Document nk5BwJm6V5kn35zx73N6VorN8
D. H. Ferguson L. G. 6a1ner
Asbestos Survey * Patchers
Vrdtzd
CASTIftN 8TIII. DIYWOW * March 18, 1980 f"* N. R. Stromness, Superintendent
Environmental 8 Health Services
On March 11, 1980, an asbestos survey mss conducted on #8 Battery. The purpose of the survey ms to evaluate employee exposures to asbestos fiber while using asbestos rope to pack sllpjolnts.
Criteria:
OSHA limits an employee exposure to asbestos dust to two fibers longer than five micrometers per cubic centimeter of air based on an eight hour time weighted average exposure.
Conclusions:
The results of the survey (Table 1) Indicate time weighted average exposure of 0.08, 0.05, and 0.03 flbers/ce of air for the three employees monitored. These exposures are within the permissible exposure limit of
i fibers/cc as established by OSHA.
Recownendatlons:
1. During the survey. It had been noted that compressed air was used to blow out sllpjolnts. This practice should be discontinued Imnedlately.
2. The Safe Job Procedure (P-31) January 29, 1980, should be followed.
PRB/cay Attachments
USEI000085
(
ASBESTOS SURVEY ClAIRTON WORKS
3/11/BO TABLE I
; Activity
Puratlon/mlnutes
(Replacement of 4 standpipes on 18 Battery)
Patcher Pavlack
Chipped out old asbestos around the standpipe, cleared out old asbestos with compressed air. After the stand* pipe was removed, used compressed air to clear opening of debris. Also chiseled carbon from Inside of opening. Sprayed In repair cement. After new pipe was put In place, he packed the wet asbestos rope In sllpjolnt and sealed with mortar.
138
Asbestos Exposure Flbers/cc
.16
Continued as above on other standpipes as they were removed. Alternated jobs with other Patcher.
45
.33
Time Weighted Average exposure (TVM) Is .08 flbers/cc air
Patcher - Day
Chipped out old asbestos around the stand* pipe. After the standpipe was removed, used compressed air to clear opening of debris. Also chiseled carbon from Inside of opening before spraying In repair mortar. After new pipe was put In place, he packed wet asbestos rope In the sllpjolnt A sealed with mortar
Continued as above on other standpipes as they were removed. Alternated jobs with other Patcher.
135 48
.11
.23
i
Time Weighted Average exposure (TWA) Is .05 flbers/cc air
USEI000086
3/11/80 ASBESTOS SURVEY (continued)
Activity
(Replacement of 4 stendpipcs on f #8 Bettery)
Puratloir/mlnutes
Asbestos Exposure Flbers/cc
Petcher - Welker
Worked on wilkway ebove battery aaln. Chipped out asbestos around upper slip*
joint. After new pipe ms put In place, packed sllpjolnt with Mt asbestos rope
and sealed with sorter.
Continued as above with packing new slip*
joints as the pipes Mrs replaced.
129 55
.06 .14
Time Weighted Average exposure (TWA) Is .03 flbers/cc air
USEI000087