1-J Breathing Air
BEAUMDNT WCRK3 Field Motes
1981
PLAINTIFF'S
EXHIBIT DUP-1997
a. The plant purchases corepressed air for its breathing air systems. Although each cylinder is checked for 0* and CO content, there is no periodic check of the other Grade D breathing air parameters. It is recannended that the purchased breathing air 'oe checked periodically *or Grade specifications.
b. The breathing air supplier was visited several years ago to inspect his operation but no followup contacts have been.made to insure that operations continue as intially inspected, it is recannended that annual
contacts be made to assure continued acceptable operations (See Engi neering Standard 32E).
2- J Material Safety Data Sheets
The compilation of N&terial Safety Data Sheets should include maintenance
chemicals and industrial cleaning agents. Household cleaning agents, consumer (not industrial) paints, inks, greases, etc., need not be included in the
compilation. In laboratories, Material Safety Data Sheets or other equiva lent safety monographs should be available for the followint chemicals used:
materials used in pilot plants or process development operations.
materials of moderate or greater health hazard purchased in bulk quanti ties by the storeroom.
peroxidizable compounds.
compounds known to cause strong skin reactions or irreversible eye injury and,
other highly hazardous materials used on an average of more than once per
month which have an exposure limit <10 ppm, LCs0?pm/4 hr. or LDsa 50
mg/kg (oral rat).
--
3- S Radiation Recordkeeoing
The records for the dosimeter monitoring do not contain the cumulative exposure with the exception of the exposure data for the nurses. It is recannended that the year-to--date exposure as well as the cumulative lifetime exposure be recorded. It should also be considered to issue assigned personal dosi meters for plant personnel which repeatedly has potential exposure, like the employees which do the radiation surveys.
i-S naUhretinn-of Noise level Meters
Several noise level meters and calibration sources are in 'use. Sane comparison is made between sources calibrated by a vender and others. But there is r.c schedule to have at lease cr.e source calibrated once a year and to have all
other level meters as well as calibration sources compared with it. It is
recannended that a formal schedule be introduced.
DUP 0502202
DU 001865
gcrrict___________________________rleld Met as
.Vox .-.cm-X
5-5 'false Limit
The noise boundaries are pres ericly marked at SO dEA. Since employees work 12-hour shifts, it is agreed that plans to mark hearing protection zones at 87 dSA be implemented scon.
NDJ/SS/fb