Document npGx2RVpa0rZdJ5EMQjeZmwgm

Union Carbide Agricultural Products Company, Inc. Institute Plant INDUSTRIAL HYGIENE SAMPLING RESULTS TO: Mr. P- J. Morris COPIES TO: Hr. M. Adkins, Jr. Building 23________________________ Mr. C. R. Thomas Institute Plant___________________ Mr. L. W. Youngblood Purpose: ________ Quarterly ________ Semiannually ________ Annually ________ Regulatory Agency Inspection x Other (See Comments) Sample Date(s): December 19, 1985 Sample Location: MIC-II Unit - Malnt. Comp. 7 Department No.: 327 Process/Activity: Pipe insulation removal Contaminant: Asbestos_______ Exposure Limit: OSHA 2 fibers/cc____________ ACGIH UCC Sample Type: x Personal x Area ______ Source Surface Wipe ______ Other (See comments) Analytical Method: NIOSH 7400 Results: ______ See Comments x See Attached Table COMMENTS: A Maintenance Complex 7 insulator/painter was monitored for exposure to airborne asbestos fibers on the above date. Area concentrations of airborne asbestos fibers were measured too. Monitoring was performed while insulation was being stripped from pipes that were lying on a plastic sheet inside the dike wall that surrounds the old phthalic anhydride tanks at the MIC-II Unit. It was not necessary to wet the insulation as it was being removed because it had become water logged and, at the time of removal, was frozen due to the cold weather. Nevertheless, respirators and protective clothing were worn by the three men performing the work. Since the airborne fiber concentration was unknown at the time of sampling, two sets of samples (having different sample times) were taken to insure that at least one of the sets would produce valid results. All monitoring results were below the lower calibration limit for the analytical UCC 009007 A04022 Union Carbide Agricultural Products Company, Inc. Institute Plant IMDUSTR IAL HYGIENE SAMPLING RESULTS- CONTINUED method, which is well below the OSHA permissible exposure limit. Area concentrations and personal exposures to airborne asbestos fibers were maintained at safe levels during this lob.______________________________________ RECOMMENDATIONS: None___________________________________________ _____________________ Report Date: January 14, 1986 Signed NOTE: Bldg. 2 Room: 172 Phone ALL PERSONAL SAMPLE RESULTS MUST BE DISCUSSED WITH THE PARTICIPATING EMPLOYEE 6105 1335k UCC 009008 Union carbide Agricultural Products Company, Inc. Institute Plant INDUSTRIAL HYGIENE SAMPLING RESULTS WORKPLACE LOCATION: MIC-II Unit, Maint. Comp. 7 SAMPLER'S NAME: E. A. Osby CONTAMINANT: Asbestos____________________ REPORT DATE: January 14, 1986 Sample Number Sample Date W-4409-1 V-4409-4 12-19-85 12-19-85 W-4409-2 V-4409-5 V-4409-3 V-4409-6 12-19-85 12-19-85 12-19-85 12-19-85 Sample Description INSULATOR/PAINTER D. C. Chambers D. C. Chambers Sample Time (min.) 60 18 East side of insulation removal site - 3 feet from activity. 60 16 Northwest side of insulation removal site - 5 feet from activity. 60 15 Sample Results fibers/cc) < 0. < 0. TWA=< 0. < 0. < 0. < 0. < 0. 1335k UCC 009009 A U402'i ENVIRONMENTAL HEALTH LABORATORY 1021 Georgia Ave. / Macon, Georgia 31201 {800) 841-8919 / in GA (912) 745-4702 LABORATORIES IN MACON, GA. AND HARTFORD, CT. LABORATORY ANALYSIS REPORT W To: Account: Location: E. A. Osby Union Carbide Agricultural Products Co., Inc. P. 0. Box 2831 Charleston, WV 25301 Report No.: Purchase Order No.: Date Received: Date Reported: 86A0007 Revised N/A 01-03-86 01-14-86 Analysis: Fiber Count Analytical Method: NI0SH 7400; Phase Contrast Microscopy; Walton-Beckett Reticle; 450 x magnification Sample No (AA) Air Volume (Liters) Fibers, longer than 5 microns, per cc of air. W-4409-1 120 <0.095 W-4409-2 120 <0.095 W-4409-3 120 <0.095 W-4409--4 36 <0.32 W-4409-5 32 <0.36 W-4409-6 29.8 <0.38 cc= Cubic Centimeter. A blank filter was not provided. We recommend that a blank be submitted with each set of samples so that the sampling media can be checked for possible interferences or background contamination. Chemist <( = Less than. Jeanne A. Gibbs AU402b Date:. UCC 009010