American Society of Heating and Ventilating Engineers Guide, 1924-25 TABLE 64. SIZE OF PLAIN AND HYDRO-PNEUMATIC TANKS Compensation Lb. per Hr. 4000 6000 8000 10,000 16,000 24,000 34,000 45,000 60,000 Subs of Plain and Hydro-Pneumatic Tanks For Air Separator only Diameter In. Length In. For Air'Separator and Water Storage Diameter In. Length In. 12 24 . 24 36 12 36 24 48 18 30 24 72 18 48 30 48 24 48 30 60 30 48 36 60 . 24 72 36 72 36 60 36 96 36 72 42 72 42 60 42 96 36 96 42 72 48 72 42 96 48 96 Receivers.--The receiving tank capacity should be stated in gallons, and in case of automatically controlled units should be the capacity, of the tank in gallons between the high and low water levels in this tank, as determined by the water line control. The receiving tank may be placed either on the suction side or on the discharge side of the pump. When placed on the suction side of the pump the capacity of the tank may be used to retain the condensation and to take care of the fluctuations between the rate of condensate returned and the rate of the pump de livery. The suggested receiving tank capacities (as previously defined) for continuously operated and for automatically controlled units are as follows: TABLE 65. RECEIVER TANK CAPACITIES So. Ft. Equivalent Direct Cast Iron Radiation Surface Total Receiver Tank Capacity in Gallons Receiver Tank Capacity between High and Low Water Limits where Automatic Water Line Control is Used. 8,000 16,000 26,000 40,000 65,000 100,000 28 33 40 49 63 80 20 24 29 35 47 63 Air Capacities.--The air capacities recommended, refer to cubic feet of air per 1000 sq. ft. of equivalent cast iron direct radiation, may be assumed on a decreasing ratio as the system increases in capacity of equivalent square feet of radiation, in accordance with the Table 66. It should be noted that while water capacities of pumps to be added for fan blast heaters are to be based upon their equivalent in direct radiation 84 American Society of Heating and Ventilating Engineers Guide, 1924-25 the air capacities for this class of radiation may be the same as for direct radiation. TABLE 66. AIR CAPACITIES Sq. Ft. Direct Equivalent Radiation Surface 8,000 16,000 26,000 40,000 65,000 100,000 150,000 250,000 Diameter Orifice Vac. 10' A' A" 14' A* %' w A" Three }' Air Capacity Cu. Ft. per Min. 5 9 15 19 34 60 80 180 The air capacity of the pump should be measured at a point in the main vacuum return line just ahead of the vacuum strainer when the pump is operating under the vacuum specified at the pump suction and when handling the quantity of condensate specified at a temperature not exceeding 180 deg. fahr. Air test may be made with water at lower temperatures. This determination should be made by means of a stand ard test orifice located in an inlet connection to the pump suction and consisting of a plate ]/s in. thick with a reamed hole having sharp edges and of a diameter corresponding to the capacity of the pump. * Fig. 21 may be used to give the quantity of air handled, corresponding to several sizes of orifices and different degrees of vacuum met with in practice. Size A B C D E F G H TABLE 67. ONE PUMP ONE MOTOR RETURN LINE SYSTEM Sq. Ft. Direct Equivalent Radiation Surface Diameter Orifice Vacuum 10 In. Air Capacity Cu. Ft. per Min. 8000 16,000 26,000 40,000 65,000 100,000 150,000 250,000 9-64 3-16 1-4 9-32 3-8 1-2 9-16 Three 1-2 6 11 19 25 42 75 90 180 Water Capacity Gals, per Min. 10 Lb. Pres sure ISO*4 F. u 22 35 60 90 140 200 400 Actual H. P. 0.9 1.4 2.0 2.8 3.9 9.0 10.0 10.0' R. P. M. H. P. of Motor 1800 1800 1800 1200 1200 1200 900 720 1 m 2 3 5 10 10 20 Water Capacity.--The water capacity of the pump when operating against 8 in. of mercury vacuum should be not less than two-thirds of a pound of water per hour pier square foot of equivalent cast iron direct radiation based upon condensation at a temperature of not over 180 deg. fahr. when the pump is delivering water against a specified gage pressure at the water discharge of the pump. For pumps handling both air and water the above water capacity must be delivered, when the 85