Document nNNDjEgkJEy9wEyJMx14kqrb1

inter Office Personnel and Organization Staff Mr. C. A. Mokaren, Manager Sheffield Aluminum Casting Plant August 23, 1976 cc J. W. Caden, M.D. E. B. Jeakle D. Jones T. P. Nugent Subject: Industrial Hygiene Study - "Kaowool" Products and Millboard and "Superex" Material In response to your request on July 20, 1976, the Industrial , Hygiene Section completed a study to evaluate employe exposures * to airborne particulate concentrations at the Sheffield Aluminum Casting Plant. The operation studied was the band saw cutting of insulating materials in Department 93 maintenance area. The results of this study and the instrumentation employed are attached. The results indicate that the airborne dust concentrations from the Kaowool Products, which do not contain asbestos, were well within the threshold limit value. However, the asbestos base materials being used at the present time show that the established standard is being exceeded. ms Attachments (2) * * kIf * * f i HFM-012833 Industrial Hygienist . Industrial Hygiene Section Employe Health Services Department 8005 0513 PROnnrpn pv cnpn SCF-FORD-1365 Discussion The pjrpose of this stjdy was to evaluate employe exposure to dust con centrations of the 'Kuowool" material!, and of the asbestos base materials used to line the glo bar furnaces. It vms established that ten minutes cutting time was necessvy for the lining of each glo bar furnace. Each of the referenced materials was cut for a ten-minute duration and samples were collected relative to each of the materials being processed. A breathing zone sampla as well as a related bulk sample for ecch of the "Kcowool" Products were sent to .-n outside laboratory to determine concen trations by count using contrast phase microscopy and analysis for c-sbestos and free silica using X-ray diffraction. A bulk sample of Master Insulating Cement was also submitted for analysis of asbestos and free silica. The results indicate -hat these materials are fibrous but not asbestiform materials and present no problem pertinent to this contaminant as well as to free silica exposure. The present state of industrial hygiene knowledge is that "Kaowool" is biologically inert when inhaled, however, experience has shown that it is a mistake to assume that any dust is completely totally inert. It would, therefore, be prudent to implement the following recommendations: 1. During extended periods of grinding or cutting of these products, the use of approved respiratory protection is advised. 2. Install an exhaust ventilation system on the band saw to meet with the specifications of the attached reference. 3. Locate the dust collector for the band saw outside the sawing area and be assured that the exhaust effluents cannot re-enter the building. Every effort should oe extended to eliminate the use of asbestos base materials in the plant. In conclusion, substitution of the BabcockWilcox products for asbestos will eliminate use of a material in the Sheffield Plant recognized to be an occupational health hazard subject to OSHA regulations. Nevertheless, the alternative materials will generate nuisance dust during sawing operations which should be exhaust ventilated as indicated on attached engineering specification sheets. HFM -012834 8005 0514 PROD! TPFD RY FOPTh I* il , 'V N0co0) Data Sheet - Sheffield Aluminum Casting Plant > 01 Kaowool Products Particgis&ubic ffoo^gg Air - OSHA 8 Hour Time-Weighted Average Breathing zone samples - Hr. J. Warren, SS #9510 a. Cutting Maronite XL board b. tl Kaowool HS It c. ' AL tt d. It " AL It e. Vt "M f - rigid one side Asbestos Simple Data Record # 20.0 CEP-86 CEP-87 CEP-88 CEP-89 CEP-90 0.3 0.5 0.5 1.8 1.2 Concentration of Fibers Greater than 5 Microns in length per Milliliter of Air OSHA Asbestos Fiber - Threshold Limit Value 8 Ilcur Tine-Weighted Average * t Ceiling Limit Cutting Millboard arid Superex Breathing zone sample - Mr. J. Warren, SS t/9510 General air top of welder's bench adjacent to collector " " sample, top of supervisor's desk " " " , block cutting saw CEP-91 CEP-92 CEP-93 CEP-94 2.0 10.0 6.5 2.2 5.5 0.2 P R O D T IfF n FtV P D P H Instrumentation: MSA Model G Pumps Flow rate 2.0 liters/minute Millipore Type AA membrane filters Analysis: Clayton Environmental Consultants - Ffnse contrast microscopy TO -------riJiytfln V AT -- 3&uttrfHeH.y Michigan Elae eeu^ler 37m for asbestos combine lncladlnc one blanh. Zicht stertfes bul!: tor analysis to ftsternlne pgrwnt esbertrT.. SIGNED DEPT OR LOCA TION cen l* dm j 7 5 ebonies Plasters DATE to--urn:-- HFM- 012836 8005 0516 ppnrT rrpn pv enpn Hr. H. Stephan Assistant Manager Plant Baginoerlag Fori of Europe 3hcorporate! August 9, 1976 Subject: Mae of Arfbestoe Products Tour letter to Mr. D. J. MeChesney of Nqy SO, 1976 has been referred to the Industrial hygiene offices for oonasat. Besuits of epdesdological studies oorrelating asbestos exposures and the Incidence of lung diseases Including bronchogenic carcinoma* mesothelioma* and aabestosis leave little doubt that excessive exposure to aSbestos is pathogenic. Over the last docade as core and acre evidence surfaced regarding the toxicity of asbestos* permissible exposure limits In the United States have been repeatedly reduced. She currant permissible exposure limit la the Uhltod States is 2 fibers per ct&ie centimeter (fibers greater than 5 microns In length) for d hours per day* 40 hours per week.* and It has bean proposed that the limit be further reduced to 0*9 fibers per cubic centimeter (fibers greater than 5 microns in length). Because of the health Implications which ney result Aron using asbestos* a complete evaluation of all operations using asbestos Including the impact to the oontnsasr resulting fron asbestos la any finished product Should be initiated. Zn order to permit an intelligent decision regarding the elimination or modifica tion of using asbestos In a particular operation* the following guidelines ere presented: 1. Always substitute less hazardous material for a more toxic substance whenever possible. IBiene are many alternate materials havin&^gfenllar properties to asbestos such as mineral wools* cliye, and diataaseeous earth v&ieh could be substituted for asbestos without reducing quality. It should be pointed out that While a substitute nay be less toxic than asbestos* It does not necessarily naan that it is nontoxic. 2. If asbestos oust be used* Institute engineering Changes so that affected employee are not excessively exposed. Engineering ebanges include* but are not limited to: a. Changing work practices b. Administrative rotation c. Equipment design changes d. Mechanical ventilation Including exhaust ventilation e. Modification of handling methods suaftx as using wet material handling 8005 0517 PPnTvnr'nr* v cnon HFM-012837 Hr. H. Stephan August 9, 197*5 3* A third alteznaitlw vtoieh Is not xeccmaended as a pomaaaat solution consists of providing the employe vlth personal protective devioes such as respirators end a dally change of outer clothing. She XJhltod States Government requires the following restrictions in addition to cavlronaaatal ocntsol la all asbestos operations. a. Periodic medical examinations h. Becord-koeplac requirements c. Employe training end notification of excessive exposures d. Periodic sampling (depending on degree of exposure) e. Waste disposal practioes f Warning sign requirements A oodblnation of the morel Obligation to protect the health and safety of the employe and meet present or proposed legislations In a given cotntxy vlll determine the impact using asbestos will have on a given operation. 2be goal of any operation is to produce quality results at the lowest possible prloe -without oonproadslng the health aid safety of the employes involved in the operation. Safety end quality are constants and the cost variable should be minimized by modifying ell other operation variables. Uhls office, ss well as all hygiene personnel vlthln Ford of Europe, vlll be happy to set up or review an asbestos control program. S3B/m Sheldon B. Bahinovitz Senior Industrial Ifygienist industrial fyglene Section Employe Health Services Department Central ifedlcal Services Building HFM -012838 8005 0518 PROnrirpn pv poph