..... ' ' . . . Typical Operating Difficulties (Off-Gas) Symptom Problem Cause Possible Solutions Off-Gas Condenser Off-Gas Storage ink Hi Back Pressure on HC1 Line to Condenser HC1 temperature below 50C coming out of conden ser. Pluggage (no gas passing through.) Water temp. too cold -- HC1 temp- Water too hot erature above 50C. coming out of con denser. Water too cold r Heat water to 90C. and circulate (sewer HC1 so chlorinators can run) Control valve on water line open. 1. Raise set point on s temperature controller to desired temp. 2. Open valve on steam line 1 or 2 turns to ; heat the water. i 1. System not 1. Open water control full of water valve by lowering Circulating pump is off. set point on con troller. 2. Turn the pump on. TIC Reading Material in above 50C tank is too hot 1. Steam is on plate coil on tank. 1. Lower controller set point to close the steam valve. 2. Condenser 2. Lower set point on water too controller for i hot. condenser cooling water. Chlorine Feed High back 1. Dept. 218 1. Call operator at to chlorinators pressure valve is Dept. 218, have him are steadily on tank. closed. check his valves. lowered, ture disc obrlorwups^" on stg. tank. 2. Brink demis 2. Contact supervision. ters blinded (Sewer HC1 so chlor inators can run). Same as above High pressure - Brink Contact supervision. difference on demister Brink (above blinding i 5"). i Sudden in Too much Overcharged Check sight glasses on crease in flow coming chlorinator. all chlorinator off tank level. over in HC1 gas lines. (Check line. Sp.Gr. on all chlori- nators to guard against short charge). PCB-ARCH-EXT0374444