Document npGaxvd3OQO48XZ44Nb3O0jQ1

212 . CHAPTER 11 ' '1946 Guide after each of the three absorptions the reduced volume is again measured in the burette. Pressure and temperature of the gas sample are kept constant while measuring. Several passes are made through each pipette which contains tubes or glass beads to increase the wetted surface. It is essential that each reaction be completed before the next reaction is started. Since the life of the reagents is limited, it is well to keep a record of the number of samples tested. Care is needed in operation to prevent the pulling of reagents out of the pipettes into the capillary tubing and burette. Many types of recording gas analyzers are available and are usually found in the larger boiler plants. Carbon Monoxide Measurement . A method of analyzing for low carbon monoxide concentrations com pletes the oxidation of the carbon monoxide in a known volume" of sample, in the presence of a catalyst. The heat resulting is measured by a thermocouple calibrated in parts per 10,000 of carbon monoxide45. SMOKE DENSITY MEASUREMENTS Smoke density may be judged by assigning to it the number of the Ringelmann Smoke Chart which appears to have the same color when Number of Cabo i 2 3 4 Table 1. Ringelmann Smoke Chart Spacings Thickness of Lines, mm 1.0 2.3 3.7 5.5 Distance in Clear7 Between Lines, mm 9.6 7.7 6.3 4.5 s- observed at a distance of 50 ft. The charts are numbered 1 to 4 and are made of black lines cross-ruled on white as given in Table 1. Apparatus using the photo-electric cell has been devised for recording smoke densities in large plants. ' REFERENCES , l--For a comprehensive treatment of temperature measurement the reader is referred to Temperature, Its Measurement and Control in Science and Industry, a symposium sponsored by the American Institute of Physics and published by Reinhold'Publishing Corp. j--Errors in the Measurement of the Temperature of Flue Gases, by P. Nicholls and W. E. Rice (A.S.H.V.E. Transactions, Vol. 35. 1929, p. 473). 1 3--Temperature Measurement (A.S.M.E. Power Test Code, Part 3). --Measuring Heat Transmission in Building Structures and a Heat Transmission Meter, by P. Nicholls (A.S.H.V.E. Transactions, Vol. 30, 1924, p. 94). s--Parallel-Connected Thermocouples for the Testing of Gas Appliances, by Walter B. Kerk-and George J. Pacanovsky (Gas, September, 1939, p. 51). Measurement of Surface Temperatures, by F. C. Houghten and H. T. Olson, Temperature, Its Measurement and Control in Science and industry (Reinhold Publishing Corp.). 7^Standard Test Code for. Centrifugal and Axial Fans, Edition of 1938. See also Standard Code for the Testing of Centrifugal and Disc Fans (A.S.H.V.E. Transactions, Vol. 29, 1923, p. 407; Vol. 37, 1931, p. 363). Instruments and Measurements 21S Illinois Micromanometer (University of Illinois, Engineering Experiment Station Bulletin No. 120. P.91). `, ' " *--The Weathertightness of Rolled Steel Windows, by J. E. Eniswiler and W. C. Randall'(A.S.H.V.E. Transactions, Vol. 34,1928, p. 527). --Pressure Measurement (A .S.M.E. Power Test Code 1936. Part 2. Chapter 2). For technical data refer to Fluid Meter Reports, Parts 1--1937, 2--1931, and 3--1933 (American Society of Mechanical Engineers). 12--Technical Notes No. 546 (National Advisory Committee for Aeronautics, November, 1935). 1J--The Characteristics of Double Pitot Tubes, by F. R. Ingram, E. Diez-Canseco and L. Silverman (A.S.H.V.E. Journal Section, Healing, Piping and Air Conditioning, November, 1942, p. 708). 1Standard Code for Testing and Rating Steam Unit'Heaters (A.S.H.VlE. Transactions, Vol. 36. 1930, p. 165), adapted January. 1930 by A.S.H.V.E. ,5"A.S.H.V.E. Standard Code for Testing and Rating Steam Unit Ventilators (A.S.H.V.E. Transac tions, Vol. 38, 1932, p. 25), adopted June, 1932. 16--Discharge Coefficients of Square Edged Orifices for Measuring the Flow of Air, by H. S. Bean, E. Buckingham and P. S. Murphy (Bureau of Standards Journal of Research, Vol. 2, 1929, p. 561). iJ-A.S.H.V.E. Research Report No. 1140--The Use of Air Velocity Meters, by G. L. Tuve, B. K. Wright. Jr. and L. J. Seigel (A.S.H.V.E. Transactions, Vol. 45, 1939, p. 645). 1*--Flow Measurement by Nozzles and Orifice Plates (A.S.M.E. Power Test Codes, Chapter 4 of Part 5, 19--Temperature. Humidity and Air Motion'Effects in Ventilation, by O. W. Armspach and Margaret Ingels (A.S.H.V.E. Transactions, Vol. 28. 1922, p. 103). " * *6"The Heated Thermometer Anemometer, by C. P. Yaglou (Journal Industrial Hygiene and Toxi cology, Vol. 20, October, 1938, No. 8). 217"A.S.H.V.E. Research Report No. 1165--Development of Instruments for the Study of Air Dis-' tribution in Rooms, by A. P. Kratz, A. E. Hershey and R. B. Engdahl (A.S.H.V.E. Transactions, Vol. 46. 1940, p.351). 22--Development of Testing Apparatus for Thermostats, by D. D. Wile (A.S.H.V.E. Transactions. Vol. 42. 1936. p. 349). . 2#--Linear Hot Wire Anemometer, Its Application to Technical Physics, by L. V. King (Journal Franklin Institute. 1916). - "-A.S.H.V.E. Research Report No. 1204--Entrainment and Jet-Pump Action of Air'Streams, by G. L. Tuve, G. B. Priester and D. K. Wright. Jr. (A.S.H.V.E. Transactions, Vol. 48, 1942, p. 241). 2S--A.S.H.V.E. Research Reports Nos. 857, 911 and 966--Measurement of the Flow of Air Through Registers and Grilles, by L. E. Davies (A.S.H.V.E. Transactions, Vol. 36, 1930, p. 201, Vol. 37, 1931. p. 619, and Vol. 39. 1933, p. 373). "-A.S.H.V.E. Research Report No. 1162--Air Flow Measurements at Intake and Discharge Open ings and Grilles, by G.L. Tuve and D. K. Wright, Jr. (A.S.H.V.E. Transactions, Vol. 46. T940. p. 313). "-A.S.H.V.E. Research Report No. 1092--The Flow of Air Through Exhaust Grilles, by A. M. Greene, Jr. and M. H. Dean (A.S.H.V.E. Transactions, Vol. 44,1938, p. 387). 28--A.S.H.V.E. Research Report No. 936--Investigation of Air Outlets in Class Room Ventilatioh, by G. L. Larson, D. W. Nelson and R. W. Kubasta (A.S.H.V.E. Transactions, Vol. 38, 1932, p. 463). "-A.S.H.V.E. Research Report No. 1076--Air Distribution From Side Wall Outlets, by D. W. Nelson and D. J. Stewart (A.S.H.V.E. Transactions,- Vol. 44,1938, p. 77). 3Measuring Air Flow, by G. L. Tuve (Healing, Piping and Air Conditioning, December, 1941). ai--A.S.H.V.E. Research Report. No. 959--Indices of Air Change and Air Distribution, by F. C. Houghten and J. L. Blackshaw (A.S.H.V.E. Transactions,'Vo1. 39, 1933. p. 261). The Temperature of Evaporation, by Willis H. Carrier (A.S.H.V.E. Transactions, Vol: 24, 1918, P- 25). . 33 Psychrometric Tables for Vapor Pressure. Relative Humidity and Temperatures of the Dew-Point (U. o. Department of Agriculture, Weather Bureau, Washington. D. C.). _ 3.4--A R,ev'j,ev^_0f Existing Psychrometric Data in Relation to Practical Engineering Problems, by W. H. Lamer an,, O. Mackey (A.S.M.ti. Transactions, -January, 1937, p. 33; Discussion A .S.M.E. Transadtons, August. 1937, p. 528). 35--Gas Analysis by Measurement of Thermal Conductivity, by/H. A. Daynes (Cambridge Press, 1933).