Healing Systems Boiiw compounds
The Vinco Company, Inc.
305 East 45th Street
-New York 17, N. Y.
Only a clean boiler can be an efficient boiler. A clean boiler means saving fuel, as well as safeguarding boiler metal. Both are now a patriotic duty.
A positively harmless insoluble powder cleaner for new, remodeled and old heating systems. A unique, scientifically processed compound on a special formula not to be confused with other powder boiler cleaners.
ttBlmESTO, Mngsysw
iy mi*
Boiler Cleanser S and 6 lb Cans
.What Vinco Boiler Cleanser Does
Vinco removes oil, grease, scale, rust and dirt from the internal surfaces and-from the boiler water without the labor, expense, and uncertain results of blowing boilers over the top or of wasting returns.
By this thorough cleaning. Vinco prevents or cures foaming, priming, surging, and slow steaming.
How Vinco Boiler Cleanser Works Each minute grain of Vinco powder adsorbs several times its own weight of oil, rust and dirt. These larger grains of adsorbed impuri ties then settle and are drained through the bottom according to directions on each can.
Vinco Guarantees
1. Vinco contains no potash, lye, soda of any kind, oil, acid, dr other harmful ingredients.
2. Purchase price is refunded if results are not as claimed when Vinco has been used according to directions.
VINCO RUST PREVENTER
When used after Vinco Boiler Cleanser has removed oil, grease, rust, scale and dirt, it will add and keep the rust inhibiting factors
at the optimal constant for a year or more. (Test kit below has complete instructions and chart.)
\
Rust Preventer 1 qt cans only
Vinco Tat Kit No. 10 - (Patent applied for)
VINCO TEST KIT No. 10
for Testing Heating Boiler Waters
The kit enables the layman to make simple, rapid tests to diagnose and prescribe correct treatment of boiler waters right on the job.
A new time saving method that permits valid conclusions heretofore requiring complicated and often lengthy laboratory analysis and technique.
Each kit has sufficient material for complete tests on 100 jobs.
Refills cost about 2 cents per test.
HELP WIN THE WAR BY SAVING FUEL AND BOILER METAL.
1066
h
The Vinco Company, Inc.
Heating Systems Qouer compounds
SPECIFICATIONS FOR COMPLETE VINCO TREATMENT OF NEW OR REMODELED STEAM, VAPOR, OR HOT WATER SYSTEMS
Do not use as a cleaning agent soda or any alkali, vinegar or any acid. Use
Vinco.
1. AFTER THE SYSTEM IS TEST
ED AND TIGHT, USE THE PROPER
QUANTITY OF VINCO LISTED.
After this first clean-out of any new or remodeled, healing system, Vinco Boiler Cleaner need be used only if more piping, radiation, or another boiler is added to the original installation, or if the system is fouled by unwise cleaning or leak-sealing experiments.
2. After using Vinco Boiler Cleaner, Vinco Field Test Kit should be used to determine and apply the proper quantity of Vinco Rust Preventer. Vinco Rust Preventer should be applied annually or whenever the boiler water is drained for necessary repairs to the system.
CONSULT THIS TABLE FOR NEW AND REMODELED HEATING SYSTEMS AND
When a Vinco Field Test Kit No. 10 is not available if cleaning old heating systems.
QUANTITIES OF VINCO (IN POUNDS) RE QUIRED FOR HEATING SYSTEMS *
(Note that quantities are based on actual installed radiation, not on boiler capacity.)
For Steam or
< Vapor Systems, toprevent orcure pruning or foam
Sq Ft of Radiation ing. AUo for Hot Water Heating
Systems Main tained at approx. 200 F or above.
Annually, to re move rust scale, dirt and for Hot Water Systems below 200 F.
SPECIFICATION FOR OLD
HEATING SYSTEMS THAT DO NOT
PERFORM PROPERLY
Diagnose and treat according to Vinco Field Test Kit. If a test kit is not avail able, consult table of quantities on this page and follow directions on Vinco cans.
SPECIFICATION FOR HOT WATER SYSTEMS
Use half quantities listed for treatment of steam systems to remove impurities. Then use test kit to determine proper quantity of Vinco Rust Preventer.
VINCO SOOT-OFF
-Above 10100 sq ft use au additional pound Vinco for each additional 300 sq ft of actual installed radiation.
Safely and thoroughly removes the insulating blanket of soot on fire pot, flues and chimney. It also insures against external corrosion (caused by dampness and soot forming sulphuric acid during summer
layoff.) No dangerous chemicals.
Soot-Off--1 lb eons 60 and 100 lb drums
REMOVE SOOT WITH VINCO SOOT-OFF SEVERAL TIMES A YEAR
VINCO SUPERFINE LIQUID BOILER SEAL
A different liquid seal. Unique in that it does not induce priming and foaming. It has no unpleasant smell. Makes speedy and permanent repairs of boiler and heating system leaks. Fine to tighten up new jobs. Directions simple.
Quantities
Steam and Vapor Systems--Use X quart Vinco Liquid Boiler Seal to each 6 sq ft grate area.
Hot Water Systems--Use 2 quarts Vinco Liquid Boiler Seal to each 6 sq ft grate area.
1067
Liquid Boiler Seal 1 qt. cons only