UST Inspection Report South Dakota Department of Transportation in McIntosh Date of Report: Inspection Date & Time: Weather: Facility Owner: Facility Owner Address: October 27, 2023 September 27, 2023, at 1:00 p.m. MDT Sunny, ~68 degrees Fahrenheit South Dakota DOT 700 E. Broadway Avenue Pierre, SD 57501 Facility Address: 106 Highway 12 North McIntosh, SD 57641 Facility Phone: Facility Representatives: EPA Facility ID Number: Reason for Inspection: Inspector(s): 605-273-4430 James Brooks, Arlen Halverson 4040016 Routine Compliance Inspection Andy Woodward, EPA Marta Grabowski, EPA UST System Description South Dakota Department of Transportation in McIntosh (Facility) is a state-owned fueling station located within the boundary of the Standing Rock Reservation, South Dakota. The fuel at this Facility is only for the private use of state-owned highway maintenance and emergency management vehicles. The Environmental Protection Agency's records indicate that the Facility has two fiberglass reinforced plastic (FRP) underground storage tanks (UST), which were installed on January 7, 2021. The first tank (Tank 1) is 2,000 gallons and contains regular unleaded. The second tank (Tank 2) is 3,000 gallons and contains diesel. The Facility piping is a pressurized system with double-walled, flexible plastic (FP) construction. Inspection Narrative On September 27, 2023, the EPA UST program personnel conducted an inspection at the Facility in McIntosh, South Dakota. The EPA last inspected the Facility on November 2, 2020, and it was selected for routine reinspection. On September 19, 2023, Andy Woodward spoke to the Facility manager to schedule the inspection and asked for a list of UST documents to be available for the inspectors to review (see Attachment A). 4040016 - SD DOT McIntosh Page 1 of 3 9/27/2023 UST Inspection The EPA inspectors arrived at the Facility at approximately 1:00 p.m. Mountain Daylight Time (MDT). Andy Woodward introduced himself and presented his inspector credentials. He filled out a Notice of Inspection (NOI) (see Attachment B) and requested a signature. Andy explained that the NOI serves as documentation of consent for the EPA to conduct an inspection. He stated that he would provide the NOI to them at the end of the inspection. The EPA inspectors began with a physical inspection of the UST system, followed by a review of the Facility UST records. EPA inspectors took photographs of the UST system components during the inspection (see Attachment C). A Facility representative assisted with the physical inspection. Tank Leak Detection Tank leak detection consists of interstitial monitoring sensors and a Veeder Root TLS-450 automatic tank gauge (ATG) system. The Facility representative provided the last twelve months of printouts from the system console for both tanks. Normal monthly tank sensor readings and passing tank leak detection tests from October 2022 through September 2023 were physically observed for both tanks. The tanks' ATG was tested on October 19, 2022, by TNA Electric LLC. Piping Leak Detection The Facility's piping is equipped with electrical automatic line leak detectors (ELLD) and requires interstitial monitoring for leak detection. Facility documents indicate monthly sump sensor readings were operating in normal status with no activated alarms. Line leak detection test for the ELLD's, were performed by TNA Electric LLC on September 29, 2022. All sump sensors were tested on November 2, 2022 (see Attachment D). Cathodic Protection This Facility does not require cathodic protection because the tanks are fiberglass reinforced plastic, and the piping is flexible plastic. Periodic Testing/Inspection of Spill and Overfill Prevention Equipment New double-wall spill buckets and overfill alarms were installed and put into operation on January 7, 2021. Periodic Operation & Maintenance (O&M) Walkthrough Inspections Documentation of monthly walkthrough inspections from October 2022 through September 2023 were completed and available for review. Current annual walkthrough inspections were unavailable at the time of the inspection. Operator Training The Facility provided class A/B operator training certificates for Arlen Halverson from South Dakota Department of Environmental Quality (DEQ) dated December 9, 2020. Class C operator training records were not available at the time of inspection. Financial Responsibility The Facility is covered by the South Dakota Petroleum Release Compensation Fund. 4040016 - SD DOT McIntosh Page 2 of 3 9/27/2023 UST Inspection Physical Observations EPA inspectors viewed the spill buckets, overfill alarm, tank sumps, submersible turbine pumps, automatic tank gauges, vent lines and ATG console. All appear to be functional and intact. Conclusion At the conclusion of the inspection, Ms. Grabowski notified the Facility that it was out of compliance and filled out an Onsite Deficiency Identification Form (see Attachment E), addressing the areas of noncompliance and the recommended corrective actions required to be taken. These items were identified from the inspection checklist (see Attachment F). Mr. Woodward completed the NOI form and the Facility representative signed and received a copy. The EPA Inspectors thanked them for their time and left the premises. Inspection Report Attachments A. Record of communication for scheduling the inspection B. Notice of Inspection C. Photo log D. O&M Records and Documentation E. Onsite Deficiency Identification Form F. Inspection checklist Signature Lead Inspector R WOODWARD (Affiliate) Date: 2023.10.27 15:29:17 -06'00' Digitally signed by R WOODWARD (Affiliate) Andy Woodward Date of signature 4040016 - SD DOT McIntosh Page 3 of 3 9/27/2023 UST Inspection