Document npBJD4aDQ3Z8zX2VaypNvXYNm

conoco Interoffice Communication To R. D. Gamblin From S. C. Hillman Date November 16, 1983 Subject AFE REQUEST - VCM EXPOSURE REDUCTION Attached is the AFE request for $100,000 for VCM Exposure Reducti project is included in the 1983 Construction Forecast as Item A-10. This This project will reduce employee exposure to vinyl chloride monomer by pro viding contained drain and flush systems for the reactor recovery systems. Provisions will be made so that recovery system equipment can be isolated, water flushed, steam stripped and recovered prior to being opened. Routine dosimetry monitoring over the past two years shows that approximately 29% of the employee overexposures to vinyl chloride result when the operator or mechanic has worked with or in the area of the recovery systems. To reduce the possibility of exposure to VCM while working with recovery equipment the following changes will be made: 1. Replacement of the 2 inch drain lines from the new module knockout pots to the blowdown tank with 4 inch lines to aid in removing PVC chunks from the pots. 2. Installation of isolation valves, bleeders, and drains to the blowdown tank or batch water strippers where they are not already existing so that recovery equipment can be isolated, flushed out, steam stripped and recovered. 3. Replacement of the process water make-up to the knockout pots with utility water flushes. 4. Elimination of several drains in the recovery system that drain to open sewers. No economics are calculated for this safety project. Steve C. Hillman Process Engineer bis Attachments c: JF, CRM, RAF, VEM, CRS, JAD VAB.0001099288 A # AFE REQUEST VCM EXPOSURE REDUCTION 1. The project cost is based on a definitive estimate by the plant. b 2. Money will be committed upon AFE approval. 3. There are no expense items associated with this project. 4. Project completion is estimated to be twelve months after approved. 5. There are no additional operating costs associated with this project. VAB.0001099289 conoco Conoco Inc. Conoco Chemicals Authority for Expenditure Project Title VCM Exposure Reduction Budget Proj. No. A- 1 0 Check if partial AFE AFE No Location 09 Aberdeen O Baltimore Hammond LCCP Newark OKC VCM Project Category \r DuPont Category Requested Capital vi Expense v i. Plant Expansion & Modernization Cost Savings -- Energy Cost Savings -- Other 09 Safety & Health ___________________________________________________ ________________________________________________ _____________ Necessities $ion,poo Product Improvement Pollution Abatement: Water Air Land Miscellaneous Budgeted Capital $96, Q.Q.Q Expense _ Noise Source of Capital Budget Over Commitment Unallocated Transfer Project Description ;; v-.: ': ;V1 . n. ^ - : :P. r J d V* . : : 'L V-- `,.i i**.;'* -7 -V* * .j \ .^ < j : 1' ; - J t- A .: t * \h. i v: .1 ?ll a r j*. * ^ / ;r. i* \ t- Funds are requested to provide adequate .^ i drains, 'bleeders, V JI ,i and isolation valves in the vinyl recovery areas so that recovery system equipment can be flushed out, steam stripped and recove red prior to being opened for maintenance. Also larger drain lines will be ins tailed on the new module knockout pots to reduce plugging of the recirculation system. -A- '! V,-^ V . * p _. = r '"S . I 1 l* \ .1 LUt X _ H 0i. 't -I Jf" 1 ' i'.-'* r| ^ ' "i i'-' t; H r :t' i *t -./V.;;. ?' V* . ^ ? 4*' V:"V.-v: K > tty V: V ^ V if ! '\Si , v-;`V *yf < > I Ai '.IT i a> ' -* I if' ' \. .. . ' 'i 1 v *; ,;= , - ?-V&- ' -l:'! ^ j' ` t . 'V ' i* V'. : : :/ J, L t'.l '3- ^V f .=. . in : * r* tt : I. : - i. - p r ` '`M I% f i .1 * (q b l * ' Vl , / * v't' . b- - - J H. J-. Ii X A .U *'v 'I V-t s I- + *: ..! , rY r r i `: i -F t * : : f\ j* -i :r " rPJ i i f*-' r. f \\ I- r. J . s: . , t: r T. V .; A'' , ft ,,,v JV>T i- I r i- d. 1 1- .4 1 l l*t . . 11., ^ 1 J, ^ " It- . :i: h /r * :3 I ^ ,i . * V . qI T .* V r '.d 'J 'r i* 11 BTT i I*.1*. ^5! Summary of Estimated Cost V . -V, L <1 >4 Other Material Con tin ge ncy Cash and Warehouse Outlay Material j Labor | i _ . :i 56,000 '00 m* t * 1 -r ^ : =. . I- , . 28,000 *. l |00 di' 8,000 | s. / jo 0 Escalation rI l 7. Distribution R. D. Gamb 1 i n 4 Plant (3) Approved By Supt./Mech. Supt 18-103 PA, 11-79 : i J . A. Begley W. H. Harlan B. R. Johnson Total R. F. Wilkinson j i, * - i i 1 1. \ 4 \ | i i 56.0 00 ! 00 Grand Total Date H-n-t * Approved By Manager of Manufacturing r Vice President 8,000 . 100 1 >.. 1 . ! ** * i I H ^^lr ,v>- ' ' 1 ^; -' * qHr , i f| ' ' - : .. i. 111l f -hiI1 ' t' : i, 1 " 4 A . 000 100,000 1-- Date !00 I !oo h> J * * j- i 4 1*'; .1 +? "i . J. : .. ^q ' H .' ' J_ & -f\ Jt ; AFE No. * ."] . .y *\ - ^ `n > - ' - , :* 1 *f 'fM" i " v J'* : *\ L '" ' ' 0m '-*5 r,. ftr i rf V' .^#4 F ^,J.- `.'.f i : rt"-. :? . J. f +r ; conoco Interoffice Communication R. D. Gamblin From : J. C. Greene Date : September 29, 1983 Subject : AFE REQUEST - REMOTE OPERATING VALVES AND INSTRUMENTATION Attached is the AFE request for $130,000 to provide the capability to remotely isolate the VCM storage vessels in the plant. Six new valves with actuators will be installed, and an additional twenty-one actuators will be installed on existing valves. Additional high level and pressure alarms on the sphere will also be provided. This project is item A-9 of the 1983 Construction Forecast. Currently, the VCM sphere and VCM receivers in the reactor area cannot be isolated remotely. Should an emergency occur in one of these VCM storage areas, resulting in a release and/or fire, it would be difficult and hazard ous for personnel to enter the area and manually close the necessary valves to stop the release. This could result in a massive loss of VCM creating an extremely hazardous situation. The VCM storage sphere, the old module VCM receivers, and the new module VCM receivers are the three separate areas for which remote isolation will be provided. One switch for each of these areas will be located in the vinyl control room. Activation of one of the switches will fully isolate all of the VCM storage vessels in the respective area. Interlocks will be provided for the sphere isolation switch to shutdown the VCM sphere transfer pumps and VCM compressors upon isolation of the sphere to prevent the possibility of dead-heading this equipment. Interlock protection between the VCM sphere transfer pumps and the fresh VCM receiver's fill valves in each reactor module already exists. The new valves provided by this project will be fire-safe plug valves. The actuators provided will be air--to--open, fail--closed, spring--return actua tors. Eleven existing actuators* which fail in position upon instrument air failure will be replaced with fail-closed, spring--return actuators. The additional level and pressure instrumentation on the VCM sphere will consist of a new pressure switch and liquid level transmitter. The new instrumenta tion will activate existing alarms in the vinyl control room. No economics were considered for this safety project. A J. C. Greene Process Engineer Attachments c: JF, CRM, RAF, VLT, VEM VAB.0001099291 AFE REQUEST _________ s. REMOTE OPERATING VALVES AND INSTRUMENTATION 1 11 ! 1 ------------------------------- 1. The project cost is based on a definitive estimate by the plant. 2. Money will be committed upon AFE approval. 3. There are no expense items associated with this project. 4. Project completion is estimated to be twelve months after approval. 5. There are no additional operating costs associated with this project. A VAB.0001099292 A Conoco Inc. Conoco Chemicals Authority for Expenditure Project Title Remote Operating Valves And Instrumentation Budget Proj. No. A-9_______ Check if partial AFE AFE No. Location iXj Aberdeen Baltimore Hammond LCCP Newark OKC VCM ______ Project Category DuPont Category: Requested Capital Plant Expansion & Modernization Cost Savings -- Energy Cost Savings -- Other 05 Safety & Health CL Necessities - Safety, Health, ..$1.3Q,.0QQ---------------------------------- Expense Product Improvement Pollution Abatement: Water Air Land Noise Miscellaneous Environmental and Legal Budgeted Capital y 1 30 > 000__________________ Expense _________________________________ Source of Capital Budget--------------------------------------------- Unallocated------------ -------------------------- Transfer Overcommitment Project Description Funds are requested to provide valves and actuators to enable the plant's VCM storage vessels to be remotely isolated in time of emergency. New spring-return, fail-closed actuators are required on each isolation valve of the VCM storage vessels. Additional high level and pressure alarm instrumentation will be pro vided for the VCM storage sphere. Ln Ln * oo oO oo " Summary of Estimated Cost Other Material Field Cost Home Office Cost Sales Tax, Bond, ARI Contingency h Cash and Warehouse Outlay Material . Labor 73,000 1 ,300 100 1 1 1 11 1 1 1 '00 1 J 1 2, 000 13,500 it, 500 j Ii '00 1 100 Joo 11 1 1 Distribution R. D. Gamb1in Plant (3) Approved By Supt./Mech, Supt Pla-Bt Manbger q / j. A. Beg 1ey w. H. Harlan B. R. Johnson R. F. Wi 1kinson I i J i1 .............- Total - 74.300 J- * 1 loo m j Grand Total Date Approved By Manager of Manufacturing Vice President -H----1 --lro2--o 1 130.000 |oo Date 16-103 PA. 11 -79 ^^.0001099293 V 1.2.7 AFE REQUESTS -1984- I I VAB.0001099294