Document nkgVZe0KKpV9M9pB8LVKNEkMw

Boilers Hart & Crouse Company General Office: Utica, N. Y. Branch Offices in Principal Cities Manufacturers of Royal Boilers and Furnaces ROYAL SMOKELESS BOILERS Actual Steam Capacities--1670 to 16,600 Sq. Ft Royal Smokeless Boiler The Royal Smokeless Boiler is of the water tube down draft principle. This principle,' originated by the Hart & Crouse Co. as applied to cast iron sectional boilers, has proved to be a most effective method of burning any grade of soft coal smokelessly independent of firing skill. The large amount of heating surface in Royal Boilers is retained intact as originally designed. Consequently they produce results with efficiency ______and economy. Boiler No. Actual Actual Current Capacity Capacity Rating Steam Water Steam Sq. Ft. Sq. Ft. Sq. Ft. Current Rating Water Sq. Ft. Heating Surface Sq. Ft. 338 339 340 341 342 343 344 345 346 347 409 4J0 411 412 413 414 415 416 548 549 550 551 552 553 554 555 556 557 558 54-8 54-9 54-10 54-11 54-12 54-13 54-14 54-15 54-16 54^17 54-18 1,670 I,965 2.370 2,680 2,975 3,280 3,585 3,890 4.200 4,500 4.250 4.750 5.250 5.750 6.250 6.750 7.250 7,775 7,400 8,470 9,480 10.200 II,250 12,200 13,000 13,900 14,800 15,700 16,600 7,400 8,470 9,480 10,200 11.250 12,200 13,000 13,900 14;800 .15,700 16,600 2,680 3,140 3.800 4,290 4,760 5.250 5,740 6,225 6,720 7.200 6.800 7.600 8,400 9.200 10,000 10,800 11.600 12,450 11,850 13.550 15,170 16,330 18,000 19.550 20,800 22.250 23,700 25,150 26.550 11,850 13.550 15,170 16,330 18,000 19.550 20,800 22,250 23,700 25,150 26.550 4.800 5.400 6,000 6,600 7.200 7.800 6,600 9.200 10,000 11,000 9.000 10.000 11,000 12,000 13.000 14.000 15.000 16.000 14.000 15.800 17.600 19.400 21.000 23.200 25.000 26.600 28.800 30.800 32.600 .14,000 15.600 17.600 19,400 21.000 23,200 25,000 26.800 28,800 30,800 32.600 7.900 8.900 9.900 10.900 11.900 12.900 14.200 15.200 16.500 16.150 14,850 16.500 18.150 19,800 21,450 23.100 24,750 26,400 23.100 26,070 29,040 32,010 34,650 38,280 41,250 44,220 47,520 50,820 53,790 23.100 26,070 29,040 32,010 34,650 38,260 41,250 44,220 47,520 50,820 53,790 179 200 220 240 262 283 316 337 360 378 324 359 394 427 461 496 531 565 511 573 642 710 773 841 909 978 1046 1114 1183 511 573 642 710 773 841 909 978 1046 1114 1183 Crate Length Area Sq. Ft. Sections Inches 14.23 17.00 19.65 22.50 22.50 25.10 25.10 28.00 28.00 28.00 24.00 27.50 31.66 31.66 31.66 35.50 35.50 35.50 37.50 45.00 45.00 45.00 52.50 52.50 52.50 52.50 52.50 52.50 52.50 37.50 45.00 45.00 45.00 52.50 52.50 52.50 52.50 52.50 52.50 52.50 50% 561/, 63 69 75'/. 81'/, 87% 94 100 106'/, 65% 72% 79% 86% 93% 101 108 115 83% 93% 104% 111244%'/, 145 176 1861/2 83% 93% 104% 114% 124% 135 145 155% 165% 176 1861/, Length Boiler Inches 66 72 78 84 90 96 102</2 109 115 121 93 >00 108 H4Vi 121*/? 129 136 143 120*/, .130? Milh 151? 161 ? 172 182 1921/, 202V? 213 223'A 98/, 108$ 119(4 1291/4 139? 150 160 1701/, 1801? 191 2OP/2 Flow .Tapping No. ana Size . 1-5* .1-5' 1-5' 1-6' 1-6' 1-6' 1-6' 1-6' 1-6' 1-6' 1-8' 1-8' 1-8' 1-8' 1-8' 1-8' 1-8' 1-8' 1-8' 1-8' 1-10' 1-10" 1-10" 1-10" 1-10* 1-10" 1-10" 1-10" 1-10" .3-6' 4-6' 4-6' 5-6' 5-6' 5-6' 6-6' 6-6' 6-6' 6-6' 6-6' pjLReturn Tapping No. and Size Smoke 1 2-3' 2-3' 2-3' 2-4' 2-4' 2-4' 2-4' 2-4' 2-4' 2-4' ' 2-5' 2-5' 2-5' 2-5' 2-5' 2-5' 2-5' 2-5' 2-5' 2-5' 2-5' 2-5' 2-5' 2-5' 2-5' 2-5' 2-5' 2-5' 2-5' 4-4' 8-4' 8-4' 10-4' 10-4' .10-4' 12-4' 12-4' 12-4' 12-4' 12-4' ' 18 18 18 18 18 18 18 21 21 21 21 21 21 21 21 24 24 24 24 24 24 24 24 ` 24 24 24 24 24 24 24 24 24 24 24 24 24 . 24 24 24 24 . Push Nipple Type.Series Additional Data 33' 40* 54' Height of water line.................................... Height of flow outlet (Header type)....... Height of flow outlet (Push Nipple type).. ............. Inches Width at twse................. .......................... ............. Inches 63 90 68 40 68 '.. 68*.. 99 108. ' 89 78 97 52 62Vz Height from top of foundation. Add 2" for floor height. 396 Hart & Crouse Company Boilers Royal New Method Smokeless Boiler ROYAL NEW METHOD SMOKELESS BOILERS (UP-DRAFT TYPE) Actual Steam Capacities-- 730 to 15,732 Sq. Ft. Actual Water Capacities--1200 to 25.966 Sq. Ft. Additional Data Series' Height of Water Line. . .. inches -Height of Mow UuUet.. Width of Boiler............ Width at Base.............. 34 46 56 36 32% 41 54 65 44 38 52 62 * 75 56 45 68 68* . 89 8OV2 62% Height to top of foundation. Add 2 in. for floor height. Boiler No. - Actual Capacity.. Steam Sq. Ft. - 634 734 634 934 . 1034 730 870 1010 1150 1290 741 1496 841 1738 941 1980 1041 2200 1141 2442 752 852 952 1052 1152 1252 1352 1452 1552 2544 2940 3336 3732 4128 4524 4920 5316 5712 768 868 968 1068 1168 1268 1368 1468 1568 1668 1768 1668 6017 6895 7779 8663 9547 10,431 11,315 12,199 13,083 13,967 14,848 15,732 Actual Sq. ft. 1200 1430 1660 1890 2120 2468 2866 3264 3662 4060 4195 4848 5501 6154 6607 7460 8113 8766 9419 9928 11,386 12,844 14,302 15,760 17,218 18,676 20,134 21,592 23,050 24,508 25,966 Current Current Rating Rating Steam Water Sq. Ft. Sq. Ft. Crate Area Sq. Ft. 1500 1800 2100 2400 2700 2450 2950 3450 3950 4450 4.43 5.50 6.57 7.64 8.71 2950 3400 3850 4300 4750 4850 5600 6350 7100 7850 7.98 9.54 11.10 12.66 14.22 _ 5100 5900 6700 7500 8300 9100 9900 10,700 11,500 8400 9725 11,050 12,375 13,700 15,025 16,350 17,675 19,000 11.50 13.75 16.00 18.25 18.25 20.50 20.50 22.75 25.00 12,200 14,000 15,800 17,600 19,400 21,200 23,000 24,800 26,600 28,400 30,200 32,000 20,125 23,100 26,075 29,050 32,025 35,000 37,975 40,950 43,925 46,900 49,875 52,850 18.75 22.50 26.25 30.00 30.0033.75 33.75 37.50 37.50 41.25 41.25 45.00 Lenph Lenph Steam. Sections Boiler Inches Inches Size 39 49 2-4' 46 56 2-4' 53 63 2-4' 60 70 2-4' 67 77 2-4' 52 63 2-5' 60 71 * 2-5' 68 79 2-5' 76 87 . 2-5' 84 95 2-5' p9 73 u 82 77 91 86 100 95 109 104 118 113 127 122 136 131 145 2-6' 2-6' 2-6' 2-6' 2-6' 2-6' 3r6' 3-6' 3-6' 73 it 114? 124? 135 145 lift 176 186% 68 98/2 1081/, 119? 129? 139? 150 160 170% 191 201% 3-6' 4-6' 4-6' 4-6' 5-6' 5-6' 5-6' 6-6' 6-6' 6-6' 6-6' 6-6' Steam Size 4-3' 4-3' 4-3' 4-3' 4-3' 4-4' 4-4' 4-4' 4-4' 4-4' 4-4' 4-4' 4-4' 4-4' 4-4' 4-4' 6-4' 6-4' 6-4' 6-4' 8-4' 8-4' 8-4' 10r4' 10--4" KM' 12-4' 12-4' 12-4' 12-4' J2--4" .Water Size 2-4' 2-4' 2-4' 2-4' 2-4' 2-5' 2-5' 2-5* 2-5* 2-5' 2-6' 2-6' 2-6' 2-6' 2-6' 2-6' 3-6' 3-6' 3-6' 3-6' 4-6' 4-6' 4-6' 5-6' 5-6' 5-6' 6-6' 6-6' 6-6* 6-6' 6-6' Water Size 4-3' 4-3' 4-3' 4-3' 4-3' 4-4' 4-4' 4-4' 4-4' 4-4' 4-4' 4-4' 4-4' 4-4' 4-4' 4-4' 6-4' 6-4' 6-4' 6-4' 8-4' 8-4' 8-4' 10-4' 10-4' 10-4' 12-4' 12-4' 12-4' 12-4' 12-4' All of the above boilers are available in Hard Coal Type. Royal Round Steam Boiler Steam No. 1035 1045 1055 1065 1075 1037 1047 1057 1067. 1077 1039 1049 10591069 1079 ROYAL ROUND BOILERS Actual Capacity Sq.Ft. Current Rating Sq. Ft. Water No. Actual Capacity Sq. Ft. 178 425 1134 284 244 625 1144 390 325 825 1154 520 415 1025 1164 664 525 1250 1174 840 200 475 1136 320 280 700 1146 450 37$ 925 1156 600 48J 1150 1166 , 768 - 625 1400 1176 1000 218 525 1138 339 300 775 1148 480 425 1025 1158 680 575 1275 1168 920 700 1600 1178 1120 397 Current Rating Sq. Ft. 700 1030 1360 1700 2060 780 1150 1525 1900 2300 870 1275 1700 2100 2640 Royal Round Water Boiler