Document nmpbdmyLdebByLa5E914bMOmz
Monsanto industrial chemicals co.
R. E. Keller - TIB"*OM i NAME. & LOCATION)
o*te : September 30, 1975
SUBJECT
CHLORINATED DIBENZOFURANS IN PCBs
WBP 6/13/75 memo to REK et al
TO : W. B. Papageorge B2SK
cc S>^Bergen - B2SL
Mieure - T2F
R. H. Munch - TIB
C. Paton
- B2SC
R. G. Potter - B3SA
W. R. Richard - T3A
D. Wood .
- B2SD
P. L. Wright - A2SC
s memo summarizes_progress~~QTf'the action plan covered by the reference
io. All items beTow were targeted tor completion by October 1.
'' "
____ ___
.1 Arrange for the preparation of the required furan standards.
The following laboratory mixtures were prepared by Q. E. Thompson:
(a) Mono-, di- and tri-chlorinated dibenzofurans; (b) Tri- and tetra-chlorinated dibenzofurans; (c) Penta-, hexa- and hepta'-chlorinated dibenzofurans.
These mixtures have been characterized for the homologue composition by GC and GC/MS.
Small quantities of the above mixtures were sent to R. Lidgett at Louvain-La-Neuve on 9-15-75 for method development work related to pentachlorophenol.
Refine analytical methodolgy to achieve detection levels of at least 0.1 ppm for each furan homologue.
Our earlier methodology permits measurement of each chlorinated dibenzofuran isomer in PCB products as follows.
Detection Limit
Tetra- through Hexachlorodibenzofurans
0.5 ppm (each component)
Mono- through TriChlorinated Dibenzofuran
Unknown (>10 ppm)
The goal for the above action was to develop a method with detection limit of 0.1 ppm for each of the above components.
We have developed methodology over the past two months which is beTTeved to have the necessary detection limit of 0.1 ppm for tetrathrough hexachlorodibenzofurans. However, we have been unable to validate this~detectton limit because we find about 1 ppm total for those isomers in Aroclor 1254. We haitp heen unable to develop improved methodology for measurement of mono- through tri-chiorinated dibenzofuran in Aroclor 1016 after several man months of effort. We have'TouncPthat methodology reported by the FDA for these measurements cannot^eTep^roduced"Th our laboratories': We"have sevefaTmore analytical schemes to try to resolve the above problems.
oS,N3l*s6
IN - 10 REV, 1 '72
STLCOPCB4055663
W. B. Papageorge -2- September 30, 1975
3. Arrange with outside laboratory to confirm accuracy and reproducibility of methodology.
No action on this since results have not been obtained yet for item 2 above.
4. Arrange with P. J. Marsh and R. A. Baxter for discussion with Bayer for possible mutual exchange of information relating-to furan analyses.
Contacts have been made with Monsanto-Europe. Most recent memo reply to REK from R. A. Baxter on 8-19-75 indicates that there will likely not be any information of significance coming from Bayer or Predelec.
5. Analyze Aroclor products produced at Sauget and Newport. Samples to include currently produced material as well as material produced prior to 1970.
Materials have been received from both plants. Samples are being held until completion of item 2 above.
Overall, we have not vet achieved the total capabilities needed for deter
mination of 0.1 ppm chlorinated dibenzofurans in PCB products. It is our~
<understcrrnti ng that Justin can on for continuing this analytical research
is based on showing that the level of chlorinated dibenzofurans is below
toxicological significance (<0.1 ppm). Even though the odds of success
are not high, we plan to continue with one additional man month of effort
on this project. Recipients are asked to advise us it^they are not in
agreement.
R. E. Keller ss
DSW 318487 STLCOPCB4055664