Document np35qjNMzenjgKqaGydZ36Vqm
Monsanto
r.<> .<* 'j, f, Queeny Plant
04* Sept. 21 , 1970
Aroclor Use at JFQ
TO Messrs: P. F. Gatens E. D. Malone E. F. Take B. L. Tllford
F. w. Copanas
D. H. Abresch R. L. Vagner
J A. Stepp c. R. Schrock
R. L. Wiese
D. E. Munie
P. B Hodges
- GO
W, B. Papageorge - GO
D. C. Malm
J. R. Savage
SUMMARY
PCB type Aroclors are used or handled in 4 departments at JFQ. Losses to the plant waste effluent greatly exceed Monsanto's self imposed limitation of 10 ppb and immediate corrective action is required to meet the 12/31/70 deadline for compliance. Every means possible must be taken to prevent these Aroclors from entering our waste effluent or being absorbed in the ground. Tank washings will be sent to the toxic dump and used material will be destroyed by incineration at WGK. The magnitude of volatile losses to the atmosphere will be determined.
INTRODUCTION
Considerable emphasis has been focused recently on
polychlorinated biphenyl losses to the environment. PCB's
are manufactured in the U.S. exclusively by Monsanto Company.
These chemicals are a chief constituent of a series of Monsanto
products marketed under the name Aroclor. Aroclors are used
in a number of other products including paints, paper coatings,
and a number of functional fluids,
.
PCB's are believed to hamper reproduction in birds and act as a low-level poison in the environment. Some are highly resistant to.degradation. Consequently, there is concern over their possible buildup in the environment.
COMPANY CONFIDENTIAL
CONFIDENTIAL
_ EXHIBIT FLf t\joft o f
/*> 8* ' 7
--------------------------------------------- ^ --
.
TRAN 085096
WATER PCB-SD0000005905
Aroclor Use at JFQ
-2-
9/21/70
WHERE AROCLORS ARE USED AT JFQ
Aroclors are used In only four locations at the Queeny Plant. These include:
A. W Building
1. Center section - Aroclor heater 2. Yard - Aroclor heater 3. Leader - Aroclor heater
B. TSC1 Department
1. Aroclor heater for the old ortho column reboiler. 2. Aroclor heater for the new detoluene still reboiler. 3. Aroclor seal fluid for the Nash compressor on the
HC1 recovery system.
C. Phthalyl Chloride
1, Combination reactor heating and cooling system.
D. Central Drumming
Aroclors 1232. 1242, 1248, and 5442 are used as raw materials in numerous blended products.
The following is a list of current products containing Aroclors.
Product Number
Product Name
Aroclor Used
80401 80404 . 80405 80406 80409 80413 80422 80448 80458 80467 80474
80475
COMPANY
CONFIDENTIAL.
Pydraul - 625 Pydraul - AC
Pydraul - F-9 Pydraul - 150
Pydraul - 979 Pydraul - 230 Santosafe 300
MGS 153 Pydraul - 320
Pydraul - 312 Pydraul - 135 Pydraul - 540
5442
5442 1248 1242 1232
1232 - 1242 1242 - 1248
1232 - 1242 1242 - 1248 1242 1232 - 1242 - 1248 1242 - 1248 - 5442
CONFIDENTIAL
IR*N 0850,7
WATER PCB-SD0000005906
-3-
Aroclor Use at JFQ
9/21/70
DISCUSSION OF AROCLOR USE
The W Building has three Aroclor heater systems all of which are using Aroclor 1248. The small homemade unit located in the center section of the building is no longer used except as a backup system on rare occassions. It is expected to be dismantled for safety reasons in. the near future. The system known as the "yard unit" is a 1 51 BTU unit located south of the X Building. This particular unit was said to have an excellent maintenance record. Addition of makeup Aroclor to this system is extremely rare.
The principle source of Aroclor loss from the W Building is the "leader unit". This is a 3 M BTU unit located south of the BBB Building. This unit has a bad history of losses. Considerable difficulty has been experienced with pump seal3 in the system. Last year the pump seals failed five times which resulted in the 1033 of approximately 800 gallons of Aroclor 1248. After the last failure a filter was installed on the pump lubricating line in an effort to prolong the
seal life.
Precautionary measures are taken in the department during
changeover to insure against losses. Equipment is drained
to cans and the Aroclor is returned to the system whenever
possible. If contaminants were present, the material was
drummed for toxic dump disposal.
.
The TSC1 Department also has two Aroclor heating systems. There is an old system on the ortho column reboiler which was Aroclor 1248. There i3 also a system for the detoluene
31ill reboiler using Aroclor 1248. These systems are normally very tight requiring makeup very infrequently. One incident of Aroclor contamination by T3C1 occurred this year after one of the heat exchangers was rodded out. At that time a con
siderable amount of 1248 was disposed of due to contamination. The method of disposal was not definitely determined. However, indications are that it wa3 probably 3ewered.
COMPANY CONFIDENTIAL
TRAN 085098
WATER PCB-SD0000005907
Aroclor Use at JFQ
9/21/70
DISCUSSIONS OF AROCLCR USE
Aroclor 1232 is used as the seal fluid for a Nash compressor in the HC1 recovery system. This system seems to be a constant source of losses. Aroclor tends to buildup regularly in a portion of the systems' instrumentation. This buildup requires periodic drainage. The Aroclor is drained to a pump catchpan which goes to the sewer. Estimated losses from the TSC1 department year-to-date are 4,400 lbs. of A-1232 and 1,800 lbs. of A-1248.
Tfte Phthalyl Chloride Department has one Aroclor 1248 system which is used for both heating and cooling of a reactor. Heating is accomplished by the use of bayonet heaters directly in the reactor Jacket. The Aroclor is circulated through an external heat exchanger for cooling of the reactor. Losses are about 1000 lbs./yr.
The procedures and precautions taken to prevent losses at CLHS are considered to be Inadequate for the handling of all products including Aroclors. Considerable improvement particularly in the handling of Aroclors is required immediately. Considerable spillage occurs when handling Aroclors from tank trucks. Much less occurs when using tank cars but despite requests tank cars are not always available. Blend tanks are not washed at the conclusion of operations and succeeding blends are contaminated with small quantities of Aroclors. The magnitude of the loss from this department to the city sewer is unknown. No satisfactory means of sampling the waste effluent has as yet been devised.
In'general Aroclors numbered up through 1242 are considered
at least partially degradable and are not as serious a
longterm environmental hazard as others. Aroclors 1254,
1260, and 1262 are, very undesirable.
'
COMPANY CONFIDENTIAL
TRAN 085099
WATER PCB-SD0000005908
t
-5-
Aroclor Use at JFQ
9/21/70
Use of 1254 and 1260 in our plant has been terminated. A substitute v/hich is not considered a "bad actor", Aroclor 5442, i3 now being used. Aroclor 1248 is not one of the worst Aroclors but it is worthy of considerable concern.
SAMPLED SEWER LOSSES
Ten day continuous composite samples were taken on the north and south trunk sewers for Aroclor analysis in early June. These samples indicate the losses from the W Building and TSC1, Fhthalyl Chloride Departments respectively, during this period. Results of these analyses and the theoretical average losses based on annual Aroclor consumption are as vfollows:
Component Sample
North trunk sewer South trunk sewer
PCB (ppb)
46.5
147.0
Measured__________________ Theoretical____ .
Flow Loss
PCB Loss
(spn) (lbs./day) (PPb)
(lbs./day)
554 0.31
3867
25.7
2460
4.34
1244
36.7
The extremely large difference between the theoretical and measured losses may in part result from sampling errors. Since Aroclors have a high specific gravity, it is possible that the sample is not representative and that only the
soluble portion is being detected.
COMPANY CONFIDENTIAL
CONFIDENTIAL
TRAN 085100
WATER PCB-SD0000005909
-6-
Aroclor Use at JFQ
9/21/70
SAMPLED SEVER LOSSES
Monthly oomposlte samples of the main sewer effluent are being taken. The results of these analyses are:
Month
PCB
Plow
Loss
PFB 0PM Lb s./Day
June July
46 43.5
4338 4621
2.40 2.41
DISCUSSION
According to Paul Hodges, the tentative maximum PCB limit
''(set by Monsanto) for our waste effluent is 10 ppb. This level is to be reaced by 12/31/70. Our losses currently are as large as experienced at manufacturing 3ites. Immediate steps are required if we are to meet requirements by the deadling.
ACTIONS REQUIRED
The following actions are required to reduce losses to targeted level by 12/31/70. Production and PC&D have the overall responsibility that required actions are taken. TSD has the responsibility for providing assistance as
required.
1. Every effort must be made to prevent even the smallest drip from entering our waste effluent or being absorbed in the ground. Drip pans, containers, and curbing must be provided at all locations where a potential loss can occur.
Responsibility: .
J. Stepp, D. Abresch, C. Schrock, R. Wagner for their respective departments with assistance from
TSD.
Completion Date: 12/31/70
COMPANY CONFIDENTIAL
CONFIDENTIAL
TRAN 085101
WATER PCB-SD0000005910
Aroclor Use at JFQ
-7-
9/21/70
ACTIONS REQUIRED - (continued)
2. Contact of Aroclor with water is to be avoided
wherever possible since the material is soluble
in the 50-300 ppb range depending upon the specific
Aroclor involved,
Responsibility: '
J. Stepp, D. Abresch, C. Schrock,
R. Wagner, with assistance from TSD as required.
Completion Date: 12/31/70
3. Blend tanks at CLHS should be washed at end of a
"
run and all tank washings containing Arocldrs must
be sent to the toxic dump.
Responsibility: PC&D
Completion Date: 10/31/70
4. Aroclors which are no longer usable are to be sent to WGK for disposal. They are to be clearly marked "Aroclor For Incineration".
Responsibility:
Production
.
Completion Date: Immediate
5. Operating Instructions are to be revised immediately and operating and'maintenance people instructed in the proper handling and disposition methods for Aroclors.
Responsibility: production, PC&D
. Completion Date: Immediate
COMPANY CONFIDENTIAL
CONFIDENTIAL
TRAN 085102
WATER PCB-SD0000005911
Aroclor Use at JFQ
9/21/70
FUTURE WORK
1. Sample sewer from CLHS and determine magnitude of loss by 10/31/70.
2. Provide monthly composite samples of plant waste effluent for PCB analysis.
3. Follow up monthly to see that necessary corrective measures are taken.
4. Determine magnitude of volatile PCB losses to the atmosphere by 10/31/70.
R. C. Neal Peterson
/nz
COMPANY CONFIDENTIAL
TRAN 0*5103
WATER PCB-SD0000005912