HEATINC VENTILATINC AIR CONDITIONING CUIDE 1944 FLUID METERS The perfection of fluid meters has contributed as much to the advance ment of district heating as any other one thing. Meters are classified into two groups: Quantity Meters and Rate of Flow Meters. Quantity Meters The one type of quantity meter used is the condensation meter, which may be of the tilting bucket or revolving drum type. The condensation meter is a pdpular type for use on small and medium sized installations, where all the condensate can be brought to a common CHAPTER 43. DISTRICT HEATINC difference. The position of the plug is transmitted by means of a lever and pencil and records the flow on a graduated strip chart. Head meters are those in which the stream of fluid creates a difference of pressure, or differential head. This head is created by an orifice, Venturi tube, flow nozzle, or Pitot tube and will depend upon the velocity and density of the fluid. The secondary element must contain a differential pressure gage, which Fig. 6. Gravity Installation for Condensation Meter Using Vented Receivers point for metering purposes. Its simplicity of design, ease in testing, accuracy at all loads, low cost, and adaptability to-low_pressure distribu tion has made it standard equipment with many heating companies. Condensation meters should not be operated under pressure; they are made for either gravity -or vacuum installations. Where bucket traps are used, a vented receiver is essential ahead of the meter. Where con tinuous flow traps are used, a vented receiver is not necessary, but is desirable. Fig. 6 illustrates a gravity condensation meter installation using ai vented receiver. Rate of Flow or Flow Meters Flow meters used for district heating work are of three types: Area Meters, Head Meters and Velocity Meters. Area meters are those, in the operation of which, a- variation in the cross-section of stream under constant head is used as an indication of the rate of flow. A tapered plug is suspended in an orifice and moves axially with the flow, which is vertically upward. The weight of the plug provides a definite pressure differential and the plug floats at such a height as will provide enough orifice area to pass the flow at the pressure 768 .. Fig. 7. Orifice Meter Steam Supply Connection will translate the pressure difference into rate of flow or total flow. This mechanism may be either mechanical or electrical. The electric flow meter has the advantage of being able to locate the instruments as some distance from the primary element. Fig. 7 is a typical example of an orifice-type meter installation. A few general points to be considered in installing a meter of this type are: (1) It is desirable to place the differential medium in a horizontal pipe in preference to a vertical one, where either location is available. (2) Reservoirs should always be on the same level and installed in accor dance with the instructions of the meter company. (3) The meter body should be placed at a lower level than that of the pressure differential' medium. Special instructions are furnished where the meter body is above. (4) Meter piping, should be kept free from leaks. (5) Sludge should not be permitted to collect in the meter bbdy. (6) The meter body and meter piping should be kept above freezing temperatures. (7) It is best not to connect a meter body to more than one service. (8) Special instructions are furnished for metering a turbulent or pulsating flow. Velocity meters are those in which the primary element is some device that/is kept in continual, rotation by the linear motion of the stream. 769