Document nkpRy9aXeokJ0vOnLGNB4Jgrm

E. S. Tucker - R&D Laboratories - South Second Street April 16, 1970 c< PCB CONTAMINATED MILK, STATE OP OHIO, DEPT. OF AGRICULTURE, FOODS, DAIRIES, AND DRUGS LABORATORIES_____________________ C. Weaver letter (copy attached) W. B. Papageorge General Offices R. E. Kelly - GO E. P. Wheeler - GO W. R. Richard - GO M. W. Farrar - Res. 1 R. E. Keller - Res. 1 R. H. Munch - Res. 2 GC/Mass and EC/GC analysis of the raw milk petroleum ether extract and the silo scrapings confirmed that they contain significant levels of PCB's. Unaltered Aroclor 1254 was found in the silo scrapings at a level of 2.87%, while tie raw milk extracts ..contained an estimated PCB level of 0.6-0.7 ppm. Although the isomer distribution of the PCB's in the raw milk extract was altered with respect to the Aroclor 1254 standard, the isomers present were those that occur in Aroclor 1254. This observation was further confirmed by GC/Mass analysis which detected trace amounts of tetrachlorobiphenyl and large amounts of penta and hexachlorobipheny1. The raw milk samples initially sent by ODA were destroyed in transit aud could not be analyzed. A second set was requested and upon receipt analyzed. Equivalent results were obtained and an estimated level of 0.7-0.8 ppm was found. Representative electron capture chromatograms of the sample extracts are included and even a visual examination leaves no doubt that the ODA results are qualitatively correct. I cannot address myself to the quantitative results since they did not provide us with the amounts they estimate to be present. However, we have established that our procedures are quantita tive. Interestingly, this is probably the first clear cut chance we have had to observe which PCB homologs are most resistant to metabolism, etc., in a mammal. For this reason, I have labeled the peaks in the Aroclor 1254 electron capture chromatogram according to the homolog(s) they represent. Another"Snterestfng sidelight is that we have observed strikingly similar isomer alterations in the electron capture chromatograms of an extract of a human fat biopsy fat sample, supplied to us by WARF Institute (Sample 49120924) and in extracts of raw milk samples supplied to us by the Maryland Coop Milk Producers. Both organizations had suspicioned PCB contamination, unfortunately, in both cases GC/Mass confirmation could not be obtained because of the limited amount of sample available (WARF) or the low level of contamination (MCMP). db Attachments - 3 E. S. Tucker M0NS 099542