Document nkGkemjZRp9Q3JLq8VMd37NNm

CertainTeedH cr.^c cs- (4 TO: All District Sales Managers All Territory Managers All Administrative Supervisors All Inside Sales Representatives All Field Service Managers All A/C Plant Managers All A/C Customer Service Managers FR: Frank T. Duffy/bam ( RE: A/C SEWER PIPE REDESIGH After much too long a time it appears that we are rapidly approaching the acceptance by ASTM of a redesigned A/C Sewer Pipe. This technical bulletin is being issued to give you foreknowledge of what is proposed so you will not have any surprises or become victims of any misinformation. There are really only two basic changes in the standard. We have abandoned our present class system which is difficult to defend from an engineering standpoint and adopted a classification system which makes much better engineering sense. We have also abandoned our present wood block crush test method in favor of the ISO "V"-block. The ISO "V"-block gives us much better fidelity in the tests and it is the method prescribed by the InterNational Standards Organization. Crush classification merely means that for any given series as the diameter increases the crush strength increases. This is the system that clay and concrete have used for years and it is amiable to the common sense notion that the bigger the pipe the more load it has to carry. The ASTM committee has tentatively decided that the market would be best served by three series of pipe rather than clay's two series and concrete's three series in non-reinforced pipe and five series in reinforced pipe. The committee further decided that our pipe should be designed on the basis of "B" bedding (load factor = 1.9), safety factor = 1.5, and depths of bury of 8'-0", 14'-0" and 20'-0". These three series will encompass approximately 98% of the pipe we sell. We have attached three tables comparing our proposed crush values with the appropriate clay and concrete values. CTD000721 t\ L- L-- t . l-- -- I 5 1379 Bulletin No. 33 Date: 5/9/79 2- - Be advised that in no way do we ever suggest or imply that our pipe is good for 8'-0" bury, 14'-0" bury or 20'-0" bury. The depth of bury is a function of the bedding and safety factor and as always the pipe selection is the responsibility of the engineer. The ASTM committee has decided to establish a minimum crush value of 15000/ft. The flex values are exactly the same as now prescribed in ASTM C-428 based on comparable crush values. Roman Korobij will issue a more technically detailed bulletin to the sales engineers, A/C Quality Control Managers and R&D. If you have any questions, Roman Korobij or I will be happy to answer them for you. cc: L. C. Ambler, VF P&PG J. F. Baker, VF P&PG A. J. Buford, VF P&PG C. J. Demarest, VF USG A. W. Hunt, VF P&PG J. G. Kelso, VF P&PG J. E. Mead, VF P&PG J. P. McGinley, VF P&PG J. A. Moses, VF P&PG J. L. Prechek, VF P&PG L. C. Prindiville, St. Louis, it264 R. J. Smith, VFP&PG C. H. Striegel, BB P&PG N. P. Sutterer, VF P&PG J. P. Ungerman, BB P&PG CTD000722 SIZE 4" 5" 6" 8" 10" 12" 14" 15" 16" 18" 20" 21" 24" 27" 30" 33" 36" 39" 42" SIZE 4" 5" 6" 8" 10" 12" 14" 15" 16" 18" 20" 21" 24" 27" 30" 33" 36" 39" 42" 3 PIPE PROPOSED A/C SEWER CRUSH VALUES VERSUS COMPETITIVE PRODUCTS A/C V-BLOCK CRUSH SERIES I 1500 1500 1500 1500 1600 1800 1900 2000 2000 2200 2300 2400 2600 2800 3000 3200 3400 3700 3900 VCP CRUSH STANDARD STRENGTH 1200 - 1200 1400 1600 1800 - 2000 - 2200 - 2400 2600 2800 3300 3600 4000 - - NON-REINFORCED CONCRETE C-14 CRUSH CLASS I 1500 - 1500 1500 1600 1800 - 2000 - 2200 - 2400 2600 2800 3000 3150 3300 - - A/C V-BLOCK CRUSH SERIES II 2000 2000 2000 2000 2200 2400 2600 2600 2800 3000 3200 3300 3600 3900 4200 4 500 4900 5200 5500 VCP CRUSH EXTRA STRENGTH 2000 -- 2000 2200 2400 2600 - 2 700 - 3300 - 3850 4400 4700 5000 5500 6000 6600 7000 C-14 CRUSH CLASS 2 2000 2000 2000 2000 2250 _ 2600 3000 _ 3300 3600 3950 4300 4400 4500 - - REINFORCED CONCRETE C-76 0.01" CRACK CRUSH CLASS II - 1000 - 1250 - 1500 - 1750 2000 2250 2500 2750 3000 - 3500 C-76 0.01" CRACK CLASS III 1350 1688 2025 2363 2700 3038 3375 3713 4050 4725 CTD000723 -4 - SIZE 4" 5" 6" 8" 10" 12" 14" 15" 16'1 18" 20" 21" 24" 27" 30" 33" 36" 39" 42" A/C V-BLOCK CRUSH SERIES III 2000 2000 2000 2300 2500 2700 3000 3100 3200 3500 3800 3900 4300 4700 5100 5500 6000 6400 6800 VCP CRUSH EXTRA STRENGTH 2000 - 2000 2200 2400 2600 - 2900 - 3300 - 3850 4400 4700 5000 5500 6000 6600 7000 C-14 CRUSH CLASS 3 2400 - 2400 2400 2400 2600 - 2900 - 3300 - 3850 4400 4600 4750 4875 5000 - - C-76 0.01" CRUSH CLASS - - 2000 - 2500 - 3000 - 3500 4000 4500 5000 5500 6000 - 7000 CTD000724