Document nmpE522w0XwXjDr41VKOKawbw

Delco'Frigidaire Air Conditioning, Automatic Heating Systems DELCO OIL BURNER SPECIFICATIONS (based on 110 Volts--60 Cycle AC) Model Gallons OD Per Hour Maximum Capacity-Total Tax (Boiler or Furnace Output) Btu S. H.W. Motor Hp Watts Rpm DR1 1.0-1.35 105,600 440 700 1/8 S-P 135 1740 DR 1.35-2.75 216,000 900 1,440 1/8 S-P 135 1740 DI2 2.5-7.0 559,200 2,330 3,725 1/6 S-P 160 1735 D34 7.0-16.5 1,2%,000 5,400 8,600 1/3 R-l 415 1750 D44 15.0-30.0 2,880,000 12,000 19,200 3/4 R-I 760 1750 Models available for operation on other cycles, 220 Volts and DC. Lift 8'0* 8'0* 8'0* 13'(P 13'CT Pump Pounds Weight Gal Strainer Per Area Net Hour Sq In. Ship. 13 17 100 132 13 17 100 132 13 36 115 158 90 49.5 298 385 90 49.5 383 532 DELCO OIL FURNACE SPECIFICATIONS Model Capacity Total Tax Net Gal Oil Per Hour Btu Per Hour Output S HW S HW Overall Dimensions Lgth. Width Height Htg. Surf. Sq ft Cu ft Firebox Volume Height Water Line Steam Water Heater Circu lator Model Flow Vjve DM3 400 640 285 455 1.0 DH3 625 1000 485 765 1.65 DH4 1050 1675 800 1290 2.5 96,000 38'/,' 26'/,' 51 Vi* 29 2.9 150,000. 33'/,' 54Va' 55.25 4.3 252,000 36*/ 33'/,' 54'/,' 80.0 6.5 443/4* 2A* 46'// X* 46'// X* 15* 15* 22* 120* 120* 125* meDU 1400 2200 1080 1700 3.5 336,000 62s/a- 33'// 55'// 104.75 8.7 46'// X 22 125 DL6 1725 2750 1335 2140 4.5 414,000 33'/,' 55'/.' 129.5 10.75 46'/,' 2D 22 125 *Not Standard Equipment. DELCO GAS FURNACE SPECIFICATIONS Model Capacity A.C.A. Btu Total Tax Net Input Output Per Hour S HW S HW Btu 80% Eff. Overall Dimensions Htg. Lgth. width Height Surf. Sq ft Cu ft Firebox Volume Height Water Line Steam Water Heater Circu lator Model Flow Valve GH3 625 1000 485 765 187.000 150.000 4234' 33'/,' 54'// 55.25 4.3 46/,' X* 15* 120* GH4 1050 1675 800 1290 315.000 252.000 54V/ 33'/,' 54'/a' 80.00 6.5 46/,' X* 22* 125* Not Standard Equipment. DELCO OIL FIRED CONDITIONAIR SPECIFICATIONS Hourly Btu Ratings Blower Burner Max. Btu Output at Plenum Net Btu Output at Registers Max. Cfm Delivery Model Unit Fan No. Rpm d 2 Size Motor Model Hp Rpm Watts o.S Net Wt. Hp Rpm Watts 3 DA-0 100,000 85,000 1 400- 1600 660 2 * N 1/4 S-P 1725 210 DRO 1/8 S-P 1740 \ 135 8' 801. DA-1 135,000 115,000 1 400- 1600 2 * 1/4 S-P 1725 210 DRF 1/8 S-P 1740 135 8' 960 660 w\ DA-2 200,000 170,000 2 400- 2400 4 K 1/4 S-P 1725 250 DF 1/8 S-P 1740 150 8' 1435 660 DA-3 325.000 280,000 2 335- 4000 9 3/4 TC 1710 780 DF-2 1/6 S-P 1740 150 !(/ 2000 590 DELCO GAS CONDITIONAIR SPECIFICATIONS Htg. Surface Sq ft Com. Chamber Vol. Cu ft Input Mode) Btu Per Hour Output Btu Per Hour Registers Btu Per Hour Max. Cfm Cabinet Dimensions Width Lgth Hght Duct Openings Return Warm Air Ceding Height Min. meGAO 133,000 100,000 85,000 1600 70 5.5 30* 54'/,' 46y,' 21' x 25V/ * 27'/,' 6'0* GA1 181,000 135,000 115,000 1600 82 6.4 31'/,' 48' 50* 14' x 28' 18' x 28' 6'0* GA2 267,000 200,000 170,000 2400 112 10,0 33' 64V,' 50* 14'x46' 18' x 46' 6'0' GA3 400,000 300,000 255,000 4000 159 23.4 70* 86' 55* 24'x 62* 26' x 62* 6'6' 892 Air Conditioning, Automatic Heating Systems The Fox Furnace Company Elyria, Ohio Division of American Radiator and Standard Sanitary Corporation Sales Offices: Cleveland, Ouro New York, N. Y. Boston, Mass. San Francisco, Calip. SUNBEAM AIR CONDmONINO Jobbers in principal cities. Engineering layouts provided by factory Sunbeam Oil Fired Air Conditioning Units Series Nos. 200 and 600 Like gas and coal fired Sunbeam Units shown herein, this series is designed to air con dition residences and small stores, churches and other buildings. Each Air Conditioner heats, filters, humidifies and circulates the air in winter and provides circulation of filtered air in summer. Mechanical cooling can be added. Exterior Cabinet--No. 20 gauge furniture steel; modern design; bolts and screws con cealed; finished in two tones of green glossy enamel. Heating Element--No. 7 gauge boiler plate, riveted and welded. Radiator made of No. 12 gauge boiler plate.^ Controls which regulate temperature and humidity are furnished. Series No. 200 interior view, showing attractive cabinet; integral oil burner; inner casing; heating element; blower; motor and filters. Blower and Motor--Blower is of double inlet type with forward curved, closely spaced blades. Moves large volume of air at low speeds. Equipped with self-aligning bearings. Motor is of Capacitor type and is equipped with safety device to prevent damage from overloading. Blower and motor have extra capacity for summer cooling. Humidifier--Either spray or drip type humidifier can be furnished. Spray humidi fier is regulated by a Humidistat. Filters--Sunbeam Filters provide high cleaning efficiency and long life. Are treated .with large amount of adhesive coating without clogging the air passages. Oil Burner--The Series Nos. 200 and 600 Units are equipped with integral co ordinated gun type oil burners that assure high efficiency and economical fuel consump tion. Both Series are, however, available without oil burner. Practically any gun-type burner of the proper capacity can be accommodated. Series No. 200--In this Unit, oil burner is placed inside cabinet as illustrated. Series No. 600--Similar in appearance to series No. 200. Oil burner is installed at the rear of the Series 600 and is located under the smoke pipe where it occupies no usable space. See next page for Capacities and Dimensions. Series No. 720-R This series, which performs the same air conditioning functions as the series already described, is moderately priced, designed for small and average size homes. It is compact and requires little space. Exterior Cabinet--Modern design gives attractive appearance. Die cut and formed parts connected by snug fitting slip joints and the use of 20 gauge steel provide rigid, air-tight construction. Finished in green crystalline baked enamel. Heating Element--Heavy boiler plate steel, riveted and welded. Combustion chamber is of No. 8 gauge steel; radiator of No. 12 gauge. Series No. 720~R Sunbeam show ing filters. blower and motor. Inner Casing--Galvanized iron. Air circulating between inner and outer casing keeps cabinet cool. Oil Burner--Integral, coordinated burner is of the Rotary wall flame type. Is completely and ingeniously assembled at the factory, assuring correct installation. Equipment--Blower. Motor, Filters, Controls and Humidifiers same as in Series200. See next page for Capacities and Dimensions. 893