Document nm272k4nDMo2VDwvnGy92Mzez

BCCs P, D, July 6, 1970 Hr. S. K. Cavanaugh Kspey Manufacturing Coopany P. 0. Box t22 Saratoga Springs, Haw York 12666 Daar Nr. Cavanaughi Last month whan Randy Oraham and 1 vlaltad your plant to discuss tha fCB problem, wa did not Intend to oausa undue alarm or create any panic concerning tha uee and handling of polychlorinated biphenyls. Wa ware primarily Interested In sharing our ourrent knowledge of the situation with you and offered to help tdieravar wa could. All studies that we are aware of lndleate that PCB's, which are present In Monsanto's Aroolors, are not acuta poisons to humans and other wanssala, but do offact aoma apaelaa of birds and marina life. However, slnoa they are chlorinated hydrocarbons, personnel working with these materials should be protected from prolonged breathing of the fumes and from akin oontaet with tha liquid. Ventilation should be provided to keep the concentration in the working area balow 0.5 - l.Q milligram per cubic meter or air. To prevent the escape of PCB's to tbs environment alia for a level or oontrol and housekeeping many f ua have never been asked to aohleve In the past. Every effort must be made to prevent leakage and spillage. Maintenance must be kept at a vary high standard. Per those areas whera laakaga and spills will occasionally ooour, oatch pans must be provided. Theee pane oust drain to a collecting basin or be emptied by responsible employees on a scheduled baala. MOMS 088358 -2 Nixing of Aroolora with witi water atreams should be avoided slnoe separation of PCS'a from water can be oostly. If sizing cannot be avoided, a catch basin and settling pond should be provided to separate the heavy Aroolor fro* the water. Unusable contaminated Aroolor should be disposed by incineration which assures complete destruction to OOo, BgO, and MCI. Any incineration below 800C will result in vaporisation which will oontaainate the atmosphere or in partial oxidation whlah may yield materials Which are highly toxic. To help our customers with their liquid disposal problems, we have offered to accept for future in cineration scrap liquid Aroolors shipped to Monsanto Company, W. 0. Kruamrioh Plant, Saugst, Illinois, Attention Supervisor, Department 246. The charge for this disposal la 3^ per pound of material. This charge la tentative pending a complete evaluation of incineration ooate and doea not include freight or container oosts. Contamination of the atmosphere must also be elimi nated. All handling systems must bs closed wherever possible. Puaca exhausted from a tank, veaael, or working area must ba trapped and eolleeted using oondsnsers and entrainment separators. Solids contaminated with PCB's pose a greater challenge. Until a proper incinerator la designed we are euggeetlng that disposal be made in an authorised, properly operated land fill away from any water systems. These solids lneluds treatment clays, absorbing materiala used to contain spills, rags, windings and container*. In summery, oontrol of PCB's can bo achieved with equipment engineered to prevent losses and main tained properly coupled with good manufacturing prsstloss which result in a high standard of house keeping. Prom the Interest and concern whlah you have expressed 1 am oertaln that you will do all you can to reduce the esespe of PCB's from your operation. When all of us succeed in this objeotlre, 1 am oertaln that no regulatory agency will be compelled to take precipitous action regarding the use of PCB's in vital applications. Sincerely, Original Signed by W. B. Papageorge set 0.R.Oraham W. B. PAPA0B0R0K, Manager Environmental Control 6SCBB0 SNON