MATERIAL SAFETY DATA SHEET Jm e I. 2006
Group MtSTRON PLUS*
LU ZEN AC A M E R IC A INC. 345 Inverness Drive South C entennial. C O 80112 1 800 325 0 2 99 (General Information)
MEDICAL EMERGENCY ^ FO R M ATIO N Contact: 1-303-623-5716 (24 hr.)
Rocky Mountain Poison Control C enter
SEC TIO N 1 - S U B S T A N C E IN FO R M ATIO N
SUBSTAN C E: Talc
M O LE CU LAR F O R M U L A 3 M g 0 *4 S i0 2'H J0
C H EM IC AL F AM ILY: Silicate
PR OO UC T and TR AD EN AM ES : The d a ta contained herein applies lo Luzenac A m enca talc products bearing the k n o w in g nam es:
MISTRON PLUS SECTION 2 - COMPONENTS
|
M A JO R : Talc a hydrous m agnesium s ic a le : C AS # 1 48 07 -96 6 CON C EN TRATION : '9 8-10 0%
M IN O R : Dokymte a m agnesium calcium carbonate; C A S #16389-88-1 N on H azardous Additives
<2% <1%
SECTIO N 3 - EXPO SURE LIM ITS
|
TALC
OSHA 20 mppcl PELTWA AC G IH 2 mgiYn1 TLV T W A (respeaWe dusl)
S E C T IO N 4 - FIRE , EX P LO S IO N & R E A C T IV IT Y
~|
FIRE AND EXPLOSION H A2ARD: None R EAC TIV ITY: Stable
RRE FKSHRNG M E D IA None INCOMPATTBILmES: None
FLASH POINT: None DECOMPOSITION: None hazardous
[ SECTIO N 5 - TO XICITY
TALC
NIOSH R e g is try N um ber: W W 2710000
SAX T o x ic ity E va lua tion THR: Not available
C arcinogenic Status:
IA R C C ancer Review. H um an Inadequate Evidence
IARC Cancer Review: Am m ai inadequate Evidence
IARC: Not classifiable as a hum an carcinogen (Group 3)
O SHA: N ot l-sted
ACGIH: A4 - Not Classifiable as a Human Carcinogen
N IP : Not listed A 2-year inhalation study dem onstrated d e a r evidence of carcinogenic activity in
female rats at
x p osuro levels o M 8 rngm S. Som e evidence o f carcinogenic activity w as observed n m ale rats at th e sam e level. No evidence o l
c a ro n o g e n c activity w es found in m ic e (NTP T R-421).
T u m o rtg e n lc Data
TCLo: iN-rat 11 mg'm a'IYI
TDLo: im p rat 200 m gVg
O th e r T o x ic ity Data:
S kin a nd E ye Irritation D a ta - skn hmn 300 u g G D I MLD
T e ra to g e n ic ity ( R e p ro d u c tiv e E f fe c t * D ata): N ot available.
M u ta tio n D ata: Not available.
S E C T IO N 6 - H E A LT H E F F E C T S A N D F IR ST AID
INHALATIO N
AC U TE EXPOSURE Exposure lo a large concentration o l ay-b om d u s l of this m aterial m ay cau se mechanical irritation o f th e m ucous m em bran es and respiratory tract.
Version 10.0 - Revised 11/21/2006
Page 2 of 4
MATERIAL SAFETY DATA SHEET Juno 1,2006
Group MISTRON PLUS*
C H RO NIC EXPOSURE: Repeated or prolonged inhalation o i air bom dust o f to s m atenal m ay cause scarring ol the lungs (pulm onary Itoross), w *h shortness o l breath, chrome cough, and respiratory assisted heart fature. Prolonged exposure to talc can produce sym ptomatic late pneum ocom oss.
FIR ST AJO: Rem ove from exposure area to Iresh air. If breathing has stopped, perform a rtifo a l re s p ra to n and get m ertcal attention immerJatery Keep person warm and at rest Treat sym ptomatically and supportively.
* SIGN CONTACT
ACUTE EXPOSURE: Direct contact m ay cause dryness, or m ay cause m * j n a tio n il an a ile rg c predisposition exists.
CHRONIC E XPOSURE: Prolonged contact m ay cause dryness d th e skin, or m ay cause m id irritation if an altergc pre-dispostion exists
FIR ST AJO: A pply com m on ston moisturizers to relieve dryness. Irritations are uncom m on; however, it irrta to n o r redness develops, seek m edical attention. Broken stun can be cleansed w ith m ild soa p and water.
* EYE CONTACT
AC U TF E XPOSURE: Direct contact w ith dust m ay cause mechanical imtabon ol too eyes.
CHRONIC E XPOSUR F: Repealed exposure m ay cau se conjunctivae i nfla m m aion. R R S T AID: W ash e yes w th targe am ounts o l w ater or normal sakne solution. Uirrttaten o r redness develops, seek m ed cal attention.
- IN G E S T IO N ACUTE E XPOSURE: This m aterial is consxfered lo b e harmless and inert w hen ingested.
CHRONIC E XPOSURE: R epealed ingestion o l large doses ot talc lor 13 a nd 10 successive days b y ra b b is and mice, revealed negative teratogenic and c a ro n o g e n c resiAs. FIR ST A ID ; Treat symptomabcany and s u v m ty , |i y o o tfn g vr, keep head tower th an hips to prevent a sp ra to n
S E C TIO N 7 - P H Y S IC A L D A T A
~
TALC
DESCRIPTION: A natural m ne ra l; grayish-vrttfe powder w ith a slight earthy odor. p H : Sfcghtly basic
DECOMPOSITION TEMPERATURE: 1652*-1832F (900* 1 0 0 0 *0
S P E C F IC G RAVITY (water = 1.0): 2.8
S O LU B IL IT Y W a te r <1 m g fm l @ 21 C (RAD) E thanol: <1 m gTm l @ 21 C (RAO) Acetone : <1 m g /m l @>21 C (RAD) C old acids: Insoluble A lk a le s : Insoluble
| S E C TIO N 8 - STO R A G E, D IS P O S A L t E N VIR O N M EN TAL
S TO R A G E: Preserve in seated containers to prevent drapersen o l dust in air.
W ASTE D ISPO SAL: D ry material c an b e land l i e d Observe all federal, state and local regulations. Ke spo nstxlty tor proper waste disposal is w ith the owner ot the waste
CONDmONS TO AVOtO: Prevent d s p e rs o n of dust in air.
A C C ID EN T AL S P ILLS : For large spills, shovel or sweep up (while keeping d s p e rs a n c t dust in air lo a m n m u n ) and place n to su ta b ie sealed containers for reclamation or later disposal Residue should be cleaned up using a h g h-e ffo en cy particulate W er vacuum . The use o l w ater wash-down s not recomm ended W et m aterial can cause a surface used lor w akin g to become extremely slippery.
Version 10.0 - R evised 11/21/2006
PLAINTIFFS EXHIBIT
CAM-170
Page 3 Ol 4
M A T E R IA L S A F E T Y D A T A SHEET June 1.2006
Group MtSTRON P LU S *
SECTION 313 SUPPLIER NOTIFICATIO N: This product does not contain to xic chem icals subject to the reporting requirem ents ot section 313 o t the Em ergency Planrxng a n d Com m unity Right-To-Know Act ot 1986 and ot 4 0 C FR 372.
R C A A : Talc is not considered a hazardous w aste by RCRA criteria (40 C F R 261). State a nd Local regulations restnetons am com plex and m ay cider from Federal regulations.
SEC TIO N 9 - P R O TE C TIV E EQ UIPM EN T
V E K H LA T IO N : Provide local exhaust o r process enclosure ventilation to m eet published exposure im ts .
RESPIR ATOR : I he to llo w n g m axim um -use concentrations and respirators are recomm endations by the U S. Departm ent ot Health and H um an Services; N IOSH Pocket Guide to C hemical Hazards; or b y th e U .S. Departm ent o t Labor. 29 C FR 1910 subpart Z.
Tate M a x im i/n U s e Concentration____ Q j j f l t a i g i 10 m giYn.....................................................-A n y dust and m e t respirator. 20 rngmi*............................................. .........A n y dust and m ist respirator except single use and quarter-m ask respirators
G L O V E S : Protective gloves are not requxed. bu t m ay be worn to prevent stun dryness o r irrita fen due to stun allergy.
EYE PR OTECTIO N: Employees should vw ar dust resistant safety g o r fe s to prevent eye contact with high concentrations ot ax bom dust of this scAetance W here there is a possAxlity that an em ployee's eyes m ay be exposed to b u k qu a n tile s or high concentrations o t air bom dust ot this substance, the em ployer should provide an eye w ash VxxXain withm the im m e da te w ork area lo r em ergency use.
S E C T IO N 10 - A D D IT IO N A L IN F O R M A T IO N
NPCA
National Paint and Coafcngs Association - y az a rd x x s M aterial identification System (HMIS) HEALTH H AZARD: 1* sig h t FLAMM ABILITY H AZARD: 0 rrxnimN PHYSIC AL HAZARD: 0 - m toimal PERSONAL PROTECTIO N: E - glasses, gloves, dust respirator
C ER C LA RATINGS: (Scale 0-3) Health - 0. Fxe - 0. Reactivity - 0 , Persistence - 3
NFPA RATINGS: (S c^ e 0 4) H ea th . 0. Fire - 0. Reactrviy - 0
U.S. D EPAR TM EN T O F TR AN SPO RTATIO N - D OT: No classification a s s g ne d
CANADIAN TRANSPORTATION OF DANGEROUS GOODS No dassrtcahon assgned
LAND TRANSPORT ADfVRlD No dassificalon assgned
AIR TR AN SPO R T - 1ATATCAO: No d a ssrfcatO n as s g ne d
M AR ITIM E T R AN SPO RT IMDG N o d a s sificato ns assg ne d
H AR M O N IZED T A R E F C ODE. Talc crushed or po w de re d 2S26 20.00. (Slat. Suffix 00)
EP A T SC A STATU S: Osted (CAS 14807 9 6 6)
E P A TSC A 12(B) EXPORT N OTIFIC ATIO N: Not listed
C E P A D O M ESTIC S UBSTANCE U S T - D SL STA TU S Listed
C E P A N ON-DOMEST)C SU BSTAN C E U S T - N D S l S TATUS N ot listed
OTHER INVENTORES: A IC S (Australian) EINECS (European No: 238 877-9) ECL (Korean No: K E -32773) SW ISS (Giftliste No: G 6839) PICCS (PNfcppines) MIT1 (Japan) Not listed - (not required lor natural m nerals)
C ALIF O R N IA P ROP 65 S TATU S: Talc not listed
Verson 10.0 - Revised 11/21/2006
Pago 4 d 4
MATERIAL SAFETY DATA SHEET Juno 1,2006
Group MISTRON PLUS*
STA TE RIG HT-TO-KMOW . Talc listed Btoxw: Massachusetts; N ew Jersey; Pennsytvana; Florida
C LE A N AJR A C T - O ZONE D EPLETIN G C H EM IC ALS (OOC*s): None
CONEG APPROVED P A CK AG NG Yes
U 5 - FDA CITATIONS:
21CFR 178.3297 21CFR 175.300 21CFR 175.380 21 C F R 175.390 21CFR 176.170 21C F R 177.1210 21 C F R 177.1350 21 C F R 177.1460 21CFR 73.1550
W3CLAMEfl
Luzenac A/nanca. Inc fxow Jci the mtormation contamed he*e>n m good la in bol make* no repe*crtton as to it comp<eh*nvveci or
accuracy Ths document is tended only as a gude to me appropriate precautionary nam ing of the maieoK by a property traned peraon u*ng th s product Indtvtduals receiving the nkymehon mutt eiercoe r e * independent judgment n oelernieimg its appropriateness tor a particular
purpose LUZENAC AMERICA. INC MAKES NO REPRESENTATIONS OR WARRANTIES EITHER EXPRESS OR IMPLCD. INCLUDING WITHOUT IMITATIO N ANY WARRANTIES OF MERCHANTABILITY. FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE
INFORMATION SET FORTH HEREIN OR THE PROOUCT TO WHICH THE INFORMATION REFERS ACCORDINGLY. LUZENAC AMERICA. INC WILL NOT BE RESPONSIBLE FOR DAMAGES RESULTHO FROM USE OF OR RELIANCE UPON THIS INFORMATION_______________
ISSUED BY:
F W w d J 7azens)u Ftegtfatory Affairs Manager Luzenac America. Inc. Phone: 1 303 643 0404
END OF MSOS GROUP - MtSTRON P LUS*