Document nkV4aExXNn8rbnq21J1v3YQ9G

BCCt P. 0. BENIQNTJ3 D. A.. 0LS0H JMly 7, 1970 Mr* Gene Lewis ?. R* Mallory Company Waynesboro, Tennessee Dear Genet X apologize for the delay, but arter further travel and a long holiday weekend X an finally sending you my comments regarding the control and disposal of Aroclors* X appreciated the tine you and your oolleagues wars able to spend with Kandy Graham and me and X was pleased X had the opportunity to tour your plant, since this gave me a better understanding of your overall problem* Gene, of all the plants Z personally toured, yours had the biggest challenge to reach the objective# we are atrlvlng for. I tell you this not to eabarass you but, hopefully, to give you some feel for the magnitude of the problem* First, let us consider the welfare of your employees. Aroclors, being chlorinated hydrocarbons, should not be permitted to exceed 0.5 to 1.0 milligram per cubic foot of air In the work area. In your operation. In splta of an operating ventilation system, the presence of Aroolor was noticeable by the blue haxe present and Insensitive as X have become, the amount was high enough to cause eye Irritation which persisted for several hcurs, after the exposure. Another area of employee exposure is direct skin oontaot with the liquid Aroolor. Contact should be eliminated by operating changes or by providing protective gloves and clothing. . COMPANY CONFIDENTIAL TRAN 061672 STLCOPCB4024915 -2' To prevent the esoape of TCB'n to the environment call* for * level of control and housekeeping many of us hair* never been asked to aohlove in the past. Every effort oust b mad* to prevent leakage and spillage. Mainte nance must be kept at a very high standard. Tor those areas there leakage and spills till occasionally occur, catch pans sruat be provided. These pans oust drain to - a collecting baoln or be emptied by reaponalble employees on a scheduled basis. Mixing of Aroclor* with waste water etreams should be avoided alnee separation of FCB's fro water oan be costly. If nixing cannot be avoided, a catoh basin end settling pond should be provided to separate the heavy Aroolor from the water. Unusable oontaolnated Aroclor should be disposed by Incineration thloh assures oooplete destruction to COc, **** ^ Inolneratlon below 0OOfl will result In vaporisation Which will contaminate the atmosphere or In partial oxidation Wilch may yield materials which are highly toxic* To help our customers with their liquid disposal pro blems, we have offered to accept for future Incineration scrap liquid Aroclors shipped to Koosanto company. V. 0. Kruoarlch Plant, Saugtt, Illinois. Attentlooi Supervisor, Z)*partaenfc 246. The charge for this dis posal Is 3^ par pound of material. This charge Is tentative pending a complete evaluation of Incineration costs and does not include freight or container coats. Contamination of the ataospbere must also be eliminated. All handling system* eust os closed wherever possible. Fumes exhausted fro* a tank, vessel, or working area must be trapped and collected using condensers and entralnoent separators. Solids contaminated with fCB's pose a greater challenge. Until a proper incinerator Is designed, we are suggesting that disposal be wade In an authorized, properly operated land fill away froa any water systems. These solids include treatment day*, absorbing materials used to ocntaln spills, rags, windings and containers. In summary, control of ?CBr* can be achieved with equipment engineered to prevent losses and maintained properly coupled with good manufacturing practices which result in a high standard of housekeeping. ' COMPANY CONFIDENTIAL TRAN 06167 3 STLCOPCB4024916