Document nk44nwrNOQVzymYYGz4jwdbY6
Monsanto industrial chemicals co.
R* H. Munch - S. Second St. - St. Louis
VJCCT
March 9, 1972
cc P. G. Benignus - GO W. R. Richard - GO
M'tfttMCfc
.W. B. Papageorge 'General Offices - B2NK
You have asked for my comments on the latest draft of ANSI
Committee C-107 proposed guidelines for handling askarels in the manufacture of capacitors. They are as follows:
1. The proposed guidelines represent a very great step forward because they show that the capacitor industry
is beginning to understand the problem and is beginning to think about how to try to solve it.
2. The great problem is not what you or I or others connected with production and use of askarels think but whether or not we can secure agreement from environmentalists and government agencies that the guidelines are adequate to protect the public present and future.
3. They will not be convinced unless we supply supporting data. The data needed are:
a) Proof that the lower PCB's do degrade more rapidly than the higher ones.
b) The best possible data on rates of degradation by all mechanisms - photo, bio, oxidative or others.
c) Data on toxicity. d) Data on migration of PCBs through soil.
e) Data showing how much the already accomplished industry actions will reduce PCB input, particularly higher PCB input, to the environment.
4. Were these guidelines approved by the whole committee - including members who represent the government and environmental viewpoint or only by industry representa tives?
5: I am returning parts of the draft with minor errors
which you will want to correct marked.
6. We need a similar document for the transformer industry.
I think that if we supply supporting data and get-a guideline for the transformer industry too, we should be able to win.
db Enel.
& i-l
R. H. Munch
MQNS 098713
Monsanto
....... location,
lUSJICl
w. B. Papageorge - Qeneral Offices, B2NK
March 7, 1972
cc P. 0. Benlgnus - B2SC W. R. Rlohard - T3A
TO :
Dr. R. H. Munch 1760
Attached is a copy of the latest draft of proposed guidelines for handling askarels in the manufacture and use of capacitors. These guidelines have been developed by a working committee under the auspices of ANSI Committee C-107.
I would appreciate any comments you may have to offer.
/bt Attachment
W. B. Papageorge
MOMS 098714
p* ' ^ '*' " b4 U La ti Ik *4
C 0 I.; ? A II Y
JOHN ST83ET, HUDSON f*US, NJW YOUX 1383? . . . A8EA CODE 518. TELEPHONE 747-3341
INDUSTRIAL AND POWER CAPACITOR DEPARTMENT cc; E. L. Raab
March 1, 1972
AN'S I C 107 WORKING GROUP ON CAPACITORS
P. G. Bcnignus, Monsanto Company R. D. McClain, Westing'nouse Electric Corp. A. M. Salazar, NEKA J. F. Xuzela, Sangair.o Electric Company N. R. Clark, Universal Nanufacturing Company W. P, Pajateorge. Monsanto Company E. G. Hammer, McGrav-Edison Power Systems Div. Dr. E. X. Moore, Electric Utilities Co. F. R. Lengefeld, Union Electric Co. A. S. Doty, P. R. Jlallory Co. Inc.' ' K. L. Rollins, Jard, Inc.
Attached is the revised Guideline for capacitors as a result of our February S meeting.
Parts VIII and IX are not included. You have received Part IX in an earlier communication and the only change I anticipate is the deletion of some of the reference chromatograms of pesticides. I will coordinate this with Ed Raab of the Transformer Group since the analytical procedures would probably be common.
I have had our legal people review the " should" versus "shall" question and the writeup is as recommended by our Company attorney.
You will note that the suggested warning label on the last page contains more information than originally thought might be needed. After further discussions within General Electric I am advised thet it is desirable to state the fact that PCB's are involved and to identify the potential hazard (l.e. environmental contamination).
Please let me know by March 15 of either your approval or if you have any changes. Ky next step will be to get together with Ed Raab to review our Guideline writeups.
A. Pozefsky Manager-Engineering
?S att.
tMONS 098715
TABLE OF CONTENTS
I - Introduction
II - Capacitor Grade Askarel
III - Housekeeping
IV - HjO Effluents
V - Vapor
'
VI - Scrap Disposal
VII - Labelling
VIII - Disposal Services
IX - Analytical Procedures
HONS 098716
D R ART
INFORMATION PURPOSES ONLY -- NOT FOR EXTERNAL USE
SECOND PRATT - For ANSI C 107 Review gtrTgbrttarr-^r-Wa-
Guidelines far Handling and Disposal of Capacitor Grade Aakarela
I. INTRODUCTION
Th* environmental effect* of aakarela are under in-depth atudiea by governmental and other agancie*. Aakarals have bean conaldarad aa relatively haraleee materlala to humane baaed on about forty yeara of aafe induetrial usage. There haa bean no known Instance of human Injury when uaad undir the normally accepted conditions of precaution and handling^ In both manufacturing and customer applications.
races of ankarel*are being found In the environment and In fish and blrdlife. Although they have not bean considered aa toxic to humans, the long term genetic and ecological affaets are not yet completely understood. For these reasons care should be taken to contain aakarels and minimise their entry Into the environment.
Thera are two general grades of askarels used by the electrical Industry. The higher chlorinated grades era the more persistent In nature. Because of their non-flammablllty, they are used In transformer* where personnel safety and reliability are of paramount Importance.
Capacitor grads askarel haa a lower degree of chlorination, a higher degree of blodagradabillty, and generally has not bean found in animal Ufa. It la used In capacitors where the extreme degree of nonflammability required In transformers Is of lea* Importance (the largest capacitors use In the order of 2 to / gallons of askarel compared to hundreds of gallons In larger transformers). Capacitor grade askarel Is
MQNS 09871V
Page 2
conposed primarily of the 3-chlorine Isomers of biphenyl. This degree of chlorination ia found to be more stable chemically and electrically in_japacitors than the higher chlorinated fractions, and is most important in getting good capacitor life and reliability.
Although capacitor and transformer grade askarela are both members of the PCB family, they do differ in composition, degree of biodegradability, persistence in nature, electrical stability, chemical stability, and degree of non-flammability (both are recognized as non-flammable).
II. CAPACITOR GRADE ASKAREL
In September of 1971, a new grade of capacitor impregnant, Aroclor 1016, was made available to the Industry. This new grade contains a maximum concentration of 0.4X by weight of the pentachloro and higher chlorinated components, Aroclor 1016 replaces Aroclor 1242 which previously as the major capacitor Impregnant and containad around 7X of the pentachloro and higher fractions (the more persistent in nature). This 0.4X level of the higher chlorinated components should be the maximum concentration acceptable in any capacitor impregnant. Aroclor 1242 and 1234, previously uased as lmpregnants, do not meet this requirement and should no longer be used in capacitors.
Aroclor 1016 hss the same non-flammability rating by UL as Aroclor 1242. Ita typical proptrtles are given in Table I,
III. PLANT HOUSEKEEPING & EMPLOYEE SAFETT . The following procedures and limits are Intended to be minimum requirements to be met by manufacturers and users of capacitors containing polychlorinated biphenyl.
MONS 098718
TABLE X
TYPICAL PROPERTIES OF AROCLOR 1016
Color (APHA)
Condition
Sp. Cr. 9 23/15.5*C
Acidity (mg. KOH/g.)
Moilcur*
Refractive Index 3 25*C
Inorganic (Free) Chlorldea
Pour Point
Dielectric Constant
(1000 Hz 9 100'C)
Resistivity
(300 VDC 0 100*C. 0.1" Gap.)
Hydroloala Stability Teat
(As Chloride*)
Hohaanto Stability Teat
(A* Chloride*)
Distillation Range
(ASTM D-20 corrected)
10Z Dl*tilled by Wt.
90X Dlatilled by Vt.
Pent* and Hexachloro
Blp^bnyla
Sulfate*
Dielectric Strength
0 25*C KV
Fla*h Point *P
.
Fire Point
Corrosion Teat (6 hrs. 9 210*C
with bright A1 foil)
Change In wt. of A1 X
A.C. Color (APHA)
A.C. Condition
A.C. Acidity (mg. KOH/G)
A.C. Inorganic (Free) Chlorldea
Mlae. 9 100'F (SlIS)
Specific Heat 0 25*C
Coefficient of Expanalon
(25-65*C) CC/CC*C
Fixed Chlorine
Power Factor 0 100*C
Typical Value* 60 Hz
1000 Hz
40, max. Clear 1.362-1.372 0.010 max. 35 ppm, max. 1.6215-1.6235 0.05 ppm, max. -14'C or lower 4.70-4.90
500, min.
0.5 ppm., max.
0.4 ppm, max.
323'C min. 356*C max.
0.4Z max. Hone
35 min. 338 min. None to 8.P.
0.0 60, max. Clear 0.010, max. 0.05 ppm, max. 71-81 0.30 0.00068
41.3 + .51
5
HONS 098719
Page 3
Handling, control and dlaposal procedures are given, together with exposure limits
and Indicated antidotes and cleanup procedures.
.
1. Material. Chlorinated biphenyl for use In capacitors should consist of
chlorinated homologous and Isomers of biphenyl with the pentachloro and higher fractions
not exceeding 0.42. Aroclor 1016 Is considered the standard lmpregnant meeting these
requirements.
Solvents include benzene, kerosene, acetone, amyl alcohol,, either, and chloroform.
Typical vapor pressure properties of Aroclor 1016 are
0*C - 0.001 mm 25C 0.006 mm . 150C - 4.3 mm 200*C -29.0 mm
At 25*C and 760 mm Hg pressure, saturated air contains approximately 0.09 mg/liter.
(1 mg/liter - 90. ppm (v/v)) (1 ppm (v/v) - 0.011 mg/liter)
2. Bulk Fluid Shipment, Receiving, and Transfer. Shipment of polychlorinated biphenyl from point of manufacture to point of receiving ahould be done In closed
containers: rail tank cars; truck tanks; marine or barge tanks; or sealed drums. Containers should be labelled as to contents, and carry a precautionary lable against loss of fluid to the open environment. Containers used for transport of askarel ahould not be used for storage or transport of other material without being completely cleaned of all traces of askarel. (Cleaning procedurea must take cognizance of precautions against excessive exposure and of the need for.proper disposal of contaminated cleansing
solvents end materials as set forth in Section VI.) Transfer from shipping container to processing system should be through closed piping or tubing with appropriate valves, pump?, etc. Provision should be made for trapping and disposing of fluids lost by
:* leakage or spills from the transfer system and from the storage containers*
MUMS 090720
Page 4 Drum* to be retired from use should be cleaned before crushing, delivery to scrap daalerB, or other disposal. Contaminated cleaning fluids and materials should be disposed of as indicated In Section VI.
3. General Safety Precautions. Although it is generally accepted that exposure to capacitor grade askarel Is not hazardous, provided simple precautions are taken, exposure should still be avoided and minimized.
(a) Vapors. The odor of askarel Is noticeable well below the maximum air concentrations considered safe. Maximum atmospheric concentration limit (6 hours exposure) shall not exceed one milligram of capacitor grade askarel par cubic meter of air.
Breathing vapor or fumes from heated askarel shall be avoided. Provisions
must be made for adequate ventilation and regulation of manufacturing operations
to avoid open exposure to askarel (especially at 55*C or higher). The gases
produced when askarel Is decomposed by very high temperatures (such as that
of an electric arc) in the presence of air or organic insulating materials
contains a high percentage of hydrogen chloride, and small percentages of
carbon dioxide, carbon monoxide, and ojfrgen. Minute concentrations of this
combination of gases are very unpleasant and Irritating, thus giving ample
warning of their presence. If exposure to high concentrations of askarel Is
necessary under emergency conditions, an approved gas mask or self-contained
breathing apparatus must be worn. Such exposure should be under the surveillance
of other personnel capable of rescue In case of an accident. If the odor of
askarel is detected by the person wearing protective equipment, lie should
Immediately go Into fresh air. All gas masks, respirators and replacement parts
should have Bureau of Mines approval, and be maintained on a regular schedule in
accordance with the manufacturers recommendation.
MUNS 098721
Page 5
(b) Fluid. Unlike insulating- oil, there is virtually no fire hazard in handling askarel. A limited solvent action (similar to that for paint thinner) on the fats and oils of the skin with prolonged contact may lead to drying and chapping of the skin. As with insulating oil, some people are allergic to askarel and continued exposure may result in skin irritation. Both the liquid and vapor are moderately irritating to eye tissue.
Operating procedures should avoid concact with any askarels. Use of eye protection is recommended. The use of porous gloves which can absorb and retain askarels is to be avoided. Barrier creams (e.g. PLY No. 9 Gel by Mllbum Co., Detroit. Mich.) or resistant gloves* should be used If contact la unavoidable. Use of enclosed transfer and handling equipment, processing equipment and mechanical washers reduces direct contact.
Medicinal washes or mild detergents followed by application of cold cream will reduce irritation resulting from askarel contact with an open cut or abrasion.
Safety glasses with side shields or a face shield should be worn when handling
askarels. If eye contact to liquid askarel occurs the eyea should be Irrigated
Immediately with large quantities of running water for fifteen minutes and then
examined by a physician. (A drop of castor oil has been found to reduce
Irritation caused by eye contact).
MONS 09872k
Persons developing a skin irritation or respiratory tract Irritation while working with askarels dould be placed under the supervision of a physician.
Ingestion or swallowing of askarels is not generally regarded aa a problem of
the industry. Askarels are regarded as being moderately toxic if'taken internally,
and could causa irritation of the digestive tract and Internal reactions. Hands
should be washed clean of askarels with warm water and soaJ()before eating, drinking,
smoking or use of Collet facilities after handling.
'f
McCli* tr.
Page 6
4. Manufacturing Housekeeping. Manufacturing equipment and operating procedures must safeguard against lose of askarels tc the environment through proper containment and disposal procedures.
Enclosed systems of sealed piping, properly gasketed Jolnt9, valvea, containers, and processing chambers are to be used for any portion of the operadon where askersl temperatures may exceed 5SC. Enclosure should preferably extend to all other portions of the systom Insofar as practicable.
Containment provisions should be established around all askarel processing areas to assure against Inadvertent loss to sever systems by spillage, leakage, or other uncontrolled conditions or events.
Ventilation of the area and exhaust of pump and systems gases should be controlled to restrain vapor losses to the atmosphere (see Section V).
i Spills of askarel should be removed promptly by uae of absorptive material such as
sawdust, or trapped and removed by pumping or other suitable means. Waste fluids.containing askarel and not suitable for reconditioning or reuse should
be collected (by means of traps, drip pans,trays, etc.) from the various parts of the manufacturing and processing area (including washers or other cleaning devices). Disposal should be by approved incineration or in clean landfill areas in sealed containers, if permitted (see Section VI),
Wiper rags, clothing and other extraneous materials saturated with askarels should be collected within the containment area for properly controlled ln-plantlaundering or dlapcMl (see Disposal of Liquid and Solid Scrap - Section VI). Outside commercial laundering or dry cleaning services should be used only if their disposal procedures are conslatent vlth the gulldelines in Section VI.
i /
MONS 098773
Page 7
5. Dlapoaal of Askarel Uaatea. Methods for disposal of liquids and saturated solids generated by the manufacturing operation should be in accordance with those outlined in Section VI of this Guide, and should Include (but not be limited to) the following:
A. Liquid askarel contaminated by aliphatic materials and other substances such as to make it unsuitable for reclaiming as a dielectric fluid.
B. Liquid askarel from solvent operations or vater/detergent type washers. C. Saturated earth or other absorbent media from filtering operations. D. Saturated sawdust or other absorptive materials from api'lie.. E. Saturated filters from vapor control devices and other filters. F. Saturated wastes (paper, rags, etc.) G. Saturated, spent gasket materials, H. Askarel contaminated vacuum pump oils. I. Askarel contaminated stream jet vacuum system condensates.
6. Miscellaneous Procedures. A. Spills by leakage from sealed, finished capacitors diould be cleaned up promptly by use of absorbent media which should then be removed to containers for that purpose within the containment area, and later disposed of properly. B. Askarel wastes should never be disposed of down effluent drains or sewers. The utmost care must be exercised to prevent accidental loss by these avenues to the environment. C. Capacitors failing test or otherwise designated for disposal must be controlled and handled in accordance with the intent of thf procedures above, finally being disposed of by one of the means outlined in Section VI.
MOMS 098724
Pag* 8
7. References:
A) Monsanto Company, Organic Chemical Dlvlalon: Tech. Bulletin fPL-306, Aroclor Plasticizers (December 1S60).
B) American Conference of Governmental Industrial Hygienist*: Threshold Limit Values for 1964. AMA Arch. Environ. Health 9:545 (1964).
C) Treon, J.F., P.P. Cleveland, J. Cappel, and R.W. Atchley: The Toxicity of the Vapor* of Aroclor 1242 and Aroclor 1254. Amer. Ind. Hyg. Aaaoc. Quart. 17:204 (1956).
D) Elkina, H.B.: The Chemistry of Industrial Toxicology. John Ullsy and Sons, Inc., Nav York (1959).
E) Drinker, C.K., M.P. Warren, and G.A. Bennet: The Problem of Possible - Systemic Effects from Certain Chlorinated Hydrocarbons. J. Ind. Hyg, Toxicol. 19:283 (1937).
F) Drinker, C.K.: Further Observations on the Possible Systemic Toxicity of Certain of the Chlorinated Hydrocarbons. J. Ind. Hyg. Toxicol. 21:155 (1939).
G) Greanburg, L., M.R. Mayers, and A.R. Smith: The Systemic Effects Resulting from Exposure to Certain Chlorinated Hydrocarbons. J. Ind. Hyg. Toxicol. 21:29 (1939).
H) Hygienic Gulda Serias "Chlorodlphenyls" by the American Industrial Hygiene Association, 14125 Prevost, Detroit, Michigan.
IV. CONTROL OF WATER EFFLUENTS
The Industry goal is "zero" concentration of askarel in plant water effluent streams. However, It la recognized that existing drain systems In capacitor manufacturing plants
are probably contaminated as a result of past practices, and askarel traces may continue
show up In effluent streams for some time. However, the level should continue to
decrease with the proper containment of askarel wastes and no further discharges Into
drain systems, Other sections of this Guide provide that no askarel wastes of any
kind ba disposed of In any water affluent streams, and that accidental spills be prevented from getting Into such streams.
MONS 098 725
XT A. Concentration Limits. Th# maximum allowable concentration of askarel la
water should be 200 parta per billion. 0*r"5 24 hour bails* ithe askarel content of all
--- i
` /
plant water affluent atreana shall not exceed five pounds/
B. Monitoring Streams. On a regular bisla not to exceed 3 month Intervals, and on
a more frequent basla If required by the locel plant situation, all effluent atreaaa
should be analyzed to determine compliance with the limits In Fart A. Thla can ba .
dons by taking a "worst" sample during the day, or a 24 hour composite. Tha procedures
for performing the necessary analyaea are contained In Section IX, ANALYSIS OF WATER
AND SEDIMENT FOR POLYCHLORINATED BIPHENYLS (or lte equivalent!
C. Methods for Minimizing Effluent Stream Contamination. The Ideal approach la
to totally Isolate all effluent streams that could be contaminated with askarels during
manufacturing procasaaa and prevent them from being discharged from the plant.
Procedures that could be implemented to this end are aa follows:
. l. Collect askarel bearing atraama and either by gravimetric or centrifugal
separation recycle the water phase for reuse and dispose of the sakarel-rlcb
phase under the-liquid dlapoaal guidelines described elsewhere herein.
2. In all manufacturing areas where askarel spills can occur, connect drains to an Isolated sump where the spills can be accumulated end pumped out for disposal.
3. Carbon adsorption, limestone beds, and solvent extraction are techniques which can be applied to reduce the askarel content from effluent streams. This may be required to meet the limits defined in Fart A above, Thla may be moat appropriate In cleaning up water used in plant processing end recycled, but which ultimately may have to be disposed of. Such dispose]; couU be done through Incineration, but may be more practical by adsorptive purification.
MUNS 0987d6
Page 10
D. Proeadura for Water Sampling. Initially alleffluentjstr earns from the plant ahould be sampled to determine valuea end to identify askarel bearing atreame. Hourly samples of the etreoma should be taken during a typical operating period to Insure the samplas arc representative of the effluent, or a single sample collected continuously over the operating period. The flow rates of the affluent etreoma ehould bs measured whan the samples are taken. The hourly samples from each stream are then composited In proportion to the flow bate of the straam. Analyses of the composite samples are done In accordance with the procedures outlined in Section IX.
The actual aekaral discharge of any effluent nan be computed from the quantitative analysis of Its composite samples and the mean flow rate of the stream.
V. CONTROL OF VAPOR EFFLUENTS
Normal plant ventilation will carry aekaral vapors to the environment. The composition of aekaral In the vapor Is expected to be fca&lee in the lower chlorinated fractlona of MCS 1016 vhlch have the higher vapor pressures (and also have the higher degree of blodegradablllty).
A. Concentration Limits, The cotal plant stack emissions should not exceed
v S pounds per dey.
B. Monitoring. The monitoring of appropriate stack effluents should be done on
a periodic basis not to excead 3-months, and more frequently If required by the local
situation. Test Method 70-6 contained In Section IX, PROCEDURE FOR THE DETERMINATION
OF AIRBORNE POLYCHLORINATED BIPHENYLS (or Its equivalent)
^
.
HONS 098727
Fags 11
C. Othsr Considerations. Largs exposed surface areas of aakarsl_, especially it iriintained at an elevated temperature, will be the major contributor to any concentration of astcarels found In stack 'effluents. Open containers should be enclosed with vapor tight covers to avoid thle.
D. Procedure for Air Sampling. Identify exhaust stacks which may contain
airborne askarel. A composite sample of each stack should be gathered over a typical
24 hour operating period. The sample Is collected by aspirating a known volume of che
exhaust gases through hexane. The askarel, being soluble in hexane., will be collected can be
and a quantitative determinationmade through the use of gae chromatograph/electron
capture techniques ae described In Section IX.
'
'From the quentltetlve determination and with a knowledge of the volumetric flow rate of a given stack, the total weight of eekarel discharge can be computed.
VI. SCRAP DISPOSAL PROCEDURES
The manufacture end use of capacitors Involve processes wherein askarel saturated sollde end liquids containing, or composed entirely of askarel, must be disposed of In s manner consistent with proper concern for the environment. Specific sources of these materials appear throughout this document but may be placed Into threa categorlea s
A. Capacitor units impregnated with Askarel; Production and Field Failures(mechanics or electrical); obsolete Items.
B. Manufacturing process liquid wastes containing askarel. C. Solid waste purposely or accidentally saturated with askarel.
MOMS 09872b
Page 12
PART A DlapoaaX of Capacitor Unite
Scrap capacitor unite can be generated during manufacturing procaaees,
or during field service.
Production rejecta are thoaa capacitors which are rejected after the
impregnation process, in the course of production by the capacitor manufacturer.
They may ba rejected for mechanical or electrical reasons, or because of
obsolescence.
-
Field rejects are those which are rejected, or which for other reasons
arc to be scrapped, after shipment from the plant where they were manufactured.
Pleposal Procaduraa
l. Traduction tojacu
Rejected capacitors are generated in sizeable quantities in capacitor manufacturing plants, and because they represent a concentration of aakarel, it is important that their disposition be made in a manner consistent with proper concern for the environment. Therefore, capacitors should be disposed of only in dry landfill sites which meet all applicable Federal- and State requirements.
Cara should ba exercised to Insure that no loss of liquid will occur during transportation to the disposal site.
Solid incineration of scrap capacitors is a,disposal alternative as such services become available in the future.
1 MOMS 098729
Page 13
2. Plaid Rejects
__ '
Small capacitor* are practically alvaya ueed aa components la other
electrical or electromechanical equipment. Typical examples of large
quantity uaaga of auch capacitors are in fluorescent lamp ballasts
and residential air conditioning equipment. Failure of such capacitors
may result in scrapping of the device of which it Is a part (as In a
fluorescent ballast), or replacement and scrapping of the Individual
capacitor (as In a room air conditioner). However,, the majority of such
capacitors do not fail In service, but are scrapped as a result of wearout
or obsolescence of the devices In which the capacitors are used as
components. Thus, the matter of- disposal is characterized by low
concentration of email quantities of askarcl throughout the country and
Indeed throughout the world. Fortunately, the nature of the devices
and equipment In which such capacitors are used, is such that they are
normally disposed of In dry landfills as a matter of convenience. Since
It la impractical at present to exercise any meaningful control over
disposition of the bulk of such devices and equipment, it la Imperative
that askarel used for Impregnating small capacitors be limited to the
recently Introduced grade which contains a minimum concentration (0.4Z
maximum) of the higher chlorinated (5 or more chlorine atoms per molecule)
components.
PART B Disposal of Liquid Wastes
All liquid wastes containing askarel or waste askarel Itself shall be
disposed of according to one of the following procedures:
:l
MOMS 098730
Page 14
Incineration: Facilities capable of incineration at temperatures of ^ od *c and having exhaust gas scrubbing equipment as a part
thereof shall be suitable for this prupose.
.
meet requirements these facilities shall/haua appeeual of the State In which located for such purpai
and shall control liquid and vapor effluents within the limits set
forth in this document.
A description of> and availability of these incineration facilities Is contained in Section VIII of this document.
Toxic and Hazardous Wests Disposal Sites: Certain landfill si tea have been classified by State and Federal Governments as suitable for the disposal of toxic and hazardous liquids. Where such approved sites exist they may be used for the disposal of liquid wastes described In this document.
The following guidelines shall be observed In the packaging and shipment of liquid
wastes for disposal.
.
1. Transportation to the Incineration facility should be In sealed containers which will prevent leakage and accidental loss of askarel to the environment.
2. Containers should be labeled as to contents and prscautlona relative to loss to the environment.
3. Containers used for this prupose should not be used for sny other msterlale or retired from service until they are completely cleaned. Any solvents used In cleaning these containers will be contaminated with askarel and should be disposed of according to the same procedures herein described. MONS 09B731
Page IS
PART C Disposal of Solid Waataa
Part A for Scrap Capacitors)
All solid waataa which have been saturated with askarel should ba
disposed of by the following procedure:
The saturated wastes shall be placed Into leek-proof containers _ meeting State requirements
and transported to a 6ats-appsved dry landfill slte/as described
In Part B of this Section. Alternatively, they can be disposed of
by Incineration In Stats approved facilities.
Solid absorbents used for spills can be disposed of uncontalned In the dry landfill site -- transport to the site shall be In closed containers. Alternatively, solid Incineration can ba used In accordance with Part B (see Section VTII for Services).
VII. LABELING Capacitor units vary greatly in size and in end use or application. Small capacitor units are frequently applied as a component of another piece of equipment such as a fluorescent lighting ballast, a roadway or area lighting luminaire, a motor, etc.
In such applications a label on the capacitor unit referencing approved disposal procedures would not normally be visible when the piece of equipment Is disposed of.
For the above reasons the method of relating disposal Instructions for small capacitors and large capacitors shall ba treated separately and In the following manner.
Small Units (Incorporating less than 2 pounds of aakarel)
HONS 098732
Definition
Small capacitors are defined as those which contain askaral In quantities
up to
two (2) pounds each and In which the free liquid does not
exceed about 0.4 pound. They are hermetically sealed In metallic cases.
Pag 16
Such capacitor* ar* applied aa a component of a larger piece of equipment. Attaching a label to auch equipment referencing this Guideline or deeeriblng dlapoaal procedure* would be of limited practical value. The amount of askarel Involved in dlapoaal of a single auch equipment, th* frequency of auch dlapoaal, th* localized concentration of askarel resulting from such failed equipments, and tha likelihood that the small capacitor Is still a sealed unit ar* factors suggesting minimum environmental affects. Therefore the appropriate labeling of small capacitor units or equipments In which they ars used Is not considered necessary.
Large Capacitor Units (Incorporating more then 2 pounds of askarel) Th* capacitor manufacturer should affix in a conspicuous placa a labal referencing thla document or describing disposal procedures consistent with It. This labal Is available from NIKA and will read as follows:
[ Us* Uniform Industry Label ] TO BE DESIGNED
NOTTCE This capacitor contains FCB'a. To avoid possible environmental contamination, It should ba disposed of only In dry landfill areae meeting State requirements or In approved Incineration sarvlcts.
Saa AMERICAN NATIONAL STANDARDS INSTITUTE GUIDELINE *
for Instructions.
MONS 098733