CHAPTER 20
1953 Guidii
X. / J
Table 3. Capacity Tables fob Warm Aib and Retdbn Aib Bbancii'es*. *
' FIRST STORY
.For
ATED
Metal Ducts
Actual Length (from Bonnet to Boot) or, (from Return Plenum to Boot) m Feet
1 to 7 FT.
Col. a
8 TO 12 FT.
13 TO 1* 18 to 24 25 to & FT. FT. FT.
35 to 44 45 to 54 FT. FT.
Col. b
Col. c
Col. d
Col. e
Col. f
Col. g
Warm
Air Combi-
NATION
No.
Return Air
Combi
nation
Section A.
40 to.69 Equivalent
. Ft for Fit tings and Register
Section B.
70 to 99 Equivalent Feet
7200 12500 16000 19100
6700 11700 15000 18000
25000 23400 32000 30000 80000 75000
5500 9900 13100 16300
5100 9200 12300 15400
19800 .18400
26200 24600 65500 61500
6100 10800 14000 17000
21600 28000 70000
4800 8600 11600 14500
17200 23200 58000
5600 9900 13000 16000
19800 26000 65000
4500 8100 10900 13700
16200 21800 54500
4800 8500 11300 14200
17000 .22600 56500
3900 7100 9700 12200
14200 19400 48500
4100 7400 9900 12500
14800 19800 49500
3400 6200 8500 10800
12400 17000 42500
3500 6400 8700 11000
41 42 43 44
12800 17400 43500
45= 46=
3000 5400 7500 9500
41 .- 42
43 44
10800 15000 37500
45= 46=
51 52 53 54
55 56 57=
51 52 53 54
55 56 57=
Section C.
100 to 129 Equivalent Feet
4600 8500 11300 14300
4300 7900 10600 13500
17000 15800 22600 21200
56200 .52600
4100 7400 10000 12700
14800 20000 50200
3800 6900 9400 11900
13800 18800 47300
3300 6100 8400 10500
12200 16800 42000
3000 5300 7400 9300
10600 14800 37000
2700 4700 6500 8300
9400 13000 32400
41 42 43 44
45= 46=
51 52 53 54
55 56 57=
Section D.
130 to 164 Equivalent Feet
4100 7300 9800 12300
14600 19600 49200
3800 6900 9100 11700
13800 18200 45800
3600 6400 8600 11000
12800 17200 41900
3400 6000 8100 10300
12000 16200 40300
2900 5300 7200 9100
10600 14400 36000
2600 4700 6400 8100
9600 12800 31800
2300 4200 5600 7100
8400 11200 28100
41 42 43 44
45= 46=
51 52 53 54
55 56 57=
Section E.
165 to 200 Equivalent Feet
3800 6500 8800 11000
13000 17600 4410)
3500 6100 8200 10600
12200 16400 41500
3300 5700 7700 9900
11400 15400 38800
3100 5400 7200 9300
10800 14400 36000
2700 4800 6400 8300
9600 12800 32000
2400 4300 5700 7300
8600 11400 28200
2100 3800 5000 6400
7600 10000 24700
41 42 43 44
45= 46=
51 52 53 54
55 56 57=
Fob
INSULATED
1 Col. a
1 to 9 - FT.
Col. b
10 TO 17 FT.
Col. c
18 TO 24 FT.
Col. d
25 to 34 FT.
Col. e 54 FT.
COMFob Ducts that are PLETELY INSULATED
with } In. Thick Insul-
ation from Bonnet to Boot,
use these Column Headings.
b~ .
1,10,01 ^ TM wwng oo;n tne warm air and the return air branches,
e TMtwmd reaistanas and temperature drops in ducts have both been accounted for in these tobies!
two or fLT ^isterabUildin* wnatruction' r Paty requirements, necessitate the use of
Forced Warm Air Systems
467:
Table 4. Capacity. Tables fob. Warm-Aib and. Retdbn Aib Branches** b
SECOND STORY
'Fob uninsu
lated
'Metal Ducts
Actual Length (fbom Bonnet to Boot) ob, (from Return Plenum to Boot) in Feet
.-
1 to 7 FT.
Col. a
8 to 12 FT.
Col. b
13 to 17 18 to 24 25 to 34 35 to 44 45 to 54 ft. FT. FT. FT. FT.
Col. c Col. d
Col. b
'Col . f Col. g
Warm
'` ` / 'Return/
Combi- - Combi
NATION nation
' No. ` , No.
- A
Section A.
40 to 69 Equivalent Ft for Fittings
Register
6300 10900 14000 17000
5700 10000 13000 15900
21800 20000 28000 26000 70000 ; 65000
5200 9200 12100 14900
18400 24200 60500
4800 8500 11400 13900
17000 22400 57000
4100 7300 10000 12400
14600 20000 50000
3500 6400 8800 11100
12800 17600 44000
3100 5600 7800 9900
41 51 42 -52
43 53 44 54
11200 45= ! ; 55
15600 46=
56
39000 ' J.
57=
Section B.
70 to 99 Equivalent Feet
5000 9000 11900 14800
18000 23900 59500
4600 8200 11000 13900
: 4300 7600 10300 13000
16400 15200 22000 20600 55000 51500
4000 7100 9600 12200
14200 19200 48000
3400 6200 8400 10800
12400 16800 42000
3000 5400 7500 9600
10800 15000 37500
2700 41, 4700. *42 6700 43 8500 44
9400 13400 33500
45= 46= --- ` 1
51 52 53 54
55 .. 56 57=
Section C.
100 to 129. Equivalent Feet
4200 7700 10400 13000
15400 21700 52200
3900 7200 9700 12100
. 3700 6700 9000 11300
14400 13400 19400 18000 48400 45300
3500 6200 8400 10600
12400 16800 42300
3000 5400 7400 9400
10800 14800 37000
2600 4700 6500 8300
2400 4100 - 5800 7400
9400 13000 32500
8200 11600 29000'
41 42 ' 43 44 .
45= ' 46=
--
51 52 53 54
55 56 57=
Section D.
130 to 164 Equivalent Feet
3800 6800 9100 11400
13600 18200 45500
3500 6300 8400 10500
12600 16800 42000
3200 5800 7900 9800
11600 15800 39600
3000 5500 7400 9200
11000 14800 36800
2700 4800 6300 8100
2300 4200 5700 7200
9600 8400 12600 11400 32200 ,28200
2100 3700 5000 6400
7400 10800 25100
41 42 - 43 44
45= 46= --
51 52 53 54
55 56 57=
Section E.
165 to 200 Equivalent Feet
3500 6100 8200 10300
12200 16400 41000
3200 5700 7600 9500
11400 15200 38300
2900 5300. 7100 8900
2700 5000 6700 8300
10600 10000
14200 13400 35800 33400
2500 4400 5700 7400
8800 11400 29000
2100 3900 5100 6500
7800 10200 25800
1900 41 , 3400 42 4500 43 5800 ' 44
6800 9000 22800
45' 46c .-- *
51 52 -53. 54
55 56 57
insulated Ducts
Col. a
1 to 8 FT.
Col. b
9 to 14 FT.
Col. c
15 to 20 FT.
Col. d
21 to 27 FT.
C0I>. E 28 TO 42
Col. f 43 to 54
Fob Ducts that are COM-pletely insulated
with i In. Thick Inbulati on from Bonnet to Boot Use thesb Column Hradings.
* These tables are for use in sizing both the warm air and the return air branches. ** Frictional resistance and temperature drops in ducts have both been accounted for in these tables. 8 Use these items only when the building construction, or capacity requirements, necessitate the use of two adjoining stacks or floor registers.