Document nkD5gwpKZ27jeOrGbV1vdYBzw
Monsanto
TO
E. E. Stewart, W. G. Krummrich_Plant
April 3, 1975
PCB - ANALYSIS
laboratories
David Wood H . ,J . Horne
Mr. VI. B. Papageo.rge General Offices BIND
I checked with some of the plants where we sampled their effluent streams for PCB content to determine what additional laboratories were used by the respective plant as a possible cross-check on our analyses.
You were interested in getting information on labora tories offering services for PCB analyses.
I. Electrical Utilities, LaSalle, Illinois
(Did not cross-check, but in the past have sent
samples to)
Li nineties, Inc. 6132 West Fond du Lac Avenue Milwaukee, Wisconsin 53218 Phone 414/461-9500
You have this listed in ANSI C107.1 - 1974.
II. Aerovox Industries, New Bedford, Mass. (Did cross-check with two additional companies)
'
Woodson Tennent 345 Adams Avenue P.0. Box 2135 Memphis, Tennessee Phone 901/525-6333
38101
.
*New England Analytical Testing Laboratory
2 Shady Oak Lane
'
Netick, Massachusetts 01760
Phone 617/873-8469
Comparable results as follows:
.
Monsanto WGK Lab Woodson Tennent New England Analytical
' Testing Laboratory
19.7 ppb 11.1 18.7
TOWOLDMONOQ57242
Mr. W. B. Papageorge PCB - ANALYSIS LABORATORIES____
Page 2 A/3/75 WGK
III. Cornell Dubilier Electronics New Bedford, Mass.
Did cross check with the same two laboratories iisted above for Aerovox Industries.
Monsanto
New England Analytical Testing Laboratories
Woodson Tennent
<0.25 45.1
705.3 11.1
ppg
0.54 107.8 337.8
3.02
ppb
389
IV. Westinghouse Bloomington, Indiana
. Did cross-check with one of their Sharon plant laboratory.
Monsanto
4,600 ppb
Westinghouse
3,170
(Sharon Laboratory)
V. Mallory
.
Waynesboro, Tennessee
Did cross-.check with their laboratory for Physical Sciences in Burlington, Massachusetts.
Do not have data but was told three of the four samples checked closely.
Did not check any other plants.
1 would suggest that customers submit their effluent samples to the WGK laboratory for analysis (any legal ramifications?) At this time we have the equipment, the time, the expertise, and the analyses can be grouped with our plant samples such that customer cost per sample may be lower than he \ould pay at a commercial laboratory.
TOWOLDMONOQ57243
Mr. W. B. Papageorge PCB - ANALYSIS LABORATORIES :_______
Page 3 . : A / 3 / 7 5
WGK
If analysis of customer effluent streams by WGK laboratory is a viable alternate, the cost to the customer will be $40 per sample. Sample to be sent in 16 oz. glass bottles (no other size.)
Send to:
Monsanto Company
.
William G. Krummrich Plant
Sauget, Illinois 62201
Attn: Mr. H. J. Horner
Let me know if you need additional information.
/ tm
Edward E. Stewart
01<>^218
TOWOLDMONOQ57244