This Is the June 1, 1971 status of the pollution control program.
1. PCB Level In Sewers
Aroclor sower loss control data arc attached. Corjr.ents arc relative to the period k/lB/71 through 5/27/71.
A. Aroclor Department - A major lose of about 500 gallons ooeurred during the reworking of wet materiel that had been returned from a customer. Material boiled out of tank when heating. Rework procedures are being reviewed and enlargement of the department sump are actions being taken to prevent another incident. Exclusive of the major loss, the average dolly loss from the department
. was Iff/day with a range of 0.03 to l.C #/day.
B. Total Plant - Plant exit losses averaged 21/Vday v:ith a range of 11 to 61 f/day. The slug flov; loss from the Aroclor department did r.ot appear of the sane magnitude at the plant exit sewer streams. Also the treatnent plant influent stream Is about 3-^ times greater than the plant exit. Samples from other Sauget Village Industries reveal Insignificant amounts of Aroclor.
C. Treatment Plant Effluent - Average daily loss of 27 J/day with range of 8# to 75 #/day
11 Project Status
Two Aroclor units In the plant remain to be changed to ncn-rCB type fluid. Dept, 239 unit scheduled for mechanical tle-ln week of 6/15 to permit fluid change. Dept. 2t5 unit to change fluid week of 6/1.
The following are miscellaneous approved projects required to contain losses In the event they occur.
M0NS 098343
)
)
Mr. J. R. Savage - G.O. Status - PCB Pollution Control Program
Page 2
June 3, 1971 WOK
Estimate No.
2095
"Aroclor Scrap Rework" EDC 7/1/71 To permit proper rework of returned material to Dept. 21)6.
21122
"Paving and Curbing" EDC 8/1/71
To contain losses In tank car and storage area In Dept. 2*16.
2U 82
"Contaminant Collection at 'Rip Track" EDC 9/1/71 To permit recovery of T/C washings and drainings.
2675
"Air Pollution Control" EDC 10/1/71
Nitrogen blanket on mix tanks to eliminate atmospheric pollution at Dept. 2k6.
2811
"Pave under Thermlnol Unit" EDC 8/1/71 Contain material In Dept. 2<)6.
311. Program Status
Very little PCB being found in off-gas system by sampling or trapping. Confirms calculations. No additional equipment required In off-gas system, but present traps should remain an integral part of the system.