Document nmpE522w0XwXjDr41VKOKawbw
Delco'Frigidaire
Air Conditioning, Automatic Heating Systems
DELCO OIL BURNER SPECIFICATIONS (based on 110 Volts--60 Cycle AC)
Model
Gallons OD Per Hour
Maximum Capacity-Total Tax (Boiler or Furnace Output) Btu S. H.W.
Motor Hp Watts Rpm
DR1 1.0-1.35 105,600 440 700 1/8 S-P 135 1740
DR 1.35-2.75 216,000 900 1,440 1/8 S-P 135 1740
DI2 2.5-7.0
559,200 2,330 3,725 1/6 S-P 160 1735
D34 7.0-16.5 1,2%,000 5,400 8,600 1/3 R-l 415 1750
D44 15.0-30.0 2,880,000 12,000 19,200 3/4 R-I 760 1750
Models available for operation on other cycles, 220 Volts and DC.
Lift
8'0* 8'0* 8'0* 13'(P 13'CT
Pump
Pounds Weight
Gal Strainer Per Area Net Hour Sq In.
Ship.
13 17
100 132
13 17
100 132
13 36
115 158
90 49.5 298 385
90 49.5 383 532
DELCO OIL FURNACE SPECIFICATIONS
Model
Capacity Total Tax Net
Gal Oil Per Hour
Btu Per Hour Output
S HW S HW
Overall Dimensions Lgth. Width Height
Htg. Surf. Sq ft
Cu ft Firebox Volume
Height Water Line Steam
Water Heater
Circu lator Model
Flow Vjve
DM3 400 640 285 455 1.0 DH3 625 1000 485 765 1.65 DH4 1050 1675 800 1290 2.5
96,000 38'/,' 26'/,' 51 Vi* 29
2.9
150,000.
33'/,' 54Va' 55.25 4.3
252,000 36*/ 33'/,' 54'/,' 80.0 6.5
443/4* 2A* 46'// X* 46'// X*
15* 15* 22*
120* 120* 125*
meDU 1400 2200 1080 1700 3.5 336,000 62s/a- 33'// 55'// 104.75 8.7 46'// X 22 125
DL6 1725 2750 1335 2140 4.5 414,000
33'/,' 55'/.' 129.5 10.75 46'/,' 2D 22 125
*Not Standard Equipment.
DELCO GAS FURNACE SPECIFICATIONS
Model
Capacity
A.C.A. Btu
Total Tax
Net
Input Output Per Hour
S HW S HW Btu 80% Eff.
Overall Dimensions
Htg.
Lgth.
width Height
Surf. Sq ft
Cu ft Firebox Volume
Height Water Line Steam
Water Heater
Circu lator Model
Flow Valve
GH3 625 1000 485 765 187.000 150.000 4234' 33'/,' 54'// 55.25 4.3 46/,' X* 15* 120* GH4 1050 1675 800 1290 315.000 252.000 54V/ 33'/,' 54'/a' 80.00 6.5 46/,' X* 22* 125* Not Standard Equipment.
DELCO OIL FIRED CONDITIONAIR SPECIFICATIONS
Hourly Btu Ratings
Blower
Burner
Max. Btu Output at Plenum Net Btu Output at Registers Max. Cfm Delivery
Model
Unit Fan No. Rpm
d
2
Size
Motor
Model
Hp
Rpm
Watts o.S
Net Wt.
Hp Rpm Watts
3
DA-0 100,000 85,000 1 400- 1600 660
2
*
N
1/4 S-P 1725
210 DRO 1/8 S-P 1740 \
135
8' 801.
DA-1 135,000 115,000 1 400- 1600 2 * 1/4 S-P 1725 210 DRF 1/8 S-P 1740 135 8' 960 660 w\
DA-2 200,000 170,000 2 400- 2400 4 K 1/4 S-P 1725 250 DF 1/8 S-P 1740 150 8' 1435
660
DA-3 325.000 280,000 2 335- 4000 9
3/4 TC 1710 780 DF-2 1/6 S-P 1740 150 !(/ 2000
590
DELCO GAS CONDITIONAIR SPECIFICATIONS
Htg. Surface
Sq ft
Com. Chamber
Vol. Cu ft
Input Mode) Btu Per
Hour
Output Btu Per
Hour
Registers Btu Per
Hour
Max. Cfm
Cabinet Dimensions Width Lgth Hght
Duct Openings Return Warm Air
Ceding Height Min.
meGAO 133,000 100,000 85,000 1600 70 5.5 30* 54'/,' 46y,' 21' x 25V/
* 27'/,' 6'0*
GA1 181,000 135,000 115,000 1600 82 6.4 31'/,' 48' 50* 14' x 28' 18' x 28'
6'0*
GA2 267,000 200,000 170,000 2400 112 10,0 33' 64V,' 50* 14'x46' 18' x 46'
6'0'
GA3 400,000 300,000 255,000 4000 159 23.4 70* 86' 55* 24'x 62* 26' x 62*
6'6'
892
Air Conditioning, Automatic Heating Systems
The Fox Furnace Company
Elyria, Ohio
Division of American Radiator and Standard Sanitary Corporation
Sales Offices:
Cleveland, Ouro New York, N. Y. Boston, Mass. San Francisco, Calip.
SUNBEAM
AIR CONDmONINO
Jobbers in principal cities. Engineering layouts provided by
factory
Sunbeam Oil Fired Air Conditioning Units
Series Nos. 200 and 600
Like gas and coal fired Sunbeam Units
shown herein, this series is designed to air con
dition residences and small stores, churches
and other buildings. Each Air Conditioner
heats, filters, humidifies and circulates the air
in winter and provides circulation of filtered
air in summer. Mechanical cooling can be
added.
Exterior Cabinet--No. 20 gauge furniture
steel; modern design; bolts and screws con
cealed; finished in two tones of green glossy
enamel.
Heating Element--No. 7 gauge boiler
plate, riveted and welded. Radiator made of
No. 12 gauge boiler plate.^ Controls which regulate temperature and
humidity are furnished.
Series No. 200 interior view, showing attractive cabinet; integral oil burner; inner casing; heating
element; blower; motor and filters.
Blower and Motor--Blower is of double
inlet type with forward curved, closely spaced blades. Moves large volume of air at
low speeds. Equipped with self-aligning bearings.
Motor is of Capacitor type and is equipped with safety device to prevent damage from
overloading. Blower and motor have extra capacity for summer cooling.
Humidifier--Either spray or drip type humidifier can be furnished. Spray humidi
fier is regulated by a Humidistat.
Filters--Sunbeam Filters provide high cleaning efficiency and long life. Are treated
.with large amount of adhesive coating without clogging the air passages.
Oil Burner--The Series Nos. 200 and 600 Units are equipped with integral co
ordinated gun type oil burners that assure high efficiency and economical fuel consump
tion. Both Series are, however, available without oil burner. Practically any gun-type
burner of the proper capacity can be accommodated.
Series No. 200--In this Unit, oil burner is placed inside cabinet as illustrated.
Series No. 600--Similar in appearance to series No. 200. Oil burner is installed at
the rear of the Series 600 and is located under the smoke pipe where it occupies no
usable space. See next page for Capacities and Dimensions.
Series No. 720-R
This series, which performs the same air conditioning
functions as the series already described, is moderately
priced, designed for small and average size homes. It is
compact and requires little space.
Exterior Cabinet--Modern design gives attractive
appearance. Die cut and formed parts connected by snug
fitting slip joints and the use of 20 gauge steel provide
rigid, air-tight construction. Finished in green crystalline
baked enamel.
Heating Element--Heavy boiler plate steel, riveted
and welded. Combustion chamber is of No. 8 gauge steel;
radiator of No. 12 gauge.
Series No. 720~R Sunbeam show ing filters. blower and motor.
Inner Casing--Galvanized iron. Air circulating between inner and outer casing keeps cabinet cool.
Oil Burner--Integral, coordinated burner is of the Rotary wall flame type. Is
completely and ingeniously assembled at the factory, assuring correct installation.
Equipment--Blower. Motor, Filters, Controls and Humidifiers same as in Series200.
See next page for Capacities and Dimensions.
893