heavier than water or glycerine and will not rise through these standard sight-glass liquids. "Fluorochemical 101," a clear liquid supplied by the Minnesota Mining and Manufacturing Company, has a higher density than Pydraul AC and is a completely satisfactory replacement. metal bobbers The alternate to using "Fluorochemical 101" is to modify the sight-glass lubricator by inserting a simple metal bobber. The bobber is installed by draining the sight-glass liquid, removing the guide wire and inserting the bobber. Operation of the lubricator is then indicated h.v movement of the bobljor with each stroke of the pump plunger instead of counting the drops as with guide wires. Robbers are available for either McC'ord or Manzell lubricators as McCord part number A2">St9 or Man/ell part number 82-1021-B. Modification of the Madison-Kipp lubricator requires replacement of the entire sight-glass with their number C-CV-300 oil feed indicator. vacuum-sight lubricators Vacuum-sight lubricators require no modification for Pydraul AC usage. QS10408 T TOWOLDMONOQ35591 TOWOLDMONOQ35592 (ft III p K Hi Q. 0 K Q. J 0 E > H Viscosity, (SUS) 50 F. 75 F. 100 F. 130 F. 210 F. Pour point, 0 F. Neutralization number Specific gravity, 60/60 F. Auto-igniting temperature Solubility of water in Pydraul AC 75 F. 210 F. Solubility of Pydraul AC in water 15,000 1,650 410 127 43 20 0.15 maximum 1.35 1,100 F. 0.1 per cent 0.4 per cent Negligible For applications requiring significantly different properties, such as intermittent operation of a portable compressor in areas of low ambient temperature, a fluid similar to Pydraul AC can be provided. Contact Monsanto's Functional Fluids Department for details. Shipping Information Classification, U.S.A. Regulations Standard Containers Chemicals, NOIBN None 55-gallon, nonreturnable, black iron drums, 610 lbs. net. 5-gallon drums, 55 lbs. net. o TOWOLDMONOQ35593 051041 PYDRAUL ACTO ORDER CONTACT THE SALES OFFICE NEAREST YOU For samples or additional information, write Monsanto Chemical Company, Organic Chemicals Division. Functional Fluids Sales, P. O. Box 478, St. Louis 1, Mo. AKRON ATLANTA BOSTON CHICAGO CINCINNATI CLEVELAND DETROIT HOUSTON LOS ANGELES MINNEAPOLIS NEW YORK SAN FRANCISCO SEATTLE WILMINGTON LONDON MELBOURNE MONTREAL TORONTO VANCOUVER 920 BROWN STREET, AKRON 11. OHIO 1-401 PEACHTREE STREET NE. ATLANTA S, GA. EVERETT STATION, BOSTON 49, MASS. 520 N. MICHIGAN AVENUE, CHICAGO 11, ILL. 2330 VICTORY PARKWAY. CINCINNATI 6. OHIO 427 HANNA BUILDING, CLEVELAND 15. OHIO 18230 GRAND RIVER AVE.. DETROIT 23. MICH. 904 CITY NATIONAL BANK BLDG., HOUSTON 2. TEXAS 6670 E. FLOTILLA STREET, LOS ANGELES 22, CALIF. FOSHAY TOWER, ROOM 409. MINNEAPOLIS 2. MINN. 445 PARK AVENUE, NEW YORK 22. N. Y. Ill SUTTER STREET, SAN FRANCISCO 4. CALIF. 911 WESTERN AVENUE, SEATTLE 4, WASH. 4335 GOV. PRINTZ BOULEVARD. WILMINGTON 99. DEL MONSANTO CHEMICALS LTD MONSANTO CHEMICALS (AUSTRALIA) LTD. MONSANTO (CANADA) LTD. Representatives in the Principal Cities of the World. 05 10411 r TOWOLDMONOQ35594 0510411 TOWOLDMONOQ35595 TOWOLDMONOQ35596 \