Document nk6ov4ZpZ7ERaq83ON4YYM0ER
Detoxication
of Hazardous Waste
Edited by Jurgen H. Exner
ANN ARBOR SCIENCE
np
THE BUTTERWORTH CROUP
HONS 221556
Copyright 1982 by Ann Arbor Science Publishers 230 Collingwood, P.O, Box 1425, Ann Arbor, Michigan 48106 Library of Congress Catalog Card Number 82-70696 ISBN 0-250-40521-0 Manufactured in the United Stales of America All Rights Reserved Buttcrwonhs, Ltd,, Borough Green, Sevenoaks Kent TN15 8PH, England
HONS 221557
PURPOSE AND SCOPE OF THIS BOOK (PREFACE)
A great variety of treatment techniques can be applied to solve our current pollution problems. The chapters in this book demonstrate that detoxication of hazardous waste can be achieved by creative adaptation of existing, fundamental knowledge by workers with a multidisciplinary outlook. However, the actual implementation of the technical solutions often depends on the necessary interaction with nonscientific members of society and on numerous value judgments and decisions about risk levels, potential consequences and political realities.
This book, based on a symposium by the Division of Environmental Chemistry of the American Chemical Society, focuses on the detoxication of hazardous waste as an alternative and/or a complement to storage and destruction techniques. The book contains four sections:
1. incineration amt watte mamigcmeni; 2. treatment, recovery and denrucuon of polychlorinated biphenyl* (PCB); 3. a catc study of the deatmeuon of dioxint; and 4. the biological detoxication potential of genetic engineering, microbial and en
zymatic techniques.
Section 1 describes the design and operation of multipurpose indusiria! incinerators for regional waste treatment centers. The question of destruc tion of hazardous components and their removal efficiency as a function of operating conditions of the incinerator is discussed, and the ranking of hazardous compounds for incinerabiliiy is debated in several funda mental chapters. The concern about the potential emission of toxic combustion by-products such as polychlorinated dioxins and furans is addressed and illustrated by data on the emission of these compounds during incineration of PCB.
v
HONS 221558
Section 2, on PCB detoxication, illustrate* the diversity of possible approaches to treating a specific type of waste and serves as a model for detoxication of other pollutants. Land* and ocean-bated, molten salt, diesel, and cement kiln incineration have been tested. Plasma arc and other high-temperature processes have been explored. The treatment of PCB-contaminated transformer fluids illustrates the role of detoxication in recovery and reuse of valuable chemicals, PCB destruction by organometalt, ultraviolet light, alkali metal alkoxides and chemical reduction are feasible and have been tested by numerous investigators.
No compounds, other than perhaps PCB, have achieved the public recognition and fear of polychlorinated dibenzodioxins. The case study of a project that destroyed 7 kg of tetrachlorodibenzodioxin in a complex, hazardous waste illustrates how social values, political judgments and legal requirements affect attempts to detoxicate hazardous waste. In addition, the' project demonstrates clearly that the technical expertise exists to solve even the most difficult pollution problem.
Section 4 focuses on the future by examining the exciting potential of selected mutation or genetic engineering of microorganisms to detoxicate hazardous waste, and contaminated soils, lagoons or groundwaters. Also, enzymes may catalyze slow chemical reactions for treating pollutants.
Although these biological methods appear attractive, many problems still must be overcome. In the meantime, we have available a wealth of fundamental knowledge that can be adapted to pollution problems by chemists, engineers, microbiologists, physicists, geologists, toxicologists and many others. At present, implementation of technical solutions is being delayed by legal, political and societal discord and arguments. A number of solutions to diverse pollution problems are offered in this book. 1 hope that these solutions can demonstrate what can be accom plished if we have the will to actually solve the problem of hazardous waste.
Jurgen H. Exner
HONS 221559
ACKNOWLEDGMENTS
I thank Dr. R. B. Pojasek for suggesting the possibility of this book, B. Monopoti for her tireless editorial assistance and my family for accepting many lost weekends.
Jurgen H. Exner manages the research and development activities of IT Enviroscience, Knoxville, Tennessee, the consulting and engineering division of IT Corporation, a national waste management company headquartered in Wilmington, California. He received a PhD in Organic Chemistry from the University of Washington in 1968 and a BS from the University of Minnesota in 1963. During the last seven years he has assessed waste profiles and disposal options for wastes from chemical and pharmaceutical manufacturers. He has developed and implemented pro cesses for recovery, treatment or detoxication of organic residues, metals, halogenated aromatics and toxic gases. His most recent accomplishment was to develop and carry out a process for destroying the highly toxic tetrachlorodibenzodioxin in a hazardous waste. His work in hazardous waste treatment and disposal and in organometal, carbanion and cation chemistry has been published in 21 articles and talks. He has been granted seven patents from his work at Dow Chemical and IT Enviroscience.
Dr. Exner organized and was chairperson of a two-day symposium of detoxication of hazardous waste at the 182nd National Meeting of the American Chemical Society, New York, August 1981. Dr. Exner was the 1981 chairman of the East Tennessee Section of the ACS. He is a member of Phi Beta Kappa, Tau Beta Pi and Phi Lambda Upsilon.
HONS 221561 viii
CONTENTS
Introduction................
xiii
Section 1 Incineration and Waste Management
1. Hazardous Waste Detoxication at Contract Waste Management Facilities................................................................. C. Youngson and J. Ferriera
3
2. Chemical Processes in the Incineration of Hazardous Materials.................. W. Tsang and W. Shaub
41
3. Combustion Characteristics of Chlorinated Hydrocarbons ............................ S. M. Senkan
61
4. Impact of the Resource Conservation and Recovery Act on the Design of Hazardous Waste Incinerators.................. J. jV. Clark and J, J, Cudahy
93
5. Using Solidification as a Waste Detoxication Process........ 109 R. B. Pojastk
ix MOMS 221562
Section 2 Polychlorinated Biphenyls: Treatment, Recovery and Destruction
6. Summary of Polychlorinated Biphenyl Treatment Alternatives ................................................................. . J. H. Exner
119
7. Federal Polychlorinated Biphenyl Regulations.................... 121 M. Velie and G. Kumz
8. Treatment and Destruction of Polychlorinated Biphenyls
and Polychlorinated Biphenyl-Contaminated Materials.... 131
L. Weitzman
'
9. incineration of Chemical Wastes Containing Polychlorinated Biphenyls: Assessment of Tests Conducted at Rollins Environmental Services, Deer Park, Texas, and Energy Systems Company, El Dorado, Arkansas............................... 143 T. O. Turnon, M. L. Taylor, J. G. Solch, G. F. Vanness, J. H. Garrett and M. D, Porter
10. Ultimate Disposal of Polychlorinated Biphenyls.................. 185 T. G. Barton and G. P. Arsenault
11. Chemical Destruction of Polychlorinated Biphenyls in Transformer Oil.......................................................................... J. F. Brown, Jr., M. E. Lynch, J. C. Carnahan and J. Singleton
201
12. Light-Activated Reduction of Chemicals for Destruction of Polychlorinated Biphenyls in Oil and Soil............................. 215 J. F. Kitchens, W. E. Jones, III, G. L Anspach and D. C Schubert
13. Catalyzed Wet Oxidation of Hazardous Wastes ................... 227 R. A. Miller and R. D. Fox
14. Kinetics Model and Simulation of Concentration Variations of Species of Polychlorinated Biphenyls Involved in Photochemical Transformation................ V. Kalmaz, R. B. Craig and G. W. Zimmerman
233
x HONS 221563
Section 3 Destruction of Dioxins: Case Studies
15. Chlorodibcnzodioxins and Chlorodibenzofurans:
An Overview ................................................................................. T. O. Tieman
243
16. Selected Legal Aspects of a Dioxin Detoxication Project.. 261 K. A. Siormer
17. Process for Destroying Tctrachlorodibenzo-p-dioxin in a Hazardous Waste......................................................................... 269 J. H. Exner, J. D. Johnson, O. D. Ivins, M. N. Wass and R, A. Miller
18. Environmental Health and Safety Considerations for a Dioxin Detoxication Process ................................................................... 289 C. J. Sawyer
Section 4 Biological Detoxication: Genetie Engineering,
Microbial and Enzymatic Treatment
19. Opportunities for Development of New Detoxication Processes Through GeneticEngineering..................................... J. B. Johnston and S. G. Robinson
301
20. Potential Role of Genetically Engineering Microorganisms to Degrade Toxic ChlorinatedHydrocarbons ......................... G. . Pierce
315
21. Microbiological Separation for Trace-Organics Removal... 323 B. . Rittmann and H. Kobayashi
22. Peroxidase for Removal of Hazardous Aromatics from Industrial Wastewaters..................... ............... .................... B. N. Alberti and A. M. Klibonov
349
Index.......................................................................................................... 357
xi HOMS 221564
INTRODUCTION
Disposal of toxic wastes is a global problem that industrialized nations now have begun to confront in a systematic fashion. Public awareness has led to the passage of the Resource Conservation and Recovery Act (RCRA) of 1976, which regulates disposal and restricts what can be stored permanently in the ground. Such regulations are changing slowly the economics of waste disposal and, at long last, the potential benefits of source control, and recovery and recycle of waste, are being pursued earnestly. Only after rigorous investigation of recovery and recycle should landfilling or destruction alternatives be deemed appropriate. Nonethe* less, these alternatives, especially underground storage, remain econom* ically attractive. Still, increasing long-term legal liabilities and the potential for groundwater contamination are forcing a shift from storage to treatment or total destruction. This book, which is based on a symposium by the Division of Environmental Chemistry of the Amencan Chemical Society, focuses on detoxication of hazardous waste as an alternative and/or an addition to storage and total destruction techniques.
Wastes can be detoxicated by chemical, physical or biological tech niques. These methods can also be used to modify wastes destined for landfill 6r total destruction by incineration. Preferably, detoxication allows recovery and reuse of the valuable chemicals in hazardous waste. Detoxication techniques are generally carried out in small and econom ical equipment; therefore, treatment can be carried out at the location where the waste is generated or located. The portability of detoxication equipment should allow iu use during cleanup of abandoned dump sites. Detoxication of contaminated soil is especially attractive because in cineration or landfill disposal is so expensive. Suitable soil detoxication procedures would be ideal methods for cleanup of spills.
In a democratic society, hazardous waste is understandably as much a political as a scientific issue, and legal, social and political issues do afTect
xiii
HONS 221565
the technical solution* that can be applied to solve pollution problems. There it no "typical waste," and there are thousands of toxic chemicals. Our present legalistic industrialized society hat attempted to characterize hazardous wattes rigorously without much concern about the degrees of hazard. Hazardous waste under RCRA is defined as those materials that are igmtable, corrosive, reactive or toxic, Ignitable wattes are those that can give off heat, smoke and particulates, or disperse toxic pollutants and by-products through the environment. Corrosive wastes are those that can cause injury to tissue, or. through destruction of containers, be released to the environment, Reactive wastes are those that can detonate or give ofT toxic gases by reaction with water or air. Toxicity is the most elusive criterion used in classifying hazardous wastes. The U.S. Environ mental Protection Agency (EPA) extraction procedure (EP toxicity) requires that chemical concentrations in the extract do not exceed the National Interim Primary Drinking Water Standards by more than 100. This definition assumes dispersion of the pollutant through a landfill into groundwater and is limited to well defined chemicals. Toxicity of chemical wastes must take into account the acute and chronic effects of chemicals. Generally, acute (short-term) criteria for oral, inhalation and dermal toxicity are considered to be death in humans at low doses, dermal LDm (rabbit) of leu than 200 mg/kg, oral LDm (rat) of less than 50 mg/kg, inhalation LDm (rat) of leu than 2 mg/1, or any serious irreversible illness. The impact of chronic (long-term) toxicity effects poses exceedingly difficult questions because of uncertainties surrounding the no-effect level, a concentration threshold below which no carcino genicity, mutagenicity, teratogenicity, or plant and animal toxicity exists. A great deal of controvery surrounds the concept of a threshold to toxicity. Consequently, risk assessments must be earned out to estimate the potential for harm due to the discharge of a waste to the environment. Also, of course, there is a direct correlation between the degree of concern over a pollutant and its detectability, persistence, degradation, migration or bioaccumulation in the environment.
In the final analysis, however, society decides which chemicals are toxic. The chapters in this book focus on polychlorinated biphenyls (PCB) (which were specifically regulated in the United States in 1979 under the Toxic Substanees Control Act), priority pollutants specified in the Clean Water Act of 1977, and the hazardous constituents associated with RCRA. The detoxication methods described in this book are designed to convert wastes or specific constituents in the waste to residues that present a reduced risk of health or environmental danger and which are more acceptable to society.
The book is divided into four sections: incineration and waste manage
xiv
HONS 221566
ment; treatment, recovery and destruction of PCB; a case study of the destruction of dioxins; and the biological detoxication potential of genetic engineering, microbial and enzymatic techniques.
In the United Stales, treatment of hazardous wastes at regional waste management centers is a common and economical disposal method. Major improvements in capability and degree of detoxication can be achieved by the integration of various chemical engineering unit opera tions with multipurpose thermal oxidation complexes. Consequently, the new waste management complexes are much more sophisticated than existing facilities. In addition, typical engineering operations (such as carbon adsorption, distillation, steam or air stripping, precipitation and coagulation, and biological treatment) are combined to pretreat, detoxi cate and recover waste constituents. Stabilization of inorganic wastes is necessary before landfilling, to reduce their environmental impact, but the general applicability of stabilization suffers from poorly conceived testing procedures and public misconceptions. Incinerators are the heart of regional waste management facilities and, until recently, little hard scientific information was available about efficiency of destruction and chemical processes within the burning chamber, RCRA hat affected the design of hazardous waste incinerators by requiring specific destruction and removal efficiencies. At the moment, there is considerable debate about ranking the incinerability of hazardous compounds. Nevertheless, incineration of wastes to carbon dioxide and inorganic constituents offers the most flexible, economical detoxication methods for a wide variety of nonrecoverable hazardous wastes. In addition, incineration allows energy recovery as useful heat. However, considerable public opposition to new incinerators presently exists. One reason for concern is the potential emission of toxic combustion by-prod ucu such as polychlorinated di oxins and furans. Any understanding of the chemical processes, stability of hazardous wastes and performance characteristics of various inciner ator designs could demonstrate the effectiveness of thermal oxidation and thereby alleviate public concern.
In 1979 concern over the stability of PCB led to stringent restrictions on the incineration of PCB. When PCB disposal was mandated, regu lations prescribed greater than 99.99% destruction by oxidation above 1200C for more than two seconds. Yet, approval of PCB incineration facilities was not granted until the question of polychlorinated dibenzodioxin and dibenzofuran emissions had been addressed. This question had been raised by scientists who postulated the formation of poly chlorinated dibenzodioxins during any combustion of chlorine-contain ing fuels. Sophisticated analyses of vent emissions during test bums of PCB at two incinerators in 1981 provided experimental data on dibenzo-
xv HONS 221567
dioxin tnd -funn emissions. Risk analyses of the emission of low concentrations of chlorinated dioxin and furans on human health sug gested low potential hazards. Subsequently, the incinerators were ap proved by EPA for disposing of PCB under the conditions of the test burns.
During this same testing period, a number of other PCB destruction processes were explored. Actually, PCB detoxication illustrates the diversity of possible approaches to treating a specific type of waste. The large number of processes can serve as a model for detoxication of other pollutants. Ocean-based, molten-salt, diesel and cement kiln incineration were proposed and tested. Plasma arc and other high-temperature processes were explored. PCB-coniaminaied waste oil was burned in high-efficiency boilers.
Detoxication of PCB-contaminated transformer fluids provides a splendid example of the benefits of detoxication in recovery of valuable chemicals. After PCB are removed from transformers, replacement fluids become contaminated by the slow leaching of residual PCB. The resulting transformer fluids generally contain less than 500 ppm of PCB. Several approaches to removing PCB from these fluids have been proposed, tested in pilot plants, and two are in commercial operation. The first approach uses anion radicals, such as naphthyl sodium, to abstract chlorine from PCB to form dechlorinated coupling products and salt. Two processes based on this approach are available in mobile units. A second approach uses superoxides of sodium polyethylene glycoxide to perform nucleophilic displacements on PCB. A third method dehydrochlorinates PCB by exposure to ultraviolet light. All of these processes apply fundamental chemistry of halogenated aromatic hydrocarbons to solve environmental problems and to recover valuable chemicals. The ultimate fate of all PCB in the environment is degradation by micro organisms and exposure to sunlight.
In the United States, detoxication of high concentrations of PCB, such as pure PCB or its mixtures with trichlorobenzenes, is geared toward destruction, despite the loss of large quantities of chemicals. In other pans of the world (e.g., Japan), different economic criteria and social values lead to a different approach. Extensive work by the Japanese on the reduction of PCB by hydrogen in the presence of metal catalysts appears to be achieving the goal of convening PCB to high-quality, useful diphenyl.
Social values, political judgments and legal requirements play major roles in any attempt to detoxicate hazardous wastes. No compounds, other than perhaps PCB, have achieved the public recognition and fear of the polychlorinated dibenzodioxins, often described as the most toxic
xvi HONS 221568
synthetic chemical known to man. This class of compounds, an impurity formed during preparation of chlorophenols, achieved notoriety during the Vietnamese war and because of several industrial accidents. The most serious of these incidents, a release of a reactor contents containing about 2 kg of tetrachlorodibenzodioxin (TCDD), led to the evacuation of the Italian town of Seveso in 1976. It seems appropriate, then, to describe a case study of a project that destroyed 7 kg of TCDD in a complex, hazardous waste. The experience gained during this project can be used as a model for other detoxication projects. The technical success required a multidisciplinary effort of organic and analytical chemists, chemical engineers, toxicologists and industrial hygienists. The destruction process was implemented by technical people working closely with lawyers, doctors, government regulators, politicians and the public. In addition to serving as a model, this project teaches one other important point: the technical expertise exists to solve even the most difficult pollution problem. However, the societal or corporate will to solve the problem must be asserted.
Microorganisms in'biological activated sludge systems have long served to degrade organic chemicals in aqueous waste streams. The application of selected microorganisms to detoxicate pollutants in hazardous waste or contaminated soils, lagoons or groundwaters is generating a great deal of interest. In addition to selected mutation of microorganisms, the potential for developing new pollution control technologies by genetic engineering is exciting. Enzymes also can offer sufficient catalytic activity to allow the use of otherwise slow chemical reactions in the detoxication of pollutants.
In summary, disposal of hazardous waste presents varied problems that can be addressed by detoxication procedures. The fundamental know ledge to carry out detoxication exists, but it must be adapted creatively to specific problems by chemists, engineers, microbiologists, physicists, geologists, toxicologists and many others working together, lmplemunration of the solution requires interaction with nonscientific members of society, value judgments, decisions about risk levels and potential conse* quences, and political realities. We can solve the problem of hazardous waste if we, as a society, have the will and make the commitment.
xvii HONS 221569
SECTION 1 INCINERATION AND WASTE MANAGEMENT
HONS 221570
CHAPTER 1
HAZARDOUS WASTE DETOXICATION AT CONTRACT WASTE MANAGEMENT FACILITIES
c. Youngson IT Enviroscicnce Concord. California 94520
J. Fwrier* IT Corporation Martinet, California 94553
This chapter focuses on hazardous waste processing technologies at existing and future contract hazardous waste management facilities. The IT Corporation Northern California Treatment System Complex (NCTSC) is described to illustrate hazardous waste detoxication* technologies used in an existing facility. This facility represents existing application of technology and employs a broad spectrum of detoxication and treatment techniques, ranging from incineration to chemical treat ment of wastes. The IT Corporation Ascension Parish Hazardous Waste Management Facility (APH WMF) illustrates integrated hazardous waste detoxication techniques under design for a future contract hazardous waste management facility. This facility, which will be the most tech nologically sophisticated regional hazardous waste detoxication facility in
''Detoxication** refen io trtntformaiion of toxic compound into lew toxic product; 'detoxification" it redunion in the degree of poitoning of *n organitm, tt in the detoxification of an inebriate [TJ.
HONS 221571
4 INCINERATION AND WASTE MaNaCEMENT
the western world when completed in 1984, his received stite of Louisiini operating end federal construction permits.
The first section of this chapter deals with waste detoxication at the NCTSC; the second section deals with waste detoxication technologies planned for the APHWMF, Each section includes a brief summary of the appropriate facility at a whole, with emphasis on the treatment tech nologies employed and their integration. These summaries are followed by discussions of each major treatment technology by unit operation. Emphasis is placed on the expected or proven performance of various technologies w'tth limited discussions of equipment design parameters. In addition, the importance of integration of technologies for efficient detoxication of a broad spectrum of wastes will be discussed.
HAZARDOUS WASTE DETOXICATION TECHNOLOGIES AT NCTSC
NCTSC is an integrated operation designed to detoxicate, destroy, treat or dispose of > 80 million gal/yr of industrial hazardous wastes generated in Northern California. The complex meets many of the w>aste treatment and disposal needs of area industries by processing wastes that industries cannot handle themselves, and consists of a treatment facility with solar ponds in Martinez, California, and a landfill with ponds in Benicia, California.
A variety of waste management technologies are used tn the complex, ranging from incineration of hazardous w-aste vapors and liquids to landfill of inorganic sludges. The design and operating philosophy of the facility is to recover useful chemicals {primarily oils) and energy values (combustion of waste solvents to generate steam) from wastes, to destroy toxic materials such as phenols, sulfides and cyanides, and then to dispose of remaining residues in a secure landfill or solar evaporation ponds.
Figure 1 is a simplified flow diagram showing the interrelationships between major segments of the NCTSC. The main processing facility, located in Martinez, California, includes all operations shown in Figure 1, except for the Benicia landfill and several solar evaporation ponds. The Martinez facility, which includes suppon facilities such as a laboratory, maintenance shop, and utility supply and distribution systems, has the appearance of a typical chemical processing plant.
After passing a predisposal selection process, liquids or slurries are received at Martinez, and solids, at Benecia. Examples of the type of wastes normally received at the NCTSC are listed in Table I. The wastes primarily are delivered in 5000-gal vacuum trucks, logged in and
MOMS 221572
c o n tr ac t w aste m a n a g e m e n t f a c ilit ie s
HONS 221573
incineration and waste management
Tibi* I, Industrial Wails Caleforlea Protetatd at NCTSC and Representative Examples
Group
Classification
Example
1 Aqueous Inorganic Liquid
N on metallic salts
Na,S04. NaNO,
Acid HF. HNO). HjSO. H,P04
Acid with heavy metals
HNOj + Fe(NOj)j
Alkali
NaOH
Alkali with heavy metals
NaOH + lead
Cyanide
NaCN, KCN, Cd(CN>,. ZnfCN),
Reactive (bleseh, sulfide)
Mercaptana, HjS, NajS
Brine II Aqueous Organic Liquid
NaCI
Biodegradable organic
Acetone. MEK. eeette acid
General organic
Phenol
Organic and heavy metals
111 Organic Liquid
Light hydrocarbon
Hexane, gasoline
Hydrocarbon with water
Jet fuel
Chlorinated hydrocarbon
Not accepted
Polychlorinated aromatics
Not tcccpted
Other halogenaied hydrocarbons
Not accepted
Other tubttituted hydrocarbons
Mercaptane
Oil (heavy hydrocarbon)
Crude oil with light ends
Organic with heavy metal
Ter with nickel catalyst
IV Slurry/Sludge (Liqutd/Solid)
Organic/organic
Waste oils
Organic/heavy metals
Aqueous/heavy metals
Cooling tower sludge with chromium
Aqueous/inorganic non metallic
Aqueous calcium carbonate
Aqueous/ biological
Biologfcai treatment plant sludge
Organic/inorganic
Oil spill cleanups
Aqueous/ organic
Aqueous amines
V Solids Organic
High-moieniiar-weight sleohols
Inorganic
Spent ealeiumchloride dryingegent
inorganic with organic
Used iiwulaiion
Heavy metal
Spent catalysis containing metals
Contaminated trash
Empty chemical bags
Organic heavy metal
HONS 221574
CONTRACT WASTE MANAGEMENT FACILITIES 7
analyzed. Based on the results of this analysis, an appropriate treatment method is selected, and the waste is discharged to storage, treatment tanks, the landfill or ponds. Analysis and treatment evaluation tests are performed in a laboratory facility equipped with appropriate analytical instrumentation and bench-scale testing equipment.
Most wastes delivered to Martinez require pretreatment before ultimate disposal at Benicia or in solar evaporation ponds. These wastes are processed in the pretreatment and recovery units of the Martinez facility. Wastes amenable to oil or chemical recovery are treated by conventional operations, such as filtration, settling, drying, evaporation and chemical reaction. These treatments yield oil and solvents usable as fuel. Wastewaters from these operations are placed in solar pond* for evaporation. Organic sludges are landfilled in Benicia.
Aqueous wastes containing phenols, mereaptans, sulfides, cyanides or organic solvents are processed by multipurpose equipment typical of the chemical industry. Organic solvents and other volatiles are stripped from aqueous wastes by air and/or steam. Phenols, mereaptans and sulfides are oxidized by hydrogen peroxide to less hazardous compounds. Cyanides are oxidized by chlorine to carbon dioxide and nitrogen. Sludges are partially dewatered by gravity thickening in lagoons and vertical tanks to reduce aqueous loads to the landfill.
An incineration complex consisting of two high*teAiperature thermal oxidation trains is the major energy recovery/vapor emission control system for the Martinez facility. The primary incineration system (incineration 1) is used to destroy vapors collected from treatment operations and holding tanks, waste solvents, waste oils, and other combustible and pumpable waste liquids. The much smaller incineration II backs up the primary system, and is used primarily to incinerate vapors collected from waste holding tanks.
Finally, pretreated wastewater generated onsite and certain aqueous wastes received at the site are deposited in solar evaporation ponds. As water evaporates from the ponds, the remaining solids concentrate and are removed and placed in the Benecia landfill.
Not all of the treatment and disposal processes mentioned above are truly waste detoxication technologies. All, however, are required to yield an effective economical contract waste disposal facility. Thus, the technologies employed at the facility and the manner in which they are interconnected yield effective, economical waste treatment. The waste detoxication technologies at NCTSC fall into the categories of waste pretreatment/ recovery and incineration. Technologies falling into the former category are air/steam stripping, chemical treatment (oxidation, neutralization), solvent recovery and oil reprocessing.
HONS 221575
S INCINERATION AND WASTE MANAGEMENT
Watte Pretreatment/Reeovery
The pretreatment and recovery systems operate in a batch mode and fractionate and/or detoxicate certain types of wastes to yield nontoxic residues and usable products. (Figure 2 is a schematic of the various systems.) The principal types of wastes directed to the pretreatment and recovery systems include dilute aqueous wastes, aqueous-organic liquids and organic liquids (see Table 1). These wastes are either sent directly to the appropriate detoxication technology from vacuum trucks or trans ferred to the appropriate treatment system from onsite storage tanks.
Aqueous wastes from, pretrcatment/recovery operations are sent directly to solar evaporation ponds or processed through the air/steam sparging system and subsequently sent to ponds as the lab analysis dicutes. Organic/inorganic residues are ultimately landfilled at Benecia, and organic products are sold or burned in the incinerator.
Vapors from storage, treatment or handling procedures are collected in the vent system and burned in the incinerators. Steam is generated by combustion of these gases and organic waste liquids and is used in the solvent recovery unit and the air/steam sparging unit.
Chemical Treatment
Cyanide Treatment System. The cyanide treatment system is designed to remove cyanide from liquid wastes by converting free cyanide to carbon dioxide and nitrogen gas and by precipitating combined forms of cyanide. The process involves chlorination. pH adjustment and precipi tate removal.
There are two types of cyanides in the majority of the waste cyanide loads received at the Martinez facility: free (CN* ions in solution) and combined (e.g., ferrocyanide complexes) cyanide. Oxidation by chlorine at pH 10 converts all free cyanide and most combined cyanide to the cyanate form, which is much less toxic than the original cyanide. This cyanate subsequently is further oxidized at pH 8.3-9 in the presence of free residual chlorine to CO: and N:. The only combined cyanide that is not readily oxidized even by excess chlorine is sodium or poussium ferrocyanide. This complex, because of its stability, is not excessively toxic and is removed by precipitation at pH 5.3-6.0.
A simplified flow diagram of the cyanide destruction system is shown in Figure 2, The system consists of (l)a batch cyanide treatment unk and recirculation pump, and (2) sodium hydroxide, sulfuric acid and chlorine storage and delivery systems. The cyanide treatment tank is connected to the main vent system to collect gases (CO:, N': and sometimes N'Hi) and
MOMS 221576
CONTRACT waste management FACILITIES f CTtfm TtungiT Tin HlIU Nd
Mil M
*"" Utrnmr mm (Ml
*tUI
H lw lw.
m rr"f",i,g nm
Flfvr* 1. NCTSC pretrutmcm end recovery tyeicm*.
HONS 221577
1* INCINERATION AND waste management
to control inadvertent hydrogen cyanide evolution if the solution becomes acidic.
Hydrogen Peroxide Oxidation. The hydrogen peroxide unit is used on a batch basis to oxidize phenols and sulfides in aqueous wastes. Phenol is oxidized by hydrogen peroxide at pH 6-7 to volatile organic acids and ultimately to carbon dioxide and water with a ferrous sulfate catalyst. At alkaline pH, sulfides are oxidized by hydrogen peroxide to water and sulfates.
Figure 2 shows a simplified flow diagram of the hydrogen peroxide oxidation unit. All tanks are connected to the vent control system, so that any vapors released during oxidation will be incinerated rather than emitted to the atmosphere. Sulfide-containing and phenol wastes are unloaded directly into separate treatment tanks. If a wastewater is excessively acidic, an appropriate amount of caustic is added. Once pH adjustment has been completed, the appropriate amount of hydrogen peroxide and ferrous sulfate are metered into the treatment tanks to achieve the desired oxidation. Treatment tank contents are recirculated during hydrogen peroxide addition to ensure rapid mixing and, thus, uniform oxidation. Such recirculation also occurs during tank pH adjustments. On completion of oxidation, treatment tank contents are air/steam sparged to reduce volatiles or discharged directly to solar e'aporation ponds.
Neutralisation. Aqueous acids, such as 25% HNOj, H1SO4, HF and HjPO<. are received onsite in 5000-gal vacuum trucks and stored in lined, horizontal steel tanks. The acids are metered from these tanks to treatment tanks containing appropriate amounts of caustic. Vapors emitted during neutralization enter the vent system. Neutralized waste water is normally sparged with air/ steam to remove volatiles and sub sequently placed in solar evaporation ponds.
Solvent Recovery System
The solvent recovery system (SRS) is a batch system designed to recover high-quality burnable solvent from waste solvent loads con taining too much water and/or solids to be burned directly. The solvent recovered by this system is blended with other hydrocarbon fuels and burned directly. The system is designed to process hydrocarbon solvents and oxygenated hydrocarbons, but cannot handle chlorinated solvents.
The SRS is shown in Figure 2. It consists of a vertical, cone-bottom, waste solvent storage/feed tank, a solvent evaporator tank, vapor
HONS 221578
CONTRACT WASTE MANAGEMENT FACILITIES II
condensers, end an overheads receiver and associated pumps, piping, valves and vent collection equipment.
Solvent wastes are processed in the SRS on a batch basis. First, solvent wastes are loaded into the vertical cone-bottom tank. Solids settle in the tank's cone bottom and are gravity-fed to an oil storage pond and eventually landfilled. Second, a batch of solvent from the tank is drained by gravity and pumped into the evaporator tank. Solvent is evaporated by direct steam injection, condensed in the overhead condensers and col lected in the receiver tank. The contents of the reeeiver tank are then pumped to the incinerators for thermal oxidation. Water and sludge remaining in the evaporator are transferred to other tanks, where they are contacted with additional steam and air to remove trace levels of volatiles. Finally, the water is pumped to a solar evaporation pond.
Airj Steam Sparging System
The air/steam sparging system is used to strip volatile organic materials out of wastewater before ultimate disposal in a solar evaporation pond. The system consists of an air compressor, air and steam delivery piping, air and steam sparger nozzles, and two aeration/treatment tanks. The system is shown in Figure 2.
Oil Reprocessing System
This facility consists of a number of heated tanks, an evaporator (oil dryer) and a chemical treatment system. Equipment is designed to remove water from waste lube and slop oils, and break emulsions so that the oil can be reused as fuel. Heat is supplied to the evaporator and treatment unks by a recirculating hot oil system that uses waste oil as fuel.
Figure 2 contains a simplified flow diagram of the oil reprocessing operation. Pond and other slop oils are received by trucks and placed in a special pond. Oil is skimmed off the top of this pond, filtered, deemulsified and dried by heat application or chemical addition, filtered again and placed in an intermediate lank. The oil from this tank is blended with dryfiltered waste lube oil and waste black oil to make No. 4 fuel oil for sale.
Incineration
Two incinerators destroy hydrocarbon vapors collected from storage and treatment tanks in the vent system and waste organic liquids received directly onsite or recovered in the SRS system and the oil reprocessing
HONS 221579
11 incineration and waste management
facility. In addition, the incinerator produces steam to be used in the SRS unit and in the air/steam sparging system.
Vent System
The vent system is a closed system of storage and treatment tanks with associated piping that carries vapors from the tanks through venturi scrubbers to the incinerators (Figure 3). With incinerator 1 on-line, tank vapors and air (supplied through atmospheric dampers) are drawn into the incinerator by a blower. The atmospheric dampers are automatically opened once the scrubber blowers are energized and automatically closed after the scrubber blowers are secured. In-line, manually operated dampers are designed to meter air- and vapor flow from specific tank farm areas. Pressure/vacuum valves are situated on each vented tank and correct any high- or low-pressure conditions. Spark arrestors are installed at each vented lank and prevent vent line flashbacks from spreading to the holding, storage or processing tanks and eliminate the spread of potential tank fires or explosions,
Incinerator I
Incinerator 1 burns recovered waste fuels and vapors given off from holding and processing tanks. The heat produces steam in the boiler (heat exchanger) chamber, This steam production allows effective treatment of wastes containing high hydrocarbon vapor phase (HCVP) in the air/ steam sparger system and enables recovery of waste solvents and fuels in the SRS system. This incinerator is shown schematically in Figure 3.
The incinerator is designed to operate at combustion chamber tempera tures of 1500-2000F and flue gas residence times on the order of 0.5 sec. These conditions assure adequate destruction of the nonhalogenated hydrocarbon liquids and vapors.
Incinerator II
Incinerator II prevents toxic and/or air polluting materials from entering the atmosphere by incineration and caustic scrubbing of vapors drawn through the vent system. This unit must be running any time incinerator I is not operating. Incinerator II consists of the equipment shown in Figure 3.
HONS 2215S0
CONTRACT WASTE MANAGEMENT FACILITIES
INCINERATOR*l
HONS 221581
14 INCINERATION AND WASTE MANAGEMENT
HAZARDOUS WASTE DETOXICATION AT APHWMF
APHWMF will be a fully integrated operation to detoxicate, destroy or reclaim approximately 80 million gal/yr (350,000 ton/yr) of industrial hazardous wastes generated in the Ascension Parish, Louisiana, area. The site will be located in Ascension Pansh, Louisiana, on a 1000-ac site bordering the Mississippi River, but will occupy only 150 acres of the site. The facility will process a broad spectrum of hazardous wastes from local industry. These wastes will vary widely in physical and chemical proper ties. Table II lists the categories of wastes expected to be handled at the facility as determined by surveys of selected area industries. Table III lists typical compounds the facility is expected to process.
Figure 4 is a simplified flow diagram showing the interrelationships between major facility segments. The integrated nature of the facility is evident, with effluents, residues and energy from waste pretreatment, wastewater treatment and incineration being transferred from one process area to another to achieve destruction or detoxication of wastes in an economical manner.
Wastes will be received at the facility in the form of solids, liquids or slurries and, as shown in Figure 4, will be delivered to the plant, received, logged in, analyzed and stored. Based on analysis, an appropriate treatment method will be determined, and the waste will be designated for processing under rigorously controlled conditions by the most appro priate treatment operation. These analytical and treatment evaluation tests will be performed onsite in a modern laboratory equipped with sophisticated analytical instrumentation and bench-scale testing equip ment.
Many wastes will be candidates for pretreatment, either for recovery or to improve the overall economics involved in downstream processing of the materials. Wastes amenable to oil and/or chemical recovery will be processed using the conventional operations, settling, drying, distillation and chemical reaction, as required with steam generated by incineration of wastes in the incineration system. This procedure will yield oil that can be used to fuel the incinerators, lube-oil blending stock, and industrialgrade chemicals and solvents. Wastewater and organic sludges generated from these operations will be processed or destroyed onsite.
Aqueous wastes containing small amounts of hazardous pollutants will be pretreated by multipurpose equipment typical of the chemical pro cessing industry. The wastes will be processed by physical means (e.g., extraction, steam stripping or carbon adsorption), or chemical treatment methods. Wastewater effluents from these units will be processed in a wastewater treatment plant on site. Organic material will be incinerated.
HONS 221582
CONTRACT HASTE MANAGEMENT FACILITIES IS
Group 1
TibU II. AfHWMF WU|t profile
Classification Aqueous inorganic*
Percentage of Total H'aalt Represented by Each Category
0
II Aqueous organic liquids Organic (acid) Organic (alkali) Organic (sell)
Percentage of loial wane
17
III Organic liquids Light hydrocarbons Hydrocarbon with water
Chlorinated hydrocarbons Substituted hydrocarbons Oils (heavy hydrocarbons) Percentage of total waste
33*
IV Sludges Organtc/organic Aqueous/heavy metal
AqueOut/inorganie nonmctal Aqueous/biotogical
Organic/inorganic Aqueous/organic Percentage of iota) waste
46
V Solids Organic Inorganic Inorganic with organic Heavy metal Contaminated trash Organic/heavy metals
Percentage of total waste
J
Approximate total waitc(ton'yr)
330.000
'Includes 40.000 ton/year waste crankcase ind lube oil* from Ihc area.
Sludges will be dewatered and/or dried to reduce the aqueous loads on incineration equipment and, thus, reduce energy consumption. Equip ment planned for this service includes belt filters for dewatering dilute sludges and indirect steam dryers for further moisture reduction.
HONS 221583
It INCINERATION and waste management
Tibl HI. Typical Organic Chemical* Expectft to Bo NmhwI at AfHWMF
Aldehyde*/ Alcohol*/ Ketone* Acelaldehydt Methanol Methyl ethyl ketone
Chlorinated Aliphatic* Carbon tetrachloride Ethylene dichloridc Methylene chloride Trichloroethanc
Chlorinated Aromatic* ChlorOtolwcne Chlorobenzene
Chlorinated Olefin* Vinyl chloride
Aromatis Benzene Toluene
Amine* Dtpbenylamine Toluene diamine
Carboxylic Aad* PropionK Aad
Phenol* Phenol
An incineration complex of three high-temperature thermal oxidation trains is the heart of the treatment facility. A broad profile of offsite organic wastes plus onsite residues from recovery/pretreatment will be destroyed. Two large (90-million-Btu/hr) rotary kiln/secondary com bustion systems will receive solids, liquids, gases and slurries. The third specialty incinerator will receive a limited profile of pumpable wastes. One rotary kiln will be equipped with a heat recovery boiler for steam generation. The incineration units will have secondary combustion chamber configurations designed to provide a minimum residence time of 2 sec at 1000 or 1200C. Flue gas from each incinerator will be treated separately to remove particulates and acid gases before discharge. The four-stage, state-of-the-art gas cleaning technology includes wet scrub bing techniques (quench, venturi, packed bed) and wet electrostatic precipitation. Inorganic sludges and noncombustible materials will be
HOMS ZZ1584
CONTRACT WASTE MANAGEMENT FACILITIES
AQUEOUS 0HCAH1C LIQUIDS
otr.Aiiic
LIQUIDS
y vt'
wash. nfcf ic ANALYSIS AN) SionACE
fT /f
SLUDCtS
SOLIDS
pnctnEAiMEMt AiIMnciAcolKvcItnT
OTtAAIIONSl
. FnOOUCTS
ronsALE
__________________ -----------
f TICRMAL OXDATOTJ H/An noLLUtoN coNinoi.
U SYSTEMS)
exhaust to
ATMOSMRC NR AftNRMlT
$t AO(.ltAl ION AN) ----------------------SCCLflC LAEOFLL
oticn onsite
haste maters
wastewater
treaimcnt
IMU.TRII
omraismi
discharge to
MTSMSSPRl RHCR KA PERMITS
J-'Ijat* 4. SckcnaiK 4w|r* of the A PH WMF.
MONS 221585
IS INCINERATION AND WASTE MANAGEMENT
stabilized and confined in an onstte secure landfill along with inorganic residues and fly ash solids from incinerator flue gas cleaning systems.
Finally, treatment will be provided for wastewater generated onsite from all the processing units, in addition to site-related waters such as surface runoff and sanitary wastes. Treatment processes for different streams will include physical/chemical removal methods, such as clarifi cation, pH adjustment, carbon adsorption and activated sludge biological treatment, for pollutant destruction or removal. Treated, monitored wastewaters will be discharged to the Mississippi River. Other support facilities necessary for a complete and operable facility include such ancillaries as plant administration, personnel services, maintenance shops, fire protection, security, utility supply and distribution, and effluent/emission monitoring.
Pretreatment and Recovery
The pretreatment and recovery systems include four primary process ing areas with different functions and equipment:
1. Aqueous wist* prcireatment includes seven! independent unit operations destined to remove or destroy selected pollutants in dilute aqueous wastes.
2. Sludge-slurry processing consists of equipment to remove water from sludges and slurries.
3. Chemical recovery provides equipment for frmcuonaiing organic liquid wastes.
4. Oil reprocessing is a complete multistage oil re-refining plant to convert venous waste lubricating oils to lube blending stock and fuel
Figure 5 is a simplified block diagram of the pretreatment and recovery system showing the four areas and major flows into, from and between these areas.
The pretreatment and recovery systems are necessary in the overall facility to:
improve ultimate disposal and treatment performance and reduce costs; increase effective overall facility capacity: reduce the use of purehtsed fuel for incineration; and reclaim valuable chemical constituents of waste mixtures.
In addition to processing offsite wastes, this system enables treatment of wastes generated onsite, such as waste-activated sludge from the biological treatment system and aqueous effluents.
HONS 221586
HllHH
rra FrffM* l*wf
rrttrNim
CONTRACT WASTE MANAGEMENT FACILITIES If
Tg B|ef H 1*11* k* 1 tbs 1ifAte> ei$gll IIggAA
nwuw~r'
anneii. imwm
Figure 5. APHWMF pretrcitment and recovery systems.
Aqueous Waste Pretreatment
The purposes of aqueous waste pretreatment are:
removal from wastewater of regulated pollutants that eannoi be removed by conventional biological wastewater treatment (resulting tn detoxication of the wastewater);
HONS
22158?
21 INCINERATION AND WASTE MANAGEMENT
prevention oT deleterious effects or ionic pollutants 10 ihe facility's biological wastewster treatment plant,
prevention of sir emissions or hiurdt caused by sewering volatile, flammable or odorous pollutants; and
production oT high-quality organic fuel fractions for incineration.
In general, the pretreatment area will receive Class 11 dilute aqueous wastewaters that are not effectively treatable by biological means (see Table 11). The wastes are expected to contain priority pollutants, e.g,, cyanide, heavy metals or toxic organics such as pesticides. Types of wastes may include very dilute slurries, emulsions and brines.
Technologies chosen to treat this variety of waste types include a selection of versatile, conventional unit operations that are applicable for removing pollutants from water. The four basic pretreatmcnl processes include:
I, steam stripping; 2> carbon adsorption wiihin-placc, nondestructive steam orsolvtni regeneration; 3, liquid/liquid extraction; and 4. emulsion breaking and chemical treat me nL
Each technology is discussed below in sequence, with emphasis on those that detoxicate/destroy hazardous wastes to yield less toxic wastewater.
Steam Stripper
The steam stripper will treat continuously up to 80 gal/min of aqueous streams containing organics that are moderately volatile and that range in concentration up to the organic solubility level. Due to the corrosionresistant construction of the stripper and associated equipment, aqueous streams over a broad range of pH values will be acceptable for treatment. However, streams containing a significant quantity of suspended solids or streams thal foam when heated will not be treated.
Feed will be transferred to the stripper column through a shell-andlube feed/bottoms cross exchanger (see top of Figure S). The feed will enter the stripper column where it will be contacted countercurrently with steam. Vapors stripped from the feed will pass into a shell-and-tube type overhead condenser where they will be condensed and then flow into a vertical decanter tank. Condensed vapors will either be refluxed back to the stripper column or incinerated. The unstripped portion of stripper feed will flow out the column bottom and be pumped to biological wastewater treatment via the feed/hot toms cross exchanger.
HONS 221588
CONTRACT WASTE MANAGEMENT FACILITIES II
Polluttnts with t Henry's ltw constant of 10 or more will undergo 99% or greater removal in the stripper. For pollutants with Henry's law constants close to 10, which require a higher steam-to-feed ratio, the feed rate to the stripper will be adjusted down to achieve corresponding treatment efficiency. Conversely, aqueous streams containing organics with Henry's law constants greater than 10 require a lower steam-to-feed ratio to achieve 99% removal and therefore can be fed at a higher flowrate to the stripper.
~Carbon Adsorption
The aqueous waste pretreatment carbon adsorption system is designed to treat up to SO gal/min of wastewater based on a typical loading range of 0.1 -0.3 lb of adsorbable organic per pound of carbon. The loading will vary considerably with the concentration of adsorbable compound, and adsorption and activated carbon characteristics. The loading could be much lower than 0.1 lb/lb without necessarily affecting the performance. An average removal of 99% of the adsorbable organic from the aqueous waste stream is expected.
The carbon adsorption system consists of carbon columns with auxiliary pumps, tankage and piping for series and parallel operation of the columns and for inplace solvent or steam regeneration of the carbon (Figure 5). Typically, wastewater is fed continually to one column until it is saturated with organics, at which point it is switched to regeneration. Throughput can be increased by operating the two columns in parallel and feeding batchwise. Treated wastewater from the columns flows to biological wastewater treatment. Organic compounds removed during regeneration are incinerated.
Solvent Extraction
Solvent extraction is a separation technique involving contacting a water-immiscible solvent with wastewater. A certain degree of separation occurs when some of the pollutant transfers from the wastewater to the solvent. Separation of the solvent from the extracted pollutant by distilla tion enables recycle and reuse of the solvent.
Aqueous wastes selected for extraction at APHWMF normally contain organics that exhibit a reasonable partition coefficient in typical extracting solvents. Compounds that are likely candidates for extraction generally will have low water solubility. However, selective solvents can be effective in removing polar, low-molecular-waight compounds, which
HONS 221589
11 INCINERATION AND WASTE MANAGEMENT
have higher water solubility. Solvent extraction will be used for treatment of aqueous wastes with solute concentrations from 10 to about 0.1%.
Solvent extraction will be carried out at APHWMF in three 8000-gal, jacketed vessels. The raffinate will be pumped to the stripper or biological wastewater treatment, while the extract will be distilled in the recovery section.
Emulsion Breaking and Other Chemical Treatment
Typical oil-water and water-oil emulsions can be deemulsified by altering one or more of the physical/chemical characteristics of the emulsion. Methods of deemulsification include temperature elevation, pH adjustment, or addition of acidic soaps or polyvalent salts. After an emulsion is broken, conventional physical separation techniques can be used to separate organic and aqueous phases and/or solids.
Wastes for emulsion breaking can include a wide variety of oil-in-water or water-in-oil mixtures. Solids often are dispersed in the emulsion. Examples of emulsions include pesticide-water mixtures, oil-water sludge mixtures from refineries and solvent-water-solid mixtures from tank cleaning or other processes.
Wastes for chemical treatment will vary significantly. Wastewaters containing fats, oils, ethers, acid sludges, pesticides and carbohydrates are typical candidates for acid or caustic hydrolysis. Wastewaters suitable for chemical oxidation may contain compounds such as cyanide, pesticides and sulfides. Chemical precipitation will treat wastes containing metals and most inorganic ions, although specific organic salts also may be precipitated. Various treatment methods and equipment are suited for wastewaters containing a wide range of contaminant concentrations. Emulsion breaking and chemical treatment are carried out in the same process equipment used for solvent extraction.
Sludge Processing
Dewatering and drying processes separate the solids ponion of sludges and slurries from the liquid (aqueous) portion. The resultant separated streams are much easier to dispose of than the original mixture. The dewatered and/or dried solids have a high enough fuel value and low enough water content that they can be incinerated readily in a rotary kiln. Without processing, aqueous sludges and slurries would require substan tial auxiliary fuel for incineration.
HONS 221590
CONTRACT WASTE MANAGEMENT FACILITIES IS
Dewatering
Sludges and slurries containing a low concentration of solids are subjected to two dewatering steps--thickening and belt filtration (see Figure S). The solids content is increased from below several percent solids to an intermediate range of 10-15% solids by separating and removing moy, if the liquid in these two steps. In the thickening step, 80,000 ton/yr of low-solids sludge, with an average solids content of 0.5-1.3%, is thickened to yield sludge with an average solids content of about 3-5%. This sludge is then processed by belt filter presses to yield moist sludge cake with an average solids content of 10-15%. The two-step dewatering process will remove 80-90% of the total water in the original sludge or slurry. An average of 98% solids retention is expected.
Drying
The types of sludges identified in the APHWMF waste profile as applicable for direct dryers are (I) dewatered, waste-activated sludge from offsite sources; (2) other dewatered primary wastewater treatment sludges; (3) primary, oily sludges from American Petroleum Institute (API) storage tanks and the bottoms from refinery API separators; and (4) powdered carbon wet cake containing traces of organic and inorganic contaminants. The solids content of these wastes may vary from 10 to 20%, depending on offsite treatment techniques. These materials will be combined with wastes from onsite dewatering and dried in indirect steam heated, jacketed dryers.
The dryers are sized to process about 80.000 ton/yr of high-solids sludges. They are horizontal troughs * ith rotating center shafts that drive attached paddles to agitate and recirculate the bed of dried solids in the trough. Heat is transferred into the moving solids through both the jacket wall and the walls of the hollow paddles. Up to three twin-agitator, Porcupine*-style dryers will be used. The dryers will produce a wet solid with 50-60% moisture. The consistency, melting point, thermal stability, presence of organics and moisture of the feed are major factors m the degree of drying that is appropriate.
Chemical Recovery
The purpose of the chemical recovery system is to;
recover end'or modify telecied waste* ifiht market or recycle value of vast* constituent* u greater than iheir potential value a* fuel to the incinerator
HONS 221591
14 INCINERATION AND WASTE MANAGEMENT
upgrade or separate selected wttitt streams to (hat the overall fuel will be enhanced, end
recover and/or purify the carbon tdtorption regenerant and the extraction tolvcnu front the pretreaiment section for reuse in that area.
In general, the chemical recovery system consists of two batchdistillation units and a wiped film evaporator. The system 1 distillation unit can carry out atmospheric batch distillations. The system 11 distilla tion unit is capable of carrying out vacuum and pressure distillation and continuous steam stripping. The evaporation unit can evaporate solvents and/or light hydrocarbon fuels from such viscous wastes as heavy tars and still bottoms or from contaminated solvents.
System 1 distillation has been designed to treat a wide variety of liquid waste mixtures, with emphasis on the organic liquid constituents identi fied in the waste profile (see Table 111 for example compounds). Wastes will be distilled if reasonably pure mixtures of the major organic constituents can be obtained economically by batch distillation and if a market for the products exists.
System II distillation is expected to handle the recovery of the carbon regeneration solvent and the extraction solvent from aqueous waste pretreatment. The bottoms produced from the recovery of these solvents will be transferred to the incinerator feed storage tanks for disposal.
An analysis of the available vapor-liquid-equilibrium and vaporpressure data for potential waste constituents indicated that the average reflux ratio required for batch distillation of all wastes is 2.0. The system is designed accordingly.
The evaporation process is sized to treat at least 1000 lb/ hr (20.000 lb/day) of wastes. The capacity for a given waste feed depends on various factors, such as viscosity, heat of vaporization and amount of solvent to be evaporated. The performance of the evaporation and distillation systems is linked with the overall performance of the facility only because it may change the waste load constituency to the ultimate treatment or disposal areas, especially the incineration area. Waste candidates will be chosen on the basis of recovery economics (product or fuel value). Evaporation processes such as those in this facility have been used for many years and are being used increasingly by generators (solvent users) and waste solvent reclaimers.
Oil Reprocessing
A separate system to reprocess 5--10 million gal/yr of waste oils will produce salable products from waste oils purchased from generators or
HONS 221592
CONTRACT WASTE MANAGEMENT FACILITIES 23
collectors. All residues nd effluents from waste oil reprocessing, which may contain hazardous materials, will be transferred, treated and dis posed of in the appropriate area of the overall facility.
APHWMF will receive two major types of oils. Industrial automotive crankcase and machine lube oils will be collected for recovering the lubeoil fraction as lube-oil base siock. Other slop oils, waste oils and oil-water mixtures will be processed to recover fuel values in the pretreatment (emulsion-breaking) incinerator or for potential resale, if removal of the bulk of water and suspended solids cannot be accomplished through phase separation in waste storage.
The APHWMF oil reprocessing system is a waste lube-oil re-refinery. A simplified flow diagram of the process is shown in Figure 5. The process begins with storage and settling and includes distillation steps to remove low-boiling contaminants, evaporation to remove high-boiling contaminants, hydrotreating for purification by removal of sulfur, chlorine and nitrogen contaminants, and a distillation section to separate the oil product into different viscosity grades. The various products are stored in appropriate tankage in the oil reprocessing area for shipment or transfer to incinerator feed storage for auxiliary fuel.
Incineration System
Purpose of the Incineration Complex
The purpose of the incineration complex is to completely destroy organic compounds by high-temperature thermal oxidation and then remove any resulting inorganic residuals from the flue gases as ash or scrubber water slurries/solutions. These objectives are achieved by applying the most advanced U.S. and European state-of-the-art combus tion and gas cleaning technolog}' available.
Incinerators 1 and 2 are nearly identical two-chamber rotary-kiln systems. Each has a rotary-kiln primary combustion chamber that is capable of handling containerized wastes in up to 85-gal drums, bulk solid wastes, pumpable liquid wastes, slurries and sludges. A secondary combustion chamber capable of handling pumpable liquid wastes follows the kiln. Incinerator 3 is a single-chamber system capable of handling pumpable liquid or slurry wastes with similar performance and air pollution control systems as incinerators 1 and 2.
The thermal oxidation systems in the APHWMFfacility consist of two rotary-kiln incinerators (units 1 and 2), a third, pumpable liquid/slurry incinerator (unit 3), and associated waste feed and flue gas cleaning systems. The waste profile used to design the complex required a nominal
HONS 221593
it INCINERATION AND WASTE MANAGEMENT
duty capacity of 90 million Btu/hr from each of the three incinerators. The waste profile consists of solids, liquids and sludges that must be balanced property to minimize use of auxiliary fuels and to optimize destruction efficiency. The waste pretreatment methods previously de scribed are a necessary part of the incineration operations for efficient treatment of an overall set of wastes similar to that shown in Table 11.
After wastes have been identified, categorized, and blended or segre gated, they are fed into the appropriate incinerator for thermal destruc tion. Incinerators 1 and 3 each contain a quench chamber that cools the gases, removes large panicles and washes acids from the flue gas. Incinerator 2 has a waste-beat recovery system after the incinerator that produces high-pressure steam before the gases enter the quench chamber. All three incinerator trains have sophisticated gas-clcaning systems that remove SOi, HC1 and submicron particulates. Following gas cleaning, each train has its own induced-draft fan and exhaust suck. Recycle and fresh makeup water are used in the quench and gas-cleaning systems, and purge water is sent to the heavy meuls removal system. Ash from the three incinerators is stabilized and landfilled.
Rotary Kiln and Secondary Combustion Chamber
The thermal oxidation (incineration) portion of the total system is designed into two separate chambers--the rotary-kiln primary com bustion chamber and the stationary-hearth secondary combustion chamber. The roury kiln is an ~ 1 l-ft-diameter-by-40-ft-long, refractorylined, horizonul, routing cylinder equipped with a variable-speed drive. There are burner nozzles for incinerating pumpable liquid or slurry wastes and a continual gas pilot burner to ensure a constant source of ignition. A combustion air blower and a pilot air blower provide air for combustion at the burner nozzles, and the overfire excess air is drawn down the feed chute into the kiln by the negative pressure created by the large induced draft fan at the end of the process (Figure 6).
Conuinerized and bulk solids are charged down the feed chute into the kiln by gravity through air locks. The liquid burners are fired cocurrentiy, and combustion products flow from the kiln into a refractory-lined mixing chamber and on into the secondary combustion chamber. Both ends of the kiln are sealed to minimize air leakage into the kiln. Ash and slag move slowly through the kiln, driven by the rotation of the cylinder, and fall out the end of the kiln into a water-filled ash quench trough. A drag chain conveyor moves the ash to a screen for separation into fine and oversize fractions. The fine fraction drops into a dumpster box for trans portation to the stabilization area, and the oversize materials (burned out
HONS 221594
CONTRACT r a s t i MANAGEMENT FACILITIES
(ICONOAKV CDMOUSTIDN C HAMM A. Him! ** ILqu>4
It tpnwtait ("'twnlw 110 3ft
I ftiuftll #n(,
MU rOLLUTtONCOHIItOLl Fow fltft oti
M mcfm-M >nMn tat MMni, MhOU, mwit: nO v*t riKtinr
Wtt ILICTH0ITATtC OAICIAITATOA
(ftOWOWUD makiup
watoa, _________
iftft-i t
'itttog trfiAdtr m Mntim
ItatM nft mIM mm (30 00 piMta* luAt mI
VIKTUAJ
I LTM--n.---
ttACK
AlCOVIAr AOIkOAl
Apwmv MWtff lm
Aiartiirti H m f iIiti
1
HftAVVMtTAkl AtMOVAk
pm am m IftOpUp
lMft ptap Oh Manita It
AlCYCkt VtAI(A ftYCTCM' TlltaMlMMMtapnO
Ft(ar f. Rotary kiln ihcrnwl otidpuon lyitem.'
MONS 221595
ZS INCINERATION AND waste management
drums and clinkers) drop into a dumpster box for transportation to the inert material landfill-
The secondary combustion chamber is made up of three separate sections. The horizontal section contains two waste liquid burner nozzles, > continuous pilot burner, a combustion air blower and an atomization air blower. The chamber is refractory-lined and is designed to receive the combustion gases from the kiln to complete the combustion process. The gases then flow from the horizontal section into the vertical section, which ensures completion of the combustion process.
Next, the gas retention section allows hot gases to further mtx and fragment. Completion of the combustion process is ensured by increased temperature, additional retention time, gas turbulence and flame contact.
The overall combustion system is rated at a nominal 90 million Btu/hr. Throughput is a function of the temperatures, excess air and combustible portion (organic carbon) of the waste. With the kiln operating at flue gas temperatures of I500*F and the secondary chamber at 1800* F, about 60 million Btu/hr are fired in the kiln and 30 million Btu/hr in the secondary chamber. The Btu/hr ratio is reversed, however, when the secondary is fired at 2200* F while the kiln is maintained at 1300* F, as would be necessary to meet guidelines for incinerating chlorinated aromatics. Increasing the operating temperature of the kiln is desirable to increase the quantity of solids and sludges handled by the system; however, tradeoffs exist, since increasing the temperature may rapidly shorten the life of the refractory due to the combination of heat and attack of salts and alkalies.
An average overall excess air level of 100% is designed into the system to promote complete oxidation and to provide a cushion for combustion surges such as those generated when bulk quantities of rapidly com bustible materials ure fed into the system. Most of the excess air is introduced into the kiln, where contact between combusting solids and air is not as efficient as contact between atomized liquids and air. The excess air level in the kiln is approximately 130%. Although the operating temperatures dictate the level of excess air, because air is a heat sink, water in the feed also acts as a heat sink and therefore reduces the level of excess air at a given temperature.
Flue Gas Cleaning System
The flue gas cleaning equipment is designed to meet Resource Con servation and Recovery Aet(RCRA) regulations for HCIand particulate removal. A pH-controlled scrubber is included to remove SO;. With the pH-controlled scrubber in the system, >99% HCJ removal is achieved. A
HONS 221596
CONTRACT WASTE MANAGEMENT FACILITIES If
venturi scrubber and wet electrostatic precipitators are incorporated for particulate removal.
After the quench chamber, the flue gases flow to a venturi scrubber. A pressure drop of 30-40 in. water column (w.c) is maintained over the venturi for optimum paniculate removal efficiency. A packed demister/ scrubber sized to remove wuer droplets, HCI and SOi follows the ventun. The water from the venturi and demister flows to another integral sump, where it is pH-adjusted and recycled to the venturi and demister. Fresh process water is also added to the demister through a distributor.
The driving force for moving flue gases through the entire system is provided by an 80,000-acfm induced-draft fan located behind the ventun/ demister. Three wet electrostatic precipitators connected in parallel remove any remaining submicron particulate matter from the flue gases. The cleansed gates leaving each of the three precipitators are combined and sent to a free-standing exhaust stack for discharge into the atmosphere.
The pH-adjusted overflow water from the quench sump and the venturi-packed scrubber/demister sump flows to the main sump. From there it is pumped to the heavy metals removal system. The sump overflow is the purge water from the air pollution control system and can be adjusted to maintain the desired suspended and dissolved solids levels in the recycle water systems.
Waste Heat Boiler
Incinerator 2 is identical to incinerator I except that it has a heatrecovery boiler located between the secondary combustion chamber and the quench chamber. The boiler is used to extract energy from hightemperature combustion products to produce up to 368-psig steam with 130 F superheat.
The energy-recovery technology that is being applied originated in Europe, where identical boiler systems have been in continuous operation for more than 15 yean on large chemical waste incinerators and several industrial processes. The waste heat boiler is a basic, water tube type. The peripheral boiler housing heat-transfer surfaces (walls) use natural circu lation for movement of the deionized boiler feed water. The internal heattransfer surfaces are arranged in the housing and operated by forced circulation of the deionized feed water. Forced circulation operation of the internal heating surfaces is necessary to accommodate heat-load fluctuations. The bottom of the boiler is designed as an ash discharge facility and made of tube-web-tube construction. It is designed to be cleaned manually during normal operation of the boiler. The steam drum
MONS 221597
3* INCINEKATION and WASTE management
is located on the boiler roof and has a reserve capacity of 10 min. The drum's internal baffles ensure that the steam quality is in accordance with the required steam quality specifications.
Rotary Kiln Incinerator Performance
The incineration process, including thermal oxidation and flue gas cleaning equipment, will meet the performance requirements of Louisiana law and the U.S. Environmental Protection Agency (EPA) RCRA incinerator standards published on January 23, 1981 (and proposed EPA incinerator standards). Compliance with current RCRA requirements includes achievement of. (1)99.99% destruction and removal efficiency (DRE) of organic constituents; (2)99% HC1 removal efficiency; and (3) particulate emissions of less than 0.08 gr/dsef adjusted to 12% CO;.
Stabilization and Landfill
The waste stabilization treatment process detoxicates inorganic chem> ical residues by intimately mixing them with a carefully compounded portion of treatment additives. The slurry sets into a rigid, inert rock>like cast within 6 hr to 3 days after compounding and mixing. This rock-like form, through physical and chemical interactions, binds into an inert mass and detoxicates the toxic or environmentally harmful species in the waste.
The inorganic waste stabilization process used at APHWMF can be described generically as a cement*pozzolanic solidification process. In this process lime, flne>grained siliceou* (pouolanic) material such as fly ash and cement are added to the waste in specific combination and sequence to achieve the best and most economical treatment for the specific waste being treated. A number of additional ingredients may also be used, depending on the type of waste being treated, to enable the process to achieve optimum end*product stability,
Function and Interface with Other Major Treatment Areas of APHWMF
Stabilization is the final treatment process at APHWMF for inorganic wastes *and/or inorganic residues (incineration ash, metals sludge from wastewater treatment) from onsite treatment facilities before the material is permanently interred in the secure landfill. Stabilization treatment converts the material to its least soluble and most environmentally men form. This stabilization is accomplished by improving the handling and
MONS 221598
CONTRACT waste management FACILITIES 31
physicochemical characteristics of the waste, decreasing the surface area across which transfer or loss of contained pollutants can occur, minimiz ing the solubility of any pollutants contained in the waste and detoxicat ing contained pollutants.
Stabilization facilities receive the bulk of waste to be stabilized in the form of ash from the incinerators and as heavy metal sludge from the wastewater treatment area. The ash is received in dumpster boxes, and the heavy metal sludge is received as a water slurry via direct pipeline and as a semisolid filter cake contained in dumpster boxes. Offsite materials destined for stabilization without pretreatment are routed directly to stabilization unloading stations after laboratory confirmation and accep tance procedures. Stabilized waste is transferred to the landfill by truck or pipeline.
The stabilization process is suitable for all inorganic wastes and organic-contaminated wastes that can be incorporated homogenously into an aqueous phase by dissolution, suspension or absorption. Gener ally, the maximum acceptable level of organics in the waste is a few percent by weight Plant policy is that organic wastes will not be treated by stabilization or interred in the landfill. The process is especially elective in treating all heavy metals, including arsenic and mercury and asbestos.
Stabilization Technology
The APHWMF stabilization process (Figure 7) is carried out on a batch basis. Liquid wastes are stored in tanks fabricated of appropriate materials. Bulk solid wastes are stored in separate bunkers. Raw materials used in the treatment process are stored in bunkers and storage silos and on pallets. The liquid storage tanks have agitators to prevent solids from settling and to maintain homogeneous mixtures in the tanks.
The first stage in the process is to blend, homogenize and pretreat a variety of wastes available from storage. In this way, interactions between the various wastes can be employed to bring the waste mix to the desired state before formulation of the treatment mix. After neutralization and pretreatment of reactive wastes, appropriate quantities of compatible liquid and solid wastes are blended in a stock pretreatment tank. Solid materials are passed through a crusher to reduce the particle size. Appropriate quantities of lime and fly ash are blended thoroughly to prepare the mixture for the final product formulation. At this point the mixture has a pH >9 and contains 10-40% total solids. The mixture must contain the proper ratio of solids io water so that adequate water of hydration is available for the solidifying reactions. The bulk of water
MOWS 221599
31 INCINERATION AND WASTE MANAGEMENT
Fl|itr 7. AM WMF ilabtlitalHM proccu.
to Land! Ill
i MOWS 221600
contract waste management facilities jj
needed is obtained by mixing in heavy metal slurry containing only about 2-4% solids from heavy metals treatment. After the stock is thoroughly blended, samples are taken and lests are run in the laboratory to determine the characteristics of the batch and the formulation necessary to produce a satisfactory Onal product. The prepared stock is then transferred to a stock feed tank.
Weighed quantities of premixed stock from the stock feed tank are mixed with weighed quantities of additives (fly ash, cement and proprie tary additives) in a batch mixer according to the formulation determined by the laboratory. The mixture is then blended by a high-speed shear mixer before being discharged to the product tank.
The prepared product is a thick slurry similar to wet masonry mortar. This slurry is pumped from the product tank directly to the landfill placement area via pipeline. At the landfill, the material is cast into a single monolithic mass containing about one week's production. In about 6 hr to 3 days the material converts to a rock-like mass. Rainwater falling on uncured material runs off the surface without affeeting the properties of the material. The placed material sets even if submerged in water. The placement procedure strives to produce a solid monolith to exclude environmental interactions with the placed materia). The larger the treated monolithic mass, the greater the proportion of the waste isolated from any environmental interactions.
Stabilization System Performance
The treatment performance of the stabilization process is measured by the characteristics of the stabilized waste product. The stabilized waste product has the following characteristics:
Physical appearance--ibe stabilised product sets lo form a hard, rock-like monolith. The material is nonflammable, nonodorous. nonputrescible and unattractive to vectors.
Permeability--ihe coefficient of permeability is ins than I lO"4 cm/sec. which it leal than concrete and equivalent lo compacted clay.
Leaehinf--the eoneewration of heavy metals in the leachate it typically less than 1 ppm.
Strength--ihe unconfined compressive strength is greater thin 200 pit. Density--the density of the stabilised product ranges 6J-IJ ib/fiV
Landfill
The APHWMF landfill is not used for detoxication of hazardous wastes, but simply as a repository for detoxicated inert residues. As such.
HONS 221601
14 INCINERATION AND waste management
it is not described here except to state that it is a secure landfill designed and operated to state of Louisiana and RCRA standards.
Wastewater Management Systems
The APHWMF wastewater management system will consist of seven areas designed to treat, detoxicate or handle specific onsite wastewaters. The seven major areas are shown in Figure 8 and can be categorized into four systems:
I a system for treatment of wastewaters contaminated with specific inorganic compound* tuck as metals (heavy metals removal);
2. t system for ireal mem of wastewaters contaminated with organic compounds (pretreatment, biological oxidation and carbon adaorption);
1. a system for handling stormwater; and 4. a system for retention of treated effluent until its suitability for discharge has
been prove* by analysts (final effluent handling).
All areas will be integrated to provide treatment flexibility, since on occasion wastewater or effluent normally containing only inorganic compounds may become contaminated with organics or vice versa. Only the first two areas, however, are described here, since they employ detoxication technologies.
Technologies to Detoxicate Wastewater Contaminated with Toxic Inorganics
The first treatment system, shown at the top of Figure 8, consists of heavy metals removal. This treatment area will process the largest volume of wastewater of any system (up to 2000 gal/min). It will be operated principally to remove 500-2000 ppm of dissolved metals and suspended solids from incinerator scrubber purge water. It will have the capacity, however, to treat other wastewater that may be contaminated with metals or suspended solids, such as landfill leachate and runoff. The major unit operations and detoxication technologies employed by this system are pH adjustment, fiocculant aid addition, clarification, filtration and sludge handling.
All waste streams feeding the heavy metals removal area first flow into a main sump. From this tump, wastewater is pumped through three evaporative cooler/ sulfite oxidizers and into a cooling sump. Cooled wastewater from this sump subsequently flows into a pH adjustment basin, where the pH of the wastewater is adjusted by addition of caustic or acid to precipitate metal hydroxides. Alum is also added to aid in
HONS 221602
CONTRACT WASTE MANAGEMENT FACILITIES
In ami wwra mul
Flg ft. Simplified flow diagram f APHWMF waMewaier ireumcM/hindkni ifMtm
HONS 221603
a incineration and waste management
flocculating the hydroxides. Wastewater from the pH adjustment basin is pumped mio iwo rapid-mix/flocculator tanks. Here it is combined rapidly with polymer solution to aid flocculation. The wastewater solution overflows inio the flocculation compartments of the tank, where flocculation of precipitated metal hydroxide particles is encouraged by the slow mixing action of flocculator agitators.
Thoroughly flocculated wastewater exits the rapid-mix/flocculator tanks by overflowing into one of two gravity clarifier/ihickeners. Floc culated solids settle to the bottom of the thickeners, and supernatant liquor, low in metals and solids, overflows at the top. On exiting the clarifier, the supernatant liquor flows by gravity through one of six sand filters, w'here practically all residual suspended solids are removed. A backwash stream flows from the filters to the pH adjustment basin to keep the filters clean. Wastewater exiting the sand filters is expected to be of acceptable effluent quality in all respects, i.e., leas than 5 ppm total suspended solids (TSS), and less than Louisiana state water discharge limits for toxic metals. It will, however, be detained in holding tanks until ns suitability for discharge has been eonfirmed by analysis.
Metal hydroxide particulate and other suspended solids removed from wastewater in the clarifiers will be thickened in the clarifier thickening section. Some of this thickened sludge will be pumped directly to stabilization, and the remainder will be filtered in a plate-and-frame filter press. The filter cake will be transported to stabilization.
Technologies for Detoxication of Organic-Contaminated Water
Process Sewer Pretreatmer.r. Aqueous wastes from the process sewer will be pretreated before they entpr the biological wastewater treatment system. The wastewaters expected to enter process sewer preireatment come from operations such as tank cleaning, building and equipment washdowns, laboratory testing and sample analysis, truck washouts, and other miscellaneous operations. These wastewaters will pass through an oil/water/grit separator (see Figure 8, second line) and enter one of two holding tanks. Water contained in such a tank will be analyzed to determine ns treatability. Depending on the analytical results, wastewater normally will be pumped to biological treatment. However, it also may be pumped to aqueous wastes preireatment, where unit operations such as steam stripping, carbon adsorption, solvent extraction or chemical treatment will be used to remove nonbiodegradable and purgeabie organics.
HONS ZZ1604
contract aste management facilities jt
Sanitary Sewer Treatment, Sanitary sewage from lavatories, change rooms and toilets will be degraded in a packaged biological treatment unit shown on the third line of Figure 8. Effluent from the unit will be disinfected with ozone and then discharged into the biological wastewater treatment system.
Biological Wastewater Treatment System
The primary "end of Ihe line" organic wastewater treatment unit at APHWMF is the biological wastewater treatment system, Wastewater from various areas will be detoxicated to reduce degradable organics, biochemical oxygen demand (BOD) and suspended solids. The principal unit operation of the system is an extended aeration activated sludge system. Ancillary unit operations include equalization, neutralization and waste sludge thickening as shown in Figure 6, second train.
Oxygen transfer and mixing will be provided by a submerged aeration system. Static aerators will be mounted on the bottom of each aeration tank on approximately 8-ft centers. Air will come from three blowers, and the flow to each aeration tank will automatically be adjusted by a modulating valve controlled by the dissolved oxygen concentration in the individual tank. Nitrogen required for the biological treatment process will be supplied by metering 50% aqueous urea solution into the neutralization tank. Phosphorus required for biological treatment will be supplied by metering 85% phosphoric acid into the neutralization tank.
Thickened sludge will be removed from the bottom of the clarifier by a suction withdrawal mechanism and will be pumped to the aeration tank distribution channel. Thickened waste-activated sludge (WAS) from the sludge thickener will be pumped to the WAS holding tank or to sludge dewaiering/drying for dewatering. Supernatant from the sludge thickener will How by gravity to a supernatant wet well and will be pumped to the equalization tanks.
Garified effluent from the secondary clarifiers will (low into either of two check tanks. These check tanks will retain clarified effluent for a sufficient time to determine if it has been treated adequately. If it has been treated adequately, it will be discharged into the final effluent handling check tanks. If it has not been treated adequately, it will be pumped to tertiary carbon treatment for final polishing.
The biological treatment system wilt process up to 400,000 gal/day of wastewater containing 1000-7500 ppm of BOD and produce an effluent containing 50-225 ppm of BOD.
MON3 221605
31 INCINERATION AND WASTE MANAGEMENT
Tertiary Carbon Treatment
The tertiary carbon treatment system is to be used on an as-needed basts to treat off-specification aqueous effluents from all other wastewater treatment systems. The system is designed to treat an average of 400 gal/min of wastewater through two carbon columns operated in parallel. The quantity of wastewater that each carbon column can effectively process depends on a number of factors. The most important factors are the types of organics in water feeding the column and their concentra tions, the dynamic loading of organics at the breakthrough point, and the concentration of suspended solids in the feed. The design case is for a total organic concentration of about 20 ppm in effluent feeding the columns, suspended solids concentrations of 20-160 ppm, and a con servative dynamic loading of 0.01 lb total organics/ib carbon at breakthrough.
Stormwater Impoundment
The third major handling system shown in Figure g is the stormwater impoundment area. This system will consist of devices to segregate, convey, store and analyze rainwater to determine its appropriate disposi tion, and then dispose of it by discharge to final effluent handling or to one of the treatment systems discussed above.
Final Effluent Handling
The remaining system shown in Figure 8 is final effluent handling. Treated effluents from heavy metals removal, stormwater impoundment and biological wastewater treatment are contained and held in this area for up to 12 hr until analysis indicates their suitability for discharge or need for retreatment, If retreatment is needed, the combined effluents will be pumped to a quarantine tank in the tertiary carbon treatment area. If the treated effluent meets permit standards and is suitable for discharge, it will be monitored and then combined with uncon laminated riverwater, clarifier underflow and noncontact cooling water. This combined stream will then be discharged to the Mississippi River.
SUMMARY AND CONCLUSIONS
The present detoxication technologies of the NCTSC facility include air/ steam stripping, chemical treatment, solvent recover}', oil reprocess-
MGNS 221606
contract waste management FACILITIES 39
ing and incineration. Detoxication technologies described for the future (APHWMF) faciIny include steam stripping, carbon adsorption, solvent extraction, chemical treatment, sludge dewatering/drying, chemical re covery, incineration, stabilization and wastewater treatment.
The technologies planned for future facilities are extensions or im provements of those currently used. For example, the steam stripper described for the future facility performs a function similar to the air/steam sparging system of the current facility, but is much more efficient. Similarly, the solvent recovery system of the future facility is much more efficient and sophisticated than that of the present solvent recovery system. In addition, the integrated nature of the future facility is an extension of the current facility, since such integration is essential to applying waste detoxication technologies economically to hazardous waste management on a contract basis.
REFERENCE I. Jakoby, W. B. "Detoxication Enzymes," in Enzymatic Basis of Detoxication,
Vol, /, W. B. Jakoby, Ed. (New York: Academic Press, Inc., 1980), p. 2.
HONS 221607
CHAPTER 2
CHEMICAL PROCESSES IN THE INCINERATION OF
HAZARDOUS MATERIALS
W. Tiang and W. Shaub National Bureau of Standards Center for Chemical Physic* Chemical Kineties Division Washington, DC 20234
The underlying phenomenon associated with incineration is a series of complicated chemical changes. Historically, however, the subject has been dominated by physical considerations and the experience of long practice. This is hardly surprising, since the conversion of a complex, ill defined conglomeration of principally organic substances to light gases and ash is not a process that lends itself to detailed chemical considera tions. Furthermore, in the absence of environmental regulations or energy constraints, hardly any chemical expertise is necessary. Recent events [1] mandating incineration as a primary disposal tool for hazardous wastes and the possibility that hazardous substances may be formed in combus tion processes[2,3] suggest the necessity for a closer look at the chemical basis of incineration. Such information can lead to prediction or at least classification and thus ultimately to the appropriate strategies for mea surement, abatement and foundation for new approaches. This approach can mean important savings in terms of proper measurement method ology as well as decreased needs for large-scale testing.
This chapter will begin by giving a qualitative picture of how a large polyatomic molecule breaks down under incinerator conditions from the
41
MONS 221608
41 INCINERATION AND WASTE MANAGEMENT
point of view of elementary processes. Wc next attempt to make these concepts quantitative, first in terms of thermodynamic equilibrium and then from > more detailed consideration of the rates (or at least the relative raies) of the pertinent elementary processes. We will pay partic ular attention to sources of data and the availability of estimation schemes. These coneepts will then be applied to chemicals that are of interest in a hazardous waste context. Finally, we will lm a number of unanswered questions and suggest certain types of experiments that will help provide a proper methodology and data base for design and opera tional purposes in the incineration of hazardous wastes.
REACTION MECHANISMS
If one considers the decomposition of a complex polyatomic molecule in the hostile environment of an incinerator, the baste processes are stepwise breakdown of the molecule to smaller and/or oxygenated species together with the alternative possibility of buildup to large species culminating in soot formation. Figure 1 gives a pictorial description. In a sense, the incineration process can be characterized as a race between destruction of reactants to smaller species and the side reactions yielding unwanted products. The individual elements that govern these trans formations are the elementary reactions. These are processes that occur as written, in contrast to global reactions (such n 7 Oj + 2BrjC}HjCI -- 4HBr + 2HG + 6COj + 2H;0), which express the chemistry of the combustion in terms of the overall conversion. Treatment in this form is appropriate only if the rates are assumed to be infinitely fast or as a basis for an empirical analysis of experiments. Only through elementary processes can one derive the type of general picture that is transferable to all conditions and systems. In seeking a more general solution, the required information base is correspondingly increased. Nevertheless, because one is dealing with elementary processes, the possibility of extrapolation and interpolation is enlarged. Furthermore, all elementary processes are not equally important in any given process; thus, identifi cation of key reactions can lead to simplification. Finally, we note that the treatment of combustion processes in terms of elementary reactions is and has been for many years the state-of-the-art [4],
In terms of elementary' processes and for present purposes there are only two broad classes of reaction types: unimolecular and bimolecular. As evidenced by the name, the former is represented by processes of the type:
Hi -- produei(i)
HONS 221609
CHEMICAL PROCESSES O where the rite of destruction can be written as dHz/dt = -kgntHz. Bimolecular reactions deal with the attack of reactive species on a molecule:
R * Hi -- produci(t)
and the rate of destruction is now dHz/dt s -k*(R)(Hz), The former is conceptually the simplest of all kinetic processes. It involves a molecule at a particular temperature having sufficient interna] energy so as to cause rupture of its bond(s) within the time scales of the experiments. The rale constant k,,,,j is a fundamental property of the molecule itself, in the same sense as infrared spectrum or boiling point. Unimolecular reactions can be classified in terms of bond rupture, complex fragmentation and isomerization processes [5].
Fljurt I. General mechanism Tor the ditmtcfraiion of polyatomic molecule under incineration conditions.
HONS 221610
44 INCINERATION AND WASTE MANAGEMENT
For present purposes we will be interested primarily in the firs. :o reaction types. Within these groupings, related molecules behave in a consistent manner. Structural characteristics control molecular stability, thus providing a basis for prediction. Under certain circumstances, unimolecular reactions can have a pressure dependence [6], The nature of this phenomena is well understood, and if the pressure-independent behavior (at sufficiently high pressures) is known, appropriate corrections can be made. For ail except ihe smallest of molecules, we do not believe that this phenomenon is of major importance under incineration condi tions. The situation with respect to bimolecular reactions is made more complicated by the multiplicity of possible reaction species. Thus, the rate of destruction depends on the constituents of the reactive systems, as opposed to the situation for unimolecular processes, where only the physical properties, principally temperature, are of concern. The two distinct types of bimolecular reaction of interest are addition and metathesis [5], The former leads to the formation of larger species and is related to unimolecular reactions through the equilibrium constant. In certain cases, addition leads to a sufficiently thermally hot molecule (chemical activation) and a subsequent cracking step occurs. This phe nomenon also can be handled within the context of unimolecular rate processes. Metathesis is concerned with the transfer of an atom or group of atoms from one molecule to another. As in the unimolecular situation, structural features govern reactivity, thus providing a basis for prediction.
EQUILIBRIUM CONSIDERATIONS
The earlier discussion has been developed on the basis of considering the incineration process from the viewpoint of elementary reactions. As has been indicated, the present data base is insufficient for derivation of a complete solution. In this and subsequent sections we will attempt to summarize existing data and indicate how they maybe used in the present application. Thermodynamics permits a powerful zero-order description of any system. Results are rigorous, assuming that equilibrium is achieved. Al the very least they set important constraints on the range of possibilities. Furthermore, the data base is available, and the procedures for calculations are well established and have been used widely in combustion contexts. The data base given by Stoll and Prophet [7] represents the essential source of all thermodynamic data on atomic, diatomic and small polyatomic species. For the larger polyatomics there are two outstanding compilations, by Cox and Pilcher [8] and Stull et al, [9], More importantly, with the existing values as a basis, it is possible to estimate with high accuracy the ihermod>namic properties of practically
HONS 221611
chemical PROCESSES 45
Tabk I. Cakukatrd and Littnturt Vlui for Hub of Formotion of Substituted betutn**
-CH,
-a
-F
Subtlllutlon Cak,
Lit.
Calt.
Lit.
Cak.
U.
1.3.31,2,4-
UJI.2J.4!.2.3.5I.2.4.JPent*.
Htxa*
-2.73 -3 15 -3.74
-10.22 -10.64 -10 47 -J7.72 -24.53
-2,26 0 29 -3 31 0 26 -311 0 33
10.02 -10,71 -10.12 -17.10 -20.75 0.62
2 II 0 41 -0 02 -1 95 -3 05 -3 65 -5 09 -6 14
-1.6 * 2.3
-m.39 -1)4 46 -III 79 -150.52 -154 22 -153 59 -111.21 -193.59 0.35 -220,97 -221 49 0.29
Tabk II. Thermod;nsrate Fundtom for lJl7,8*Tclrachlorodib<nx<p*dloiln
eol/(molt*K)
keol/molt
rit)
200 291.16 300 400 500 600 700
soo
900 1000 1100 1100 1300 1400 1500
c;
40.95 56.67 56.14 69.94 SO.39 11.53 94.11 99.17 103.15 107.06 109 61 111.15 113.66 1 IJ.JS 116 47
s*
94.75 114.tl 114.46 132.67 149.44 164.15 179.00 192.00 204.00 215.12 225.45 235.09 244.11 252.59 260.59
72.45 13.02 13.21 93.33 102.90 111.96 120.54 121.67 136-31 143.71 150.67 157JI 163.65 169.70 175 49
Hf-H& AH?
4,46 9.27 9.37 15.74 23.27 31.74 40.92 50.67 60.B6 71.41 12.25 93.33 104.61 116.05 127 64
-11.13 -12.49 -12.50 -12.17
-12.91 -12.94 -12.71 -12.51 -B2-2I -81.77 -11.27 -80.72 -80.19 -79.67
-79.16
-51.34 *46.67 -46.43
-34.33
-22.11
-10.02 2.12 14 23
26.30 38.34 50.31 62.25 74.15 16.00 97.10
Lot K,
63.735 34.199 33.115 11.755
9.694 3.651 -0,662 3.116 6.386 -8.377 -9 995 -11.335 -12 463 -13 423 -14 247
alt polyatomic molecule*. In view of current interest in polychlorinated aromatics, we have been estimating the thermodynamic properties of many such compounds [10]. Table 1 summarizes estimated heat of formation data for a number of halogenated species and comparisons with direct determinations. It should be noted that at higher temperatures (of interest for incinerator operation), accuracy requirements for energy quantities are much less severe than for ambient conditions. Table 11 is a typical JANAF-type [7] data sheet for 2.3,7,8-tetrachlorodibenzo-p* dioxin. With such information and appropriate ancillary data from the literature, heat of combustion and adiabatic flame temperatures can be
MONS ZZlblZ
44 INCINERATION AND WASTE MANAGEMENT
computed. More significantly, one can calculate the equilibrium distribu tion of species for arbitrary temperature, pressure and initial composinon. Our calculations for a variety of the polychlorinated aromatics indicate that at temperatures tn excess of 500C, the reaction is thermody namically complete. Except for greater stability with increased chlorin ation there is no single compound with special stability characteristics.
The fact that much higher temperatures are required in practice to effect destruction shows that at the lower temperatures at least, equilib rium is not achieved and the reactions are kinetically controlled, This does not rule out the possibility that in certain subsets of the entire system local thermodynamic equilibrium is in fact achieved. This local equilibra tion should be particularly true for small inorganic radicals, which can undergo fast reactions with each other. This assumption is widely used in the analysis of combustion systems, and we will employ this as a means of estimating radical concentrations at high temperatures. Furthermore, as implied earlier, coupling thermodynamic information with the rate of reaction in one direction permits, through detailed balance, calculation of the reverse rate. Finally, thermodynamic properties of stable compounds are the basis for calculation of transition state properties leading to predictions of mechanisms and rates [11,12]. They are thus the quanti tative basis for high-accuracy structure-reactivity relations.
QUANTITATIVE ASPECTS OF DECOMPOSITION PROCESSES
In the most general terms, the destruction of a hazardous waste Hz in an incinerator can be described by the relation
-dHz/dt . k.JHz] * <Ikk(Rj[Hz] i
here Ln * untmolecultr rate for decomposition ku * bimoltcular rate constant Tor aitack of speeic R, on Hz.
Rearranging, we can write
Hlf
r
S -dHz/Hz in Hz,; Hzf > J* [kH^ * (Sk^RjJdt
Hi) o i
where r is the residence time in the incinerator. The U.S, Environmental Protection Agency (EPA) requirement for 99.99% destruction efficiency is equivalent to setting a value of 9.212 for the logarithmic term in the relation, Within this context, the problem becomes one of finding the conditions where the integral involving kuni, Sk^R, and T is in excess of 9.212,
HONS 221613
CHEMICAL PROCESSES 47
Consider first the situation where unimolecular processes are the predominant mode of decomposition. In this case, assuming a reasonably uniform temperature situation and the usual incinerator residence time of approximately 1 sec, and since 9.212 < kuni = Am exp(-E./RT), we arrive at the minimum temperature as tabulated in Table III. A.and E. values given here cover virtually the complete range of such values.
Study of the rates of unimolecular decomposition processes has long been a favorite pastime of chemical kineticists. Outstanding collections of information are given by Benson and O'Neal [11] and Robinson and Holbrook [6]. Comparison of the data in these reviews and the numbers in Table 111 clearly demonstrates that under the stated incinerator conditions, most of the organic molecules will decompose on the basis of thermal stability considerations alone. In view of the large literature, one expects direct determinations for a number of hazardous materials. In other cases, the existing data can be used for extrapolation and predic tion. An examination of the situation with respect to the rates of cleavage of a single chemical bond is instructive. In this case, two reactive radicals are formed. Since the activation energy for recombination is known to be negligible, the bond dissociation energy is the activation energy for dissociation. The relationship between this quantity and chemical reactiv ity has focused important research efforts in this direction. For the present purpose it is sufficient that extensive tables of such quantities [13-16] or the equivalent heats of formation of the radicals exist. A typical sampling can be found in Table IV [14-18]. When this is combined with the experimental observation that the preexponential factor per bond broken is in the range of 10ls-10l6-J/sec. where the range of values increase from dissociation, to polyatomic * atom, to polyatomic * diatomic, to polyatomic polyatomic, one can determine readily from Table III the approximate conditions to achieve the appropriate destruc tion limits. Furthermore, except for resonance stabilization effects.
TaMe III. Temperature (*K) Nternary lo Assure 99,99% Dtstnjciloa Assumlnf Uniaolecuier Mechanism end Arrhenius Rets Expression
[k * As cspC-Eh/RT)] for Incinerator Residence Time of -1 te
E. flicsi)
(/t)
40
54
49
70
80
90
100 l
to11 792 990 lltl 1386 1584 1782 1980 2178 I0IJ 726 90S 1089 1271 1453 1634 1815 1980 10'' 670 831 1006 1173 1341 1509 1676 1844 I0,s 622 778 934 1090 1245 1401 1556 171J so1* SSI 727 S72 1017 1163 1308 U53 1599 to1' 5i5 6S1 818 954 1090 1226 1362 1499
HONS 221614
41 INCINERATION AND WASTE MANAGEMENT
Xun
TtbU IV. Some Typical Bond Encrfict of Polyaloml* Compound* [I4-II]
Radical!
CH,
jCjH, <CH. CiH,(vinyl) C)Hj(allyl) C*H, CH,CH, CH,CI CHClj CCI, CHjO C,H,0 CHjCO NHj
H F a Br I OH NH, NO, NO CH,
104 109 84 70 56 91 17 60 44 8S
100 83 70 55 93 16 60 44 87
97 10* 3 70 55 93 17
46 86
96 84 71 55 96 IS
45 12
us 99 61
107
90 72 56 12
77
HI 125 95 0 64 110 104 70 52 100
S9 44 II
so
102 79
99 77
96 70 56
32 IS
104 44 44 41 IS
7 so
17 III S3 67 50 I OS 99
16
107 65 S3
substitutions to the bond being broken it positions greater thin a hive very little consequence on the bond dissociation energies. Thus, the range of compounds covered in such i listing is fir lirger thin the compounds directly involved.
For the present purposes, primiry interest is focused on the fistest process that will destroy i molecule. In the framework of unimoleculir decompositions, complex fragmentations (where simultaneous cleavage and formation of bonds occur) frequently provide a low-energy channel for decomposition, in comparison to direct breaking of a single bond. Our understanding of complex fragmentations is considerably less than for direct bond breaking. As was the case for bond-breaking processes, an important factor to remember is that these reactions involve localized properties. Thus, except for substitution near the reactive sue, rate parameters can be considered to be invariant.
As an example of these ideas, consider the situation with respect to a w'ide variety of chloroalkanes as summarized in Table V. The primary mode of decomposition is the four-center elimination of hydrogen chloride to form the appropriate alkene. In contrast, the bond cleavage reactions involving C-C and C-Cl bonds are all in the neighborhood of SO keal. This lowered activation energy more than compensates for the twoorder-of-magnitude drop in A factors. Thus, molecular elimination is the primary decomposition mechanism. Note particularly the similarities in rate parameters for the decomposition of a particular type of alkyl chloride molecule. This trend is carried over to the bromides and iodides.
HONS 221615
CHEMICAL PROCESSES 49
Txblt V. Ri Etprtulont (/**) for th DtcompoiHlon of Alkyl Chloride* [111
c,H,a -- CjH HO nC,H,a " C,Ht HCI nC,HfCl " C.H, * HO
iCjH,C1 - C,H, * ho - C(H, * HCI
iC,H,CI - CH, HCI (CjH*a - C(M,, * HO
I0l34jexp(-55.000/RT) I0,3*exp(-55.I50/RT) 10,3,xp(-56.5OQO/RT)
lO'3*xp(-51.IOO/RT) 10,4xp(-50.600/RT>
1013 *exp(-45.000/RT) I0l3'exp(-M.000/RT>
We next consider bimoleculir chtnnels for hazardous chemicals de struction. The greater complexities inherent in this situation have been discussed earlier. Indeed, it is not possible to examine this problem with the same rigor as in the unimolecular case. However, it is possible to make some reasonable estimates. The basic model that will be considered is that of a high-temperature oxidative system at equilibrium, and we seek to estimate the lifetime of a thermally stable molecule in this environment. The equilibrium hypothesis, which should be of considerable validity, immediately yields species concentration. Of particular concern are OH, O and H concentrations. These are the most important high-temperaturereactive species, in the sense that most larger radicals are thermally labile and/or less reactive. Figures 2 to 4 represent equilibrium H, OH and O mole fractions at various temperatures at 1 atm and equivalence ratios of 0.5, 1.0 and 2.0, respectively. It is immediately clear that, with respect to bimolecular removal, attention must be focused on H and OH attack. The lack of accurate high-temperature rates for these processes introduces another uncertainty into these considerations. However, OH attack on organic substrates is one of the key processes in tropospheric chemistry. Thus, there is a large data base of information at room temperature, from which certain inferences can be drawn. It should also be noted that since incineration of hazardous wastes is usually carried out with large excesses of air, the OH contribution to bimolecular destruction must be quite important.
Two publications 17,18} have summarized the current state of knowl edge on rates and mechanisms of OH attack on organic substrates. From a mechanistic viewpoint there are two processes to be considered: addition and abstraction of hydrogen atoms. For the former, under incineration conditions, the overall process must also involve fragmen tation subsequent to addition. Table VI represents a sampling of recent information of OH reactions with organic compounds at or near ambient conditions. With respect to addition, the salient feature is the electrophilic nature of the OH attack on the unsaturates, leading to drastic lowering of
MONS 221616
st incinuution and waste management
Ftgvn 2. Equilibrium OH. O *ixt H mok friniom it ] itm prtwurr Tor wochio-
metric (# * 1) reaction with CH (----- )
-) in 5% CJ*
the ntes with increasing halogenation. With respect to abstiaction, the strength of the bond being broken obviously is an important factor. An empirical equation [19] has been proposed that directly relates rates with bond dissociation energy. Thus, the bond dissociation data summarized in Table 111 clearly are of greater applicability than merely for the prediction of unimolecular decomposition rates. It should be noted that the OH abstraction reactions under discussion all involve H-atom transfer. This is because for the halides, the overall reaction process is too endothermic Another factor that makes the OH data useful is that, as far as addition is concerned, it tracks 0*atom processes [6]. Thus, on a relative basis, these two processes can be lumped together. To use this information at incinerator conditions, accurate methods for extrapo-
MONS 22X617
CHEMICAL PROCESSES 51
Fipirt 3. Equilibrium OH. 0 and H mole fractions ti I tm pressure for fucMean (O * 0.J) resetion wiih CH(--) and C,H*(----- ) in 5% Clj.
lation are needed. The temperature dependence that has been determined covers very narrow ranges near ambient, and the accuracy of projected results at the higher temperatures is therefore uncertain. One does note, however, the difference in the directions of the temperature dependence in the sense that the addition processes usually have negative activation energies. In other words, the rate goes down with temperature. Probably a more appropriate functional form is a (1/T)n dependence. Furthermore, there is increasing evidence that for OH abstraction reactions there is a positive curvature in the Arrhenius plots. In general, one would expect that addition processes will be slower than abstraction under incineration conditions.
We next consider H-atom processes [19.20]. We have noied previously that, under most hazardous waste incineration situations, the presence of
HONS 221618
Si INCINERATION AND WASTE MANAGEMENT
Figure 4. Equilibrium OH and H mole fraction* at I atm pfuture for fuel-neb (0 2.0) reaction with CH*--) and C^H^---) in J%Cij(0-atom mole fraction ii leu than lO-*).
excess air makes it unlikely that it will be of importance. However, in the presence of mass transfer problems, substances may well pass through oxygen-deficient environments. Hydrogen atom abstraction reactions are characterized by higher A factors and activation energies than compar able OH reactions. The consequence is that, at incineration temperatures, their rate constants are close to that for OH attack. The general trends for H abstraction are dependent on the appropriate C-H bond dissociation energy. With respect to addition, H atom rates at room temperature do not follow the general trends characteristic of OH attack. Indeed, variations appear to be small. The equilibrium concentration of H atoms in air-lean systems is lower than OH concentrations in air-rich situations (see Figures 2 to 4). The consequence ts that destruction rates will be
HONS 221619
CHEMICAL PROCESSES S3
Table V], Typical Raiaa of OK Attack on Or{inlc Sutniritta [4]
Compound*
CH CjH* nC|H|f iCgH iq CH,F CHjCI CH.CIj CHClj HCHO CHjOH CHjCHO CHSH CHjNHj
Rate Const. i IS*K
(liter/mol-Mc)
5 4E6 1 6EI 1 IE9 1.7E9 IE7 2.2E7 9E7 SE7 7.2E9 6ES 9E9 1-tElO I.2EJ0
Rate Parameter*
A (Utar/mot-aac)
E (kaal)
2.4 X 10* 1.1 x I0,# 1.4 X 10* 4 a x io*
3600 2400 1000 769
i.t x to*
240Q
24 x I0,#
6 x 10* --
4.2 x 10* 5.4 X 10*
6 X 10*
2254 175 --
-510 -790 -455
c,h CjH* 2CH,
J.6E9 I.6EI0 4.2E10
7.2 X 10* 24 X 10'*
6 X 10*
-900 -1100 -1100
CHjCHQ CHClCHjCl C,C1* C*H* C*F
4.2E9 I.1E9 IEI 9ES 1.3 El
6 X 10* 3 X 10* 6 X 10*
-100 -900 2400
slower. For the same extent of conversion one expects that an increase ot at least 150K is required.
A direct consequence of the above is a model involving hazardous waste destruction of the more thermally labile compounds by unimolecular decomposition and the more stable components by radical attack. An estimate of the temperature that divides the two classes of compounds can, in conjunction with the data in Table 111, give some idea of the compounds belonging to each class. Figure 5 represents equilibrium OH mole fraction at various equivalence ratios and chlorine concentrations. To within a factor of three, this can be represented by:
OH - I0-1-' etp {*33.000/RT) mo)/1
If we now examine the data on the rates of OH attack on organic substrates, we can estimate that, at incinerator conditions, bimolecular rate constants will be of the order of 10*11 liter/mol-sec. The consequence is that to obtain the pseudo-unimolecular rate constant of 9.212, we need a temperature of the order of 1230K. If one now considers the results from Table III, it is seen that for bond cleavage reactions, unimotecular
MOMS 221620
54 INGNEJtATION AND WASTE MaNACEMENT
Fleur* 5. Equilibrium OH conctniraiion for various reaction condition* a* a func tion of temperature. A * CH* * * 1.0, CJ; * 0%; B * CH4, * 1.0. Qj * S%i C CH*. * * 5. Gj SRi D C,H*. * = 1.0. Clj * 0%: E * C*H. * * 1.0,
Cl! * 5%. decomposition will be quite important for compounds with their weakest
bonds in the 80- to 85-kcal range. This range covers many of the larger
organics with their numerous aliphatic C-C bonds. Since the rates of most known complex fragmentation processes are faster than comparable bond dea\age reactions, molecules with such decomposition channels will also decompose via ummolecular mechanisms. Thus, radical attack is of major importance only for a limited class of compounds: specifically, simple aromatics and other unsaturated molecules without organic substituents, and the simplest one- or two-carbon saturated systems.
The present treatment can be extended simply to the problem of the production of hazardous waste during combustion if one extends the
HONS 221621
CHEMICAL PROCESSES 55
criteria of 99.99% destruction to requiring similar extent of decomposi tion for the products that are formed. In general, this requirement will mean the use of slightly larger ummolecular rate constants as the criteria that must be met, perhaps of the order of *^20 to take into account the fact that products have residence times half that of the reactant. This assumes a constant rate of product formation from a precursor.
APPLICATION TO HAZARDOUS MATERIALS INCINERATION
The model that has been developed is a very idealized one. Aside from the assumptions that have been described, the analysis has been carried out on the basis of completely homogeneous gas-phase systems. Direct application is rendered uncertain by the neglect of mass- and heat-transfer effects. Thus, a molecule trapped in a particulate matrix may not be heated to the incinerator temperature or be attacked by a reactive radical. The most effective use of such information will occur in situations in which such effects may be cancelled out. A likely possibility is the setting up of a scale of incinerability and providing guidance for the kind of "test bums" that can qualify the operation of an incineration for a whole range of other compounds. This possibility will be especially true for systems with well defined unimolecular channels for decomposition, since the temperature necessary fo 99.99% conversion with a I-see residence time provides a well defined parameter. The lack of accurate high-temperature information on OH and H rates makes calculated relative numbers of such processes somewhat uncertain. For the present purposes, we believe that OH reactivity is of greater importance, and the appropriate variables should be C-H bond strength and (in the case of addition) extent of halogen substitution. On this basis Table VIJ gives a ranking of some hazardous organic compounds [21]. It should be emphasized that for the fuel-rich systems, where H-atom reactions are important, chlorinated aromatics.may be less stable in companson to the pure aromatics. This difference emphasizes the provisional nature of the ranking and indicates the need for additional high temperature rate data on such processes.
EPA has issued interim regulations for the burning of hazardous waste [1]. A suggested procedure for proof of the satisfactory performance of hazardous waste incinerators involves the selection of the principal organic hazardous constituents and the demonstration of 99.99% destruc tion efficiency for these compounds. It is thus highly dependent on the proper estimate of incinerability. EPA representatives have more recently [22] suggested a ranking based on heat of combustion. The rationale
HONS 221622
M INCINERATION AND WASTE MANAGEMENT
Tab)* Vtt. Inclnrrabtllly Ranking* of Some Haurdou* Compound* [II]
Rank
Compound*
Rationale
Rank (AH,comb)
I Hcxachlorobenzene 2 Penischlorobenzene 3 Chlorobenzene 4 Benzene 3 Naphthalene 6 Vinyl chloride
7 Chloromethane 1 Ethylene diamine 9 Dichlorophenol 10 Resorcinol II Chlorotoluene 12 Formaldehyde 13 Acetaldehyde 14 Acrolein
All C*H bonds in excess of HO heal. C*a bonds ~95 kcal; OH addition is major deatruction mode and is dependent on substituents on unsalurated structure
C-H bonds are in the 90- to 95-kcal range; all other bonds are greater than 10 kcal; assume that OH abstraction is controlling
9 7 26 31 37 20
13 33 16 24 29 2) 25 30
13 Dimethylphthalate
Bond breaking processes in
16 Meihylethyl ketone
the 60- to 10-kcal range;
17 AUyl alcohol
uiumolecular decomposition
IS Chloroform
is controlling mechanism
19 Bromomethane
20 Dinilrobenzene
21 Tn nitrobenzene
22 Tribromomethane
23 H ezachloropropene
34 H euchloropenudiene
23 Bromoacetone
26 Hydrazine
27 Methylhydrazine
2t 1 ,2-DiehlorocthaM
Low energy pathway through
29 1 J-Dichloropropane
complex fragmentation into
30 H exachlorocyclohcxane
stable molecules: A. -- to11-
31 Dl-n-butylphthalait
IOM/*ec, E - 43-SS kcal
31 Ethyl carbamate
33 1 <2-Dibromo-2-ehloropropana
34 Mcthyliodide 33 1.2-Diphenyl hydrazine 36 Nitroglycerine 37 >-Nitrosodiethyl amine 31 2-Butanonc peroxide
Fragmentation into radicals brought about by very weak bonds; 40-33 kcal range. A-factor > 10IJ/*ec
`The compound* are divided into group* purely for present convenience, when one conliden >11 the compound* in the EPA lining there will obviously be many overlaps.
MONS 221623
CHEMICAL PROCESSES 57
behind this ranking is that i higher heat of combustion requires a higher flame temperature and presumably a greater capacity to consume itself. The connction between flame temperature and heat of combustion is, of course, not necessarily true. It also must be pointed out that in the particular application in mind, a mixture is being burned; thus, this "driving force" is never manifested. Indeed, through control of auxiliary fuel and equivalence ratios, temperature is a variable that can be adjusted. Furthermore, heat of combustion is a thermodynamic quantity and is definitely not a parameter associated with the activation process that controls molecular stability. A very straightforward way of demon* strating the inappropriateness of the heat of combustion for this purpose is to cite the fact that a variety of explosives, near explosives and propellants (nitroglycerine, trinitrobenzene, hydrazine) are more difficult to destroy than most of the organic compounds in the listing. For example, benzene and polynuclear aromatics are considered among the easiest compounds to incinerate, and the limits of incinerability are almost completely set by benzene and hexachlorobenzene.
The ranking that has been presented here is vastly different from that proposed by EPA. It makes no claim with regard to exact quantitative accuracy, It would displace the listings of compounds supposedly difficult to decompose that are ranked ahead of hexachlorobenzene, simply because most of these will decompose by unimolecular processesat lower temperatures. They will be placed behind benzene. Nitro, nitroso and peroxide compounds are considered among the most labile due to their weak C*N, O-N and N-N bonds. Basically, there is very little concordance at all between the two rankings, except for the greater difficulty to be expected for the incineration of increasingly chlorinated aromatic com* pounds. Unfortunately, we are not aware of any bum data that can resolve these discrepancies. They are, however, so large that it should not require many experiments to differentiate beteen the two scales,
The present analysis suggests that in terms of the hazardous wastes given in the EPA tabulation, aromatic compounds (particularly the polychlorinated variety) are the most difficult to bum. The capacity to destroy such species is indicative of conditions that can easily destroy other compounds. Indeed, the usual presence of low-energy unimolecular decomposition channels makes most hazardous materials rather easy to destroy, and for systems free of chlorine, considerably lower temperatures can perhaps be used. Nevertheless, it should be pointed out that all of the above is based on extrapolations and interpolations. Direct experimental verification would be useful. Of special importance are high-temperature reactions of radicals with aromatic systems. Furthermore, since aromatic compounds are the inevitable by-products of combustion situations, a
MONS 221624
si incineration and waste management
better understanding of how such compounds are formed could dictate the proper strategies for prevention. The above also holds for the effect of chlorine, both with respect to the effect in aromatization or the chlorine* tion of such substances. All of this, of course, is intimately tied to dioxin and related problems. Without some degree of information on mechan* isms and rates, the only alternative is to raise continually the incinerator temperature. In terms of material capabilities, additional environmental problems and costs, there are definite limitations.
In terms of direet experimental verification of scales of incinerability, we believe it is possible to devise laboratory-scale experiments that can mimic actual burn conditions. The work of Duvall et al. [23] represents an excellent start in this direction. However, interpretation of such results must be handled with care. Thus, although the general trends with respect to stability and chlorination on the aromatic structure agrees with our expectations, this agreement may well have been brought about by decreasing amounts of hydrogen in the system. This hydrogen decrease has the effect of drastically lowering OH concentrations and leading to a less `'hostile*' environment. What is needed is exploration of the full range of conditions, in terms of C/H and equivalence ratios, likely to be en countered during incineration.
In view of the present conclusion that unsaturated chloride* are probably the most difficult organic substances to incinerate, a detector that can detect such compounds in real time would prove to be an ideal instrument for monitoring of completeness of hazardous waste incinera tion. It should be emphasized that throughout the course of this study, we have discovered no special features with respect to the stability of the most loxic chlorinated dioxins or benzofurans either from a thermo dynamic or kinetic point of view. One would therefore question the necessity of carrying out expensive determinations of the presence of individual isomeric compounds.
REFERENCES
). Incineration Standard* for Owner* and Operations of Hazardous Waste ' Management Facilities, Interim Final Rule and Proposed Rule; 40 CFR 122,
264, 265 Jan. 23, 1981 pr. 7666-690. 2. Olie, K., P. L VermuceJen and 0. Huizinger. Chemosphcre 6;4S5S (1977). 3. G. A. Eicemin, R. E. Clement and F. W, Karasek. AnaL Chem. Si; 2343
(1979). 4. Glassman, I. I. Combustion (New York; Academic Press, Inc., 1977).
5. Benton, S. W. Foundation of Chemical Kintttcs, (New York; McGraw-Hill Book Co., I960).
HOMS 221625
CHEMICAL PROCESSES S9
6. Robinson, P. J., and K. A. Holbrook. Unimolecular Reaction {New York:
John Wiley it Sons, tnc., 1972). 7. Stull, D. R., and H. Prophet "JANAF Thermochemical Tables," NSRDS
Report NBS-37, U.S. Government Printing Office (1971). 8. Cox, J. D., and G. Pilcher. Thermochemistry of Organic and Organomttahc
Compoundt (New York: Academic Press Inc., 1970). 9. Stull, D. R., E. F. Westrum, Jr and C C. Sinke. Chemical Thermodynamice
of Organic Compounds (New York: John Wiley & Sons, Inc., 1989).
10. Shaub, W. Thermo Chemika Acta. 11. Benson, S. W., and H. E. O'Neal. "Kinetics Data on Gas Phase Unimolecular
Reaction," NSRDS Report NBS*2I, U.S. Government Printing Office (1970). 12. Benson, S. W. Themiochtmieal Kinetics (New York: John Wiley A Sons, Ine., 1976).
13. Kerr, J. A., and A, F. Trot man* Dickinson. "Bond Strength of Polyatomic Molecules," in CRC Handbook of Chemistry and Physics (Cleveland, Ohio: CRC Press, Inc., 1980).
14. Tsang, W. "Comparative Rate Single Pulse Shock Tube Studies on the Thermal Stability of Polyatomie Molecules' in Shock Tubes in Chemical Technology, A. Lifshitz, Ed. (New York: Marcel Dckker, 1981), pp. 59-81,
15. O'Neal, H. ., and S. W. Benson. "Thermochemistry of Free Radicals' in Free Radicals, J. K. Kochi Ed, (New York: John Wiley and Sons, Ine.. 1973), Chapter 17.
16. Colussi, A. J., F. Zabil and S. W. Benson. Int. J. Chem. Kin. 9:161 (1977). 17. Atkinson. R., K. R. Damall, A. C. Lloyd, A. M. Winer and J. N. Pitts.
"Kinetics and Mechanisms of the Reactions of the Hydroxyl Radical with Organic Compounds in the Gas Phase" Adv. Photochem. 11:375-488 (1979). 18. Hcicklen, J. Inti J. Chem. Kin. 13:65) (1981). 19. Kerr, J. A., and M. J. Parsonage. Evaluated Kinetic Data on Gas Phase Addition Reactions (London: Buttcrworths, 1972). 20. Kerr, J. A. "Metathelical Reactions of Atoms and Molecules," in Compre hensive Chemical /fineries, Vol. 19. Selected Elementary Reactions (New York: Elsevier Nonh-HolJand, Inc., 1976), p. 39. 21. "Appendix VIII, Part 261," Federal Regtster (January 22, 1981). 22. Crumpler, E. P., E. J. Martin and G. Vogel. "Best Engineering Judgment for
Permitting Hazardous Waste Incinerations," paper presented at the ASME( EPA Hazardous Waste Incineration Conference, Williamsburg. VA, May
1961. 23. Duvall, D. S,, W, A. Rubey and J. A. Mescher. in: Treatment of Hazardous
Waste Proceedings of the Sixth Annual Research Symposium, D. Schultz, Ed., U.S. EPA Report EPA 600/9-80*011, Cincinnati, OH.
HONS 221626
CHAPTER 3
COMBUSTION CHARACTERISTICS OF CHLORINATED HYDROCARBONS
Selim M, Senkan Department of Chemical Engineering Massachusetts Institute of Technology Cambridge, Massachusetts 02139
Combustion of chlorinated hydrocarbons (CHC) is an attractive treat* mem process for ultimate disposal of chemical wastes bearing these com pounds. Destruction of CHC via combustion brings about a number of special problems, in which very little fundamental work has been done. Consequently, present CHC incineration technology involves a high degree of empiricism, and is a costly operation. Therefore, developing a better understanding of the fundamental scientific principles of CHC combustion is important for the design and operation of reliable and efficient incinerators.
Previous CHC combustion research can be divided into two major categories:
1. Research u conducted involving a number of large-scale test runt in existing eombutuon facilities sueh as rotary kilns, fluidued beds etc., mainly undar the auspices of the ll.S. Environments) Protection Agency (EPA). Except for specific operating guidelines, thess tests did not produce any fundamental data on CHC combustion.
2. The funds mental combustion characteristics of a number of CHC were studied mostly due to their flame inhibition eharaeicnstici. However, because chlonnaicd hydrocarbons are not as powerful as other halogens ted species as inhibitors, they were not itudicd thoroughly.
61 HONS 221627
ij INCINERATION AND WASTE MANAGEMENT
Additionil work under milder thermal conditions also exists in which solid or liquid catalysts were used to promote combustion. There are a number of proprietory designs and catalyst formulations for catalytic combustion of CHC.
Despite the lack of sufficient prior work in the literature, available information and recent research in our laboratories indicate a number of important features of the CHC combustion, such as low flame com bustion rat's and high soot formation propensities, when compared to non-CHC and the presence of staged combustion phenomena at atmos pheric pressure. These and related subjects will be discussed in this chapter.
In examining the fundamental combustion properties of CHC, it is important to isolate the effects related to transport phenomena, to get an accurate understanding of the chemical rates and mechanisms involved. This can be achieved by studying prentixed systems in which the fuel and the oxidant are mixed to molecular homogeneity such that diflusional problems are minimized. In catalytic combustion, additional precautions must be taken to ensure that there are no transport limitations, both within and outside the catalyst structure. Premixed, gas-phase systems will be considered in this chapter, unless otherwise noted.
GENERAL THERMODYNAMIC CONSIDERATIONS
Combustion reactions of conventional hydrocarbons, i.e,, without halogens, have been documented in many sources [1,2] and will not be repeated here. The presence of chlorine brings in a number of additional features that influence the combustion characteristics of CHC com pounds.
Thermodynamics of CHC combustion are complex because of the incomplete understanding of the chemistry involved, i.e., the intermedi ates and products of combustion are not fully known. However, one can still examine CHC combustion from a heuristic point of view and develop an insight into the overall process. If a general CHC compound is designated by C*H}Clt (where x = 1, y - 1 and z - 3 for CHClj), the overall combustion stoichiometry can be defined for y > z by;
C,H,a, (*
O, * xCOi iHCl *
H-0
(I)
For CHC compounds in which y < z, the formation of molecular chlorine must be considered as:
HONS 221628
COMBUSTION CHARACTERISTICS OF CHC (3
2-v C.HjCI, * *0, * xCOj JHCI -j-i- Cl,
(2)
In practical operations, the formation of Clj is undesirable because it is highly corrosive, and it is relatively difficult to remove from stack gases. Thus, auxiliary fuel with sufficient hydrogen content may be needed to suppress CI2 formation. The most suitable auxiliary fuel, with the highest hydrogen content, is methane, with the following overall stoichiometry for combustion:
CH 20i CO, 2HjO
(3)
Suppression of Cl] formation by auxiliary fuel can best be illustrated by examining the Deacon reaction;
H,0 * Clj * 2HC1 0.3 O,
(<)
Higher temperatures favor the equilibrium formation of HCI. and this, combined with the use of sufficient amounts of auxiliary fuel (as manifested by the formation of HjO) should minimize the formation of CI2 if the amount of excess oxygen present in the system is not high.
If methane is used as the auxiliary fuel, the overall combustion stoichiometry for the mixture will be as the following;
CiHjCl, * J CH, <7 * * ^7^) i * (x 1) CO, * iHCl * (j
HjO (5)
where R CHC-lo-methane molar ratio
The use of auxiliary fuel is frequently needed not simply to suppress chlorine formation, but also to increase the heat of combustion of the mixture for effective incinerator operation. In Figure 1 the lower heats of combustion (LHC) of a variety of CHC are shown as a function of chlorine content of the CHC compound [3]. It is extremely difficult to stabilize flames using air when the heat of combustion of a fuel mixture is less than about 4000 keal/kg. Clearly, there are incinerator configura tions, such as vortex burners, fluidized beds and catalytic units, that can sustain combustion even when lower-LHC mixtures are used. However, they frequently have other constraints, such as the unacceptably low maximum temperature limits of operation, which allows them to be suitable only under special circumstances.
Another important parameter one must introduce is the equivalenceratio (4>) of the fuel-oxidant mixture, frequently defined as the ratio of actual to stoichiometric fuel/oxygen ratios. This can then be written for Equation 5 as:
HONS 221629
44 INCINERATION AND WASTE MANAGEMENT
*
ctual O]
(6)
li pretent in the system corresponds to the exact stoichiometric oxygen requirements based on Equation 5, and 4 > 1 and 6 < 1 correspond to fuel-rich and fuel-lean systems, respectively.
The products of combustion of CHC in premixed systems principally depend on temperature, equivalence ratio of the original mixture and chemical structure of the parent CHC compound. As will be discussed later, the low combustion rates and high sooting characteristics of CHC bring in additional constraints on the design and operation of practical systems. One cannot examine combustion thermodynamics without due regard to the actual chemical kinetics and mechanisms involved; indeed, many of the pollutant emissions from incinerators can be traced to rate processes rather than thermodynamic limitations.
V
10000 - C(K(
Hitt Of CoabuitlOA tcil/kf
'A a
0 Calculated
A CkhHmauI
1000 -
O O CHCl 3
zo (0
so
CHC Chlortn# Contain, ! by Vat^t
Flfiirt 1. Effect of chlorine content on heat of combustion. HONS 221630
COMBUSTION CHARACTERISTICS OF CHC 65
In CHC combustion, pyrolysis of the parent molecules must be con sidered first, due to the relatively weak C-Cl bond. This pyrolysis frequently involves the formation of relatively stable intermediate mole cules followed by a degenerate branching step. The intermediates that form influence the product distribution as much as the original CHC molecules. Examples of such pyrolysis reactions are the following:
CG4 * C(i) 2 Cl, CHjCIj e C(|) 2HC1 CHC1, C(i) HCI Cl, C3H5CI - C,H4 HCI
(7) (I) (9) (10)
Table 1 show's the bond dissociation energies of a variety of CHC and provides a comparison with the conventional hydrocarbon systems. As can be seen, the energy required to remove a chlorine atom from a CHC is less than that for hydrogen or the scission of a C-C bond. The dechlorinated species can then undergo a variety of reactions. For example, they can recombine to form other CHC compounds, undergo further pyrolysis, oxidize or polymerize (see below). The exact scenario is quite complex, and no attempt will be made here to enumerate all the possibilities. Indeed, such an attempt will be highly speculative due to our incomplete understanding of the chemistry involved.
Tabic I. Bond Dissociation Energies of Compounds R(kraal to CHC Combustion
Bond Strength (keal/g-mol at2M*K)
Parsnt Complex
H
G
HOCHr
C,Hr CjHt-
c4h,C*Hr CH,CHj* CCIjCHjCOCNOHC*HjCOCHyCICHCIr C3HC14. CH-=CH-
104 103 i03 51 104 84 91 II 95 II 92 11 no 95 83 69 96 7J 16 82 120 97 119 60
74
101 96 94 101 91
HONS 221631
U INCINERATION AND WASTE MANAGEMENT
From a global point of view, the formation of HCI and Clj would be
expected to constitute the bulk of the chlorine-bearing species in the com bustion products. They are related to each other through the Deacon reaction discussed above (Equation 4). It is important to note, however, that in practical systems, Clj concentrations above those predicted by the Deacon equilibria have been observed [4].
Depending on the mixture equivalence and H/CI ratios, chlorine can also end up in many different compounds. For fuel-rich systems, the presence of CO will be unavoidable. The CO can then react with chlorine to form phosgene as shown below;
CO Clj = COGj
or carbonyl monochloride:
{ID
CO * O.SCli COCl
(12)
Although higher temperatures favor the presence of CO rather than COCIj or COCl, their potential production in chlorine-rich systems cannot be ruled out, Many CHC in mixtures with air have been shown 10 yield COClj readily in the presence of Fe, Cu, Zn and A1 catalysts at rela tively low temperatures [5]. Carbon tetrachloride yields COCI2 at a temperature as low as 100*C in the presence of iron, while CHClj, C2HCI), C2H4CI2, C2CI4 have given recognizable amounts of phosgene around 300*C.
Possible reactions of chlorine with carbon species at high temperatures may include:
cks) ci, . 2 ecus)
o.5C,(d * a, * ca^fi)
(is)
(M)
However, the products of Equations 13 and 14 can be converted to other species with the formation of HCl:
CCKs) HjO HCO HO ccijt*) HjO * HCOCI * HO
(15) (16)
As the equivalence ratio is increased in fuel-rich systems, soot-- polycyclic aromatic hydrocarbon (PAH)--formation is favored. As will be discussed more thoroughly in the following sections, the propensity of PAH formation increases as the chlorine content of the mixture is increased. Therefore, one must consider critically the formation of highermolecular-weight pollutants as an integral part of an incinerator design and operation. In particular, combustion of CHC has been reported to have the potential to produce chlorinated dioxins, most notably the 2,3,7.8-tetrachlorodibenzo-p-dioxin (TCDD) [6.7], The exact conditions
HONS 221632
COMBUSTION CHARACTERISTICS OF CHC 7
under which chlorinated dioxin compounds are formed are not dear. However, the general observation is that TCDD concentrations in the soil in areas with CHC combustion activities are higher than elsewhere [6], Therefore, it appears that CHC combustion processes may be a likely source for the generation of chlorinated dioxins. It is difficult to explain the formation of trace organic compounds/pollutants in combustion by thermodynamics, and their occurrence in practical devices is a manifesta tion of the rate limitations present, rather than of equilibrium conditions in these systems.
To suppress the formation of carbon-based pollutants in combustion, excess oxygen is frequently used in incinerators. However, the use of large amounts of excess oxygen will be unsuitable in CHC combustion, due to a number of reasons. First, as shown by the Deacon reaction the excess oxygen will induce more Cl, formation (Equation 4), which is unde sirable. Second, the deviation of ^ from 1 decreases the flame tempera ture and therefore the rates of combustion, resulting in potential operating difficulties. Third, the use of excess air will decrease the energy utilization efficiency. It should be remembered that as the equivalence ratio is decreased the actual increase in the heat capacity of the mixture will be much higher due to the presence of nitrogen in air,
Under fuel-lean conditions, the oxygen can undergo reactions with chlorine as:
a, o, * zoo
0, 0.50, * CIjO
o.sa, o, ao,
(IT) (IS) (19)
Additional chlorine reactions may involve the following:
co, * o, CO * CljO HjO CIO HOC! O.JH,
H,0 O, * HOC HO HO * H,0 HOa * H,
All of the reactions presented above involve stable species, some of which may or may not exist in incinerators, depending on specific operating conditions. CHC oxidation at high temperatures also brings in the reactions of radicals, which one must consider in evaluating the thermo dynamic aspects of combustion. Principal reactions that involve radicals of hydrogen and/or chlorine include:
H * HO * H, a a ho h * ci,
a, * a a
HO s H * CI
(24)
(25) (26)
C7)
HONS 221633
it incineration AND waste management
Dissociation of HC1 into its atoms is quite unlikely even under extreme temperatures; thus, the main source of Cl radicals is probably establish* ment of the equilibrium for reaction as in Equation 24. Indeed, thia criterion was used in assessing the inhibition characteristics of various halogens in flames [8],
Principal radical reactions also involving oxygen include:
Cl + Oj * CIO) a ao, 2ao O ClOj *00 + 0) o cio * a o,
2CIO a CIO, 200 = CljOi ho o, * a * HOj a HOj Ha Oj H * OOj * ao OH
(21) (2> (30) oi) (32) (33) (34) (35) (36)
Furthermore, some of the reactions that include carbon are:
a coa * co ci,
a ch4 na * ch,
H * CH3a= HQ CH)
o ch,c * CH,a * oh
OH CHja- CHjCl HjO
oh ca * ca, Hoa
(37) (3)
(39)
(40) (41) (42)
It should be remembered that the equations presented above are meant to illustrate some of the possible reactions in which chlorine and chlorine bearing compounds can participate, and they represent a fraction of the total set of reactions characterizing the overall combustion process. In principle, one may be able to incorporate some of the reactions presented above into a reaction set describing the oxidation characteristics of a wellstudied nonchlorinated fuel, such as CH, CO or H2, to develop a better understanding of the CHC combustion process.
CHC combustion may also involve the production of NO* under certain operating conditions. Catalytic combustors probably are less susceptible to NO* formation, due to milder temperatures. The oxides of nitrogen can then react with chlorine-bearing species. Examples of such reactions are:
GO NO GO NO, =
NO * Cl 2N0a *
a * NO) GONO, NOa 2N0 a,
(43) (*4) (45) (46)
MGNS 221634
COMBUSTION CHARACTERISTICS OF CHC if
a * Noa no a, Ha * NOj HNOj * CI NO ClOj * NO, CIO NO, CIO, * NO, * CJO CH,a NO, s CH,C1 HNO, Ha NO, * HNO, Cl
(47) (41) (49) (JO) (51) (32)
Getrly, the reactions presented above are far from being complete, as they were compiled to illustrate the complexity of the reaction system at hand and to provide examples.
The equilibrium constants for some of the reactions presented above are shown in Figure 2 (see Table 11 for the legend), together with some of the reactions that are common to conventional hydrocarbon combustion systems [2]. It must be remembered again that many combustion systems are not simply characterized by equilibrium considerations, and they are also influenced by the rate processes. Despite these limitations, however, thermodynamics must be considered for the effective design and reliable operation of incinerators.
GENERAL KINETIC CONSIDERATIONS
CHC possess a number of unique combustion properties that dis tinguish them from other combustion reactions. One of the most im portant of these properties is that some CHC compounds, especially those with high chlorine contents, show two-stage flame combustion at atmos pheric pressure. Although this is not an usual phenomenon, as many hydrocarbon systems possess two-stage combustion under certain condi tions, it is relatively rare to find them at atmospheric pressure. The presence of two-stage combustion in CHC systems can probably be attributed to the relatively less strong C-G bond in these compounds (see Table I). Low-temperature flames are then probably initiated by the formation of G radicals by pyrolysis, and then sustained by sets of chain reactions involving a degenerate branching step [9].
Because the C-G bond is relatively weak, it is not surprising that chlorinated compounds promote low-temperature oxidation rates of conventional hydrocarbon systems when they arc mixed together. Many CHC not only increase the preflame combustion rates of non-CHC, but they also decrease the ignition temperature of the mixture [10].
Although CHC promote oxidation rates at low temperatures, they in hibit hydrocarbon combustion at higher temperatures. Indeed, CHC compounds are better known as flame inhibitors, as they suppress
HONS 221635
7# INCINERATION AND WASTE MANAGEMENT
-io4/t
LOG
5000 2000 (500 1000 900 800 700 TEMPERATURE, DEGREES "KELVIN
600
Flfurt 2. Equilibrium constant* for reactions relevant to CHC combustion (tee Tsblt 11).
MONS 221636
COMBUSTION CHARACTERISTICS OF CHC 71
Table II. Reaction* of Imereti h* CHC CombuatiM
Carbon Reactioni [2]
1. Qt) 2. C() * a*j 3. C 0.30} * CO 4. C 0.5N, * 0.5C}N, 5. C 2H,0 * CO} * 2H, 6. C * H}0 CO H, 7. C * CO, 2CO
I. CO 0.50, CO, 9. CO H,0 * CO, * H, 10. CH4 C 2H, it. 0.3C,H4 c * H, 12. HCHO CO * H, 13. 0.5C,H, * C 0.5H, 14. 1/3 CjO, * 1/3 HjO CO 1/3 H,
Nitrogen and Oyxgen Reaction* [2]
13. O, * 1.30, 16. 0.3N, 0.30, * NO 17. NO * 0.30, NO,
II. NO 0.5 N, a N,0 19. H, * 0.30, H,0 20. 0.5N, * I.5H, > NH,
Sulfur Reaction* [2] 21. 0.5S,(t> > Sfl)
22. SO, SO OJO, 23. SO, + 3H, H,5 2H,0
24. 0.5SO, * Vi H,S - 0.5S,(i) * 2/3 HP
23. H,S HS 0.3 H, 26. CO H,S * COS * H,
Radical Reactioni with No Chlorine [2]
27. C 0.5N, * CN 21. CH CH, OJH, 29. 2N N, 30. N * O * NO 31. 20 O,
32. 2H a H, 33. 0.5H, 0, * HO, 34. OH * O * HO, 35. OH * 0.5H, * Hp
Chlorine Reaction!
36. COO, CO O, 37. COO 0JCI, CO 3*. 2HO HjO, a 2H,0 O, 39. CO* C 20, 40. C,C1, 2C O, 41. C-CU * 2C 20, 42. C:C1* * 2C * 30,
43.2c a, a 2ca 44. c a, a ca,
43. 0.30} * 0.30, CIO
46, 0.30, * 0, * CIO,
47. CO, * O, * CO Op
41. CHjO, Hp HCHO 2HO
49. O, a 20
50. HO H Cl 51. H HO a Q * H, 52. H * O, O HCt,
53. a ch4 ho * ch, 54. a ao, * 2ao 53. o ao, ao * o,
MOMS 221637
72 INCINERATION AND WASTE MANAGEMENT
combustion rates at elevated temperatures, i.e., temperatures above ~800#C. The inhibitory effects of CHC compounds are generally accepted to be due to their free radical scavenging characteristics. Scavenging is defined as a process that converts reactive radicals, such as H, OH and O, into stable molecules and/or less reactive radicals. During high-temperature combustion, many such radicals form and participate in the reaction network.
The most important chain branching reaction in combustion is:
H O, - OH 0
(S3)
Chlorinated compounds compete successfully for H radicals at moder ately high temperatures and render them less reactive, for example by reactions such as:
Cl * H -- HQ
Ha h - h, a Oj h -- Ha a CHjO H - CH, * na Ha oh - HjO * a
(54) (5J)
<W>
(57)
(31)
This results in decreased combustion rates, best manifested by the decrease in measured laminar burning velocity. As the temperature is further increased, the inhibitory effects of chlorinated compounds di minish, because now the H, OH and O radical-forming reactions with their higher activation energies can successfully compete with the scav enging reactions [11].
CHC also have a higher propensity for soot formation due, in pan, to the weak C-Cl bond strength and the free radical scavenging charac teristics of chlorine and chlorine-bearing species; this propensity seems to be directly proponional to the chlorine content of the mixture.
In the remainder of this section, chemistry and mechanism of CHC combustion, laminar burning velocity, and soot formation will be pre sented in more detail. Although these topics are highly interrelated, they will be discussed in separate sections to enhance the presentation of the important features involved in the combustion of CHC.
Chemistry and Kinetics of CHC Combustion
Although the presence of two stages in CHC combustion has been demonstrated experimentally, the actual chemistry and mechanisms involved in the overall process are poorly understood. However, there is considerable literature on two-stage combustion aspects of conventional hydrocarbons, and an insight to CHC combustion can be obtained by examining that previous work [1,12].
HONS 221638
COMBUSTION CHARACTERISTICS OF CHC 73
The two-stage combustion phenomenon is frequently discussed in the same context with "cool flames." The underlying principles are probably similar, however, the relative temperature ranges can be quite different.
The general feature of two-stage combustion is that although an explo sive reaction occurs during the first stage of combustion, it falls short of proceeding to completion. Instead, the reaction is self-quenching, and a fraction of the total available enthalpy of combustion is released. Analysis of the intermediate products in non-CHC systems showed the presence of peroxides and aldehydes. Although a long controversy existed as to the relative importance of RO:H vs RCHO as the active intermediate, it is well documented now that hydroperoxides are the autocatalytic inter mediates, and that aldehydes are the important fuel source in the inter mediate region. Under certain circumstances, the first stage terminates in complete combustion, i.e., it leads to the second stage.
On a temperature-pressure (TP) diagram for a given mixture composi tion, the existence of cool flames and two-stage combustion can best be illustrated by identifying the zones of multiple ignition temperatures at an isobar. Such a diagram is shown in Figure 3. Regions to the right of the
Tonporitur*
Fifurt 3. Combutiion phenomena aitociated wtih CHC end hydrocarbon oxidation.
HONS 221639
74 INCINERATION AND WASTE MANAGEMENT
cool flames ire regions where fist ignition mty set. Regions to the left correspond to slow reactions, which ire unimportant in combustion.
An important feature of two-stage combustion is thit although there is an ippreciable temperature increase along the first stage, the reaction rate does not appear to accelerate. In fact, the rate after the first flame is slower than just before. This behavior corresponds to what is called as the "negative" temperature dependency for the reaction. The rate of reaction, instead of increasing with temperature, decreases. This clearly indicates that self-quenching must be chemical in origin. One possible explanation to this observation is the presence of two reactions in series, with the second one having a significantly higher activation energy [1,13]. On the other hand, one can also explain the two-stage phenomenon by intro ducing a set of chain reactions with a degenerate step that is responsible for the delayed second combustion stage [1,9,13].
The combustion mechanisms suggested for CHC compounds, although they are very few, can also be categorized according to the two ap proaches described above. Hoare et al. [14], in studying the oxidation of methylene chloride at temperatures above 500* C in sutic and flow systems, discovered that the overall stoichiometry of the reaction tended
to be:
CHjCj 0.50, * CO 2HC1
(J9)
but the products also included C02, H20, C2H2CU, C,HGj, C,CU, CjHjCIj, CHClj, CCU, HCHO and Cl2, They noted the similarity of CH2C12 combustion to pyrolysis and suggested the following reaction mechanism:
CH,C1, * Cl - CHC1, * Ha
(60) [primary chain]
CHO, * CH.Clj - CHCICHC1 * HCl O
(61)
CHOCHa 0, - H,0 * CO ca, [dejeneme branching]
(62)
CHOCHa * a - c,Ha, * Ha
(63)
c,Ha, o, - :co * ho* a
(64)
cci, * cH,a, - :cHci, CH,a, * H,0 * HCHO * 2Ha
(65) (66)
Will WtSi 2CH,a, - CHCljCHO, - CHC1CC1, * HCl
[chain termination]
(67)
HONS 221640
COMBUSTION CHARACTERISTICS OF CHC 75
will ZCClj - CjCU
(61)
It was also suggested that CHCG can act as a degenerate branching agent. Clearly some of the reactions in this set, such as Equations 62 and 64, must occur in a number of steps, as it is improbable that they represent elementary reactions. Although the mechanism presented above explains some of the pathways for production of intermediate species, such as C2CU and HCHO, it fails to provide an explanation for the formation of species such as COGj and GO under fuel-lean condition!. At 533'C, the maximum reaction rate was correlated with:
- jx [CHjCIJ
<W)
A somewhat similar reaction mechanism involving simple inter mediates was postulated by Kaesche-Krucher [15] for two-stage com bustion of CH2CI3 and C2HGj. Accordingly, CH2G2 combustion involved:
CH)C1) Oj "* COj * Hj + Ctj
fim tti|t
(70)
Hj Cl2 -- 2HG
second sup
(7|)
Similarly, two-stage combustion of trichloroethylene was postulated to be;
CjHC) 20j -- HQ C02 CO CljO firii stiff
(72)
CO * CljO -- COj Clj
tccoad tuft
(73)
Obviously the reactions demonstrated in Equations 70 to 73 are far from being elementary reactions. The simple oxidation mechanisms suggested above are highly unlikely, in view of fast Hj-G2 and CO-G2 reactions. In the absence of any oxygen CH2G2 quantitatively decomposes to C and HQ as:
CHjO} - C(i) * 2HC
(74)
Equation 74 proceeds with a considerable induction period at tempera tures above 500*C( with the formation of other CHC carbon inter mediates similar to the ones discussed earlier.
Thermal decompositions of tetrachloroethane and trichloroethylene have been studied by Barton and Howlett[16]. Reaction networks similar
HONS 221641
74 incineration AND WASTE management
to the one* corresponding to CHjClj were postulated, with provisions made Tor the formation of higher CHC compounds such as:
c,h,ci a - c,hci, ho
<75)
CjHa - c,Ha,* a CjHOj * a -- CjO) hc
(76) (77>
C,CI, - C,Clj Cl
(71)
<c,aj> - (C,a,),(C*aj
(79)
Chlorine-photosensitized oxidation of trichloroethylene has been studied by Huybrechts and Meyers [17] at low temperatures and the following reaction mechanism was proposed:
CjHOj 0.30] CHOjCOCl lifhl
a,---- ia
[overall reaction]
a c,Ha, - CjHOj
CjHcu aa - c,Haj a
CjHCtt Oj' - CjHOjOj
(0)
<*)
(M> (13)
(M)
C]HCI*Oj CjHCG - CjHCUOiCjHCU
(13)
2C:Ha,Oi - CjHOOjCjHCt* * 0,
(6)
or
2C,Ha40] - 2C]HCI0 O,
C1HCI4O - C]Ha,o * a
(7)
(t)
C:HO, -- termination
(S9)
There have been a number of studies published on homogeneous gasphase oxidation of chlorethylenes in relation to the problems of atmos pheric pollution [18,19]. Most of these studies were done under mild thermal conditions and the reactions were initiated using light, mercury sensitization or ozone. The reaction mechanisms developed have essen tially been the extension of the mechanisms proposed by Huybrechts and Meyers [17] and the interested reader is referred to the general review of the subject given by Sanhueza et al. [19]. From the foregoing discussions, it is clear that CHC oxidation and pyrolysis are quite similar, and that both processes would be expected to occur simultaneously under actual incinerator operating conditions.
HOMS 221642
COMBUSTION CHARACTERISTICS OF CHC Tt
At discussed above, CHC combustion involves many reactions, in series and in parallel. Although the specific reactions present in a given system may be difficult to identify, one may break down the overall chemical event into a set of elementary chemical reactions. In recent years, the quantity and quality of experimental data on elementary reactions that are encountered in combustion have reached a point where it has become possible and reasonable to develop models to simulate actual combustor performance. Indeed, with respect to conventional hydrocarbons many compilations of such reaction sets exist [20,21], Rate constants for various elementary reactions involving chlorine are given in Table 111. These are mainly compiled from Kondratiev [21] and Baulch et al. [22]. It can be noted that the activation energies of the reactions that involve the H radical are moderately low (i.e. reactions 92 to 98), as discussed earlier with respect to the radical scavenging characteristics of chlorine-bearing compounds at moderately high temperatures.
There is also a considerable patent literature on the solid-<atalyzed combustion of gaseous CHC. The use of noble-metal catalysts, such as Pt, Pd and Ru, and oxides of metals such as Fe, Cu, Cr, V, U, A), Mo and W were reported to convert CHC compounds into combustion products in a temperature range of 20-1000 C, depending on the particular catalyst formulation used and the CHC present [23]. Although the fundamental aspects of CHC combustion are understood poorly, the existing patent literature suggests the technical feasibility of this method as an effective means for the incineration of CHC Some CHC oxidation characteristics, such as their relatively higher oxidation rates compared to conventional hydrocarbons, as discussed earlier, will probably be valid under catalytic combustion conditions; however, the presence of solid surfaces and lower temperatures must be taken into consideration.
In summary, although some previous work exists, our understanding of the chemical mechanisms and rates involved in CHC combustion is insuf ficient to make any definitive remarks. It is dear, however, that reactions involved are very complex, and to develop a realistic picture one must consider sets of branching reactions both in series and parallel to account for the processes occurring in the combustion of CHC.
Burning Velocities of CHC
The laminar flame propagation velocity, or the burning velocity (u*), is one of the most important physicochemical properties of a combustible mixture. It is the velocity at which the flame front travels relative to the unburned mixture and provides an insight into the overall rate of
HONS 221643
in c in e r a tio n a n d w aste m a n a g e m e n t
Titil* 111. R]i Comlinli Fur Huellon* IntoUIni ChlociM [k AT* ti^-E^RT) cniVntol-Mtj
Rtiellon
*ti*A
n
Tmf<riliirt
Hint*
E. CM
90 IICI M - II Cl M
12.12 0 71 1600-2100
91 0 * IICI - Oil Cl
12.14
0
67 294.720
92 II ClljCI, - IICI Cll,Cl
D.04
0
6.1 291-460
9) II Cl, - IICI * Cl
15.0 0 2.2 300-1100
94 II MCI - II, * Cl
1).* 0 45 291-1000
95 II * CIO - Oil Cl
12.1*
0.01 4.0
96 II CIO - IICI 0
12.77
0 67 1).
97 II CC1, - IICI CC1,
11.54
0.5 3.45
91 II Cl 4 M - IICI * M
17.94
-1
0
99 on iici - a 11,0
11)5
0
1 200-500
100 Cl| M - Cl Cl M
13.57 0 40.9 1550-2100
101 Cl Cl M - Cl, M
14.55 0 It 195-320
102 Cl 0, - CIO 0,
15.17
0
0.4 200-400
10) Cl CIO, - CIO CIO
13.30
0
0
291
104 0 a, - a cio
12.40
0
2.7 174-602
105 0 CTO - Cl 0,
13.70
0
0.30 200.500
106 CIO CIO -- prodttcls
111 0 2.6 295-600
107 NOC1 M -- NO Cl * M
15.11 0 )2 00-1500
101 Cl COO - CO Cl,
15.11
).) 300-600
109 0 * ClljCI - Oil * Cll,Cl
13.23
0
7.9) 353-949
no O CCI, - COCI, Cl,
10 2)
0
45 271070
III
0 Clt, CIClIjCI - 2 IICI CO Cll,
1300
0
5.5 353-47)
112 Cl * 11} - IICI II
13.9 0 55 294-1000
II) Cl Cll, - IICI Cll,
7.04 1.97 1.5 200-500
114 Cl C,ll* - IICI c,llj
14.1 0 091 349-560
115 Cl Cll,Cl - IICI ClljCI
13.5 0 ) 1 )2)-4)2
l
HONS 221644
CO M U S T ! ON CHARACTERISTICS OF CHC
116 Cl CI1,CI - Cl,Cl Cll,
140 0 2) 1 330-47)
117 Cl C1I,C1, - 1ICI * CIICI, 1)4 2*6 27)-36)
III Cl cii,n, - ci, cii,ci
14 0 21 4 J60-47)
1 tv Cl CIICI, - 1IC1 * CC1,
12.14 0
).)) 216-39)
120 Cl CCI, - Cl, CCI,
1),*) 0 200 303-42)
111 Cl C,1I,C1 - IICI CII,CICtl]
l),0) 0
1.) 303-43)
122 a c,ii,ci - iici * c,n,ci
1)51 0
1.30 273-461
12) Cl c,n,ci - iia cii,ciici
l),)5 0
1 40 303-43)
124 a c,n,ci - a, c,n,
14.) 0 21.) 303-43)
12) a c1114ci - iici c,ii,ci
1) 0 )0 6)4-740
126 Cl l',H,CI, - IICI CII,CCI,
12.*)- 0
1.9 323-423
127 a C'tll.CI, - IICI * 01,0101,
1)00 0
).4 303-456
121 Cl c,n4ci, - na cnacH^i
l)M 0
).l 123-4)2
12* Cl C,tl4CI, - Cl, C,1I4CI
14.) 0 21.) 303-436
im Cl cn,cci, - na CjiijCi,
12.40
0
)-6 )23-426
1)1
Cl cna,ciiici - iici ca^n,a
12.*)
0
).l 123-426
1)2 Cl cn^iciia, - iici citacHa, D.) 0 ),7 1)3-413
O) Cl c,n,a, - ci,c,ii,a,
14.) 0 20.6 123-426
1)4 Cl ch^ticci, - na ciioca,
12.M 0
))) 123-423
1)5 a 010,010, - HO * CjllCU
D.IO
0
) 4 323-4)6
1)6 Cl C,ll,Ct4 - IICI C,1IC14
1).* 0 ).) 123-4)6
1)7 Cl C,CI* - ci, c,a,
14.) 0 19) 160-460
1)1 C,II4CI - C,ll4 Cl
1)* C]ii,a, - c,n,ci * ci
16.* 0 236 340-460 21.3 613-7)6
3
HONS ZZ1645
M INCINERATION AND WASTE MANAGEMENT
combustion. However, despite its definitional simplicity, measuring the * burning velocity of a combustible mixture is far from being trivial. This problem must be discussed further.
Burning velocity can most easily be related to the rate of combustion reaction by considering one-dimensional systems. The theoretical ap proaches that have been used to calculate ubcan be categorized into three groups, depending on whether they consider thermal diffusion, mass diffusion or combined effects for flame propagation [24], Thermal theories of flame propagation are based on the assumption that diffusion of reactive species in the flame zone is not important in promoting ignition, which occurs mainly due to the heating of the reactant gases. This assumption simplifies mathematics considerably, and explicit ex pressions for u can be obtained by integrating a differential energy balance equation. If first- and second-order combustion rate expressions are assumed, the following expressions for the burning velocity are obtained:
, 2Ac-A T, fRT,1'1 2 * ,, F -- 1----- exp (-E/RTfJ. tor firct-ordcr reaction
P.L1
(140)
v-'^r exp [-E/RTf], for a iccond-order reaction
(14!)
where A *
' * 4. *
L* E* A*
n.
T,,T, *
thermal conductivity specific heal unbumt gat density heat of combustion activation energy rate preexponential factor initial concentration initial and flame temperature!, respectively
In equations 140 and 141, the square of the burning velocity principally haj the Arrhenius temperature dependency. This dependency clearly demonstrates the intimate relationship between the combustion rate and the burning velocity, and serves as an important reference point.
For flames involving highly mobile, reactive species, such at H, the thermal theory falls short of explaining the observed burning velocities. Therefore, diffusion of species also must be introduced into the picture. Again, the extreme case of flame propagation, in which the diffusion of species is the only source of ignition, can be treated mathematically quite well if it is assumed that thermodynamic equilibrium exists at the flame zone [25]. The burning velocity can then be given by the following expression:
HONS 221646
COMBUSTION CHARACTERISTICS OF CHC II
<U2)
Here, kj is the specific rite, which can be considered to have an Arrhenius temperature dependency, resulting in the following expression for ut'
"k1 ~ P "E/RT,1
(M3)
Equation 143 is of the form shown in Equations 140 and 141, and shows the general correlation to be expected between burning velocity and flame temperature.
There are also mathematical models that have been developed utilizing the vital concepts in both the thermal and species diffusion theories. However, although they do provide more accurate results with a smaller number of assumptions, the models are mathematically complex and fail to provide an immediate physical insight into the processes involved.
In CHC combustion, one would initially expect the thermal theory of ignition to be adequate to describe flame propagation. This is due to the radical scavenging characteristics of chlorine-bearing compounds dis cussed earlier. Because CHC flames will be deficient in radicals such as H, OH and O, one would not expect any significant diffusion of species into the preflame zone. Indeed, inhibition studies have revealed that CHC compounds broaden the precombustion zone and force the main reaction zone into a narrower region [26].
Measurement of the burning velocity can be accomplished using a variety of methods, and many excellent reviews exist on this subject [27,28]. Most notable are the methods using Bunsen cones, flames in tubes, soap bubbles, constant volume explosions and flat flame burners. Although there is still a lack of consensus as to the most appropriate technique, the Bunsen cone method with a suitable photographic system has been used most frequently, because its simple experimental setup, the rapidity of data acquisition and the reasonable quality of data it yields when compared to other, more sophisticated methods. According to this method, burning velocities are determined by dividing the volumetric flowrates of the unbumed gas mixture to the flame front areas, which are determined from the enlarged pictures of the flame zone [29].
The combustion of chlorinated hydrocarbons requires either oxygenenriched air or an auxiliary fuel to sustain stable, open flames. KaescheKrischer [30] reported the burning velocities of chlorinated methanes and trichlorethylene in an atmosphere with varying oxygen contents. The effect of oxygen content on the burning velocity is significant, due to changes in flame temperature, as shown in Equation 140. As the oxygen content in the air is increased (i.e., inert nitrogen content is decreased) the flame temperature also increases due to decreased mixture heat capacity.
HONS 221647
II INCINERATION and waste management
Fi gures 4 and 5 show how the burning velocity of CHjCl and CHjClj vary as a function of the mixture equivalence ratio, with the oxygen content of the air as the parameter. The figures show the typical inverted U shape, with the burning velocity establishing its maximum value around stoichi ometric conditions. Furthermore, they show the negative effect of chlorine content on the burning velocity. It is important to note that for atmospheric air (21% Oi), burning velocities are extremely low (less than 10 cm/sec), which may result in flame stability problems. Both CHClj and CCI4 failed to produce a stable Bunsen flame even when pure oxygen
Figure 4. Bunting velocities of CHjCl in oxygen-enriched tir [30]. HONS 221648
Burning Velocity Ub, cm/sec
COMBUSTION CHARACTERISTICS OF CHC M
Figure 5. Burning vcloatiei of CHjClj in oxygtn^nrichcd ir [30]. HONS 221649
M INCINERATION AND WASTE MANAGEMENT
was used, thus indicating burning velocities to be lower than those obtained for CHjCl and CH3G3.
The burning velocity of trichlorethylene is shown in Figure 6. Unlike CHjCl and CH3CI3, C3HC1j does not have as sharp a peak in burning velocity. In fact the equivalence ratio seems to influence ub minimally, probably due to the nonoxidative, pyrolytic decomposition nature of the first stage of its combustion.
Although the burning velocities of CHC in oxygen-enriched environ ments are extremely important, they fall short of utility in practical systems. Consequently, one must also examine CHC burning velocities in mixtures with an auxiliary fuel and air. Besides providing important practical results, extrapolation to no-auxiliary-fuel conditions can also yield information on the individual burning rates of CHC.
In this regard. Garner et al. [31] examined how chlorinated methanes and HG inhibited the burning velocities of propane/air mixtures when present in quantities less than 1%. They concluded that the order of effectiveness in reducing the burning velocity was HG < CHjCl < CH3G3 < CHGj < CCU (Figure 7). Morrison and Scheller [32] reported the amounts of various chlorinated methanes needed to reduce the burning velocity of stoichiometric n-hexane/air mixtures by 30%.
0.6
0.8
1.0
1.2
Equivalence Ratio, d
Figure t. Burning velocities of CjHCIj in o*ygen-*nriched (if [15].
HONS 221650
COMBUSTION CHARACTERISTICS OF CHC S
FIpar* 7, Inhibition of proponr-oir noma by various chlorinated compounds [31J.
They reported in order of inhibition effectiveness similar to that of Garner et al. [31],
Experiments in our laboratories with various CHC in mixture with methane and air show somewhat similar trends. As seen in Figures 8 and 9, burning velocities decrease significantly when the CHC/methane ratio is increased, as well as when the chlorine content of the CHC compound is increased for a given equivalence ratio. Furthermore, as the chlorine content of the CHC is increased, the resulting ub vs d curve flattens more, indicating the lessened influence of oxygen concentration on the com* bustion process [29].
From the examination of burning velocity data on CHC systems, it can be concluded that these systems undergo combustion relatively slowly when compared to conventional hydrocarbons. As a conseqence, com* plete combustion of CHC would require longer reaction times and/or higher operating temperatures to achieve the same degree of destruction as non-CHC. Soot Formation of CHC
Formation of carbon and/or soot In flames is of considerable practical importance. Soot formation is undesirable because its formation is often
HONS 221651
M INCINERATION AND WASTE MANAGEMENT
Flfut I. Bumin| velocities of CH)G/CH4/atr mixtures.
related to the production of toxic compounds such as PAH or chlorinated dioxins, which pose a potential threat to human health and the environ* ment. Soot formation is also undesirable because its presence indicates the conditions of incomplete oxidation and the loss of overall energy efficiency in practical combustors. Furthermore, from the esthetic view* point, soot formation is not desirable. However, under some conditions, soot formation is desirable, as carbon aids radiation from the flames thus increasing the efficiency of heat transfer in combustors.
Soot formation is a rate-determined process, and its formation is detected if rates of carbon formation are higher than the rates of carbon gasification. The presence of soot is most easily and directly observed through the presence of yellow luminosity in flames. In this regard, conventional hydrocarbons have been studied quite extensively, and a number of reviews exist in the literature discussing the many aspects of soot formation in flames generated by carbon-, hydrogen* and oxygen* bearing fuels [33,34],
Research with CHC compounds to date principally involved examina tion of conventional hydrocarbon flames doped with CHC additives, with
HONS 221652
COMBUSTION CHARACTERISTICS OF CHC 17
2S -
20 -
Sufntnf
Vtiecnv
, tm/itc
10
I-
Mtiftvlrrw Chtotfcfe/
Mttfttnt/Air.SO'C.
OJ 10 U 14 1J U
WiKtwrt taufvttenc* Rnb. 4
F1(urt *. Burninj velocilitt of CHiOj/CHj/air mixiurct.
the general observation that CHC compounds tend to promote soot formation. Street and Thomas, [35] using a Bunsen burner system, showed that the addition of Clj or CCli increases the amount of premixed air required to suppress carbon formation in benzene/air and kerosene mist/air flames. Gamer et al. [31] studied the effects of additives, such as CHjO], CHC) and CC14, on the sooting characteristics of n-heptane/ and methylcydohexane/air diffusion flames, and concluded that as the proportion of chlorine in the additive molecule is increased, so is the effectiveness of the compound in promoting the rate of soot formation. Carbon formation in premixed chlorobenzene air flames was investigated by Scully and Davies [36], who reported higher soot yields from the chlorobenzene system when compared to its nonhalogenated analog (benzene). Wright [37], using a well stirred reactor, reported the critical oxygen-to-carbon (O/C) ratios for incipient carbon formation to be 1.7, 1.75 and 1.75 for chlorobenzene, chlorotoluene and benzylchoride, respectively. In comparison, the critical 0/ C ratios were 1.75 for benzene and 1.71 for toluene.
HONS 221653
It INCINERATION AND WASTE MANAGEMENT
The tooting aspects of CHC and their influence on the behavior of conventional hydrocarbons is again related to the free radical scavenging characteristics of the chlorine and chlorine-bearing compounds. The reduction m reactive radical concentration in the preflame zone leads to two relevant events: (I) a decreased radical attack on the fuel molecules before they enter the flame zone (thus, intact fuel may not have sufficient residence lime for combustion), and (2) fuel molecules will have more time to undergo pyrolyiii. Clearly, this combination of events is con ducive to loot formation. Although the exact mechanism of facilitation of soot formation by chlorine-bearing compounds is not clear, these compounds play a dominant role in shaping the behavior of hydrocarbon flames.
Sooting limits of various chlorinated methanes and ethylenes in mixtures with methane and air are shown in Figures 10 and 11 [38], These limits are presented in terms of the overall mixture critical equivalence ratios (dj in accordance with the combustion stoichiometry shown in Equation 5.
The negative sloping trends of the data are consistent with the nonsooting aspects of methane*air mixtures (R * 0.0) and the expected sooting characteristics of the CHC. At low CHC/methane ratios, all chlorocarbons appear to induce soot at about the same equivalence ratio.
a
at
ui
3oui
u
aut
CHLOROHETHANE/METHANE MOLAR RATIO
Fl(urt 10. Soot formation Umiu of chioromethanes in methane and air.
HONS 22165*
COMBUSTION CHARACTERISTICS OF CHC I*
FIf*r* 11. Soot formation limiti of chloroethylcnei m methane >nd air.
However, is the mixture is mide proportionally more rich in CHC, the differences of individual components become more apparent. This ob served variation can probably be attributed to the expected differences in flame temperatures and chlorine contents of the various CHC compounds examined. The sooting tendencies of CHC seem to be proportional to the chlorine content of the compound. The higher the chlorine substitution in a given series, the lower the critical equivalence ratio at which soot formation is first observed.
The results are in agreement with the soot formation mechanism involving pyrolysis of the CHC compounds with rapid dechlorination first, as the C-Cl bond is relatively easy to break, followed by combina tion of the carbon residues to form soot panicles. The dechlorination phenomenon combined with the OH, 0 and H radical scavenging charac teristics of chlorine and chlorine-beanng compounds in the early stages of the flames are all related, and they result in an earlier formation of solid carbon residues in the flames. Senkan et al. discussed the limits of soot formation in CHC/methane/air [38].
Despite the lack of understanding of the exact mechanism of soot formation, it is clear that chlorine-bearing compounds promote both the
HONS 221655
* incineration and waste management
limit* and rates of carbon formation in flames. Therefore, these properties of CHC compound! muit be considered in the design and operation of incinerators.
SUMMARY
Although the fundamental combustion characteristic! of CHC are not understood sufficiently well to make definitive predictions on the chem istry, mechanism and rates of CHC oxidation, some general character istics can still be established.
Available information indicates that CHC combustion is relatively fast at low temperatures and relatively slow at moderately high temperatures when compared to conventional (nonchlormated) hydrocarbon combus tion. Therefore, higher temperatures and/or longer residence times are needed to ensure complete destruction of CHC compounds in practical combustion systems.
Limited research also indicates that potential for soot and paniculate formation in chlorinated hydrocarbon systems is again greatly enhanced when compared to that of conventional hydrocarbons. Because of this, new constraints on excess air requirements must be considered in the design and operation of reliable incinerators.
In the design of practical systems the combustion of original chlo rinated hydrocarbon compounds and their decomposition products must be considered. Some chlorinated compounds can produce intermediate species that are more stable than the parent CHC molecules, and this possibility must not be overlooked.
ACKNOWLEDGMENTS
Parts of the research presented here were sponsored by funds from the Massachusetts Institute of Technology and the U.S. Environmental Protection Agency, Grant No. R 808314010. Sections of this work were presented at the 1981 American Institute of Chemical Engineering Annual Meeting, New Orleans, Louisiana.
REFERENCES
1.Lewis, B., snd G. Von Elbe. Combustion. Flames and Explosions of Gases (New York: Academic Press, Inc., J96I).
MONS 221656
COMBUSTION CHARACTERISTICS OF CHC I
2. Vietten, W. R. Combustion and Incineration processes (New York: Marcel Dekker, Inc., 1978).
3. Sanioleri, J. J. Chem, Eng, Prog, 69<l).68 (1973). 4. Kiang, Y -H. Chem. Eng. Prog. 12:37 (1976), 5. Sjoberg, B. Svensk Kem, Tidskr, 64:63 (1952). 6. Bufflb. R R. et al. Science, 210 385 (1980). 7. A. D. Little, Inc. "Dioxin from Combustion Sources," report issued by
ASME (1981). 8. Dixon-Lewis, G., and R, J. Simpson. 16th Symposium (International) on
Combustion (Pittsburgh: The Combustion Institute, 1977), p. Mil. 9. Semenov, N, N, Chemical Kinetics and Cham Reactions, (Oxford: Oxford
University Press, 1935). 10. Salooja, K. C. ACS Advances in Chemistry Series No. 76 (Washington, DC:
American Chemical Society, 1968), p. 226. 11. Wilton, W ., J. T. O'Donovan and R. Fristrom. 12ih Symposium (Inter*
national) on Combustion (Pittsburgh: The Combustion Institute, 1969). 12. Minkhoff, G, J., and C. F. H. Tipper, Chemistry of Combustion Reactions
(London; Butterworths, 1962). 13. Benson. S. W. Prog. Energy Combust, Sd. 7:125 (1981). 14. Hoart, M. R., R. G. Nomth and G. Whittingham. Proc. Roy. Soe. Ser. A
250:187 (1959). 15. Kaesche-Krischcr, B. Combust. Flame 6:184 (1962). 16. Barton, D. H. R., and J. K. Howlcti. J. Chem, Soe. (1951), p. 2033. 17. Huybrechts, G., and L. Meyers. Trans. Faraday Soe. 62:2191 (1966). 18. Sanhueza, E,, I. C. Htsauune and J. Heicklen. Adv, Environ. SeL Teehnol.
(1977), p. 155. 19. Sanhueza, E., I. C. Hitatsune and J. Hetcklen. Chem. Rev. 76(6).801 (1976). 20. Olson, D, B., and W. C. Gardiner, Jr. J. Phys, Chem. 81(25):2514 (1977), 21. Kondratiev, V. N. "Rate Constants for Gas Phase Reactions," U.S. Depart
ment of Commerce, NBS Report COM-72-19914 (1972). 22. Baulch, D. L., ct al, J. Phis. Chem. Ref. Data 10(1) (1981). 23. U.S. Patents: 4.045,538; 4,059,677; 4,059,675; 4.059.676.4,039.623; 4.065.543. 24. Glassman, I, Combustion (New York: Academic Press, Inc., 1977). 25. Tanford, C-, and R. N, Pease. J. Chem. Phys. 15.861 (1947). 26. Wilson, W. E. 10th Symposium (International) on Combustion (Pittsburgh:
The Combustion Institute, 1965), p. 47. 27. Andrews, G, E., and D, Bradley. Combust. Flame 18:133 (1972). 28. Rallis, C. J., and A. M. Garfonh. Prog, Energy Combust, ScL 6:303 (1980). 29. Senkan, S. M., A. K. Gupta, J. M. Robinson and H. Valeiras. "Combustion
of Chlorinated Hydrocarbons," paper presented at the EPA First State-ofthe-Art Research Seminar in Environmental Engineering, Cincinnati, OH, July 22-24, 1981, 30. Kaesehe-Krischer. B. Chem.-Ing.-Tech. 35 856 (1963). 31. Garner, F. H,, R. Long, A, J. Graham and A. Badaksian. 6th Symposium (International) on Combustion, (Pittsburgh: The Combustion Institute, 1966), p.802. 32. Momson, M. E., and K. Scheller, Combust. Flame 18.3 (1972), 33. Wagner. H, 17th Symposium (lnt`l) on Combustion, (Pittsburgh: The Combustion Institute, 1979), p. 3.
HONS 22165?
92 INCINERATION AND WASTE MANAGEMENT 34. La haye, J., and G. Prado. Chemistry and Physics of Carbon, Vol 14 (New
York: Marcel Dekker, Inc., 1978). (London) 33. Street, J. C., and A. Thoma*. Fuel 34:4 (1933). 36. Scully, D. E., and R, A. Davies. Combust. Flame 9:183 (1963), 37. Wrifht, F. J. 12th Symposium (International) on Combustion (Piusburfh:
The Combustion Institute. 1969), p. 867. 38. Senkan, S. M., J. M. Robinson and A, K. Gupta. "Soot Formation Limits of
Chlorinated Hydrocarbon*Methane*Air Premixed Flames," Combust. Flame (in press).
MONS 221658
CHAPTER 4
IMPACT OF THE RESOURCE CONSERVATION AND RECOVERY ACT
ON THE DESIGN OF HAZARDOUS WASTE INCINERATORS
John N. Cark ud James J, Cudahy IT Enviroscience Knoxville, Tennessee 37923
Passage of the Resource Conservation and Recovery Act (RCRA) in 1976 ushered in a new era of hazardous waste regulation. The U.S, Environmental Protection Agency (EPA) currently estimates that 67,000 generating facilities, handling some 43 million wet metric tons of haz ardous waste (HW) will be regulated in 1981 [1]. Approximately 10-20% of this hazardous waste is being incinerated in about 850 industrial and commercial HW incinerators [2,3], Between 1981 and 1985, possibly 50-100 new industrial and commercial HW incinerators may need to be designed and installed to meet the disposal pressure caused by RCRA [2],
Subtitle C of RCRA requires "cradle-to-grave" accountability for H W materials. Wastes will be tracked and regulated from their generation point through storage, transportation, and final treatment and/or dis posal. One of the key Subtitle C sections is Section 3004, "Standards for Owners and Operators of Hazardous Waste Treatment, Storage and Disposal Facilities." This section includes standards for treatment alter natives, which include incineration, landfill, surface impoundments, land farming, chemical, physical and biological treatment, and underground injection. This chapter will discuss the impact of RCRA Section 3004 on the design of industrial and contractor HW incineration systems.
93
HONS 221659
M INCINERATION AND WASTE MANAGEMENT
SUBTITLE C HISTORY
The proposed Section 3004 incineration regulations, first published in the December 18, 1978, Federal Register [4], contained specific incinera tion technical performance and design standards. These performance and design standards mandated criteria such as combustion temperature, retention time, carbon monoxide combustion efficiency, toxic component destruction efficiency and exhaust gas removal requirements for halogens and particulates. During the allowable comment period, industry re sponded strongly to some of the proposed performance and design standards, indicating that the combined EPA and industry incineration data base used to set the standards was poor and in need of further development and documentation. Consequently, when EPA published the revised Section 3004 regulations In the May 19, 1980, Federal Register [5], the incineration performance and design standard approach had been replaced with a proposed three-phase regulatory program.
The May 19, 1980, Phase 1 standards were interim status standards (Part 265), which regulated the operation of existing HW incinerators. The general requirements for incineration in Part 265 basically involve improving existing incineration facility operating procedures. Some of the required improvements involve startup, waste analysis, monitoring and inspection. The intent of the interim status standards was to improve the operation of existing incinerators during the interim period before the existing system undergoes the RCRA trial burn permitting process required by the Phase II incineration regulations.
Phase 11 incineration standards were published in the January 23,1981, Federal Register [6]. The January 23, 1981, Part 264 incineration regula tions set forth three performance standards that must be met by new H W incinerators during a trial burn test. The three performance standards involve principal organic hazardous constituent (POHC) destruction, exhaust gas HG removal and maximum particulate emission limitation.
The Part 264 standards for regulation of HW incinerators imposed essentially identical permitting and operational requirements on both new and existing facilities. However, because of industry comments expressing concern over the costs associated with retrofitting and upgrading existing incinerators, the EPA temporarily suspended the effective date of the Part 264 regulations for existing incinerators [3]. After reexamination of the issues involved, the EPA will either lift the suspension or initiate new rulemaking for existing HW incinerators [3]. In the meantime, existing HW incinerators will be regulated by the Part 265 interim status rules [6],
The Phase II) HW incineration standards are to be based on an extensive evaluation of trial burn data from new and existing incinerators.
HONS 221660
impact of rcra on incinerator design m
Since the trial burn requirements for existing incinerators have been suspended temporarily, the schedule for the proposed Phase III HW incineration regulations has been delayed. According to EP A. most of the specific quantitative design, operation and performance requirements for the Phase 111 regulations will be issued only when adequate technical support for these standards can be established firmly. Establishing the technical support data for the Phase 111 standards could take five or more years of intense development activity.
A regulatory impact analysis (RIA) is now being compiled for the Part 264 HW incincerator regulations for existing and new HW incinerators. The draft RIA is expected to be ready for public review by April 1983 [3] and may result in changes to the Part 264 regulations.
The ultimate H W incineration rules may include two changes from the present Phase 11 regulations. These changes may incorporate risk assess* ment procedures and the use of risk assessment procedures to allow site* specific variance of 99.99% destruction removal efficiency (DRE) [6,7], The variance would allow <99.99% DRE for certain facilities and require >99.99% DRE for other facilities, based on emissions and facility location. An evaluation of the impact of the January 23, 1981, per* forma nee standards on the design and operation of new HW incineration systems is presented in the following sections.
RCRA INCINERATOR PERFORMANCE STANDARDS
The main HW incineration performance standards are listed in Section 264,343 of the January 23, 1981, regulations [6). The key points of these standards, summarized in Table 1. have had significant impact on the design of HW incinerators.
Table 1. Summary of Performance Standards from Part 264 of the RCRA Hazardous Waite Incineration Refutation* (*)
Section Stmndard/Crlterta
Requirements
264.343a POHC DRS
POHC destruction of 9$.99% by weight baaed on watte POHC feed rales and combustion fas POHC emil lion rate measured after an pollution control equipment
264j43b HO removal
99% HO removal required when incincraiinf hazardous want containins more than 0 $% chlorine
264.343c
Paniculate emission Paniculate emissions after air pollution control equipment must not be greater than 0.01 gr/dsef when corrected to 129o CO;
HONS 221661
H INCINERATION AND WASTE MANAGEMENT
Continuous measurement of the concentrations of POHC, HG and paniculates in a suck gas is currently beyond the state-of-the-art. Therefore, compliance with the performance standards given in Section 264.343 can only be measured during a trial bum by using esUblished and newly developing suck sampling techniques.
The January 23, 1981, HW incineration regulations require that a new facility perform a compliance tn'al bum before suning normal operation, to prove compliance with the performance standards and to esublish normal incinerator operating conditions [6], The trial bum requirements are listed in Part 122 of the January 23, 1981 Federal Register [6] and are summarized in Table 11, The POHC DREcriterion is the most significant of the three perfosmance standards listed.
Table It. RCR A Trial Bern Requirements [I]
Trial Bara Plan
Trial bum plan must include: Analysis of wastes (bail of combustion, viscosity, Appendix V]JI constituents) Detailed description of indnereiioo system Detailed Inal bum text tehedult Detailed trial burn test protocol (relevant lest parameter variation) Description of emission control equipment end operating conditions during trial burn tests Procedures for rapid waste shuiofT and incinerator shutdown during test burn equipment melfunction
Trial Burn Review and Approval
Possible EPA request for additional information EPA determination of:
POHC Trial bum plan is likely to achieve object)vet Trial bum will not present imminent hazard to humans
Trial Ban Tetting/Analytical Requirements
POHC and organic chlorine waste feed Exhaust gas emissions of POHC, CO), CO, HQ, particulait and hazardous combustion
by-products Quantitative analyric of scrubber water, ash residues, end other residues for POHC POHC mas* balances Calculation of POHC DRE Calculation of HQ removal efficiency Computation of paniculate emission! Identification, sources ind control of fugitive emissions Measurement of average, maximum and minimum temperatures end air feed rates Continuous measurement of CO in exhaust gas Certification by applicant that test results snd submissions were performed is per the
spproved test bum plan
HONS 221662
impact of rcra ON INCINERATOR DESIGN *7
POHC Destruction Removal Efficiency
DRE Definition
The concept and selection of POHC is an important part of ihe incineration regulations. POHC, which are to be determined during permit trial bums, are to be selected by the EPA permit writers from the RCRA Appendix Vlll constiiuents present in the wastes to be incinerated [6). Appendix Vlll is a list of about 370 organic and inorganic hazardous chemicals first published in Part 261 of the May 19, 1980, Federal Register [5]. The Appendix Vlll constituents have been defined by the EPA as substances that scientific studies have shown to have toxic, carcinogenic, mutagenic or teratogenic effects on humans or other life forms [8]. The actual number of Appendix Vlll chemicals is higher than 370, because more than 30 of the Appendix Vlll constituents are chemical groups such as isomers or salts. For example, the constituent listed as chlorinated benzenes represents all the possible isomers (monochloroben* zene through hexachlorobenzene). The most recent version of Appendix Vlll appears in the May 20, 1981, Federal Register [9].
The POHC selection process will be based on the concentration of Appendix VIII constituents in the incineration waste feed and on the degree of difficulty of incinerating the Appendix Vlll constituents. The Appendix Vlll constituents in the waste feed that have the highest concentration and are the most difficult to incinerate will be designated by the EPA permit writer as POHC. Those Appendix Vlll constituents that represent the greatest degree of difficulty of incineration (highest thermal oxidation stability) will be the ones most likely to be designated as POHC [6].
The POHC DRE standard (Section 264.343a) requires that a HW incinerator must achieve a DRE of 99.99% for each POHC designated by the EPA permit writer, although the number of Appendix Vlll con* stituents that will be designated as POHC is not specific in the regula tions. The DRE during the trial bum is determined for each POHC according to:
w..dre *
-
X 100%
(I)
where
W,, mau feed rue of a POHC in the watte itream feeding the incinerator * mass emission rate of the same POHC present in exhaust emissions before release to the atmosphere
HONS 221663
n INCINERATION AND WASTE MANAGEMENT
As can be seen from Equation 1, each DRE is based on the weight of feed rate of each POHC into the incinerator and the emission rate of each POHC in the HW incineration combustion gas measured after going through the incineration system's air pollution conctrol (APC) equip* ment. The DRE calculation does not include any POHC present in either the incinerator ash or any APC effluents such as scrubber water. The DRE calculation includes only the suck emission of the original POHC that was fed into the HW incinerator and does not consider combustion by-products or products of incomplete combustion (PIC).
The DRE is also a function of the APC system. In incineration systems equipped with wet scrubbers such as venturis, uncombusted POHC with high aqueous solubility and low vapor pressures will have high potential for being removed. With wet scrubbers or dry APC equipment (such as electrostatic precipiutors or baghouses), uncombusted POHC that are adsorbed on soot and particulate will be removed from the combustion gas along with the particulate collected by the APC equipment.
Considerations Related to 99.99% DRE
There are many complex considerations associated with the design of hazardous waste incinerators so that a DRE of 99.99% is always achieved. Many of these factors are often poorly understood by the industrial and regulatory community, and their importance therefore may be over looked. The effects of high combustion temperature and extended hightemperature residence time are generally acknowledged as important. These two important criteria, however, are only part of the design, and attention to time and temperature alone can be a critical error.
The 99.99% DRE performance standard emphasizes the need for good combustion chamber design relative to turbulent mixing of unburned POHC and hot, oxygen-nch combustion gases outside the flame en velope. The combustion reaction rate in a flame envelope is several orders of magnitude faster than the combustion reaction rate under flameless conditions. This increased reaction rate is probably due to the formation of highly reactive free radicals in the high-energy flame environment. The reaction rate under flameless conditions outside the flame envelope is slower and involves different thermal oxidation reaction mechanisms [10]. Even though most of the POHC destruction probably occurs in the Hame envelope, attainment of the final amount of destruction necessary to achieve a 99.99% DRE also depends on good turbulent mixing outside the flame envelope. Therefore, designing a HW incineration to incor porate both turbulent mixing and flame contact is important.
HOMS 221664
IMPACT OF RCRA ON INCINERATOR DESIGN 99
In addition to the considerations of turbulent mixing and flame contact, other thermal oxidation mechanisms are important. These mechanisms include atomized liquid droplet evaporation rates, particu late melting and vaporization rates, and adsorption of uncombusted chemicals on soot particles and particulate. All these rate processes produce a situation in full-scale HW incineration in which thermal oxidation reaction kinetics are not limiting, but other practical factors, such as the degree of turbulent mixing, droplet evaporation rate and soot formation, are rate-limiting [12], These factors have not been studied and evaluated extensively, but they play an important pan in the attainment of 99.99% DRE. The design of a HW incineration system for maximum flexibility with high temperature, adequate residence time, good turbulent mixing capabilities and careful consideration of each of these other factors appears to be necessary to achieve 99.99% DRE-thermal oxida tion stability for high (TOS) Appendix VIII constituents.
Thermal Oxidation Stability
TOS is a key concept of the January 23, 19S1, HW incineration regulations [6], EPA has stated that those Appendix VIII constituents that are most difficult to incinerate (highest TOS) will be the chemicals most likely to be designated as POHC [6]. Any designer of HW incinera tors must therefore have some idea of the TOS of different Appendix Vlll and other chemicals during the design process.
EPA has recommended heat of combustion as a TOS indicator [12], apparently because heat of combustion data and estimation techniques are available for all Appendix VIII constituents. In the EPA heat of combustion model, TOS is inversely proportional to the heat of combus tion. The higher the heat of combustion, the lower the TOS of the Appendix VIII constituent.
Two publications indicate that the concept of heat of combustion as a TOS indicator may not be a very good one [11,13]. For example, Tsang and Shaub point out that, according to the heat of combustion TOS indicator, acknowledged high-TOS chemicals such as benzene, polynu clear aromatics and polychlorinated biphenyls (PCB) have lower thermal oxidation stabilities than highly unstable chemicals such as nitroglycerine and trinitrotoluene (TNT) [13]. Cudahy et al. statistically correlated flameless vapor-phase thermal oxidation DRE data for 15 chemicals with various parameters such as the autoignition temperature (AIT) and the heat of combustion [12]. Table III summarizes the results of the statistical analysis. The laboratory DRE data were expressed as T99.99/2, the temperature necessary to achieve a 99.99% DRE for a particular chemical
HONS 221665
IN INCINERATION AND WASTE MANAGEMENT
Table III. RtaulU of Linear Regreealen Analytic for Correlation of T .99.99/2
X Parameter
Autoiiniuon Temperature (*C] Ionite lion Potential <eV) Heat of Ion Formation (kj/mol) Molar Heat of Combustion (J/mol) Activation Energy <U/g-mol) Heat of Combustion <J/g) Flash Point (*C) Hal of Formation 291* C (kJ/mol) Free Energy 9 291*C (kj/mol)
Y Parameter
T 99.99/2 T 99.99/2 T 99,99/2 T 99 99/2 T 99.99/2 T 99.99/2 T 99.99/2 T 99.99/2 T 99 99/2
<h) Correlation Coefficient
0.94 oso 0.74 0 62 0.42 0.J9 0.22 0 21 o.os
R>
0.11 0.64 0 55 0.3S 0.19 0.15 0.05 0.04 0006
Table IV. Approximate Order of TOS Aecordlnc to AIT for Various NomuMIliM Organic Families
Family
Basle
TOS
Polynuclear Aromatics Biphenyls Aromatic*
Aromatic Ring N Methane* Straight Chain Paraffins Straight Chain Olefins Hydrazine*
Naphthalene Biphenyl Bcnaene Pyridine Methane Ethane Ethylene Hydrazine
Higheet Lowest
at a 2-sec residence time. The T99.99/2 was calculated based on laboritory-dertved, first-order kinetic constants, assuming Arrhenius temperature dependence for the reaction rate constant.
As can be seen from Table III, AIT had a correlation coefficient (R) of 0.94, and the beat of combustion had an R of 0.39. These correlation coefficients indicate that the AIT is a far better indicator of TOS than heat of combustion in nameless combustion. However, because of the lack of T9939I2 data under flame combustion conditions, the validity of AIT as a TOS indicator for flame combustion incineration systems presently is still in question.
Assuming that the AIT is a good indicator of TOS in flame combus tion, certain useful guidelines based on AIT values can be drawn about the TOS of various chemical familities present in Appendix VIII. The approximate relative TOS, based on AIT values of eight chemical families that account for about two-thirds of the Appendix VIII constituents, are shown in Table IV [11]. The approximate impact of substitution on the TOS of these families is shown in Table V. The AIT data base is not large
HONS 221666
IMPACT Of RCRA ON INCINERATOR DESIGN )!
Table V, Impart of Group Substitution on Thermal Oxidation SlibfUty
Thermal Oxidation Stability
Group Substitution
High Medium Low
F. Cl
X
0
II Br, CN, CNO, OH. NH,. C-OH. H
XX
CHj. NO,
X
0 II CHj, C-O-C. OCH,. C.S. SO,
X
enough to define more clearly the impact on TOS of the seven groups classified as high and medium. As a general rule, except for chlorination, multiple substitution appears to lower TOS. Halogenated organics are a particularly important subgroup of Appendix VIII. About one*third of the approximately 340 organic Appendix VIII constituents contain either chlorine, fluorine or bromine. Based on AIT values, the following tentative guidelines can be drawn for the TOS of halogenated organics [II]:
1. Chlorinated eromatict such is chlorobenzene. PCB end chloromphthilenc appear to hive the hi|hc*t TOS values of any of the Appendix VIII constituents.
2. Halogen substitution seems to increase TOS in the followins order F > a > Br.
3. Helogenation does not increase the 1 OS of ell organic eompoundi. Halogenation of stmght<baia olefins, for example, may result tn t TOS decrease.
4. For aromatic compound*, TOS tppean to increase with increasing halogen substitution up to maximum halogen substitution.
Table VI summarizes the published AIT values for organic Appendix VIII constituents [14,15). AIT values were found for only about 20% of the organic Appendix VIII constituents. The lowest reported AIT values are listed for the chemicals in Table VI,
HO Removal (Section 264343b)
According to RCRA, an incinerator burning HW containing more than 0.5% chlorine must remove 99% of the HC1 from the exhaust gas [6], For HW incinerators that are fed waste profiles containing organic
HONS 221667
t INCINERATION AND WASTE MANAGEMENT
Teble VI. AlT Veluee of Appendix VIII Constituents (It]
Phenol Dichloromt thane o-Dichlorobcnzene
Chlorobenzene Diphenylemtnc Chlorofflethenc Hexachlorobutadiene
Aniline Reiorcinol Creiylie Acid Benzyl Chloride Phthalic Anhydride 1.2,4-Tnchlorobcnzene Acetophenone Crete1 2 "Chlorona phthalcne 1,2-Dichloropropone Dimethyl Phlhakatc Formic Acid Hydracymnic Acid 2-Picolinc Bromomcihane
Naphthalene Acetonitrile Acrylamide Methyl Ethyl Ketone Benzene 1,1 .UTrichlorocthanc
Nitrobenzene Toluene Pyridine Acrylonitrile Maleic Anhydride Vinyl Chloride 1,1-Dichloroethane Vinylidcnc Chloride 1,1 j-Trichloroethene
Ethykne Oxide liobotyi Alcohol Formaldehyde Methyl Methacrylate 1 ,2-Dichlorocthene Epichlorohydrin Trichloroethylene Di-n-butyl Phthalait Acetyl Chloride Ally! Alcohol Creosote
213. 662. 641. 6.1t. 634. 632 618.
613. 601. 599. 313. 394. 371.
370. 559. 331. 357. 554. 53*. 538. 33t, 537.
524. 524. 324. 515. 491. 486. 4S2. 4S2. 4S2. 481. 477.
472. 451. 451. 457
42*. 427. 424. 421. 413. 411. 410. 403. 390. 378, 336.
HONS 221668
IMPACT OF RCRA ON INCINERATOR DESIGN 103
Tibi* V], continued
Ethyieneimine Propyl Amine 1,3,3-Trichloropropane Acroiein Nitroflycenn Hydrazine Hydrogen Sulfide Nicotine Paraldehyde Benzotnehloridt Crotoniidehyde Methyl Hydrazine Dimethyl Sulfate Acetaldehyde 1,4-Diozane Phosphine Carbon Disulfide
322. 3IS, 304. 271.
270. 270. 2M>. 244. 231. 211 207. 194. its. 113. 110. 100. 90.
chlorine levels of greater than 5-10% by weight, this standard should be economically achievable using traditional equipment such as venturi scrubbers, tray towers and packed beds. The EPA background document [16] summarizes HG removal data for eight full-scale chemical waste incinerators. Seven of the eight achieved 99% or greater HO removal efficiency, and the eighth system came close [16].
The HG removal performance standard as written will be expensive and difficult to achieve for HW incinerators that are burning waste profiles m the 0.5- to 5-wt % range. Under the proposed regulation an incinerator system operating at 1832 F. 145% excess air and incinerating 0.50 wt % organic chlorine will not be required to wet-scrub HQ and will produce a combustion gas containing about 130 ppm* of HG, The same facility incinerating 0J1 wt % organic chlorine will, however, be required to wet-scrub the combustion gas to a suck level of 1.3 ppmT of HG. Typical water scrubbing systems can generally get down to a measured level of about 20 ppmv of HQ. Demonstrating removal of HG to the 1,3ppniv range will be very difficult and expensive, requiring costly alkaline scrubbing and possibly sacrificing process reliability due to potential hardness precipiution and plugging of equipment. For these small systems, an HG emissions limitation based on stack concentration rather than removal efficiency makes more sense.
For systems with higher waste organic chlorine contents, the 99% performance sundard is readily achievable. The main inpact of the HQ
MOMS 221669
im incineration and waste management
perform*nee standard on the design of HW incineration systems will be the necessary addition of packed bed or tray-type absorption systems to the APC system and the use of alkaline scrubbing solutions.
Particulate Emission Limitation (Section 264343c)
The January 23, 1981, HW incineration regulations include a particu late emissions limitation performance standard [6]. This standard states that an incinerator burning HW must not emit paniculate matter exceeding 0.08 gr/dsef when corrected to 12% carbon dioxide (CO2). Paniculate concentrations in the exhaust gas of 0.08 gr/dsef corrected to 12% COj are achievable. To be met consistently, however, careful waste characterization, feed control, flue gas preconditioning and selection of the optimal gas cleaning and mist elimination systems are required. Venturi scrubbers, for example, will require pressure drops in the range of 40-80 in. water column (w.c.) to meet the criteria. The electrical power cost for such a system operating under induced draft is quite high, however, and must be considered carefully. At a system pressure drop of 72 in. w.c. and at 70% fan motor efficiency, approximately 160 hp will be required for each 10,000 acfm to the fan.
In many cases, test burns may be desirable to develop specific air pollution design criteria, particularly if the waste profile contains organic phosphorus, metal salts and substantia! quantities of inorganic salts. The use of emerging technologies such as wet electrostatic precipitators and high-pressure fluid jets should be investigated as a means of reducing fan horsepower requirements and improving particulate removal efficiences.
In the January 23, 1981. particulate performance standard, no detail is given on how COi should be determined for particulate correction. This important area needs clarification because of the possibility of COj absorption in alkaline wet scrubber solutions before exhaust gas sampling. Since sampling of hot combustion gas for CO] is complex and hazardous, sampling after the wet scrubbing system is recommended if reliable CO? exhaust gas concentrations can be determined. An example is given below to illustrate the importance of correct CO? determinations. For accurate CO] sampling (6% CO] - correct value)
0 04 gr 1:5. 0 OS jr
---------- x -------* ----------- corrected to 12%COj
diet 69b diet
(2)
HONS 221670
impact of rcra on incinerator DESIGN 105
For inaccurate CO2 determination (5% CO2 * incorrect value)
0 04 gr 12% 0 096 f r
x* dscf J% dscf
corrected 1012% COj
(3) '
RCRA OPERATING AND MONITORING REQUIREMENTS
Tlie January 23, 1981, HW incineration regulations specify monitoring requirements that must be performed by a permitted incinerator during normal operation [6]. These requirements include areas that typically have not been monitored during waste incineration and therefore will need to be developed by industry and equipment vendors. According to Section 264.345b, during normal operation an incinerator must be operated within certain permitted limits for waste feed rate, CO exhaust gas concentration, combustion temperature and combustion air feed rate. If any of these permit limits are exceeded, the waste feed rates to the incinerator must automatically be shut off (Section 264J45e). Con* tinuous tracking or monitoring of waste feed rate, CO and combustion air feed rate represent difficult technical design problems.
Waste Feed Rate (Section 264-345b2)
A rotary kiln incineration system designed for liquid and solid waste feeds such as those shown in Table VII can operate under many different feed rate conditions. Continuous monitoring and tracking of the waste feed rates for the seven general liquid and solid waste categories shown in Table VII is very difficult and expensive [17]. Periodic analysis of these seven wtMe streams for multiple POHC or 370 Appendix VIII con stituents as implied by Section 264.341 [6] also is impractical and costprohibitive [17], EPA must clarify and simplify these waste feed rate operating requirements and make them more practical.
Table V]]. Tjpieal *n* Categoric* tor HW Incinerator
Primary combustion chamber organic liquids Secondary combustion chamber organic liquids Aqueous organic liquids Solid 1,'bulk Solids/drums or fiber packs Sludges/hulk Sludges/drums or fiber packs
HONS 221671
JM INCINERATION AND WASTE MANAGEMENT
Air Feed Rite (Section 2(4J47al)
The Januiry 23, 1981, regulation states that the incineration permit will have acceptable limits for the air Teed rate based on trial burn data. The permitted air feed rates must be monitored on a continuous basis {Section 264.347a 1) (6). This operating requirement seems to be concerned with combustion retention time. However, air feed rate is poorly defined and must be redefined in a more practical way. One reason the air feed rate regulation must be modified is that measurement in some liquid/ solid incineration systems is difficult. For example, in an induced-draft rotary* kiln incineration system, part of the combustion air enters the system through the solids feed chute and the rotary-kiln seals. This air is very difficult to measure. To alleviate this situation, air feed rate permit limits could be replaced by some retention time indicator that could be mea sured more easily and would be reasonably simple and accurate. EPA could investigate the feasibility of the following directly proportional retention lime indicators:
incinerator combustion fas flowraie, major induced or forced draft fan flowrate or motor current, and incineration intern pressure drop
Any of these techniques regulates combustion retention time more simply than permit limits on air feed rate.
Carbon Monoxide Monitoring (Section 264.347a2)
Analytical equipment does not exist for the continuous determination of specific Appendix VIII constituents in a stack gas. EPA therefore plans to monitor the organic destruction efficiency of RCRA-permuied HW incinerators by monitoring combustion temperature and CO levels con tinuously as indicators of good combustion. If the combustion tempera ture drops below permitted limits or the exhaust gas CO concentration rises above permitted levels, the HW feeds must automatically shut off.
Nondispersive infrared radiation (ND1R) is the analytical method referenced by the EPA for continuous monitoring of CO in exhaust gases. The analytical method and instruments, however, must be selected carefully ior operation under the specific waste gas conditions. Other analytical techniques, such as gas chromotography with flame ionization detection and electrochemical transducer methods, shouid be considered. The analytical techniques should be considered. The analytical techniques
HONS 221672
IMPACT OF RCRA ON INCINERATOR DESIGN 107
should be evaluated relative to the exhaust gas characteristics for the following factors:
particulate interference, water vapor interference, system durability (resistance to corrosion), maintenance requirements, and gas ample preparation requirements.
Stack Monitoring
The January 23, 19SI, regulations require continuous exhaust (stack) gas monitoring only for CO [6j. However, other factors, such as the Clean Air Act (Prevention of Significant Deterioration) and state air regulalions, may require continuous stack monitoring for other gaseous com pounds. Among likely candidates are nitrogen oxides, sulfur oxides, hydrocarbons, oxygen and CO]- Technology exists today to continuously measure these compounds in a combustion gas. However, stack sample preparation technology is often difficult and complex because of the high levels of water vapor in HW incinerator stack gases that have been wetscrubbed for acid gas and particulate removal.
REFERENCES
1. `Hazardous Waste Generation and Commercial Hazardous Waste Manage
ment Capacity; An Assessment," EPA Report SW-694. December 1980.
2. IT Entiroscience, Knoxville, TN'. Unpublished (October 1981).
3. U S. EPA Office of Solid W'aste. "Standards for Owners and Operaiors of
Hazardous Waste Treatment. Storage, and Disposal Facilities," Federal
Register 46<202):31407-31410 (1981).
4. U.S. EPA Office of Solid Waste. "Hazaroous Waste. Proposed Guidelines
and Regulations and Proposal on Identification and Listing." Federal
Register 43(243, Part ]V):58946-39028 (1978).
3. U.S. EPA. "Hazardous Waste Management System; identification of Listing
of Hazardous Waste," Federal Refisttr 43(98. Pan lli):330$-33I37 (1980).
6. U.S. EPA. "Incinerator Standards for Owners and Operators of Hazardous
Waste Management Facilities; interim Final Rule and Proposed Rule,"
Federal Register 46(13. Pan 1V); 7666-7690 (1981).
7. Crumpler, E,,and E. J. Martin. "A Proposed Vanance Procedure to Relate
Health effects to Hazardous Waste Incinerator Performance," paper pre
sented a; (he EPA Boiler Workshop, Cincinnati, OH, April 21-22, 1981.
8. U.S. EPA. "Hazardous Waste Management System: Identification and
Listing of Hazardous Waste," Federal Register
). Pan I11):33]2I (1980).
9. U.S. EPA "Hazardous Waste Management System; Corrections," Federal
Register 46(97).27473-27480 (1981).
HONS 221673
101 INCINERATION AND WASTE MANAGEMENT
10. Lee, K. C., H. J Jahnei and D C. Macauley. "Thermal Oxidation Kinetics of Selected Organic Compounds," Proceedings of 71 si Annual Meeting of the Air Pollution Control Association, Houston, TX, June 1978.
11. Cudahy, J. J , W. L. Troxler and L. Sroka. "Incineration Characteristics of RCRA Lined Wastes," U.S, EPA Contract No. 68-03*2368, Work Directive T-7021, Industrial Environmental Research Laboratory. Cincinnati, OH.
12. "Guidance Manual for Evaluating Permit Applications for the Operation of Incinerator Units," EPA Contract 68*01-6092, draft report (December 31, 1980).
13 Tvang, W, and W. Shaub. "Chemical Processes in the Incineration of Hazardous Materials," paper presented at the American Chemical Sympo sium on Detoxification of Hazardous Wastes, New York, NY, Aupust 1981.
14. Laboratory Haste Disposal Manual, (Washington, DC: Manufacturing Chemists Association, 1970).
13. "Fire Hazard Properties of Flammable Liquids, Gases and Volatile Solids," National Fire Protection Association, NFPA Report 323M (1977).
16. U.S. EPA Office of Solid Waste. "Background Document for 40 CFR Part 264, Subpart 0 and 40 CFR Part 263, Subpart 0 Incineration," (1980).
17. Novak, R. G., and J. J. Cudahy. Utter to U.S. EPA (March 23, 1981).
HONS 221674
CHAPTER 5
USING SOLIDIFICATION AS A WASTE DETOXICATION PROCESS
Robert B. Pojaselt Roy F. Weiton, Inc. Woburn. Massachusetts 0180]
For some reason, solidification has not widely been thought of as a detoxication process. Some may argue that this process simply prepares a waste for landfilling in a secure facility. However, solidification has been used successfully for waste detoxication for more than ten years. There are many feasible solidification processes. These processes are either commercially (i.e., privately owned) or generically available. They* can be utilized at the waste generation site or at a waste management facility offsite. There are even mobile solidification units available for use at uncontrolled waste sues or inactive lagoons. This versatility may account for the recent reawakening in interest for this often misunderstood technology.
The U.S. Environmental Protection Agency (EPA) defines "treatment" as:
toy method, technique, or process which is designed to change the physical, biological character or composition of any hazardous waste or to render such watu nonhaurdous, safer for transport, amenable for recovery, amenable for storage, or reduced in volume.
Solidification is not a disposal technique. Beyond the physical en.apsula* non prop:'ties that are inherent m most processes, some processes chemically bind or "fix" certain inorganic species to ik: crystalline
109
HONS 221675
II* incineration AND WASTE management
matrix. The quicklime process generates great heat, thereby disinfecting (i.e., through biological process) or even thermally oxidizing organics. Finally, asphalt processes may account for significant volume reduction. This chapter examines how the treatment process of solidification leads to deioxicanon.
DETOXICATION
When many materials are disposed of improperly, various toxic components are leached from them. These toxics are then able to find their way into surface or groundwaters. Solidification reduces the surface area of the waste, thereby dramatically reducing the teachable fraction, even if there is no fixation or other reaction that may further retard eluiriation of the toxics. Toxicity, in a strict sense, requires the toxic component to enter a pathway and reach a receptor in a sufficient amount and over a sufficient period of time to cause a toxic reaction. Solidifi cation reduces the probability of this happening, even if the material is not chemically destroyed.
EPA defines two types of hazardous waste: one that fails the characteric tests of ignitability, corrosivity, reactivity and end product (EP) toxicity; and one that appears on an EPA hazardous waste list. If one solidifies the first type of hazardous waste, and the product passes the characteristic tests that it failed as raw waste, it is no longer hazardous. Therefore, if a waste fails the EP toxicity test but after solidification it no longer fails the test, the waste has been detoxicated.
Solidification of a listed waste is a different matter. Under the present regulations, no amount of any treatment can automatically make these wastes nonhazardous. The applicant must petition the EPA under 40 CFR, Parts 260.20 through 260.22 for "delisting" of a treated waste. This delisting procedure involves the submission of a petition by certified mail to an EPA Regional Administrator. The petition must include;
). petitioner's name end address. 2 steicineni of petitioner's imcrest in the proposed tctioi,, 3. description of the proposed action; end 4 iietemem of the need end justification for ihe proposed action, including any
supporting tests, studies or other information.
The information to be supplied under point 4 above constitutes the major portion of a delisting study. The report should address the following points, as specified in Pan 260.22, to show that the waste in
HONS 221676
SOI IDtFICATION for DETOXICATION ]]|
question does not exhibit the characierisuc(s) that caused it to be listed as generically hazardous:
1 nime end address of (he labor*lory facilny performing the sampling or tests of the wittes.
2 names and Qualifications of the persons sampling and testini the wait*; 3 dates of samplmi and letting; 4 location of the feneration facility, 3 description of the process and feed materials productni the waste and an assessment
of whether such processes, operations or feed materials can or might produce a waste thai is not covered by the demonstration; 6 description of the waste and an estimate of the average and maximum monthly and annual quantities of the waste covered by the demonstration; 7 discussion (where applicable) of ihe factors delineated m 40CFR Pan 261 11(a)(3); 5 description of ihe mcthndologies and equipment used to obtain Ihe representative samples: 9 description of the sample handling and preparation techniques, including techniques used for extraction, containerization and presenatton of samples; 10 description of tests performed (including results); 11 names end model numbers of the instruments used in performing the tesu; and 12. generator's certification statement.
EPA hat reviewed a number of delisting petitions concerning solidifica tion and has published its findings and conclusions in the Federal Register. Removing from the EPA list a treated waste removes the waste at the point of treatment from the regulations regarding disposal. Because of the potential cost savings, delisting provides an incentive for the use of solidification and other detoxication technologies.
PROCESS CONTROL
Unfortunately, any treatment process is only as good as the means utilized to ensure its proper operation and maintenance (O&M). When petitioning the EPA or a potential host community, the petitioner for a potential facility site must be able to demonstrate O&M control in five critical areas:
1. waste collection end prescreening. 2. wan* preircatment, 3. addition of solidification agent. 4 mixing, end 5. handling and/or disposal
Each of these areas as they relate to the use of solidification as a detoxification process will be described briefly below.
HONS 22167?
m incineration and waste management
Watt* Collection and Prescreening
A* with any other treatment process, it is important to have the waste generator segregate waste streams that have undesirable qualities for the particular solidification agent that will be utilized. Some Portland cement processes do not readily tolerate certain types of organics, which act as retarding or accelerating agents. Because of the vast variety of different solidification processes, proper prescreening can find a suitable match between waste type and solidification agent. However, economics may then dictate the preferential use of another treatment option. Pre screening is also required as part of the ongoing effort to make certain that the process receives no surprises with respect to waste stream characteristics.
Waste Pretreatment
Some wastes can be solidifed directly, while others must be pretreated. Physical pretreatment process units required by some solidification units include thickening, dewatering, calcination and incineration. To reduce the extraction of toxics from the solidifed waste, pretreatment for cyanide destruction and chromv m reduction are usually required. Neutralization, often with another w&ste, can cut down on the amount of caustic solidification agent required. When pretreatment is required, prescreen ing is often repeated to be certain the waste is ready for solidification.
Addition of Solidification Agent
There are at least six categories for solidification agents as described in the literature. These categories are;
cement or silicaic-baicd, time-bated, thermopltatic-bued, organic polymer-bated, ceramic-batad, and
encapsulation
Each of these processes has its own requirements for addition of the solidification agent. A wide variety of different feed equipment is utilized. The amount of additive probably will be dictated by cost-effectiveness (after meeting the minimum specifications of the EPA structural integrity and EP toxicity leaching tests). Other specifications may be required, depencing on the end use of the material if it is nonhazardous and not landfilled.
HONS 221678
SO LID t F1CATI ON FOR DETOXJCATION tJJ
Mixing
Solidification is often conducted in a large batch reactor or in a smaller container. The versatility of the process also allows it to be used in situ at an abandoned hazardous waste site- The mixing required must be compatible with both the application and the solidification agent utilized. Proper mixing is essential to obtain a homogeneous end product. Random sampling will be required of all processes after solidification, as unreacted waste could spoil the testing results. Mixing must also be monitored carefully so the system does not accidentally "freeze up" with solidified material.
Handling and/or Disposal
To repeat a statement made above, solidification is not a disposal technology. If the end product is sampled and found to be "hazardous," the material must be disposed of in a secure chemical landfill. There are those who want all solidified wastes to be managed in such a facility. However, if the treated waste is nonhazardous, a landfill designed to a lesser specification may be all that is required for proper management. There are a number of productive uses of solidified wastes that provide increased cost-recovery incentives for the use of this process. Some of these demonstrated uses include: land reclamation, roadbed aggregate, artificial reefs, parking lot pavement, impermeable municipal landfill liners, and landfill cover ; nd capping material.
ONSITE VS OFFSITE TREATMENT
A controversial choice confronting every hazardous waste generator is where the wastes should be handled for treatment. Offsite regional treatment ofTers economies of scale and the possibilities for use of other wastes for neutralization and pretreatment. A potential problem is that the waste will be mixed with other wastes, and there is the question of futu.e joint liability. Wastes must also be manifested with this option, if they are hazardous.
Onsite treatment gives the generator more control over processing and handling of his own wastes. It may also remove some of the manifesting requirements. Some treatment tecnnology vendors operate exclusively in one mode or the other. Other vendors operate in either mode, to suit the needs of u customer. Ltgal and economic factors must be weighed carefully by the waste generator before deciding w-hich route to take.
HOMS 221679
114 INCINERATION AND WASTE MANAGEMENT
In the area of abandoned site cleanup, the same controversy takes the form of containment vs removal. A variety of solidification processes have been demonstrated for direct in situ containment. Other processes require removal and processing through a mobile unit before onsite recontainment. Some processes have end products that never set hard but remain friable to permit future removal to an alternative site. This remarkable versatility has recently led to the placement of solidification on many of the remedial action priority lists.
PROBLEMS SITING SOLIDIFICATION FACILITIES
Despite the proven detoxication of certain wastes and the remarkable versatility of this category of processes for waste treatment, the public has been unwilling in many cases to accept disposal of the product other than in a secure chemical landfill. Numerous vendor claims have gone unheeded. The public repeatedly asks the questions:
What will b released to the environment when the solidified product u not pieced in a fully contained landfill?
How much of each toxic component wtl! he releaied per unit maw? What will happen lo the mate and the rate of leachtna over time?
It is easy to become confused over the leaching data submitted to regulatory officials by many vendors. Over time, a variety of different testing methods have been used. There is no set pattern or even mention of the ratio of waste additive. Finally, the end product is not made to a consistent physical constant. How is one to compare the data or determine whether it is suitable for the planned management scenario? The EPA EP toxicity test settles the problem with variable teMinc protocols, but there is little agreement as to its representativeness or precision. The American Society for Testing and Materials (ASTM) has established a subcommittee of their D34 Waste Disposal Committee to look into these questions.
Some progress has been made by - STM to examine the leaching test and the physical constants that will be necessary to provide answers to the first two public questions. Howev:-, this process is slow and not necessarily directed at providing siting assistance. Someone other than vendors needs to address these questions soon; unfortunately there appears to be no attempt in the United States to provide such an answer.
The public has often been told that th treated waste is like cement. The layperson is used to seeing cement crack on roads and bridges and will strongly doubt vendor claims concerning the durability of the end
HONS 221680
solidification for detoxication Its
product over time when properly managed, Accelerated environmental testing is perhaps the most controversial aspect of testing solidifiedproduct durability. Most environmental tests, which are designed to be representative of en\ ironmenial conditions, are slow to generate useful data, and the testing process cannot be accelerated. However, just as the aerospace industry tested the long-term lifespan of critical components with accelerated techniques, a similar approach must be applied to solidified wastes. Some groundwork for this testing has been laid in Europe, but little is presently being done in the United States. U.S, vendors must overcome their reluctance and devise these tests, have them approved by an independent group, and submit standard samples for independent accelerated testing to avoid costly secure landfilling of '`nonhazardous** products.
CONCLUSIONS
Solidification has only been used for waste treatment for the past 10 yean. Encouragement is needed to bring the technology to the point where the public's questions can be answered with credibility. A quote, which appeared in the Federal Register (October 8. 1980), sets the tone for this movement:
Hazardous waste management is a new and developing field The relatively reeent concern with the dangers presented by the disposal of haurdous waste has spawned new efforts in the scientific and engineering community 10 develop new technologies that are capable of recycling, treating and safely disposing of these materials. EPA wants to encourage innovation in haz ardous waste management. In devising regulations, therefore, n is important to atoid rigid approaches that stifle the development of new technologies.
Hopefully, stite and local regulators will endorse this excellent advice in the development and application of their hazardous waste management programs. However, they will require independent data on the process proposed for each of the waste types or mixtures handled by each facility. A detailed O&M manual must be submitted before plant operation to serve as an independent chi :k of operations by the regulators entrusted in monitoring the facility. A concerted effort must be made now to move in this direction before the acve/se publicity of multiple siting failures makes credible generation of the necessary data a fruitless exercise. As described above, solidification is a versatile process, capable of detoxifying hazaroous wastes. The hazardous-waste manager must give the process every consideration when selecting a treatment sequence for a waste stream.
HONS 221681
SECTION 2 POLYCHLORINATED BIPHENYLS:
TREATMENT, RECOVERY AND DESTRUCTION
HONS 221682
CHAPTER 6
SUMMARY OF POLYCHLORINATED BIPHENYL TREATMENT ALTERNATIVES
Jur|en H. Exner IT Envirosctence Knoxville, Tennessee 37922
Technical progress on important problems continues rapidly during the time that a book is prepared. Consequently, this brief chapter intends to summarize the available polychlorinated biphenyl (PCB) destruction methods as of April 1982. This update, based on telephone surveys and company responses, is not necessarily complete.
Commercial incineration o: PCB is being carried out by Ensco in El Dorado, Arkansas, which is in the process of tripling its capacity, and by Rollins Environmental Services, in Deer Park, Texas. In December 1981 Chemical Waste Management carried out a test burn on its incineration ship, the Vulcanus, in the Gulf of Mexico. The analytical measurements from this test have not been published, and EPA approval has not been granted. Rockwell now offers for sale its molten-salt incinerator, which operates at about 700'Cand destroys PCB, Various tests on destroying PCB in cement kilns are examining the emissions of principal organic compounds. Test runs with 1600 g PCB in the plasma torch have verified a minimum of 99.9999% destruction. No dioxins were found in the offgases from this test, and a demonstration unit is being planned.
Decontamination of PCB-contaminated transformer fluids continues as an active area of commercial interest. Acurex and SunOhio have gained EPA approval in several EPA regions for detoxicating trans former fluids and expect nationwide approval within the year. Several mobile treatmen' plants are available to treat at the waste site fluics
119
HONS 221683
120 PCS TREATMENT, RECOVERY AND DESTRUCTION
containing 100-1000 ppm of PCB. The organometal processes can convert the transformer fluid to a useful fuel (Acurex) or a reusable transformer fluid (SunOhio).
The Franklin Institute process (NaPEG), which consists of nucleophilic displacement of chlorine by a superoxide radical anion at elevated temperatures, has been tested in a pilot plant at a Philadelphia utility. Much of the current effort is being directed toward chemical treatment of PCB-contaminatcd soil by spraying the reagent on the soil. The results and environmental consequences are unclear at this time. Microbial degradation of PCB-contaminated soils is being pursued by several investigators.
Brunnelle, of General Electric, reported on a simple, phase transfercatalyzed process for destroying PCB. PCB solutions can be treated with small amounts of the methyl ether of polyethylene glycol in the presence of potassium hydroxide. The substitution products are formed within one hour at 60*C, and a continuous, pilot-plant unit operatingat 100DCand a residence time of 15 min has verified the laboratory data. The substitution products, not strictly PCB by the legal definition, may be biodegradable.
It appears, then, that three years after PCB regulations took effect, the technology is available, finally, to carry out the intent of the regulations. Also, this area of work demonstrates clearly that many different ap proaches can be taken to solving pollution problems.
HONS 221684
CHAPTER 7
FEDERAL POLYCHLORINATED BIPHENYL REGULATIONS
Margaret Valla and Glenn Kuntx
U.S. Environmental Protection Agency Office of Pesticide* and Toxic Substances Washington, DC 20460
Since the mid-1960s, when polychlorinated biphenyls (PCB) were first found to pose a threat to wildlife, the chemicals have been found widely distributed in low concentrations throughout the United States, From the late 1960s until the early 1970s, the federal government approach to the PCB problem was fragmented. The U.S, Department of the Interior Bureau of Mines (BOM), responsible for water pollution, and the Department of Health, Education and Welfare (HEW), responsible for human health, undertook some PCB research, but no programs addressing the basic problems were initiated. In 1969 the Council on Environmental Quality (CQ) was formed; and in 1970, the U.S, En\ironmental Protection Agency (EPA). Both began work on the PCB problem. CEQ was the catalyst in the formation of a federal interagency task force to coordinate the federal PCB effort. In May 1972 the task force issuea a report concluding that PCB contamination was ubiquitous and represented an unqualified but undisputable hazard, and that the use of PCB should be restricted to essential application* that involve minimal oirect human exposure [1],
Once this report was issued, programs aimed at correcting the PCB problem >ere begun. In 1971 Monsanto, the sole domestic commercial producer of PCB, voluntarily restricted sales of PCB to "closed-system uses," thereby limiting sales to manufacturers of transformers and
121
HONS 221685
ill TCB TREATMENT. RECOVERY AND DESTRt CTION
capacitors [2]. Monsanto also introduced what it felt was a less toxic PCB mixture, Aroclor 1016. The EPA recommended raising water quality standards to reduce PCB levels to less than 0.01 ppb. In February 1973 the Organization for European Community Development (OECD) issued a directive that recommended limiting the worldwide use of PCB. EPA designated PCB as toxic substances and set a national effluent standard pursuant to Section 307(a) of the Federal Water Pollution Control Act Amendments of 1972 (PL 92-500). In 1973 the Food and Drug Administration (FDA) published regulations limiting the use of PCB in food and feed facilities and establishing temporary tolerances for PCB levels in many food and feed items [3], In February 1977 EPA banned PCB discharges into waterways by capacitor and transformer manu facturers, and finally in 1976 the Toxic Substances Control Act (TSCA) (PL 94-469) was passed by Congress, requiring regulation of PCB.
EPA REGULATION OF PCB UNDER TSCA
TSCA Requirements
TSCA is a law to regulate commerce and protect human health and the environment by requiring testing and necessary-use restrictions on certain chemical substances. TSCA designates one class of chemicals in par ticular for regulation. This ciass of chvrnicals is PCB.
Section 6(e) of TSCA specifically requires EPA to regulate the manu facture (including importation), processing, distribution in commerce, use, dispose anc labeling of materials containing PCB. These mandates were implemented in a phased manner, with the marking and disposal rules to be promulgated first. Accordingly, in February 1978 EPA regulated the disposal and marking of PCB (40 CFR Section 761, Federal Register 43:7150), This rule required the marking of many PCB items still in service, and set up a system for the proper disposal of PCB. On May 31, 1979, EPA instituted a ban on the manufacture, processing, distribu tion in commerce and use of PCB (Federal Register 44:31514).
There are four "exceptions" to the bans instituted on May31, 1979. Tne first two are very broad; the remaining two apply only to specific situations. First, TSCA applies, b> statute, onI> to those uses of PCB that are not considered "totally enclosed." EPA, in the May 31, 1979, regulation, considered the following uses "totally enclosed": (1) use (except servicing) of intact, nonleaking PCB transformers and PCBcontaminated transformers; (2) use (except serMctng) of intact, non-
HONS 221686
FEDERAL REGULATIONS 123
leaking PCB capacitors. Second, EPA set a standard of 50 ppm PCB concentration, below which most PCB are not regulated. Third, TSCA provided for EPA to grant authorizations for nontotally enclosed uses that present little or no risk to human health or the environment. Among the authorizations granted are: (1) servicing of transformers, electro magnets and mining equipment; (2) use of PCB in heat transfer systems, hydraulic systems and railroad transformers; (3) use as a mounting mcd am in microscopy; and (4) use in small quantities for research and development. Finally, TSCA provided for EPA to grant exemptions to certain manufacturers, processors and distributors in commerce of PCB. To be granted an exemption, two broad criteria set by Congress must be met:
1. An unreasonable risk of injur) lo health or the environment would not result. 2, Good faith efforts have been made to develop a chemical substance ihat does not
present an unreasonable risk of injury to health or the environment and that may be substituted for PCB.
Activities Since Promulgation
Exemptions
More than 400 petitions for exemptions from the prohibitions of TSCA Section 6(e)(3)(A) have been filed. Approximately 40 of these seek exemptions for the manufacture of PCB at concentrations greater than 50 ppm; nearly all of these involve processes where PCB are produced as a bj -product in the manufacture of other materials. The remaining exemp tion petitions are for processing or distribution in commerce of PCB. In the case of manufacturing exemption petitions filed for activities that were ongoing as of January 1, 1979, and processing and distribution petitions filed for activities which were ongoing as of July 1, 1979, the activities for which exemptions are sought may be continued until EPA rules on the petitions. For petitions submitted after the filing deadlines, EPA will decide on a case-bv-case basis whether or not to accept them for consideration. The late petitioner must show go.'d cause as to why the petition was submitted after the filing deadline. Of those petitions accepted, only those activities that EPA determines were underway before the dates the bans went into effect will be allowed to continue until EPA rules on ihe pending petitions. Therefore, persons who wish to begin a PCB manufacturing, processing or distribution in commerce activity that was not underway at the time the bans went into effect may not initiate the activity until EPA rules on the exemption request [4],
HQNS 221687
124 PCB TREATMENT, RECO' ERY AND DESTRL'CTION
Open Border Policy
The Ban Rule also established an Open Border Policy, which permitted import and export of PCB wastes for purposes of disposal for a period of one year. On May 1, 19S0, EPA announced that it was ending the Open Border Policy and closing all U.S. borders to shipments of PCB wastes. This decision was made because it had become apparent that few other nations were actively seeking to develop adequate disposal facilities of their own. EPA announced that it would reopen U.S. borders to ship* ments of wastes to and from any nation that entered into a bilateral agreement with the United States on standards for disposal of PCB. Such an agreement is presently being discussed with Canada. No other nation has sought an agreement.
Exports of PCB for use in other nations are permitted only if the activity was ongoing as of July 1, 1979. a petition for a distribution exemption is on file and a proper TSCA Section 12(B) export notice is submitted. If the activity was not ongoing as of July 1, 1979, an exporter must obtain an exemption from EPA before he may initiate his export.
Food and Feed Amendment
On May 9, 1980, EPA proposed to amend the Ban Rule to prohibit the use of PCB items (including PCB large high- and low-voltage capacitors, PCB transformers. PCB-contaminated transformers, PCB heat transfer systems, and PCB hydraulic systems) in facilities manufacturing, processing, or storing fertilizers or agricultural pesticides. EPA issued this proposed rule under the authority of Section 6{a)C-) of TSCA. FDA and the U.S. Department of Agriculture (USDA) published similar proposals, with each agency's proposal covering its area of legal rcponsibihty in orcer to cover the entire food, feed and agricultural chemical industry.
On May 6, 1981, EPA published a federal Register notice placing the proposal in abeyance. This decision was made :n par. because of the October 30, 1980, decision of the U.S. Court of Appeals for the DC Circuit, which is discussed later in this chapter.
ENVIRONMENTAL DEFENSE FUND CHALLENGE
Shorth after the final PCB Ban Rule was published in the Federal Regtsu the Environmental Defense Fund (EDF) challenged the validity
HONS 221688
FEDERAL REGULATIONS 115
of the Ban Rule in a petition for review to the U.S. Court of Appeals for the DC Circuit. EDFsought review of the Final Ban Rule on three points; (1) EDF challenged the determination by EPA that certain commercial uses of PCB are "totally enclosed," a designation that exempts those uses from regulation under TSCA; (2) EDF claimed that the EPA acted contrary to law when it limited the applicability of the regulation to materials containing PCB concentrations greater than 50 ppm; and (3) EDF challenged the decision by EPA to authorize the continued use of 11 nontotally enclosed uses of PCB.
In its October 30, 1980, decision, the Court of Appeals found no substantial evidence in the record to support EPA's classification of electrical transformers, capacitors and electromagnets as "totally en closed" uses, or to support EPA's establishment of the cutoff under which only materials containing 50 ppm or more PCB are regulated. The Court of Appeals therefore remanded these portions of the regulations to EPA for further proceedings. However, the Court of Appeals upheld EPA's authorizations of the 11 nontotally enclosed uses of PCB.
Because invalidation of these parts of the Ban rule by the Court of Appeals would have brought into full effect absolute prohibitions against manufacture, distribution in commerce, processing and use, EPA and other parties to the litigation requested that the Court of Appeals stay its mandate until new regulations could be promulgated. In two orders, issued on February 12 and April 13, 1981, the Court of Appeals granted that request, subject to certain conditions.
Totally Enclosed Issues
The February'order dealt with the issue of totally enclosed uses of PCB. The Court of Appeals stayed the effectiveness of its judgment that that portion of the regulations is invalid, subject to several conditions. First, the stay is for a period of 18 months and applies only to those who comply with the prescribed interim inspection and maintenance procedures known as the Interim Measures Program. Second, the Edison Electric Institute (EEI) is to conduct a study to provide EPA with information it will need for further rulemaking regarding uses of PCB in electrical equipment. Third, EPA must announce us new rulemaking in an Advance Notice of Proposed rulemaking (ANPR) and must promulgate a ".nal rule within six months of receipt of the EEI study. (The ANPR was published March 10, 1961 ) Finally, the parties must make a progress report to the court on October 1, 1981.
HONS 221689
lit PCB TREATMEM, RECOtEm AND DESTRl CTION
The 50-ppm Issue
The court's April order dealt with the 50-ppm issue, that part of the court's decision that invalidated the 50-ppm regulatory cutoff. The court stayed its mandate with respect to this portion of its decision for 18 months and ordered PA to undertake two parallel activities during the period of the stay.
The first activity applies to chemical manufacturing processes that generate PCB, but release no PCB. li also includes chemical manufac turing processes that release PCB only as constituents of wastes that are mcinceratcd or disposed of in EPA-approved landfills, or held for such disposal. On May 20, 1981, EPA published an ANPR relating to the possible exclusion of manufacture of PCB in these processes from the prohibitions of TSCA Section 6{eX3XA). EPA must promulgate a final rule with respect to this potential exclusion within the 18-month period of the stay or advise the Court of Appeals of its reasons for not promul gating a final rule along with plans and a schedule for any further action.
The second activity applies to manufacturing, processing, distribution in commerce and use of PCB in concentrations less than 50 ppm (other than the creation of PCB in those processes described above). EPA also published an ANPR regarding this activity on May 20, 1981. By March 13, 1982, EPA must advise the court of its plans for further action and its schedule for such action.
ENFORCEMENT
When the first PCB rule, covering marking and disposal, became effective in April 1978, EPA began anact:ve PCB compliance monitoring program under the direction of the Pe, licides and Toxic Substances Enforcement Division. The program was expanded when the PCB Ban Rule, which incorporated provisions of the marking and disposal rule, became effective in July 1979.
Since April 1978 more than 2000 PCB compliance monitoring inspec tions have been conducted. EPA's limited resources for inspections have been augmented by the use of contractors to perform some of those activities. lost of the cases have involved violations of marking, storage and disposal requirements. In many instances, EPA's activities required cleanup of spilled PCB material in addition to the payment of civil penalties. A number of hazardous waste cases also have involved PCB: in those instances, joint injunctions have been sought under TSCA and other EPA statutes.
HONS 221690
FEDERAL REGULATIONS 127
TSCA is a relatively new statute, and the PCB rule was the first major regulatory program established under its authority. The PCB rule was also the first major field enforcement effort, and what has been learned from this effort has helped shape all subsequent TSCA enforcement programs.
The final PCB enforcement strategy is to minimize the release of PCB into the environment, The release of PCB can occur in two ways: (1) improper disposal of PCB items and liquids when they are taken out of service; and (2) uncontrolled discharge caused by leaks and spills from inservice, stored or transported items.
In the enforcement strategy, compliance monitoring inspections are allocated among the 11 economic sectors and industries that control the vast majority of PCB now in use. The sectors identified in the strategy are: utilities; chemicals; metals; papers and lumber; mining; food; stone, clay and gas; textiles; automobiles; railroads; and commercial buildings. Inspection allocations were based on a number of considerations, in* eluding forecasts of expected retirement or rebuilding of PCB equipment, industry structure characteristics, degree of awareness of PCB require* ments by industry members, and cost of compliance.
The emphasis in the inspections is on reviewing required PCB storage and disposal records to ensure proper ultimate disposal and on examining the condition and location of PCB equipment to detect any evidence of uncontrolled discharge. The penalties assessed against facilities found in violation arc related directly to the degree of hazard poseo, and com* pames may also be required to clean (in some instances at great cost) areas contaminated with PCB.
A strategy for enforcing the Interim Measures Program is in draft form. That strategy augments ihk. overall PCB strategy by adcing checks for compliance with the new program while conducting regular PCB inspections. A more intensive monitoring effort is directed at utilities and food and feed facilities through a review of randomly selected records required by the Interim Measures Program.
DISPOSAL
Incinerators and Boiler*
Tne key to success for EPA'r program of regulatory control of PCB is the availability of adequate disposal facilities. Many of EPA's efforts have been directed toward approval of incinerators and encouraging verifica
MONS 221691
121 PC TREATMENT, RECO\ERY AND DESTRUCTION
tion bums in high-efficiency boilers. The evaluition of data from test burns in incinerators and boilers is handled by the ten regional EPA offices. Public opposition to PCB incineration and the question of toxic by-product formation have caused regional administrators to proceed very cautiously with approval of incinerators and boilers.
In January 1981 EPA approved the first two commercial incinerators: one in Deer Park, Texas, owned by Rollins Environmental Services, and the omer in El Dorado, Arkansas, owned by the Energy Systems Co, (ENSCO). EPA has a very thorough plan to monitor operations at these two facilities.
EPA anticipates the testing and approval of the incinerator ship Vulcanus. The major steps in the approval are completion and acceptance of an environmental impact statement evaluating the impact of the incinerator on the ecology of the area of the ocean where the burning will occur, and locating suitable staging and transfer facilities ashore. Should this incinerator be approved for use in the United States, a major portion of the high-concentration liquid PCB that are in storage could be incinerated in one or two trips.
EPA has provided for the disposal of low concentration (50-500 ppm) liquid PCB waste. This waste is usually mineral oil removed from electrical transformers. It can be burned in high-efficiency boilers meeting certain technical criteria. These boilers operate with very good combus tion characteristics and have been shown in repeated tests to achieve very high destruction efficiencies for PCB without emitting toxic combustion by-products. Seven boilers in the United Stales have disposed of con taminated mineral oil.
Alternative Disposal Techniques
In promulgating the disposal regulations, EPA allowed approval to be granted for alternative methods that are equivalent to incineration. The alternative method must achieve a level of performance equhalent to incineration or destruction in a high-efficiency boiler, and a written request for approval must be submitted. Before approval is granted, the applicant must show that the method of destroying PCB will noi present an unreasonable risk of injur)' to health or the environment. One such alternative method has been approved.
Mary researchers and enteprensurs have sought solutions to the problem of PCB disposal using ^ wide range of techniques, including chemical destruction, catalytic dccompof n. n and a variety of thermal destruction methods other than convent.anal incinceration.
To date only one company has built and tested a full scale commercial
HONS 221692
federal recilaTIOns i:
unit using new technology. SunOhio, based in Canton, Ohio, has constructed a mobile PCB chemical destruction unit (PCBX) and demon strated the capabilities of their system in a test conducted for EPA officials. Treatment of PCB-contammated mineral oil reduced the PCB concentration to a nondetectable level. Due 10 the mobility of the PCBX system, SunOhto is seeking the approval of all ten regional adminisiraiors so they can offer their disposal services nationwide. At this time SunOIno has received approvals 10 dispose of mineral oil contaminated with PCB in Regions I, IV and VU.
The PCBX disposal system has some interesting features. It does not produce emissions to air or discharges to water. Ii is portable, allowing the PCB to be treated onsue, thereby eliminating extra handling or transportation of the wastes. Finally, because PCBX is mobile, it should minimize opposition from local communities--opposition that fixed-site facilities have often encountered. Because PCBX presently is approved only for low-concentration mineral oil, it is not the answer to all aspects of the PCB disposal problem, but it does illustrate the potential that exists in the are* of emerging technology.
Landfilling of Capacitors
EPA recognized in the Ban Rule that the best method for disposal of large PCB capacitors (those containing more than 3 lb PCB) is incinera tion. However, no incinerators were available at the time the Ban rule was promulgated. Anticipating that an incinerator would be approved by January 1, 1960, EPA authorized landfilling of capacitors until that date. However, as no commercial incinerators were approved by January' 1, 1980, EPA extended the authorization of landfilling until March 1, 198i. The extension included a provision that the authorization subsequently could be extended at the discretion of the Assistant Administrator for iesticides and Toxic Substances if inadequate disposal facilities were available. The first incinerator capable of shredding capacitors was approved March 1981. A request by a group of electric utilities for a further extension of landfilling grace period was denied on July 28, 1981.
ADDITIONAL INFORMATION
The EPA has an Office of Industry Assistance which distributes publications and answers Questions to help people understand the Toxic Substances Regulations. They may be reached by calling the toll-free number 800-424-9065 during Washington business hours, or the local
umber, 554-1404.
MONS 221693
130 rCB TREATMENT, RECOVERY AND DESTRUCTION REFERENCES 1, "PCBj and the Environment," Inierdepanmental Talk Foree on PCBi, COM
72,104)9, U.S. Goicrnment Priniinf Office (1972), 2, "PCBi in the United States--Industrial Use and Environmental Distribution,"
U.S. EPA Criteria and Standards, EPA-560/6-76-003, 3. U.S. Code of Federal Regulations, Vol. 21, Sections 3.93, 122.10. 4. Federal Register, 45, p, 14247, Mareh S, 1980,
HONS ZZ169*
CHAPTER 8
TREATMENT AND DESTRUCTION OF POLYCHLORINATED BIPHENYLS AND
POLYCHLORINATED BIPHENYLCONTAMINATED MATERIALS
Leo Wcltxnua
Acurex Wane Technologic! Corporation Cincinnati, Ohio 45230
Polychlorinated biphenyls (PCB) were among the earliest classes of compounds to be identified as hazardous and to be banned by law. As such, they have become in many people's minds the epitome of "hazard* ous waste." This has made them difficult to control and manage safely. Because of ills uncertainty and fear generated ?y the present attitude toward PCB, there is a shortage of facilities available for their legal disposal or destruction. This chapter evaluates the legal, technical and regulatory status of PCB and their control. It evaluates the various technologies available for their destruction from viewpoints of efficacy and potential for solution of these problems.
PCB REGULATIONS
PCB were first introduced by the Monsanto Company in 1929. Because of their thermal, biological and chemical stability, and high dielectric constant, this group of chemicals achieved widespread use. There are 209 different chlorinated biphenyls, referred to collectively as PCB. PCB were used as dielectric fluids in capacitors and transformers, as heat transfer
131 HONS 221695
n: PCB TREATMLM. KECON ERt AND DESTHt CT1UN
fluids, nd as hydraulic fluids. Between 1930 and 1975, 1.253 billion pounds of PCB fluids were sold in the United Stales. Of ihis amount, 77% (965 million lb) was used for electrical equipment, largely by the electric utility industry.
In 1976 the Toxic Substances Control Act (TSCA), PL 94-469, estab lished a framework for regulating hazardous chemicals. PCB were specifically identified for regulation by TSCA. In the May 31, 1979, Federal Register [1], the U.S, Environmental Protection Agency (EPA) promulgated rules for "PCB Manufacturing, Processing, Distribution in Commerce and Use." These rules prohibited the manufacture of PCB and their use in almost ail nonenclosed applications.
The regulations created a unique situation, wherein large quantities of relatively pure materials require safe disposal. In addition, very stnngent rules for storage, shipping and disposal were set. For the purposes of this chapter, PCB wastes can be broken down into the following categories;
PCB foDdf consul largrly of shredded capaciiori, drained transformers and other PCB-coniamutated solid materials. These may be landfilled at present,
PCB liquids encompass liquids contaminated with PCB at a concentration of MO ppm or greater. The onlx legal method of disposal is destruction in high^fficiency incinerators or cement kilns.
PCB-contaminated liquids are oils containing 50-500 ppm PCB They legally ma> be burned in high<fTicienc> boilers or be landfilled.
As can be seen, the PCB regulations permit PCB and PCB materials 10 be landfilled or burned only in special incinerators, cement kilns or boilers. They also allow the Regional Administrator to approve other alternative technologies to be used if he finds that they do not "present an unreasonable risk of injury to health or the environment" and if "its level of performance is equivalent to Annex 1 incinerators or high efficiency boilers.' This is somewhat difficult to interpret, as it does noi define what specific criteria the alternative technologies must meet. This chapter will discuss several specific destruction methods.
DESTRUCTION TECHNOLOGIES
There are many methods available for the destruction of PCB. Land disposal, which is basically a confinement rather than a destruction procedure, is not discussed here. Treatment procedures can be split into two generic groups: combustion technology and chemical detoxration technoltgy. The specific combustion technologies >o oe discussed h .re are
HONS 221696
TREATMENT and DESTRICTJON OF PCS 133
Liquid imcclion mcinertion, Roury kiln tncineraion, Hifh-tffieiency boileri (for 50 10 500-ppm PCB). Cemcni kilni, Fluidued bed incinerator, Molten uli incinerator. Pyroljiit. and Ocean baled incineration.
In addition to combustion technologies, chemical technologies (including vet oxidation and chemical dechlorination), and exotic technologies (such as microwave plasma destruction) will also be discussed.
Before discussing the various tv pcs of technology available to destroy PCB, it is necessary to examine the pitfalls existing that proposed PCBdisposal operations have encountered and potential methods of over coming them. These are:
1. Exposure of new people to a (perceived) risk has been the most difficult problem to overcome. Basically, the people in the vicinity of the disposal facility perceive themselves as being exposed to an added risk and object to the facility. Even if the people are convinced that the faciliiv will destroy the PCB completely, they object to "the danger of shipping the PCB through their neighborhood." The problem boils down to the statement "waste disposal facilities are needed, and are a good idea, but not near where 1 live." It might be added that people five or more miles from a proposed facility have been known to object to it because they feel that it is too close to them. Even when existing industrial facilities (i.e,, cement kilns, boilers, etc.) have been involved, there has been tremendous local citizen and government opposition. A direct result of this concern is a concern for dr crease m the propem values. After all, a perceived risk does mike this property less desirable. The ideal PCB destruction technology is one that is capable of Being moved to or located at the site where the PCB wastes are being stored.
2. Verification of destruction is oest summarized by the statement: "We're sure you can destroy the PCB during the tesi when all these scientists and engineers are running the process, bui hew can w-e be sure you will destroy them during opercuon--w-e all know that breakdowns occur?" In addition, there are the problems associated with hazardous products of combustion. (HPC): those materials, such as chlorodibenzofurans and chlorodioxins, that form or are suspected of forming when PCB are burned. Combustion is largely an uncontrolled chemical process. As a result, almost any organic material can conceivably be formed. While such an extreme concern seems unwarranted, it must, nevertheless, be considered in the selection of a tecnnologv The tecnnologv of cnoice
HONS 221697
134 I'CB TREATMENT, RECOVERY AND DESTRUCTION
should utilize well understood and controllable destruction methods. Furthermore, the technology of choice should operate in a batch mode. This operation will make it possible to analyze chemically the outflows before release or discharge,
3. Gaseous emissions are released from some sort of stack, which is often associated in people's minds with heavy volumes of noxious smoke. This perception contributes to making people who live miles from the facility fearful of it. To overcome these concc-ns, the ideal PCB destruc tion technology should have no gaseous emissions and only small volumes of aqueous effluent. It is recognized that no technology is capable of managing all forms of PCB and still satisfy these criteria for successful implementation; however, as the following discussions will show, there are certain technologies which, for specific important appli cations, come very close to meeting these criteria.
COMBUSTION TECHNOLOGIES
Currently, the only legal method for disposal of liquid PCB is com bustion in a high-efficiency incinerator or cement kiln. Incinerators must meet the following conditions:
1. either 1200*C. 2-tec dwell tunc end 3% cxceu oxygen, or 1600*C, 1 J-tec dwell ume end 2% excess oxygen:
2. com bunion efficiency of 99.WH end 3. PCB emissions leu then I m(/)c$ PCB detiroyed; 99.99999* destruction remoul
efficiency (DRE).
Only the last condition applies to cement kilns, as ih: temperature, dwell time and excess oxygen in the kiln are all greater than these minima. Cement kilns are considered to be an acceptable method of destroying PCB. In 1976 a series of tests was conducted at St. Lawrence Cement in Canada [2], These tests showed that the destruction achieved was in excess of 99.9996%. Another set of tests, performed in Sweden [3], by Ahling, showed a destruction efficiency in excess of 99.99998%. These values were indicative only of the sensitivity of the measurement method used. No PCB were found. Based on these tests, the PCB regulations permit the use of cement kilns for PCB destruction. No such facility in the United States or Canada has been given a permit for destroying PCB to da;:, largely because of local opposition.
The chlorine from the PCB is converted to hydrogen chloride, which the:, combines with the alkali in the cement. As a result, cement kilns do not require auxiliary equipment for HC1 removal. The sodium, potassium
HONS 221698
TREATMENT AND DESTRUCTION OF TCI 135
and calcium chlorides formed are emiited with the paniculate in the gas stream. They are captured by the air pollution control equipment or emitted to the environment through the suck.
PCB regulations permii the use of high-efficiency boilers for the destruction of PCB-contaminated mineral oil--less than 500 ppm PCB. The restrictions placed on the boiler are:
1. The boiler u reied < minimum of 50 million Biu/hr. 2. The carbon monoxide in the flue (at n 50 ppm or leu for a natural gat- or oti-firec1
boiler, or 100 ppm or leu for a coal-fired boiler. 3. The exceu oxygen in ihe tuck it grtaicr than 5%. 4. The wane it leu than 109 by volume of the total fuel feed. 5. The waste maj only be fed when the boiler is at its full operating temperature--not
during startup or shutdown. 6. The boiler must be monitored continuously for carbon monoxide and exceu oxygen.
If leu than 30.000 gallons of waste oil are burned per year, this monitoring may b replaced by CO and Oj measurements every 00 minutes, 7. The quantities burned and feed ratio of the fuel and waste must be monitored every 15 minutes. I. If the CO and Oj valuta fall below the specified amount, uaste feed must cuk. 9. Approval for tuch bums must be given by the EPA Regional Administrator.
The regulations require additional reporting and monitoring condi tions. Although the number of boilers burning PCB-contaminated oils in the United States is unknown, it is very low. The vast majority of the utility industry is simply storing its contaminated oil.
PCB solids, such as drained transformers, PCB-impregnated capacitors or PCB-contaminated soil, may be landfilled. Before landfilling, free liquid must be drained from equipment (such as transformers) and the equipment must be rinsed with a volume of PCB-free mineral oil equal to ihai drained from the equipment. Landfilling, of PCB solids is illegal and lately to remain so.
To date, despite these permissible options, only two facilities for the disposal of PCB liquids and one for PCB solids have been approved. Local opposition and siting problems are a large parr of the reason for this, although the concerns described earlier factor into the situation.
The problem of greatest concern is products of incomplete combustion (PIC), which are formed in trace quantities. When PCB are burned, chlorinated dibenzofurins (CDBF) can be formed. These results have beer, corroborated in field tests, although these tests have only shewn the CDBF to be in the ash. CDBF have been identified in the stack gases in very low concentrations. Tests on incinerators have identifies dioxins in the suck gases. This uncertainty regarding highly suspect classes of chemicals has made the regulatory authorities extremely cautious and has otlayed the issuance of permits for the incineration of PCB. The nine combustion technologies are summarized in Tabic I.
MOMS 22X699
IM PCB TREATMENT, RECOVERY AND DESTRl CTION
Tibia I. Types of Combustion Equipment for TCB Destruction
Type of Equipment
Applicable Wane Type
Comments
Liquid Injection Incinerator
Liquid PCB, PCB-conuminaied oils, tome eqwous PCBmaienals
The most developed incineration tystems can achieve in eacesa of 99.9999% DRE
Rotary Kiln Incinerator
All physical forms
Very highly developed: can achieve in excess of 99.9999% DRE
High-Efficiency Boiler*
PC B<on laminated watte oils (500 ppm)
Tests show better than 99.99% DRE
Cement Kiln*
Liquid PCB, PCB-conUminated oils
Testa have shown in excess of 99.999991% DRE
Fluidiicd-Bcd Incineraior
Liquid PCB, hifh-vtscosiiy tystems, shredded PCB-utureted paper
Only pilot-scale tesu have been done; may not be capable of reaching high temperatures; senihbers for HD may not be required at limes
Molten-Salt Incinerator
Pyrolysis
Liquid PCB, shredded PCBtaturned paper
Experimental, not fully tested y*t
Too low temperature, not generally applicable to PCB
Ocean-Based Incineration
PCB liquids, PCB-conu minuted oil
Only developed and letted for liquid injection; may eliminate tiling problem but suing of landsupport facilities may be a problem: potentially expensive
CHEMICAL DESTRUCTION METHODS
Liquid-Phase Chemical Destruction Techniques
It appears that some form of liquid-phase cher-.ical destruction tech nique will come closest to overcoming the four oojections to implemen tation of a technology. This is shown by comparing technology classes to the four problems in implementation of PCB destruction technology discussed earlier:
I. Liquid-phatt ivtiemi are imaller than gas-phase s ystemsand, thus, can be taken to ne source of the PCB.
HOMS 221700
TREATMENT AND DESTRUCTION OF PCB 137
2. Liquid'phtK chemical reaction! art controlled much more canly than art gat>phaic reaction* tuch at combutuon. The condition for the dettruelion can thu* be more readily duplicated and hence prtdicied wiih greater reliability.
3. Liquid*phaI* react)ont can be run in a batch mode, to that ditcharget can be analyzed before releate.
4. Becaute of their tmaller volume, liquid>phatc tyttemt lend to have only tmall quantmet of atr cmtttion.
To chemically destroy PCB, it is not necessary' to break completely the biphenyl structure. The degree of hazard, and chemical and biological stability of PCB increase with the number of chlorine atoms on the biphenyl molecule, As a result, dechlorination appears to be a possible alternative to total destruction. This is highly desirable because cleavage of the aromatic biphenyl structure requires a very high energy of activation, and therefore, requires a much higher temperature than does dechlorination. On the basis of this analysis, we can, thus, draw conclu* stons:
1. If wc want to break the biphenyl itructure, only tome form of combustion can provide the necessary conditions.
2, If dechlorination of the molecule is adequate, low-temperaiure wet chemical processes can be used.
The liquid-phase processes that are (at least potential) candidates for the destruction of PCB or PCB-conuminated materials are:
1, sodium/ naphthalene/tetrahydrofuran dechlorination or variations thereof, 2. sodium metal dechlorination; 3. sodium/polyeth) iene glycol (NaPEG) dechlorination; 4, oxidative processes such as wet oxidation or ultraviolet (UV)/ozonation: and $. catalytic dehydrochlorination
In addition, there are concentration techniques available (both adsorption and absorption) for reducing the PCB contamination of oils.
Sodium Treatments
TTte first three processes art very similar in nature. They are all based on variations of the use of metallic sodium to dechlorinate organics, a procedure that is well known. In fact, this method has been used to analyze organics for chlorine. The use of sodium/naphthalene/tetrahydrofuran system was brought to the attention of EPA by Goodyear Tire and Rubber Corporation of Akron, Ohio. They have used it for dechlorination of -10C- to 150-ppm PCB-contaminatec hydraulic and heat transfer oils. It is applicable to the similar dechlorination of any PCB-contaminated oil.
HONS 221701
131 PCB TREATMEM. RECO' ERV AND DESTRt'CTIOV
Variations of this process have been adapted to different types of PCB* conuining material by Acurex Waste Technologies Corporation, General Electric, SunOhio and others.
Goodyear's process uses the sodium naphthalene synthesis ofScottetal. [4], The process involves preparation of a deep green reactive complex of naphthalene and sodium in tetrahydrofuran by melting sodium {melting point, 98C) in a nitrogen-blanketed hydrocarbon oil, chilling rapidly to produce ''sodium sand "(fine spherical panicles) and adding a tetrahydro furan (THF) solution of naphthalene to the cooled slurry. The reagent takes about an hour to form and is added to the oil that is to be treated,
Treatment of an oil containing 300 ppm of PCB at ambient temperature required approximately one hour, after which water was added to destroy the excess sodium. The oil is then vacuum-stripped to recover the TH F and naphthalene, and further distilled, leaving the sodium chloride, sodium hydroxide and the nonhalogenated polyphenyls as still bottoms, which are presumably safe for incineration. The purified transformer or heat transfer oil contained less than 10 ppm PCB. SunOhio has successfully treated transformer oils conuining up to 300 ppm PCB. Acurex has treated oils conuining approximately 1000 ppm during an EPA demonstration and up to 10,000 ppm (1%) PCB during tests. SunOhio and Acurex have succeeded in bringing the final PCB concentration in the oil to below detecuble limits, about 1 ppm.
These are not the only such processes in existence. EPA has been funding a project at the Franklin Institute [3] that is exploring the use of a "reactive sodium-glycolate-oxygen solution" to destroy PCB, In the Franklin Institute process, the reagent is prepared by dissolving socium into polyethylene glycol-400, The reagent i>` then added to the contam inated oil, and air or oxygen is bubbled through the system. The reaction is run at 130 C. Destructions similar to that using the Goodyear process have been reported. The Franklin Institute claims that water does not inhibit the dechlorination reaction; however, this result `^as not confirmed by Napier [6] of Union Carbide at Oak Ridge National Laboratories. The Franklin Institute is now investigating the applicability of this process to PCBconttminated soils.
At the University of Waterloo (Onurio), Smith and Bubbar [7] have applied the sodium naphthalide reagent to destruction of undiluted PCB coruining up to 5591b Cl. They treated a PCB (Arc;lor* 1254) ct nuining 5-.5S* r toui chlorine, achieved 99.89c. which left approximately 2000 ppm PCB after six hours at room temperature. A higher excess of sodium might have brought this down below the level required in the United States; however, this has not been ve'iiied experimenully as yet.
MOWS 221702
TREATMENT AND DESTRUCTION OF TCB l?*
Other sodium treatments have existed for a number of years. The sodium dispersion methods developed by U.S. Industrial Chemicals Com* pany [8] uses the "Dispersator" (a modified Waring blender), MantonGauiin homogemzer or other high*shear mixer. Dispersion is assisted and stabilized by the presence of a dispersion aid such as calcium stearate; dispersion is carried out under a nitrogen blanket. The sodium panicles range from submieron to 200 a in diameter [9], Dispersions of 50%sodium by weight are easily produced by this technique and, because of ihe high surface-to-volume ratio, reactivity is extremely high. In dehalogenation reactions, only about 10% excess sodium is required; additional savings may be realized by eliminating the naphthalene and ether required by the other processes, although a small amount of naphthalene may be employed to "activate" the sodium surface. This approach has not. however, been successful in achieving the low final PCB concentration required by EPA.
Other wet processes that have been or may be used for PCB destruction are wet air oxidation and combined UV light/ozonation [10].
Wet Oxidation
Briefly, wet oxidation is accomplished by adding air or oxygen to an aqueous mixture of organics under pressure and elevated temperature. Pressure serves the dual purpose of keeping the aqueous phase in liquid form and increasing the partial pressure of the oxygen so as to increase the amount of oxygen dissolved in the liouid. Because the temperature involved is considerably lower than for incineration, and also because much less water is vaporized, wet oxidation may require less energy than incineration.
The temperature ranges encountered during wet oxidation are very wide and range from a low of about 300 F for simple sludge conditioning systems to a high of 600 F. Since the pressure of the reactor must be greater than the vapor pressure of the waste at the operaung temperature equipment, pumping and pressure control costs increase rapidly when temperatures exceed approximately 450-500 F. The residence time for these systems ranges from about five minutes to as much as one hour. Generally, as the temperature is increased, the residence time decreases.
While no work has been identified on PCB specifically, Baillod et al. [ 11 ] decomposed peniachlorophenol in such a system. The results of their work are not encouraging. First, ihe temperature and pressures were high, about 6G0F. Second, they identified a number of products of incomplete destruction in significant quantities. As a result, at present, wet oxid; ion could, at best, be considered a pretreatment step.
HONS 221703
1 PC* TREATMENT. RECOVER} AND DESTRl CTION
UV Light/ Ozonation
The combination of UV light and ozone hat shown some success in destroying PCB in aqueous systems. The concept was proposed in 1977 to EPA by Wesigate Research; however, because of the high suspended solids likely to be encountered in actual systems, such a process is not likely to be successful.
Adsorption and Extraction
The final technology to be discussed is adsorption and extraction processes. It is possible to extract the PCB from contaminated oils by the use of a suitable solvent. Napier [6] found furfural to have potential application. Neoprene has also been used in an attempt to adsorb PCB. Napier found this to be ineffective. These concentration techniques must be used in conjunction with other methods for destroying PCB.
Chemical treatment techniques are summarized in Table 11.
Tibia 11. Types of LiqaM-PhiM System* for PCB Destruction
Tip# or CnemUtry
Applicable Wait* Tjrpt
Comments
Sodium NiphihtUdc
liquid PCB. PCB^oruammated
This is well established chemistry; the process has been optimised commercially for PCB contami nated oik costs art %ery high when pure PCB are treated; can be mobile-mounted: no emis sions: low effluent volume' po tential for fire is moderate: cannot tolerate free water
N'aPEG
Liquid PCB. PCB-eontammaied ml. possibility for PCB-eontaminiied toil, possibility for PCB solids
In laboratory state; development under EPA grant; potentially useful in the pretenec of water, requires oxygen end process can release hydrogen, p ant safety factors need investigating
Sodium Metal
PCB-comaminaied oil
Untested as yet but may be promising from theoretical con siderations
Oxidative Procttaci
PCB-contamrruied tods. PCB in an aqueous stream
Degree of destruction it a func tion of temperature and pressure; for PCB destruction, estimated
HONS 221704
TREATMENT AND DESTRtCTIO.N OF PC* 14!
Typ* ot Qiemtttry
Catalytic Dehydfochlon nation
Adsorption on Neoprene Rubber
Adsorption or Extraction
Table 11, continued
Applicable Wuie Type
Comments
Was not successful PCB-eontaminaied oils
PCB-conuminated materials
required temperature and pres sure are in excess of 600* F and 400 psi for *et oxidation, but have noi been ieed: use of water in supercritical state may have potential; UV-oaonanon has had limited laboratory-scale success
Evaluated by EPA project, found not to produce sufficient level of degradation
This process is being marketed: tested at Oak Ridge National Laboratories; wash found not to be effective for adsorbing lha PCB from the oil
New area: tested at Oak Ridge National Labs; aboui 20 solvents tested; furfural found to have potential
CONCLUSION
There are many technologies that appear capable of destroying PCB. The problem* that are usually encountered, however, are rarely technical. In almost every case considered, the problem has been public acceptance of the disposal facility, with objections falling into three categories: (1) exposure of new people to a (perceived) nsk, (2) inability to verify destruction during normal operation, and (3) fear of dispersion of pollutants.
Liquid-phase destruction systems appear to embody ihose attributes that best satisfy the above criteria. These methods appear to stand the best chance of being accepted by the public and of solving the disposal problems associated with PCB.
MONS 221705
142 PCB TREATMENT. RFCO\ER\ and DESTRICT10N
REFERENCES
1. "Polychlorinated Biphenyls (PCBs) Manufacturing Processing, Distribution in Commerce and Use Prohibitions," Federal Register 44(106) (1979),
2. MacDonald, L. P., Skinner, D. J., Hopton, F. L and G. H. Thomas, "Burning Waste Chlorinated Hydrocarbons in Cement Kilns," Fisheries and Environment Canada Report No, 4-WP-77-2 (1977).
3. Ahling, B, "Combustion Test with Chlorinated Hydrocarbons in Cement Kilns,- Swedish Water and Air Pollution Research Institute, Stockholm, Sweden (1978).
4. Scott, N. D., J. F. Walker and V, F Hansley. J. Am. Chem. Soc. 58 2442-444 (1936).
5. Pyilewtki, L. L,, K. Kret its. A. B. Smith, and E. J. Thorne. "The Reaction of PCBj with Sodium. Oxygen, and Polyethylene Gtyeole," in Traruenpts of Sixth Annual Research Symposium on Treatment of Hazardous Waste, EPA Report 600/9-80-011 (1980).
6. Napier. J. M. Paper presented ai the Meeting to Identify Potential Joint EPA-DOE Waste Activities, Washington, DC, 1980,
7. Smith, J. C, and G. L. Bubbar. "The Chemical Destruction of Polychlo rinated Biphenyls by Sodium Kaphthalide," Unpublished paper. University of Waterloo, Ontario,
8. "Sodium Dispersions' U.S. Industrial Chemicals Co., New York. NY. 9. "High Surface Sodium," U.S, Industrial Chemicals Co, New York, NY. 10. "Disposal of Polychlorinaied Bnhenyls (PCBs) and PCB Contaminated
Materials," Electric Power Research Institute (1979). 11. Baillod. R. C., R. A. Lampanes and D. G. Leddy. * Wet Oxidation of Toxic
Organic Substances," paper presented at Purdue Industrial Waste Confer ence, West Lafayette, IN, May 1978.
MOWS 221706
CHAPTER 9
INCINERATION OF CHEMICAL WASTES CONTAINING POLYCHLORINATED BIPHENYLS:
ASSESSMENT OF TESTS CONDUCTED AT ROLLINS ENVIRONMENTAL SERVICES,
DEER PARK, TEXAS, AND ENERGY SYSTEMS COMPANY, EL DORADO, ARKANSAS
Thomas O, Tieman Brehm Laboratory and Department of Chemistry Wright State University Dayton, Ohio 45433
Michael L. Taylor Brehm Laboratory and Department of Pharmacology/ Toxicology Wright State Un'vcrsitv Dayton, Ohio 45%35
Joseph G. Solch. Garrett F. Vanness, John H. Garrett and Mare D, Toner
Brehm Laboratory and Department of Chemistry Wright State University Dayton, Ohio 45435
The Toxic Substances Control Aet (TSCA) of 1976 prohibits the manufacture of polychlorinated biphenyls (PCB) and greatly restricts the uses of these compounds. In 1979 the U.S. Environmental Protection Agency (EPA) published guidelines [1] governing continuing use of certain PCB and disposal of PCB-containing materials. The guidelines for disposal are:
143
MONS 22170?
144 PCB TREATMENT, RECOVERS and destruction
* Liquid! containing <50 m PCB ( ire not regulated. * Liquid! and tolldi containing 50-500 n% PCB/ g may be depouted in an EPA-
approved landfill incinerated in a high-efficiency boiler (producing >50 million Btu iteam/hr) or in an EPA-approved incinerator. * Capacitor! and liquid! containing 500 jig PCB ` g or higher ievtli of PCB mull be incinerated.
The physical, chemical and toxicological properties of PCB form the basis for these regulations.
The characteristic inertness of PCB to thermal degradation (which makes them ideally suited for use as dielectrics and heat transfer fluids) and the resistance of these compounds to degradation in the environment have resulted in a distinct increase in the concentrations of PCB in the environment and in man [2]. This persistence of PCB in the environment, coupled with toxicological effects recently attributed to these compounds, have provided EPA the impetus for PCB regulation. The molecular structures of PCB (Figure 1) are quite similar to those of the chlorinated
/> Cl x
Cl y
Polychlorinoted Biphenyls
x ~'y Chlorinated Dibenzofurans
Figun 1, Molecular imiciurtt of PCB. chu.'mated dibenio-p-dioxini *nd chlorinated d i be mo Turin!
HOMS 221708
jvcineratton of res U5
dibenzo-p-dioxins (COO) and chlorinated dibenzofurans (CDF), some of which are known to be extraordinarily toxic. Indeed, recent reports have appeared that indicate that the TCB can, on heating, be converted into COD and CDF [3]. It is not surprising, therefore, that the toxicologic properties of some PCB are similar to those of some COD and CDF [4,5].
The resistance of PCB to thermal degradation makes efficient incinera tion of these compounds quite difficult. Moreover, the possibility of interconversions of the PCB to CDD and CDF, which can occur during incineration [6], makes it mandatory to ensure that incineration of these compounds is accomplished under optimum conditions. In recognition of this fact, EPA has specified that incinerators used for disposing of PCB must be operated at very high temperatures. Even under such conditions, however, it has not been established that emissions of toxic compounds, such as CDD and CDF, are essentially precluded. Recently, EPA conducted test burns of PCB at two chemical waste destruction facilities in the United States in an effort to assess the efficiency of incineration as a destruction technique for PCB. This chapter describes the two inciner ators used in these tests and the relevant operating parameters. In addition, the sampling and analytical procedures developed and imple mented to determine levels of toxic chlorocarbons (primarily CDD/CDF) emanating from the stacks of the two incinerators during these tests are discussed. Finally, the levels of CDD/CDF thst were determined to be present in the suck effluents are reported, and the results of the risk assessment for the incinerators that was accomplished by EPA using the latter data are summarized.
DESCRIPTION OF THE INCINERATOR FACILITIES 4.ND TESTS CONDUCTED
The incinerator facilities employed for the PCB destruction tests described here are located at El Dorado, Arkansas, and Deer Park, Texts, and tre operated by Energy Systems Company (ENSCO) and Rollins Environmental Services, respectively. The two incinerators, which are somewhat similar in terms of operating capabilities, are depicted schematically in Figures 2 and 3. A detailed description of these inciner ators has been provided in the plan for testing developed by the EPA's sampling contractor, TRW [7], and will be mentioned only brief!) here, to provide a basis for discussion of the various types of samples that were roilected during the monitoring tests.
The incineration system utilized by Rollins consists of ; rotary kiln and a hiuid injection burner, both feed.ng a common afterburner. Tempera-
MOMS 221709
l fc T R E A T M E N T . F E f O ' ER l A N D D E S T F l CTION
OLIO MAITIi rcco ciwtx
AfcSOflBTIOH
nmtt
Mm tLi#ijMMot
OXXwl6-w*rr mcx
t l|ui 2*
, liquid tun
ICMKI *ATU
Schefttaitt of KnJItns Environmental Semcti incinerator
MOMS 221710
iri aoj jo N o u vm so si
Hcu' J. bilitiiuiic of Ihc ENSCO iiKiMiilua
HONS 221711
141 PCB TREATMENT. RECOVERY AND DESTRl CT10N
lures attainable in these three burners are normally 1300-1500C. The overall retention time of the incineration system is 2-3 seconds. Solid wastes can be fed into the rotary kiln by conveyor (although no solids were burned during the tests described here), while liquids and sludges are pumped into the kiln or into the liquid injection burner. Natural gas is used as an auxiliary' fuel for initial heatup and to provide supplemental heat for incineration of low-heat-capacity wastes. No. 2 fuel oil is also used to provide heat for burning materials such as PCB. and is mixed with the PCB before the waste is fed into the incinerator. Gaseous emissions from the combustion of solid and liquid wastes arc controlled by a venturi scrubber. Lime is injected to neutralize the scrubber water, w hich is then admitted to settling ponds, where the water is analyzed and subjected io further treatment, if necessary, before discharge into the Houston ship channel. Exhaust gases are also routed through absorption traps and a mist eliminator before entering the 30-m exhaust stack.
The incineration system used by EN'SCO is also capable of combusting both solid and liquid wastes. This incinerator consists of a rotary kiln, in which combustion temperatures of 1200-1500 F arc attained, and in which the retention time for solid material is approximately 1 hr and the gas retention time is approximately 4 sec. Liquid wastes, water and natural gas can also bi injected into the front end of the kiln. Ash is removed from the end of the kiln by a drag chain and placed in steel drums for storage. Gases evolved from the rotary kiln pass into an afterburner that consists of two separate combustion chambers. Resi dence time in the primary chamber is approximately 2.2 sec. and tempera tures of 2250-2340*F are typically maintained there. Most of the organic waste materials are destroyed in this region. Molten slag resulting from the combustion settles on the chamber floor and is removed through a slag trap. The secondary combustion chamber is baffled to facilitate gas mixing, and the residence time ir this chamber is approximately 2 sec. while the temperature is typically 1400 F. The total residence time for gases in both chambers is about 4.5 see. The scrubber at the ENSCO facility is also a venturi jet tyre. Gases evolved Pom the combustion chamber are quenched w-uh lime and caustic solution as they enter the bottom of the scrubber. This treatment removes particulates and neutral izes acidic gases such as HC1. Spent scrubber liquor is transferred io a holding tank w'hich then overflows to a sludge lagoon. Spent scrubber solution :s available for recyciing. After neutralization, the combustion gases pass ihrough the vemuri section of the scrubber, in which recycled scrubber water is sprayed io facilitate particular removal. Ultimately, sludge and liquids from the lagoon are discarded by deep-well injection.
HOMS 221*12
incineration of i*cb h*
Sampling and monitoring were accomplished by the sampling con tractor during three different modes of operation at each of the inciner ators tested. The materials combusted and the conditions for each of these tests are as follows.
Test 1
For test l.each incinerator was operated under the conditions at which incineration is normally conducted. Temperatures in this case were not necessarily maintained at 1200C as required for PCB incineration. At the Rollins plant, the materials combusted were liquid chlorinated hydrocarbon wastes, such as vinyl chloride still bottoms. At the ENSCO plant, shredded capacitors (solids, but not containing PCB) were in cinerated, along with chlorinated hydrocarbon wastes, such as pesticide process wastes, as well as paint and ink manufacturing wastes.
Test 2
For test 2, the materials combusted at the Rollins incinerator consisted of the same types of materials as described for test I, along with liquid PCB wastes. Similarly, at ENSCO, the test 2 incinerator feed included the normally processed wastes (as in test 1) along with liquid PCB and shredded PCB-containing capacitors. Combustion temperatures for test 2 were maintained near 1200BC at both plants, as required by EPA regu lations for incineration of PCB.
Test 3
For test 3, the materials combusted at Rollins consisted of a mixture of liquid PCB wastes and clean fuel oil. At the ENSCO plant, the materials incinerated during test 3 included liquid PCB wastes and PCB-containing capacitors, mixed with diesel fuel. Again, temperatures were maintained at the levels required for PCB incineration.
SAMPLING PROCEDURES AND TYPES OF SAMPLES COLLECTED
The sampling procedures and apparatus utilized in the monitoring tests at the Rollins and ENSCO incinerators have been described in detail in documentation prepared by TRW [*]. and only those aspects which relate
HONS 221713
1<0 TCB TREATMENT, RECOVERY AND DESTRt CTION
to the simples ultimately analyzed by bright State University will be summarized briefly here. Stack Effluent Samples
Stack effluents were collected by using a modified EPA Method 5 sampling train, shown schcmoiically in Figure 4, which consisted of a glass probe (capable of being heated to 250F), followed by a series of three glass impingers (the first containing 100 ml of distilled water, the second containing 200 ml of distilled water, and the third, empty), a sorbent trap containing XAD-2* resin, a sorbent trap containing Florisil* and a fourth impinger containing silica gel. A schematic representation of the traps is shown in Figure 5. The train was backed by appropriate gauges, valves, meters and a pump, for controlling and moni toring flow through the train. No filter was inserted between the probe and impingers, so any particulates collected entered the imptngers and
Figuri 4. Modified method V' '-rain uitd to sample combustion effluents from the ENSCO and Rollins incintnori.
HONS 221714
ri/yn DIRECTION
------------>.
INCINERATION OF Pti Jfl
cu
Flfut 5. Schematic of sorbent trap employed in the modified method V train.
were immersed in ihe liquids. The impingers were cooled by immersing them in an ice bath to condense moisture from the stack effluent stream. The sorbent traps were also cooled by circulating chilled water through the exterior jackets. The sorbent traps incorporated a glass fritted disc on one end, which retained and supported the sorbent bed, and the sorbent was held in place by a glass wool plug at the other end of the trap. The traps, as well as the probe and the impingcrs, were interconnected using standard glass ball and socket joints, which were not greased for these tests. All components of the sample train were rigorous!) cleaned, using standard procedures, before use.
On termination of a stack sampling event, the probe was removed from the stack and, the train was disassembled. The nozrie and glass probe were rinsed with approximately 100 ml of acetone and 100 ml of hexane, and the interior surfaces were scrubbed with a nylon brush. The rinses and any materials removed from the probe were transferred to a prerinsed amber glass bottle and the bottle was sealed with a Teflon**-lined cap.
`Registered trademark of E. I. du Pon: oe Nemours and Company. Inc. Wilmington. Delaware.
HOMS 221715
152 PCI TREATMENT, RECOVERY AND DESTRUCTION
The contents of the first three impinger* were pooled by pouring the liquids into a single amber glass bottle. The intenor chamber of each impinger was rinsed successively with 30 ml acetone and 30 ml hexane and these rinse solutions were placed in the same bottle containing the collected impinger liquids. Rinsings of connector tubing were also placed in this container, which was sealed with a Teflon-lined lid. The XAD-2 and Florisi) sorbent tubes were removed and sealed by placing mating ground glass caps on the end joints of each tube. Appropriate solvent and water blank samples were also collected during the tests and placed in scaled amber glass bottles. Several method blank samples were also obtained by charging and assembling a complete train, then dissassem* tiling the tram components (unused) and collecting the appropriate samples.
From the foregoing, it is seen that five types of samples requiring analyses for CDD, CDF and PCB result from the stack sampling. These types include the probe wash, impinger catch and rinses (composite), XAD-2 resin traps, Florisil traps, and solvent and method blanks.
Solids and Liquid Samples
Concurrent with the stack sampling samples of appropriate solids and liquids relevant to the incineration process (feed materials, combustion products, emission control equipment samples) were also collected by simple grab sampling Such samples were collected at appropriate intervals during the incineration tests, and were placed in prerinsed amber glass bottles and sealed with Teflon-lined caps. The time and resources allotted to Wright State University for this project by EPA permitted analyses of very few of the latter samples, and non: of the data relevant to these are presented here.
ANALYTICAL METHODOLOCY
Sample Handling and Preparation
Samples collected as described above were shipped from the sampling sites to the Brchm Laboratory, Wright State University. Certain liquid samples from the sampling trains (probe rinses and impinger samples) contained two distinct layers; in one case, suspended solid material was visible. After allowing such samples to stand for a period sufficient to effect complete separation of the layers, each layer o' these samrles was removed to a separate ;.mber glass sample container ;.;;es with a Teflon-
HONS 221716
INCINERATION OF PCS 153
lined lid, so that each phase could be analyzed separately. The quantities of the liquid phases varied considerably from sample to sample, and in a few instances, only one layer was present. It is not known whether these variations were due entirely to leakage of the sample containers (which did occur in many samples) or to variations in the sampling train operation and rinsing procedures applied in the field. The separated liquid layers were subsequently processed as described below and ana* lyzed.
The XAD-2 resin and the Florisil traps were sealed with glass caps by field sampling personnel, and the traps were shipped intact to the Brehm Laboratory. Before analysis of the trap contents, the XAD-2 resin or Florisil was removed from each trap and transferred to a clean amber glass vessel fitted with a Teflon-lined cap. Each individual sample was thoroughly mixed before removing an aliquot for analysis in an effort to ensure homogeneity and representative sampling. In all cases, both the XAD-2 resin and Florisil appeared to contain substantial quantities of water (although the quantity varied from sample to sample) and the solid sorbents were agglomerated and difficult to remove from the traps. In fact, some quantities of the sorbents adhered tenaciously to the inner surfaces of the traps and could not be removed. The quantities remaining could not be determined and related to the original weight of resin, because the weights of the individual traps prior to packing and the weight of the water absorbed by the solid sorbent in each trap, could not be determined reliably. Consequently, there is uncertainty in the reported analytical results arising from the fact that these data do not take into account the residues of the sorbents left m the traps. However, the quantities of these residues were generally small (probably less than 2 g). No attempt was made to dry the XAD-2 or Florisil samples before analysis, since it was thought that this also might lead to loss of volatile chemical compounds trapped on these sorbents. The total weights of the sorbents taken for analysis also were determined, and by relating these aliquots to the total quantity of sorbent removed, the total burden within the trap of the compounds analyzed could be determined.
Another factor that bears on the accuracy of the reported data for the XAD-2 resin and Florisil traps should also be mentioned. It was observed that the glass frits of the traps received by the Brehm Laboratory had been perforated, and in some cases exhibited nonuniform holes of varying sizes. Apparently, according to information received from the sampling contractor, the frits were perforated during the actual sampling tests because the frits plugged and the desired flowrate through the sampling train could not otherwise have been achieved. These observations raise questions about the uniformity of exposure of the solid sorbents to the
HOMS 221712
154 PCI TREATMENT, RECOVERY AND DESTRUCTION
gat stream during the sampling process. The colorations observed in various pans of the traps also raise similar questions. Several of the traps from the tests at the ENSCO plant exhibited a pronounced red*brown coloration on the frit and on the glass wool plup at the other end of the solid sorbent bed, but the sorbent itself appeared to have retained its characteristic stark white color. This was observed for both the XAD-2 resin and the Florisil traps. Similarly, many of the Rollins traps exhibited a bright yellow color on the frits and the glass wool plup at the other end of the sorbent bed, but the sorbents themselves appeared to be stark white with no indication of the yellow color. In the case of traps originating from test 3, at the ENSCO site, the frit was covered with an oily residue (gray in color) but apin the resin appeared to be "dean.**
As noted above, small quantities of the solid sorbents could not be removed from the traps. Also, the colored contaminants that appeared on the glass frits of the traps as well as other solid deposits on the trap walls remained in the traps after the bulk of the sorbents had been removed. Since it is important to know whether or not these residua may include CDD, CDF or PCB, attempts were made to extract these residues from one trap by immersing the entire trap (after the sorbent had been removed) in a very large soxhfct apparatus and employing the extraction procedures described below. The extract was subsequently analyzed to determine content of the compounds of interest and was found to contain insignificant concentrations of CDD/CDF.
A few of the solid samples (feed materials, etc.) were analyzed as received. Aliquots of these were removed from the sample vessels in which the samples were received and weighed. Apin, attempts were made to ensure that a reasonably representative sample was selected, but with the coarse solid feed materials (for example, shredded capacitors) and the viscous scrubber samples there is no certainty that this was achieved.
Analytical Methods Development and Testing
At the outset of this program, analytical methods to accomplish quantitative measurements of the CDD, CDF and PCB in samples of the type collected in this assessment had not been demonstrated. In fact, a complete survey of combustion effluents for all classes of CDD and CDF had not been reported by any laboratory in the United Statu. Related studies (8) reported quantitative data on CDD, including some informa* tion on isomeric composition of the tetrachlorinated dibenzo-p*dioxins (TCDD), for effluents from a municipal refuse incinerator, Other workers had also reported the results of comprehensive studia of CDD in various combustion products 9,10], The samples collected in the Rollins/
HONS 221718
OClN'EJtATTON OF FC* 155
ENSCO tests, however, encompass a much broader array of sample types than have previously been examined in such surveys. Accordingly, it was necessary to develop and test the efficacy of analytical procedures that could be applied for the required analyses.
The approach adopted by this laboratory for developing the needed analytical procedures entailed initial application of methodology similar to that which we have applied previously for combustion products and other hazardous waste samples containing CDD, To gauge the efficacy of these procedures, portions of samples were spiked with known quantities of J7CU-2,3,7,8*TCDD, and other stable isotopically labeled CDD, and the samples were then analyzed to determine the recovery of these CDD. If recoveries were not acceptable (usually a minimum recovery of 30% of the added labeled internal standard was used as a criterion of acceptabil ity), the extraction and/or cleanup procedures were modified, and another spiked sample aliquot was analyzed using the modified methods. This procedure was repeated until recovery of the added CDD was acceptable. It was not possible to accomplish the same type of tests for the CDF, because no labeled CDF was available or could be obtained for use as an internal standard in the studies reported here. A limited number of experiments were conducted with CDF using the method of standard additions, in which a given sample was analyzed before and after addition of a known quantity of an unlabeled CDF standard. The methods ultimately developed and validated for the determinations reported here are described in the following sections.
The extent to which information on the CDD and CDF isomers present in the samples could be obtained was limited by the availability of pure standards of the isomers which could be used for comparisons of gas chromatographic retention times and mass spectral response. Of the total 73 CDD and 133 CDF isomers which are possible, only 33 CDD and 10 CDF were available in our laboratory at the time of this study. A listing of these is given in Table 1. In addition, it is seen that four other isotopically labelled CDD are on hand.
Extraction of Samples and Preliminary Separation of CDD, CDF and PCB from Other Matrix Constituents
The procedures developed and applied for extraction of the samples and preliminary separation of the compounds of interest are as follows.
HONS 221719
ISC fc* TREATMENT, RECOVERY AND DESTRUCTION
Tibia I. CDD uC CDF Imomt SliMirA A*iiliMt it Ik# Brtkai UkMIwj i Ik* Ttm* of Ik* ENSCO wC RoUia* Stud*
1 Chlorod ibnl-^-dioxi 2-Ckloro4ibmto-^4ioxio 2,7'Dichlorodikcfuo^dVoaia 2J~Dichloro4ib*nto-^diovin I,2,4-Trichlofodib*fUO-^-do*io Teinchiorodibtnzo-^-dioiiiu (all 22
iiomcn) 1Ta4-Ttraehlorodib*iuO'P-dioaui ,JC-2,3.7,l-TetrHhloro4ikcfi20>p-d toxin NC-24,7,l*Tetfaehlorodi btiuo-p-dioiio J,2,3.7 ,l*Reiiuchlor odikcixo>p>dioxM 1,2,4,C,7,9-Htuck)orodikcuo^-dioaia 1.2,3,4,7,1-Hfxachlorodibcuo^dioxiii
1,2,J.4,C,7-HtacMorodikcnio^-dio*ia 1.2,3.4,6.7.t-Hrpi*chk>rodib(nzo-p-dioiii
3,Clrl .2J,4,6,7,S-Hepuchlorodibtnxo-p. dioxin
Oi chlerodibcaio-pdioxi a ,,Clt-OcMchloro4iktnw-/4ioxm 2,4>Dichloro4ibmofun a 3,6-Dkhlorodikctuofunn 2,1'Dtchlorodi bciuofuna 1,2,4-Trkhlorodibciuofuraa 1,2,44-Titrachlorodibouo Turin 2J .7,I-Trchlorodibuofaraa 1,2.4,7,S-Penuchtorodibciuofan n
l4,4,6,7,9*Htaiehlorodibcniofuna l,24,4,CJ,9>HcpiaelitefOdlb(iuo/uraa Ocuehlorodikcnioraraa
Extraction
Liquid Samples. Measure the total volume of the liquid sample. Transfer approximately half of the total sample (or up to 40 ml) to a precleaned 125-ml amber glass bottle. Add appropriate quantities of the internal standards [37CU-2,3,7,8-TCDD and 37Cl-1,2,3,4,6,7,8-hepta* chlorodibenzodioxin (HpCDD)J. Add 40 ml of petroleum ether, seal the vessel tightly with a Teflon-lined cap, and agitate the vessel vigorously on a laboratory shaker for a period of one hour. Proceed with cleanup and liquid chromatographic (LC) separation.
Solid Samples. Accurately weigh an aliquot of the XAD*2 or Florisil sorbent (or other solid sample) corresponding to approximately half of the total sample (typically 5-13 g), place this in a precleaned glass thimble, and add appropriate quantities of the internal standards (3TCi2,3,7,8-TCDD and "04-1,2,3,4,6,7.8-HpCDD), directly to the sample in the thimble, Insert the thimble into a precleaned soxhlet apparatus, charge the soxhlet reservoir with 100 ml of benzene, and apply heat to the reservoir to extract the sample. Continue extraction for a period of 16 hours. Remove the extract and concentrate to a volume of about 5 ml using a Snyder column. Transfer the concentrate to a precleaned 125-ml
MOMS 221720
INCINERATION OF FC 1ST
glass bottle and add 40 ml of petroleum ether. Proceed with cleanup and LC separation.
Cleanup and LC Separation
Add 50 ml of bidistilled water to the vessel containing the sample extract, reseal the vessel and agitate for ten minutes. Allow the vessel to stand for a period sufficient for the aqueous and organic layers to separate completely, and remove and discard the aqueous layer.
Using the same procedure as applied in the preceding paragraph, wash the extract successively with 50-ml portions of 20% KOH, bidistilled water, concentrated H2SO4 (except in this case agitate mixture for 15 min), and bidistilled water, in each case discarding the washing agent. The acid washing procedure is repeated until the add layer is visually colorless.
Add 5 g of anhydrous sodium sulfate to the washed extract and allow it to stand, to remove residual water. Transfer the extract to a centrifuge tube and concentrate to near-dryness by pladng the tube in a water bath at 55"C, and passing a gentle stream of filtered, prepurified Nj over the solution.
Prepare a gl*M macrocolumn, 20 mm o.d. x 230 mm in length, tapered to 6 mm o.d. on one end. Pack the column with a plug of silanized glass wool, followed successively by 1.0 g silica, 2.0 g silica containing 33% (w/w) 1 M NaOH, 1.0 g silica, 4.0 g silica containing 44% (w/w) con centrated H2SO4 and 2.0 g silica. Quantitatively transfertheconcentrated extract from the previous paragraph to the column and elute with 45 ml hexane. Collect the entire eluate and concentrate to a volume of 1-2 ml in a centrifuge tube, as before.
Construct a disposable LC minicolumn by cutting off a 5-ml Pyrex* disposable pipette at the 2.0-ml mark and packing the lower portion of the tube with a small plug of silanized glass wool, followed by 1 g of Woelm basic alumina, which has been previously activated for at least 16 hours at 600"C in a muffle furnace, and cooled in a desiccator for 30 minutes just before use. Quantitatively transfer the concentrate from the previous paragraph onto the LC column, rinse the centrifuge tube con secutively with two 0.3-ml portions of 3% CHjClrin-hexane, and also transfer the rinses to the chromatography column.
Elute the column with 10 ml of 3% (v/v) CH2CI rin-hexane and retain the eluate for PCB analysts. Elute the column with 10 ml of 50% (v/v) CH^Ch-in-hexane and retain the eluent for analyses for CDD and CDF.
HONS 221721
151 rc TREATMENT. RECOVERY AND DESTRUCTION
Elute the column with 5 ml CH^Clj and retain the eluate to check for retention of CDD and CDF on the column.
Concentrate each of the retained fractions to a volume of approxi mately 1 ml by heating the tubes in a water bath while passing a stream of prepurified N] over the solutions, as described above. Quantitatively transfer the concentrated fractions into separate 2-ml microreaction vessels, splitting each fraction so that half goes into each of two sample vessels. (The contents of one vessel are analyzed for CDF, and the contents of the other for CDD.) Evaporate the solutions in each of the microreaction vessels almost to dryness, using the procedures just men tioned, rinse the walls of each vessel with 0.5 ml CH2CI], and reconcen trate just to dryness.
Approximately 1 hour before gas chromatographic/mass spectrometric (CC/MS) analysis, dilute the residue in each microreaction vessel with an appropriate quantity of benzene (depending on the anticipated quantities of analytes in each vessel) and gently swirl the solvent in the vessel to ensure dissolution of CDD, CDF and PCB.
If preliminary CC/MS screening analysis of the sample indicates the presence of potential interfering compounds (e.g., those that obscure the CDD, CDF or PCB signals) or other sample matrix constituents having very long CC retention times, then additional sample cleanup or frac tionation is required using high-performance liquid chromatography (HPLC). The HPLC used for this purpose is described below. The sample is injected into the HPLC apparatus and appropriate fractions are collected, as determined in advance, by injecting pure CDD and CDF standards and measuring the retention times of these.
Analysis of Sample Extracts Using GC/MS
Two separate CC/MS methods of analysis were employed in this study, one utilizing low-resolution gas chromatography/high-resolution mass spectrometry (LRGC/HRMS), and the other utilizing high-resolu tion gas chromatography/low-resolution mass spectrometry (HRCC/ LRMS). For determination of total TCPD in the extracts of the samples, LRCC/HRMS was employed. This technique provides a generally reli able quantitative indication of the total levels of TCDD present in the analyte (assuming that the instrument response is the same for all TCDD isomers), but does not yield information regarding the quantities of specific TCDD isomers present For these analyses, a modified AE1 MS30 mass spectrometer, operated in selected-ion monitoring (SIM) mode.
MOHS 221722
INCINERATION OF PCS IS*
is used. This technique utilizes i specialized step-scan circuit and asso ciated electronic hardware developed in this laboratory and described in previous publications. Both m/z 319.8966 and 321.8936 are monitored as indicators of TCDD during the period when TCDD elute from the gas chromatograph. Thus quantification of the TCDD detected can be based on the signal observed at either mass. The theoretical ratio of m/z 319.8966 to m/z 321.8936 resulting from CDD (based on the known isotopic abundances of "CI and J1C1 and the numbers of Cl substituents in the molecular ion) is 0.77, and the experimentally observed ratio should be essentially the same as the theoretical ratio. This isotope ratio is another criterion that the data should satisfy to certify with confidence that TCDD is indeed detected. Since the ion signal at m/z 327.8846, which arises from the 37Cl4-2,3,7,8-TCDD internal standard added io all samples prior to processing, is also monitored concurrently with the two masses typical of native TCDD, and the quantification of native TCDD is actually based on the ratios of the signals at m/z 320 and m/z 322 to that at m/z 328, the TCDD data obtained are inherently "recovery-corrected.'* This is, of course, one of the chief reasons for using an internal standard, and results in improved accuracy. The percent recovery of the internal standard is specified in the data listings solely for the purpose of illustrating the overall efficiency of the analytical procedure.
For determining the total concentrations of each of the various other classes (penta- through octachlorinated) of CDD and CDF in the sample extracts, a sophisticated HKCC/LKMS technique was employed. A complex, computer-controlled SIM scheme was used for this purpose and the compounds in each extract were quantified during two separate CC/MS runs. The ions monitored during these CC/MS analyses for each group of CDD and CDF are listed in Table 11, while the sequences of GC and MS operations are shown in Tables 111 and IV for the two runs. These procedures permit the monitoring of ion masses characteristic of each class of CDD and CDF during the appropriate GC retention time interval. As expected, the monochlorinated CDD and CDF have similar retention times. However, use of a 50-m wall-coated open tubular fusedsilica GC column provides optimum separation and minimizes overlap of individual compounds. As mentioned earlier, of the 75 possible CDD and 135 possible CDF, authentic standards of only a limited number are available in our laboratory for use in calibration (see Table 1). Therefore, most of the CDD and CDF peaks observed in the analyses of the sample extracts cannot be assigned to a specific isomer. Thus, in arriving at a quantitative estimate for a given class of CDD or CDF, the areas of the mass chromatographic peaks appearing at the appropriate retention times, and having the appropriate mass spectral response, were summed
HONS 221723
1*4 PCI TREATMENT, RECOVERY AND DESTRUCTION
Table II* Ion Mau*t Monitored Using SIM CC/M5 for ShmlUMota Determination of Mono* ihroufk Octechlorinated DIbtni-?-dloxlne end Dlbeniofurane
CtlM Of Chlorinated
Dtbtniodlovln or
Dibtniofurtn
Number of Chlorine
Subetltuenta
(X)
Monitored m/i for
Dlbeniofurane CnH^OCl,
Monitored m/i for
Dlben io-p-dlotlne
C||HM0,a.
Approximate Theoretical Ratio
Expected on larit of leotopte Abundance
MonoDiTriTetre*
PonteHex*Hepta-
Ocu-
1
202.019*
211.013*
204 014
220 011
2
233.980*
231.974*
237.977
233.972
3
269 941*
283.940*
271.938
2S7.937
4
303.902*
319.197*
303.199
321.194
J27.8S5*
[236.933]*
[258.930]*
3
337 163*
333.138*
339.160
333.133
* 373.121
389.116
373.111
391.813
7 *07.782 423.777
409.779
423.774
431.763*
1 441.743 437.738
443.740
439.733
1 00 0.33 1.00 0.69 0.99 1.00 0.77 I OO
0.21 0.20 0.57 1.00 1.00 0.87 1.00 1.00
0.86 1.00
'Molecular ion P*. *J,Cle-ltbelcd TCDD and HpCDD nandard peak*. 'lorn that can be monitored in TCDD analytes for confirmation purposes.
and compared to the corresponding area observed from injection of a known quantity of a calibration standard of the same class. In general, a single CDD or CDF isomer of each chlorinated group (monochlorinated, dichlorinated, etc.) was used in the calibration process. However, since all 22 TCDD isomcra are available in this laboratory, it is possible to make a reasonably definitive identification of most of the TCDD isomers present in the samples, because the techniques employed permit complete separa tion of most of these isomers.
Sample extracts expected to contain PCB were also subjected to HRGC/LRMS analysis, using SIM. PCB standards representative of several classes of PCB (mono- through decachlorinated) were used to calibrate the CC/MS and to determine appropriate CC retention time
HONS 221724
TiMt III. Sti]Mntt ot Opnallom III GC/M5 (MS-iJ) AMlfitt p4 CUD anrf CDF In Flnt Inj'tllM of Samplr CairKt
1 It^rl 11** <** tot 1 Jt 1N M m
lit I ti f ft
fAAt 1*0
Htt MJt o.
MM tilt
1 iflH
Iw* Ml IpM ttll Hrfta UMf pa^fitM I* IlfC Ofvn (tain (W* ( $1*11 piH-- I: iiitf HU ppm;
tM Ml lltl HN ( 111 M
cc llwM IllfllHWI
<*L|
m in I0> Ml
MS
fikpiai *wN*l
hit
!tl*p
1
Siam paAffin > mr|i r JOt
(tun mi ml mn M wt
IM IM
Ot
ii*ii apftM* } $(iri pi*ti % *w*ip * 01 ppm.
lnn m prMA mail * 11 at. mm mm *'(.>ICtK> II! in
If|ki inif H*fiw m U3*C Stop H flip 1 tUN pafH* tj imf JIJ ppM,
tine M nrii mu i|)Ih
>M
IM us >!S
Siw pun ) RHMi OC la Mi WW Naif
ImftrHai frtpin Im
p*C/** I 1 1
1
Of Km dfwlnnilii
(n/O
Mill* JMMI ItttU MLMI
IHM Jlf tit MS M# MtfST
suns . SJ! MS
UtM SSI IS* JSS.US
MS 111 4m.rn mm MS,!M IS* MS
tiltHHl
IlHuOlum Mm Cl fMH
Hm Cl Ami
n, Am Oi Imam O, iMtn Ch <*M(M na-Mtk* icoo Ctf Imam Of Imam C1| Miu Of Oaaam
O, Au Cl, )um Of tWIM* Of thatoa `'CVMtM HfCOO
INCINERATION or
r c i 1*1
HONS 221725
rC TREATMENT. RECOVERY AN D DESTRUCTION
Tofcl* IV. Stt|U(nt of ()p<fltons hi GC/MS (MS--25) Aooljif* of COD tod CDF to 5moo4 la|*ctlM of Simpl* Citmt
llM IfftNlp
m IN MO < tot
fttm
lijMNM. ipMru In m ifN Oryta may payai a UfC Oft* iW* m UNH pNrw 1 ffp * ttfl ffm.
ilM m *cN Mr *()*
cc Cmmm TMfK*Nn
PO
t* Iff IN m m
TMpnNvt fMf Rm ti*cyN4
i )
IN
im tin
('ftiam learMfi
Mri MnfctiHNl
Riff J Mm pFfm ifrf * ffN pn
tMn mO mnt illlvr. hm
aa "CMtlMl ! an
IN m
IN
XN 11 m nm
Krfib itMf pnw> * M)*C
Rim pn*i* * >kttf I1* fpw Mm m ikM mm iIHm
IN IN
111
s s
*im urn
'lap r" `
Him
1 nf Ilf pfMC
lim aa uA aia 1.111 at
) 11*
f*m NJO
mm
Rhf HN1** 1 SMan pnh 1 i*np US fp;
Mm* cm mm * *JJ **
RMf ptaptlH lna im NmmiI irnf
Ml Ml
Mi
II
Im Wl)
Ml *M Ml 914 IM HI
jimi Jtoift
J2t m MTJIl
)| in ii mm Ml III
47 m m rn *u m Mm IN Ml 44| Ml 44) Ml 4)1 Ht 4)9 )J)
0| hiiw Of Mm 0| mrnim 0| NN
Cl, law* Ct| Pint Cl* 4*611-- Cti Mhh "ONIlM led*
(\ Mm <\ Min n* 4fMu tV Mm
Ot Mm Ch Min Cl, Oaaiat Of 4m*w *CUMI HfCDO Cl,l-am ci, f-- Cl* 4fni-- Cl, Miaa
HONS 221726
INCINERATION OF PCi H3
parameters and sensitivities for each PC8 class. The mass spectra) ions indicative of each PC8 class that were monitored at the appropriate retention time are shown in Table V. The same monitoring sequence was applied to the sample extracts to estimate the quantities of lotal PCB of each class that were present.
Immediately before analysis, each sample extract was diluted to the desired volume (typically 10-50 #j1) and I- to 10-pl aliquots of each sample extract were injected via a microsyringe into one of the gas chromatographs.
Specific details follow of the apparatus, operating conditions and experimental parameters for the CC/MS analyses reported here.
Parameters for LRGCjHRMS Analysis of Sample Extracts
Instrumentation. A Varian 3740 gas chromatograph coupled through an Associated Electric Industries (AE1) silicone membrane separator to a modified AE1 MS-30 mass spectrometer. Modifications to the MS-30
Tablt V. loa Masses Monitors* U4* SIM GC/MS for Simultaneous DctcrminatlM of Mono- threiifli Oeeschlorinats4 fCI
Class l Chlorinats*
PC* MonoDiTH-
Teira* Penis-
HcxaHrpts-
Oct1-
NonaDecs-
CMoHm Sebstkaonts
1 1 3 4 s 6 7 s 9 10
loos Monitors* <ss/i) lor PC* [C,,H^aJ
1M.039 190 036 122.000 22J.997 233.961 237.93* 2S9.922 291.919 323 1*0 J27.*77 339141 361 *39 393.102 396.100 427.763 429 761 463 722 463.719 497 613 499 6*0
HONS 221727
164 PC* TREATMENT. RECOVERY AND DESTRUCTION
include t new ESA power supply and incorporation of a custom-built step-scan circuit driven by a Nicolet 1074 Signal Averaging Computer. Four masses are rapidly scanned at the retention time of the dioxin or furan of interest.
Conditions for the Gas Chromatograph. The column was a 1.8-m 2 mm i.d. glass column packed with 1.5% OV-IOl on Gas Chrom Q (100/120 mesh). The carrier gas was helium at a flowrate of 30 ml/min. The temperatures were injector, 250C; column, 220C; transfer lines, 285 C.
Conditions for the Mass Spectrometer. Ionizing voltage was 70 eV; static resolution was 1:12,500 (10% valley); source envelope pressure was. 5 "10** torr; analyzer pressure was 5 10-6 torr, source temperature was 250C; membrane separator temperature was 215C; transfer line tem perature was 270*C; and ions monitored were m/z 319.8966, 321.8936, 325.8805 and 327.8846.
Parameters for HRGC/LRMS Analysis of Sample Extracts
Instrumentation. A Perkin-Elmer Sigma HI gas chromatograph was coupled through a custom-fabricated interface, including a single-stage glass jet separator, to a K ratos MS-25 mass spectrometer equipped with a DS-50SM Data System.
Conditions for the Gas Chromatograph. The column was a 50-m WCOT (OV-101) silica capillary column. The carrier gas was hydrogen, at 30 lb head pressure. The column temperature was programmed from 190 to 220eC at 5C/min, hold at 220C for 20 min. The interface temperature was 250s C. Splitless injection was used.
Conditionsfor the Mass Spectrometer. SIM mode was used. (For m/z monitored and details of instrumental procedures see Tables 11 to V.) Ionizing voltage was 70 eV; accelerating voltage was 4 kV.
High-Performance Liquid Chromatography
The apparatus and instrumental parameters applied for HPLC frac tionation of sample extracts are specified below.
MONS 221726
INCINERATION OF PCB 1*5
Parameters for HPLC Fractionation of Sample Extracts
Instrumentation. A Vtri*n Model 5021 Microprocessor Controlled High-Performance Chromatograph was equipped with CDS-1UL Data System.
Parameters. Pressure was maintained between 10 and 250atm. A 25-jil injection loop was used. The guard column was a 37-a# Vydac SC reversephase, 4.0 cm * 0 4 cm i.d. The analytical column comprised two Du Pont Zorbax-ODS columns, each 25.0 cm * 0.6 cm i.d. The temperature of the guard column was 20 C; in the analytical column, 50C. Detectors were: fixed UV, 254 nm, 0.01 absorbent units full scale (AUFS); Varichrom UV-Vis: TCDD, 235 nm, 0.01 AUFS. HxCDD, HpCDD, 245 nm, 0.01 AUFS.
Reagents and Chemicals
The following reagents and chemicals were utilized in the procedures outlined above;
reapeni-grade potassium hydroxide, anhydrous sodium tulfaic and sulfuric acid (J. T. Baker Chemical Co. or Fisher Scientific Co., Fajrlawn, NJ)
diitilled-in-glaai methanol, hexane, methylene chloride and benzene I Burdick and Jackson. Muskegon, Ml)
Omnisolve-quahty, low-boiling petroleum ether (Matheson, Coleman, and Bell, Cincinnati, OH)
Activity Grade I Woclm basic alumina (ICN Pharameeeulicals, Cleveland, OH)
btditu'lled water from all-glass distillation apparatus (Brehm Laboratory) prepunfied nitrogen (Airco, Inc., Montvate, NJ).
Standtrds employed in this work were obtained from the following sources;
l-chlorodibenzo-p-dioxin (Analabs, Inc.. North Haven, CT) 2-chlorodibcnioyvdioxm (Analabs, Inc., North Haven, CT) 2.7-diehlQrodibcnzo-p-dioxin (Analabs, Inc., North Haven, CT) 2^dictilorodibenso-p-<lioaia (Analabs, Inc,. North Haven, CT) 1.2.4-tHchlorodibciuo-p-dioxin (Analabs, fhc,, North Haven, CT) 1.2J,4-tetmchlorodibenxo-p-dioxin (Analabs. Ine., North Haven, CT) "0,*2.3,?,t-TCDD (KOR Isotopes. Cambridge, MA) 2.3.7.S-TCDD and olher TCDD isomers (Dow Chemical Co.. Midland, Ml,
and H. R. Buier, Swiss Federal Research Station, WSdenswi), Switzerland) I.2J.7.S-PCDD (KOR Isotopes. Cambridge. MA) l.2.3.4.7,S'HxCDD (Dr. A, Poland, University of Rochester, NY) 1.2.4,6.7.9-HxCDD (Dr. A. Poland, University of Rochester, NY)
HONS 221729
U4 PCI TREATMENT, RECOVERY AND DESTRUCTION
* TClr 1.2.3.4.6,7,S>HpCDD (KOR Itoiopn, Cambridge, MA) OCDD {Analabi, Inc, Nonh Haven, CD J,CI|*OCDD (KOR Isotopes, Cambridge. MA) 2.4-dichtorodibeniofuran (All CDF obtained from Food and Drug Adminn*
iranon, Wuhinglon, DC) 2.f-diehtorodibemofuran 1,2,4-trichlorodibeniofuran l.2,4.|.ietrachlorodibeniofurin 2.3,T,l,|etrachtorodibeiuofuran 2.2.6.1'teirachlorodibenzofuran l.2,4,7.S-peniachlorodibeniofuran 1,2,3,5,7,9`bcxachtorodibeniofuran I.2J.4,S.I.9>beptachlorodtbeniofuran octachlorodibenxofuran
Quality Assurance
As is the case for all analytical programs conducted in our laboratory, all analytical measurements were accomplished in accordance with good laboratory practice. An extensive quality assurance program is estab lished and followed for all projects such as those described here. This program includes analyses of solvent and method blanks, analyses of internally spiked control samples, and determinations to validate the efficacy of the analytical procedures applied, as already described. Quality control for the individual analyses reported here was also provided on a continuing basis for CDD determinations because of the incorporation of known quantities of labeled TCDD and HpCDD internal 'Undards into each sample before analysis.
RESULTS AND DISCUSSION
Total TCDD and TCDF
Results obtained from the determination of total TCDD and TCDF in the stack effluents (that is, in the individual sampling train samples) from the tests at Rollins are reported in Tables VI and VII, respectively. Corresponding data for the tests at ENSCO are reported in Tables VIII and IX. The data for total TCDD and TCDF are reported separately, because these results were considered by EPA to have greatest relevance for the estimation of health risks in connection with the incineration tests, and were the first results obtained by the Brehm Laboratory in this study.
MONS 221730
Tibk VI. Rnalli *1 Amlfiti ol Rntltiu Incinerator Stack Effluent Stnpln Ih TCDD (TCI Dcaltaetlon Tnh|
Tf mi SimpU Trik
Numbtr
1. *
i. * i, > i. i
1.1 2. 1 2. 1 2. 1 3. 2 3, 2 3. 2 J. 2
TRW SlMpW Number
*03< *0312 6-05IJ *-03*4)60)13* 6-060) 6060* 60607/60MI* *-0609 60643 *4644 6-0643 6-064*
T|ypf
Impinfti* Ptobe waab XAD`2 teem
riorntl
lmpM|crk Ptobe waah XAU-2 rerm Hot tail Impinpcr* Ptobe waah' XAU-2 tetia riot ml
Native TCDD Delected in Entire Sample (n|>
m/i 32* mh 322 Atetap
1 *1 1 *7 I to 3.1* 4)1 314
0 33 2 or 1 31
0 00 000 1.32 1 32 142 000 000 000
000 000
Miahewm Detectable Qoantity
(I)
0 43 0 4J 0 4) 070 0 27 0 27 0.31 041 090
030 0)3
rttcnii Rvc6f(7k
100
too
100 44 7) 120 <07 70 100
0 31
* lUifd an "CIcJJ.M TCDD added at internal atandard `Upper layer (apparently Hexane fraction) only 'Incompletely tetotved interference *1 m/i 122 reiuUr in elevated lifnai. `Compoelle. ' Simple centaincd only one la)er, which appeared 10 be the acetone-water layer, nppet hexane layet observed in other umptci wat completely
a brent
`IN C I vERATIO'1 O f P C I 1*7
HONS 221731
i a PCB TREATMENT, RECOVERV A \D DESTRUCTION
TMr VM Itrnifu nr
nt Itrtlltn, tflftnrutor Slirfc RfflllffM Sampln fnt TCDF (PCI OnttvtlhM Trail)
Tret and Sample Train
Number!
1. 1 t, 1 1, 1 1. 1 2, 1 2. 1 2. 1 2. 1 2, 2 2. 2 3. 2 3. 2
TRW Sample Number
6 0311 6-03(2 6 03(3 *6311/1-0313' 6-0603 6-0606 6460T/6-060I' 6-0609 6 0613 6-0641 6-0643 6-0646
Sample 1 jpe
laitpinpci* Probe with XAP-2 resin 1 lot nd Imptojtr* I'aObe wash X A13-2 ream 1 lonul iMfHftld1 I'robe wash* XAD-2 resin norud
Quantity of Total TCDF
In Entire Semple'
(nt>
33 30 30 0 60 14 20 0 0 0 20 0
Apparent Number of TCDF liomm*
6 T 1 0 * 1 * 0 0 0 1 0
Qoeortly of Apparent
2J,T4-TCOr
mi
07 03 03 0 01 14 0 23 0 0 0 02 0
Minimum Del retable Quantity of
TCDF (all
oot 0 13 0 13 001 01 10 007 OOP 02 03 0t 04
ferteiH Recovery*
100* 100 100
1 T2 121 100 13 100* 60 TJ 30
1 Dull on itinimalHHi of ihe areas of *11 min chiomilogdphac peaks observed ta a selected TCDF letenuon tame window, while monitorani /iXM anal JIM, It li assumed llial the instrument response dctcrmmrd bp Cihbaatrni **h * awheoltc 2.3.T.I-TCDF standard n Ibe tame for ill TCDF
isomers
* 1 be number of discrete min chtoutsloftsphre peaks observed I* (be TCDF window. SmctillTCDF isomers art not ivi liable for dctcvmmilton of
QC iclentlon lima,it is not known whether oi not rich peak represent* more than oaa* nooser. The number etird n therefore the mantmiaai mamber
of TCDF iioostn that can be piescnl to the sample.
* Determined m the bain of the man chtnmato|tapbK peak which has a retention time corrnpondtnf to the! of the 1J.T.l-TCDF nomer Other
1CDF Isomers map also be metuded in tbit peek
`baaed on JICla-J.),T,l-lCDD added H en internal siandard-
* Upper layer (apparemlp bcaane fraction) onlj.
1 Compoetic
`
`Sample conlaincd onlp one layer nhteb appeared to be ibe ncelone-waler layer, apper hexane layer obeetsrd m other samples waa completely
absent,
MO NS 221732
Table VN1. Reaalli n( Auljin n( F.NSCO tnrlneielae Sink EffWent Samplet ( TCOD (PCI Dntrnfllw TnH|
Tnt tnd Simple Train
Mum bet
1, 1* 1. 3 l. 2 l. 2 I. 1
I, 1
2. 1 2. 1 3. 1 1. 1 1, 1
3, 1 3, 1
1 RW StmpU Number
6 0321 6-U539 6-03 W 6-0331 6-0360 6 U36I 6-0362 6-0363 6-03 74A 6-033411 6-03 74C 6-03741) 6-0374E
Swiple T fp*
Piohe with XAIM mm XAIM iciib 1 lofilri lmpm|erc Plot* Wiih XAD-2 tom Por ltd ImfHnjtT* Prohe with X AD-2 mm* 1 totiitlp of 2) riotml (2 of 2}
Mallet TCOD Dflrtled la tnllea Sample
(*>
m/t 321 m/t 321
06IT 0 0M 0 0 0 400 0 0
0 0 0 0 0 0
0 14* 122 0 0 0 3)1 0 0 0
0 0 0 0 0
0 131 0 103 0
0 0 476 0 0 0 0 0 0 0
Mi-Imam Detectable Qaanthy
<!)
062 0062 0 073 0 062 22 23
ojw
0.66 0 '3 0 21 020 020 0 43
Percent Rtevmy"
144 104 13 121
43 ** 134 37 71 * *4 122 46
* Rttid on "CVJJ.P.I-tCUD added at latcrnel HandMd klmpin|tr lempk lrm tlin aetici u htktn (then received by Wiifhl Slale. ' Upper layer (apparently he lane freeucml only *lht olher XA13-2 retia trap -at not leceired by Wnghl Slate.
in c in e r a tio n o f re t u *
MONS 221733
r c * TREATMENT. RECOVERY AND DESTRl CTION
Tibk IX* ftfiu|r of AniJjirt of fi^SCO kwkvrtlw Slieli tfOnmt Somplci foe ICUF (TCI Dniwtlw Toots)
Tm ood Sifli Train
Nowkert
. i* l, 1
1. >
1; 1 1. 1
1. 1 1. 1 21 \t
3.1 )1 31 )1
'
1u w Sample Nionkvr
ft (1311 Milt * 0330 *0331 *0360 *03*1
ftOJftJ ft-374A 4-0374H
*43241) ft 0374E
Simple Typ*
t`inhe noth XAl) } min XAD ] too riot tail InMMtiffi* Ptftht Wuh XAl) 2 Kill Flortul imptoftr1 frohe weak XAD) < namii(ir3) !k>W|141|
OwMiHr of Totol TCDF
it Fn4fcr imph1
<!)
0 10 40 03 13 0 t 0 0
Apparent Nwohee tt TCDF twin*
0 0 4 3 2 3 0 0 0 0 0
QmMM; W
Aftfftiiw u.'4-icur
*>
01 1 12 0J 0 0 0
MWhm Udnlrtk
VwMHr t TCDF
<*1
1 1 01 4 03 004 03 M 03 02 M 04
on
Prevent flreotmj*
30 a
70 100 43 73 ino* 100 100* M0* M0
31 13
* Hiltd on iiiMMiHiii tW it* moi* id iK matt rtwisutogioplMc ptiki obwtved m wlrrtfd T Ct)f teWntion mow mdi* wktk mmimw| mi 9 XU
tod )M If m oioonird 1U1 Ik hhumom iNomw dritrmiod by cslibiMi| *nk on sokWo U.JJJCDr Mnodo*d *1 (he mow for IN ICOF
IMHOMt
k ItwiMfobef *4 duertee ftitumlitraplikhrrod MlkcICDF twdiv fimll TCI)Fwew>HiM n*daMrfordcteMmooiienof
OCrritiHimiipfiwi h i>w hoorna tkikt or so mil pcok rtytowu woo iktaaone noiaut Ike fcombet fiUQtkiriwt kk minimum owoktt
*1 iu>r twmeii nktrk tin be ^hm m ike WMfk
* DtiiMHkrd 00 ike batti of Ike mitt ckcomoiAfflpktt fvok wkrii boo I imeliki lone ttinpw4w| 10 ikM of ike 2,)J,l*TCOF nwm Oifcei
1CLH7 Iwmrii nui oho be wetoded k Ikw prik
4n*wd on
7 I K D|) odded m motmol utodoid
f ImfMffP wrnfdr (root dtn Ktiri vai broke* *kto ictmed by Wtrfkl Slow
1 Uppct kyrr (tpfwtml) kuo ItKlmil okj
1 Ike other XAO-2 rnw nif wot not itriinf by Wrifki S'M<
kHeeo*try <*U ot kv dcitwMoed on kook of low tttdvbw MS Milftn ktinr of windof iMcikiencc m k/t Jit
*
HONS 221734
INCINERATION OF PCI 171
At mentioned etrlier, (he <o(il TCDD results were obtained by LRGC/ HRMS, while (he total TCDF data were obtained by HRGC/LRMS,
As noted above, the results obtained Tor total TCDD do no( permit any definitive conclusions with respect to (he composition of TCDD posi tional isomers. Some information on this topic was obtained however, for TCDD and TCDFfrom capillary-column HRGC/LRMS measurements. These results are discussed below. The data for total TCDD and TCDF shown in Tables VI and VII (Rollins tests) indicate (hat these compounds were detected in the train samples from tests I and 2, but generally were not found in the train samples from test 3. The same observations are applicable to the ENSCO data (Tables Vlll and IX), One possible conclusion that can be drawn from these observations is that the "normal" chlorocarbon wastes incinerated by these two plants are the source of the TCDD (since these were burned in both tests I and 2), whereas incineration of the PCB (which were the only chlorocarbons burned in test 3) did not yield TCDD. There is no obvious rationale for the curious pattern of the TCDD results (for example, the observation of TCDD in the impinger, probe wash and XAD-2 resin samples from one test, whereas only the probe wash sample or the impinger sample contained TCDD in other tests). Possibly, this reflects erratic sampling procedures (as discussed earlier) or variations in the washing of the train components by the field sampling contractor. Alternatively, temperature fluctuations in various sections of the train might account for some of these observations. Similar peculiarities are apparent in the patterns observed for the total TCDF data.
Data for both the TCDD and TCDF are reported as total quantities present in each type of sample analyzed. Since the volumes and weights of the various samples varied considerably, and since these could not be related io original volumes and weights (these were not available, and in any case, leakage and/or loss of unknown quantities of most samples occurred during shipment) it was not possible to calculate concentrations of TCDD and TCDF present in the samples from the analytical data determined by our laboratory.
Isomeric Composition of TCDD and TCDF
Data on the isomeric composition of the TCDD and TCDF present in representative Rollins and ENSCO samples were also obtained in the present study from the HRGC/LRMS measurements. For these latter determinations, a 50-m capillary GC column was utilized, which is capable of resolving many of the tetrachlorinated isomers. For example, Figure 6 shows SIM mass chromatographs obtained for a mixture of 12
MONS 221735
171 PCI TREATMENT, RECOVERY AND DESTRUCTION
Flgurt <. Selected-ion mail chromatograms obtained by HRGC/LRMS Tor 12-Uomer TCDD nandard mixture. Mattes monitored were: * 256-259-. * 319-321: 0 * 327-321, Numbering of peak* corresponds to isomer identification! shown at right.
TCDD isomers by monitoring sequentially nominal m/z 257 and 259 (the sum of these is displayed): nominal m/z 320 and 322 (sum of these is displayed): and nominal m/z 328 in one GC/MS run. Corresponding displays obtained from the HRGC/LRMS analyses of TRW sample number 6-0660 (Rollins test 2, train I, probe wash sample) and sample number 6-0660 (ENSCO test 2, train I, impinger sample) are shown in Figures 7 and 8 (the numbering of peaks corresponds to that shown in Figure 6). By comparing the observed sequence of peaks in these runs with that observed for the standard isomer mixture (Figure 6), and by
MONS 221736
INCINERATION OF PCI I7J
Figur* 7. Selected-ion monitoring maa chromatograms obtained from HRGC/LRMS analysis of Roilint mt 2, train i probe wash sample (TRW No. 6-06061 showing TCDD isomer peaks. Numbering sod symbols art given in Figure 6. '''Cl^ZJJ.S-TCDD was added at an internal standard.
utilizing other related GC data obtained in our laboratory, it is possible to identify positively four of the TCDD isomer peaks detected in the analyses of these two samples. It is known from the results cited above that each of these four isomers is completely resolved from the other 21 TCDD isomers, and identification of these isomen is unequivocal using the experimental conditions employed here. These isomers and their relative quantities (percents of the total TCDD) are listed in Table X for
HOWS 221^37
174 PCI TREATMENT, RECOVERY AND DESTRUCTION
IDO
Flgur* t. Seleeied-ion monitoring mau chromatogram) obtained from HRGC/LRM5 anal)iu of ENSCO ten 2. train l impingcr sample (TRW No. 6-0560) thowingTCDD itomer peak*. Numbering of homer peak* ti given in Figure 6.37Cl-2.3.7.5-TCDD mi added at an internal aundard. Symbol): * * 319-322: # 327-321.
the two samples indicated. Several of the other isomer peaks shown in Figures 7 and 8 also correspond in retention time to specific isomen included in our 12-isomer mixture, but other data obtained in this laboratory indicate that these isomers are not uniquely resolved from the other TCDD isomers, and so the identifications of these other peaks are tentative. Under the presently utilized experimental conditions, the 2,3,7,8-TCDD isomer is also resolved from most other TCDD isomers,
HONS 221738
INCINERATION OF FCB 175
Table X. TCDD liftmen Determined In Stack Effluent Sampln from Incineration Teiti at Roltini and ENSCO
Tcit and Sample Train Numbers
TRW Sampta Number
Orl(ln
TCDD liomeit Delected
Percent of Total TCDD
2. 1
6-0606
Rollini
l +3,6,S-
23
Environmental
1.3,7,9
22
Service)
1.3.6.9
9
1.2.7,9
9
Others*
33
2. 1
6-0360
ENSCO
1.3,6J
20
1.3.7.9
18
1.3.6.9
3
l.2.7,9
3
Others*
54
TCDD are alto observed at retention timet eorrespondtnf to the 1,3.7,*-, 1,2,6,*- and 1,2.6,9- isomers, but thete isomen are apparently not completely retolved from several other TCDD iiomert which could alio account for thete peak*.
*TCDD are alto obterved at retention timet eormpondinf to the 1,3.7.*-, 1.2,6.8- and 1.2,3,*- itomcrt, but thete pcakt may alto be accounted for by teveral other itomcrt.
and since no mass chromatographic peak was detected at the 2,3,7,$TCDD retention time, it is therefore possible to state that, within the limit* of detection applicable here (500 pg) 2,3,7,8-TCDD is not detected in the effluent samples analyzed. It seems probable that the isomeric composition of the TCDD in the other effluent samples would be essentially the same as those detected for the two samples just discussed.
Less definitive data on the isomeric composition of the TCDF could be obtained, because only three TCDF isomer standards were available for calibration (1.2,4,8-, 2,3.6.8- and 2.3,7,8-TCDF), Thus, although a TCDF peak is observed at the retention time corresponding to that of 2,3,7,8TCDF tn the mass chromatograms of many of the samples, completely unequivocal assignment of this peak is not possible at present. The quantities of the TCDF component that is "apparently" 2,3,7,8-TCDF are listed in Tables VII and IX, along with the data for total TCDF. Again, it must be emphasized that this assignment is tentative.
Total Higher-Chlorinated CDD and CDF
Using the complex sequence of HRGC/LRMS procedures described above, the complete series of higher-chlorinated CDD and CDF (total penta- through octachlorinated) were determined in representative Rollins and EN'SCO samples. Examples of mass chromatograms typical
MONS 221739
Intensity
II* M
174 PC* TREATMENT. RECOVERY AND DESTRUCTION
of those obtained in the course of these complete CC/MS scans are shown in Figures 9 and 10. Figure 9 shows the mass chromatograms resulting from injection of a mixture of three TCDF standards. The corresponding mass chromatograms for an actual sample (TRW number 6-0606) showing the responses for various TCDF contained therein are shown in Figure 10. Similar calibration data and corresponding MS data for actual samples were obtained for all the other classes of CDD and
Figure 9. HRGC/LRMS mass ehromaiofram results obtained for calibration standard containing tetraehiondibenaofurans (2.3.7.S-, l.2.4,g- and 2.3.6.S-TCDF). Symbols; * * 303-304. # * 303-306.
HONS 2217*0
1M I--
INCINERATION OF PCI 177
Figure 10. HRGC/LRMS man chromatogram obtained in analyaii of TCDFin Rolllnt leu 2. tratn I probe waiki ample (TRW No. 6*0606. Symbol: f * 303*306.
CDF. The CDD and CDF isomer standards utilized in obtaining the calibration data included:
l-ehlorodiberuo-p-dioxin; 2,7-chlorodibenio-p-dioxin l.2.4*irichlorodibenio*p*dioxin-. 2.3l7.S-ieiraehlorodibenzo*p*dioxin and all 22 TCDD uomen; rCl g*2.3.7.S-ieirachlorod ibeiuo^>>dlox in, 1,2.3,4.7,S*hexachlorodibenzo-^*d)oxin; l,2.3,4.6.7.a*heptachlorodibeiuo*^>dioxin; ociaehtorodibeiuo-p*dioxin:
MONS 221741
ITS PCI TREATMENT. RECOVERY AND DESTRl CTION
2,4-dichlofoUibenzofurzn. l,2.4-mc)ilOfod>benzofurin * 2,J.7,l-telrtehl0rodibnzofurn: * l,2,4.S-tcirachlorodibcnzofuran: * ) 12i4,7.S-perutehlorodibnzofufn: * 1,2.4.6.7.9.hextehlorod'Otnzofurtn; and * ociachlorodiCxnzofuran
The quantities of total CDD and CDF of the various chlorinated classes in iv,-o representative samples [the test 1, train 1, probe wash sample from Rollins (TRW number 6-0582), and the test 2. train I, impinger sample from ENSCO (TRW number 6-0560)] as determined from the HRGC/ LRMS data described above, are listed in Tables XI and XII, respec tively It appears that the quantities of CDF in these samples generally exceed the quantities of the corresponding CDD. The significance of these observations and their bearing on the combustion mechanisms is not apparent, and is difficult to determine in the absence of data on other chemical constituents in the effluents and feed materials.
Polychlorinated Biphenyls
in the limited time permitted for the analyses of samples collected in this survey, it was possible to analyze only a single sample for PCB content. The sample analyzed was a FIorisil trap sample from Rollins test 2, train 1 (TRW number 6-0609), and the results are shown in Table XIII. Typical mass chromatograms obtained for a mixture of PCB standards and for this sample in the course of these analyses are shown in Figures 11 and 12. Similar data were obtained for other classes of PCB. Clearly, several classes of PCB were detected in the sample. The estimated quantities of the various PCB present are given in Table X111.
RESULTS OF RISK ASSESSMENT PERFORMED BY EPA
The data obtained during the course of the complex analyses described above were employed by EPA to accomplish risk assessments for both the ENSCO and Rollins incinerators. The bases for these risk assessments (which estimate the hazards to human health resulting from emissions from these incinerators) are described in detail elsewhere [11], and only the general approach and conclusions derived by EPA are summarized here.
The risk assessment calculations were based solely on the levels of total TCDD and total TCDF provided to EPA by this laboratory [12] and
MONS 221742
INCINERATION OF PCB 17*
Table XI. HHCC/LRMS Data on Total CDD and CDF {Tatra* throu|b OelaeMorinated) In Test I, Train I, Probe Waib Sample (TWR Number t-0512)
from Incineration Teats at Rodina
CDD/CDP
TCDD PCDD HxCDD HpCDD OCDD TCDF PCDF HxCDF HpCDF OCDF
Number of Apparent Isomers*
4 2 1 1 7 6 4 2 1
Quantity of Total CDD/CDF
Detected In Total Sample
(ngl*
4 I 2 5 5 30 25 12 10
Minimum Detectable Quantity
(ng>
03 0.5 2 3 0.2 0.3 0.5 2 3
Percent Recover)*
J00f
I00(
Prefix designations are: T * tetra-; P * penta-: Hx * hexa-; Hp- * hepta: O * octa-. * Since only a limited number of CDD and CDF iiomen are available (tee Tablet 1 and II). it
not pouible to demonstrate for most of the clawet of CDD and CDF that all isomers of a Erven chlorinated (roup {for example, the pcntachlorinaied itomers; there are 14 PCDD) are completely resolved by using the CC condition* employed here. Therefore, it is not ecnain t hat each peak of the family observed for a given chlorinated group corresponds to a tingle isomer. Hence, the terminology `apparent" is used which designated the number of CC peak* observed for a given chlorinated group of CDD and CDF. c Results are corrected for recovery on the basis of recovery of added internal standards. * Recoveries for CDD were estimated on the basis of recovery of two internal standards added to the samples prior to processing These standards are J1Cl4-2J,7.|-TCDD. the recovery of which was assumed to be indicative of the recoveries of native PCDD and lower-chlorinated CDD (that is. mono* through penis-CDD). and ,,CVI.2.J.4.6.7.*. HpCDD. the recovery of which was assumed to be indicative of the recoveries of native HxCDD and higher-chlorinated CDD {that is. hexa- through octa-CDD). No isoiopically labelled CDF were available, and so the recoveries of CDF could not directly be assessed However, recoveries of CDF are probably on the same order as the corresponding CDD. 'Not determined in the HRGC/LRMS analyses, these data were obtained b> LRGC/ HR MS and are reported in Table VII. r Refers to recovery of *'CI-Ubelcd standards mentioned in footnote d.
described here. These dais, in turn, were used in calculating the mass emission rates for TCDD and TCDF during the various test burns conducted at Rollins and ENSCO. To estimate the probable airborne concentrations of TCDD and TCDF that would result from these emissions, a computer modeling scheme was employed. The calculations ultimately yielded an estimate oftheTCDD/TCDF concentrations in the
MONS 221743
)M PC* TREATMENT. RECO' ERY AND DESTRl CTION
Table XII. HRCC/LRMS Data on Total CDD an* CDF (Telra- through Oclachlorinatedl In Tad 2, Train 1. Impinger Sample (TWR Number 4-05*41
from Incineration Testa at EN5C0
CDD/CDF*
TCDD PCDD HxCDD HpCDD OCDD TCDF PCDF HxCDF HpCDF OCDF
Number of Appxrenl Isomers*
Quantity of Totxl CDD/CDF
Detected In Total Sample
34 6 20
MinlmutfT Detectable Quantity
(ngl
1 2 6 1 0.5 1 2 6 1
Percent Recovery
I00f
I00f
* Prefix dcugnationt art. T * teira*. P * pcnia-; Hx 1 hexa*. Hp* * hepta. O * ocu*. * Since only a limited number of CDD and CDF iiomcrt are available (tee Table* 1 and II), it
it not ponible to demonstrate for most of the classes of CDD and CDF that all iiomcrt of a given chlorinated group (for example, the pentachlonnaicd iiomcrt; there are 14 PCDD) are completely rctolved by using the CC conditions employed here. Therefore, it it not certain that each peak of the family observed for a given chlorinated group corresponds to a tingle isomer. Hence, the terminology `apparent' it used which designated the number of CC peaks observed for a given chlorinated group of CDD and CDF. (Results are corrected for recovery on the basts of recovery of added internal standards. * Recoveries for CDD were estimated on the basis of recovery of two internal standards added to the samples prior to processing. These standards are ^Cle-ZJ.T.I-TCDD, the recovery of which was assumed to be indicative of the recoveries of native PCDD and lower-chlorinaied CDD (that is. mono- through perns-CDD). and ^CV 1.2.3,4 HpCDD. the recovery of which was assumed to be indicative of the recoveries of native HxCDD and highcr-chlonnaied CDD (that is. hexa- through octa*CDD). No isotopically labelled CDF were available, and so the recoveries of CDF could not directly be issessed. However, recoveries of CDF arc probably on the same order as the corresponding CDD. 'Not determined in the HRGC/LRMS analytes; these data were obtained by LRGC/ HR MS and are reported in Table VII, 1 Refers to recovery of ^CMabelcd standards mentioned in footnote d.
breathing zone* of persons living netr the incinerators. From the latter results, by utilizing a number of "worst case' assumptions, and by taking into account the risk factor associated with breathing air containing 2.3.7,8-TCDD [13,14], EPA concluded that the risk of additional cancers in the population exposed to the emissions from the ENSCO incinerator ranges from I to 4 in 10,000,000. Similarly, the risk of additional cancers
MONS 221744
INCINERATION OF PC* III
Tabla Xlll. HRCC/LRMS Data on PC* In Teat 3, Train I, Florlal Sample
(TRW Number
from Incineration Teal al Rollins
Class of Chlorinated PCI (No. of Chlorina Subtil tutnisl
Monochlonnated (1) Dichlortruicd (2) Trichlori ntted (3) Tciraehlonnaicd (4> Pcmachlonnated-
Dreaehlonnticd (3-101
Number of Apparent Isomers*
3 1 4
Quantity of PCB Detected In Total Sample
<ng>*
10 IS 3
C
Minimum Detectable Quantity
("gl
0.1
0.3 0.3 OS
* On]) a limned number of PC* a omen arc avertable for uit in establishing GC retention lime* and sensitivities for PCB, and 10 it eould not be demonitraicd that all isomer* of a given ehlormaicd elan art resolved mint the GC condition* employed here. Therefore, it i* not certain that each peak of the family observed for a given chlorinated group correspond* to a single tsomcr. Hence, the terminology "apparent" is used, which designates the number of GC peaks observed for a given chlorinated group of PC*.
* Assumes that the lensittvines of all isomers of a given ehlorinated class are ihc same. These data are not corrected for recovery, since no isotopwally labelled PCB were available to establish recoveries for the method used.
* Some ClyClia PCB art probably present, but there were loo many interfernng MS peaks
to reliably determine these.
in the population exposed to the emissions from the Rollins incinerator was estimated to range from 1 to 180 in 10,000,000. EPA .ruled that these risks were negligible and therefore, in early 1981, granted approval for the ENSCO and Rollins plants to continue incineration of high-level PCB wastes.
It is concluded from this assessment, therefore, that under proper conditions, incineration is a viable procedure for destruction of PCB wastes.
ACKNOWLEDGMENT
The work described here which was conducted by the Brehm Labora tory of Wright State University was supported by the U.S. Environmental Protection Agency under Cooperative Agreement No. CR806846-01.
MONS 221745
H tta li* * In te n s ity
111 FCB TREATMENT. RECOVERY AND DESTRUCTION
Fijurt 11. Selected-ion men ehromatogrami obtained from HRGC/LRMS anatviti of a mixiurt of mono-, di-, tri- and ictrachlonniied PCB ttandard*. Symbol*: * * IM-192; V * 222*225; 0 * 255*251; It * 219*292. See Table V for iittinf of turner maitei corresponding to each PCB elau.
HONS 221746
1M-
INCINERATION OF FCi 1*3
MUU InltA iU f
Fijurt 12. Selected-ion maw chromatograms obiamcd from HRGC* LRMS analysis of EN'SCO teat 2. tram 1 Floruil sample (TRW No. 6^>M9) for tetnchlormatcd PCB,
HONS 221747
114 PCI TREATMENT, RECOVERY AND DESTRUCTION
REFERENCES
1. Ftderal Refiner 44:31514 (1979). 2 Wasserman. M . D. Wasserman. S Cue os and H. J, Miller. Ann. N. Y. Acad.
Set. 320:69 (1979). 3. Buser, H. R., H. P. Bosshardt and C. Rappe. Chcmosphere 7.109 (1978). 4. Poland, A., W, F. Greenlee and A S. Kende. Ann. S. Y. Acad. Sri. 320. 214
(1979). 5. McNulty, W. P., D. Becker and H. T. Cor)'. Toxicol. App. Pharmacol. 56:182
(1980). 6. Tiernan. T. O., J. H. Garreu, G. F VanNess, J. G. Solch and M. L. Taylor. In
preparation. 7. Moore, D R., R. W, Korner, W, F. Wright and D. G. Ackerman. "Plan for
Emissions Telling at Two Commercial Incinerators: Rollins Environmental Services, Jnc,, Deer Park, Texas, and Energy Systems Company, El Dorado, Arkansas," prepared for Industrial Environmental Research Laboratory, U.S. EPA, Research Triangle Park, NC, Contract No. 68-02-3174 (1980). 8. Tiernan, T. O., M. L Taylor. J. G. Solch, G. F. Van Ness and J. H. Garrett. "Determination of Polychlorinated Dibenxodioxms tn Incinerator Effluents," prepared for U.S. EPA, Environmental Sciences Research Laboratory, Re* search Triangle Park, NC, Order No. D2832 NAEX (1980). 9. Bumb, R. R,, W. B. Crummett, S. S. Cutie, J. R. Gledhill, R. A. Hummel, R. O. Kagel, L L Lamparski, E. V. Luoma, D. L. Miller. T. J. Nestrick, L. A. Shadoff, R. H. Stehl and J. S. Woods. "Trace Chemistries of Fire; A Source of Chlorinated Dioxins," Science 210:385 (1980). 10. Lamparski, 1_ I_, and T. J. Nestrick. Anal. Chem. 52:2045 (1980). 11. Barnes, D. G. "Considerations of Risks and Benefits/ Alternatives Concern ing PCB Incineration in Region VI,"Draft IV, U.S, EPA, Office of Pesticides and Toxic Substances, Washington, DC (1981). 12. Tiernan, T. 0., J. G. Solch, G. F. VanNess, J. H. Garrett, M. Porter and M. L. Taylor. "Determination of Polychlorinated Dibenzo-jvdioxtns (PCDDs), Dibcniofurans (PCDFs). and Biphenyls (PCBs) in Stack Effluents and Other Samples Resulting From Assessments of PCB Incineration Tests at Rollins Environmental Services, Deer Park, Texas, and Energy Systems Company (ENSCO). El Dorado, Arkansas," Interim Report. Brehm Laboratory, Wnglu State University, Dayton, OH. U.S. EPA Cooperative Agreement ?CR 806846 (1981). 13. Cancer Assessment Group. "Risk Assessments on 2,4.5-T, Silvex and TCDD," U.S. EPA, Washington. DC (I960). 14. Cancer Assessment Group. "Unit Risk Assessment on TCDD in Air," U.S, EPA, Washington, DC (1980).
MONS 221748
CHAPTER 10
ULTIMATE DISPOSAL OF POLYCHLORINATED BIPHENYLS
T. C- Barton Department of Civil Engineering Royal Military College or Canada Kingston, Ontario K7L 2W3
C. P, Ancnaull Department of Chemistry and Chemical Engineering Royal Military College of Canada Kingston, Ontario K7L 2W3
Polychlorinated biphenyls (PCB) present a difficult problem for con ventional waste disposal systems. They are very stable chlorinated organic molecules that require long dwell times at high temperatures to effect thermal destruction. Present incineration guidelines suggest a 2.0-sec dwell at 1200*C or a 1.5-sec dwell at I600C. These combinations are difficult to achieve in incinerators, yet can be easily achieved in a plasma system. However, these guidelines may be extremely conservative for a plasma system, for two reasons. First, since radiative heat transfer proceeds as a function of the fourth power of the temperature differential, a plasma system is capable of transferring energy approximately six million times faster than conventional incineration. Second, organic chlorides are known to dehalogenate when excited by ultraviolet (UV) light It thus may be conceived that a plasma system possesses properties conducive to ultimate destruction of organic halogens such as PCB. A test was conducted to qualify this belief, and a further 5400,000 test program,
185
HONS 221749
IM RCB TREATMENT. RECOVERY AND DESTRUCTION
funded by the Ministry of the Environment of the Province of Ontario, is presently under way for toxic waste destruction at the Royal Military College in Kingston, Ontario.
PCB COMPOSITION AND USES
PCB is the name given to a series of aromatic organochlorine homologs and isomers having the chemical composition C|2Hio.aCln. PCB is a double benzene ring linked by a C-C bond and having 10 possible chlorine substitutions per molecule. Theoretically, this configuration results in 210 PCB isomen, having low water solubilities, low volatilities, and a high degree of resistance to chemical and thermal degradation. In general, solubility and volatility decreases with increasing chlorine substi tution, whereas resistance to breakdown increases. A further important property of PCB is high solubility in organic solvents. The chemical stability of PCB coupled with excellent electrical insulating capabilities led to extensive use as dielectric fluids in capaciton and transformen. PCB were also used as hydraulic and heat transfer fluids, as wax and pesticide extenders, in carbonless reproduction paper and in other minor applications. Since the discovery of the toxic effects of PCB, their use has been limited to closed systems where release into the environment is minimal.
Commercial production of PCB started in 1929,48 yean after the tint reported chemical synthesis of these compounds [I]. In North America, the sole producer was Monsanto, which supplied 99% of U.S. and Canadian requirements. Monsanto marketed a range of PCB products, trademarked Aroclor, which contained varying mixtures of chlorohomologs. For example, Aroclor* 1254, which has an average chlorine content of 54%, contains four homologs in varying amounts.
Total U.S. production to date has been estimated at 1.45 billion pounds, reaching an annual high of 85 million pounds in 1970. Mon santo's voluntary' ban on production for open system usage in 1970-197) reduced annual production to 40 million pounds. Production ceased in 1977. Canadian imports have been estimated at 75 million pounds plus an unknown amount imported in the form of finished electrical goods [2],
PCB IN THE ENVIRONMENT
PCB are ubiquitous in the environment. They have been found in ocean sediments, the atmosphere, and a large number of terrestrial and aquatic
MONS 221750
ULTIMATE DISPOSAL OF PC 117
locations, including both polar icecaps. Of local concern is the Great Lakes ecosystem, which contains among the highest recorded ambient PCB levels. For example, in Lake Ontario, the water has a measured concentration of 45 ppt, the sediment has 72 ppb and certain fish more than 2.5 ppm. Ontario citizens have the highest PCB residues in Canada: males have 1.125 ppm and females, 0,859 ppm in adipose tissue [3].
The major routes of PCB into the environment are leaks from sealed or partly sealed systems, spills and losses during manufacture, vaporization or leaching from PCB-containing formulations, and disposal of waste PCB [4], The presence of PCB in the atmosphere and in areas remote from heavily industrialized locations indicates that atmospheric transport is the major route of global dispersion. In large ecosystems, PCB input from atmospheric deposition is the greatest source of contamination, exceeding point sources such as sewage treatment plants and industrial sites [5-7].
In an aquatic environment, PCB spread through me water column from the air-water interface to the bottom sediment. Aquatic fauna accumulate PCB through equilibrium partitioning and food sources, the latter predominating in higher trophic levels. Because of the chemical inertness and resistance of PCB to metabolism, magnification within the food chain has been observed. Predatory fish have the highest concen tration factors, about 10*. Concentration factors for water, sediment, and plankton in Lake Ontario are 1:2500:10* [8*11]. The principal source of PCB uptake in humans is the diet [12]. Although fish provide the greatest input, PCB have been found in small concentrations in poultry, meat, produce, dairy products, food wrapping and other household articles [13].
PCB are truly pervasive in the environment and will remain so for a long period of lime. Temporal trends show no discemable evidence of a decrease in ambient PCB concentrations, despite the Monsanto ban.
TOXICOLOGY OF PCB
PCB are not particularly toxic in acute or short-term testing. Very high dosages are necessary to induce a lethal response in most trophic levels. However, chronic exposure to sublcthal concentrations combined with high lipid solubility and resistance to metabolism can result in PCB accumulation and a toxic response. Synergistic effects of other con taminants and environmental stresses are not fully understood, but they may intensify the toxic effects of PCB.
In zooplankton and marine algae, PCB in 10-ppb concentration have
HONS 221751
1M PCB TREATMENT, RECOVERY AND DESTRUCTION
been observed to alter community growth rates by as much as 80%. Growth of algae greater than 8 ^m was inhibited by an order of magnitude, changing the population distribution. The community had not fully recovered after 10 days in a PCB-free environment [14-18].
Higher forms of aquatic life also showed toxic responses. Concentra tions of 10 jjg/1 caused decreased shell growth in oysters and higher mortality rates in shrimp and several types of fish. Reproductive success of Atlantic salmon and rainbow trout has been affected adversely by high PCB residues in eggs. Pathological repsonses to sublethal dosages of PCB were found in livers, kidneys and spleens of experimental fish.
Birds have also been studied widely to determine the effects of PCB poisoning. Species reproductive success has declined as a result of eggshell thinning. PCB are but one of several organochlorine substances, such as DDT and Mirex, that are implicated. Highest body residues are found among raptors and birds whose chief source of food is fish [II],
In Japan, a PCB poisoning incident known as "yusho" provided information on the effects of PCB to humans. Rice oil, contaminated with 1000 ppm PCB, was ingested by about 1200 people. Total body burdens were about 2 g, resulting in PCB concentrations of up to 75 ppm in subcutaneous fat. Patients complained of constant abdominal pain, poor appetite and general fatigue. External symptoms of poisoning were acneform eruption, pigmentation, swelling of eyelids, eye discharge and deformation of nails. The principal organs affected w'ere the liver and skin m
There is a small body of evidence to link PCB with carcinogenesis. Rats developed benign lesions in the livers and experienced an increase in the numbe; of cells in the liver whereby the bulk of the organ was increased. These reactions are similar to effects of knowm hepatocarcmogens prior to the appearance of carcinoma. Among yusho patients, 9 of 22 deaths in subsequent years were caused by malignant neoplasms, suggesting a possible excess of deaths from cancer [11,19].
LEGISLATION AND DISPOSAL
As a result of a recommendation by the Organization for Economic Cooperation and Development (OECD), and after many national studies, many countries imposed restrictions on PCB use and disposal. In Canada, this responsibility is divided among the various levels of government. The Canadian government has issued guidelines on storage, handling and disposal of PCB, although no disposal technology is in place. These guidelines permit release of PCB to the environment in low
HONS 221752
ULTIMATE DISPOSAL OF PC* 119
concentrations such as road oiling with oil contaminated with less than 25 ppm of PCB [20]. Such guidelines will only increase the environmental burden of PCB and may encourage dilution as a solution to the present toxic waste storage problems.
Approximately 450,000 kg of PCB plus an unknown amount of contaminated solids are presently awaiting ultimate disposal in Canada. Ontario, with 91% of this total, has no licensed disposal site. With disposal stockpiles growing at an annua) rate of 500,000 kg, it is clear that an effective method of disposal is urgently required.
PLASMA ARC TECHNOLOGY
Plasmas have been referred to as the fourth state of matter, because they do not always behave as either a solid, liquid or gas. A plasma may be defined as a gas consisting of charged and neutral particles, having an overall charge of approximately zero, which exhibits collective behavior [21,22], Within the universe, as much as 99% of matter, including stars and interstellar space, is in the plasma state [23], On earth, plasmas are much less prevalent, but the aurora borealis, lightning bolts, fluorescent and neon lights, and arc welding are common examples. They all exhibit a common property of plasmas, an ability to readily conduct electricity.
Electrical arcs are used in day-to-day applications in arc welding. Arc welders are characterized by very short arcs and by electrodes that are quickly destroyed by the process. To create longer arcs, an innovation was required to increase the stability of the discharge at the higher voltages. Initially, the plasma arcs destroyed themselves in a matter of minutes. Subsequent developments have led to plasma arcs that do not destroy the electrode, while producing a transferred plasma are with excellent dimensional stability. Arcs in general require a great deal of maintenance, primarily because they are uncontrollable at elevated voltages, and therefore require huge amounts of current to develop large amounts of power. The development of a marketable plasma torch was undertaken to reverse the higlv<urrtnt/low-voltage requirement. The torch at tha royal Military College Plasma Arc Research Facility demonstrates very clearly the success of that effort. Plasma systems no longer need to destroy themselves and require only very little maintenance.
The plasma arc can best be understood by thinking of it as an energy conversion and transfer device. A low-pressure gas is used as the medium through which an electrical current is passed. The type of gas used is relatively unimportant in creating the discharge, but will affect the
MOWS 221753
m PCI TREATMEM, RECOVERY AND DESTRUCTION
ultimate products formed. In passing through the gas, electrical energy is converted to thermal energy by absorption by the gas molecules. The gat molecules are activated into ionized atomic states with equivalent temper atures of about 50,000* K. In relaxing from these activated states, radia tion is given off for absorption by material fed into the plasma.
As a result of energy absorption, waste feed materials are atomized and ionized as they interact with the decaying plasma species. This process is one of molecular fracture rather than a chemical oxidation reaction typical of incineration. The products that result are simple because the activated states are atomic. This reflects the much more energetic nature of the radiation supplied by the plasma discharge compared to the oxidation processes involved in combustion. Furthermore, the volume of gaseous products is much less than the volume produced in combustion and thus greatly reduces the scale of commercial equipment. Figure I shows the reaction vessel, the liquid feeding apparatus and the product gas scrubbing system presently being used for plasma pyrolysis of liquid waste material.
Fitort 1. Rctcuon vessel system.
HONS 221754
ultimate disposal of rc 1*1
The reaction vessel is fabricated from stainless steel and is refractory* lined to limit heat loss to less than 10% of the applied power. The plasma torch, which is inserted through the top of the vessel, is rated from 60 to 350 kW and is water*cooled to prevent torch destruction. The gas scrubbing system consists of a water-injected venturi scrubber, a wet cyclone and a scrubbing water reservoir as shown in the schematic of the system in Figure 2.
Water from the scrubber reservoir is injected into the venturi at a rate of 15 liter/sec to quench hot product gas from 900*C down to 50C, and to wet carbon soot entrained in the product gas stream. The wetted gas then passes through the cylcone, where > 99% of the water is extracted from the product gas. The extracted water is returned to the 200-liier scrubber reservoir, where it is cooled before being recirculated through the scrubbing system. The entire product gas stream then passes through the glass impinger network, which is designed for a gasflow approaching 40 liter/sec. The impinger network is chilled with ethylene glycol and dry ice to promote exceptional trapping of organic species produced during pyrolysis of liquid wastes. The impinger network is shown in Figure 3.
An integral part of the application of this plasma are technology is the computerized pyrolytic simulation model based on kinetic equilibrium. If plasma forces rapid atomization of organic compounds injected into the
PLASMA REACTOR
CYCLONE
IMPlNGEAS
Figure 1. Schematic of PCB tell equipment.
HONS 221755
l PCI TREATMENT. RECOVERY AND DESTRUCTION
Fifur* 3. Itnpmftr network.
plasma, then recombination: of new molecules from the aiomic specier formed shouio be predictable rased on kinetic equilibrium. The computer model is used to predict the composition of products formed from waste feedstocks and the amount of plasma energy required to effect pyrolysis. Equilibrium and material balance equations are used to determine the concentrations of product species formed over a range of equilibrium temperature for selected operating conditions. Changes in enthalpy between the feedstock and the output products are used to predict the quantity of plasma energy required adiabatically for the pyrolysis of organic matter. This approach to predicting the performance of the plasma pyrolysis process has been tested and supported with experi mental data which is published elsewhere [241, This computer simulation is used to determine suitable test conditions.
MOMS 221756
LLTIMATE DISPOSAL OF PCI l
INITIAL PCB TESTING
The first test was conducted to demonstrate qualitatively the destruc tion of a 27.000-ppm concentration of PCB in toluene [25]. During the test, 1.6% of the product gas was continuously drawn through a dual ethylene glvcol impinger system, with a rated capture efficiency of 99.6%. The gas was also monitored by an infrared f!R) analyzer for methane, carbon dioxide and carbon monoxide concentrations. Subsequently, PCB analysis by gas chromatography (GC) was carried out on the impinger liquids
A Miran 80 single-beam infrared spectrophotometer was used for quantitative analysis of the product gas for CO, CO; and CH. The gas flowed continuously through the 1-cm cell at 8 liier/min, with analyses performed at I-min intervals. Each wavelength was scanned approxi mately 15 times during each analysis. An Intel 8080A microprocessor then applied Beer's law to the measured absorbances and the absorbance constants stored in memory to calculate the concentration of each component.
A Vartan Aerograph Model 920 gas chromatograph equipped with a thermal conductivity detector was used for analysis of impinger fluid for PCB presence. The helium carrier gas flowed at a rate of 90 ml/min, through the I3*ft * 1 /4-in. copper chromatographic column packed with 5% S.E. 30 on Chromosorb P. The isothermal temperature settings were 295 C for the injector, 265 C for the column and 310C for the detector. A filament current of 180 mA was used in the thermal conductivity detector.
An Askarel sample consisting of Aroclor 1254 and trichlorobenzene in the ratio of 68 2% (as analyzed by the Ontario Research Foundation) was used to determine the characteristic chromatogram of the Aroclor 1254 and the limits of detection. From a standard solution of 68 mg in 5 ml of spectranalyzed hexane, five IO-*il and three 1.0-ul samples of solution were analyzed. The effective lower limit of detection was judged to be 10 jug of Aroclor 1254.
A typical chromatogram of a 10-/j1 injection is shown in Figure 4, and a chromatogram of the extracted impinger residue is shown in Figure 5.
Assuming the worst case, that the gas chromatograph results represent PCB only, integration of the curve showed that no more than 10 mg of PCB were collected in the impingers. The destruction efficiency is conservatively estimated to be greater than 99% from this qualitative test. A comparison of the two chromatograms presented clearly shows the conservative nature of the claim made to the destruction of the Aroclor 1254.
HONS 221757
If4 PC TREATMENT. RECOVERY and destrvctjov
Figure 4. Chrr>m*iojrm of 10 pi Aroclor 1254.
Although this test was qualitative in nature, it yielded a number of significant observations. The results indicated that the plasma torch was capable of destroying PCB with a high degree of efficiency. It was evident that the principal limitation to the determination of the destruction efficiency was the efficacy of the sampling and analysis procedures
MOMS 22i758
ULTIMATE DISPOSAL OF PCI tW
and not the plasma torch. Specifically, the sampling and analysis phase did not incorporate 100% offgas testing, the identities of the organic com pounds in the GC scan were unknown and the impinger did not ensure 100% PCB collection. The adiabatic plasma energy required for pyrolysis was less than 0.6 kWh/kg of solution and represents only about 10% of the fuel value of this waste feedstock.
To improve the analytical results, several steps are necessary. Since these results are based on one test, more tests are obviously required to ensure repeatability. High resolution and high sensitivity will require a gas chromatograph with a better detector, such as an electron capture detector (ECD). A gas chromatography/mass spectrometry/computer (GC/MS/COMP) system will be necessary to identify the extraction residue, assuming it is not PCB. With the financial assistance of the Ontario Ministry of the Environment, we have begun a comprehensive testing program.
COMPREHENSIVE TESTING PROGRAM
A series of tests has been conducted using ethanol, methanol and methanol with trichlorobenzene as liquid wastes. The purpose of these tests was to demonstrate the performance of the plasma system and to esublish the degree to which energy and material balances could be determined. These feedstocks were used as precursors to future PCB tests to minimize any pollution dangers. Computer simulations based on waste atomization and kinetic equilibrium reformations were conducted before each test to establish suitable test conditions.
Although many chlorinated organic destruction demonstrations have shown a reduction in concentration of the waste of interest in the test effluent, few have been able to identify the location of the chlorine and complete a chlorine balance (even on a macroscopic basis). If a chlorine balance can be demonstrated, the perceived dangers of producing large quantities of other harmful organic chlorides during the destruction of PCB compounds are greatly minimized. Rather than using PCB to attempt a complete chlorine balance, mimicking ring-structured com pounds such as chlorobenzenes can be used to test the ability of the experimental apparatus to capture chlorine compounds.
MOMS 221759
)H PCI TREATMENT, RECOVERY AND DESTRUCTION
According to computer simulations of the destruction of a solution of trichlorobenzene in methanol (500 g in 3 liters) virtually all the chlorine should form hydrogen chloride. Minor amounts of other chlorine com* pounds formed should be present in concentrations of less than 5 ppm. If the computer model is accurate, hydrogen chloride would be found in the scrubbing water reservoir and the trace amounts of other chlorinated compounds should be isolated in the impinger network.
Changes in the pH of the scrubber reservoir during the test sequence were used to estimate the extraction of hydrogen chloride from the product gas. Obviously, unless some neutralization of the pH in the reservoir is simultaneously carried out, the rate of hydrogen chloride removal in the venturi will diminish as the pH of the scrubbing water drops. Nevertheless, the initial rate of pH change can be used to predict the rate at which hydrogen chloride is captured in the venturi, and can be compared to the theoretical production rate to determine the efficiency of the scrubbing. Additional tests with neutralization of the hydrogen chloride eliminated carbonic acid interference, which is prevalent at high pH values, and provided total chlorine mass information.
For the tests using trichlorobenzene in methanol, where no neutrali zation is carried out, the initial rate of change of pH showed that the venturi scrubber mechanism was better than 98% effective in extracting the hydrogen chloride. Without neutralization and based on total change in pH, approximately 70% of the chlorine could be accounted for in the scrubber reservoir. However, with neutralization, using sodium hydrox ide, more than 96% of the mass of chlorine could be accounted for in the scrubbing water. It is believed that problems with scrubbing water pumps and reduced fluid flows during the last minutes of these tests are respon sible for allowing the escape of a minor amount of hydrogen chloride during these tests. Neutralization was carried out so as to maintain only slightly acidic conditions in the scrubbing reservoir to minimize inter ference from carbonic acid.
Trace analyses for trichlorobenzene in the scrubbing water reservoir showed a presence of less than 0.00013 of the mass of trichlorobenzene fed to the system during each test. It is perceived that this material enters the scrubbing system as a result of the shutdown procedure rather than short-circuiting of the waste during the test. Impinger residue analyses showed no confirmed presence of trichlorobenzene based on GC.'ECD findings. However, if the area under the chromatogram spanning the theoretical location of trichlorobenzene is used as an indicator of the residue, less than 0.0001 of the material survived the plasma system. This
MOWS 221760
t'LTIMATE DISPOSAL. OF PCS 1*7
gives a destruction efficiency greater than 99.99%. The estimate of the impinger residue presently is believed to be high by several orders of magnitude.
More than 80% of the energy injected into the system can be accounted for by direct measurement. The remaining 20% cannot be practically measured, but is consistently accounted for by wall losses from the test system and energy added to the thermal mass of the system. The energy balance calculations support the theoretical change in enthalpy predicted for the feedstocks by the computer simulation.
The 12 chlorobenzenes were selected as mimicking compounds because they have a wide range of solubilities and vapor pressures and can be mixed to give elemental compositions identical to commercial PCB. Two of the three trichlorobenzenes are also present in the Aroclors. Chromato graphic separation of the 12 chlorobenzenes is easily accomplished using capillary column GC, and their quantification is easily possible. Thus, materia) balances and destruction efficiencies could be readily determined while minimizing the risk of social displeasure associated with this work.
During each test, a combination of 4- and 9-in.-diameter impingers was used. Internal calibration to determine impinger trapping efficiency was conducted during each test by injecting known amounts of monobromobenzene. The larger impingers were packed with 20-mm Raschig rings and contained 500 ml of ethylene glycol as a wetting agent. At the end of each test, each impinger was injected with a known quantity of orthodibromobenzene to be used as an indicator of the effectiveness of the extraction procedure. Extraction efficiency was better than 99%, and impinger trapping efficiency was comparable. Additional work is now underway to improve material balances and determination of destruction efficiencies with PCB testing commencing in fall 1981.
REFERENCES
1. "PCBs in the United States: Industrial Uses and Environmental Distribu tion," U.S. EPA Report 560/6-76-005 (1976).
2. Montciih, J. R. "The Nature and Magnitude of the PCB Problem,' Proceedings of the Hazardous Waste Management Seminar, Toronto, Ontario, October 26-28, 1978.
HONS 221761
m PCI TREATMENT. RECOVERY AND DESTRUCTION
3. Grant, D. L. J. Me* and R. Frank. "PCB Residue* in Human Adipose Tissue
and Milk," Proceed in p of the National Conference on Polychlorinated
Biphenyls, Chicago, 1L, November 19-21, 1973, U.S. EPA Report S60/6-7S-
004.
4. Nisbet, 1. C. 1. "Environmental Transport and Occurrence of PCBs in 1973,"
m Proceeding* of the National Conference on Polychlorinated Biphenvls,
Chicago, !L. November 19-21, 1975, U.S. EPA 560/6-75-004.
'
5. Shannon, E. E., F. J. Ludwig and 1. Waldmoni*. "Polychlorinated Biphenyls
in Municipal Watte Waters," EPA Project No. 73-3-8 (1976).
6 Ware, D. M., and R. F. Addison. "PCB Residues in Plankton from the Gulf
of St. Lawrence," Nature 246.519-521 (1973).
7. Furness, R., and M. Hutton. "Pollutant Levels in the Great Skua, Environ.
Poll, 19:261-268 (1979).
8. Clayton, J. R., Jr., S. P. Pavlou and N. F. Breitner. "Polychlorinated
Biphenyls in Coastal Marine Zooplankton: Bio accumulation and Equilib
rium Partitioning," Environ. Sci. Technol, 11:676-682 (1977).
9. Nimmo, D. R., P. D. Wilson, R. R. Blackman and A. J. Wilson. "Polychlo
rinated Biphenyl Absorbed from Sediments by Fiddler Crabs and Pink
Shrimp," Nature 231:50-52 (1971).
10, Vrecland, V. "Uptake of Chlorobiphenyl by Oysters," Environ. Poll,
6:135-140 (1974).
1), Roberta, J. R.. D. W, Rodgers, J, R, Bailey and M. A. Rorke. "Polychlo
rinated Biphenyls: Biological Criteria for An Assessment of Their Effects on
Environmental Quality," National Research Council, NRCC-Repon 16077,
(1978).
12. Jelinek, C. F., and P. E Corneliussen. "Levels of PCBs in the U.S. Food
Supply," in Proceedings of the national Conference on Polychlorinated
Biphenyl, Chicago, 1L, November 19-21, 1975, U.S. EPA Report 560/6
73-004.
13. Villeneuve, D. C., L. M. Reynolds and G. H. Thomas. "Polychlorinated
Terphenvts in Canadian Food Packaging Materials," J. Assoc. Off, Anal
Chem. 56:999-1001 (1973).
14. Biggs, D. C.. R. G. Rowland, J. B. Connors, C. D. Powers and C- F. Wurster.
"A Comparison of the Effects of Chlordane and PCB on Growth. Photosyn
thesis and Cell Size of Estuarine Phytoplankton," Environ. Poll, 15.254-263
(1978).
'
15. Fisher, M. S., L. B. Graham, E. J. Carpenter and C. F. Wurster. "Geo
graphical Differences in Phytoplankton Sensitivity to PCBs," Nature
241:548-549 (1973).
16. Fisher, N. S. "Chlorinated Hydrocarbon Pollutants and Photosynthesis of
Marine Phytoplankton: A Reassessment," Science 189:463-464 "(1975).
17. Moore, S. A., and R, C Harris. "Effects of Polychlorinated Biphenyls on
Marine Phytoplankton Communities." Nature 240:356-358 (1972).
18. Masscr, J. L., M. S. Fisher, T -C. Teng and C. F. Wurster. "Polychlorinated
Biphenyls: Toxicology to Certain Phytoplankters," Science 75:50-52 (1972).
19. Kuratsune, J., Y. Masuda and J. Nagayama. "Some Recent Findings
Concerning Yusha," in Proceedings of the National Conference on Poly-
ehlorinaied Biphenyls, Chicago, IL, November 19-21, 1975, U.S. EPA
Report 560/6-75-004.
MOMS 221762
ULTIMATE DISPOSAL OF PCB t 20. Pheonix, R. Proceedings of the Hazardous Waite Management Seminar,
Toronto, Ontario, October 26-28. 1978. 21. Chen, F. F. Introduction to Plasma Physics, (New York: Plenum Publishing
Corporation. 1974 ) 22. Hellund. E. J. The Plasma State, (New York. Rheinhold Publishing Corpora
tion, 19611. 23. Frank-Kamenetskii, D. A Plasma: Tht Fourth State of Matter, Joseph
Norwood, Jr,, Trans. (New York: Plenum Publishing Corpiration, 1972). 24. Barton, T. G. `An introduction to Waste Disposal by Plasma Arc Heating,"
Royal Military College of Canada, Civil Engineer Research Report No. CE 60*1, Kingston, Ontario (March 1980), 23. Dobion. R. L. "Destruction of Polychlorinated Biphenyl by Plasma Arc Pyrolysis," MEng Thesis, Royal Military College of Canada, Kingston, Ontario (1980).
HOMS 221763
CHAPTER 11
CHEMICAL DESTRUCTION OF POLYCHLORINATED BIPHENYLS IN
TRANSFORMER OIL
John F. Brown, Jr., Marie E. Lynch end Jamal C. Carnahan General Electric Rcteareh and Development Center Schenectady. New York 1230)
Jerome Singleton General Electric Apparatus Service Shop Philadelphia, Pennsylvania 19124
One consequence of the restrictions on the use of polychlorinated biphenyls (PCB) enacted into law by Congress in 1976 and subsequently promulgated into regulation by the U.S. Environmental Protection Agency (EPA) has been to create a need for nearly total removal of tracelevel PCB from some still uncertain fraction of the 1.3 billion gallons of specially refined mineral oil (10C oil) currently in use in U.S. trans formers. A known generic approach to selective destruction of aromatic chlorides like PCB in hydrocarbon media at low temperatures consists of treatment with reactive anion radicals, formed by interaction of sodium metal with an electron carrier in an aprolic caiion-complexing solvent or as an intermediate in a free radical chain reaction. Experimental evalu ation of the interactions of a number of sodium/ electron carrier/ solvent systems with 10C oils containing 125-800 ppm of Aroclor* 1254 or 1260 showed that most of the sodium adduct was consumed by reaction with the 10C oil rather than with the PCB, particularly when only low levels of lon-complexing solvent were present. Marked reductions in solvent requirements could be achieved, however, by forming the presumed
201
NGNS 221764
212 PC TREATMENT, RECOVERY AND DESTRUCTION
tdduct in situ, e.g., by simply stirring together the PCB-containing oil, finely dispersed sodium, catalytic quantities of an electron carrier (such as benzophenone or naphthalene) and an ion*complexing solvent, such as diglyme (DGM). Using various specimens of PCB-containing IOC oil that had' been used in transformers, removal of PCB to gas chromatographically undetectable levels (0 2 ppm) could thus be effected in simple process equipment within a few minutes at room temperature.
ORIGIN OF NEED FOR REMOVING TRACE PCB FROM IOC OIL
Between the mid*1930s and 1977, two generic types of dielectric fluids were used in the manufacture of ordinary, liquid-filled, industrial, utility and distribution transformers. The more widely used of these was 10C oil. This is a specially refined mineral oil derived from naphthenic base crudes from certain wellfields. It was selected for its arc-quenching ability (i,e., its ability to consume hydrogen atoms generated by corona via addition reactions rather than Reproducing H-abstraction reactions) and its resistance to autoxidation in use. Chemically, it consists of the same sort of complex mixture of hydrocarbons as found in a low-viscosity lube oil, but with an aromatic content of 15-30% (depending on source), provided mainly by alkyl benzenes and naphthalenes, and a sulfur content of 0.03-0.24%.
The less commonly used type bore the generic name "askarel" (which denotes any nonflammable dielectric fluid) and a variety of manufac turers' trade names, such as General Electric's `PyranoPand Westinghouse's "Inerteen." Askarels, being more expensive than 10C oil. were used only where the fire hazard was considered sufficient to warrant the extra cost, for example, in transformers for indoor commercial or industrial use, or in transformers used on railroads. Virtually all of the askarels used consisted of mixtures of PCB (usually, Arodors 1254 or 1260, which were themselves complex mixtures of PCB homologs and isomers averaging five or six chlorines per biphenyl residue, respectively) and polychlorinated benzenes (mixed isomers of tri- and/or tetrach loro benzene).
Generally speaking, both oil- and PCB-filled transformers were manu factured and repaired in common facilities, As a result, trace levels of each type of dielectric often found their way into transformers of the other type. For many years such contamination attracted no attention, because it did not affect the performance of a specific dielectric in its designed use.
RONS 221765
PCS IN TRANSFORMER OIL 113
Beginning in 1966, however, it was discovered that PCB were highly persistent in the environment and were accumulating to ppm levels in fish and fish-eating wildlife around the world. As a result, in the early 1970s there were (I) voluntary restrictions by manufacturers on the sale of PCB, which were allowed only for totally enclosed uses, such as in capacitors and transformers; (2) provision of incineration facilities for destroying returned scrap PCB; and (3) development of biodegradable types of PCB for capacitor use.
Subsequently, however, investigation [I] of an outbreak of "yusho" disease in Japan traced it to the consumption of nee oil that had accidentally been contaminated with heat exchanger fluid, which con sisted of a PCB that had been pyrolyzed to a mixture of polychlorinated quatcrphenyls and dibenzofurans. Consumption of this oil resulted in transient accumulations of undecomposed PCB in the victims' adipose tissues, chronic accumulation of some toxic penta- and hexachlorodibenzofuran isomen in their liven, and chronic manifestation of chloracne symptoms. This evidence of human hazard led to widespread demands for tight controls on PCB use in Japan, Sweden, Canada and the United States.
In response. Congress enacted the Toxic Substances Control Act (TSCA), of 1976 which generally banned PCB manufacture, importation, distribution, processing or use, and directed EPA to define procedures for the marking and disposal of residual stocks. In regulations promulgated in 1979, EPA set forth such procedures, but excluded from the disposal requirements PCB contained in intact, nonleaking capacitors or trans formers and mixtures containing PCB at concentrations less than 50 ppm. As a result of a court challenge by the Environmental Defense Fund, however, EPA is currently reexamining these exclusions.
The 1979 regulations themselves, however, already mandate special ultimate disposal procedures for somewhere between 300 and 600 million gallons of the 10C oil that is currently in service in transformers or transformer systems, because of contamination with more than 50 ppm of PCB. Since IOC oil is a valuable commodity, for which production capacity is only about 100 million gallons per year, it woul4 seem desirable to develop methods for decontamination and reuse of this oil, rather than simply to dispose of it.
In principle, removal of PCB from mineral oil could be effected by a separation or destruction process. The former would separate the oil into two fractions; a PCB mixture for separate disposal and a PCB-depleted oil for reuse. The latter would solve the PCB disposal problem and give a reusable oil in a single step; therefore, it presumably would be preferable. However, current EPA regulations have been interpreted to require that a
MONS 221766
1*4 PC TREATMENT. RECOVERY AND DESTRUCTION
PCB destruction method that is an alternative to disposal by incineration must achieve an equivalent level of performance, or 99% destruc* tion. Thus, reusable oil prepared by a PCB separation process may contain up to 50 ppm PCB, the lower limit for legally defined "PCB contamination," but that prepared by a PCB destruction process must contain no PCB, within the limits of analytical uncertainty, currently defined as about 2 ppm.
In summary, although it is impossible to predict future regulatory developments in this area, current requirements create an immediate need for small-scale, decentralized facilities for processing batches of oil provided by transformer repair and servicing operations. The challenge facing the chemist is to devise treatment processes that will consistently remove PCB down to levels below 50 ppm, if done by separation, or to 0-2 ppm, if done by PCB destruction. ,
PRIOR USE OF SODIUM OR ANION RADICALS TO DESTROY PCB
PCB are generally unreactive materials. Many of their past applications were, in fact, based on their great thermal and chemical inertness. About the only class of chemical reactions they are known to undergo at low temperatures are electron transfer processes effected by anion radicals, such as the sodium adducts of certain aromatic hydrocarbons.
The use of metallic sodium itself is apparently effective only at elevated temperatures. A Japanese patent [1] reports that 6 hr at 120 C was required for-the removal of PCB from kerosene, or 2 hr if catalytic quantities of isopropanol were added. A Goodyear report [2] indicates that heating with molten sodium to 300C for 6 hr was required for the removal of PCB from a heat transfer oil.
Conversely, the intensely colored solutions prepared by dissolving sodium metal in solutions of certain aromatic hydrocarbons in aprotic, caiion-complexing solvents such as tetrahydrofuran (THF) or DGM are known to react readily with organic halides. The deep blue adduct of sodium and biphenyl is frequently used as an analytical reagent for quantitatively converting organic to inorganic chlorides, and the deep green adduct of sodium and naphthalene has been reported to act similarly on the PCB [3].
Two reports [2,4] have described the reaction between this 1:1 sodium:naphlhalene adduct (naphthalenide anion radical) and PCB in THF solution at 60C in some detail. From examining these reports and the prior literature [5] it becomes evident that a number of types of
MONS 221767
PCB IN TRANSFORMER OIL 20S
chemical reactions can occur in such systems. These generic types of interactions, summarized in Table 1, include the reversible formation of 1:1 (Equation 1) and sometimes 2:1 (not shown) adducts between the sodium and electron carrier; a variety of forms of attack on the solvent system, including hydrogen abstraction, aikoxide elimination and mctallation processes (Equation 2); reductive dechlorination of the aromatic halide, presumably via electron iransfer followed by fragmentation, which produces inorganic chloride and aryl radicals (Equation 3): occasional reduction of the aryl radical by hydrogen abstraction or metallation (Equations 4 and 5); and a variety of radical recombination processes (Equations 6-9). The reported data [4] on the interaction between preformed sodium naphthalenide and various Aroclors in THF solution indicates a net consumption of PCB, naphthalene and THF in roughly comparable molecular proportions and the formation of chlorine-free, soluble resinous products, which we may presume to have been complex mixtures of species derived from various recombination processes, (Equations 6-9),
Tabic t. Centric Types of Reactions Knew* to Occur During Interactions Among Sodium Metal (Na), Cation Carrier* (B), Electron Carriers (C), and Aromatic QUofMaa (ArCl) in Organic Media
Adduct Formation
Na * xB C - NaB/ * (T Solvent Attack, Metallation
(1)
C" * RH - -R. R\ CR-. etc.
C)
Dechlorination C* * ArCt - C CI` 'Ar
(3)
Aryl Radical Reduction
Ar * RH - R * ArH Ar C - C * Ar* (* H>0 - ArH)
(4) <S)
Aryl Radical Recombination 2 'Ar -- Arj
(b)
Mixed Radical Recombination:
Ar -R -- ArR Ar C* - ArC ( H;0 - ArCH) R * C* - RC (* H-0 - RCH)
(?) (S) (9)
MOMS 221768
204 PCB TREATMENT, RECOVERY AND DESTRUCTION
Several papers have described light- [6], radiation- [7] or peroxideinitiated [8] free radical chain reactions between alkali, isopropanol and PCB to give inorganic chloride, acetone and biphenyl. These processes have been presumed to proceed by a pathway analogous to that of the Sherman mechanism [9]: the reversible formation of isopropoxtde (Equa tion 10), its conversion to the anion radical (Equation 11) and attack of the latter on PCB (Equation 12):
MejCHOH * OH- HjO Me;CKO*
(10)
MjCHO' Ar - ArH M*CO`
(II)
MjCO* * ArCl - Cl* + M:CO Ar
02)
The process of Equation 11 is obviously analogous to that of Equation 4, and that of Equation 12 is analogous to Equation 3. From the latter we may conclude that ketone as well as hydrocarbon anion-radicals are capable of attacking PCB molecules at low temperatures.
The question of how well an anion radical-mediated PCB destruction process might perform in a medium that was predominantly 10C oil rather than a cation-complexing solvent is not resolved by either of these bodies of prior literature. In such a medium one might expect the adduct formation equilibrium (Equation 1} to be shifted to the left; solvent attack processes (Equation 2) to be favored over PCB attack (Equation 4); and possible complications from radical reduction processes (Equations 4 and 5), which would mean that incompletely dechlorinated PCB molecules would still appear in the gas chromatogram as PCB, albeit of lower degrees of chlorination, rather than as constituents of a nonvolatile resin.
ASSESSMENT OF SODIUM ADDUCT-PCB INTERACTIONS IN IOC OIL
To assess the pattern of interactions among sodium adducts. PCB and IOC oil, 0J Msolutions of various J:1 and 2:1 adducts were prepared by stirring together under nitrogen the appropriate quantities of sodium metal (40% dispersion in light mineral oil, from Matheson, Coleman, and Bell), the selected cation-complexing solvent (dried over a Linde 4A molecular sieve), and the selected electron carrier The resulting intensely colored solutions were then added, a few milliliters at a time, to 100-m) portions of askarel-contaminated 10C oil. with stirring under nitrogen at room temperature. After the color disappeared from each portion of the adduct, and before addition of the next portion, a sample of the oil was removed for gas chromatographic determination of its PCB content.
MOMS 221769
PCI IN TRANSFORMER OIL 217
which was done by comparing eight of the more prominent peak heights with those in Aroclor 1254 or 1260 standards.
Generally speaking, decolorization of the first few milliliters of added adduct occurred almost instantly in all cases, but with no change in PCB levels, indicating consumption of the adduct by traces of highly reactive non-PCB species such as HjO, Oj or carboxylic acids. The eolors of subsequent portions of the adducts generally persisted for 1-5 minutes, except in the case of the 1:1 sodiur.-benzopheovne adduct (sodium diphenylketyl), which reacted more slowly.
The titration curves obtained by plotting % PCB removed as a function of the relative amount of adduct added exhibited the general features shown in Figure 1. In most cases, as illustrated in the lower part of Figure I, the initial flat was followed by a pseudo-linear decline of PCB with added adduct until a rather sharply defined point of PCB disappearance was reached. In all such cases, there appeared to be little difference in the relative reactivities of the different PCB isomers; the individual peaks in the gas chromatogram maintained roughly the same relationship to each other as they declined. Conversely, during titration with the 1:1 sodhimbenzophenone adduct (upper curves, Figure 1), disappearance of species in the Cl-Clg biphenyl range was accompanied by an initial sharp rise in concentration of those in the CU-CI5 range, and then followed by a slow and incomplete disappearance of the lower homologs. Evidently, this reagent was far more reactive with higher- than with lower-chlorinated biphenyl homologs, and some constituent of the reaction system, pre sumably benzhydrylate (by analogy to Equation II), was capable of transferring hydrogen to the radicals formed from the higher homologs so as to give the reduced products observed.
Returning to the more usual case, where there were no complications arising from partial reduction of PCB, the first notable feature of the titration curves shown at the bottom of Figure 1 was their low slopes, which indicated that most of the sodium adduct was being consumed by reaction with species other than PCB. Similar behavior has also been reported for reactions of sodium naphthalcnide/THF with PCB in heal transfer oil [2}. The second significant feature was their roughly linear (rather than hyperbolic form), indicating that the relative rates of attack on PCB must have been increasing with increasing volumes of tiirani solution in the medium. The latter point was also illustrated by the comparative titrations of IOC oil solutions containing 120 and 800 ppm of PCB; it generally required only 2-5 limes as much titrant to destroy seven times as much PCB.
The approximate relative efficiencies of a number of different adductsolvent combinations in the removal of Aroclor 1254 or 1260 from 10C oil
HOMS 221770
201 PCI TREATMENT, RECOVERY AND DESTRUCTION
Fiftirc I, Change* in PCB level* retultins from titration* of IOC oil* conuintni Aroclor 123* (------- ). 120 ppm, or Aroclor 1260 (--------- ). 100 ppm. with 0J M lolution* of *odium adduct* of benxophenone (Bi) or naphthalene (Np) in di|lyme or tetrahydrofuraa, respectively, at room temperature.
are shown in Table 11. Generally speaking, the relative activities in attacking the less reactive PCB species (rather than unidentified components of the 10C oil), as indicated by the quantities of the adduct solutions that had to be added to achieve complete removal of :he PCB, were roughly comparable for the 1:1 sodium:naphthalene adduct, the 2:1 sodium:biphenyl adduct and the 2:1 sodium:benzophenone adduct. They were somewhat higher for the 2:1 sodium:naphthalene adduct, which formed a very slowly reacting black suspension in the system, decidedly higher for the removal of the more highly chlorinated PCB homologs by the 1:1 sodium:benzophenone adduct, and decidedly lower for the removal of the lower homologs (i.e,, all PCB) by that adduct.
MOMS 221771
PCI IN TRANSFORMER oil jo
Tabic II. Approximate EfTseilven*** of Various
M Sodium Adduct Solution* in
Destroying PCR* In IOC Oil at Room Temperature
Ad duel Nt-Adduct
Formr*
Rsllo
Sol' rnl*
PCB Tip*'
PCB Cone. (ppm)
apcb/ans
% Soln. tor 99% A PCB
(*/*)
Bt
1 1 ETH
1260
*00
0 06'
f
Bt
1 1 THF
1260
*00
004'
f
Be
11
DGM
1260
800
0 0*'
f
Bt
!1
DGM
1254
120
04 `
f
Bt
11
TGMT
1260
MW
o.*
f
Bt
21
TGMT
1260
K00
07 '
10
\p
1 1 THF
1260
800
0.03
20
\p
l.l GLM
1260
KO0
0 02
>20
\p
l.l
DGM
1234
120
0.003
>23
hp
2.1* DGM
1260 K00
0)
1*
Bp
1 1 THF
1260
*00
0.002
20
Bp
2:1 GLM
1260
*00
002
13
*Ai measured by diuppearanee of gas chromatographic peaks in ranft characteristic of G-C| biphenyls. Unless noted (e), ail such peaks disappeared at approaimately same
rate. kKeyt Bx, benaophenons; Np. naphthalene; Bp, biphenyl: ETH, ether THF, tetrahydro-
furan; DOM. diglymr. TCMT, 1:2 tetraglyme-toluene; CLM. |lyme.
*Arodor 1260, mainly mixture of Cj-Qt biphenyls; Aroclor 1234. mainly mixture of
cvet*.
* Ratio of moles PCB lost per mole adduct sodium added determined from approximate slope near middle of titration curve, 'Data for peaks in Cl*-Q( biphenyl range only. rNot jet demonstrated that any quantity of the 1:1 Na-Bt adduct solution sufficient to
remove the less highly chlorinated PCB homolops. 1 Presumed adduct formed by dispersing solid Na*in*naphihatene dispersion (Coronet
Chemical Co.) in digtvme; formed black suspension rather than solution, reactions with
PCB/IOC required several hours rather than minutes.
Seven! rather poorly reproducible experiments using tri-or tetnglyme (which are apparently harder to obtain in consistent purity) suggested higher APCB/ANa ntios than exhibited in runs using DGM as the ion* completing solvent; conversely, somewhat lower ratios were shown by monodentatc complexes such a THF or diethylether (Table 11).
The overall conclusion drawn from these experiments was that if one desired to destroy the PCB in IOC oil with reasonable speed and efficiency by adding to the oil a near-saturated solution of a reactive sodium adduct, roughly 20 volumes of adduct solution would be required per 100 volumes of oil, almost regardless of the choice of adduct or PCB level in the oil. Since the effective ion*complexing solvents are all about 10 times as costly as 10C oil, and since they would almost certainly alter its dielectric
ONS 221772
! FC TREATMENT. RECON ERV aND DESTRUCTION
properties and thermal stability if appreciable amounts were left in oil destined for reuse, it was evident that any practical use of preformed adduct solutions for PCB removal would have to be followed by some reasonably efficient recovery of the ion-complexing solvent.
CATALYZED SODIUM PROCESS FOR DESTROYING PCB IN IOC OIL
To determine whether such substantial needs for ion-complexing solvents in the reaction system could be reduced, we conducted a number of experments in which prior formation of the adduct was eliminated. In these exj>eriments, various types and levels of electron carriers, cationcomplexing solvents, and commercial sodium dispersions were added to Aroclor 1260-containing IOC oil with stirring under nitrogen at room temperatures, and the mixture was checked periodically for disappear ance of both sodium and PCB.
It was observed that there was considerably more batch-to-batch variation in the reactivity of the sodium dispersions than was encountered during preparation of the sodium adducts in ion<omplexing media. Most freshly opened commercial samples appeared to react completely with the IOC/PCB/electron carrier/ion carrier mixtures within an hour, leaving only a fine gray haze of suspended sodium chloride particles. However, in a few cases, reaction was complete within a few minutes, and some older dispersion specimens did not react at all. Evidently, in media consisting of IOC oil containing only 1-5% of ion-complexing solvent, the reaction with electron carrier was more sensitive to inhibition by oxide films on the dispersed sodium particles than in those composed by solvent alone. The rate of sodium disappearance did appear to be related to the quantity of cation-complexer present, but this proportionality was difficult to quantify because of the variability in the dispersion reactivity. Sodium disappearance was accompanied by that of the PCB in roughly the same proportions as observed using solutions of the preformed adducts, i.e., most of the sodium was consumed by reactions with constituents of the IOC oil rather than with PCB, hence, large excesses of sodium were still required for complete PCB removal.
Reaction of the sodium with PCB and IOC oil depended not only on the presence of the anion carrier, but also on that of the electron earner. In parallel experiments using IOC oil containing 800 ppm Aroclor 1260. 5% DGM, and 0.23% sodium with or without 0.32% naphthalene, elimination of the PCB required an hour in the first case and a week in the second. Even in that latter case, an electron earner may have been
HONS 221773
PCB IN TRANSFORMER OIL III
involved: most IOC oils are known to contain some alkyl naphthalenes, and the reaction medium in this case did exhibit the typical deep green color of a 1:1 naphthalene adduct by the end of the week. We have also learned, from another laboratory where this process was being checked, that some Texaco IOC oils, which are particularly high in alkyl naphthalenes, do not require naphthalene addition for successful de chlorination [10}.
A number of parallel runs were made using either benzophenone or naphthalene as the electron carrier, without revealing any significant differences in reaction rates or efficiency of PCB removal. In both cases, the CI4-CI7 biphenyl isomers all disappeared at roughly the same rate without evidence of stepwise reduction, and the reactions proceeded without ever developing more than traces of the intensely colored 1:1 adducts. From these, we concluded that the reactive intermediate was some species other than the 1:1 adduct present in the preformed solutions used earlier, and instead was probably either a soluble 2:1 adduct or else some sort of a surface complex.
The performance of the sodium/ naphthalene/DCM system on a number of different specimens of PCB-containing 10C oil, all taken from transformers returned for service work, is summarized in Table 111. From these data it was concluded that contaminants arising during transformer use would not seriously interfere with use of this system for PCB removal.
Table 111 also points out that in some runs, which were examined by electron-capture gas chromatography just after the disappearance of the dominant CU-CIt biphenyl peaks of the Aroclor 1254 or 1260, there remained some weak peaks in the retention range eovered by the CI2-CU biphenyl peaks of Aroclor 1016. A few of the peaks had retention times similar to those of 1016, and we could not exclude the possibility that such mixtures contained trace of the lower<hlonnated biphenyls, in addition to other electron-capturing species, such as sulfur compounds or autoxidation products. Fortunately, on continuation of the sodium treatment, these enigmatic peaks disappeared in all cases.
To examine the feasibility of process scaieup, a 55-gal drum was equipped with a lid, stirrer and provision for flushing with nitrogen. In a typical experiment, this was charged with 40 gal of PCB-containing IOC oil (which was pumped in through a 30-in. column of 1/ 16-in. pellets of Unde 4A molecular sieve, 087956, to remove any water present), 4 lb of a 20% dispersion of sodium in mineral oil (Coronet Chemical Co., Newark, NJ) and a solution of 1 lb naphthalene in 2 gal DGM (diethylene glycol dimethyl ether, Ansul Chemical Co., Marietta, WI). Gas chromato graphic analysis showed the initial level of Aroclor 1260 to be 852 ppm; after 15 min, 17.6 ppm; after 60 min, 1 ppm.
HONS 221774
212 PC . TREATMENT. RECOVERY AND DESTRUCTION
Table 111. Reductions in PCI Levels Resulting from Stirring Randomly Selected Specimens of Ih4 rCH-Containing IOC Oil with Dlgljme, Naphthalene and Dispersions of Sodium Metal (0.24% w/; 0.10 Af) llndar Nltro|m at 24*C
Initial
Aroclor 12*0 (ppm|
9.tO 434 4t4 410 410 ISO ISO I no mo 372 372 372 372 336 3t6 336 333 333 333
% (*/*> Digljmc Solution Added*
S 3 3 3 J 3 3 5 S 3 3 5 S 2 2 3 1 1 2
Initial Naphthalene
In IOC OH*
(A/)
0 025 0015 0015 0015 0 015 0.030 0 030 0 025 0 025 0.030 0 030 0 025 0 025 0.010 0.010 0015 0.010 0.010 0.020
Reaction
Time (min)
30 30 to 40 40 30 30 30 30 30 30 30 30 30 60 10 15 30 15
% Reduction In PCI
Lower Peaks* (1% of Initial
116#)
Higher Peaks* (99% of Initial
12*#)
92 100
9S 100 91 100 91 100 92 100 91 100 100 100 too 100 99 100 9t 100 100 100 91 too 9t 100 99 100 96 100 99 100 92 91
99 100 too 100
`Naphthalene introduced into IOC oil by adding 1-5% (U indicated) of 0.5 or 1.0 M
solution in diglyme. b Electron capture gas chromatographic peaks mainly in range characteristic of trichlorobi-
phenyis: some, but not all. corresponding to positions of peaks in Aroclor 1016 `Peaks mainly in range characteristic of penta-, hex*- and hcptachlorobiphenyls.
A portion of the resulting Na-treated, but unwashed, oil, which was initially almost clear except for the NaCI haze, and no more colored than the original IOC oil, was allowed to stand with exposure to air for several weeks. As a result, the oil developed a purple color and deposited most of its sodium salts as a black precipitate that appeared reddish-purple in thin layers. This deposit, after filtration and washing with hexane, reacted with water without gas evolution to produce sodium hydroxide and a light yellow, water-insoluble, hydrocarbon-soluble resin.
Examination of this resin by gel permeation chromatography showed a broad, weakly bifurcated peak, with the two maxima at positions cor responding to those of linear polymers with molecular weights of 310 and 620, respectively. (On the same columns, 10C oil itself gave an asymetrical
HONS 22X775
PCB IN TRANSFORM Eft OIL JU
peak, having a centroid and a maximum at points corresponding to polymers of molecular weights 242 and 161, respectively; the actual average molecular weight of IOC oil 1$ about 230.) Examination by gas chromatography showed the lower-molecular-weight population to be a very complex mixture, and field desorption mass spectrometry indicated a detectable peak at almost every mass number between 150 and 350. The Ultraviolet (UV) spectrum of the resin resembled that of an alkyl benzene, with a sharp maximum near 272 mp, but with some broadening on either side. The nuclear magnetic resonance (NMR) spectrum indi cated an aromatic/ aliphatic proton mio of 0.43. The infrared spectrum revealed prominent carbonyl and hydroxyl (i.e., carboxylic acid?) bands in a specimen that had been aged a year; however, these were less evident earlier. It was concluded that the precipitated purple salt was probably an autoxidation product derived mostly from metallation and coupling products of various constituents of the 10C oil (e.g., via processes like Equations 2 and 9), rather than from those of the PCB.
However, the available data do permit certain conclusions to be drawn regarding the nature of the PCB conversion products. First, it is evident from the absence of stepwise reduction products (which were easily detected in the case of treatments with preformed sodium diphenylketyl) that aryl radical reduction reactions (Equations 4 and 5) must be rather unimportant in these heterogeneous systems. Second, the absence of any high-molecular-weight polycondensaies or insoluble polybiphcnyl gels indicates that aryl radical recombination reactions (Equation 6) must also be unimportant. According to classical polymer gelation theory, gelation m a polycondensation of hcxafunctional monomers should occur when the reaction is only 20% complete. In addition, we might note that no gelation has been reported even in systems using high concentrations of PCB [2,4], which would favor arvl-aryl coupling; hence such coupling would appear particularly unimportant in systems where the PCB levels are only 100-1000 ppm. Accordingly, we conclude that most of the radicals generated by the removal of the chlorines from the PCB molecules must be consumed via mixed radical recombination processes (Equation 7 and 8), and hence that the PCB conversion product must consist of an extremely complex mixture of molecular species, each of which contains a single biphenyl nucleus linked to 4-7 aralkyl hydro carbon, dihydronaphthalene or glycol ether residues. Such a product would be similar to asphalt in its chemical and environmental properties.
It is thus apparent that catalyzed sodium processes of the types just described are capable of removing PCB from transformer oil down to the levels sought by the EPA without the formation of objectionable products. Moreover, such processes are capable of being earned out in a
HOMS 221776
2)4 PCI TREATMENT. RECOVERY AND DESTRt CTION
single step at room temperature in simple process equipment and hence are suitable for small-scale, decentralized operations. A minimal objective of such operations would be to render scrap transformer oil acceptable for sale as fuel. Still undetermined is whether the IOC oil treated by this or any of the alternative PCB-removal processes, all of which tend to alter the levels of multicydic hydrocarbons and/or sulfur compounds, as well as those of the PCB and chlorobenzenes, still possesses the long-term oxidative and dielectric stability required for reuse in transformers; how ever, active research on this question is currently in progress [10].
REFERENCES
1. Hiraoka, M,, T. Takase and J. Maisuno. Japan Kokai 74:82,520 (1974); Chem. Absi. 82.89831k (1975).
2. Goodyear Tire and Rubber Co. *A Safe, Efficient Chemical Disposal Method for Polychlorinated Biphenyls-- PCB'i," Research Laboratories Report (1980).
3. Oku, A., K. Yasufuku and H, Kataoka. Chem, !nd. (J978), p. 841. 4. Smith, J. F., and G. L. Bubar. 'The Chemical Destruction of Polychlorinaied
Biphenyls by Sodium Naphthalenide," report from the Guelph-Waterloo Centre for Graduate Work in Chemistry, Department of Chemistry', Univer sity of Waterloo, Waterloo, Ontario (1979). 5. Holy. N. L. Chem. Rev. 74:243 (1974). 6. Nishiwiki, T., A. Ninomiya, S. Yamanaks and K. Anda. Nippon Kcgaku Keisho (J972), p. 2225; Chem. Abtt. 78:29339p (1973). 7. Sawai, T., and Y. Shinoiaki. Chem. Leu. (1972), p. 865, 8. Sawai, T., and T. Sawai. A'oftfi 8:234 (1973); Chem. Abtt. 85:166I60j(!976). 9. Sherman, W. V. J. Am. Chem. Soe. 90:6773 (1968). 10. Rouse, T. O. Personal communication.
MOMS 221777
CHAPTER 12
LIGHT-ACTIVATED REDUCTION OF CHEMICALS FOR DESTRUCTION OF POLYCHLORINATED BIPHENYLS IN
OIL AND SOIL
Judith F. Kitchens, William E. Jones, 111, George L. Anspech end Donald C. Schubert
Atlantic Research Corporation Alexandria, Virginia 22314
Successful commercialization of synthetic halogenated organics began in the early twentieth century. Since that time, halogenaied organics have been used in a wide variety of products, including pesticides, plastics, heat transfer fluids and dielectrics. Ecological damage caused by halogenated organics in the environment was first brought to public attention in 1962, with the publication of Silent Spring [1]. Since this publication, a large amount of research has been conducted,to determine the environmental dangers of these compounds. In general, the halogenated organics are highly persistant in the environment. They also tend to bioaccumulate and cause dewsuting damage to certain species of wildlife and, ulti mately, man. Probably the most insidious of the halogenated compounds produced by man are the polychlorinated biphenyls (PCB). These com pounds were widely used as dielectrics in transformers and capacitors, and as heat transfer agents in heat exchangers from 1929 through 1978. In 1978 the U.S. Environmental Protection Agency (EPA) published its proposed rules, which prohibited the manufacture, processing, distribu tion and use of PCB except in totally enclosed systems [2]. However, the problem that still remains is how to safely dispose of the billions of
215 HOMS 22177
11* PCI TREATMENT, RECOVERY AND DESTRUCTION
gallons of waste transformer oil containing PCB and how to remove the PCB from the environment.
Atlantic Research Corporation (ARC) has addressed the problem of destruction of halogenated organics in wastes and the environment with the development of the light-activated reduction of chemicals (LARC) process. This process was originally developed for destruction of Kepone; however, research has shown that the destruction of PCB extracted from soils and in transformer oils is economically feasible with the LARC process.
LARC is a patented process [3] that uses ultraviolet (UV) light in the 1850- to 4000-A region in combination with hydrogen gas and optimized photochemical conditions to effect dehalogenation of complex chlorin ated and brominated organic molecules. UV light initiates the photo chemical process by homolytic cleavage of the carbon-halogen bonds. The conditions are optimized to maximize this cleavage and the resultant formation of a carbon-hydrogen bond. Mass spectral data from LARC reactions run in deuterated solvents show that the hydrogen for the reduced organic may come either directly from the hydrogen gas or from the solvent, depending on the solvent involved. In either case, hydrogen gas plan a significant role in the photoreduction process since the same reactions with nitrogen substituted for hydrogen proceed at much slower rates.
The LARC process has been applied to reductive dehalogenation of several compounds, of which the most environmentally significant are Kepone in water and PCB from soils and in oils. This chapter discusses research on LARC degradation of PCB from soils and in oil conducted at ARC
EXPERIMENTAL
Two LARC reactors were used in this research: a single-lamp tube reactor and a 64-lamp pilot unit. These reactors are shown in Figures 1 and 2. Both reactors contain low-pressure UV lamps with 95% of their output at 2537 A. The lamps are surrounded by quartz sleeves, which allow greater than 90% transmission of the 2537-A light. The hydrogen gas is introduced into the reactors via 2.0-u fritted stainless steel spargers. The pertinent reactor parameters are:
MOWS 221779
LJCHT'ACTIVaTED REDUCTION OF pc* 117
Number of Lamp* Capacity (lucri) Ught Path Length (mm) Radiant Energy il Lamp Sleeve
Surface (mW/cm1) Hydrogen Flowrate (liter/mm)
Tube Unit 1
0 600 5.33
36 300 0 26
Pilot Unit 64 40 6.3J
29 400 19
Figure I. Singli-lamp LARC reactor.
MOMS 221780
211 PCR TREATMENT, RECOVERY AND DESTRUCTION
Figure 2. Pilot LARC reactor.
Both units are capable of Dow-through or bath-recycle operation. Analysis for PCB and PCB degradation products was performed on a
Hewlett-Packard 5880 or Varian 3700 gas chromatograph (CC) with electron capture detector (ECD) for PCB and Dame ionization detector (FID) for biphenyl. The following gas chrotnaiogaphic conditions were used:
column: 1.95% OV |7/l.5% OV 210 on Anakrom Q, temperature* injection port--500* C; oven--programmed from 135 to 225*C at
20* Cmin; ECD or F1D-KWC: and carrier gat: nitrogen at 25 ml/ mm
Before CC/ECD, the PCB-containing solutions were diluted with ben zene to a PCB concentration less than 2 ppm. PCB IN SOIL
If LARC is to be useful for destruction of PCB in soils, the PCB must first be extracted from the soil. Several solvents were evaluated for their
MONS 221781
LICHT-ACTIVaTED reduction of PCI 21
ability to extract the PCB from toil without previout treatment and for their ability to act at a LARC solvent. A clay toil containing approxi mately 2000 pg/( of Aroclor 1242 was used in this investigation. The Aroclor 1242 had been spilled on this soil approximately 10 years previous to the extraction experiments. Of the potential solvents with suitable UV transmission characteristics for LARC, the low-molecularweight alcohols were found to be the most suitable extractants. Methanol, ethanol and isopropanol all yieided >88% extraction efficiencies with each extraction step.
The extract was then filtered, as shown schematically in Figure 3. Solid sodium hydroxide was added to the filtrate, and the filtrate was subjected to LARC treatment. The extracted soil can then be returned to the original site. Excess alcohol can be removed from the soil by blowing warm air over the filter or by seeding the soil with an actively growing culture of Pseudomonas sp. After LARC degradation of the PCB, the alcohol can be reused after distillation to remove the PCB degradation products, sodium chloride and biphenyl,
The effectiveness of methanol, ethanol and isopropanol as LARC solvents for Aroclor 1242 was then determined. As shown in Figure 4, isopropanol was the best of the three solvents, with 85% of the PCB degraded after a 20-min reaction time. In methanol or ethanol, only 43 and 74%, respectively, of the Aroclor 1242 was decomposed after 20 min.
Fiture 3. Schematic of extractor,'LARC procedure for removel of PCB from toil.
HONS 221702
: PCI TREATMENT. RECOVERY AND DESTRUCTION
100
so
00
70
; oo
- 50
Ss *.0
0 7C
20
10
ARoCkQV 12*(2 IN Mile MCTHMOL INITIAL CONCENTRATION EM RAN
AR0CLOR 1212 IN BASIC UOAROtANOl INITIAL CONCC NT RAT I ON 500 RRN
AROClOR 12R2 IN BARIC ITMANOL 1N|1|AL C0NCCNTRATION 775 RAN
NO M 60 M ACT I ON Tll ININ )
Fl(vrc 4. LARC degradation of Aroelor 1242 in venom lolvcnu.
The rates or LARC reduction of the various Aroc)ors()242, 1254 tnd 1260) extracted from toil were investigated. Isopropanol was used for the extractions, and solid sodium hydroxide was dissolved in the isopropanol extract before LARC. The single-lamp reactor was used in most of these studies. For comparison purposes, a run was made in the pilot unit using the Aroelor 1260 basic isopropanol extract. The results of this investiga tion are presented in Figures 5 and 6. The plot of In C0/Cvs reaction time shows an initial and final degradation rate. The rate constants calculated from these plots are:
HONS 221763
LIGHT-ACTIVATED reduction of PCR III
Single Lamp Reactor Pilot Reactor
Aroclor
1242 1254 1260 1260
*1, (min'1)
0.010 0 0*6 0.112 0.231
kri (min'1)
0 0206 0 046 0 032 0 056
The initial degradation rates appear to increase with increasing chlorine* lion of the biphenyl, i.e., with higher Aroclor number. The final degrade* tion rates are 25-50% of the initial rates. Dechlorination of Aroclor 1260 initially proceeds about twice as fast in the pilot unit as in the single-lamp
100
90
to
70
l C l 60
ii
8
5 50
5 1 3 0 I fe - jo
10 .
10 *-
10 JO
no
H*;T|on Hit (mini
Figure 5. LARC degradation of Aroclor 12^2. 1254 and 1260
HONS 221784
Ill PC* treatment, recovery and destruction
KIACTIOT. TUG 1**I
Fifurc 6, Companion of degradation rates of Aroclor 1260 in the tingle'lamp and pilot reacton.
reactor. This increased degradation in the pilot unit is due to the higher light Dux and optimized temperature and flow pattern.
Several experiments were conducted to determine the practical upper concentration limit for LARC degradation of Aroclor 1260 in basic itopropanol. The practical maximum initial concentration it approxi mately 3500 ppm. Concentrations <5000 ppm can be employed. However at higher concentrations, the reaction rate declines due to the increased amount of the interfering biphenyl final product.
HONS 221785
LJCHT-ACTIVATED reduction of pci iu
PCB IN OILS
Before LARC can be successfully used for degradation of PCB in oils such at transformer! and heat exchanger fluids, several basic problems associated with photochemical degradation of PCB in mineral- and silicon-based oils must be overcome. These problems include:
I'V light-absorbing oil degradation product* arc preseni in many transiormcr fluid*. Mott of the oil* arc not good hydrogen source*. Some of (he oil* arc too \tscous for adequate ditpenion of the hydrogen ga*. The PCB degradation product u a yellow-brown polymer substance that also
absorbs UV light.
Cleanup of the transformer fluids to remove the brown to black UV light-absorbing oil degradation products can be accomplished with chromatographic processes. Commercial transformer cleanup operations use fuller's earth or some other chromatographic medium to remove these degradation products from the oil. Transformer oil cleaned up by these processes should be of sufficient clarity for LARC degradation of PCB.
Several diluents were evaluated to decrease the viscosity of the transformer oils and to provide a good hydrogen source to aid the LARC reaction:
Cnnstilwtnls
Oil:Hexane:lsoprnpanol OiWiopropanol:Hexinc Diethviciher Oil. Tetrahydrofuran Oil. Tetrahydrofuran Oil Tetrahydrofuran Otl.TcirahydrofuraniBuic Methanol Oil Tetrah>drofuran.lsopropanol
Ratio
5..V75 1.25 8 1,0,5 0 5 ^? 82 91 8 1 5'0 5 *2 1
For these experiments, clean mineral oil was used as the oil. The oil mixtures were spiked with Aroclor 1260 to give initial PCB concentra tions of 1000-2000 ppm. In all cases, the rate of LARC destruction of PCB was faster than for PCB in the mineral oil alone. The addition of tetrahydrofuran further improved the PCB degradation rate over that of the hexane formulations. The rates for Aroclor 1260 degradation did not vary with the amount of tetrahydrofuran added in the tested 1Q-J09& range. The addition of basic methanol also did not improve the PCB degradation rate over that of the 9:1 oihtetrahydrofuran mixture. The addition of isopropanol to the oil:tetrahydrofuran mixture significantly improved the initial degradation rate (Figure 7).
MQNS 221786
224 PCI TREATMENT. RECOVERY AND DESTRUCTION
300 f
90
CO
2 s iw*-ra %
" eo 8
I.
i
4 g 40
8 M
JO
20
10
1.0 Lift* lOiullONr
100 L 110**0**401
_ *L AftOUOi 1260
700 IKSTSAL
MCl OONILCtKTMTIOftl
M2.7
Figure 7.
10 20 30 40 SO 00 nAcnoM ijc imm)
LARC dtfradtiion of Aroclor 1260 in oil.
70
The reaction mechanism appears to be rapid dechlorination of the PCB with concurrent formation of hydrochloric acid and a nonchlorinated yellow-brown substance that is believed to be a polyphenylene. No evidence of chlorinated furans or chlorinated dibenzofuran was found in mass spectra of the degradation products.
As shown in Figure 7, formation of the yellow-brown substance significantly inhibits further degradation of the Aroclor 1260, and must be removed. Several solvent extraction procedures have been evaluated for removal of this substance. One method that appears to work satisfactorily is a proprietary aqueous extraction technique. The reaction products from the experiment in Figure 7 were subjected to batch extraction and retreated by the LARC process. The results, shown in Figure 8, indicate that this extraction procedure does remove the
MONS 221787
UCHT-ACTIVaTED reduction of PCI US
Flfim I. Continued LARC degradation of Aroclor 1360 after extraction of poly phenylene produet.
interfering product and allows the PCB degradation to proceed at a reasonable rate. ARC is investigating a continuous extraction method for removing the yellow-brown substance from the oil. CONCLUSIONS
LARC degradation of PCB extracted from soil with isopropano) is a feasible process. Degradation of PCB in transformer oil requires both cleanup of the initial oil and removal of the yellow-brown final product before LARC degradation of PCB in this medium is effective. Cleanup of thu transformer oil is commercialK available technology Removal of the
MONS 221788
II* PC TREATMENT, RECOVERY AND DESTRUCTION
degradation product is effective in a batch process. Continuous extraction of this degradation product is currently under evaluation. REFERENCES 1 Carton. R. Silent Spang (Boston. MA' Houphton Mifflin Co., 1962).
2. U.S. EPA. "Polychlorinated Biphenyls (PCBs)-- Manufacturing Processing, Distribution in Commerce, and Ute," Federal Register 4J(IIO):248Q!-248t8 (1978).
3. Kitchens. J, "Dehalogenahon of Halogcnated Compounds,* U.S. Patent #4.144,132 (1979).
ROMS 221789
CHAPTER 13
CATALYZED WET OXIDATION OF HAZARDOUS WASTES
R. A. Milltr and R. D. Fox IT Enviroscienee Knoxville, Tennessee 37923
Small chemical companies and formulation operations have always been faced with the difficult problem of economically treating lowvolume aqueous and organic hazardous wastes, Economies of scale for thermal incineration or biological treatment can be achieved only by large-volume waste streams. Small waste generators therefore must use commercial waste disposal services. However, many companies desire to have total control over the cost and proper disposal or destruction of their wastes. Therefore, a hazardous waste treatment process that is capable of destroying and/or detoxicating low-volume waste streams at reasonable cost to the wssie generator is desirable. There are a number of existing treatment methods that are capable of either completely (using expensive reagents) or partially (using an inexpensive reagent) destroying hazardous wastes. However, there is a treatment process under development that combines the advantages of a number of treatment methodologies into a system that offers the small hazardous waste generator an alternative to offsite disposal or treatment services. The process, catalyzed wet oxida tion (CWO). harnesses the potential of powerful oxidizing species to oxidize organics to carbon dioxide, water and inorganic salts with the economy of using the oxidation potential of oxygen.
The CWO process is based on a U.S. patent [1] which demonstrates the use of nitrate and bromide or iodide ions in an acidic solution to catalyze
227 HONS 221790
21* PC TREATMENT, RECOVERY AND DESTRUCTION
the oxidation of organics by oxygen. The catalyst system originally was developed for oxidizing soluble organics in aqueous wastes, but has been modified to permit its application to insoluble organic residues. An improved catalyst system for these applications is described in another U.S. patent [2].
WET OXIDATION OF ORGANICS
The concept of wet combustion of organics is aimed at reducing the energy required for treating a waste, and uses an inexpensive and readily available reagent: oxygen or air. The energy reduction is twofold. The first savings results from a lower operating temperature than other destruction processes (for example, thermal incineration, which requires temperatures up to 1200*C to destroy chemical wastes). The second savings of a wet combustion process results from organic oxidation in the aqueous phase, rather than in a vaporized or gas phase, which requires energy for vaporizing the water associated with the waste. The chemistry of wet oxidation [3] relies on the formation of free radicals, which oxidize the organics. Oxidation of the organic results in the formation of additional organic radicals that propagate the reaction sequence:
RH * O, - R'* OOH
<t)
R` Oj - ROO`
(2)
ROO' * RH - ROOK R'
(3>
There are two major considerations m maximizing the rate of the above reactions: oxygen availability and the formation of radicals. Although oxygen availability in aqueous solution is very low at room temperature because of solubility and diffusion limitations, oxygen availability is much greater at wet oxidation temperatures (315 C) [4], and is no longer rate-limning. However, the main limitation for wet oxidation processes is the formation of radicals, which is considered to be a relatively slow and probably rate-limiting step. Radical formation via reaction of molecular oxygen (Equation 1) with the organic molecule is one of the postulated sources of radical* that initiate the organic oxidation sequence. Another postulated source of radicals is an equilibrium between water and oxygen that generates hydroxyl radicals, a very powerful oxidant.
Both conditions for radical formation are met in commercially pro duced wet oxidation systems. To achieve these conditions, operating temperatures of 220-320C with corresponding pressures of 1000-2500 psig arc required. The CWO process addresses these considerations by
RONS 221791
l
CATALYZED WET OXIDATION J2
using the bromide-nitrate caulyst to achieve similar or better organic destruction rates at lower temperature and pressure.
CATALYTIC WET OXIDATION
The catalysts used in the CWO process are capable of accelerating the chemical sequences that occur in wet combustion processes through a series of reactions with oxygen and specific bromine and nitrogen compounds. The major impact of the catalyst system is to lower the temperature of the organic destruction process. These reactions and the chemical species produced perform the same basic functions already described in wet combustion chemistry. The mechanisms by which the catalysts operate have been postulated after extensive experimentation with the aqueous bromide-nitrate catalyst, and examination of the literature on the reported mechanism for wet combustion of organics in aqueous solution to obtain an understanding of how die CWO process achieves faster destruction rates for waste organics.
The first of the three roles performed by the catalyst system is to increase the transfer of oxygen into the aqueous medium at relatively low temperatures. Although this transfer occurs in uncatalyzed wet combus tion, it is a slow process, due to the low solubility of oxygen at tempera tures below 200C. The bromide-nitrate catalyst system accelerates the transfer of oxygen into solution through the complex reactions of the oxides of nitrogen and their solubility in the aqueous catalyst solution:
I N0*0#2 NO;
(4)
2 NO, * H.O ** HNO; * HNOj
(5)
H;0 * HNO, * 2 NO 3 HNO,
(6)
HNO: * HBr ** NOBr H;0
(7)
These reactions and subsequent reactions with bromine/bromide species provide the formation of radicals for the oxidation of waste organics. The
principal radical species used in CWO is not the product of oxygenorganic reactions found in wet combustion systems, but is postulated to be a bromine anion radical. This radical is a strong oxidant capable of abstracting hydrogen from organic molecules. Once radicals are formed, the chemistry becomes similar to conventional wet oxidation, except that the CWO catalyst system has the ability to generate other radical species. It is postulated that the formation and use of the bromine anion radical is responsible for the increased destruction rate of organic compounds by
HONS 221792
139 PC* TREATMENT. RECOVERY AND DESTRUCTION
CWO. When the three roles of the catalyst system (oxygen fixation, radical generation and organic oxidation are tied together, it becomes apparent that the bromide-nitrate catalyst system reactions depend on maintaining the proper relationship between liquid catalyst species, gaseous catalyst species, oxygen and the organics to be oxidized.
EXPERIMENTAL RESULTS
The data were generated from experiments in a titanium reactor [5]. The experiments consisted of batch reactions with a variety of organic compounds over varying conditions of time, temperature and catalyst mixtures. After extensive experimentation with the catalyst system, two conclusions were reached. The first conclusion was that the bromidenitrate catalyst system was capable of destroying organic compounds at much lower temperatures than uncatalyzed wet oxidation. This is demon strated in Table 1. Destroying organics at lower temperatures reduces the operating temperature and resulting pressure of the treatment process. Lower pressures and temperatures reduce the waste treatment cost by lowering the capital cost of the equipment and minimizing operational problems such as corrosion, For certain organic wastes, the operating temperature and pressure are low enough to permit waste treatment using conventional chemical process equipment. This capability makes CWO an attractive waste treatment alternauve for small chemical production or formulation operations.
CWO can destroy eeruin hazardous wastes that are immune to conven tional wet oxioation. These compounds are typically very stable and require higher temperature and longer reaction times to achieve accept able destruction rates. Two polychlorinated biphenyls (PCB), tetrachlorodibenzo-p-dioxin (TCDD) and the CWO reaction conditions are listed in Table II. Although the temperatures and reaction times are much
Table 1. Organic Destruction bv Catalysed and Conventional Wet Oxidation*
Reaction Tima (min)
Organic Destruction
Wet Oxidation
CW'O
Acetonitrile Diphenyl Hydrazine Pentichlorophenol o*Xylenc DDT
30 30 30 60 60
5% 19% 7% S4%
10%
90% 73%
99% 94%
60%
`Reaction temperature: 163* C. catalyst mixture: 0 3% Br~. 3.0% NOj". 0.23% Mn
RONS 221793
CATALYZED wet OXIDATION 231
Tsbk II. CWO Destruction Row for Hiardwo Wmo
Ttmperatur* ro
Ruction Him (mini
Aroctor 1016 Aroclor 1254 TCDD
200 250 200
120 120 240
Percent Destruction
171 97 0 995
higher for these waste compounds, it is possible to design a mobile batch reactor process that can destroy hazardous wastes at the waste site. This concept avoids the risks associated with transport of hazardous waste and eliminates the problem of finding a disposal company capable of respon sibly destroying the waste.
CONCLUSIONS
CWO can destroy a wide variety of waste compounds. The process destroys organic chemicals at much lower temperatures than conven tional wet oxidation systems. The milder operating conditions and resultant process design options make CWO an attractive waste treatment alternative, especially for small waste generators who wish to maintain economic and legal control of their wastes. The improvements associated with the catalysts of the wet oxidation process were achieved through an understanding of the process chemistry and the identification of limiting reactions. Subsequent improvements, such as the bromide-nitrate cata lyst. not only reduced the operating conditions and treatment cost, but also expanded the list of wastes suitable for treatment by the process. As we continue to deal with the problems of hazardous wastes and stricter government regulation, we must look at the process chemistry to improve the performance of waste treatment.
ACKNOWLEDGMENTS
We recognize the dedicated efforts by J. Johnson and D. Demott in collecting experimental data. Dr. J. R. Mover and Dr. R. W, Diesen. Dow Chemical Company, Midland, Michigan, developed the initial catalyst system and made other valuable contributions.
MOWS 221794
232 rc TREATMENT. RECOVERY AND DESTRUCTION
REFERENCES
), Diesen. JL W., and J. R. Moyer. "Wet Combustion of Organics,' U.S. Patent 3,984.311 (October 5, 1972).
2. Miller, R, A. "Destruction Method for the Wet Combustion of Organics,11 U.S, Patent 4.276,198 (June 30, 1981).
3. Rohrer, E. Chem. Ind. (October 15, 1977), pp. 316-321. 4. Othmer, D. F, Meek, Eng, (December 1979), pp, 30-37, 5. Miller, R. A,, and M. D, Swientoniewshi, "The Destruction of Vanout
Organic Substances by A Catalysed Wet Oxidation Process,11 Report pre pared for the U.S. EPA, Contract No. 68-03-2568, Work Directive T-7016,
MOMS 22179$
CHAPTER 14
KINETICS MODEL AND SIMULATION OF CONCENTRATION VARIATIONS OF SPECIES OF POLYCHLORINATED BIPHENYLS INVOLVED IN
PHOTOCHEMICAL TRANSFORMATION
E. V. Kilnws Department of Engineering Science end Mechanics University of Tennessee Knoxville, Tennessee 37916 HDR-Sciences Division Knoxville, Tennessee 37923
R. B, Craig and C. W. Zimmerman Department of Engineering Science and Mechanics University of Tennessee Knoxville, Tennessee 37916
Polychlorinated biphenyls (PCB) are potentially toxic and carcino genic compounds whose large-scale use over the years has made them ubiquitous in the environment. A recent study by the National Academy of Sciences indicates that total U.S. PCB use as of 1976 was 6.1 * 10* kg [1]. The Atlantic Ocean appears to be a major sink for PCB, accounting for 80% of the PCB burden in the environment. Many freshwater lakes and rivers also serve as sinks for PCB.
Most PCB released into the hydrosphere are expected to end up either adsorbed onto sediment or resting as sludges at the bottom of rivers, lakes and oceans. Transport of PCB in rivers is thought to take place by solution and readsorption onto sediment, and by transport of sediment itself.
233
MOMS 221796
234 PC TREATMENT, RECOVERY AND DESTRUCTION
Atmospheric transport plays a major role in the worldwide dissemina tion of PCB [2-5}. Most of the transport of PCB to the North Atlantic is thought to be atmospheric. PCB transport to freshwaters, such as Lake Michigan, is also thought to have an important atmospheric component. PCB released directly into the atmosphere adsorb onto particulates and are transported with the prevailing winds. Particle fallout and precipita tion deposit the PCB on land or into a body of water. PCB were presumably released in highest concentrations during 1960-1976, pri marily to the air and water near urban, industrialized areas. However, current data show measurable levels of PCB in air, freshwater and marine samples from both industrialized and remote areas, suggesting that contamination is still occurring [6]. The sources of contamination by these chemicals generally include agricultural runoff; municipal applica tions; and direct discharges into rivers, estuaries and coastal waters by municipal and industrial activities; and power plants [4], Jn general, laboratory photodecomposiuon of lower-chlorinated PCB isomers in both polar and nonpolar solvents reveals a potential parallelism to the environmental mechanisms that could effectively degrade these con taminants [7].
PCB are similar to many chlorinated pesticides, which are known to bioaccumulate to high concentrations in the higher trophic levels. Com mercially prepared PCB exist as seven complex mixtures that contain a total of at least 54 chlorinated hydrocarbons (biphenyl). If introduced into the aquatic environment as combinations of the seven mixtures, the system may be considered to be an aqueous solution containing in excess of 50 nonelectrolytes. By including the aquatic organisms and other natural and manmade suspended solids, photodecomposition becomes a primary concern. The toxicity of this system to aquatic communities may be due to photochemical products of oxygenated compounds such as chlorodibenzofurans. Since photochemical products of PCB maybe toxic and can accumulate in living organisms, even trace amounts of these compounds may have deleterious effects at higher trophic levels.
Since PCB mixtures occur dispersed in rivers, estuaries and seawater at levels up to 150 ng/l [6,8], appropriate conditions exist for hydroxylation and dibenzofuran-formjng environments. Indeed, the notable absence of the lower^hlorinated biphenyls from most environmental samples sug gests an important role of photodecomposition in the environmental fate of PCB, the interpretation of their source and movement, and prediction of toxic effects on aquatic life [8]. Photolysis of PCB at wavelengths >290 nm (i.e., sunlight) indicates the environmental significance of such nonbiological degrdation [9], Due to an interesting set of attributes of PCB. two sets of environmental consequences exist. Most PCB species are
MOMS 22179?
KINETICS AND SIMULATION OF PCI PHOTOLYSIS 235
nonvolatile and hydrophobic in aquatic environments. Thus, they will either cluster as aggregates of drops in water or reside at the surface in the hydrophobic, nonpolar, hydrocarbon thin-films that spread over the surface. This latter condition increases exposure of PCB to the ultraviolet radiation of the sun. thus maximizing photochemical decomposition. In an aqueous environment, they would be subject to hydroxylation and subsequent potential formation of chlorinated dibenzofuran. Such con version, however, is far less likely in the environment than reductive dechlorination.
Creation of free radicals by sunlight allows environmental replacement of chlorines by hydroxy groups from water without the intervention of alkali when this occurs at the ortho position (found to be the most preferred for chlorine loss). The resulting 1-hydroxychlorobiphenyl is perfectly positioned to allow oxygen to bond to an ortho position on the other ring. This results in formation of the potentially most important class of contaminant in PCB mixtures: the highly toxic chlorodibenzofurans [8], Dispersal in seawater implies that all but a small fraction of the soluble PCB will be too deep to be affected by photolysis by the sun. Thus, the general inertness of PCB combined with the results of gradient distribution due to differential solubility implies that PCB will probably persist in the marine environment.
The photochemical kinetics model was developed to predict the change in concentrations and formation of predominant PCB under the influence of sunlight in a microsurface layer of aquatic environments. The rate constants of the photochemical reactions and initial concentrations of each chemical species are considered in the kinetic model. The computer code uses the reaction rate constants, average surface temperature and pH of the complex photochemical reactions in surface waters. The kinetics model incorporates ihe most important photochemical reactions that are known to occur when PCB are discharged into the aquatic environment over relatively long periods of time.
PHOTOLYSIS
One of the most ecologically significant degradation processes of PCB is photolysis in aquatic environments. The accepted route for the photo chemical excitation of PCB isomers in the 280- to 320-nm region occurs by a transition of electrons in the ground state to an excited state. From the excited state, which can be singlet, double and triplet multiplicity, the carbon halogen bond undergoes fission, giving rise to aryl and hydrogen radicals. The radicals then abstract hydrogen from the medium or
HONS 221798
2M PC TREATMENT, RECOVERY AND DESTRUCTION
dimerize. In addition, a hydrogen halide can alto be detected. Before bond fission, an alternative reaction between the excited state and nucleophilic species can occur, giving the appropriate substitution prod* uct at the C-X bond.
Photochemically induced degradation of isomers and commercially synthesized mixtures of PCB has been reported [10,11]. Reaction rate comparisons in oxygen-saturated and degassed solutions indicated a marked reduction in rates in the presence of oxygen. The cleavage mostly takes place on the 2,2\6,6\ ortho chlorine substituents. Since biphenyl has a planar excited state geometry, coplanarity between the rings increases conjugation and stabilizes excited state molecules. The ortho chlorine substitutes sterically hinder the coplanarity between the phenyl rings. These groups are specifically cleaved in preference to substituents at the mr/s and pore positions.
It is possible that fission of the ortho chlorine substituents is due to stabilization of the transition state by complexation of the leaving halogen atom with the system of the other phenyl ring. Thus the ortho position, being closest to the ring, would facilitate cleavage. Substitution by the solvent could occur via nucleophile attack on the triplet or attack on a radical cation. Photolysis of PCB in aqueous solutions showed that dehalogenation and substitution products were accompanied by chlo rinated biphenylenes and the highly toxic chlorinated dibenzofurans.
Fifurc 1. Photochemical dehalogentnon of 2,2\4,4'-itirachlorobtpheny! (9).
HONS 221799
KINETICS AND SIMULATION OF res PHOTOLYSIS 137
Thus, photochemical degradation can both detoxify PCB in aqueous conditions due to the formation of lower-chlorinated PCB isomers, and toxify with the formation of the more toxic chlorinated dibenzofuran and chlorobiphenylol phoioproducts. Different pathways operating to give replacement of chlorine by hydrogen and methoxy groups and inter mediates inferring the corresponding mechanism are shown in Figure I.
PHOTOCHEMICAL KINETICS COMPUTATIONAL METHOD
The formulation of the complex photochemical reactions of differential equations reduces to equations for a single-stage photochemical kinetics process [12]. The differential equations for the changes in the reactant concentrations are derived directly from the stoichiometic equations. In the photolysis process, the reactions are assumed to be irreversible and displaced toward formation of the reaction products.
The values of the parameters of reactions and the special initial diluted concentrations were determined on the basis of measured data and theoretical considerations of the photochemical reactions. Most of the photochemical reactions that are known to occur when PCB are exposed to UV irradiation (280-320 nm) and/or sunlight were included in the model.
The photochemical kinetics model uses the basic principle of "law of mass" and considers the photolysis reactions In terms of reaction rates. It predicts the variation of net rate of formation and consumption of the chemical species in the system based on their initial diluted concentra tions. The kinetics code calculates the depletion of chemical species as a function of photolysis rates, pH and temperature, and simulates the variations of concentrations as a function of time.
RE5ULTS AND DISCUSSION
The photochemical kinetics study shows that the chemical nature of the compounds formed in the photolysis process depends mainly on the presence of ortho- and pcrc-chlorobiphenyls in aquatic systems. Con centration variations of PCB in aquatic environments under the influence of sunlight may not be detectable by conventional measurement tech niques. Also, there are analytical difficulties in measuring the highly toxic photolysis products of dibenzofurans in the aquatic environments.
HOMS 221000
1JI PC* TREATMENT. RECOVERY and destruction
Fi|iirf 2. Conetmniion variations of 4<h)orobipheyl within a body of water and ihtn film* alone iht turfaw of water in fix month*.
Simulation of a tmill variation in concentration of the PCB under the influence of sunlight that may not be detectable by the conventional measurement techniques is shown in Figures 2 and 3. Photochemical reactions give three types of products, depending on environmental conditions: (I) chlorine is replaced by hydroxy groups in aqueous systems, (2) chlorine is replaced by hydrogen (reductive dechlorination) in nonpolar systems, and (3) chlorine is replaced by hydroxy groups in polar systems. From the results above it is apparent that dechlorination of biphenyls in aquatic environments proceeds very slowly, with consump tion of ortho- and pjrtf-chlorobiphenyl. The results of this study also show that highly chlorinated biphenyls are more stable under the influence of sunlight than less chlorinated biphenyls. The exact reason for the differences in persistence of the highly chlorinated biphenyls is not known, as loss of chlorine is related to the action of hydroxy groups in aqueous systems.
MOMS 221801
KINETICS AND SIMULATION' OF PC* PHOTOLYSIS U*
Fi|tm 3. Coneenmiion variations of :j',4.4`6.6'-hexoehlorobiphenyl and 4,4'. dtchlorobiphcnyl.
The environmenul significance of the formation of chlorinated di benzofurans is threefold: (I) or/Ao-chlorobiphenyls can be hvdroxylated by radiation (sunlight) when they are syspended in aqueous media; (2) the products are convened to chlorinated dibenzofurans; and (3) rates of formation of chlorinated dibenzofurans by this process are the same as their rates of degradation, leading to steady concentrations. The chlorodibenzofurans formed from chlorobiphenyl under photochemical condi tions lead to oxygenated products in six months. Dechlorination of PCB exposed to sunlight was also observed to a certain extent. Irradiation of 2,8-dichlorodibenzofuran resulted in slow dehalogenation in aqueous suspension.
These limited results do not allow direct comparison of environmental dibenzofuran degradation rates with rates of photochemical degradation
MONS 221802
14* PCS TREATMENT. RECOVERY AND DESTRUCTION
observed for some chlorodibemofurant. However, it seems possible that most isomers will not accumulate excessively in the environment (with the possible exception of a 2-chlorinated dibenzofuran).
ACKNOWLEDGMENTS
The authors are grateful to Dr. A. O. Bishop, Jr., Associate Director of the University of Tennessee Computing Center, for his assistance and cooperation in making the computing facilities available to us. We also wish to thank Mr. H. H. Wilson, for his assistance in preparation of this manuscript.
REFERENCES
1. `Polychlorinated Biphenyls,** National Academy of Sciences. (1979), pp. U-25.
2. Fullter, B., J. Gordon and M, Kornrtich. "Environmental Assessment of PCBs in the Atmosphere," EPA Report EPA-40/377-045 (1977).
3. Risenbrough, R. W,, B. W. deLappc and W. Walker 11. Mar. Pott. Trans. (1976), pp. 261-321.
4. Duee, R. A., E. K, Duursma, Mar, Chtm. 3:319 (1977), 5. Nisbet, I. C. T., and A. F. Strofira. Environ. Health Persp, 1:21 (1972). 6. Kalmaz, E. V., and G, D. Kalmaz. Eeot. Modelling 6.234 (1979). 7. Huttin|er, O., S. Safe and V. Zitko. The Chemistry ofPCBs (Cleveland, OH:
CRC Press, !nd,, 1974). t. Crosby, G. D.. K. W. Moilamen, Bull. Environ. Content. Toxicol. 10(6).374
(1973). 9. Sissons, D.. and D. Welti. J. Chromaiog. 60(1): 15-32 (1971). 10. Ruzo, L. O.. M. J. Zabik and R. D, Schueiz. J. Agric. Food Chtm,
22(2); 199-202 (1974). 11. Hutzinger, 0,, S. Safe and v, Zitko. Environ. Health Persp. 1:15-20(1972), 12. Emanuel. N. M.. and D. G. Knorre. Chemical Kinetics of Homogeneous
Reactions (New York: John Wiley L Sons, Inc.. 1973).
HONS 221803
SECTION 3 DESTRUCTION OF DIOXINS;
CASE STUDIES
MOMS 221004
CHAPTER 15
CHLORODIBENZODIOXINS AND CHLORODIBENZOFURANS: AN OVERVIEW
Thorn** 0. Tl*rn*n Brehra Laboratory and Department or Chemitiry Wright State Univenity Dayton, Ohio 43439
Chlorodibenzodioxins (ODD) and chlorodibenzofurans (CDF) are two tenet of tricyclic aromatic compound! that exhibit similar physical and chemical properties and that apparently induce similar biological effects. Generalized structures of the ODD and CDF and the numbering accord ing to the position of chlorine substituents on the rings are shown in Figure 1. The number of chlorine atoms in the molecule can range from one to eight,* therefore, a large number of positional isomers are possible. The total number of CDD is 75, and there are 133 CDF. The numbers of CDD and CDF isomers as a function of the number of chlorine atom substituents are indicated in Table 1.
In the past few years, widespread concern has arisen with respect to contamination of the environment by CDD and CDF. This concern has been prompted in part by observations, principally based on animal studies, that indicate that certain of the CDD and CDF exhibit potent toxicity. In addition, it has been recognized that, since the CDD and CDF are present as contaminants in numerous commercial chemicals that have been or are being produced and used in large quantities [1], the potential for extensive environmental contamination by these compounds is very great. Moreover, CDD and CDF generally are quite stable, chemically and thermally, and are reasonably soluble in several common organic solvents (selected physical properties of two representative chlorinated
243
HONS 221805
244 DESTRUCTION OF DIOXINS
9
I
Chlorinoted Dibenzo-?-dioxin
9I
Chlorinated Dibenzofurans
Figure I. Generalized iiruciuret of CDD and CDF.
Table I. Number* of CDD and CDF Itomert at a Function of lb* Number of .Chlorine Substituent*
Number of Chlorine Atom
Number of CDD botnet*
Number of bomen
I 24 2 10 16 ? 14 28 4 22 28 s 14 28 6 10 16 7 24
< 11
dioxins are shown in Table II). There is some evidence to suggest that the CDD and CDF are accumulating in the environment, and that these compounds persist for considerable periods.
The purpose of this chapter is to give a concise overview of the present status of knowledge of the CDD and CDF, as a prelude to discussions of
MONS 221806
CHL0R0DIKNZ0DI0X1NS AND CHLORODIBENZOFIRANS 243
Tikii II. n^bl Propertim of Two Chlorinated Diotlnt
1J.7A-TCDD OCDD*
Empiric Formula
CuCleOj
Percent by Weight C 0 H a
44.7 9 93 1.25
44 1
31.3 7.0
SI.7
Molecular Weight
322 439.1
Melting Point (*C)
303 130
Decomposition Temperature (*Q >700
>700
Solubilities (g/l) o-Dichloro benzene Chlorobenzene Aiusote Xylene Benzene Chloroform n-Octanol Methanol Acetone Dioxanc Water
14 0 72
0.37 0.37 0.041 0.01 0.11
2 10*'
1 13 t .73 3.31 0.56
0.3B
* Oeiachlorodibenzo-p-dtoxm.
various methods of destroying these compounds or detoxifying wastes in which they are contained, which are presented in other chapters in this book. More comprehensive reviews of this subject can be consulted for additional details [1-3].
TOXICITY AND HEALTH EFFECTS OF CDD AND CDF
The toxicity of chemical compounds is usually assessed on the basis of tests with animals. Frequently, in these tests, large doses of the material being tested are administered in an attempt to compress the time scale for response. This testing may result in misleading conclusions, because such massive doses are usually unrealistic in terms of the doses that would be encountered in typical real-world exposures. Moreover, since toxic response is a function of the pharmacokinetics and the adaptive charac-
MONS 22180?
244 DESTRUCTION OF DIOXINS
terittics of each particular animal system, the response of different animal species to a given chemical may, and frequently does, vary markedly. All of these considerations lead one to conclude that it is extremely difficult, if not impossible, to extrapolate toxicologic data from one animal species to another, particularly to humans. Still, animal tests are one measure of the toxicity of chemicals, and some CDD and CDF have been tested in this manner. On this basis, as shown by the comparison in Table 111 [4,5], the acute toxicities of at least some CDD [in particular, 2.3,7,8-tetr*chlorodibenzo-p-dioxin (2 J.7.8-TCDD)] are comparable to or exceed the toxicities of several well known poisons, and these rank among the most lethal chemical compounds known 10 man. It has also been observed that the LD)0 doses for various CDD isomers, based on tests with guinea pigs and mice, differ substantially, depending on the number and location within the molecule of the chlorine atom substituents (Table IV). Of the CDD isomers tested, the 2.3,7,8-TCDD is recognized to be the most toxic. The acute toxicities of CDF have been less extensively investigated, but the LDjo values for 2.3,7,8-tetrachlorodibenzofuran (2.3.7,8-TCDF) and 2.3,4,7.8-pentachlorodibenzofuran (2,3,4,7,8-PCDF) appear to be similar to those for the more toxic CDD, that is, 1-100 ^g/kg for the most sensitive animal species.
Table HI. Toatellies of Selected Folsom*
Substance
Minimum Lethal Dote
Molecular Weight
(mol/kg!
Botulinum Toxin A Tetanus Toxin Diphtheria Toxin 1.J.7.S-TCDD* Sa xitoxin Tctrodoioxin Bufoioxin* Curare Strychnine Mutcann* Diisapropylfl uorophotphate Sodium C>amde
9.0 * I01 1 0 - to1
io4
};; ri
319 757 69b 334
:io
1S4
49
3.3 m I0`"
1 0 9 |0`17 4.2 * 0-12
3 1 O'*
24 ft 10*'
25 9 52 7.2 9
1.5 9 52 9
10'* I0'7 IO'7 10* 10'*
1 6 9 I0'J
:.o 9 I0"*
'Source: Plant! and Kende [4], These data wen compiled by Mosher et al. [5], and the values indicate onlv nlativt toiieity. It should be noied that the valuet deal with different species, routes of administration, survival times and. in one cast, mean lethal dose rather than minimum leinal dote. Except where noted, administration was by ihc intnpenionatl route in mice.
*LDm on oral administration in the guinea pig.
`Intravenous iniection in the cat
MONS 221008
CHL0B0DHENZ0D10XINS AND CKLOBODIBEVZOFIBaNS 247
Table IV. Acute Toikliki of Qitorodibentodtoilnt II]
Number and Poeitlons of Chlorine Subatltoenta
______ IP (mI/>|1*
C uinorn Pip
Mkt
2.1- Di2.3.7-Tri2.3,7.1-Tetra-
1.2.3.7.1-Pent** 1.2.4.7.1-Penta* 1.2.3.0.1-Hut1.2.3.6.7.1-Heia1.2.3.7.1.9-Hru1,2.3,4.6,7,1-Htpta1.2.3.4,6.7.1.9-Octi*
>300.000 29.444
0 6-2.0
31 1.123
72 5 70-100 60-100
>600; 7.110
*AII values art for oral doses; ten period is 30 days.
>3.000 2S4 33S
>5.000 S25
1.250 >1.440
>4 . 10*
Table V, Summary of Toik Effect* of 2J.7.I-TCDD on Several Animal Species* |I,f]
Mice
Guinea rtf*
Monkeys (Female)
Thymus Involution Spleen Beductkm (white pulp) Bom-marrow Hypoplasia Liver, Mcfatocyionsi Defeneration
Bik-duct Hyperplasia Testicular Defeneration Renal-pelvis Hyperplasia Urinary-bladder Hvpcrpiasia Adrenal-cornea) Atrophy
(Zona Glomerulyi) Hcmmorhagc
Intestinal Adrenal Atcitci Cutaneous lesions
mm*
*9 * *
* -
mm
-
*
mm
*
mm mm
mm
mm
m mm
-
**m m m
** N, A
m
-
_
_i
m ***
`Kty -no effects; mildly affected; ** moderately affected: *** severely affeoed
A sununiry of the observed biological effects of 2.3.7,8-TCDD on mice, guinea pip and monkeys is presented in Table V [ 1,6]. While the
effects and their severity vary to some extent among these species, as already noted, in general the major organs affected are the thymus, liver and spleen, along with the reticuloendothelial system. Reproductive functions are also affected in some animals, and pronounced develop mental effects in offspring have been observed. In some animal species,
MOMS 221809
141 DESTRUCTION OF DIOXINS
2,3,7,8-TCDD is fetotoxic (or embryotoxic), tentogenic and even car cinogenic [1], A particularly apparent response to this compound ob served in rabbits, monkeys and man is an acnegenic eruption (termed chloracne in man).
TCDD causes marked alteration of normal enzyme activity in certain laboratory' animals. It is a highly potent inducer of aryl hydrocarbon hydroxylase (AHH), as well as the mixed-function oxidases and the cytochrome P|-450 (P-448) enzymes of the liver, lung, placenta and kidney, in mice and rats [1]. It also appears that TCDD may potentiate the adverse action of other toxic materials, or even cause another seem ingly innocuous agent to exhibit toxicity [1).
There are relatively few data concerning the distribution of CDD and CDF within animal tissues and organs or excretion of these compounds following administration. Some studies with TCDD indicate that in rats, excretion is largely via the feces, and that accumulation occurs principally in the fat and liver, with smaller a mounts in the spleen, bone, heart, lungs, testes and kidney [1], Most TCDD is apparently not metabolized by the rat, or at least metabolism of this compound occurs very slowly, and the metabolites have not been identified reliably.
Information on the effects of human exposure to CDD has been obtained principally from epidemiological studies of persons exposed as a result of accidents in chemical plants or by exposure to contaminated foods, materials or areas, A summary of the major accidents occurring in trichlorophenol (TCP) plants in the past several years is given in Table V] [7). The most notable episode involving CDD contamination in recent years was the explosion that occurred at the Icmesa trichlorophenol plant located in Seveso. July, where TCP and 2.3,7,8-TCDD were dispersed over a wide area. Approximately 5000 persons were exposed in this accident [1.2], Shortly after the accident, chloracne (a well-known symp tom of acute CDD toxicity) was observed in some 134 persons. Other disorders reported included hepatic and coronary insufficiency, chronic bronchitis, muscular weakness, irritability and nervousness, urinary and pancreatic disorders, porphyria cutanea tarda, hyperpigmentation and hirsutism and chromosomal damage. A later followup study detected peripheral nerve damage and polyneuropathy in some of the exposed individuals [2],
TCDD is also known to be an inducer of delta-aminolevulinic acid (dALA) and AHH in man. Probably this accounts for stimulation of production of eeruin porphyrins, which are ultimately excreted in the urine. The distribution of CDD and CDF within the human body and the modes of elimination have not been established, nor are the metabolic pathways or metabolites (if any) known. Reproductive effects of CDD
MONS 221810
C H LO R O D IIPiZO D IO XIN S AND C H L O R O D tiL M O R ANS 14*
Table V| Accident* In Cb<inlc*l ri*4i Maaoftrliiibit TCF (T)
11*11
1949
1951/ 1951 1931
1941/1971 I94t I9W
l*M mni 1964 IWd l70(ij 1971/ H7J 1976 Ikfmt 1976
M*md*tluirr MftMtfHO
Ncilnchc Andm und Sod*
r.bnt AO (HASH
Rhone I'udkne
Meolci
Diamond Shamrock
l'hlh|H llaphar
5poiaa
-
l>ow Uwiwral
CnalMc and Clieinic*l Ftnlncii
Dftjrcr
CltCNIIC/t Mil lento* (GniwlAn)
Itiompaon Ila)*aid
Coaatif
us
W Otinmnjr W Goman)
1 ranee
us II s
Holland Otthotk>v*l
US UR
\V Germany Awiim n*iy
us
rmannel Infuerd
117 37 ss
97* Slntf employee! Figure unknown
71 7f
3 30 IM ctlldre*
Cm* 1 AecldeiH
Omhc*iinf leading to ciplaeien during mamilactonog proccaa
Overheating leading io riploeioa
Etpoiore donn| manulacincMif prerta Overheating Overhetlmi OvtrheaMii leading < riphnioa Eipoeaie dotim nmralacluna| proccM Etpowrc dtn| n--afenuring ptoce** Ovei healing leadim I* enplane* tap--o-- doling aonaf--mmii pfuctii Eapu***** demg mamdatl *n*| pence* Overheating OvetheaMng leading in tiploemn
`lndiHlinf I) mjuri HI a IfVi eiplmmn *nd II m IW4 Source A II*)', 'Accident* in T iichloi aphorial Phdtt; A hnl For Rcaltua Survey* to AKtmli Flit I la lleaMb*. I* "Health [Hem erf llalntennled Aconwlie Itydiaeaibm**. W I Nicboboa ml J A Moot*. Ui Am* H f Ated Ai ini-TwotTt).
MOHS 221611
15* DESTRUCTION OF DIOXINS
and CDF in humans also have not been determined, in pan because of the complicating factors caused by the many other hazardous organic compounds to which man is exposed.
The most notable reported episode involving human exposure to CDF occurred in Japan in 1968 as a consequence of the accidental contamina tion of ncc oil used for cooking with polychlorinated biphenyls (PCB); subsequently, CDF were shown to be present in small quantities in the PCB [8). This incident, which has come to be known as the "yusho* incident, involved more than 1200 persons. There were several neaMerm symptoms, including chloracne. Many of these symptoms were similar to those ciied above for CDD [2]. By the end of 1977, some 31 of the exposed population had died; 11 of these were identified as resulting from malignant neoplasms of the stomach, lung, liver, breast or lymphatic sysiem, or combinations of these [2], Tissues (principally from the livers) of the victims of this accident were analyzed for CDF, as were samples of the PCB contaminant in the rice oil. A comparison of the results showed that many of the same CDF isomers were present in both the PCB contaminant and the liver tissues, and further indicated that certain CDF isomers, particularly those having all the lateral (2-, 3*. 7* and 8-) positions chlorinated, were preferentially retained in human tissues [8], This is one of the few instances in which such compounds have been implicated unquestionably in severe human health effects.
In several animal studies, PCB have been implicated as inducing toxic effects in animals, but in some of these investigations, it has not been dear to what extent PCB were contaminated with CDF, and the causative agent or agents are therefore uncertain.
SOURCES AND ACCUMULATION OF CDD AND CDF IN THE ENVIRONMENT
As mentioned earlier, major sources of CDD and CDF detected in the environment are industrial chemicals. More recently, however, it has been recognized that these compounds are present in the effluents from various combustion processes. The principal environmental sources of CDD/ CDF thus far identified include [1]:
). chemical product! for which the normal manufacturing proem |C!untct these compound! ai byproduct!, and which are widely uwd in the environ ment (peiucidet, wood-trtiun| product!, etc.);
2. uncontrolled manufactunnt proceitei, which remit in reteam of CDD and CDF texplonoiM of rcacton).
MOMS 221812
chlorodibenzodioxins and chlorodibenzofurans :si
J, improper disposal of chemical manufacturing wattes or products containing
CDD and CDF ('landfills, waterways);
4. indneraiton of municipal, commercial and industrial ist: 3. ordinary combutuon processes (wood-burning and others); and 6 accidents (fires, spills, etc.).
Perhaps most important among the mass-produced chemical* which are known lo be contaminated with CDD and CDF are the orthochlorophenols. particularly TCP and pentachlorophenol {PCP). TCP has been used widely as a preservative, bactericide, fungicide and aljicide in many industrial products, and is the starting material used in the manu facture of a series of industrial and agricultural chemicals, notably the herbicide 2.4.5-T, and the related products, silvex. ronnel and hexachlorophene. a baciericide. PCP is extensively utilized in wood-preserv ing processes. CDD and CDF that have been detected in various chloro phenols and related pesticide products are listed in Table VII. The probable mechanism by which chlorodioxms are formed in the synthesis of orrho-chlorophenols is a thermally induced condensation reaction of two molecule* of the sodium or potassium chlorophenate, such as that exemplified in Figure 2 for the production of 2,3,7,8-TCDD in the manu facture of 2,4,5-TCP. A so-called "predioxin," a phenoxyphenate or substituted diphenyl ether, may be an intermediate in this reaction. Similar condensation reactions can account for the formation of hexa{HxCDDJ, hepta- (HpCDD) and octachlorodibenzo-/?-dioxms (OCDD) in the manufacture of PCP (Figure 3).
The extensive occurrence of CDD and/or CDF in such widely used commercial chemicals as chlorophenols, their derivatives and PCB provides a clear indication of the need for adequate methods for destruc tion of chemical wastes and related materials that result from manu facture of these chemicals. Obviously, improper disposal of such chemical wastes can lead to extensive environmental contamination. Prominent examples of this that have received recent attention are the Love Canal area in Niagara Falls, New York, where several major chemical dumps are located, and a 2.0-T/2.4-D manufacturing plant site located in Arkansas. Levels of TCDD typically found in environmental samples from these sites are shown in Tabte VIII. Applications of excessive quantities of herbicides contaminated with TCDD, as in South Vietnam during the conflict there and at various military sites in the United States during this period, or the contamination of the environment resulting from such events as the TCP reactor explosion at Seveso, Italy, can also result in elevated levels of TCDD in plants and animals (including humans) present at such sues (Table IX [9]).
As already noted, CDF are also present as contaminants in some PCB
HONS 221813
m DESTRUCTION OF DIOXINS
lalilt VII. Ulghtr f hfewMMbtiirtMlInilin Mill ami ( WormllhfufofnfiBt CDF llilnlrf In Oilnmphtimh iirf ItliM FntltWt* [I.I|
(.1)1) PflKltd'
CDF OrttUN'
f'ffwtwrl
iiiii-
Omm
rrci-
flrpU*
Otfv*
Trlffc
ri-
icr 1 ci * h ItH pbcml l-c 1' J.t.M SilK* J,l>`
1 ibon Semite
_ _ - a.
4 --
t * o
4
Nl)
-
-
4 NO
.
.
.
- Nl)
4
-
- Nl) Nl)
< 4
. 4* --
ND NO ND NO
a. ND ND , Nl) NO
to`tuntrfltdlMm rin|(i *< : Mil ppw * 0.J-
ppm; - * <0. ppm. ND 1 not dtietmintl.
`Htrtnt amljKi Jtj Wr<|lH Stilt Untwnljr.
Una-
It ND ND
* ND ND
llrpll'
4 44 44 ND ND
ND NO
Otlt-
4 4* ND ND
ND ND
MOMS 221814
CHLORODIBENZODIOXIS5 AND CHLORODIBENZOFl'R ANS 153 2,*|5 T
Cl Cl
2,S,T,6 -TCPD Fi(ur I. Reactions involved in lymhcsit of 2,4.5-inehlorophcnol and rtUted product!
(2.4J-T and denvmiiws) showing formation of 2.3.7.1-TCDD at a b>-product.
formulations [2]. In addition, it is known that pyrolysis of PCB at certain temperatures (obviously lower Ulan the temperatures required for com plete destruction) yields CDF as products [3]. The reaction scheme for formation of CDF from pyrolysis of 2,2\4,4',5,5'-hexachlorobiphenyl, for example, is as shown in Figure 4. An instance in which a PCB formulation (also containing hexachlorobenzene) was incinerated under conditions leading to formation of substantial quantities of CDD and CDF occurred in Binghamton, New York. This episode occurred as a
MOMS 221815
IH DESTRUCTION OF DIOXINS
(PCP)PENTACHLOROPHENOL
PCP, NoSolt ----------------------
ocoo
Fi|art J. Rueuotu involved in synthesis of PCP and dtrivaiivu showing formation of
octtchlorodibtniodioxin s t b\-producv result of * transformer fire in the basement of a large office building. Soot samples and wipes of surfaces in nearby areas showed rather large concentrations of CDD and CDF, as indicated by the data shown in
MOMS 221816
CHLORODIBENZO DIOXINS AND CHLORODIBENZOFL'RANS 2SS
Table VIII. Unk of TCDD in I arlma Environmental Riolo|kal Samples AmIjiH by the Breton UbwiHKy of
Wright Sut* Usilveraity
Sample Description
Native TCDD Deteeled
Haurdoiu title landfill soil/sludgt. New York itate
Tnchlorophenol manufecturms ante. still bottom, Arkanui
Blood ample from workers involved in cleanup of orrAo^Morophtnolspillin tank car derailment, mtssouri
Blood ample from Vietnam veteran Bovine Municipal rcfuK-firad incinerator.
New York mate (on particulate emissions) Soot from wood-burning fireplace
Agent Orange 2.4D (several manufacturers)
300-199.000 ppt
22.000 ppt
7-2* ppt 41 ppt 10 ppt
13 mg/hr 0 65 ppb 0.1-60 ppm 0.2-1.3 ppb
Table IX. TCDD Levele to Wildlife to Straw, Italy, Area FoBowtog TCP Accident*
Animal
No. of Samptee Analyzed
Field Mouse Hare Toad Snake
14
5 1 t
Earthworm*
Tisane
Whole body Liver Whole body Liver Adipose tissue Whole body
Positive
14/ 14 3.'5 i; 1 i/i
r:
TCDD Level (ng/g)
Average
Range
4.5 0.07-49 7.7 2.70-13 0.2 2.7 16.0 120
'Source: Fanelli ct al. [9], referenced in Esposito ei al. {I}. 11 Each ample repratnu a 5*g pool of earthworms.
Table X for a wipe sample [10], In still another instance, incineration of wood-treatment wastes containing PCP, and probably related CDD/ CDF or precursors of these, in an incinerator that apparently provided less-than-optimum conditions for destruction, yielded ash residues con taining relatively large quantities of CDD/ CDF (see Table XI). Another chapter in this book [ 11] presents a more detailed discussion of the recent assessment of destruction of PCB by incineration under conditions where
MOMS 221817
2tt DESTRUCTION OF DIOXINS
Cl Cl Cl Cl
Cl Cl
1,3,4,7,8`pentO' COF (proposed)
Flfrt 4. Reaction* leading to formation of CDF from pyrolysis of 2J'.4.4\3J'-twxoehtorobiphepyi.
high destruction efficiency was achieved and the level of CDD/CDF in the combustion effluents were within limits which the U.S. Environ mental Protection Agency (EPA) deemed acceptable.
ANALYSES OF CDD/CDF IN ENVIRONMENTAL SAMPLES
The extraordinary toxicity of some CDD and CDF dicutes the need for analytical capabilities that can detect and quantify picogram quanti ties of CDD and CDF. At the same time, great analytical methods specificity is required, because several other prominent conuminants that persist in environmenul samples (e.g., PCB and DDE) can interfere with the determination of CDD and CDF. The analytical capability described has only been realized within the past 3-4 years, and it is now possible to reliably determine parts-per*trillion levels of CDD and CDF in many
MOMS 221818
CHLORODIBENZODIOX1NS AND CHLORODIBENZOFURaNS 231
TaMa X. R--te tf HRCC/LRMS Analytb f W|p* Sawpk froM Ana CoataMnatad By TruitfonMr Fin far Tatra- Tfcraagh OcttcMwIaiMf Dikmif4lailai uf DhMuteiM
CDD/CDF* Apperiwt ItOHMn*
TCDD
ND
QaaSl; of CDD/CDF Dttactad
(ng/tpt)
ND
MMourn DtoctaMt Qoratltr
(ag par bowor)
0,10
FCDD
ND
ND 0.10
HxCDD
ND
ND 0.20
HpCDD
I.2JA6.7.9-
Total nCtrUJ,<.t.7.l-
0.63 0.43 l.l
0.20 0.2Q 0.20
OCDD
I.2J.4.6.7.I.9,TCI,-OCDD
1.0 0.20
TCDF
IJZ.4.S-
2J.6.I2J.7.1Otter bomtis (1) Total
2.0 3.1 9.6 33.1 50.4
0.10 0.10 0.10 0.10 0.10
PCDF
t .2.4.7.*Otter botnm (13) Total
12 tlJ 17.0
0.10 0.10 0.10
HxCDF
1X4.S.7JOtter boom (12) Total
1.6 43.6 453
0.20 0.20 0J0
HpCDF
OJ.4.4J.9Otter boom (4) Total
2.7 4.6 7J
0.20 0.20 0.10
OCDF
OJ.4.6.7.1.9-
7.3
OJO
*FCDD * panta-CDD: HxCDF bexa-CDF; HpCDF tepta-CDF; OCDF ocia-
CDF.
kS*t taxi for dimano*.
types of cnvironmentBl and biologic*1 samples, hazardous chemical wastes, and chemical formulations. The Brehm Laboratory. Wright State University, has been one of the major contributors to the development of this highly sophisticated analytical methodology. In general, the ana* lyrical procedures now applied for definitive determinations of CDD and CDF isomen entail the following;
HONS 221*19
251 DESTRUCTION OF DIOXINS
TaM XI. HRCC/LRMC Analytic*! Remits for CDD/CDF ill Ash Sample from lnctiwralioN f Wmn Containing PCP*
CDD/CDF
Total Number of Appnwnt Itomert
Total Dittol (n|/|)
Minimum Detectable C<*K*tr*i*4
(n|/|)
MCDF DCDF
3 s
73 0.1 23 0.3
TrCDF
t
13 0.0
TCDF
7
7 0.3
PCDF
J
1I
HxCDF
J
3I
HpCDF
2
61
OCDF
1
21
MCDD
1
J 0.1
DCDD
4
5 0.3
TrCDD
3
2 0.6
TCDD
4
4 0.2
PCDD
3
32
1
HxCDD
5
II
1
HpCDD
2
117
1
OCDD
!
191
1
`Recent anaiym by Wright Sun* University.
1. extraction of CDD and CDF from the tunpic matrix oriaf organic MlvcnU, 2. preliminary Kparaiiofl of CDD and CDF from other constituent! of Iha
matrix, which aho hove bean extractad (including other chlorinated matarialal tiling aetd-bau treatments and la^iaid chromatography with alnmina, silica gal and/or other aniiaMe cotamm: 2, further fractionation of the CDD and CDF tning normal and revcnc-phtm high-performanca iigutd chromatography (HPLC): and 4, analyeci of the prepared extract* containing CDD and CDF tning capiUarycehnm gat chromatography/maxs ipearometry (GC/MS). Both low- and high-resotuiioa man spectrometry may he uted in thit anaiym, depending on the taoiple.
The application of this complex analytical procedure is tedious and costly, but such a procedure is necessary to obtain definitive data on the CDD and CDF isomers at the extremely low (paru-per-trillion) concen tration levels at which these must be detected. The results of such an analysis are well illustrated by data obtained from analysis of the ssh sample resulting from incineration of PCP wood-preserving process wastes, which are shown in Table XI. Interestingly, the TCDD isomen detected in this sample were 1,3,6,8,- 1,3,7,9-, 1,3,7,8- and 1,2,3,4-TCDD,
MOWS 221820
CHIORODIBENZO DIOXINS AND CHLORODIBEN'ZOFVRANS 2>
No 2,3,7,8-TCDD was found. Similar analyses have recently been accomplished by the Brehm Laboratory on suck effluents from indneration of municipal refuse, and on effluents from indneration of wastes conuining PCB. The latter work is discussed more fully and the deuiled analytical techniques are also described in another chapter in this book [11].
ENVIRONMENTAL TRANSPORT AND NATURAL DEGRADATION OF CDD
Considerable work has been done in an effort to assess the extent of degradation and transport of CDD in the environment [1], although the conclusions from these studies are not entirely clear. Although bio* degration of TCDD does not seem to be a particularly important process, both TCDD and OCDD appear to be effectively photodegraded by both natural sunlight and artificial ultraviolet (UV) radiation [1], Transport of TCDD in soil, water and air has been investigated, but since the results depend on so many environmenul factors (e.g,, type of soil and organic content, temperatures and organic content of water, and method of dispersal in air), the conclusions are not straightforward. It appears, however, that TCDD can migrate to some extent in soils, especially porous, sandy soils. Transport of CDD/CDF can occur in the air, especially if these compounds are sorbed on airborne particulates. It is also clear that transport of CDD/ CDF can occur by runoff of surface waters and or leaching into groundwaters, which ultimately may con taminate lakes, rivers and streams. In the latter instance, TCDD appears to accumulate largely in sediments, although the content of other organic compounds in natural waters also affects the concentration of CDD/ CDF therein. Finally, as discussed earlier, CDD/ CDF can bioaccumulate in some plants, animals and fish exposed to these compounds; obviously, this may also result in transport end, ultimately, dispersion of these compounds in the environment. There are few baseline data on con centrations of CDD/ CDF in the environment, however, except where high levels of CDD/ CDF are anticipated because of massive contamina tion episodes such as those described earlier
DESTRUCTION OR DETOXICATION OF CHEMICAL PRODUCTS AND WASTES CONTAINING CDD/CDF
Among the methods applied in attempts to destroy or detoxicate wastes conuining CDD and/or CDF are conventional incineration, photolysis.
HONS 221B21
2M DESTRUCTION OF DIOXINS
radiolysis, ozonolysis, catalytic dechlorination and biological treatment. Several of these techniques and their application to such chlorinated compounds are discussed in more detail in several other chapters in this book. These chapters clearly demonstrate that considerable success has been achieved in devising environmentally acceptable methods for de stroying or detoxifying hazardous wastes containing CDD and/or CDF.
REFERENCES
1. Esposito, M. P., T. O. Tiernan and F. E. Dryden. 'Dioxins," U.S. EPA Report EPA-600/ 2-80-197, Industrial Environmental Research Laboratory, Office of Research and Development, Cincinnati, OH (1980).
2. Nicholson, W. J.t and J. A. Moore. Eds. "Health Effects of Halogenaied Aromatic Hydrocarbons,' Ann. N.Y. Acad. ScL 320:1-730 (1979).
3. Joint N1EHS/1ARC Working Group. 'Long-Term Hazards of Polychlo rinated Dibenzodioxins and Polychlorinated Dibenzofurans," World Health Organization/ International Agency for Research on Cancer, Lyon, France (197*).
4. Pland, A., and A. Kende. "2,3.7.8-Tetrachlorodibcnzo-p-Dioxin: Environ mental Contaminant and Molecular Probs," Fed. Free. 35(12):2404 (1976).
5. Mosher. H. S., F. A. Furhman, H. D. Buchwald and H. 0. Fischer. Science 144:1100-1110 (1964).
6. Moore, J. A., and R. E. Faith. "Immunologic Response and Factors Affecting Its Assessment," Btviron. Health Perip. It: 125 (1976).
7. Hay, A. "Accidents in Triehlorophenol Plants: A Need for Realistic Surveys to Ascertain Risks to Health," Ann. N.Y. Acad SeL 320:321-324 (1979).
8. Rappe, C, H. R. Buser, H. Kuroki and Y. Masuda. "Identification of Poly chlorinated Dibenzofursns (PCDFs) Retained in Patienu with Yuaho," Chemosphere 4:259-266 (1979).
9. Fanelli, R. "Presence of 2,3.7,8-Dibenzo-p-Dioxin in Wildlife Living Near Seveso, Italy: A Preliminary Study," Institute de RJcerthe Fannacologkhe "Mario Negri." Milan, Italy (19*0).
10. "Determination of Chlorinated Dibenzo-p-Dioxins and Dibenzofursns in Surface Wipes and Related Specimens from Broome County Facilities, Binghamton, NY, Contaminated u a Result of a Transformer Fire," Brehm Laboratory, Wright State University (1981).
11. Tiernan, T. O., M. L. Taylor, J. G. Soldi, G. F. Vanness, J. H. Garrett and M. D. Porter. "Incineration of Chemical Wastes Containing Polychlorinated Biphenyls: Assessment of Tests Conducted at Rollins Environmental Services, Deer Park, Texas, and Energy Systems Company, El Dorado, Arkansas," Chapter 9, this volume.
MOMS 221*22
CHAPTER 16
SELECTED LEGAL ASPECTS OF A DIOXIN DETOXICATION PROJECT
Kent A. Stormtr Syntex (U.S.A.), Inc. Palo Alto, California 94304
On a summer afternoon in 1974, Godfrey Moll, Plant Manager of the Syntex Agribusiness chemical production facility in Verona, Missouri, rapped on the side of an old 20-foot-tall steel tank, which had been sitting idle on the premises for many years. Syntex had purchased the plant, including the steel tank, in 1969. Moll assumed that the tank was empty because Syntex had never used it, but his knocking on the tank wall was inconclusive. Consequently, he carefully lowered a small flask into the tank and, to his surprise, it came up filled with a dark sludge material. Moll calculated from the size of the tank that it contained approximately 4300 gallons of this material, which was the consistency of heavy motor oil. Laboratory analysis of the sludge increased his surprise considerably: the 4300 gallons of sludge contained approximately 343 ppm of dioxin.
It soon became evident what had happened. In the late 1960s North Eastern Pharmaceutical and Chemical Company, Inc. (NEPACCO) leased a` portion of the Verona plant from the company that then owned it. Under this lease, NEPACCO was entirely responsible for disposing of its own wastes and trash, and agreed to operate at all times in conformity with applicable laws and regulations. NEPACCO's activities at the plant included the production of hexachlorophene. One step of that manu facturing process, which involved the purification of trichlorophenol (TCP), apparently produced dioxin as an unwanted by-product
261
HONS 221823
i DESTRUCTION OF DIOXINS
Syntex Agribusiness later acquired the Verona plant subject to the existing lease with NEPACCO. NEPACCO ran into financial difficulties when hexachlorophene, its main product line, was essentially removed from the market by the Food and Drug Administration (FDA) and soon thereafter NEPACCO allowed its corporate charter to lapse.
In short, in violation of its lease, NEPACCO had apparently simply abandoned the dioxin-containing wastes in the tank and, after Syntex purchased the facility, had gone out of business.
The first-priority activity, from legal as well as other perspectives, was to provide additional safety precautions for the tank. A reinforced concrete dike, capable of containing the entire contents of the tank should it leak, was constructed beneath it; a building was erected over it; and a wire fence was put up around it. After the area was safely secured, Syntex turned its attention to finding a suitable way to resolve the problem.
The overriding consideration for Syntex in searching for and selecting a disposal method was the safety of the public, its employees and the surrounding area. Syntex was disappointed many times in its search. Several plans for disposal by incineration at appropriate facilities had to be abandoned because Syntex was not allowed to transport the wastes across state lines. At one point, the possibility of incineration at sea on the ship Vulcanus was also explored. This option met with two main obstacles: the unwillingness of state and federal authorities to allow transportation across state lines and the unwillingness of the Vulcanus to handle what it viewed as a small quantity of waste. In general, as the hazards of dioxin became more publicized, fewer and fewer consultants or contractors were willing to become involved in the disposal of this material. However, despite these difficulties, Syntex continued to search for a disposal method, and began exploring the possibility of detoxicating the NEPACCO wastes onsite.
INTERDISCIPLINARY EFFORTS
Early in 1978, Syntex entered into a contract with IT Enviroscience (formerly known as Dow/ Hydroscience) to undertake a three-phase program. Phase I was a technology review by IT Enviroscience to discover feasible methods of onsite reduction and recommend a method for further development; phase 11 involved laboratory development and refinement by IT Enviroscience of the method which they recommended; and phase 111 was the detoxication of the NEPACCO wastes.
Syntex convened a Blue Ribbon Committee to make an independent evaluation of the IT Enviroscience recommendations and to guide its
HOMS 221B24
LEGAL ASPECTS OF DIOXIN DETOXIFICATION
progress in this endeavor. The Committee consisted of S academic and industrial experts in photochemistry, chemical engineering, process anal* ysis and reaction kinetics. When it became evident that the process that IT Enviroscience was likely to recommend would involve photolysis, two experts in this specialty were immediately added to the Blue Ribbon Committee.
Syntex also, of course, continued to apply intensively the expertise of its own employees in many disciplines. They included chemical engineers, civil engineers, process engineers, research chemists, analytical chemists, industrial hygienists, toxicologists, physicians, insurance specialists, fire protection specialists and lawyers.
As I have stated, safety of the public, its employees and the surrounding area was Syntex' primary consideration. TTii* consideration weighed heavily against any process requiring operation at high temperatures or pressures. The process ultimately proposed by IT Enviroscience was extraction of dioxin from the NEPACCO wastes followed by ultraviolet (UV) photolysis of the extractant material. The process had the advan* tages of operating at essentially ambient pressures and temperatures, as well as being amenable to batch processing, which enabled careful regulation of the amount of wastes being treated at any given time. The proposed process was reviewed and approved by the Blue Ribbon Committee in 1979.
WHY LAWYERS?
On the surface, the destruction of these wastes appears to be more a scientific than a legal challenge. There was no litigation pending nor even threatened concerning these materials. Why, then, were lawyers an integral part of the team?
The involvement of legal counsel began very early in the detoxication project, in fact, at the point of decision as to whether there was even going to be such a project The initial question was whether to focus efforts on - pointing out Syntex' lack of responsibility for the presence of the materials or, instead, to turn directly to an attempt to clean them up.
On one hand, Syntex had not generated or disposed of the wastes in question. NEPACCO, which created the wastes and abandoned them at the Verona chemical plant nine yean before, was out of business and had not existed as a corporation since 1974. Syntex found itself involved in this matter because it purchased the plant in Verona from another company, which had earlier leased pan of the plant to NEPACCO for the manufacture of hexachlorophene. Clearly, a strong basis existed for
HONS 221*2*
2*4 DESTRUCTION OF DIOXINS
declining any responsibility whatsoever, on the grounds that Syntex did not generate the hazardous materials or place them in the tank.
On the other hand, militating in favor of Syntex* attempt to detoxicate the materials created by others was a factor that was and continues to be of paramount importance to Syntex: safety. Syntex evaluated the com* parative safety (and attendant legal exposures) involved in processing the materials vs leaving them where they were, in a protected steel tank. Even though the wastes were protected in their tank, with its dikes and fences, they still might be affected by such events as tornados, deliberate damage or leakage due to eventual deterioration of the tank. They were, in the final analysis, located on what had become Syntex property and the company felt an obligation to deal with them.
Another important factor weighed very heavily in the decision to proceed to detoxicate the materials: Syntex wished to act as a good corporate citizen and to alleviate a possible source of concern and anxiety both in the community in which its plant was located as well as in surrounding communities. Accordingly, it was decided to seek a way to detoxicate the materials.
Of course, involvement of lawyers in the project did not cease once the decision was made to detoxicate the sludge. During process development and before startup, lawyers were active in a number of areas. First, considerable effort was expended on maintaining liaison and rapport with responsible officials of the U.S. Environmental Protection Agency (EPA) as well as state and local agencies. As a part of this liaison activity, lawyers often served as problem-solvers to help avoid and overcome possible impasses and to help gather and synthesize information from the various disciplines in a manner that would be responsive to EPA's concerns. For example, numerous meetings were held as the development of the process progressed, to keep EPA officials in Washington, DC, and the Regional Office in Kansas City informed. As the process was selected and refined, specific documentary submittals were provided. At one point, 17 multifaceted written questions were posed by EPA. A four-inchthick, item-by-item response by Syntex elicited an even larger number of questions from EPA. Soon, however, the questions began to decrease in both number and scope until finally, on May 19, 1981, EPA authorized Syntex to begin processing. The actual commencement date of the processing took place only two weeks later than the startup goal that Syntex had set almost a year before. Syntex feels that the timely startup of this process provides a good example of the kind of results that industry end government can accomplish by working cooperatively together.
MOMS 221826
LEGAL ASPECTS OF DIOXIN DETOXIFICATION :*5
In a second, related, area, there was considerable legal activity involved in obtaining the requisite federal, state and local permits. For example, approximately 55 days before processing was scheduled to begin, a regulation was promulgated under the Toxic Substances Control Act (TSCA) requiring 60-day notice to EPA before any dioxin disposal could commence. The regulation was actually designed to halt another com pany's dioxin disposal project, which EPA apparently thought ill advised. Unfortunately, the regulation's prohibitions reached beyond that one company and, at least literally, encompassed Syntex' proposed process ing. After extensive negotiations and correspondence, EPA again coop erated with Syntex by finding that the notification requirement had been met, partly on the basis that Syntex had been keeping EPA informed for several years of its progress toward detoxication. Again, the spirit of cooperation and openness between Syntex and EPA had made it possible to overcome a problem that otherwise might have halted or delayed the project.
A third area of legal activity involved the protection of confidential proprietary process information. The contract with IT Enviroicience obligated Syntex to maintain certain process information as confidential. Yet EPA felt it could not approve the process without such information. Considerable negotiation and correspondence enabled a mutually satis factory resoluu'on of these competing needs.
A fourth area of legal activity involved the preparation of contracts with IT Envirosdence, the Blue Ribbon Committee members and other consultants. The sensitive nature of the project and the involvement of confidential process information made the task particularly challenging. Another group of issues requiring the application of legal effort involved establishing shutdown authority, emergency procedures and EPA repre sentation at the processing site. Finally, considerable time was spent coordinating public involvement, including town meetings, press confer ences and briefings of officials, including the mayor of Verona and U.S. senators.
During the successful operation of the detoxication process, input by lawyers continued along lines similar to those described above, par ticularly in the areas of maintaining liaison with EPA and coordinating the efforts of consultants. Fortunately, the process operated with a minimum of hitches, so no further legal activity was necessary with regard to such issues as shutdown authority or emergency procedures.
HONS 221827
:m destruction of dioxins
LAWYERS' INTERACTION WITH OTHER DISCIPLINES
One way to conceptualize the lawyer's role in such situations is to say that he or she can be responsible for removing or addressing certain obstacles and problems so that scientists and other experts are allowed to focus their expertise on resolving the scientific and technical aspects of the situation. Prime examples of this traditional role for a lawyer might include obtaining permits and drafting contracts. These activities repre sent an important aspect of a lawyer's traditional role in such situations. Conceptualizing the interaction among the disciplines in such a limited fashion, however, vastly undervalues the extent of symbiotic interplay that is essential to the success of such a project. The several disciplines involved did not simply work on separate, parallel tracks. Instead, many key decisions involved a collegial process that brought together several areas of expertise, including legal. One example may help illustrate this point.
The design of environmental and personnel sampling protocols and the selection of the accompanying analytical methods required an extensive iterative dialog among lawyers, analytical chemists, industrial hygienists and others. Such a system had to meet several conflicting demands. On one hand, the samples had to be sufficient in number to rebut alleptions of dioxin release or injury, have sufficient sensitivity to meet legal standards and be frequent enough, with short analytical turnaround times, to enable rapid identification of any problems. On the other hand, these environmental sampling and analytical efforts could not be so numerous, sensitive or frequent as to interfere with the analysis of process samples, prolong excessively the turnaround time, extend the duration of the detoxication processing, or increase unacceptably the possibility of obtaining misleading false positive results. The pooled expertise of several disciplines, based on extensive discussion, was necessary to balance these variables.
Unfortunately, shortly before the detoxication processing was com pleted, another NEPACCO dioxin disposal site was discovered in a trench on a Missouri farm several miles from the Verona plant. Once again it was decided to clean up the materials rather than to focus efforts on pointing out Syntex* lack of responsibility for the presence of the materials. Based on the lessons of the Verona detoxication effort, another interdisciplinary team, including lawyers, was assembled, and a plan for site cleanup was approved by EPA. The cleanup effort at this new site is now well underway.
HONS 221828
LEGAL ASPECTS OF DIOXIN DETOXIFICATION :47
In retrospect, Syntex' efforts to ict in t responsible manner and as a good corporate neighbor have been well received. A U.S. senator for the state of Missouri, after being personally briefed in Washington about Syntex' proposed detoxication effort, commented that the program "represented the highest degree of corporate care and concern." The Chamber of Commerce for a nearby town passed a resolution thanking Syntex for its "caring attitude . .. and moral and unselfish stance." Finally, Douglas M. Costle, then the head of EPA. traveled to Missouri to hold a press conference complimenting Syntex for its "responsible and constructive actions." Comments such as these helped confirm that the correct choice had been made more than seven years earlier to tackle this difficult hazardous waste disposal problem.
HONS 221829
CHAPTER 17
PROCESS FOR DESTROYING TETRACHLORODIBENZO-p-DIOXIN
IN A HAZARDOUS WASTE
J. H. Exntr, J. D. Johnson, 0. D. Irim, M. N. Win and R, A, MUIor
IT Envirotcience Knoxville, Tennessee 37923
Polychlorinated dibenzo-p-dioxins (PyCDD) are extremely toxic com* pounds [1,2] that have been involved in several highly publicized acci* dents such as the Missouri Horse Arena episode in 1971 [3], the Seveso release in 1976 [4], and in the controversies surrounding the use of Agent Orange and trichlorophenoxyacetic acid herbocides. The 2,3,7,8-ietrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) isomer is one of the most toxic chemicals known toward certain species of animals. In 1974. the presence of tetrachlorodibenzodioxins was confirmed in a waste storage tank at a chemical plant in Verona, Missouri. The waste resulted from production of hexachloropbene by North Eastern Pharmaceutical and Chemical Co. (NEPACCO). NEPACCO became defunct in 1971 and the tank and contents reverted to Syntex (U.S.A.) Inc. After the discovery of the contents of the tank, public and political opposition to transportation and destruction of this politically sensitive waste prevented land* or sea-based incineration. Consequently, IT Enviroscience was retained to examine treatment options for this waste that could be used at the plant site. The objective was to decrease the hazard of the stored waste to the surround* ing community of Verona, Missouri, by developing a safe, effective method to reduce the approximately 7 kg of dioxin in about 4600 gal of waste.
269 MONS 221830
J7S DESTRUCTION OF DIOXINS
Development of the destruction process and the ultimate destruction of the wste involved a three-phase project that illustrates the social, economic, political, technical and le|tl aspects of waste detoxication projects. In addition, this project illustrates the multidisciplinary nature of the technical solutions to these difficult waste problems. The technical solution relied on the experience of analytical, organic, physical and inorganic chemists; chemical, civil and process engineers; industrial hygienists and toxicologists; and medical personnel.
EXPERIMENTAL
Safety, Health and Environmental Considerations
TCDD is teratogenic, hat a high acute toxicity, and causes severe chloroacnogenic response on skin contact [5]. Work was carried out in an isolated work area in accordance with safe handling recommendations [6]. Standard laboratory emergency procedures were altered to separate potentially contaminated apparatus and personnel from the rest of the laboratory. Skin contact was minimized through the use of disposable coveralls and rubber gloves. Goggles and face shields were worn during nonroutine laboratory manipulations. Personal hygiene was enforced by requiring showers and clothing changes when workers left the isolated work room. Chemical manipulations were carried out in a well ventilated hood. The minimum air velocity at the face of the hood was 100 ft/min, and under normal working conditions the velocity ranged 150-200 ft/min. Liquid and solid wastes were placed into a plastic bottle. Glassware was placed into metal cans. Slightly contaminated materials, such as gloves and towels, were placed into a 55-gal drum. Used coveralls were placed into a second drum. These drums were sealed and disposed of by incineration.
All persons working with TCDD were given complete baseline physi cals, with special attention given to liver function and skin condition. These physicals were followed semiannually for a minimum of one year after completion of the project.
Analytical
Gas chromatography (GC) analyses were carried out on a HewlettPackard 5750 with Hame ionization detection (FID). A 10% OV-101 on
HONS 221831
DESTR0V1NG TCDD IN HAZARDOUS WASTE 171
80/100 mesh Chromosorb WHP glass column, 10 ft 2 mm. was used at 230C. Nitrogen flowrate was 30 ml/min; detector temperature was 270C, injector temperature was 230C, and the sample volume was 2 pi. TCDD retention time was 9.5 min.
GC/ electron capture detection (ECD) analyses were carried out on a Hewlett-Packard 5710 with a *JNi detector. A 1.5% SP-2250/1.95% SP 2401 on Supelcoport 100/120 glass column, 6 ft 2 mm, was used at 220C. Carrier flow (5% methane/95% argon) was 20 ml/min, detector temperature was 330C, injector temperature was 250C, and sample volume was 1 pi using an autoinjector.
High-pressure liquid chromatography (HPLC) was carried out on a Perkin-EEmer LC-55 using a 250 6.2-mm Zorbax ODS column (Dupont) at 50C. The eluent was methanol at 2 ml/min. The UV detector was set at 235 nm, connected to a recorder deflecting full scale at 0.01-0.02 absorbance units-
GC/mass spectrometry (MS) analyses were performed on a Finnigan Model 3200 coupled to a System Industries 150 data package, which permits continuous acquisition during chromatography. Analyses were carried out with a 6-ft 2-mm glass column packed with 3% OV-101 on 80/100 mesh Chromosorb WHP. Conditions for qualitative analyses were: 120C for 2 min, 120-250* C at 8*C/min; injector, 290* C; separa tor, 290*C helium flow, 30 ml/min; sample volume 2 pi. Quantitative analyses were carried out isothermally at 250* C,
Isopropyl alcohol (IPA) in hexane was analyzed on a Perkin-Elmer Sigma 3 FID, using an 8-ft * !4-in, 100/120 mesh Porapak stainless steel column. The column temperature was 150*C; detector, 200* C, injector, 200*C end the Nj flowrate was 25 ml/min. Ultraviolet (UV) spectra were obtained on a Perkin-Elmer 202 Ultraviolet-Visible Spectrophotometer.
Materials
Solvents were obtained from Burdick and Jackson (distilled in glass) or Fisher HPLC grade. Alumina was Brockman activity 1.80-200 mesh or Fisher A-540. Silica gel was Fisher ACS reagent, 100-200 mesh. NEPACCO waste was hand-delivered to the Knoxville laboratory.
TCDD Standard
TCDD (>99%), 6.1 mg, obtained from the Dow Chemical Company, was transferred quantitatively into a 50-ml volumetric flask. The solid was dissolved in o-xylene. Triphenylethylene (Aldrich) in o-xylene was
HOMS 221832
172 DESTRUCTION OF DIOXINS
added as an internal standard at 21 mg/1. Dilutions were made volumetrically and standards were stored in septum bottles sealed with Teflon*lined caps and covered with aluminum foil.
Column Chromatographic Purification of TCDD Samples
Several procedures were used throughout the course of the work:
1, Buw alumina. 4 0 g. was added lo 4 ml of hexant in a I- tO-em flail column. To a J,0*ml aliquot of a hexane extract of ihe NEPACCO watte. 7t 2 mg/1 (336 Mt) TCDD was added, and the hexane wax collected. A 20*ml aliquot of 2% v/v methylene chloride/hexane was placed on the column and collected. No TCDD was detected in this fraction. TCDD was eluted with a 20-ml ponton of 30% methylene chloride/ hexane, and the solution was concentrated to 6.3 ml (4.4 g). TCDD concentration was 36 mg/1, 332 pg. a recovery of 991k
2. A l* > 10-em column was packed with 1.0 f of silica gel and 4.1 f of 44% w/w lulfuric actd/ailiea gel A second column. I 30 cm, was packed with 6.0 g Fisher A-540 alumina, which had been activated at I30*C for 20 hr. A small layer of anhydrous sodium lulfatt was placed upon the alumina. The photolysis residua waa reduced in volume by about 2.0-2.5 timet. To this concentrate was added 260 jil of 66-mg/1 solution of TCDD in hexane. Analysis by CC/F1D gave 9 mg/1 TCDD in the spiked solution. A 2.0-ml aliquot was placed on the acidic silica gel, and the material was eluted directly onto the alumina column with 43 ml of hexane. The alumina column was
. eluted with 20 ml of 30% v/v methylene chionde/hexane. The solvent was evaporated to dryness in a 3-ml cone-bottom vial and dissolved in 2 ml of hexane. A 100-fold dilution of this sample gave 7.2 ug/1 (17%) of TCDD by CC/ECD.
Analyst! of NEPACCO Waste Extracts
Into a 125-ml separatory funnel was placed 8.04 g (`'5.8 ml) of NEPACCO waste, then 30 ml of 15% w/w aqueous sodium hydroxide and 30 ml of hexane were added successively. The mixture was shaken for about 30 sec, and the separated, lower, black aqueous phase was added to a second 125-ml separatory funnel. The volume of the hexane layer was determined with a graduated pipet, and the hexane layer was analyzed by GC/FID. The caustic layer was extracted five more times with 30-ml portions of hexane. Each hexane layer was analyzed; however, extracts 3-6 were reduced in volume by 5-16 times before GC/FID analysis. All remaining extracts were combined to yield 66 ml of hexane extracts, which contained 40 mg/1 TCDD (2640 (ig) by GC/FID and 33 mg/1 by GC/MS. Column chromatography by method 1 gave 43 mg/1 of TCDD by GC/FID. Addition of the six extract analyses gave 2760 (tg TCDD.
HONS 221833
DESTROYING TCDD In HAZARDOUS waste :?3
Analysis of Photolysis Mixtures by Column Chromatography and HPLC Followed by GC/ECD
A sample of photolysis effluent from a photolysis run was spiked with TCDD to make a 620-ug/l solution. A I** 10-cm column was packed with 2 g of silica gel and 2 g of 44% HjSCVsilica gel, then 3.0 ml of the photolysis solution was placed on the column and eluted with 35 ml of hexane. The sample was concentrated to 3 ml. and a 67-pl sample was injected onto the HPLC. Fractions of the eluate were collected over the time interval consistent with retention times of a standard (5-8 min). The eluate was collected in a 25-ml volumetric flask which contained I ml of hexane. The solution was then washed with enough 1% w/w squeous sodium bicarbonate so that the hexane layer separated in the neck of the volumetric flask. The hexane was withdrawn with a disposable pipet, and the aqueous methanol solution was extracted with three successive I-ml portions of hexane. The combined hexane layers were reduced to 0.1 ml in a cone-bottom vial and analyzed by GC/ECD.
Scaleup Photolysis
A 4655-ml aliquot of extracts from the first three extraction scaleup experiments was placed into a 5-liter, 3-necked flask equipped with a quartz light-well through the center neck, a magnetic stirring bar and a reflux condenser connected to a trap filled with water. Technical-grade 1PA (85 ml) was added, the solution was stirred magnetically, and a 450W Hanovia mercury' lamp was inserted in the light-well and switched on. Samples were removed for dioxin and chloride ion analyses. Chloride ion was determined by extracting a 20-ml sample with 10 ml of water, The water and the water in the scrubber were analyzed by ion chromato graphy on a Dionex Ion Chromatograph using a 0.0024-M sodium carbonate/0.003-AS sodium bicarbonate eluent at 3 ml/ mtn through a 6- * 250-mm cation suppressor column followed by a 3- * 150-mm anion separator precolumn followed by a 3- * 500-cm anion separator column.
Miniplant Operation
Into a 4-liter, jacketed, glass resin kettle equipped with an agitator ("crow's foot") and condenser, w>as placed 1050 ml of 15% w/w sodium
MQNS 221834
174 DESTRUCTION OF DIOXINS
hydroxide solution and 1250 ml of technical-grade hexane. NEPACCO waste [322 g (,v233 ml)] was added, and the bottle was rinsed with an additional 250 ml of 15% sodium hydroxide. The mixture was heated to 42 C and stirred at 17,000 rpm for 20 min. After settling occurred, the top hexane layer was transferred by pump to a 3-liter, jacketed glass vessel. Successive extractions were performed with 610 and 305 ml of hexane, and the first five hexane extracts were combined in the photolysis reservoir. To this solution was added 56 ml of technical-grade IPA, and the yellow solution was pumped at 65-100 ml/min from the bottom outlet of the reservoir through a 250-ml photochemical reaction vessel into the top of the reservoir. The photochemical reactor was equipped with a 450W medium-pressure, Hanovia mercury-vapor lamp in a water-cooled immersion well and a reflux condenser. Sampling valves in the Teflon* lines allowed inlet and outlet samples to be taken at various time intervals. After 3.5 hr, the light was turned off. a condenser was placed on the photolysis reservoir, and the brown solution was distilled by heating with water/ethylene glycol. Distillation began at 59 C. and about 100 ml of distillate was collected when the vapor temperature reached 65C. The temperature gradually rose to 65C during the distillation.
To the caustic raffinate in the extractor was added with stirring 1294 g of 20.8% w/w sulfuric acid. The mixture separated into a brown aqueous layer (--2400 ml) and a black oil at the bottom.
RESULTS AND DISCUSSION
Composition of NEPACCO Waste
Characterization of wastes is the basis for any rational waste treatment process. Knowledge of the waste composition provided the key to successful treatment in this case. The tank contained the distillation residue from trichlorophenol purification. Presumably, trichlorophenol had been manufactured by treatment of te trichlorobenzene with sodium hydroxide in ethylene glycol at 150 and 200 C. Therefore, by-products from trichlorophenol production, phenols and TCDD were expected, and analytical procedures were based on these expectations. Solvent extrac tion of the waste gave a base-soluble fraction and a neutral organic fraction containing TCDD. GC/ MS analysis of these fractions revealed 42 different components. Figure I, the reconstructed GC/MS chromato gram of the base-soluble fraction, shows a variety of hydroxyl and
HONS 221835
DESTROYING TCDD IN HAZARDOUS ASTE 275
Flfur* 1. Reconstructed fat chromitojrxm for frsetion of wan* extracted into \5% methylene chloride/ benzene.
ethylene glycol derivatives of tetrachlorobenzene. The major portion of the base-soluble fraction, about 50% w/w, was trichlorophenol. The neutral fraction, shown in Figure 2, contained methylated benzylbenzenes (presumably impurities in tetrachlorobenzene), ethers of trichlorophenol and diethylene glycol, ethylene glycol and diethylene glycol derivatives of tetrachlorobenzene, tetrachlorobenze. and TCDD. These compounds are consistent with the manufacture of trichlorophenol by hydrolysis of tetr.chlcrobenzene.
TCDD was confirmed by GC/MS by matching GC retention times to within 0.1 min of a standard, and by the relative intensities at m/e 320 (74), 322 (100) and 324 (48). In addition, various purification techniques allowed GC/EC quantification. Purification methods, adapted from those described by Lamparski et a). [7], consisted of liquid chromatog* raphy through acid-treated silica gel, silica gel and alumina. Impurities were separated by elution with hexane, and dioxin was collected in 20% methylene chloride/hexane. The nominal TCDD concentration in the
HONS 221836
J'i DESTRl'CTION OF DIOXINS
SCAN SO
100 ISO 200 2SO 000 3SO 400
450 SOO
Ftfun 1. Rceoattnmed gas chromatogram for base-soluble fraction after extraction with IJft MeQj/PhH.
waste was 343 ng/g; however, collection of a representative waste sample from the tank was complicated by the dangerous nature of this waste and extreme difficulties in obtaining representative, homogeneous samples.
Process Selection
In addition to the analysis of the NEPACCO waste, three destruction processes (catalyzed wet oxidation, photochemical reduction and chemi cal treatment) were examined during the first phase of this project. The first two processes were tested experimentally and achieved a dioxin destruction of greater than 99% in preliminary lab experiments. Concep tually. catalyzed wet oxidation of the NEPACCO waste involved minimal handling, only one reaction vessel, and ltd to only inorganic, aqueous residues. However, this process used technology still underdevelopment and involved high pressure, a safety consideration. On the other hand, the
HONS
DESTROttNG TCDD IS HAZARDOUS WASTE
extraction-photolysis process destroyed only the dioxin, the most dan gerous component of the waste, left an organic residue and required several pieces of equipment and several stages of operation. On the positive side, the photolysis process used typical chemical engineering unit operations at ambient temperature and pressure under close process control. Because of the overriding factor of safety, the extractionphotolysis process was selected for further development.
Extraction-Photolysis
This TCDD destruction process is based on two important operations. First, dioxin must be separated from the majority of the waste compo nents by extraction with a suitable solvent. In addition to being selective in removing dioxin, the solvent extraction process also must remove >99.9% of the dioxin from the distillation sludge. Second, photolytic dissociation of the carbon-halogen bond must occur efficiently.
The ability to separate dioxin from other chlorinated waste compo nents is highly solvent-dependent. Figure 3 shows UV spectra of NEPACCO waste extracts in hexane, tetrachloroethylene and o-xylene. At dioxin concentrations of 1.2 mg/1, xylene and tetrachloroethylene extracts contain approximately 4 and 2.5 times more by-products, respectively, than hexane extracts. Hexane extraction of the NEPACCO waste removed the dioxin and about 2% w/ w of other chlorinated waste material. Greater than 99.9% extraction efficiency was achieved by successive batch extractions.
Photolytic dissociation of aromatic halides occurs under the influence of sunlight or UV light [8-10]. Sunlight or simulated sunlight degrades chlorodioxins in the presence of hydrogen donors [11, 12]. Pure TCDD in methanol decomposed 50% in 4-8 hours when exposed to simulated sunlight [15]. In addition, di- and trichlorodibenzodioxins degrade faster that TCDD [13], Chlorinated dibenzofurans. compounds closely related to dioxin, also are reduced by dechlorination and polymer formation [14], Thus, the literature data demonstrate that TCDD is dechlorinated by U V light. However, photolysis rates can be affected by light-absorbing impurities, radical inhibitors and, of course, fouling of the light-wells.
The rate of photolysis and the products formed are primary' concerns in any successful photolysis detoxication process. Figure 4 shows the rate of decomposition of dioxin in a hexane extract of NEPACCO waste. These experiments were carried out in photochemical reaction vessels with meaium-pressure mercury-vapor lamps immersed in water-cooled wells.
HONS 22183B
VS DESTRICTJON OF DIOXINS
280 300 320
Wavelength,
340
Fipift i. t'V spccuo of TCDD extract* of NEPACCO waste. (A) r.cxafw, (8) tewa* chlorocthyicnc'. (C) o-xtlcttc.
The photodecomposition rate is pseudo*first*order over a concentration range of five orders of magnitude, However, early work showed a marked rate decrease at about 99% TCDD reduction. This decrease in the rate of decomposition of dioxin was due to the fouling of the light*well by
HOMS 22183*
DESTROYING TCDD IN HAZARDOUS WASTE 27*
Flfurt 4. Rate or dioxin disappearance on UV irradiation.
HONS 221840
:so destruction of dioxins
oligomers of hexane. These polymeric photolysis by-products presumably arise after hydrogen abstraction from hexane. Further incidences of lightwell coating were prevented by adding other hydrogen donors, such as isopropyl alcohol, to the solution. The presence of isopropyl alcohol allowed the high degree of TCDD destruction shown in Figure 4 without affecting the rate of reaction. The rate of photodecomposition also is temperature-independent. These findings are consistent with rate-deter mining C-Cl bond breakage followed by reduction of the dioxin radical via hydrogen abstraction from the solvent.
Although photolytic conversion of dioxin to more highly toxic com pounds seemed unlikely, care was taken to examine the reaction products of the photolysis of the NEPACCO waste extracts. Extensive GC/MS analyses supported the postulated TCDD decomposition path shown in Figure 5 and were consistent with data of Botre [15] and Plimmer et al. [16], Exposure of TCDD and the other chlorinated organics in the hexane solution to UV light successively dechlorinates these compounds. Figure 6. the reconstructed gas chromatograms of photolysis solutions at different irradiation times, shows the disappearance of many chlorinated compounds that exist in hexane extracts of NEPACCO waste. For example, the disappearance rate of the diethylene glycol derivative of trichlorophenol is 0.54 times that of TCDD and follows similar first-order kinetics. When a photolysis sample was concentrated, a dark oil separated from hexane. This acetone-soluble oil contained ethoxylated phenol consistent with dechlorination reactions. No chlorinated compounds were detected at the end of exhaustive photolysis by GC/MS or direct-probe mass spectrometry.
No gas evolution occurred during photolysis. A sample of the vapor space above the photolysis solution was examined by GC/MS. Hexane and hexane isomers were major components, and 1PA and traces of 2chloropropane and acetone were present. The hydrogen chloride formed during photoreduction remained in solution. Photolysis of NEPACCO waste extracts yielded about 3.6 times the theoretical amount of hydrogen chloride based on TCDD. These data are consistent with dechlorination of dioxin and of the other organic components present in the hexane extracts.
Engineering Considerations
Conversion of laboratory data to full-scale plum design is always cifficult. In this case, the high toxicity of the dioxin-containing waste prevented normal scaleup methods im olving pilot-plant examination
HONS 221841
DESTR01 l>C TCOD [N HAZARDOUS WASTE :SJ
+ HCL
I 1
Figure S. Photoreduction product* of TCDO.
Consequently, great care was required in designing a laboratory mini plant that was safe, protected the worker and the environment and provided adequate scaleup data from 2 liters to 2000 gal, a factor of >3000. The full-scale extractor at Verona was intended to be an existing, 2000-gal glass-lined reactor. A laboratory version of this vessel was
HONS 22IBA2
:S1 DESTRUCTION OF DIOXINS SCAN
MOHS 221843
DESTROYING TCDD IN HAZARDOUS w \STE :SJ
designed carefully using a similarity approach to scale down to a 3-liter glass laboratory vessel. The proposed large-scale reaction vessel had an impeller-to-tank diameter ratio of 0.56, a tank height-io-diameter ratio of 1.32, an impeller tip speed of 1348 ft/min, and a Reynolds number of 5.3 - I06. The corresponding laboratory extraction vessel was designed to have an impeller-to-tank diameter ratio of 0.52, a tank height-to-diameter ratio of 1.03, an impeller tip speed of 1360 ft/min, and a Reynolds number of 0.4 10*. In addition, a retreating curve impeller was fabricated to maximize scaleup similarity. The mixing action in the laboratory extractor was visually similar to that of the 2000-gal reactor.
The following aspects were examined for photolysis scaleup: (1) optical density of TCDD solutions; (2) lamp characteristics, such as intensity, spectral distribution, spatial arrangement, commercial availability and safety features; and (3) interference by UV absorbers or fouling of the light-well. Hexane extracts of NEPACCO waste absorb UV light in the 200- to 320-nm region. Dioxin's absorption bands are at 235 and 306 nm.
Figure i. Reconstructed gas chromatograms for lOCr uopropvt alcohol hexane photo reduction alter (A) I', min. (B) 2! min: iC) .'00 min
HONS 221844
IU DESTRL'CTtON OF DIOXINS
Molar extinction coefficients are about 4.5 * 10* M*' -cm-1 and 6 * 10* M'1 -cm'1 at 235 [17] and 306 [11] nm. respectively. However, hexane
extracts of NEPACCO waste have apparent extinction coefficients in the 290- to 310-nm range that are 2-6 times higher than those calculated for pure dioxin. This increase in light absorption is presumably due to absorption by other tnchlorophenol derivatives extracted from the waste. Thus, 99% of the available UV light is absorbed within a very short distance from the light-well. This high solution absorptivity dictated the choice of the photolysis reactor design. Photochemical and safety con siderations led to the use of annular flow reactors with a batch recycle reactor system [18] in uhich the photolysis solution is pumped from a reservoir through a light reactor. The operational characteristics of a batch recycled reactor are described by:
C c`p',"l v'. o*i- e iv"r
(i)
where C, * inuial dioxin concentration i : reaction time f * pumping rale
Vt reservoir volume Vf reactor volume
k 5 reaction rate constant
Analysis of Equation I shows that pumping rate and reservoir and reactor volumes affect the reaction time, and that reaction time to achieve specific dioxin destruction is inversely proportional to reservoir volume. Practical considerations of available equipment fixed the reservoir to reactor volume, and the pumping rate was set at a relatively low 5 gal/ min per light reactor for safety reasons. Because of the high absorbtivity of the solution, good mixing in the light was crucial to allow transport of dioxin from the bulk solution to within 1-5 mm of the light-veil surface. Turbulent flow was also necessary to minimize deposition of photolysis products and fouling of the light-well. In the miniplant reactor. Reynolds numbers of about 100 were achievable, compared to the expected number of 14,500 in the full-scale system. With the excepuon of the inability to provide turbulent flow in the laboratory reactor, ail other parameters such as residence time and flowrates, were similar to those projected for the full-scale system.
In addition to physical and spatial scaleup considerations, the spectral distribution of suitable lights had to be examined. Since dioxin in hexane absorbs light below 520 nm, the light intensity in that region for the laboratory lamps had to be comparable to industrial lamps. Industrial
MONS 221845
DESTROYING TCDD IN HAZARDOUS WASTE IIS
uv lights and 450-W laboratory lamps have similar power outputs per unit area both in total power and in power available below 313 nm. The 100-W laboratory lamp, although convenient to use in preliminary laboratory experiments, has considerably lower power flux than ihe other lamps. Comparison of batch photolyses with the 450-W and 100-W lamps showed that the high-intensity lamp decomposed dioxin at a rate 12.9 times faster than the lower-intensity lamp. This observation is in accord with the fact that the 450-W lamp has a power output 11.6 times that of the 100-W lamp below 313 nm. Based on the data from the 450-W scaleup runs and the observation that all usable light is absorbed within 10 mm of the light-well, it was calculated that eight 10-kW lamps would be able to reduce a 6600-liter batch of hexane extract containing 40 mg/I of dioxin by 99.79% in 22 hours.
Operation of Destruction Proeess
At the conclusion of the laboratory and minjplant experiments, the third phase of the project--engineering, construction and operation-- began, Careful process engineering provided piping and instrument diagrams and equipment, piping and instrument specifications. This work incorporated careful planning for worker and environment protection by providing engineering controls, such as:
leak-proof pumps and piping connections; minimisation of pumps by pressure transfers; separate diked process areas; ; vent system with pressure reliefs; '.ame arrestors; and an emergency blowdown tank.
Careful attention to operating procedures and redundant instrumentation minimized the potential for mis operation and spills.
Detailed engineering design provided the final aid to plant construc tion. During the construction phase, the process and engineering were reviewed extensively by IT Enviroscience, Syntex and an EPA task force. A series of public meetings explained the process to town residents, and careful safety, industrial hygiene, environmental and emergency proce dures were put in place. A laboratory was equipped onsite for process control.
EPA approval was received on May 19, 1980. After a one-week startup period and addr. ona) troubleshooting. 160-gal batches of NEPACCO waste were run through the destruction process in five 2-week operating
MOMS 221846
:S DESTRUCTION OF DIOXINS
periods. Six extractions of the waste reduced the dioxin content from 343 to 0.2 ppm. Generally, photolysis reduced the dioxin concentration to less than 0.1 mg/1, with optimum photolysis times of about 20 hours. About 700 process samples, many at the ppb dioxin level, were analyzed to control the processing. Air sampling at the single process veni confirmed that no dioxin (less than 0.01 pg/m}) was emitted to the atmosphere during operation.
SUMMARY
The extraction-photolysis process for destroying TCDD in a hazardous waste was implemented in full-scale plant operation within 19 months of initial laboratory experiments. A 30Q0X scaleup of data from laboratory to full-scale plant was successful. Procedures developed for handling the very toxic dioxin prevented personnel exposure and environmental contamination. None of the extensive contingency procedures needed to be implemented. About 7 kg of dioxin were destroyed with 99.94% efficiency, and a significant hazard to the population of Verona, Missouri, and surrounding communities was removed.
ACKNOWLEDGMENTS
We thank G. Moll, R. Bagby and the Syntex operators for carrying out the operation successfully. C. Sawyer, L, Throop and K. Stormer, Syntex, provided continuity and technical assistance. L. Lamparski and T. Nest rick. Dow Chemical Co., and R. FIoranee. IT Enviroscience, provided guidance on dioxin analyses. V. Kalcevic and T. Dcnnke. IT Enviroscience. and G. Moll and \Y. Glasgow, Syntex. evaluated and implemented engineering concepts. The review function of J. Benv. M. Soudart, D. Crosby, A. Foss. A. Michaels. J. Olson. J. Smith and the EPA task force coordinated by K. Ritchie was helpful. During operation. D. Strother, T, Gcisler and M. Clark. IT Enviroscience, provided analytical and air sampling support.
REFERENCES
1 Les. D H K... and H L. F..!k. Edi. Environmental Health Perspectives National Institute of Health. Vo! 5 (Research Triangle Park, NC. !97?).
HONS 221847
DESTROYING TCDD IN HAZARDOUS WASTE 2*7
2. Blair, E. H-. Ed. ChJorodioxiru--Origin and Fait, Advances in Chemistry
Senes 120, E. H Blair. Ed. (Washington. DC: American Chemical Society,
1973).
3. Zack, M.. Jr.. J. A. Liddie. C. D. Carter. R. Kimbrough and W. W. Heath,
Jr. Public Health Service-CDC-Atlanu, EPA Report 75-17-2, (March 31,
1973).
4 Catienabi. F. A. Cava Hero and C. Galli. Eds. Dioxin: Toxicological and
Chemical Aspects (Jamaica. NY: Spectrum Publications, Inc.. 1978).
5, Kimbrough. R. D, CRC Critical Reviews in Toxicology (1974). p. 445.
6, Dot* Chemical Co., -Summary of Safe Handling of 2. 3, 7. $-Tet rich loro-
dibenzo*p*Dioxin (TCDD) in the Laboratory.- Agricultural Products Dept..
Midland, Ml (1977).
'
7, Lamps rski. L. L..T. J Nestrick and R. H Stehl./4nj/. Chem. 51:1453(1979).
5 Pinhey, J I., and R. D, J. Rigby. Tetrahedron Lett. (1969). p. 1267
9. Arnold. D R.. and P. C. Wong. J, Am. Chcm. Soe, 99:3361 (1977).
10. Bunce. N. J., and L. Ravanal. J. Am. Chem. Soc. 99:4151 (1977).
11. Crosby, D. G., and A. S. Wong, Science 195:1337 (1976).
12. Stehl. R. H . R. R. Papenfuss, R. A. Bredewig and R. W. Roberts.
Chlorodioxins--Origin and Fate, Advances in Chemistry Senes 120, E. H.
Blair, Ed. (Washington. DC: American Chemical Society, 1973), p. 119.
13. Crosby. D. G., A. S. Wong. J. R. Plimmcr and E. A. Soolson. Science
173:74* (1971).
14. Hutzinger, O., S. Safe. R. R. Wentzell and V. Zitko. In: Environmental
Health Perspectives Vat. 5. D. H. K. Lee and H. L. Falk. Eds. (Research
Triangle Park. NC: National Institute of Health, 1973), p. 267.
15. Botre, C,, Environ. Set. Technol 12:335 (1978).
16. Plimmcr. J. R,, V. 1, Klingebiel, D. G. Crosby and A. S. Wong. Chtoro*
dioxins-~-Origin and Fate. Advances in Chemistry Senes, 120, E. H. Blair.
Ed. (Washington. DC: American Chemical Society, 1973), p. 44.
17. Lampanki. L. Personal communication (1979).
18. Smith. G. M. Chemical Engineering Kinetics. 2nd ed. (New York: McGraw*
Hill Book Company. 1970). pp. 476-479.
HONS 221848
CHAPTER 18
ENVIRONMENTAL HEALTH AND SAFETY CONSIDERATIONS FOR A DIOXIN DETOXICATION PROCESS
Charles J. Sawyer Syntex (U.S.A.), Inc. Palo Alto, California 94304
Successful, environmentally safe destruction of nearly 4300 gallons of dioxin-laden sludge containing 343 ppm of 2,3,7,8-tetrachlorodibenzo-p* dioxin (TCDD) was a significant challenge. Syntex Agribusiness Inc. engaged the consultant services of IT Envirosciencc. Inc., to help develop a unique extraction-photolysis process to remove and subsequently destroy the dioxin from a complex, tar-like sludge residue. This residue was the resultant still bottoms from a hign-vacuum distillation of trichlorophenol (TCP). The material had been generated by a firm, the X"rth East Pharmaceutical and Chemical Company (NEPACCO), which leased a portion of a chemical plant that was later purchased by Syntex,
Syntex' primary goal for development of such a detoxication process was the safety of the public, its employees and the surrounding com munity, It was necessary' to break new technological ground lo develop a suitable, inherently safe dioxin detoxication process. Of the various processes considered, the extraction photolysis process conducted at moderate temperatures and ambient pressure accommodated most closely the safety criteria established.
An interdisciplinary team of Syntex scientists, technical experts in environmental health and safety, a Blue Ribbon Committee of academic and industry consultants, and several members frorr various go\ern-
:S9
HONS 221849
:*0 DESTRUCTION OF DIOXINS
mental agencies all worked 10 help plan, design and refine this process. More than 13 lb of dioxin (343 ppm) was safely detoxicated 10 < 0.2 ppm--a reduction greater than 99.9%. Because of the known toxicity of TCDD, strictly regimented environmental, health and safety guidelines were implemented for the conduct of the process operation to ensure that the environment, workers and surrounding area were adequately pro tected. Figure I depicts the range of activities that were covered.
ENVIRONMENTAL WASTE STREAMS
The extraction photolysis process for dioxin detoxication was designed to minimize the amount of contaminated waste streams generated. In terms of air emissions, the sole vent for the photolysis process was from a packed caustic scrubber unit capable of treating any evolved gases, nitrogen purge gas or displaced airspace volumes artsing from various process transfer operations. The vent was monitored continuously for organic vapor emissions by an alarm system designed to sound whenever levels greater than 25% of the lower explosion limit (LEL) for hexane, the key extracting solvent, were exceeded. The alarm never sounded during process operation. A portable organic vapor analyzer was available to detect system leaks, to determine solvent vapor levels associated with possible drips or spills, and to serve as a calibration check for the fixed, continuous alarm system. Additional periodic air sampling studies at the process vent were conducted by IT Enviroscicnce during strategic opera tions to further verify that there were no emissions of dioxin, A modifica tion of the U.S, Environmental Protection Agency (EPA) Method V for analyzing particulate emissions from stationary sources was used to analyze for dioxin using both filter and impinger techniques. Results of these studies confirmed emission levels of hexane well below predicted levels, and no detectable dioxin releases. Two Hxed air sampling stations were established at upwind and downwind process area perimeter loca tions to provide continuous dioxin monitoring. Additionally, five other plant site areas were sampled continuously 10 further verify that there had been no dioxin release. No detectable levels of dioxin (analytical limits of < 0.005 jig) were found at any of these fixed sampling points. Finally, as will be discussed further below, personal monitoring was conducted by filter cassettes and personal sampling pumps. Again, no dioxin was detected.
In terms of liquid or aqueous waste emissions. Table 1 summarizes typical waste analyses for the three process-generated waste streams. The neutralized oil and the still bo:;cms streams were kepi isolated in separate
MONS 221850
e n v ir o n m e n t a l h e a lt h a n d safett :i
tHVmONMfNTU WASTf STREAMS
AIM IMIS'.IOHS
_
AOUOirt tM*UK>IA
SOIn> MASKS joCNCRAnuH
PROCESS
vtm
f i/fo she
I Or AW*
SAMniNO
I'flOCFiS masks
WtlTfAuXED OSNUiFlMUMStOuI2fO(UMS
waic n
nAINWAUfl
invnmuOinArUitQnE
sCpOhNi inrx
MAlCJftAI'i
CciOotolfAHMMMaAtiircn
iPtm
AHALVllCAL WASTES
CKAllQE IfflUSC
5l*UWfWfcAN! TART MASKS
DECONTAMMA
InttefNuouAu
INDUSTRIAL HYGIENf
PERSONAL SAMPLINO s MONIIOflNQ
moTicitvc iOUPMKHI NCCOC
HUT0N4JCtNTCflAL
SAMPLINO PSA CS*AU9HtO
PTIDIOCOLt
noufiMC
OPtftAllO*
CMenoettct OFCnAIIQN
IICMTIt
IATC FT
mnccUdUcMalCMlHlI
pnaoocctiossuawnio
pnfiiAArur and post metsc physical HMHNAIPMS
MfOCU OGSf* VAMQNMNAiVM
BVN IfMMMA GOVERN UCWfAiAOCHCTJ UJC NMON coiMcncc REVtfWS
MPnOCCttSArCOUAROS
STANOAND OAtfUriNO PROCtOUntS
AOAtTTCAL J*f THOOS
PAf STARTUP BAf |1V D&CUBStQNB AND women education
IfPAL MWQUPMINT SHARK DOWN
CKMOlCfCIPCUHNCCYCBQNTINQK.NCT
DECONTAMMATIQN PROGtOUfK
Flwc 1. ImiroNdtriMil hrslth am! ssfcty CMShkT*iu>iu for dw*m tftioaicAiwn
HOMS 221851
DtSTRICTlON OF DIOXINS
Table I. Summary of Typical Environmental Vi attt Streams from Dioxin Detoxication Proem
Wane
NEPACCO waste* fed to process
Quantity pal tb 160 1841
Approximate Compotillon
Dioxin (ppm I
J4J
Other (%>
30% irtchlorophenol; 30% ethylene flycol derivatives
Neuirshred oil and siill bottoms residue after processing
173 I9J7
02 30% trichltifophenol. 50ft ethvicnc flycol derivatives, hexane traces
Neutralized water after processing
672 6411
<0.002
13% Na^O, I09t isopropyl alcohol and cihvlcnc flveoi derivatives: K486% water
steel storage tanks within the diked detoxication process area, pending final EPA approval for ultimate disposal. The neutralized water waste was stored in a concrete diked open-top tank located proximal to the detoxication process area wherein further natural degradation of any remaining low-level TCDD residues could occur by ultraviolet (U V) rays from sunlight. A separate 10.000-gal storage tank was available to contain rainwater that gathered within the detoxication process area. Scrubber discharges were either reused as part of the neutralization step during the extraction process, or neutralized and sent directly to the concrete diked tank. Aqueous wastes generated from the change house were approved by EPA for treatment in an onsite wastewater system. Solvents used in processing, when they became contaminated, were detoxicated in the extraction photolysis process, and the resultant material was rectcled into subsequent batches. At the end of processing, the final detoxicated solvent residuals were placed into a tank pending approval by EPA for ultimate disposal. Any solid wastes generated from spill absorption procedures, disposal of possibly contaminated work clothing, boots, gloves or goggles, or spent analytical operations, (e.g., disposable labora tory clothing, gloves and burettes) were kept isolated, and contained in marked 55-gal covered drums, pending EPA approval of final disposal procedures.
INDUSTRIAL HYGIENE
The focus for worker protection of the detoxication process operators included a comprehensive education concerning all the potential hazards
HOMS 221852
ENMRONMENTAL health and SAFETY :i3
tssociited with the process and an emphasis on the need for protection of any exposed skin surfaces at all times. The process was designed for 24hour operation, using a four-shift-per-day staffing of two process oper ators per shift inside the detoxication process, and a Syntex process supervisor stationed outside the secured area who oversaw the operation for technical suitability, sample gathering and analysis, and emergency response requirements. The emphasis for process operation was on stepby-step control by experienced, knowledgeable personnel throughout the detoxication process.
Access to the detoxication area could be gained only by authorized workers passing through a change house. All workers removed their street clothes on the clean side of the change house and put on fresh work clothes supplied by Syntex on the process side of the change house. The detoxication process operators were strictly trained to conduct certain industrial hygiene protocols during each shift of operation. One operator per shift had a personal sampling pump attached to his belt that pulled approximately three liter/min of air through a labeled filter eassette clipped onto his shirt collar to monitor his breathing zone for dioxin. Additionally, an organic vapor badge was worn by the same operator to substantiate that there was no overexposure to any solvents (primarily hexane). Each operator routed every other day wearing the pump, filter and organic vapor badge. The operator wearing the industrial hygiene equipment uas required to uke any necessary in-process samples. The operators were trained to calibrate the pump at the end of the shift, to log in and out pertinent sample information, and to record any unusual events that may have occurred during the shift. The filter samples, vapor badges and logged information were routinely transferred from the process side to the clean side of the change house for subsequent chemical analysis. None of the filters analyzed (analytical limits of < 0.005 jig) indicated any detecuble levels of dioxin, and the threshold limit values (TLV) of the process solvents (TLV of hexane ~ 100 ppm; TLV of isopropyl alcohol = 400 ppm) were not reached.
The process operators were required to wear supplied uniforms, chemical-resistant gloves, chemical safety goggles, safety shoes and hard hats. In addition, for any emergency operations (e.g., handling spills, process line disruption or fire), procedures required the operator to wear chemical wet suits, boots, uped sleeves and pant legs, face shields and suitable respiratory protection equipment. A self-contained breathing apparatus (SCBA) was designed to be the first-line respiratory protection for any emergencies, particularly under conditions where aerosolization of dioxin might be expected to occur. Four SCBA unitf each capable of .'0 mir. -tinimum air-supply were available from the process side of the change nouse, with an additional four air-suppiy tanks also kept readily
HONS 221853
:4 DESTRt CTIOv OF DIOXINS
available. Chemical cartridge respirators were issued and appropriately fit-tested for each person for use in emergencies that might result in exposures to organic solvent releases that would not be expected to contain TCDD, e.g., hexane or isopropyl alcohol. Fortunately, there were no situations necessitating the use of any of the emergency equipment.
The supplied uniforms were routinely laundered and dried by the process operators after each shift, using the washer and dryer located on the process side of the change house. Obviously, soiled white uniforms were not laundered, but were disposed of as solid wastes in marked and covered 55*gal drums located near the change house; any soiled gloves, safety goggles, hard hats, safety shoes, etc., were not reused or decon taminated. but were also disposed of in this manner. All operators were required to shower before going back to the clean side of the change house at the end of shift. Additional industrial hygiene restrictions forbade food, beverages or smoking in the detoxication process area, and dictated complete adherence to all change room procedures and routine inspection and maintenance of all respiratory protection equipment. The analytical laboratory personnel located in a segregated laboratory imme diately outside the detoxication process area were also required to follow stria industrial hygiene practices such as wearing disposable gloves and laboratory uniforms, restricting access to their work areas, and showering before leaving the isolated work area.
HEALTH
A comprehensive medical examination was conducted on all detoxica tion operation personnel before start-up, Table 11 summarizes the key parameters for medical examination and evaluation. Certain employee medical health anomalies, based on a physician's analysts and evaluation of *.ne parameters identified in Table 11 would preclude a person from working within the actual detoxication process and have him assigned outside this area. Each operator chosen to work within the detoxication area satisfactorily met all the health requirements. Following final
Table II. Employee Medical Hisi or)/Physical Examination Selected Evaluation Parameters
Huton1 of nervous disorder, drinking habits Evidence of preexisting chronic illnesses Evaluate skin/liver function Assets suitability 10 wear rcspiraiorv protective equipment
HONS 221654
environmental health and safety 29?
shutdown of the detoxication process, all the process operators and supervisors were given postprocess physical examinations as part of Syntex* ongoing state-of-the-art health surveillance program. A compre hensive evaluation by an interdisciplinary' team of Syntex physicians, epidemiologists, toxicologists, industrial hygienists and statisticians found no adverse health effects. This review included comparing indi vidual and grouped medical results to other nondioxin process chemical operators at the Syntex plant. During process operation, a local physician in the community who had conducted the prestartup physical examina tions was available to provide medical assistance on a routine or emergency basis as required for those people engaged in the detoxication process.
SAFETY
All steps designed to provide for safe operation were required 10 have been completed before startup of the detoxication process. A compre hensive review of the detoxication process by a Blue Ribbon Committee encompassing expertise in photochemistry, chemical engineering process analysis and reaction kinetics was completed before startup. Several governmental agencies, including EPA, the National Institute for Occu pational Safety and Health (NIOSH), the Occupational Safety and Health Administration (OSHA), the Missouri Department of Natural Resources and FDA participated with key Syntex managers in ongoing review meetings, detailed process flowsheet analysis and a final onsite walk-through of the detoxication facility before granting startup ap proval. Numerous safeguards were integral to the basic design of the process, including moderate-temperature and ambient-pressure process ing. totally enclosed process operation, diked and sumped process area, nitrogen transfer operations, isolated cooling water sources, small batch sues, outdoor process operation, corrosion-resistant tanks and piping, explosion-proof equipment, outdoor safety showers, and complete pro tective enclosure of the highly contaminated dioxin waste storage tank. Within the detoxication process, all reaction vessels were equipped with flame arrestors, and vented to a caustic scrubber system. All reaction vessels were connected to a bump tank via individual reactor pressurerelief devices. The entire process was color-coded for ease of reaction vessel and pipeline identification, and the photolysis light system was designed to shut down automatically in the event of an emergency.
Before startup, detailed standard operating procedures were drafted and compiled for all aspects of the batch detoxication process in a format
MOMS 221855
:W DtSTRICTlON OF DIOXINS
similar to that used in regular in-plant manufacturing processes. Analyt
ical methoas and procedures were developed and formalized for routine
in-process sample analysis of the process waste streams listed in Table 1,
and for monitoring extraction efficiency and extent of the photolysis
reaction. All of the analytical samples were taken through special liquid*
sampling valves, transferred to a locked sample box at the perimeter of
the detoxication process area, and subsequently transported to the
analytical laboratory just outside the process area in a specially designed,
absorbent-filled bucket earned by the outside process shift supervisor.
Detailed safety training programs were conducted to educate all
process workers on personal safety and industrial hygiene procedures, use
of routine and nonroutine protective and respiratory equipment, change
room procedures, firefighting techniques, hazardous spill control, med
ical monitoring programs, emergency shutdown and contingency pro*
cedures. and process sampling and transfer procedures. Each worker
received nearly 40 hours of classroom instruction and training on all
aspects of the detoxication process. Following the classroom training, the
entire detoxication process was tested using hexane and water solutions
containing no dioxin. The operators received onsite training in taking
analytical samples and operating the photolysis system, and conducted
several mock firefighting exercises before startup.
A comprehensive contingency plan was drafted and approved by EPA
in the event of a major spill, fire, explosion, tornado or offsite release of
materials. The plan included measures for immediate shutdown of the
process, containment, and subsequent action to alert the nearby popula
tion. A highly trained, commercially available chemical cleanup service
was on call to assist in any emergency during detoxication process
operation. Fortunately, no such emergencies arose during the process
operation. Nearly a dozen town meetings were held in the small com
munity ot Verona. Missouri, where the detoxication process was located,
to assure the local people of the safety of the operation, and that public
health and o*.ner considerations had been considered and more than
adequately met. Comprehensive decontamination procedure protocols
were developed for final cleanout of all proc ss piping and vessels, with
subsequent wipe test analyses to be conducted to verify that decontamina
tion was complete.
.
Additional safety precautions included continuous monitoring and
recording of prevailing wind conditions, and establishment of definitive
spill containment procedures using cob meal, a readily available absor
bent at the Syntex plant, to absorb any liquid discharges Oiher securiiy
measures required 24-hour guard duty at the entrance tc the p,ant site,
limited plant access for non-Syntex personnel.and a completely fenced-in
area surrounding the detoxication process.
MONS
EM IRONMENTAL HEALTH AND SAFETY 21T
Onsite representation of PA Region VI1 was present throughout the operation to monitor the day-to-day events of the detoxication process operation. Periodic sample splits were provided to EPA to assav and confirm the extent of detoxication. All results from laboratory samples analyzed by IT Enviroscience and Syntex personnel were made available to EPA. EPA established us own perimeter and area monitoring air sampling protocols as an independent verification of the safe operation of the detoxication process. EPA results confirmed that there had been no release of dioxin.
CONCLUSION
Operation of the dioxtn detoxication process in an environmentally safe manner resulted from a successful combination of industry, govern ment and academic expertise working toward a common goal. The primary objective of achieving and maintaining safety for the environ ment, operating personnel and the surrounding community was achieved. None of the extensive contingency plans for emergency protection of the public health and the environment needed to be implemented. Operating procedures, analytical methodologies, environmental, health and safety considerations, and emergency/contingency procedures are viewed as innovative, and should serve as models for the new and evolving field of hazardous waste management. Successful completion of this project demonstrates that technical expertise coupled with corporate responsi bility can interact to solve some of the difficult hazardou- wastes problems that face us today. The complex system of environmental and personal monitoring controls required for this detoxication process confirm, through the absence of any negative environmental impacts, the effectiveness of the precautions taken.
MONS 22185?
SECTION 4 BIOLOGICAL DETOXICATION; GENETIC
ENGINEERING, MICROBIAL AND ENZYMATIC TREATMENT
HONS 221850
CHAPTER 19
OPPORTUNITIES FOR DEVELOPMENT OF NEW DETOXICATION PROCESSES
THROUGH GENETIC ENGINEERING
James B. Johnston and Susan G. Robinson Institute for Environmental Studies University of Illinois Urbans, Illinois 61801
The U.S. Environmental Protection Agency <EPA) Advanced Envi ronmental Control Technology Research Center (AECTRQ at the University of Illinois has conducted a planning study to assess the opportunities and problems of developing new pollution control technol ogies using genetic engineering. The goal of this study was to document the scientific basis for the genetic engineering approach to poilution control, and to develop recommendations for a research policy to promote it. To achieve this goal, three working papers were assembled, each dealing with one of the following subjects:
1. description of problem potentially amenable to the genetic engineering approach:
2, description of the genetic engineering technologies available for creation of
new solutions to these problems: ? selective description of factors limiting natural btodcgradaiive processes, espc-
eiillv those that potentially may be manipulated by gcncuc engineering to create new pollution control technologies.
Each of these papers was reviewed by nationally recognized experts. In May 1<>S| these experts were brought to the University of Illinois to pamcipg'.e in a workshop lhat was organized around a discussion of the working papers. In addition, each paper was reviewed by a number of outside scientists and engineers.
301
MONS 221859
.02 BIOLOGICAL DETOVICATIOV
A detailed description of the conduct of this study, the content of the working papers and tht major conclusions from the workshop have been published [1]. The responses of the workshop participants and the outside " reviewers have been used to formulate policy recommendations that were transmitted to AECTRC in September 1981.
Information from the AECTRC study relevant to biological detoxica tion of pollutants is assembled here, along with comments on the genetic engineering approach and possible barriers to the development of such new treatments.
RELATION OF DETOXICATION TO WASTE TREATMENT
To view detoxication from the perspective of the AECTRC genetic engineering planning study, it is necessary to recall that the fundamental axiom of toxicology states that all compounds are toxic if given to a test organism at a sufficiently high dose [2]. Thus, chemical compounds may differ in the concentration required to exert a deleterious influence on an organism, but all compounds potentially are toxic. By definition, com pounds that exert deleterious influences on living organisms are said to be toxic to those organisms. Compounds are only toxic, therefore, with reference to some organism. From the anthropocentric, environmental perspective of this chapter, discussion will be limited to environmental pollutants that potentially may affect human health.
Detoxication is the transformation of a toxic substance into a less toxic product. Studies that determine the quantitative toxicity of a group of closely related compounds often find that one or a few substituent groups on the molecule impart the greatest fraction of the toxicity. For instance, nitroso- or ehloro- substituents on a molecule frequently increase mam malian toxicity. Therefore one important mechanism of detoxication is the removal of the most toxic substituents. Primary biodegradation, a simple, biologically catalyzed change in a molecule that alters its chemical identity, can accomplish detoxication: similarly, mineralization of the compound (ultimate biodegradation) can also accomplish detoxication. Unfortunately, primary biodegradation can sometimes increase the toxic ity of a compound by convening a less toxic substituent to a more toxic form. Reduction of aromatic nttro- groups to hydroxvlamine and sequen tial methylation of mercury (Hg*-) by anaerobic microbes in sediments are examples.
In addition to biodegradation, pollution treatment often reduces the toxic manifestations of a compound by diluting the toxicant or by physical sequestration of the toxicant into a phase not in contact with the
HONS 221860
NEW PROCESSES THROUGH GENETIC ENGINEERING 3*3
organism. Neither of these approaches to treatment alter the chemical composition or the inherent toxicity of the compound.
GENETIC ENGINEERING AND DETOXICATION
Improvements in the biodegradation of toxic pollutants through genetic engineering will ultimately rest on certain kinds of genetic manipulations that have only recently become possible. These manipu lations include (1) rearrangement of genes from almost any source in microorganisms of almost any species; (2) amplification of the number of gene copies in an organism and concomitant amplification of the level of protein products made from those genes; (3) circumvention or alteration of control on the expression of particular genes; and (4) site-specific (gene-specific) mutagenesis to delete genes from an organism or to alter the characteristics of the gene product (enzyme), including changes in substrate specificity and kinetic constants.
The ways in which such manipulations might be used to develop organisms with enhanced or novel biodegradative capabilities can best be illustrated by considering a specific example. One broad class of com pounds with a great potential for toxicity and widespread exposure to the human population are the manmade halogen^ontaining compounds. In general, these compounds are biodegraded in the environment much less readily than their nonhalogenated analogs. A brief examination of the genetics and enzymology of dehalogenation will illustrate many of the ways by which genetic manipulation might enhance the degradation of some of these compounds.
The enzyme-catalyzed destruction of the carbon-halogen bond was reviewed by Goldman [3], and there have been few important additions to this literature since that time. Briefly, Goldman identified two groups of dehalogenases, one whose primary function appeared to be dehalogena tion and a second, which catalyzed dehalogenation but whose normal cellular function did not involve halogenated substrates. The first group consisted primarily of enzymes in aerobes catalyzing the hydrolytic displacement of halide from aliphatic acids (hydrohalidases) and enzymes in anaerobes catalyzing removal of HCl from DDT (dehydrohalidases). Hydrohalidases that are specified by plasmid-bome genes have been reported in Moraxella sp. [4,3]. Several kinds of hydrohalidases have been described [3]; each typically attacks a small group of closely related substrates.
The second group of enzymes were termed adventitious dehalogenases by Goldman, since the dehalogenation seemed to be an extrinsic and
MOWS 221861
304 BIOLOGICAL DETOXICATION
fortuitous function. The primary function of these enzymes is not dehalogenation. They are, however, able to remove the halogen as a result of the usual reaction that they catalyze. Adventitious dehalogenases often produce a chemically unstable form of the halogen, such as halohydrin, which then decomposes spontaneously 10 release halide. An example is fumarase, which can accept lluorofumarate and produce 2-fluoromalate. This compound then rearranges to form oxaloacetaie and fluoride [6], The mechanism of halogen removal by other adventitious dehalogenases is less well defined. Oxygenases are frequently able to displace halogen from halogenated analogs of their normal substrates. Examples include the dioxygenase that removes fluoride from orrho-fluorobenzoate [7J to produce catechol and the lactonizing enzyme that displaces chlorine from 4-chloro-ciJ.dlf-muconic acid to yield cis,cif-muconolactone during the catabolism of 2,4-dichlorophenoxyacetic acid [8,9]. The halogen that is removed occurs at the particular position on the molecule attacked by the oxygenase. Goldman has given examples of several other adventitious dehalogenation enzymes, and has suggested that close scrutiny of other isolated enzymes for the ability to accept and dehalogenate analogs of their normal substrates may reveal many more examples.
The existence of adventitious dehalogenases in an organism is not in itself sufficient for efficient detoxication of a compound. A halogenated environmental pollutant muit be taken up by an organism and the compound must reach the dehalogenase in a form able to be metabolized by it. Thus, all halogenated intermediate molecules formed from a halogenated compound must be tolerated and transformed by all of the enzymes on a pathway leading to the dehalogenase step. Halogenated intermediates that are not accepted as substrates by these enzymes will prevent the compound from arriving at the dehalogenase in a form that can be metabolized. Also, if an enzyme preceding the dehalogenase can bind a halogenated intermediate but not metabolize it, the halogenated intermediate may act as an inhibitor of that enzyme, reducing the metabolism of its normal substrate and potentially poisoning the cell. For these reasons, the existence of an adventitious dehalogenase in an organism is merely a prerequisite for effective destruction of a haloge nated pollutant.
To modify an organism for efficient dehalogenation, the molecular biologist can, in principle, select mutant forms of enzymes tolerant of halogen-substituted substrates. Studies extending the substrate specificity of an amidase suggest that mutation and selection can easily modify that portion of an enzyme's structure concerned with substrate recognition and binding, without affecting the structure of the active site [10]. Thus, halogen substitution at some distance from that pan of a substrate bound
MONS 221862
NEW PROCESSES THROUGH GENETIC ENGINEERING 3H
to the active site of an enzyme should be more easily tolerated. Since most mutant enzymes acquiring a dehalogenation activity have altered active sites, they are more difficult to select than enzymes simply tolerant of hatogenated substrates. Mutations affecting the active site of an enzyme are less likely to occur and harder to isolate. In these mutants, a small fraction of the protein determining the critical structure of the active site is involved. It is well known that even minor changes in bond angles and distances in an active site often strongly reduce catalytic activity.
Recent advances in mutagenesis and selection facilitate isolation of halogen-tolerant mutants. Site-specific mutagenesis permits alteration of only specific regions of DNA, improving the yield of mutants in a desired gene. Timmis described various ways of performing in vitro site-specific mutagenesis [II] and Kleckner et al. [12] described the uses of transposons for site-specific mutagenesis. A continuous culture has been adapted specifically for selection of mutants catalyzing dehalogenation by Senior and co-workers [13,14]. They grew a carbon-limited culture of Pseudomonas puiida on propionate in the presence of a fivefold excess of 2,2-dichloropropionate (dalapon). The propionate, called the carrying substrate, sustained the culture. Any mutants able to dehalogenate dalapon and use it as a carbon source would have a greater carbon pool available to it, should grow faster and displace the parental type from the chemostat. Adaptations of this technique in concert with site-specific mutagenesis hold great promise for the adaptation of existing catabolic pathways to recalcitrant analogs.
An elegant example of extension of a pathway by introduction of the genes for enzymes degrading halogenaied substrates was described by Reineke and Knackmuss [15]. They observed that a Pseudomonas species carrying the TOL plasmid (a self-replicating unit of DNA, specifying the enzymes for the degradation of xylenes and toluic acids via catechol [16]) was able to metabolize both 3- and 4-chlorobenzoic acid to the corres ponding chlorocaiechols. The enzymes apparently accept chlorobenzoates as analogs of the corresponding toluic acids. The plasmid-specified enzymes could not accept chlorinated catechols, however, and the further metabolism of the chlorobenzoates was blocked at this step. Reineke and Knackmuss [IS] were also aware of a Pseudomonas strain B13 that was able to mineralize 4-chlorocatechol, but which was unable to oxidize chlorobenzoic acids to chlorocatechol. By introducing the TOL plasmid into strain B13 and selecting for growth at the expense of 3- or 4chlorobenzoic acids, they obtained a derivative strain that could mineral ize either of these benzoic acids. This strain apparently possessed mutations in regulatory functions that allowed expression of plasmidencoded functions through catechol and chromosomal functions there*
HONS 221863
; BIOLOGICAL DETOXICATION
after. It was then used in further mutation and selection studies to extend the nnge of substmes subject to dehalogenation. Bull's strategy was used; a mutagenized culture was grown in a chemostai in the presence of 3-chlorobenzoate, a carrying substnte and a variety of other chlorinated benzoates not normally used by the strain. The nonutilized substrates were chosen so that single dehalogenaiiona would allow the organisms to metabolize them. In this way, mutants were isolated that could mineralize 3,5-dichlorobenzoic acid. Neither the TOL-bearing strains or strain B13 had previously attacked this compound. It must be recognized, however, that most of these alterations required a detailed knowledge of the molecular genetics of the catabolic pathway being manipulated. This implies a substantial investment in basic research before similar manipu* lations could be undertaken in uncharacterized species.
Mutants might be improved further by increasing production of the enzyme of interest. This improvement can be accomplished by selecting constitutive mutants (mutations in regulatory genes that lead to continual synthesis of specific proteins), recombining the genes for the enzyme with strong promotors, as described by Timmis [12], and amplifying the number of copies of the relevant genes in an organism by using multicopy plasmids or gene duplications [II], All of these manipulations could result in an increased carbon flux through the cell, allowing a simple selection on the basis of enhanced growth rate.
Once a particular pathway has been developed, existence of trans missible plasmids suggests a strategy to introduce it to indigenous organisms. Just as acquisition of the TOL plasmid extended the range of substrates utilized by strain BI3, acquisition of a plasmid with a suite of genes specifying an entire catabolic pathway for a particular xenobiotic might quickly acclimate microflora without requiring colonization by an introduced organism. While the facility of plasmid transfer in nature is not well documented, plasmid spread under laboratory conditions can be explosive.
ECOLOGICAL CONSIDERATIONS
Barriers to the development of pollution control technologies based on genetie engineering are more likely to be found in the process of bringing an engineered organism to a polluted environment and having it function successfully in that environment than in the process of developing the organism itself. The genetic engineering industry was bom from basic research in DNA enzymology and plasmid biology that grew into a set of tools for manipulating DNA. This industry is now integrating fermenta
HONS 22X86*
NEW PROCESSES THROUCH GENETIC ENGINEERING JOT
tion technology and molecular biology for the production of previously unavailable biochemicals. The development of pollution control techno logies would require a similar coordination of microbial ecology with molecular biology. In contrast to fermentation technology, however, microbial ecology at the moment is a science leu able to make pre dictions. In particular, the microbial ecologist cannot yet evaluate the possibility of success of efforts to establish engineered microbes in contaminated environments. This situation is a consequence of the complexity of the ecology of microbes and the small amount of attention historically paid to this subject.
In contrast to the development of the genetic engineering industry producing novel biochemicals, pollution treatment technologies based on engineering organisms are stalled temporarily by the uncertainties atten dant on gene transmission from introduced, engineered organisms or the competiiiveneu of such microbes in the environment and their potential for establishment. Few direct attempts have been made to evaluate gene transmission from altered organisms to indigenous organisms or to evaluate their potential for establishment in nature. One such study was undertaken to evaluate the probability of escape of genetically debilitated organisms used for research or commercial production of biochemicals [17,18], This work demonstrated the fragility of organisms Tike A"1776 when exposed to the environmental conditions typically found in tem perate climates. It also attempted to, evaluate the potential of such organisms to colonize the mammalian gut. Since Xfflb is debilitated by design, it is understandable that this work failed to demonstrate establish ment. This does not necessarily reflect the potential of organisms normally resident in aquatic and terrestrial environments, especially if these organisms have had only minimal genetic alteration. Lack of experimental information, however, does not allow a conclusion to be drawn.
A number of companies exist that sell microorganisms claimed to improve or enhance the biodegradation of various components of waste streams in waste treatment facilities or of pollutants in situ in the environment. This apparent source of information on the effectiveness of introduced organisms has been found to be of little value. It is in the interest of these companies to know whether organisms introduced into a resident microflora can colonize or transmit relevant genes to indigenous microbes. Data on the use of one of these commercial microbes has shown ihai establishment and effective biodegradation can occur when these organisms are introduced into a lab-bench aeration basin lacking a resident microbial population [19]. We are unaware, however, of any information clearly showing the effectiteness of these organisms intro
HONS 221865
301 BIOLOGICAL DETOXICATION
duced into normally operating full-icale aeration basins or natural environments having an active resident microflora. None of the infor mation called to our attention and purporting to demonstrate the effectiveness of seeding with these products meets normal criteria for a scientific experiment, especially with regard to the controls. Superficially, most of these data appear to show small improvements in treatment when a facility is seeded with these organisms. This is either not supported by analysis of the data, or the experimental design is inadequate to conclude that the effect was due to the added microorganism rather than other, uncontrolled factors. From information that we examined it was im possible to determine whether these introduced microorganisms can establish themselves and significantly enhance treatment in a normally operating facility or a polluted environment.
Exploratory studies should be undertaken by interested scientists to evaluate the colonization potential of introduced microorganisms in habitats such as aeration basins, and an evaluation of gene transmission to resident microbes following seeding with an engineered strain. Such experiments must be undertaken with adequate controls and carried out in a manner that recognizes and measures changes in the performance of the treatment facility dependent only on the introduction of the engi neered strain. Concomitant with this direct experimental approach, basic research is needed to develop understanding of the factors affecting the success of introduced microbes. Historically, the establishment of intro duced microorganisms has been studied in the context of infection and disease, with the single exception of the inoculation of soil with Jthfeobium. Of course, in this case the establishment of the introduced organism depends on the presence of a special habitat, the legume root.
Many kinds of physical and biological factors have been recognized as important for the success of an introduced microbe. Obvious factors include the availability of adequate nutrients, acceptable pH, oxygen tension, and presence or absence of light. Manipulation of these factors should not be overlooked as a means to enhance degradation of a pollutant. For example, degradation of Arctic oil spills apparently can be accelerated by relieving phosphorus and nitrogen starvation of microbes associated with them [20]. Additional factors of special relevance to waste treatment and biodegradation include concentration of the pollutant, occurrence of the pollutant in mixtures of more easily metabolized and/or toxic compounds, availability of water, and sorption of com pounds and microorganisms to surfaces.
The relationship of the concentration of a compound in bulk solution to us rate of biotransformation has been neglected frequently by the molecular biologist interested in enhancing biodegradation through
MONS 221866
NEW PROCESSES THROUGH GENETIC ENGINEERING Jw
genetic manipulation. Most microorganisms used for studies of biode gradation are selected for their ability to degrade the compound of interest and to do so in a manner that is convenient to study. They are obtained from enrichment cultures with the target compound as sole or principal source of carbon and energy at a concentration that can support rapid growth. Because they can grow rapidly when exposed to abundant substrates, these organisms are sometimes called "eutrophs" (from the Greek eutrophos, meaning well nourished). The complementary group of slow growing organisms capable of surviving on very low substrate fluxes (called oligotrophs from the Greek oiigo, meaning few or scant, plus trophos meaning fed) are not often isolated by this method.
Most of the organisms used in basic molecular biology, e.g.. typical Enierobacteriaeeat and Pseudomonedactae, are eutrophs unable to effectively catabolize single substrates at pa rts-per-billion concentrations, even if they may grow on the same substrate at parts-per-million concentrations. Many toxic or persistent pollutants of concern in the environment are present at parts-per*billion concentrations and therefore are more likely to be attacked by oligotrophs, if at all. There is very little fundamental information regarding the biochemical adaptations of oiigo* trophs that permit them to succeed under low nutrient conditions, but a basic outline of their characteristics has been published [21]. At least cursory consideration should be given to the concentration of a target pollutant in a contaminated environment when planning the genetic alteration of an organism to enhance its attack on the pollutant.
Another basic microbial adaption that should receive at least passing attention is the tolerance of the engineered microbe for environmental stresses. Stresses of particular importance in waste streams and polluted environments are reduced water activity and the presence of toxicants. Any particular microbial species can tolerate only a limited range of water activity. These limitations are well known and widely exploited for the preservation of food (e.g., pickling brines and sugar syrups). In waste streams and polluted environments, water activity may be reduced by salts or partially water-soluble solvents (solvents can be biocidal both from a reduction in water activity and by direct solvent action on microbial membranes). Bacteria use at least two genetically controlled strategies to function in reduced water activity environments [22]. The first is the synthesis of enzymes that function normally only at elevated ionic strengths. The second is the synthesis of internal solutes, especially proline and glutamate, that raise the internal osmolarity so as to balance the external environment, but without interfering with normal metabolic functions. Because the latter adaptation probably involves fewer genes, it appears to be more amenable to alteration by genetic manipulation.
HONS 22X867
31# BIOLOGICAL DETOXICATION
Fungi, which are generally better able to tolerate reduced water activity tnan are bacteria, may employ additional mechanisms.
Toxic substances in waste streams and polluted environments present complex and little studied problems affecting biological treatment of many waste and polluted environments. To approach this problem requires an initial assessment of the nature and abundance of the toxicants. Next, their availability to the microbe must be considered, since many toxicants may be sorbed, partitioned into nonaqueous phases or complcxed. Degradation of a component of a polluted environment could release ;he toxicant, a potentially suicidal action from the microbe's perspective. Since the abundance, variety and disposition of microbioctdes in polluted environments arc often unique to each site, this factor is usually ignored until a normally efficacious microbial treatment fails. From the perspective of a molecular biologist, it would be useful to note that microbes differ substantially in their tolerance to general chemical biocides such as phenol, hypochlorite and various solvents, but the genetic basis for tolerance has not been explored systematically, It is also useful to note that bacteria employ a number of strategies to avoid heavy metal toxicity, some of them specified by genes on plasmid DNA and potentially transmissible to related strains. An example of the variety of possible actions are the Hg,+-reducing and Hg^-methylating activities of bacteria. The success of these activities in the environment is suggested by the ease of isolation of mercury resistance functions from bacteria in mercury-contaminated sediments [23],
Other considerations for the molecular biologist designing new pollu tion treatments include the occurrence of pollutants in mixtures of other potential nutrients and the physical interactions of compounds. Mixtures may be advantageous to the genetically altered microbe if they contain a compound that can be used as a growth substrate to support the cometabolism of another, presumably recalcitrant, component of the mixture. Creation or extension of cometabolie capacity in bacteria through mutation and selection, especially site-specific mutation, is an endeavor of enormous practical importance. The same principle of enzyme and pathway alteration discussed in connection with extending adventitious dehalogenation reactions can be applied to the extension of cometabolie transformations. The genes for enzymes catalyzing the transformation of a utilizable compound may be mutated, and variant strains may be obtained that retain the enzyme's active sites but have acquired the ability to act on closely related substrates (cosubstrates) not metabolized by the parental strain. Since these mutant enzymes are likely to be selected one at a time and the organism will not derive benefit from
HONS 221868
NEW PROCESSES THROUGH GENETIC ENGINEERING 311
the transformation until the entire pathway has been altered, a growth substrate is necessary for the organism.
The principal difficulties created by occurrence of compounds in mixtures involve inhibitory interactions of components of the mixture with the microbe. Beyond components that are biocidal or that alter the nature of the physical environment, compounds may be competitive or dead-end inhibitors of essential enzyme reactions, thereby reducing metabolic rates. Compounds also may act as regulators of metabolism tcoinducers and corepressors) that alter a metabolic pattern in an unfavorable way. Examples of such action from studies of pure cultures of eutrophic bacteria (and hence of unknown relevance to mtxcd flora and complex mixtures of compounds) include catabolite repression by glucose or succinate in E. eoli and P. putida, respectively.
Both problems and opportunities are created for microbes by their interaction with interfaces, and by interfacial influences on xenobiotic compounds. Particularly important are the solid-liquid interfaces found in sludge, on the surfaces in trickling filters and routing biological disc reactors, and in soils and sediments. Bums has discussed influences associated with interfaces affecting the microbial breakdown of pesticides [24], These include potential increases and decreases in the rate of transformation of compounds sorbed to a surface, enhanced tolerance of sorbed microbial populations to transient changes in the aqueous envi ronment (pH, temperature and shock loadings), sequestration of com pounds and alteration in genetic exchange among microbes.
Adhesion of microbes to solid surfaces is an extremely common occurrence. Simple models suggest that surfaces wetted with a water film of thickness less than the minimum dimensions of a particle will develop capillary forces sufficient to bind the particle to the surface [25]. These conditions typically are found in soil and bind bacteria to surfaces. Such forces may severely restrict the movement of an introduced, engineered microbe into the soil column where iu urget compound resides. Adhe sion of microbes to surfaces in aquatic environments and in treatment facilities usually involves a modification of the surface by deposition of a glycoprotein, conditioning and modifying the properties of the surface.
Effects specific to the structure of the glycoprotein and microbe, and general influences dependent on ionic strength, glycoprotein concentra tion and coverage of the surface all affect adhesion (for an excellent, detailed discussion see Berkeley et al. [26]). The importance of microbial adhesion to the success and spread of an introduced species is not known, nor has the opportunity to manipulate adhesion phenomena by genetic alterations of microbial glycoproteins been explored.
HONS 221869
312 biological detoxication
CONCLUSIONS
From the preceding sections it is evident that development of improved treatments for toxic wastes through genetic manipulations of micro* organisms will require contributions from a number of disciplines and the successful integration of this knowledge in a goal-oriented fashion. The breadth of information needed to intelligently develop new treatments is itself an impediment, since it is difficult for specialists to communicate across such a broad range of knowledge. Newsletters, problem-focused symposia and short courses might be used to coordinate the activities of scientists in relevant disciplines.
The most pressing area of basic research is the need to evaluate the potential of engineered organisms to colonize polluted habitats or to spread new genetic information to indigenous microbes. Before genetic intervention can be used to enhance colonization or plasmid spread, it seems likely that further basic research will be needed to characterize microecosystems, especially those present in treatment facilities. Because the conditions in treatment facilities are better controlled than in open environments, it is plausible to expect that the first applications of genetic manipulation will come in this setting. Equally, the evaluation of colonization or plasmid spread should be easier in the microflora associated with a treatment facility than in the open environment. On the practical side, the costs of defining environmental factors (such at the presence and availability of microbial toxicants) can be justified more easily when viewed as a step toward improvement of the performance of a waste treatment facility.
Whether new treatment technologies can be developed expeditiously will depend on the outcome of these studies. The promise of incisive gene manipulation urges timely exploration of this approach.
REFERENCES
1, Johnston, J. B,, and S. G. Robinson. "The Development of New Pollution Control Technologies Using Genetic Engineering Met hod*-An Assessment of Problems and Opponunities," in Proceedings of the Baittllt international Conference on Centric Engineering (New York: Raven Press, in press), p. 24.
2. Paracelsus (Theophrastus ex Hohenheim eremite). Ron tier Besueht. Dillingen, 1567.
5. Goldman, P. "Enzymology of Carbon-Halogen Bonds," in Degradation of Srnthetie Organic Molecules in the Biosphere, Proceedings of a Conference (Washington, DC: National Academy of Sciences, 1972), pp. 147-165.
HONS 221870
NEW PROCESSES THROUGH GENETIC ENGINEERING 313
4. Kawasaki, H,, N. Tone and K. Tonomura. "Plasmid-Determined Dehalogenation of Haloaceuies in Moraxella Species,' Afric. Biol. Chtm. 43(0:29-34 (1981).
5. Kawasaki, H., N. Tone and K. Tonomura. "Purification and Properties of Haloaeetatc Hilidohydrolase Specified by Plasmid from Moraxella sp. Strain B," Agnc. Biol. Chtm. 45(l);3J-42 (1981).
6. Clarke, D. D.. W. J. Nichlaui and J. Palumbo. "FIuorofumarate-- A Substrate for Fumarate Hydraiase." Arch. Biochem. Biophys. 123:203-206 (1968).
7. Goldman, P. "The Enzymatic Geavage of the Carbon-Fluorine Bond in Fluoroacctate,* / Biol. Chem. 280,3434-3438 (1965).
8. Bollag, J. M., C. W. Helling and M. Alexander. "Enzymatic Hydroxylation of Chlorinated Phenols," / Agnc. Food Chtm. 16:826-828 (1968).
9. Tiedje. J. M., J. M. Duxbury. M. Alexander and J. E. Dawson. "Pathway of Degradation of Chtorocaiechols by Arthrobacitr sp.,"/ Agric. Food Chtm. 17:1021-1026 (1969).
10. Garke, P. H. "The Evolution of Enzymes for the Utilization of Novel Substrates," in Evolution in the Microbial World. Society for Genera! Microbiology Symposium 24, M. J. Cartile and J. J. Skehel, Eds. (Cambridge: Cambridge University Press, 1974), pp, 183-218.
11. Timmis, K. H. "Gens Manipulation in Vitro," in Genetics as a Tool in Microbiology, Society for General Microbiology Symposium 31, S. W. Glover and D. A. Hopwood, Eds. (Cambridge: Cambridge University Press, 1981), pp, 30-109.
12. Klcckner, N.. J. Roth and D. Botstein. "Genetic Engineering in Vivo Using Translocatablc Drug-Resistance Elements: New Methods in Baeterial Genetics," / Molrc. Biol. 116:123-139 (1977).
13. Senior, E., A. T. Bull and J. H. Slater. "Enzyme Evolution in a Microbial Community Growing on the Herbicide Dalapon," Nature 263:476-479 (1976).
14. Slater, J. H., D. Lovatt, A. J. Wcightman, E. Senior and A. T. Bull, "The Growth of Pseudomonas putide on Chlorinated Aliphatic Acids and its DehaJogenase Activity," / Gen. Mlcrohtol. 114:125-136 (1979).
15. Reinekc, W.,and H.-J, Knackmuit. "Construction of Haloaromatic-Utilizing Bactena," Nature 277:385-386 (1979).
16. Worsey, M. J.. and P. A. Williams. "Metabolism of Toluene and Xylenes by Pseudomonasputida (arvilJa) tnt-2: Evidence for a New Function of the TOL Plasmid." / Bacterial 124:13 (1975).
17. Sagik, B. P., and C A. Sorter. "The Survival of Hosl-Vecior Systems in Domestic Sewage Treatment Plants," Fee. ONA Tech. Bull. 2(2):55-6l (1979).
18. Levy, S. B., and B. Marshall. "Survival of coii Host-Vector Systems in the Human Intestinal Tract," Ret. DNA Tech. Bull. 2(2):77-80 (1979).
19. HoUaday, D. W., C W. Handler, C. D. Scott and D. D. Chiicoie. "Biodegradation of Phenolic Waste Liquors in Stirred-Tank. Packed-Bed and Fluidized-Bed Bioreactors,' / Water Foil. Control Fed. 50:2573-2389 (1978).
20. Atlas. R. M. "Fate and Effects of Oil Pollutants in Extremely Cold Marine Environments." Office of Naval Research Report Contract No. N00014-76-C-
0400, p. 67.
21. Hirsch, P,, M. Bernhard, S. S. Cohen. J C. Ensign. H W Jannash. A. L. Koch. K. C. Marshall. A. Matin, J. S. Poindexter. S. C. Rittenberg. D. C.
HONS 231871
.'14 biological detoxication
Smith and H. Veldkamp. "Life Under Conditions of Low Nutrient Concentration!: Croup Report," in Strategies of Microbial Life in Extreme Environments. Dohitm Konfertmtn, M. Shiio, Ed. (Weinheim.FRC: Verlag Chemie, 1979). pp. 357-372, 22. Reid, O. S. `Water Activity as the Criterion of Water Availability," in Contemporary Microbial Ecology, D. C. Ellwood, J. N. Hedger, M. J. Latham, J. M. Lynch and J. H. Slater, Eds. (New York: Academic Press, lnc,, 1980), pp. ) 5-27. 23. Walker. J. D., and R. R. Colwell. 'Mercury-Resistant Bacteria and Petroleum Degradation," Appi Microbiol. 27{ I ):285-2B7 (1974), 24. Bums. R- G, "Interaction of Microorganisms, Their Substrates, and Their Products with Soil Surfaces," in Adhesion of Microorganisms to Surfaces, D. C. Ellwood, J. MeIJing and P. Rutter, Eds. (New York: Academic Press, Inc., 1974), pp. 109-138. 25. Tadros, T. F. 'Particle-Surface Adhesion," in Microbial Adhesion to Surfaces, R. C. W. Berkeley, J. M. Lynch, J. Melting, P. R. Rutter and B. Vincent, Eds. (Chichester, U.K.: Ellis Horwood, Ltd., 1980), pp. 93-116. 26. Berkeley, R. C W,, J. M. Lynch. J. Melting, P. R. Rutter and B. Vincent, Eds. Microbial Adhesion to Surfaces (Chichester, U.K.: Ellis Horwood, Ltd., 1980), pp. 559.
HONS 221672
CHAPTER 20
POTENTIAL ROLE OF GENETICALLY ENGINEERED MICROORGANISMS TO
DEGRADE TOXIC CHLORINATED HYDROCARBONS
George E. Pitre* Baticlle Columbus Laboratories Columbus, Ohio 43201
It is well known that microorganisms are capable of degrading a wide diversity of organic compounds. Microorganisms have been shown to degrade methane [1,2], fatty acids, benzene [3,4], naphthalene [5,6] and various petroleum fractions [7,8]. Many synthetic compounds, such as 2.4-dichlorophenoxyacetic add (2,4-D) [9,10]; 2.4,5-trichlorophenoxyacetic acid (2,4,5-T) [11]; DDT [12,13]; 2<hloro-4-(ethylamino)-6-(iso* propvlaminohr-triazine (Atrazine) [14]; and some isomers of polychlo rinated biphenyls (PCB) [15-17] are also degraded by microorganisms.
If environmental microorganisms are capable of degrading a diverse number of toxic chlorinated hydrocarbons, what is the purpose or reason for employing genetic engineering methods? Because of several inherent problems encountered when employing microorganisms to degrade toxic chlorinated hydrocarbons, genetic engineering may benefit microbial systems in four areas; stabilization, increased activity, multiple degradelive activities, and health, safety and environmental concerns.
315
HONS 221873
31 UOLOCICAl DETOXICATION
POTENTIAL BENEFIT OF GENETIC ENGINEERING TO MICROBIAL DEGRADATION
Stabilization
Ii has been shown that the ability to degrade some hydrocarbons is encoded on extrachromosomal DNA (plasmids) [J8.21]. These plasmids and, thus, their encoded activities can be Ion under certain conditions. Bacteria containing the TOL (toluene degradation) plasmid can lose the ability to degrade toluene if they are repeatedly subcultured on benzoate. The ability to degrade 2,4-D (Tfd plasmid) can be lost if strains are repeatedly cultured in the absence of 2,4-D [20.21]. In bacterial strains with unique degradative activities, these activities are best maintained if the compound degraded is also incorporated into the maintenance medium. However, sister cultures maintained on media devoid of the compound will often be cured of the plasmid (lose the plasmid-encoded trait permanently) after several transfers, without affecting culture via bility.
The observation that environmental microorganisms can easily lose plasmid-encoded degradative traits without affecting the viability of the population (or culture) is important. Although these plasmid elements may confer a selective advantage to the microorganisms, their main tenance is not a requirement for the microorganism (i.e., they can live equally well without the plasmid). Selective pressure must therefore be placed on the host microorganism to maintain the plasmid-encoded trait.
There are several genetic engineenng mechanisms that may be em ployed to stabilizes plasmid-encoded degradative trait. It has been shown [22.24] that hybrid plasmids can be constructed to stabilize an element. This could be accomplished by insertion of the desired element into a region where replication is under the control of a conserved element.
Increased Activity
The copy number of degradative plasmids is generally low (1-3 copies) [20], whereas the copy number of some other plasmids is higher [23,26] or can be amplified [26.27], resulting in increased protein synthesis and, ultimately, in increased activity. If the plasmid encoding the degradative trait is not amplifiable, then increased plasmid copy number could be obtained by inserting the degradative trait into a plasmid that is a high-
MONS 221874
GENETICALLY ENGINEERED MICROORGANISMS JIT
copy.number plasmid or can be amplified. It also may be possible to excise the segment of plasmid DNA that limits plasmid copy number and thus achieve an increase in plasmid copy number. Activity could also be increased by optimising the promoter location of the degradative trait [28].
Multiple Degradative Activities
The fusion by Chakrabany [29] of multiple degradative plasmids [camphor (CAM), TOL and octane (OCT)], which are incompatible plasmids, was the first demonstration of constructing a microorganism with multiple degradative traits. Recombinant DNA techniques could be similarly employed to insert elements representing multiple degradative traits into a single plasmid.
Health, Safety and Environmental Concerns
When a microorganism is considered for use in an industrial process, the potential for adverse effects should be examined and addressed. The potential for adverse effects applies equally to wild>type and engineered strains. Based on information concerning the hazards of recombinant DNA, it is unlikely that recombinant DNA techniques as applied to microbial degradation will result in any additional biohazard. In all probability, the host microorganism(s) will dictate the potential hazard.
Several techniques can be employed to minimize the potential for adverse effects. Nontransmissible plasmids are recommended, so that the potential for a plasmid to escape its host will be minimized. If the size of a plasmid can be reduced to the smallest size possible without adversely affecting the desired trait, superfluous genetic information and cryptic genes can be removed, thus reducing the possibility of transferring undesirable genetic information into the host. The host microorganism can also be enfeebled, so that it can only survive under defined conditions and is incapable of survival if it does escape. Lastly, containment systems can be constructed to limit the potential for escape of a microorganism into the environment. The additional advantages of containment devices will be discussed in further detail in the following section.
Figure 1 shows the schematic representation of an idealized degradative plasmid. In addition to those properties previously mentioned, the gene(s) of choice would be flanked by specific sequences so that additions or deletions to this region would be facilitated.
MOWS 221675
311 IIOLOGICAL DETOXICATION -----
USEFUL RESTRICTION ENZYME SITES
RISOSOME indino sm
PROMOTER
CORY NUMBER
Figurt I. Schematic repmentauon of an idealized d centda live platmid.
PROBLEMS THAT MAY LIMIT THE SUCCESS OF GENETIC ENGINEERING AS APPLIED TO MICROBIAL DEGRADATION
Although genetic engineering promises significant improvements, there are several factors that, if not taken into account, could jeopardize a genetic engineering program in the area of degradation. These are: compatibility and coordination, unfavorable environmental conditions, and adequate containment.
Compatibility and Coordination
Successful insertion of a plasmid into a pseudomonad host is no guarantee that the desired trait will be expressed. Plasmids in pseudo monads have been classified into incompatibility groups [24,29,30]. A cell containing a plasmid cannot accept a new plasmid if both plasmids belong to the same incompatibility group. The problem of dealing with incompatible plasmids can be solved by fusing the plasmids and then transferring them (as a single plasmid) to a suitable host (2B). The problem may also be addressed by constructing hybrid plasmids using recombinant DNA techniques and then transferring the hybrid plasmid to the appropriate host.
However, other problems may now be encountered that result in unsuccessful cloning and no expression of the desired trau(s). It is
HONS 221876
GENETICALLY ENGINEERED MICROORGANISMS Jl
imperative that the pathway or reactions encoded by the inserted plasmid are compatible with the biochemical pathways encoded by the host chromosome, Pseudomonas putida MT-2, which harbors the TOL plasmid, can degrade toluene [31], The TOL plasmid can be transferred to coll, but no toluene-degradative phenotype will be expressed. It has been shown in many cases that degradative plasmids are responsible for only the first several biochemical reactions of the degradame pathway [20J, while the remainder of the pathway is encoded by chromosomal genes. Therefore coli, which do not have the chromosomal genes normally found in Pseudomonas putida MT-2 (TOL*}, are unable to degrade toluene even when the TOL plasmid is present.
Coordinating biochemical pathways and their regulation mechanisms is further complicated in pseudomonads because there are three docu* mented pathways for the degradation of aromatic compounds (ortho and meta cleavage and genusaie pathways [32]}. Successful strategies there* fore must be based not only on selection of an appropriate host, but on sound genetic and physiological characterization of host and inserted element.
Environmental Conditions
A genetically engineered (or wild-type) microorganism that demon strates a high degradative ability under laboratory conditions may not be successful when used in the field. Potential reasons for failure to degrade in the field exist. Even a microorganism with a unique degradative trait, which might be considered to confer some selective advantage, would have to compete with the resident microilora to establish a permanent position in the microbial community. If the assumption is made that there are lO'-lO* bacteria per gram of soil, it can then be seen that a very large number of bacteria would have to be added to this soil to achieve a reasonable probability of establishing a "new" bacterium in the com* munity.
Assuming a "new" microorganism could be introduced and established in a given ecosystem, additional problems would also have to be addressed (e.g., temperature, pH, substrate concentration and oxygen tension). Most microorganisms have relatively well defined operating parameters. Since it is likely that at any given time one or more of these parameters are apt to be outside the optimal range for activity, the majority of the time the microorganism will have a reduced activity, (e.g., a bacterium that degrades n-alkanes optimally at 30C in an aqueous medium would most likely perform poorly if exposed to an oil spill under North Sea conditions). Because of generally unfavorable operating
MONS 221077
32S BIOLOGICAL DETOXICATION
condition! and the difficulty that is likely to be encountered in estab lishing a "new" bacterium in an ecosystem, broadcast application of genetically engineered microorganisms to treat toxic chlorinated hydro carbons is not likely to be widely successful given our current state of knowledge in this area.
Containment
It is probable that engineering systems can be fabricated to provide additional containment and a means whereby operating conditions could be controlled and optimized. Such a system could be developed and applied to aqueous treatment schemes (e.g., landfill leachate, plant effluent, holding ponds, collected runoff or municipal water). These treatment systems would most likely incorporate additional features, such as pretreatment to concentrate toxicants to levels that would support a higher microbial activity.
SUMMARY
There are considerable benefits to be derived from successful applica tion of genetic engineering to the microbial degradation of hazardous compounds and pollutants. The benefits to this area will most likely include stabilization of activities, increased rate of activity, increased spectrum of activity and development of safe microbial systems. There presently are technical restraints or problems to achieving these goals. These restraints will be overcome as better cloning-vector systems for pseudomonads and other degradauve bacteria become available. Also, with more information regarding the physiology, biochemistry and regulation of these degradaiive bacteria, the realization of these goals will come closer to reality. It must also be stated that before such successful "engineered" microorganisms are a reality, engineering information must also be integrated and developed where necessary.
REFERENCES
1. Sohngen, N. 1_ "Sur la role du methane dam la vie organique," Rrc. Trav. Chim. 29:238-274 (1910).
2. Sohngen. N, L. "Benzin. Petroleum. Panffinol und Paraffin als Kauuchuks dureh Mikroben." Zertir. Batierioi-Parastienk. Abl. 11. 40:87-98 (1913).
3. Siewan. J. E., R. E. Kailio, D. P. Stevenson. A. C. Jones and D. 0. Schislier, "Bacterial Hydrocarbon Oxidation," J. Bactenol. 78-441-448 (1959).
HONS 221878
GENETICALLY ENGINEERED MICROORGANISMS J2I
4. Dagley, S., P. J. Chapman, D. T. Gibton and J. M. Wood. "Degradation of
Benzene Nucleus by Bacteria." Nature 202 (1964).
5. Davies. J. 1., and W, C. Evans. "Oxidation Metabolism of Naphthalene by
Soil Pieudomonadi," Biochem. / 91.231-261 (1964).
6. Cerniglia, C. E..and S. A. Crow. "Metabolism of Aromatic Hydrocarbons by
Yeasts," Arch. Microbiol., 129:9-13 (19CI). 7. McKenna, E. J.. and R. E. Kallio. "The Biology of Hydrocarbons." Ann.
Rev. Microbiol. 19:183-208 (1963).
8. Walker, J. D., H. F. Austin and R. R. Colwell. "Utilization of Mixed Hydrocarbon Substrate by Petroleum-Degrading Microorganisms,"/ Gen. Appl. Microbiol. 21:27-39 (1973).
9. Bollag, J. M., C. S. Helling and M. Alexander. "2,4-D Metabolism,"/ Agrie. Food Chem. 16:826-828 (1968).
10. Loos, M. A. "Indicator Media for Microorganisms Degrading Chlorinated Pesticides," Can / Microbiol. 21:104-107 (1975).
11. Rosenberg, A., and M. Alexander. "Microbial Metabolism of 2,4,5-Tri-
chiorophenoxy Acetic Acid in Soil. Soil Suspensions, and Axenic Culture."/ Agnc. food Chem. 28:297-302 (1980).
12. Goring, C A. I., D. A. Laskowsk. J. W. Hamaker and R. W. Meiklc.
"Principles of Pesticide Degradation in Soil." in Environmental Dynamics of
Pesticides, R. Haque and V. H. Freed, Eds. (New York: Plenum Publishing Corporation, 1974). pp, 135-172.
13. Chacko, C. I., J. L. Lockwood and M. Zabik. "Chlorinated Hydrocarbon Pesticides: Degradation by Microbes," Science 134:893-895 (1966).
14. Kaufman. D. D., and P. C. Kearney. "Microbial Degradation of s-Triazine
Herbicides," Residue Rev. 32:235-265 (1970).
15. Ahmed, M., and D. D. Focht. "Degradation of Polychlorinated Biphenyls by
Two Species of Achromobacter," Can. Z Microbiol 19:47-52 1972). 16. Ahmed, M., and D. D. Focht, "Oxidation of Polychlorinated Biphenyls by
Aehromobaeier PCB," Bull. Environ. Comam. Toxicol. 10:70-72 (1973).
17. Pal, D., J. B. Weber and M. R. Overcash. "Fate of Polychlorinated Biphenyls (PCBs) in Soil-Plant Stems," Residue Rev. 74 45-98 (1980).
18. Chakrabany, A. M.. G. Chou and 1. C. Gunsalus. "Genetic Regulation of Octane Dissimulation Plasmid in Pseudomonas.' Proe. Nat. Acad. Set.. U. S.
70:1137-1140 (1973).
'
19. Reinwald, J. G., A. M. Chakrabany and 1. C. Gunsalus. "A Transmissible Plasmid Controlling Camphor Oxidation on Pseudomonas putida," Proe.
Nat. Acad. Set.. U.S. 70:885-889 (1973). 20. Fisher, P. R., J. Appleton and J. M. Pemberton. "Isolation and Characteri
zation of the Pesticide-Degrading Plasmid pJPl from Aicaiigents paradoxus," /. Becteriol. 135:798-804 (1978).
21. Pierce, G. E., T. J. Facklam and J. M. Rice. "Isolation and Charactenzation of Plasmids from Environmental Strains of Bacteria Capable of Degrading
the Herbicide 2,4-D," in Developments in Industrial Microbiology, L. A. UnderKofler, Ed. (Arlington, VA: Society for Industrial Microbiology, 1980).
22. Windlass, J. D., et al. `Improved Conversion of Methanol to Single-Cell
Protein by Methyiophiius meihylotrophus." Nature 287:396-401 (1980).
23. Bassford, F.. et al. "Genetic Fusions of the Lac Operon: A New Approach to
the Study of Biological Processes." in The Operon, J. H. Miller and W. S. Rezinikoff, Eds. (Cold Spring Harbor, NY: Cold Spring Harbor Laboratory,
1980), pp 245-262
HONS 221879
JJJ BIOLOGICAL DETOXICATION
24, Jacoby, G. A. "Classification of Plasmids in Pseudomonas aeruginosa," in Microbiology--1977, D. Schlessinger, Ed. (Washington, DC American Society for Microbiology, 1977), pp, 221-224,
23, Novick, R. P,, R. C, Clones, S. N. Cohen, R. Cuniss III, N. Dattt and S. Falkow. "Uniform Nomenclature for Bacterial Plasmids; A Proposal." Bacteriol. Rev. 40:168-189 (1976).
26. Cl*well, 0. B. "Nature of Col E| Plasmid Replication in Escherichia coil in the Presence of Chloramphenicol,' J. Bacterid. 110:667-676 (1972).
27. Chang, A C. Y . and 5. N. Cohen. "Construction and Characterization of Amplifiable Multicopy DNA Cloning Vehicles Derived from the PI3A Cryptic Miniplasmid," J. BacterioL 134:1141-1136 (1978).
28. Shine, J.. and L. Dalgarno. "Determinant of Cistron Specificity on Bacterial Ribosomes," Nature 254:34-38 (1975).
29. Chakrabarty, A. M. "Plasmids in Pseudomonas*Ann. Rev. Genet. 10:7-30 (1976).
30. Korfhagen, T. R., L. Sutton and G. A. Jacoby. "Classification and Physical Properties of Pseudomonas plasmids." in Microbiology--1971, D. Schiessinger, Ed. (Washington, DC: American Society for Microbiology, 1978), pp. 221-224.
31. Worse}', M. J., and P. A. Williams. "Metabolism of Toluene and Xylenes by Pseudomonas putlda arvilla mt-2; Evidence for a New Function of the TOL Plasmid," / Bacterial. 124:7-13 (1975),
32. Docile. H. W,, Bacterial Metabolism 2nd ed. (New York: Academic Press, Inc., 1975), pp. 499-516.
HONS 221880
CHAPTER 21
MICROBIOLOGICAL SEPARATION FOR TRACE-ORGANICS REMOVAL
Bn.ce , Rlttmann and Hester Kobayashl Environmental En|ineenn| and Science Department of Civil Engineering University of Illinois at Urbana-Champaign Urbana, Illinois 61801
Trace-level contamination by anthropogenic organic compounds is a newly discovered, but widespread phenomenon. Since surface, ground-, waste- and potable waters contain residuals of pesticides, solvents and other manmade contaminants that can have deleterious impact on human health and aquatic ecosystems, the concentrations may need to be reduced significantly. Microbiological separation is one possibility for removing trace-level organic compounds from water.
Two main mechanisms can bring about microbiological separation: biodegradation and sorption. Biodegradation is a particularly advanta geous separation process, because the polluting compounds can be mineralized completely to harmless compounds, such as COj. H20 and Cl'. In addition, biodegradation is a self-perpetuating process that does not require use of expensive chemicals, intense energy or sophisticated technology. However, biodegradation requires appropriate micro organisms in sufficient numbers and an environment suitable for their growth and metabolism. The second mechanism, sorption, does not mineralize the organic compounds; instead, the compounds are separated from the water and sorbed into or onto the microorganisms. Ultimate removal of the sorbed organic compounds is brought about by harvesting or removing the microorganisms from the treatment system for subse quent disposal or treatment.
323
HOMS
324 BIOLOGICAL DETOXICATION
This chapter describes some of the key concepts that control micro biological biodegradation. Microbiological sorption is beyond the scope of the chapter. The approach is to use three examples that represent different trace-organic problems and that illustrate different concepts and treatment approaches. Use of examples should make the concepts and possible treatment approaches more substantive and relevant. The three examples are (1) a contaminated groundwater source. (2) a contaminanted wastewater effluent, and (3) a leachate from a hazardous-waste landfill.
contaminated groundwater
Groundwater, which serves as the supply of drinking water for about 50% of the U.S. population, can be contaminated from spills, leaching and injection of harmful pesticides, industrial solvents and other compounds [1], Treatment to remove these compounds before the water is used as a water supply or before being reiqjected into the ground may be necessary in some cases. The example considered here is a groundwater having mineral and esthetic quality suitable for use as a drinking water, but also having trace-level organics that need to be reduced in concentration.
Groundwater Quality
Table 1 [2-5] gives the quality of typical groundwater found in the Midwest. After softening, this water would satisfy conventional drinkingwater standards [6] and normal water-supply practice. Because a ground water supply could become contaminated with pesticides, solvents, phenolics or other organic chemicals that are not mentioned in the drinking water standards [6], the U.S. Environmental Protection Agency (EPA) and the World Health Organization (WHO) have proposed for organic compounds the lower hazard limits listed in Table 11 [7], The hazard limits are all quite low (<] Mg/1)- and they may be reduced as more health-related information becomes available. Table II shows that contamination by hazardous organics can occur at such low concentra tions that the aggregate organic parameters listed in Table 1 could be unaffected.
NONS 221882
trace ORGANICS REMOVAL 325
Table I. tnorfanle and Orfanic Qualify of Typical Midwntani Groundwater [2-S]
Continuant
Concentration (ntf/l)
SiO.
Fe(IJl)
Ca;* Mg>
Na* K*
10
0.09
92 34
1.2 1.4
HCO,"
so:-
ci-
NO,' Toul Dittolved Solid* Total Hardneii. a* CaCO, Total Orfanic Carbon Toul Orfanic Matter Chemical Oxyfen Demand
333 *4
96
13 434 369
1.5 4.7 6.0
Table H. Propoaad Lower Haaard Limila for Selected Orfanic Compound] la Water [7]
Compound
Limit
(nf/J) per Compound
Tnhalomcthanc* and Tatnchloromaihanc Chlorinated Pesticide* <e.g,, lindane, DDT and dieldnn) Dichorobcnxenct, Chloroctlwn Penuchlorophcnol* Polynuclear Aromatic* Phenolic* Dibuiylphihateies. Diphenyl Ether, Nitrotoluenc Other*
1 0.1 1 1 0.1 1 1 0.1
Concentrations in excess of the hazard limits can be found in otherwise good quality groundwater. For example, Roux and Althoff [8] reported that 1.1 ,|-trichloroethane. tetrachloroethylene and other related com pounds contaminated groundwater, including the public water supply, at concentrations up to 1000 pg/1. Although the aquifer supplying drinking water was deep, windows in the aquaciudes allowed these organic
HONS 221083
32* BIOLOCICAL DETOXICATION
contaminants to travel from industrial plants to the drinking water supply. Lang et al. [9] reported the following groundwater concentre* tions: vinyl chloride. 13.1 pg/l: /ra/w-,2-dichloroethylene, 1.5 ml\: cis~ 1.2-dichloroethylene. 29 pg/1; 1 .trichloroethylene, 1.0 pg/l; trichloro ethylene. 0.34 pg/l;and tetrachloroethylene. 1.2ml I- Clearly, otherwise acceputb1* groundwaters have become contaminated with hazardous organic chemical) present at I- to 1000-/4$/1 concentrations.
Key Factors for Biological Separation
Many of the compounds that can contaminate groundwaters are biodegradable. Recent reports in the literature have presented evidence that the following industrial chemicals can be biodegraded: tetrachloroethylene, l.l-dichloroethylene, 1.2-dichloroethylene, vinyl chloride, 1,1,1trichloroethane, chloroform, methylene chloride, carbon tetrachloride, chlorobenzene, dichlorobenzene, naphthalene, styrene, bromo-and eh lo romethanes, 1,1,2-irichloroethane, 1,1,2-trichloroethylene, and 1.1.2,2tetrachloroethane [9-13]. It is well known that most of the pesticides can be at least partially degraded [14], Although many compounds are biodegradable, having been biodegraded under laboratory or field condi tions does not guarantee that a compound will be biodegraded when present in groundwater.
Two interrelated factors control how well biological processes can achieve trace-organics separation in a groundwater. The first factor is the concentration of organic matter. Low concentrations l.mu the amount and type of biological activity that can occur. The second factor is the availability of solid surfaces. When organic substrate concentrations are low, the predominant form of microbial activity ts found attached to solid surfaces as biofilms [15,16].
Table 1 shows that little organic matter is in typical groundwater supplies, and the readily biodegradable portion of that organic material is often only a small fraction of the total [17], Thus, the potential for growing and sustaining microorganisms through organic-substrate utili zation is not great. Rittmann and McCarty [IS] developed a model of biofilm kinetics especially appropriate for cases like contaminated groundwater. The model simultaneously considers mass transfer of substrate from the bulk liquid to the surface of the biofilm. diffusion of substrate through the biofilm, utilization of substrate by the bacteria within the biofilm. growth of the biofilm due to substrate utilization.and biofilm losses due to decay. Figure 1 illustrates that the model of a stead}-
HONS 221884
TRACE ORGANICS REMOVAL 327
state biofilm predicts that the biofilm mass and reaction rate decline rapidly to zero as the substrate concentration approaches! limiting value
which can be predicted from fundamental kinetic parameters:
b
sTM. * K, ^777
(I)
where
K, * Monod half maximum-velocity concentration <M,/L') Y - true yield k maximum specific substrate utijiiation rat* (M,/Mt T) b = first-order decay or biomass-loss coefficient (T1)
At substrate concentrations less than S^,,, the biofilm loss rate is greater than the biofilm growth rate, and any biofilm present will decay away. Hence steady-state biofilms can not persist when substrate concentration is always less than Sn,m.
LOG*, S Ftfure t. Example of relationship of steady-state biofilm thickness (Lf) <0 substrate
concentration (S).
HONS 221885
ACETATE, m g/l
DICHLOROMETHANE,mg/l
321 BIOLOGICAL DETOXICATION
2 4 6 8 10 DISTANCE ALONG REACTOR, cm
PIfur* 2. Removal of acetate and dtehloromethene in itcad.wtaic biofilm reacton Rcacton wit 12 cm long 13 cm dtam, and the biofitm support medium was ?-mm flaai bead*. T > 20* C.
Experiments with once-through biofilm reactors have demonstrated Smin* Figure 2, taken from the work or Rittmann and McCarty [10.19], shows that substrate concentrations leveled off at Smn values when acetate, a common metabolite, and dichloromethane, a widely used
HONS 221886
trace orcanics removal m*
industrial solvent, were used as substrates in separate reactors. Typical values for Snm obtained for aerobic biodegradation of various organics range from about 0.1 to 1.0 mg/1 [10, 19, 20].
The limitation of Smin seems to suggest that compounds already present at concentrations less than typical SmM value may be impossible to biodegrade. However, two further concepts present ways in which biodegradation can occur. The first possibility is selection, enrichment and application of specially adapted oligotrophic bacteria, which have advantages and can survive in very low-concentration environments. Oligotrophic bacteria use an efficient metabolism and a high affinity for substrates, and these characteristics allow the oligotrophs to survive and function when other bacteria die or remain dormant. Although oligotrophs have been studied very tittle, some attributes of bacteria that have shown oligotrophic characteristics were recently compiled [21]. The outstanding features include extremely efficient uulizauon of multiple and varied compounds, constitutive production of transport enzymes with high affinity for catalyzed substrates, inducible enzymes for catabolic pathways and relatively slow maximum growth rates. The high affinity for substrates would be mostly detected as a very low K, value. Equation 1 show's that oligotrophic, biofilm-forming bacteria could have SMM values in the I-Mg/i range if K, were reduced sufficiently.
Since little work has been performed with freshwater oligotrophic bacteria, their potential usefulness in trace-organic removal is speculative. Bask questions have only begun to be asked. What strategies give oligotrophs their advantage at low concentration? Can bacteria with appropriate metabolic functions be adapted to oligotrophy? What is the minimum concentration of a given substrate to which oligotrophic bacteria are adapted? How can oligotrophic bacteria be best cultivated and used?
A second and better-studied possibility for trace-organics removal when substrate concentrations are already less than Sn, is called secondary utilization. Secondary utilization is defined as the utilization of a substrate, called the secondary substrate, which does not supply sufficient energy or carbon for the cells* growth and maintenance [20.22.23]. Cometabolism, the partial transformation of substituted analogs of primary substrates, is a subclass of secondary utilization. A compound present at <S,,,in concentration is an excellent example of a secondin' substrate, since the reason that no bioftlm exists for concentrations less than Smia is that the rate of energy capture through substrate utilization does not supply enough energy to meet even maintenance requirements. Secondary substrate utilization can and does occur, however, if the biofilm is ,'rown and sustained through utilization
MOMS 221887
33* BIOLOGICAL DETOXICATION
of a primary substrate, which is present at suitably high concentration to support the bacteria. The primary substrate can be one compound or an aggregate of many compounds. In fact, the primary substrate can be the composite of many secondary substrates, none of which could sustain the biofilm alone.
Figure 3 gives a relevant example of how secondary utilization can work. A biofilm was grown using a feed medium that consisted of laboratory deionized water plus mineral nutrients. No organic substrate was added, and a biofilm was sustained through utilization of about 0.17 mg Cl 1 out of a feed total organic carbon (TOQ of 0.59 mg/1. When sodium acetate was added to the feed, it was removed to concentrations well below Sfflul (about 30 jig/ i) as shown in Figure 3. The substrate was a mixture of many organics, and might be representative of the natural organics found in a clean groundwater.
For treatment of a contaminated groundwater through secondary utilization, the naturally occurring organic compounds may be able to serve as the primary substrate. On the other hand, it may be necessary in some cases to supplement the water with a primary substrate to ensure that sufficient bacterial growth occurs. When treating a contaminated groundwater that could be used as a potable source, added materials must be chosen carefully so that they are not harmful themselves and do not cause undesirable taste, odor or color. Simple metabolites seem most appropriate.
Although secondary utilization is a demonstrated and promising concept for trace-organics removal, ii raises some questions and has some drawbacks. The first question concerns the availability of suitable primary substrate to allow growth of bacteria capable of biodegrading the hazardous pollutants. Experiments were carried out to ascertain if biofilm bacteria grown on a given primary substrate could also utilize other secondary substrates [20], Figure 4 presents typical data from these experiments. The secondary substrates were fed for only a short time, while the biofilm had been grown for the long term on only the primary substrtte, thymine. Although alanine and acetate, both common metabolites, were readily utilized by the thymine-grown biofilm, phenol and galactose were largely unutilized. Thus, not all compounds can serve as primary substrates for bacteria that can metabolize a potential secondary substrate. For the exotic, anthropogenic compounds, finding an appropriate primary substrate naturally occurring in ihe ground water or io add to the water may be difficult; research along this line is continuing,
A second and closely related problem is that very' low concentrations of anthropogenic compounds may not be as easily degraded by bacteria as
MOWS 221888
TRACE ORGANICS REMOVAL 331
O* 3.
I
tZ
Id
i
i i 1 i i i
i
v * 322 cm/doy
Id
Id
I 2 3 4 5 6 7 8 9 10 II 12
DISTANCE ALONG REACTOR, cm
Figure 3. Secondary utilization of occult by bioTilm bocient frown on residual organics in laboratory deionized aatcr plus minerals. T * 20*C.
are high concentration*. Boethling and Alexander [24] reported that 2,4* Dand l-naphthyl-A'-methylcarbamate plus l-naphthol (Sevin*) were not biodegraded at concentrations below 2.2 and 30 mS/I> respectively, although they were degraded at higher concentrations. Rittmann et al, [II] showed a similar threshold effect for dichloro* and chlorobenzenes present below about 100 mS/I- These apparent threshold effects, which
MOMS 221889
332 BIOLOGICAL DETOXICATION
2 4 C B 10 LENGTH ALONG REACTOR,cm
Flpn 4 Rtmovml or secondary sublimes and primary substrate by biofilm frown with
thymine as primary mbit rate. T>22*C;r>6IO cm/day.
show no degradation below some low concentration, may be caused by a lack of enzyme induction or activation when little substrate is available. Somewhat similar effects were reported for common metabolites, such as starch (25 m|/1), glycerol (20 mS/ I), gluconate (10 nil I), and mannitol (20 Mg/I) [25). The mechanisms for such thresholds are unknown, but existence of thresholds in the l- to 100-Mg/1 range could severely hamper application of biodegradation by secondary utilization. Fortunately, work by Bouwer and McCarty [26] showed secondary utilization of chlorinated benzenes present at about 10 Mg/1 w-hen a primary substrate, acetate, was also continuously present. Perhaps the presence ofa primary substrate allows continued genetic expression and enzyme activity; more work 's necessary in this area.
HONS 221890
TRACE ORGANICS REMOVAL 333
Two important engineering decision can affect process performances: selection of biofilm support media and reactor configuration. Biofilm growth can occur on many surfaces, including glass beads, sand, carbon, metal oxides and plastics. For removal of trace-level organics, activated carbon seems to offer numerous advantages over other surfaces. One key advantage seems to be an enhancement of bacterial surface attachment, especially for very thin biofilms that experience high shearing stresses [27-29]. The reasons for improved attachment are related to the creviced and hydrophobic nature of the activated carbon surface, but the quantitative extent of such an advantage remains unknown.
A second advantage of using activated carbon as biofilm support medium is that the activated carbon adsorbs and stores solutes that are not immediately biodegraded. This storage is probably advantageous to the formation of a biofilm, since more substrate is available to the organisms at the surface, and this can help reduce S,,,* limitations during biofilm inception and growth. Backdiffusion and biodegradation of sorbed organics (termed bioregeneration by those interested in the adsorption capacity of activated carbon) have been demonstrated to be important [30-22]. Adsorption of organic solutes by carbon is also advantageous in another way. A compound that escapes biodegradation because it is nonbiodegradable by the biofilm or because its mass loading exceeds the capacity of the removal kinetics of the biofilm can be adsorbed to the carbon. The adsorption reduces the concentration of the process effluent and sufficiently retards the compound's travel through the reactor (the chromatographic effect) so that the bacteria have an increased opportunity to degrade the compound.
Selection of process configuration is also an important choice that can affect overall process performance. In water and wastewater treatment practice, activated carbon reactors, which are not necessarily used for biodegradation, are operated in fixed* and Duidized-bed modes. From the viewpoint of biodegradation of low concentrations of organic compounds, the fiuidized-bed reactor can offer numerous advantages over the fixed-bed reactor. Rittmann [33] has shown how fluidization of the biofilm support medium reduces the S,,,,,, restrictions on biofilm growth by uncoupling the steady-state mass of biofilm present at any point in the reactor from the substrate concentration at that point. The advantage of a fluidized bed comes about like this: in a fluidized bed reactor, the solid medium is expanded and well mixed throughout the reactor, which means that a panicle of biofilm is sometimes near the inlet, where substrate concentration is high, and sometimes near the outlet, where substrate concentration is low. Rittmann [33] demonstrated that mixing and periodic exposure to the high substrate concentration near the
MOHS 221891
334 BIOLOGICAL DETOXICATION
inlet allow the greatest total biofilm mass throughout the reactor and distribute the biofilm evenly, which increases the biofilm's effectiveness. In other words, fluidization allows biofilm to grow near the inlet and be transported near to the outlet, where it brings about substrate removal, even though the outlet substrate concentration is already less than S*,,,.
Figure 5 gives an example of how fluidization can improve process performance [33]. The teed concentration and detention time are the same
F1|ur 5. Comparison of predicted process performance for biofilm reactor conftgura* lions. S* * 3 3 mg/1: <* s 500 cm/day: Y * 0.142 mg VSS/f; b* 0.205 day'1, D * I.M cm:/da>", D, = 0 17 cmJ/day: df 3 mm; T * 20*C. MOWS 221892
TRACE ORGANICS removal 335
for each reactor, but the fluidized-bed reactor reduced the effluent concentration to about 0.1 mg/ lt while the fixed-bed reactor reduced the concentration to Sm;B, about 0.7 mg/1. The improved performance of the fluidized-bed reactor occurred because the biofllm mass was spread out evenly throughout the reactor, while the liquid flowrate was still rather "plug How." In this way, the best conditions--liquid plug flow, bm uniform biofilm distribution--bring about the maximum substrate removal [33].
Figure S also shows that adding recycle, which may be necessary for fluidization in some cases, begins to transform the nature of the liquid flow from plug flow into complete mix. Since complete-mix (liquid flow) reactors give the smallest substrate removal, use of recycle should be minimized. A recycle ratio (QR/Q) of about 10 results in a nearly complete-mix regime and negates the benefits of fluidization [33]. Fortunately, activated carbon has a low mass density and often can be fluidized without using excess recycle, provided the detention times are less than a few hours.
Despite its advantages, fluidized-bed technology will not work if the Smia requirement is not met in the influent. Secondary utilization, possibly including primary substrate supplements, is necessary for flu idized bed .removal of trace-level organic contaminants. If there is sufficient primary substrate in the influent, fluidized beds obtain the best performance. On the other hand, fluidization does not allow growth when there is no primary substrate.
wastewater effluent
Effluent Quality
The effluents from municipal and industrial wastewater treatment processes can contain significant concentrations of hazardous organic chemicals. The sources of these chemicals include direct discharge into the sewers, accidental spills, leakage into the sewers through infiltration and production during chlorination. Although some of these compounds are removed by biodegradation, sorption or air stripping during conventional wastewater treatment, many compounds persist in the effluents.
Table 111 [34-37] lists some concentrations of anthropogenic com pounds detected in wastewater effluents. All are less than 100 ug/1. but many compounds are well above the proposed hazard limits (see Table
HONS 221893
334 BIOLOGICAL DETOXICATION
TeWe III. ConcrntritloiTt of Afilbropo|tnk Compound* Detected in Municipal Wgiltwafer* Treatment Effluent*
Compound
Chlorobenzene l.2*Dtchlorobenzene i .3* Die hlorobenzene 1, 4* Dichloro benzene Sum of Die hlorobenzene* 1.2. 4*Trie hiorobe nzene Sum of Trrdtlorobcnzene* Naphthalene Styrene Benzonitrile Chloroform Dichlorobromomcthane Chlorodtbromomet hane Bromoform Dichloromethane Trichloroethylene TeimchlorocthyleM 1.1,1 -TricMoroethane 1.1,2-Trichloroethylenc Lindane /m'-ddd
Concentration
o*/t>
4.1, 0.9 1.9, 2.0 0.6,0.3 0.S.2.0
S.6 0.5.0.2 57. 0.9. 0.2
4.7 12. 2.5. 7.1 0.2 2.2 0.5 2.4, 2.9, 2.5-S.4 1.5 1.3. 3,9 6.3, 9.0 1.6 0.03-0.01 0.13
Reference
34.33 34.33 34 JS 34.35
36 34.35
36 34J5
34 34 35.36 35 35 33 33-37 33 35.36 35.36 36 37 37
II). Although wastewaters are seldom reused directly for potable water, they frequently are indirectly reused after discharge to a surface receiving water or recharge of a groundwater aquifer. In addition to possible harmful effects from indirect human consumption, these compounds can damage aquatic ecosystems.
After secondary wastewater treatment, a wastewater effluent has quality characteristics that classify it as a low-concentration medium. The typical chemical oxygen demand (COD) and TOC of an effluent are about 30 and 10 mg/1, respectively. Although greater than those found in most groundwaters, the organic concentrations of wastewater effluents are still low, and biological growth is still limited. Some years ago, efforts were made to characterize the chemical constituents of sewage and sewage-treatment effluents. The results of the characterizations give an idea of what types of potential primary substrates are available.
MONS 221894
TRACE ORGANICS REMOVAL 337
Table IV, Concentration Ran|cs for Or|ink Claaaaa Commonly Preaent In Effluenti from Biological Wartewiter Treatment
Glut
Protein/Ammo Acids Fitly Acid Detergents Carbohydrates Ether Extractable* Humic Acids Fulvic Acids
Sum
Range (mg/I as COD)
0'S 200 M IO io 2-4 6-9
13-64
Reference*
31-42 0-46 31.41.42.45 41,42.46 41,42 41,42,46 41,42.46
Table V. Chemical Breakdown of Typical" Effluent After Biological Wastewater Treatment
Chemical Cbm
Proteins/Amino Adds Fatly Acids Detergents Carbohydrate Ether Exiractables Humic Adda Fulvic Acids
Sum
COD <*/t)
3 9 2 2 3 5 6
30
Table IV [38-46] summarizes the conceniraiion ranges for the chemical classes normally found in wastewater treatment effluents. The wastewater effluents represented in Table IV had rather widely ranging total organic concentrations. Table V gives a breakdown of the organic classes for a "typical" effluent having a soluble COO of 30 mg/1. Table V was derived from the data in Figure 4 after adjustments were made for the different strengths. Most of organic material seems to be organic acids, which are common metabolic intermediates, and humic and fulvic acids, which are the biologically resistant products of natural decay. The values in Tables IV and V suggest that the most likely primary substrates naturally occurring in wastewater effluents are the organic acids, which amount to about 9 mg/1 as COD in a "typical" effluent.
HONS 221895
331 BIOLOGICAL DETOXICATION
Biological Separation Processes
As long as the bacteria grown on the primary substrate can also utilise the anthropogenic compounds of interest, a typical sewage effluent should have sufficient biodegradable organic material to carry out secondary utilization in aerobic systems. Utilization of activated carbon media and/or a fluidized-bed configuration should enhance removals and reduce the hazardous compounds to sub-/*g/ i levels.
Natural organics seem to be adequate primary substrates for secondary utilization of many trace contaminants [20,23,26]. On the other hand, other compounds pass through the biological systems largely or com pletely undegraded. If, therefore, the contaminants of interest are not biodegraded by the naturally selected microorganisms, special considera tion must be given to supplying a primary substrate. Perhaps in such cases the only workable primary substrate is the contaminant itself. For the groundwater example, it would be totally inappropriate, if not illegal, to add a hazardous compound to the water to promote biological growth, as a failure in the system could result in a seriously contaminated water supply. In some cases this restriction may not be necessary for wastewater treatment.
Adding a compound to the water for the purpose of promoting growth of bacteria able to degrade that compound can be effective for achieving very low effluent concentration only through use of a nonsteady-staie technology. A nonsteady-state biofilm reactor is one in which the biofilm in the reactor undergoes net growth or decay, and it is different from the previously described steady-state reactors, in which biofilm growth is continuously balanced by losses. Operated in a nonsteady-state mode, a biofilm reactor is fed a high-concentration feed fora relatively short time, such as one week. During that time, the biofilm grows to a relatively large thickness. Subsequently, the normal, low-concentration feed is applied. Since the large biomass is already present and its decay and other losses are typically much slower than was the growth, the biofilm can utilize the input substrate for a relatively long time, even though the feed concentra tion is less than S*,*. Once biofilm losses have reduced the biofilm's capacity to an unacceptable level, the cycle is repeated. A biofilm operated in this mode is nonsteady-state because it grows when the high concentration feed is applied and decays when the low-concentration feed is applied. To operate such a system, several parallel units would be required; while one unit would be in the growth mode, the other units would be treating the wastewater.
Figure 6 [47] illustrates how nonsteady-state operation was able to achieve effluent concentrations well below Sm,n. The biofilm was grown
HONS 221896
TRACE ORGANICS REMOVAL 339
0.8 r
07
06
2 o 05
< cc
0.4
oLU 0.3 o Q2
0.1
0 0 2 4 6 8 10
DISTANCE ALONG REACTOR, cm
Figure 1 Noimeady**iate biofilm reduction of acetate concentration to below S,,,, when influent concentration it reduced from 7.6 to 0.76 mg/1 of acetate. T * 20*C; * 400 cm/day [47J.
with a feed acetate concentration of 7.2 mg/1, which grew a biofilm capable of reducing the effluent concentration to Smi,. about 0.66 mg/1. When the feed concentration was reduced to 0.72 mg/1, the biofilm. already present, was able to reduce the effluent concentration to 0.1 mg/1 or only about 15% of S**,. Even lower concentrations could be achieved if the feed concentration were lower.
LANDFILL LEACHATE
Quality Characteristics
The quality of landfill leachate is as varied as the material that is disposed of in landfills. A noteworthy example is the leachate collected from the southern sector of the Love Canal landfill site at Niagara Falls. New York [48]. Table VI lists selected characteristics of the Love Canal leachate.
Compared to the groundwater and wastewater effluent examples, the Love Canal leachate is about 400-4000 times more concentrated in terms
HONS 221897
34S BIOLOGICAL detoxication
Table VI. Selected Characteristics of Landfill Leachate from Lorn Canal [41]
Parameter
Value
pH TOC COD Total Dissolved Solids Sulfite Sulfide Total Phosphate, at P Sodium Calcium Iron Methanol Toluene Chtoroioluene Benzene Chlorobenzene Benzyl Alcohol Chlorobenzyl Alcohol Phenol Chlorobenuldehydes
3.6 4.300
11.300
13,700 2*0
0.1 0.1 1.000
1.300 330 19 39
26 14.3 12
29 26 II
26
'Except pH
of total and specific organics. Problems of trice levels would seem to be eliminated, since more than ample COD is available for growing bacteria. Even anthropogenic compounds are present at fairly high concentration. However, many trace-level compounds are present in the leachate, and the ultimate treatment goal is still to reduce the concentration to lessthan-hazardous levels.
Biological Separation Processes
The first factor in treating leachate is that it must be contained and treated in a controlled reactor. First, the leachate cannot remain in the ground, because it may escape and seriously contaminate a groundwater aquifer. Second, a treatment reactor is necessary because successful treatment is very unlikely in situ. The problems with in situ treatment are numerous: (I) the microorganisms are not well distributed and will not adequately come into contact with leachate spread under many hectares of landfill; (2) gas production (CH4, COj. H:S) in the landfill can create
MONS 221898
TRACE ORGANICS REMOVAL Ml
dangerous explosion and unstable land conditions; and (3) little or no process control over temperature, pH, and electron acceptor can be effected. Therefore, in situ treatment is an unreliable alternative.
The most promising biological treatment scheme for landfill leachate involves anaerobic methanogenesis. A methanogenic process is advanta* geous for five obvious reasons:
I. The leachate is already tnaerobic. I Meihanogenic processes require no aeration to supply oxyftn- To supply
enou|n oxygen to meet the oxygen requirements of aerobic activated sludfe treatment of the Love Canal leachate would cost about $0.40/mJ of leachate, not including capital recovery. 3. The anaerobie process produces 10-20 times less biological sludge than would an aerobic process. Low sludge production means major cost savings, sinet sludge handling and disposal for aerobic operations typically requires half of the operating budget. 4. The lack of sludge production during meihanogenests means lhat nutrient additions (N and P) can be relatively low. Table VI shows that the Love Canal leachate has no P and probably lilllc inorganic N. Aerobic treatment would require addition of about 3401 N/mJ and 70 g P/m\ while (he requirements with anaerobic treatment would be 10-20 times let*. i. Meihanogcnesit produces a valuable product, methane gat. which can easily be captured and used to run pumps or equipment, heat buildings, or generate electricity. The methane gat produced through anaerobic treatment of Love Canal leachate would generate about $0.60/ra1 of electrical power.
Besides the obvious benefits of methanogenesis, the anaerobic process can be the most appropriate for leachate decontamination because degradation of certain anthropogenic organics is enhanced in the anaerobic environment. For example, the breakdown of chlorinated hydrocarbons is greatly increased in an anaerobic environment [50.51], wnere the original organic matter, metabolic products (such as reduced flavins) and reduced inorganics (such as iron and sulfur) serve as electron donors and electron-transfer agents. The result is that chlorinated hydrocarbons are reductively dechlorinated, with hydrogen replacing the chlorine. Since the dechlorination step often limits biodegradation of chlorinated compounds, the anaerobic environment is often ideal for enhancing biodegndation of many of the most critical contaminants.
Numerous reports [13,50-53] have shown that degradation of halogenated hydrocarbons requires an anaerobic environment. Partic ularly pertinent is the work of Bouwer et al. [13], in which low concentrations (less than I mg/1) of halogenated one- and two-carbon hydrocarbons were degraded anaerobically, but not aerobically. Even without biological activity, the brominaied compounds were dehalogenaied, although not nearly as quickly as with methanogenic activity; others have also shown that strongly anaerobic conditions can bring
MOMS 221899
341 BIOLOGICAL DETOXICATION
about reductive dehalogenation when microbial activity is not present [50,51], and dehalogenation is correlated to a negative Eh- Thus, the use of an anaerobic treatment process enhances microbiological and possibly chemical degradation of many of the contaminants of most concern.
It must be pointed out that halogen-substituted aromatic rings seem to be resistant to anaerobic attack, but require aerobic hydroxylation to dehalogenate them [50], Recent work at very low concentrations [11,13] has reinforced this idea: halogenated hydrocarbons were degraded anaerobically, but not aerobically; chlorinated aromatics were degraded aerobically, but not anaerobically. Should anaerobic dehalogenation of aromatic compounds be found feasible in the future, the anaerobic system should be capable of completely degrading the resulting aromatic products [54],
Methanogenic processes have been used for treating high-strength industrial wastes, as well as sewage sludges..The anaerobic filter [49] has been gaining popularity because it offers the advantages of a fixed-film system: process stability and high loading rates. It has been used to treat wastewater resembling hazardous landfill leachate. DeWalle and Chian [55] used a fixed-bed, complete-mix anaerobic filter to treat a landfill leachate having a COD of 32,000-54,000 mg/1, and they reduced the COD to 1000 mg/1 with a 7.5-day detention time at 25*C. Suidan et al [30] treated high strength phenolic wastewater with a fluidized-bed anaerobic filter at 35* C
A most important factor for use of anaerobic filters is the chemical characteristics of the wastewater, since certain characteristics could cause operating problems. The first problem is toxicity. Numerous inorganic compounds that can be present in leachate are toxic to methanogens [56]. Among the most likely to be problems are sodium, sulfur and heavy metals. An excessive sodium concentration, such as 3500 mg/1 or more, is inhibitory to methanogens, and more than 8000 mg/1 can be strongly inhibitory or toxic. Reduced sulfur compounds in solution--HjS, HS' and S1*--are toxic at 200 mg/1, while soluble heavy metals, such as Cd. Zn and Nt, are toxic at mg/1 levels. If the metals and sulfur are reasonably well balanced in the feed, metal sulfides precipitate in the anaerobic system, rendering both types of toxics harmless. Too great a quantity of sulfur or metals, which could easily occur in a leachate, would create toxic conditions preventing the methane-producing bacteria from functioning properly.
Organic materials, such as found in leachate, can also be highly toxic, and thetr toxicity often occurs at low concentrations. For instance, chloroform is toxic at 2-100 mg/1, cyanide at 1-200 mg/1, methylene chloride at 20 mg/1. and ethylene dichlonde at 32 mg/1 [57,5S]. In some
MQNS 221900
TRACE ORGANICS REMOVAL 34)
cases, the anaerobic systems seem to acclimate, but acclimation is not the rule.
The second problem with methanogenic treatment is pH control, in its essence, anaerobic treatment is a two-step process. In the first step, anaerobic bacteria break down complex organic compounds through fermentative pathways, producing mostly short-chain organic acids, COj and Hj. In the second step, methanogens utilize the first-stage products and produce methane gas. Treatment, or COD removal, occurs because the electron equivalents of the original organic matter end up in methane, which is easily stripped from the water. If the methanogens are unable to utilize the acids produced during the First stage as fast as they are produced, the buffering capacity of the system is neutralized by the acids and the pH falls. Since methanogens are sensitive to low pH, a decrease below about pH 6.5 still further slows the methanogenic reaction and hastens the ultimate failure of the system.
The anaerobic process is appropriate for leachate treatment because (1) the leachate is already anaerobic and has enough organic material to sustain anaerobic conditions; (2) it enhances degradation of many con taminants; and (3) it can make treatment an energy-producing enterprise. On the other hand, anaerobic treatment may not be able to degrade certain aromatic compounds, and it may not produce an effluent with suitably low concentrations of total organics or specific compounds. A prudent approach is to follow anaerobic treatment with a simple aerobic process, such as a routing biological conuctor (RBC) [59,60]. The anaerobic unit provides most of the COD removal, while the aerobic system polishes the effluent and removes compounds unaffected by the anaerobic process. Costs of aerobic treatment are minimized because most of the COD is removed during anaerobic treatment.
SUMMARY
Biodegradation of anthropogenic organics present in waters is a complicated and not very well developed field. However, several factors are clear. When the contaminants are at very low concentration, special consideration must be given to providing enough energy for the bacteria to sustain themselves in the system. Biofilm processes seem most appro priate, since the bacteria are kept in the reactor by attachment, and biofilms predominate naturally with low concentrations. Secondary utilization, nonsteady-state operation, and activated carbon attachment are methods to promote bacterial growth when concentrations are very
HOMS 221901
344 BIOLOGICAL DETOXICATION
low. ]n combinttion with these three methods, fiuidized-bed treatment offers advantages for obtaining very low effluent concentrations.
For landfill leachate, which is often anaerobic and contains rather high organic strength, anaerobic methanogenic processes offer the benefits of decreased operating costs and enhanced degradation of many hazardous contaminants. Caution must be exercised to prevent toxicity to the anaerooic microorganisms, and posttreatment with a simple aerobic process may be necessary to polish the effluent and degrade halogenated aromatics.
Although some concepts and techniques are known today, much basic information about biodegradation of trace-level organics is tacking, such as:
physiological response of bacteria to very low concentrations of substrates: relationship between primary anti secondary substrates: toxicity of trace-level organics to biological processes: ability to apply treatment concepts to realworld applications: consequences of partial degradation; and interactions among communities of microorganisms necessary 10 completely degrade
compounds.
ACKNOWLEDGMENT
This project was financed entirely with federal funds as part of the program of the Advanced Environmental Control Technology Research Center, University of Illinois at Urbana-Champaign, which is supported under Cooperative Agreement CR 806819 with the Environmental Pro tection Agency. The contents do not necessarily reflect the views and policies of the Environmental Protection Agency, nor does the mention of trade names or commercial products constitute endorsement or recom mendation for use.
REFERENCES
]. Geraghtv, J. J.. and D. W. Miller. `Status of Groundwater Contamination in the U.S.," J. Am. Water Workt Assoc. 70(3):!62(J978).
2. Snoevtnk, V. L, end D. Jenkins. Water Chemistry (New York: John Wiley and Sons, Inc., 1980), p. 6.
3. Brass. H. J.. M. J. Meitner and B. A. Kingsley. `Community Water Supply Survey: Sampling and Analysis for Purgeable Organics and Tout Organic Carbon," paper presented at the Annual Conference of the American Water Works Associttion. St. Louis. MO. June 9. 1981.
4. Robinson, L. R.. J. T. O'Connor and R. S. Engelbrecht. "Organic Materials in .liinois Ground Waters." J. Am. Water Works Assoc, 59 327 (1967).
MONS 221902
TRACE ORGANICS REMOVAL MS
5. Hughes, J, L, L A. Ecoies and R. L Malcom, "Dissolved Orpnic Carbon (DOO, an Index of Organic Contamination in Ground Water Near Barstow, California," Ground Water 12(5):283 (1974).
6. "Raw- Water Quality Criteria for Public Supplies," Federal Water Pollution Control Administration, National Technical Advisory Report, U.S. Govern* ment Printing Office. (1968).
7. van Rensburg, J. F. J.. A. Hassett, S. Theron and S. G. Wjechers. "The Fate of Organic Micropoilutants Through an Integrated Wastewater Treatment/ Water Reclamation System," Prog. Water Technoi. 12:537-552 (1980).
8. Roux, P. H., and W. F. Althoff. "lnvestiption of Orpnk Contamination of Ground Water in South Brunswick Township, New Jersey," Ground Water I8(5):464-471 (1980).
9. Lang, R. F., P. R. Wood, F. A. Parsons. J. DeMarco, H. J. Harween. I. L. Payan, L M. Meyer. M. C. Ruiz and E. D. Ravelo. "Introductory Study of the Biodegradation of the Chlorinated Methane, Ethane and Ethene Com pounds," paper presented at the Annual Conference of the American Water Works Association, St. Louis. MO. June 19, 1981.
10. Rittmann, B. E., and P. L McCarty. "Utilization of Dichloromethane by Suspended and Fixed-Film Bacteria," Appl. Environ. Microbiol. 39(6): 1225-1226 (1980).
11. Rittmann, B. E-, E. J. Bouwer, J. E. Schreiner and P. L. McCarty. "Biodegradation of Trace Orpnic Compounds in Ground Water Systems" Technical Report No. 25S Department of Civil Engineering. Stanford Univeristy, (Stanford, CA) (1980).
11 Jensen, S., and R. Rosenberg. "Degradability of Some Chlorinated Aliphatic Hydrocarbons in Sea Water and Sterilized Water" Water Res. 9:659 (1975).
13. Bouwer. E. J., B. E. Rittmann and P. L. McCarty. "Anaerobic Degradation of Haiogenated 1* and 2-Carbon Organic Compounds," Environ. Sci. Technoi. 15(5):596-599 (1981).
14. Alexander, M. "Biodegradation of Chemicals of Environmental Concern," Science 211:132-138 (1981).
!5. ZoBeil. C. A. "The Influence of Solid Surface upon the Physiological Activities of Bacteria in Sea Water." J. Sactertol. 33:86 (1937).
16. Wuhrmann. K. "Stream Purification." in Water Pollution Microbiology, R. Mitchell. Ed. (New York: Wiley-1 ntcrscicnce, 1972).
17. Grigoropoulos, S. G., and J. W. Smith. "Trace Orpnica in Missouri Subsurface Waters."./. Am. Water Works Assoc.. 60:586 (1968).
18. Rittmann. B. E., and P. L. McCarty. "Model of Steady-Staie-Biofilm Kinetics." Bioieehnoi. Bioeng. 22(1 l):2343r2358 (1980).
19. Rittmann, B. E., and P. L. McCarty. "Evaluation of Steady-Staie-Biofilm Kinetics." Biotech. Bioeng. 22( 11 ):2359-2374 (1980).
20. Stratton. R,, E. Namkung and B. E. Rittmann. "Biodegradation of Trace Orpnks by Biofllms on Porous Media." paper presented at the Annual Conference of the American Water Works Association, St. Louis, MO, June 10. 1981.
21. Hinch, P.. ct si. "Life Under Conditions of Low Nutrient Concentrations. Group Report." in: Strategies of Microbial Life in Extreme Environments M. Shilo. Ed. (Berlin, FRG; Dahlcm Konferenzen, 1979). pp. 257-372.
22. McCarty, P. L.. B. E. Rittmann and M. Reinhard. "Processes Affecting the Movement and Fate of Trace Organics in the Subsurface Environment" Environ. Sci. Technoi. I5(I):40-5I (1981).
HOMS 221903
344 BIOLOGICAL DETOXICATION
23. Rittmann, B. E-. P. L. McCarty and P. V. Robcru, "Trace-Organics
Biodegradation in Aquifer Recharge,** Ground Water J8{3):236-243 (1980). 24. Boethlmg, R. S., and M. Alexander. "Effect of Concentration of Organic
Chemicals on their Biodegradation by Natural Microbial Communities," Appi Environ. Microbiol. 37(6): 1211 (1979). 23. van der Kooij. D., A. Visser and W. A. M. Hijnen. "Growth of Aeromonos hvdrophiha at Low Concentrations of Substrates Added to Tap Water,** Appi Environ. Microbiol. 39(6)'1198-1204 (1980). 26. Bouwer. E. J.. and P. L. McCarty. "BioOlm Degradation of Trace Chlori nated Organics." paper presented at the Annual Conference of the Environ mental Engineering Division, American Society of Civil Engineers, Atlanta, GA. July 9, 1981. 27. Weber. W. J.. Jr. "Integrated Biological and Physico-chemical Treatment for Reclamation of Wastewater," Ind. Water Eng. I4(7):20 (1977). 28. Ying. W.. and w. j. Weber, Jr. "Biophysiochemical Adsorption Model Systems for Wastewater Treatment." J. Water Poll. Control Fed. 31:2661 (1979). 29. Khan, K. A., M. T. Suidan and W. H. Cross. "Role of Surface Active Media in Anaerobic Filters,"./. Environ. Eng. Div., ASCE l08(E2):269-283 (1982). 30. Suidan, M. T,, W. A. Crow, M. Fong and J, W. Calvert. "Anaerobic Carbon Filter for Degradation of Phenols," J. Environ. Eng, Div., ASCE I07(E3); 363-379 (1981). 31. Li, A. Y. L. and F. A. DiGiano. The Availability of Sorbed Substrate for Microbial Degradation on Granular Activated Carbon," paper presented at the Annual Conference of the Water Pollution Control Federation. Las Vegas, NV, September 28-October 3. 1980, 32. Chudyk, W. A. "The Removal of Low Levels of Phenol by Activated Carbon in the Presence of Biological Activity," PhD Dissertation, University of Illinois at Urbana-Champaign. Urbana, 1L (1980). 33. Rittmann, B. E. "A Unified Model of the Performance of Biofilm Reactors." Biotechnoi. Bioeng. (submitted). *4 Roberts. P. V.. P. L. McCarty. M. Reinhard and J. Schreiner. "Organic Contaminant Behavior During Groundwater Recharge." J, Water Poll. Control Fed. 32(1): 161 (1980). 33. Reinhard, M.. C. J. Dolce. P. L. McCarty and D. G. Argo. "Trace Organics Removal by Advanced Waste Treatment." J. Environ. Eng. Div., ASCE I05(E4):673 (1979). 36. Bellar. T. A., J. J. Lichtenberg and R. C. Kroner. "The Occurrence of Organohaljdes in Chlorinated Drinking Watpr."./. Am. Water Works Assoc. 66(12);703 (1974). 37. Baird, R.. M. Selna. J. Haskins and D. Chappelle. "Analysis of Selected Trace Organics in Advanced Wastewater Treatment Systems, Water Ret. !3(6):493 (1979). 38. Bunch, R. L.. . F. Barth and M, B. Ettinger. "Organic Materials in Secondary Effluents," J. Water Poll. Control Fed. 33(2): 122 (1961). 39. Kahn. L.. and C Wayman, "Amino Acids in Raw Sewage and Sewage Effluents," J. Water Poll Control Fed. 36(II):I368 (1964). 40. Subrahmanyam. P. V. R,, C. Amandeswara Sastry, A. V. S- Piabhakarn Rao and S. C. Pillai. "Amino Acids in Sewage Sludge," J. Water Poll. Control Fed 32(4):J44 (I960).
HONS 221904
TRACE ORGANICS REMOVAL 341
41. Rebhun, M., and J. Manka. "Classification of Organics in Secondary
Effluents,* Environ. Sci. Technol. 5(7):606 (1974).
42. Manka, J., M. Rebhun, A. Msndelbaum and A. Boninger. "Characterisation
of Organics in Secondary Effluents,* Environ. Sd. Teehnoi. 8(I2):I0I7
(1974).
43. Murtagh, J. J.. and R. L. Bunch. "Acidic Components of Sewage Effluents
and River Water," J. Water Poll. Control Fed. 37(3):4I0 (1965).
44 Visanathan. C. V.. B. Meera Bai and S. C. Pillai. "Fatty Matter in Aerobic
and Anaerobic Sewage,* / Water Poll. Control Fed. 34:189 (1962).
45. Mueller, H. F., T. E. Larson and W. J. Lennar. "Chromatographic Identifica
tion and Determination of Organic Acids in Water," Anal. Chem. 30(0:41-44
(l8).
46. DeWalle. F. B,, and E. S. K, Chian. "Removal of Organic Matter by
Activated Carbon Columns," J. Environ. Eng. Div.. ASCE 100 (EE5):
1089-1104 (1974).
47. Rutmann, B. E., and P. L, McCarty. "Substrate Flux into Biofilms of any
Thickness." J. Environ. Eng. Div..'ASCE l07(EE4):83l-849 (1981).
48. McDougall, W. J., R. A, Fusco and R. D. O'Brien. "Containment and
Treatment of Love Canal Landfill Leachate," J. Water Poll. Control Fed.
52(I2):29I4-I924 (1980).
`
49. Young, J. C.. and P. L. McCarty. "The Anaerobic Filter for Waste
Treatment." J. Water Poll, Control Fed. 4J:RJ6 (1969),
50. Matsumura, F.. and H. J. Benezet. "Microbial Degradation of Insecticides,"
in Pettidde Microbiology (New York: Academic Press, Ine., 1978), pp.
623-667.
51. Esaac, E. G.. and F. Matsumura. "Metabolism of Insecticides by Reductive
Systems," Pharmacol. Thar. 9:1-26 (1980).
52. Hill. D. W,, and P, L, McCarty. "Anaerobic Degradation of Chlorinated
Hydrocarbon Pesticides," J. Water Poll. Control Fed. 39:1259 (1967).
53. Jagnow, G,, K. Haider and P.-C. Ellwardt, "Anaerobic Dechlorination and
Degradation of Hexachlorocyelohexane Isomen by Anaerobic and Faculta
tively Anaerobic Bacteria," Arch. Microbiol. 115:285 (1977).
54. Healy, J. B.. Jr., and L. Y. Young. "Anaerobic Degradation of Aromatic
Compounds to Methane," Appl. Environ, Microbiol. 38(l):84 (1979).
55. DeWalle. F. B,, and E. S. It. Chian. "Kinetics of Substrate Removal in a
Completely Mixed Anaerobic Filter," Blotechnol. Sioeng. 18(9): 1275 (1976).
56. McCarty, P. L. "Anaerobic Waste Treatment Fundamentals--Part 111,"
Public Workt 95(1 l):9l (1964).
57. Parkin. G. F.. R. E. Speeees and C. H. J. Yang. "A Comparison of the
Response of Metbanogens to Toxicants: Anaerobic Filter versus Suspended
Growth Systems." paper presented at the Workshop on Anaerobic Filter
Technology, Department of Energy. Orlando, FL, January. 1980,
58. Stuckey, D. C., W. F. Owen. P, L. McCarty and G. F. Parkin. "Anaerobic
Toxicity Evaluation by Batch and Semi-continuous Assays," J. Water Poll.
Control Fed. 52<4):720-729 (1980).
59. Murphy. K. L., and R. W. Wilson. "Pilot Plant Studies of Rotating
Biological Contactors Treating Municipal Wastewater," Environmental
Protection Service. Environment Canada. Ottawa, Ontario: (1980).
60. Poon. C. P. C. Y.-L. Chao and W. J. Mikucki, "Factors Controlling
Rotating Biological Contactor Performance," J. Water Poll. Control Fed.
51:601 (1979).
HONS 221905
CHAPTER 22
PEROXIDASE FOR REMOVAL OF HAZARDOUS AROMATICS FROM
INDUSTRIAL WASTEWATERS
Btrbirt N, Albtrtl and Alexander M. Kilbano, Laboratory of Applied Biochemistry Department of Nutrition and Food Science Massachusetts Institute of Technology Cambridge, Massachusetts 02139
Most phenols and aromatic amines are toxic, and many are known or suspected human carcinogens [1-4]. They are inherent in the wastewaters of a variety of industries, including coal conversion, petroleum refining, resins, plastics, textiles, dyes, organic chemicals, paving, roofing, iron and steel. For instance, phenol, cresols and xylenois are produced by high* temperature carbonization of coal, a process that will increase in impor tance as alternative' supplies of fossil fuels diminish.
There are a number of methods currently being used to remove these types of pollutants from wastewaters: microbial degradation, adsorption onto activated carbon, chemical oxidation, solvent extraction, membrane processes and irradiation [2,5-7], Unfortunately, these methods, despite their usefulness, have some serious drawbacks, such as high cost, low efficiency, incompleteness of purification and formation of hazardous by products [7], Therefore, new approaches to the problem of wastewater treatment are necessary.
We have proposed the use of the enzyme horseradish peroxidase to treat wastewaters containing phenols and aromatic amines [8.9], Our method is based on the enzyme's ability to catalyze, with hydrogen peroxide, the oxidation of a variety of phenols and aromatic amines
349
HOMS 221906
35* BIOLOGICAL DETOXICATION
[10,11], thus generating the corresponding phenolic and aromatic amine free radicals [12].
These free radicals diffuse from the active center of the enzyme into solution [13] where they can polymerize to polyaromatic products [10-12], These high-molecular-weight polymers (see Figure 1 as an example), unlike their monomeric precursors, are water-insoluble and can be separated with relative ease by filtration or sedimentation.
We have tested this approach on more than 40 phenols and aromatic amines [8.9]. In most cases, on addition of horseradish peroxidase and HjOj, a solution containing the pollutant immediately becomes colored, followed by gradual separation of a precipitate. To quantify the degree of enzymatic water purification, we use the parameter "removal efficiency" [11,14], which is defined as the percentage of chemical removed from solution under given conditions.
Table I shows the removal efficiencies for some of the phenols and aromatic amines we tested. While many of the removal efficiencies are very high (> 99%), some are significantly lower. Moreover, certain phenols and aromatic amines (e.g., nitrophenols) cannot be precipitated enzymatically. Fortunately, we have discovered an effect that helps to eliminate these problems.
If easy-to-remove pollutants are mixed with hard-to-remove ones, the former aid in the precipitation of the latter. Apparently, peroxidase oxidation of some compounds, such as phenol and aniline, yields products of relatively low molecular weight. These products are appre ciably soluble in water, and therefore the pollutants have low removal efficiencies. However, if the same pollutants are mixed with compounds such as benzidine or 1-naphthol. which polymerize to high-molecularweight products (and have high removal efficiencies), the free radicals from both types of pollutants react with each other to form highmolecular-weight mixed polymers that precipitate readily. This can be
Figure 1. Structure of aniline black, the major product of pcroxidasc-caialvrcd oxidation of aniline *mh H.O; [10],
HONS 221907
PEROXIDASE FOR HAZARDOUS AROMATICS REMOVAL 351
Table I. Removal of Aromatle Amines and Phenols from Water by Horseradish Ptroaidase and H]Oj*
Pollutant
Benzidine
3,3-Dimethoxybensidine
I.J'-Diaminobeniidina
3.3'*Dichtorooeiuidine
3.3-Dtmeihylbcnudinc
1 .Naphthyls mine
2-Naphthylamine
J-Nitre* 1 -naphthylami ne
N, Af-Dimethyl naphthylaminc
Phenol
2-Methoxyphenol
3-Meihoxyphenol
4-Mcthoxyphcnol
2-Methylphenol
3-Methylphenol
4-Methylphenol
2-Qtlorophcnol
3-Chlorophcnot
4-Chlorophenol
2.3'Dimethylphenol
2.6-Dimcibylphcnol
Aniline
.
S-Chloroanilinc
4-Bromoaniiine
4-Ruoroaniline
1,3*Dia minophenot
Diphenvlamtne
1 -Napnthoi
2-Nitroto* 1 .naphthol
i-Phenylphenot
8- H yd roxyquinotinc
Removal Efficiency*
<%>
99 94 99.9 99 6 99.9 99.6 99.7* 91.3* 99.6* 93.2* 85.3* 98.0* 98.6* 89.1' 86.2* 95.3* 85.0* 99.1' 66.9' 98.7* 99.7* I2J* 72.9' 62.5* 84 J* 16 4r 98.6' 80.5r 99 6* 91.9* 99.9* 99*'
Reference
8 8 8 8 8 8 1 8 This work 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 This work 9 9 9 9
' Conditions; I00>ffig/1 aqueous telutiM of a pHanoi or an aromatic amine: 3-hr treatment at room temperature: pH 5.5: 100 units/1 peroxidase. I mM HjOj (unleu othcrwiie indicated).
`Aromatic amina and pbenoli were determined uatn| the ipcctfic assays by Butt and ' 5 m M HjO> 1000 uniu/l peroaidaie. * I mM HjO}. 1000 ttniti/l peroxidase. pH 4.0, `The tame a* in footnote d. but at pH 5.5. ( The ume ai in footnote d, but at pH 7.0. f It should be pointed out that treatment wuh either peroaidaie or H^alone results in no precipitation and no removal of the chemicals from water under the conditions used.
MOMS 221906
M2 BIOLOGICAL DETOXICATION
illustrated by our finding [9] that, whereas the enzymatic removal efficiency for phenol is 74.6%, in the presence of 8>hydroxyquinoline, benzidine and 3,3>dimethoxybenzidine, the removal efficiency for phenol increases to 99.8, 99.5 and 99.7% respectively.
In fact, we found that this phenomenon could even be extended to the removal of nonphenolics and nonaromatic amines, which normally are not substrates for peroxidase. For instance, naphthalene does not react with peroxidase and H:02 at all. However, in the presence of 100 mg/1 of 2,3-dimethylphenol, more than 60% of the naphthalene precipitates, The results are even more spectacular with azobenzene, a common inter* mediate in the chemical industry and a suspected carcinogen [4], Azo benzene does not react with horseradish peroxidase and H-O?. However, in the presence of 2.7-naphthalenediol and l-naphthol. 99.9 and 99.3% of azobenzene, respectively, can be precipitated on peroxidase treatment (20 mg/1 azobenzene. 100 mg/1 naphthalenediol or naphtho), 4 m.W HjOj, 300 units/1 peroxidase, pH 4,0, 48-hr treatment).
The discovery of the enhanced enzymatic removal of poorly or nonremovable compounds in mixtures of pollutants has an important practical implication. Real industrial wastewaters always contain many different pollutants. Hence, even if only a few of them are easily precipitated by peroxidase, they will facilitate the removal of the others by the enzyme and hydrogen peroxide. The significance of this is documented by our experiments with wastewater from a chemical plant.
TREATMENT WITH A CRUDE ENZYME PREPARATION AND OTHER PEROXIDASES
Since our enzymatic treatment is designed to have a practical applica tion, it is important to minimize the eost. In all of the experiments described above, a partially purified horseradish peroxidase obtained from a commercial supplier (Type 11. Sigma Chemical Co., St. Louis, Missouri) was used. However, we also examined the possibility of using a crude enzyme preparation made from horseradish roots bought at a local supermarket. The roots were minced in a blender, suspended in water, stirred and pressed through cheesecloth. The juice was used as a peroxidase source and its enzymatic concentration determined using the standard guaiacol assay [17],
Table II compares the removal efficiencies of several different phenols precipitated by the crude enzyme preparation and the commercial
HONS 221909
PEROXIDASE FOR HAZARDOUS AROMATICS REMOVAL 31}
Table II. Rrtnoval of Phenol* from Water by Purified and Crude Ptroiidwi1
Removal Efficiency* <%1
Phenol
Sl|ma Enzyme
Crude Enzyme
pH
Phenol 3-Methyiphtnol 4-Methvlphenol 2-Qilorophmo) 2.3-Dimcthylphcnol l-Niphthol 2-Niiroio-l-Raphihot t-Hvd roxyqumoline
17 6 15.3 91.5 99.7
996 97,4 96.0 999
19.1 99.6 9J.6 99.7 99J 99.6 9SjO 99.7
35 40 5.5 7.0 4.0 4.0 4.0 7.0
'Condinoni: I00-*n|/l phenol*; tOOO unm/l peroxidate; 2.5 mAf HjO], 21 -hr treatment at room temperature. 'The phenols were trnyed by Ihe method of Emerson [16] (except for 4-meihylphenol, which was uuyctl in accordance with Arnow [II] as'described by Klibanov ci at. [9]).
peroxidase. In ail cases, the results were comparable, demonstrating that the efficiency of this process does not depend on the purity of the enzyme.
We also studied whether peroxidases from sources other than the horseradish root can be used to precipitate phenols and aromatic amines. We examined two commercially available peroxidases (from Sigma), lactoperoxidase from cow's milk and chloroperoxidase from Caldariomj'ces fumago. Treatment by lactoperoxidase and HyOj (800 units/ml enzyme. 2 mmol HjOj, pH 5.5, 24 hr) of 100 mg/1 benzidine, l-naphthylamine, phenol, aniline, 2-methoxyphenol, 1-naphthol, 4-phenylphenol. 3-methylphenol and 2-chlorophenol resulted in removal efficiencies of 90.8 , 35.1, 0, 0, 31.6, 32.0, 38J, 15.4, 13.7%. respectively. The only compound from the above list that can be precipitated enzymatically by chloroperoxidase is benzidine. Therefore, it appears that, although lactoperoxidase and chloroperoxidase are capable of precipitating certain phenols and aromatic amines, the efficiency of their removal is too low to be of practical value. However, since peroxidases are ubiquitous in microorganisms and plants, it seems likely that a bacterial peroxidase may be found that has a very broad substrate specificity similar to that of the horseradish enzyme. Such a peroxidase potentially would be even less expensive than horseradish (see cost analysis below) and be available in virtually unlimited quantities. The search for such an enzyme is currently underway in our laboratory.
HONS 221910
354 BIOLOGICAL DETOXICATION
TREATMENT OF WASTEWATER FROM A CHEMICAL PLANT
To demonstrate the practicability of our method, we used it to treat "real" aqueous effluent obtained from a chemical plant that produces triaryl phosphates (used as flame retardants). The waste sample contained more than 150 different chemicals, including various phenols, cresols, xylenols, isopropylphenol, /m-butylphenol and some nonphenolic com pounds such as triaryl phosphates and inorganic phosphate. The total phenol concentration was 105 mg/1.
Usually this chemical plant treats its water by a two-step process. First, the water is subjected to bacterial degradation, which takes several days and reduces the phenol content by 85-90%. Then, the remaining phenols are removed by adsorption onto activated carbon. The initial step, bacterial treatment, is earned out in open ponds. Since bacteria do not degrade phenols at low temperatures, it is impossible to use such a method during the winter. For this reason, we carried out our treatment of the industrial sample in cold and room-temperature environments, Also from a practical standpoint, it was desirable to work in a pH range of 6-8, because lower pH tends to cause the corrosion of steel columns with activated carbon and other metal containers.
One liter of the wastewater was adjusted to pH 7 and put in a refrigerator. Then, 100 units of peroxidase and 2.5 mmol of HjOi were added to the cold solution. After 40 hr In the refrigerator, the system was assayed for phenols [9]. As a result of our treatment, the phenol concentration decreased from 105 to 3.7 ppm, equivalent to a removal efficiency of 96.5%. Even at 25 units/1 peroxidase and 2 mmol H;Oj, the removal efficiency was approximately 85-90%. The crude peroxidase described above was as effective as the purified enzyme, and treatment at 4C and room temperature yield about the same removal efficiency.
ECONOMIC CONSIDERATIONS
We have attempted to assess the economic feasibility of our method. A precise analysis is not possible at the present time, but a rough estimation can be made. The current wholesale price for horseradish is about 35*/lb [19], and one pound contains about 15,000 units of peroxidase [20]. Treatment of 1000 liters of water (at 25 units/1 peroxidase) will cost 58*. The current price for HjO; is 21*/ lb of 35% solution. Treatment of 1000 liters containing 105 ppm phenols (at 2 mmol H1O2) will cost 11*. Therefore, the total cost of materials for the enzymatic treatment of 1000
HONS 221911
PEROXIDASE FOR HAZARDOUS AROMATICS REMOVAL 355
liters of water is 69*. It is Interesting to note that since the growth productivity of horseradishes is about 8000 lb/ac (1 harvest/yr) [21] the area needed to provide enough peroxidase to treat 1000 liters of wastewater is 0.84 m3.
For comparison, we also examined the chemical cost of the FMC process [22], an existing, commercially available method that uses H202 and an iron catalyst to remove phenol. This treatment oxidizes phenol to CO] and H20. However, it cannot be used with most substituted phenols nor with aromatic amines. Still it is interesting to estimate its cost as we did with our method. Since HjOj and Fe3* completely oxidize phenol, a 14-fold molar excess of H2Oj is required [22]. To treat 1000 liters of water containing 105 ppm phenol, approximately 4 lb of 35% HjOj is needed at a cost of 84*. Therefore, even without the cost of Fe3*, the price of materials for our enzymatic treatment is comparable with that of the FMC process.
CONCLUSION
We have demonstrated that treatment of wastewaters with horseradish peroxidase and H2O] causes the precipitation of phenols, anilines and some other organics. Our preliminary cost analysis indicates that this new enzymatic approach to water detoxication may be economically feasible and cost-competitive with conventional methods. (One should also note that the precipitate formed as a result of enzymatic polymerization of pollutants can, in principle, be burned and the energy obtained can be used for heating.) It is hoped that as industry continues to tackle the ever growing problem of wastewater treatment, the enzymatic process de scribed in this work will be seen as a feasible and attractive alternative.
ACKNOWLEDGMENT
This work was supported by a grant from the U.S. Environmental Protection Agency.
REFERENCES
1. Searle, C.E.. Ed. Chemical Carcinogens (Washington, DC' American Chemical Society, 1976).
HONS 221912
35* BIOLOGICAL DETOXICATION
2. Slein, M.W. and E.B. Sansone. Degradation ofChemical Carcinogens (New York: D. Van Nostrand Reinhold Company, 1980),
3. Fiihbein, L. Potential Industrial Carcinogens and Mutagens (Amsterdam: Elsevier, 1979).
4. Chem. Eng, News (August 25, 1980), p, 23. ! Fair, G.M., and J.C. Geyer. Water Supply and Waste Water Disposal (fit*
York: John Wiley 4 Sons, Inc, 1965). 6. Sittig, M. How to Remove Pollutants from Air end Water (Put P.idge, NJ;
Noyes Data Corporation, 1977). 7. Cleaning Our Environment--A Chemical Perspective, 2nd ed. (Washington,
DC' American Chemical Society, 1978), Chapter 5. 8. Klibanov, A.M., and E.D. Morris. Enzyme Microbiol TeehnoL 3:119 (1981). 9. Klibanov, A.M., B.N. Alberti, E.D. Morris and L.M. Felshin. /. Appl.
Biodiem. 2:414 (1980). 10. Saunders, B.C., A.G. Holmes-Siedle and B.P. Stark. Peroxidase (London:
Butterwonhs, 1964),
11. Barman, T.E. Enzyme Handbook, Vol I (New York: Springer-Verlag, 1969), p. 234.
12. Walsh, C Enzymatic Reaction Mechanisms (San Francisco: W.H. Freeman 4 Company Publishers, 1979), Chapter 15.
13. Yamazaki, 1., H.S. Mason and L. Piette. 7. Mol Chem. 235:2444 (1960). 14. Lanouette, K. H. Chem. Eng. 84(22)^9 (1977). 15. Butt, L. T-, and N. Strafford. J, Appl Chem. 6:525 (1956). 16. Emerson, E. J. Org. Chem. 8:417 (1943). 17. Potter, J. In; Methods of Enzymatic Analysis Vol 2, H. U. Bergmeyer, Ed.
(New York: Academic Press, Inc. 1974), p. 615. 18. Amow, LE/ Mol Chem. 118:531 (1937). 19. Foumie, R. East St. Louis, MO., Personal communication. 20. Braun, Sigma Chemical Company, St. Louis, MO. Personal communication. 21. Rickets, J. W. -Horseradish," Factsheel AGDEX 251 13, 102. Ministry of
Agriculture and Food, Ontario, (1972). 22. -Industrial Waste Treatment with Hydrogen Peroxide,** FMC Corporation,
Philadelphia, PA.
HONS 221913
Jot-*
INDEX
acetonitrile oxidation 230 activated carbon biofllm tupport 333 Acurex process 137.119 air emission from TCDD destruction
286.290 alcohols, PCB extraction 219 alkyl chloride decomposition 48 ambient air monitoring 290 amines, enzymatic degradation 349 amines, products of oxidation 350 anaeroble biodegradation 341
inhibition 342 pH effect 343 anaerobic filler 342 anion radicals 204 aprotic solvent 201 comparison 209,208 Arodor 186.201 Aslcarel 192,202 autoignition temperature 99,102 auxiliary fuel 62
batch recycle 284 benzophenone, electron carrier in PCB
treatment 202.208 bimoiecular reactions 43 biocides 310 biodegradation of industrial chemicals
326 biofllm 326
nomiesdy-state reactor 338 reactors 328.333 support media 333 biological wastewater treatment 37
biphenyl, electron carrier in PCB treat* ment 204,209
boilers, criteria for PCB 135 boilers, destruction of PCB 128,133,
135,136 bond energy 48.65 bond fission 235 burning velocity 77,82,83,86,87
inhibition 84 measurement 81
carbon adsorption 21,38 carbon monoxide monitoring 106 catabolism repression 311 catalysed wet oxidation 276
chemistry 229 radicals 229 cement kilns for PCB 133,134,136 chemical treatment 8.22 chlorinated dibenzodioxin 135 accidents 248 analysis 156-163.258 analytical methods 154,155 formation 253,254 from transformer fire 257 in ash 258 incinera bilily 58 in environment 259 in pesticides 252 instrumentation 163-165 isomer content in suck gas 175,
179,180 isomers 244 sources 250
357
HONS 221914
391 DETOXICATION OF HAZARDOUS WASTES
standards 165 structure 144 toxicity 247 Set also teirachlorodibenzodioxtn chlorinated dibenzofuran 135,240 accidents 250 analysis 156-163.258 ' analytical methods 154,155 formation 256 from transformer fire 257 in ash 251 incinerabilily 58 instrumentation 163-165 isomer content in stack gas 175,
179,180 isomers 244 physical properties 245 standards 165
structure 144 chlorinated solvents, biodegradation
326 chlorinated solvents in groundwater
326 chlorination 8 chlorine in combustion 62,66 colonization potential 308 combustion
catalytic 77 chemistry 42,72 mechanism 74 products 64 research 61 vwo-stage 73 cometabolism 310,329 computer model of plasma arc 191 containment of microorganisms 320 contingency plan 296 cool flames 73 cooperation, industry/government
265 cyanide destruction 8
DDT oxidation 230 dechlorination 277.280
anaerobic 341 dehalogenation, enzymatic
303
destruction removal efficiency 46.97, 134
detoxication, definition 3 dewatering 23 dichloropropionic acid 305 diglyme, a protic solvent inPCB treat
ment 202.212.208 diphenyl hydrazine oxidation 230 distillation .24 drinking water quality 324 drying 23
economies of enzyme degradation 354
electron carrier 201 comparison 209,208
emulsion breaking 22 energy recovery 29 enforcement of PCB regulations 126 engineering controls 285 Ensco incinerator 118,147 Environmental Defense Fund 125 environmental effects, microbial
degradation 317 equilibrium in combustion 70 equivalence ratio 63,82,83 euirophs 309 excess air 52,67,12
flame contact 98.57 flame inhibition 72,84 flocculation 34 flue gas cleaning 28 Franklin Institute process free radicsls 49,67,72.88
120,137
gas chromatography/mass spectrom
etry in analysis of dioxins 159 in analysis of suck effluents 158 instrumentation 163 General Electric process 137.120 genetic engineering barriers 306J18 genetic engineering, microbial ecology
307 genenc manipulations 303
HONS 221915
INDEX 359
Goodyear process 137 groundwater contamination 324,326 groundwater quality 324
interfaces, microbial degradation 311 isopropyl alcohol in TCDD destruc
tion 280
hazardous waste cntena 110 definition xiv delisting 110
health effects 294 microbial degradation 317
heat of combustion 57,64,99 heat of formation 45 heat recovery 29 heavy metals treatment 34 Hanry's law constant 21 horseradish peroxidase 350
commercial 353 crude 352 hydrogen chloride removal 95,101 hydrogen donors 280 hydrogen in dehalogenation 216 hydrogen peroxide 10449,355 hydrogen radicals 49 hydroxyl radicals 49 raw of reaction 53
incinerability 5546 research needs 57
incineration 25 air feed rate 106 criteria for PCB 134 gases 12 monitoring 105 operation 105 solvent 11 warn feed rate 105 Ste abo combustion
incinerator for PCB 133,136 performance standards 30,94,95 risk assessment 178 schematic 146,147
industrial hygiene 292 industrial wastes, examples 6,15,16
Kepone 216 kinetics of combustion 72
leachate 339 Love Canal 340
leaching tests 114 legal involvement 263 light flux 222 lower hazard limit 325
medical considerations 294 methanogenesis 341 microbial degradation, increased
activity 316 microbial degradation of organic
compounds 315 microorganisms, commercial 307 microorganisms, operating conditions
319 mineralization 302 mineral oil in transformers 202 mineral oil, PCB removal 129 miniplani operation 273 model of bioftlm kinetics 326 model, photochemical 235.237 modified EPA Method 5 150 mutagenesis, site-specific 305 muution 305
naphthalene, electron carrier in PCB treatment 202408412
NEPACCO 261.269 NEPACCO waste
analysis 272 composition 274 solvent extraction 277 neutralization 10 nitrogen oxides 68
obstacles to detoxication 262 oil reprocessing 11,24
HONS 221916
3*6 DETOXICATION OF HAZARDOUS WASTES
oligotrophs 309,329 optical density 213 oxidation 8,10
rates 69 oxygen transfer 229 ozonation 140
paniculate removal 28,95,104 pentachlorophenol oxidation 230 personnel protection 270 phase-transfer in PCB destruction
120 phenols, enzymatic degradation 349 phenols, products of oxidation 350 phosgene combustion 66 photodecomposition in environment
234 photolysis 235,237
experimental 273 operation 285 products 238 reactor design 284 photorcduction 281 pilot-plant l)V reduction 221 plasma, definition 189 plasma torch 119,191 plasmid compatibility 318 fusion 317 TOL 305JI6JI9 transfer 306,316 polychlorinated biphenyl adsorption 140 alternative treatment 127,132 analysis 193,216 analysis in stack effluents 160,163 catalyzed process for destruction
210 chemical treatment 137,140 combustion technologies 133,136 content in suck effluents 181 dechlorination 137 destruction by plasma 193 destruction by sodium 204 destruction in boilers 128,133,135,
136
exemptions to regulation 122 export 124 extraction 140,219 extraction from soil 218 generic treatment 201,205 m Canada 186,188 in stack effluents 178,181 incineration 119 incineration criteria 134 incinerators 128.133.136 in environment 186,233 meul treatment 137 oxidation 231 photochemical decomposition in oil
223 photolysis products 238 products of chemical treatment
212^13 production of UV reduction 219,
224
pyrolysis 256 radical chain reaction 206 rate of photoreaction 220,221.222 regulation 122,126,131,144 regulatory cutoff 126 removal from mineral oil 129 siting of treatment facilities 133 soil 216 structure 144 summary of treatments 119 toxicology 167 transport 234 treatment requirements 204 treatment with aprotic solvents
202,212.218 use 186 use near food or feed 124 water quality standard 122
wet air oxidation 139 precipitation 34 pretreatment 8,18,36 principal organic hazardous
constituent (POHC) 55,95 process control in solidification 111 products of combustion 133,135,145 products of PCB treatment 212.213 pyrolysis 65.74
HOMS 221917
INDEX MI
rate contents 78 reaction mechanism, incineration 42 reaction paths, PCB reaction with
anion radicals 205 reaction products from TCDD 280 recovery 8,18,23,29
and reuse xiii residence time 46,47 Resource Recovery and Conservation
Act 93 Appendix Vlll Chemicals 97 risk assessment 178 Rollins incinerator 119,146 rotary kiln 26
safety 270.295 of microbial degradation 317
sampling process 296 sampling of suck effluents 150,152,
171 scaleup -280
of PCB destruction 211 secondary combustion 26 secondary utilization 329 Sherman mechanism 206 siting of PCB treatment facilities 133 siting of waste treatment facilities 114 sludge processing 22 sooium meul 201,212 soil deeonumination 120 soil PCB 218 solidification agents 112 solidified waste uses 113 solvent extraction 21,277 soot formation 86
mechanism 19 stability, thermal oxidation 46,55,36,
99 stabilization 30,32 stabilized waste characteristics 33 stack effluents
chlorinated dioxin content 179,180 chlorinated furan content 179,180 PCB content 178.181 risk of breathing 178 sampling 150
stack effluent samples cleanup 157 extraction 156 liquid chromatography 157
slack monitoring 107 slack samples, accuracy of analysis
153.171 steam stripping 20 stripping 11,20
substrate concentration, minimum 326
substrate, primary 330.338 SunOhio process 119,137
tesrachlorodibenzod ioxin analysis 271 column chromatography 272 combustion product 67 destruction, isopropyl alcohol in 280
formation 253 health 270 in environment 255 in Ensco effluent 169 in Rollins effluent 167 in suck gas effluent 175 in wildlife 255 isomer distribution 171-175 no absorption 283 oxidation 231 rate of decomposition 279 reaction producu 280 safety 270 thermodynamics 45 toxicity 246,247 wastes from destruction 292 St* also chlorinated dibenzodioxin tetrachlorodibenzofuran in Ensco effluent 170 in Rollins effluent 161 isomer distribution 176 tetrahydrofuran, solvent in PCB treat*
mem 204.208 thermal oxidation 99
subility 46,55,56.99 thermodynamics 44
of combustion 62
MONS 221918
M2 DETOXICATION OF HAZARDOUS WASTES
threshold effect 331 toxicity xiv
definition 302 Toxic Subitancei Control Act (TSCA)
122,132.203
transformer fluids 119 treatment
of hazardous waste, definition 109 onsite 113 regional 113 trial bum 96 trichlorobenzene destruction by
plasma 196 trichiorophenol, dioxin formation
273 turbulent flow 284 turbulent mixing 98
ultraviolet light 140.216 decomposition 277 lamps 283 interferences 283 reactors 216
unimoiecular decomposition 53
42,47,
waste heat boiler 29 waste prcireatment, in solidification
112 waste segregation, in solidification
112 waste treatment, public acceptance
141 wastes from TCDD destruction 292 wastewater 336
industrial 334 wastewater treatment 34
biological 337 enzymatic 334 water activity 309 wet oxidation 139 catalyzed 227 chemistry 228 radicals in 228
o-xylene oxidation 230
yusho 188,203
HONS 221919